20 resultados para Constant Loading Rate
em Universidad Politécnica de Madrid
Resumo:
While static fracture toughness is a widely studied and standardised parameter, its dynamic counterpart has not been exhaustively examined. Therefore, in this research a series of quasi-static and different loading-rate dynamic tests were carried out to determine the evolution of fracture toughness with the velocity of the application of the load on aluminium 7017-T73 alloy. Three-point bending tests of pre-fatigued standard specimens (ASTM E399) at four loading-rates were carried out. The experiments were conducted by employing the subsequent apparatus ordered from lowest to highest load application velocity: a servo-hydraulic universal testing machine, a free-drop tower, a modified Split Hopkinson Pressure Bar and an explosive load testing device. In order to perform the dynamic fracture toughness tests, it was necessary to design and develop some experimental devices. The fracture-initiation toughness of the aluminium 7017-T73 alloy did not exhibit a significant variation for the studied cases. As a conclusion, the research showed that fracture-initiation toughness remained constant regardless of the velocity at which the load was applied.
Resumo:
The thermal annealing of amorphous tracks of nanometer-size diameter generated in lithium niobate (LiNbO3) by Bromine ions at 45 MeV, i.e., in the electronic stopping regime, has been investigated by RBS/C spectrometry in the temperature range from 250°C to 350°C. Relatively low fluences have been used (<1012 cm−2) to produce isolated tracks. However, the possible effect of track overlapping has been investigated by varying the fluence between 3×1011 cm−2 and 1012 cm−2. The annealing process follows a two-step kinetics. In a first stage (I) the track radius decreases linearly with the annealing time. It obeys an Arrhenius-type dependence on annealing temperature with activation energy around 1.5 eV. The second stage (II) operates after the track radius has decreased down to around 2.5 nm and shows a much lower radial velocity. The data for stage I appear consistent with a solid-phase epitaxial process that yields a constant recrystallization rate at the amorphous-crystalline boundary. HRTEM has been used to monitor the existence and the size of the annealed isolated tracks in the second stage. On the other hand, the thermal annealing of homogeneous (buried) amorphous layers has been investigated within the same temperature range, on samples irradiated with Fluorine at 20 MeV and fluences of ∼1014 cm−2. Optical techniques are very suitable for this case and have been used to monitor the recrystallization of the layers. The annealing process induces a displacement of the crystalline-amorphous boundary that is also linear with annealing time, and the recrystallization rates are consistent with those measured for tracks. The comparison of these data with those previously obtained for the heavily damaged (amorphous) layers produced by elastic nuclear collisions is summarily discussed.
Resumo:
RESUMEN La dispersión del amoniaco (NH3) emitido por fuentes agrícolas en medias distancias, y su posterior deposición en el suelo y la vegetación, pueden llevar a la degradación de ecosistemas vulnerables y a la acidificación de los suelos. La deposición de NH3 suele ser mayor junto a la fuente emisora, por lo que los impactos negativos de dichas emisiones son generalmente mayores en esas zonas. Bajo la legislación comunitaria, varios estados miembros emplean modelos de dispersión inversa para estimar los impactos de las emisiones en las proximidades de las zonas naturales de especial conservación. Una revisión reciente de métodos para evaluar impactos de NH3 en distancias medias recomendaba la comparación de diferentes modelos para identificar diferencias importantes entre los métodos empleados por los distintos países de la UE. En base a esta recomendación, esta tesis doctoral compara y evalúa las predicciones de las concentraciones atmosféricas de NH3 de varios modelos bajo condiciones, tanto reales como hipotéticas, que plantean un potencial impacto sobre ecosistemas (incluidos aquellos bajo condiciones de clima Mediterráneo). En este sentido, se procedió además a la comparación y evaluación de varias técnicas de modelización inversa para inferir emisiones de NH3. Finalmente, se ha desarrollado un modelo matemático simple para calcular las concentraciones de NH3 y la velocidad de deposición de NH3 en ecosistemas vulnerables cercanos a una fuente emisora. La comparativa de modelos supuso la evaluación de cuatro modelos de dispersión (ADMS 4.1; AERMOD v07026; OPS-st v3.0.3 y LADD v2010) en un amplio rango de casos hipotéticos (dispersión de NH3 procedente de distintos tipos de fuentes agrícolas de emisión). La menor diferencia entre las concentraciones medias estimadas por los distintos modelos se obtuvo para escenarios simples. La convergencia entre las predicciones de los modelos fue mínima para el escenario relativo a la dispersión de NH3 procedente de un establo ventilado mecánicamente. En este caso, el modelo ADMS predijo concentraciones significativamente menores que los otros modelos. Una explicación de estas diferencias podríamos encontrarla en la interacción de diferentes “penachos” y “capas límite” durante el proceso de parametrización. Los cuatro modelos de dispersión fueron empleados para dos casos reales de dispersión de NH3: una granja de cerdos en Falster (Dinamarca) y otra en Carolina del Norte (EEUU). Las concentraciones medias anuales estimadas por los modelos fueron similares para el caso americano (emisión de granjas ventiladas de forma natural y balsa de purines). La comparación de las predicciones de los modelos con concentraciones medias anuales medidas in situ, así como la aplicación de los criterios establecidos para la aceptación estadística de los modelos, permitió concluir que los cuatro modelos se comportaron aceptablemente para este escenario. No ocurrió lo mismo en el caso danés (nave ventilada mecánicamente), en donde el modelo LADD no dio buenos resultados debido a la ausencia de procesos de “sobreelevacion de penacho” (plume-rise). Los modelos de dispersión dan a menudo pobres resultados en condiciones de baja velocidad de viento debido a que la teoría de dispersión en la que se basan no es aplicable en estas condiciones. En situaciones de frecuente descenso en la velocidad del viento, la actual guía de modelización propone usar un modelo que sea eficaz bajo dichas condiciones, máxime cuando se realice una valoración que tenga como objeto establecer una política de regularización. Esto puede no ser siempre posible debido a datos meteorológicos insuficientes, en cuyo caso la única opción sería utilizar un modelo más común, como la versión avanzada de los modelos Gausianos ADMS o AERMOD. Con el objetivo de evaluar la idoneidad de estos modelos para condiciones de bajas velocidades de viento, ambos modelos fueron utilizados en un caso con condiciones Mediterráneas. Lo que supone sucesivos periodos de baja velocidad del viento. El estudio se centró en la dispersión de NH3 procedente de una granja de cerdos en Segovia (España central). Para ello la concentración de NH3 media mensual fue medida en 21 localizaciones en torno a la granja. Se realizaron también medidas de concentración de alta resolución en una única localización durante una campaña de una semana. En este caso, se evaluaron dos estrategias para mejorar la respuesta del modelo ante bajas velocidades del viento. La primera se basó en “no zero wind” (NZW), que sustituyó periodos de calma con el mínimo límite de velocidad del viento y “accumulated calm emissions” (ACE), que forzaban al modelo a calcular las emisiones totales en un periodo de calma y la siguiente hora de no-calma. Debido a las importantes incertidumbres en los datos de entrada del modelo (inputs) (tasa de emisión de NH3, velocidad de salida de la fuente, parámetros de la capa límite, etc.), se utilizó el mismo caso para evaluar la incertidumbre en la predicción del modelo y valorar como dicha incertidumbre puede ser considerada en evaluaciones del modelo. Un modelo dinámico de emisión, modificado para el caso de clima Mediterráneo, fue empleado para estimar la variabilidad temporal en las emisiones de NH3. Así mismo, se realizó una comparativa utilizando las emisiones dinámicas y la tasa constante de emisión. La incertidumbre predicha asociada a la incertidumbre de los inputs fue de 67-98% del valor medio para el modelo ADMS y entre 53-83% del valor medio para AERMOD. La mayoría de esta incertidumbre se debió a la incertidumbre del ratio de emisión en la fuente (50%), seguida por la de las condiciones meteorológicas (10-20%) y aquella asociada a las velocidades de salida (5-10%). El modelo AERMOD predijo mayores concentraciones que ADMS y existieron más simulaciones que alcanzaron los criterios de aceptabilidad cuando se compararon las predicciones con las concentraciones medias anuales medidas. Sin embargo, las predicciones del modelo ADMS se correlacionaron espacialmente mejor con las mediciones. El uso de valores dinámicos de emisión estimados mejoró el comportamiento de ADMS, haciendo empeorar el de AERMOD. La aplicación de estrategias destinadas a mejorar el comportamiento de este último tuvo efectos contradictorios similares. Con el objeto de comparar distintas técnicas de modelización inversa, varios modelos (ADMS, LADD y WindTrax) fueron empleados para un caso no agrícola, una colonia de pingüinos en la Antártida. Este caso fue empleado para el estudio debido a que suponía la oportunidad de obtener el primer factor de emisión experimental para una colonia de pingüinos antárticos. Además las condiciones eran propicias desde el punto de vista de la casi total ausencia de concentraciones ambiente (background). Tras el trabajo de modelización existió una concordancia suficiente entre las estimaciones obtenidas por los tres modelos. De este modo se pudo definir un factor de emisión de para la colonia de 1.23 g NH3 por pareja criadora por día (con un rango de incertidumbre de 0.8-2.54 g NH3 por pareja criadora por día). Posteriores aplicaciones de técnicas de modelización inversa para casos agrícolas mostraron también un buen compromiso estadístico entre las emisiones estimadas por los distintos modelos. Con todo ello, es posible concluir que la modelización inversa es una técnica robusta para estimar tasas de emisión de NH3. Modelos de selección (screening) permiten obtener una rápida y aproximada estimación de los impactos medioambientales, siendo una herramienta útil para evaluaciones de impactos en tanto que permite eliminar casos que presentan un riesgo potencial de daño bajo. De esta forma, lo recursos del modelo pueden Resumen (Castellano) destinarse a casos en donde la posibilidad de daño es mayor. El modelo de Cálculo Simple de los Límites de Impacto de Amoniaco (SCAIL) se desarrolló para obtener una estimación de la concentración media de NH3 y de la tasa de deposición seca asociadas a una fuente agrícola. Está técnica de selección, basada en el modelo LADD, fue evaluada y calibrada con diferentes bases de datos y, finalmente, validada utilizando medidas independientes de concentraciones realizadas cerca de las fuentes. En general SCAIL dio buenos resultados de acuerdo a los criterios estadísticos establecidos. Este trabajo ha permitido definir situaciones en las que las concentraciones predichas por modelos de dispersión son similares, frente a otras en las que las predicciones difieren notablemente entre modelos. Algunos modelos nos están diseñados para simular determinados escenarios en tanto que no incluyen procesos relevantes o están más allá de los límites de su aplicabilidad. Un ejemplo es el modelo LADD que no es aplicable en fuentes con velocidad de salida significativa debido a que no incluye una parametrización de sobreelevacion del penacho. La evaluación de un esquema simple combinando la sobreelevacion del penacho y una turbulencia aumentada en la fuente mejoró el comportamiento del modelo. Sin embargo más pruebas son necesarias para avanzar en este sentido. Incluso modelos que son aplicables y que incluyen los procesos relevantes no siempre dan similares predicciones. Siendo las razones de esto aún desconocidas. Por ejemplo, AERMOD predice mayores concentraciones que ADMS para dispersión de NH3 procedente de naves de ganado ventiladas mecánicamente. Existe evidencia que sugiere que el modelo ADMS infraestima concentraciones en estas situaciones debido a un elevado límite de velocidad de viento. Por el contrario, existen evidencias de que AERMOD sobreestima concentraciones debido a sobreestimaciones a bajas Resumen (Castellano) velocidades de viento. Sin embrago, una modificación simple del pre-procesador meteorológico parece mejorar notablemente el comportamiento del modelo. Es de gran importancia que estas diferencias entre las predicciones de los modelos sean consideradas en los procesos de evaluación regulada por los organismos competentes. Esto puede ser realizado mediante la aplicación del modelo más útil para cada caso o, mejor aún, mediante modelos múltiples o híbridos. ABSTRACT Short-range atmospheric dispersion of ammonia (NH3) emitted by agricultural sources and its subsequent deposition to soil and vegetation can lead to the degradation of sensitive ecosystems and acidification of the soil. Atmospheric concentrations and dry deposition rates of NH3 are generally highest near the emission source and so environmental impacts to sensitive ecosystems are often largest at these locations. Under European legislation, several member states use short-range atmospheric dispersion models to estimate the impact of ammonia emissions on nearby designated nature conservation sites. A recent review of assessment methods for short-range impacts of NH3 recommended an intercomparison of the different models to identify whether there are notable differences to the assessment approaches used in different European countries. Based on this recommendation, this thesis compares and evaluates the atmospheric concentration predictions of several models used in these impact assessments for various real and hypothetical scenarios, including Mediterranean meteorological conditions. In addition, various inverse dispersion modelling techniques for the estimation of NH3 emissions rates are also compared and evaluated and a simple screening model to calculate the NH3 concentration and dry deposition rate at a sensitive ecosystem located close to an NH3 source was developed. The model intercomparison evaluated four atmospheric dispersion models (ADMS 4.1; AERMOD v07026; OPS-st v3.0.3 and LADD v2010) for a range of hypothetical case studies representing the atmospheric dispersion from several agricultural NH3 source types. The best agreement between the mean annual concentration predictions of the models was found for simple scenarios with area and volume sources. The agreement between the predictions of the models was worst for the scenario representing the dispersion from a mechanically ventilated livestock house, for which ADMS predicted significantly smaller concentrations than the other models. The reason for these differences appears to be due to the interaction of different plume-rise and boundary layer parameterisations. All four dispersion models were applied to two real case studies of dispersion of NH3 from pig farms in Falster (Denmark) and North Carolina (USA). The mean annual concentration predictions of the models were similar for the USA case study (emissions from naturally ventilated pig houses and a slurry lagoon). The comparison of model predictions with mean annual measured concentrations and the application of established statistical model acceptability criteria concluded that all four models performed acceptably for this case study. This was not the case for the Danish case study (mechanically ventilated pig house) for which the LADD model did not perform acceptably due to the lack of plume-rise processes in the model. Regulatory dispersion models often perform poorly in low wind speed conditions due to the model dispersion theory being inapplicable at low wind speeds. For situations with frequent low wind speed periods, current modelling guidance for regulatory assessments is to use a model that can handle these conditions in an acceptable way. This may not always be possible due to insufficient meteorological data and so the only option may be to carry out the assessment using a more common regulatory model, such as the advanced Gaussian models ADMS or AERMOD. In order to assess the suitability of these models for low wind conditions, they were applied to a Mediterranean case study that included many periods of low wind speed. The case study was the dispersion of NH3 emitted by a pig farm in Segovia, Central Spain, for which mean monthly atmospheric NH3 concentration measurements were made at 21 locations surrounding the farm as well as high-temporal-resolution concentration measurements at one location during a one-week campaign. Two strategies to improve the model performance for low wind speed conditions were tested. These were ‘no zero wind’ (NZW), which replaced calm periods with the minimum threshold wind speed of the model and ‘accumulated calm emissions’ (ACE), which forced the model to emit the total emissions during a calm period during the first subsequent non-calm hour. Due to large uncertainties in the model input data (NH3 emission rates, source exit velocities, boundary layer parameters), the case study was also used to assess model prediction uncertainty and assess how this uncertainty can be taken into account in model evaluations. A dynamic emission model modified for the Mediterranean climate was used to estimate the temporal variability in NH3 emission rates and a comparison was made between the simulations using the dynamic emissions and a constant emission rate. Prediction uncertainty due to model input uncertainty was 67-98% of the mean value for ADMS and between 53-83% of the mean value for AERMOD. Most of this uncertainty was due to source emission rate uncertainty (~50%), followed by uncertainty in the meteorological conditions (~10-20%) and uncertainty in exit velocities (~5-10%). AERMOD predicted higher concentrations than ADMS and more of the simulations met the model acceptability criteria when compared with the annual mean measured concentrations. However, the ADMS predictions were better correlated spatially with the measurements. The use of dynamic emission estimates improved the performance of ADMS but worsened the performance of AERMOD and the application of strategies to improved model performance had similar contradictory effects. In order to compare different inverse modelling techniques, several models (ADMS, LADD and WindTrax) were applied to a non-agricultural case study of a penguin colony in Antarctica. This case study was used since it gave the opportunity to provide the first experimentally-derived emission factor for an Antarctic penguin colony and also had the advantage of negligible background concentrations. There was sufficient agreement between the emission estimates obtained from the three models to define an emission factor for the penguin colony (1.23 g NH3 per breeding pair per day with an uncertainty range of 0.8-2.54 g NH3 per breeding pair per day). This emission estimate compared favourably to the value obtained using a simple micrometeorological technique (aerodynamic gradient) of 0.98 g ammonia per breeding pair per day (95% confidence interval: 0.2-2.4 g ammonia per breeding pair per day). Further application of the inverse modelling techniques for a range of agricultural case studies also demonstrated good agreement between the emission estimates. It is concluded, therefore, that inverse dispersion modelling is a robust technique for estimating NH3 emission rates. Screening models that can provide a quick and approximate estimate of environmental impacts are a useful tool for impact assessments because they can be used to filter out cases that potentially have a minimal environmental impact allowing resources to be focussed on more potentially damaging cases. The Simple Calculation of Ammonia Impact Limits (SCAIL) model was developed as a screening model to provide an estimate of the mean NH3 concentration and dry deposition rate downwind of an agricultural source. This screening tool, based on the LADD model, was evaluated and calibrated with several experimental datasets and then validated using independent concentration measurements made near sources. Overall SCAIL performed acceptably according to established statistical criteria. This work has identified situations where the concentration predictions of dispersion models are similar and other situations where the predictions are significantly different. Some models are simply not designed to simulate certain scenarios since they do not include the relevant processes or are beyond the limits of their applicability. An example is the LADD model that is not applicable to sources with significant exit velocity since the model does not include a plume-rise parameterisation. The testing of a simple scheme combining a momentum-driven plume rise and increased turbulence at the source improved model performance, but more testing is required. Even models that are applicable and include the relevant process do not always give similar predictions and the reasons for this need to be investigated. AERMOD for example predicts higher concentrations than ADMS for dispersion from mechanically ventilated livestock housing. There is evidence to suggest that ADMS underestimates concentrations in these situations due to a high wind speed threshold. Conversely, there is also evidence that AERMOD overestimates concentrations in these situations due to overestimation at low wind speeds. However, a simple modification to the meteorological pre-processor appears to improve the performance of the model. It is important that these differences between the predictions of these models are taken into account in regulatory assessments. This can be done by applying the most suitable model for the assessment in question or, better still, using multiple or hybrid models.
Resumo:
In pressure irrigation-water distribution networks, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of flow rate. In addition, applied water volume is used controlled operating the valve during a calculated time interval, and assuming constant flow rate. In general, a pressure regulating valve PRV is the commonly used pressure regulating device in a hydrant, which, also, executes the open and close function. A hydrant feeds several irrigation units, requiring a wide range in flow rate. In addition, some flow meters are also available, one as a component of the hydrant and the rest are placed downstream. Every land owner has one flow meter for each group of field plots downstream the hydrant. Its lecture could be used for refining the water balance but its accuracy must be taken into account. Ideal PRV performance would maintain a constant downstream pressure. However, the true performance depends on both upstream pressure and the discharged flow rate. The objective of this work is to asses the influence of the performance on the applied volume during the whole irrigation events in a year. The results of the study have been obtained introducing the flow rate into a PRV model. Variations on flow rate are simulated by taking into account the consequences of variations on climate conditions and also decisions in irrigation operation, such us duration and frequency application. The model comprises continuity, dynamic and energy equations of the components of the PRV.
Resumo:
A numerical description is given for the pulsating emission of droplets from an electrified meniscus of an inviscid liquid of infinite electrical conductivity which is injected at a constant flow rate into a region of uniform, continuous or time periodic, electric field. Under a continuous field, the meniscus attains a periodic regime in which bursts of tiny droplets are emitted from its tip. At low electric fields this regime consists of sequences of emission bursts interspersed with sequences of meniscus oscillations without droplet emission, while at higher fields the bursts occur periodically. These results are in qualitative agreement with experimental results in the literature. Under a time periodic electric field with square waveform, the electric stress that acts on the surface of the liquid while the field is on may generate a tip that emits tiny droplets or may accelerate part of the meniscus and lead to a second emission mode in which a few large droplets are emitted after the electric field is turned off. Conditions under which each emission mode or a combination of the two are realized are discussed for low frequency oscillatory fields. A simplified model is proposed for high electric field frequencies, of the order of the capillary frequency of the meniscus. This model allows computing the average emission rate as a function of the amplitude, duration and bias of the electric field square wave, and shows that droplet emission fails to follow the applied field above a certain frequency
Resumo:
The effect of the applied stress on the deformation and crack nucleation and propagation mechanisms of a c-TiAl intermetallic alloy (Ti-45Al-2Nb-2Mn (at. pct)-0.8 vol. pct TiB2) was examined by means of in situ tensile (constant strain rate) and tensile-creep (constant load) experiments performed at 973 K (700 �C) using a scanning electron microscope. Colony boundary cracking developed during the secondary stage in creep tests at 300 and 400 MPa and during the tertiary stage of the creep tests performed at higher stresses. Colony boundary cracking was also observed in the constant strain rate tensile test. Interlamellar ledges were only found during the tensile-creep tests at high stresses (r>400 MPa) and during the constant strain rate tensile test. Quantitative measurements of the nature of the crack propagation path along secondary cracks and along the primary crack indicated that colony boundaries were preferential sites for crack propagation under all the conditions investigated. The frequency of interlamellar cracking increased with stress, but this fracture mechanism was always of secondary importance. Translamellar cracking was only observed along the primary crack.
Resumo:
La presente tesis es un estudio analítico y numérico del electrospray. En la configuración más sencilla, un caudal constante del líquido a atomizar, que debe tener una cierta conductividad eléctrica, se inyecta en un medio dieléctrico (un gas u otro líquido inmiscible con el primero) a través de un tubo capilar metálico. Entre este tubo y un electrodo lejano se aplica un voltaje continuo que origina un campo eléctrico en el líquido conductor y en el espacio que lo rodea. El campo eléctrico induce una corriente eléctrica en el líquido, que acumula carga en su superficie, y da lugar a un esfuerzo eléctrico sobre la superficie, que tiende a alargarla en la dirección del campo eléctrico. El líquido forma un menisco en el extremo del tubo capilar cuando el campo eléctrico es suficientemente intenso y el caudal suficientemente pequeño. Las variaciones de presión y los esfuerzos viscosos asociados al movimiento del líquido son despreciables en la mayor parte de este menisco, siendo dominantes los esfuerzos eléctrico y de tensión superficial que actúan sobre la superficie del líquido. En el modo de funcionamiento llamado de conochorro, el balance de estos esfuerzos hace que el menisco adopte una forma cónica (el cono de Taylor) en una región intermedia entre el extremo del tubo y la punta del menisco. La velocidad del líquido aumenta al acercarse al vértice del cono, lo cual propicia que las variaciones de la presión en el líquido generadas por la inercia o por la viscosidad entren en juego, desequilibrando el balance de esfuerzos mencionado antes. Como consecuencia, del vértice del cono sale un delgado chorro de líquido, que transporta la carga eléctrica que se acumula en la superficie. La acción del campo eléctrico tangente a la superficie sobre esta carga origina una tracción eléctrica que tiende a alargar el chorro. Esta tracción no es relevante en el menisco, donde el campo eléctrico tangente a la superficie es muy pequeño, pero se hace importante en el chorro, donde es la causa del movimiento del líquido. Lejos del cono, el chorro puede o bien desarrollar una inestabilidad asimétrica que lo transforma en una espiral (whipping) o bien romperse en un spray de gotas prácticamente monodispersas cargadas eléctricamente. La corriente eléctrica transportada por el líquido es la suma de la corriente de conducción en el interior del líquido y la corriente debida a la convección de la carga acumulada en su superficie. La primera domina en el menisco y la segunda en el chorro lejano, mientras que las dos son comparables en una región intermedia de transferencia de corriente situada al comienzo del chorro aunque aguas abajo de la región de transición cono-chorro, en la que el menisco deja de ser un cono de Taylor. Para un campo exterior dado, la acumulación de carga eléctrica en la superficie del líquido reduce el campo eléctrico en el interior del mismo, que llega a anularse cuando la carga alcanza un estado final de equilibrio. El tiempo característico de este proceso es el tiempo de relajación dieléctrica, que es una propiedad del líquido. Cuando el tiempo de residencia del líquido en la región de transición cono-chorro (o en otra región del campo fluido) es grande frente al tiempo de relajación dieléctrica, la carga superficial sigue una sucesión de estados de equilibrio y apantalla al líquido del campo exterior. Cuando esta condición deja de cumplirse, aparecen efectos de relajación de carga, que se traducen en que el campo exterior penetra en el líquido, a no ser que su constante dieléctrica sea muy alta, en cuyo caso el campo inducido por la carga de polarización evita la entrada del campo exterior en el menisco y en una cierta región del chorro. La carga eléctrica en equilibrio en la superficie de un menisco cónico intensifica el campo eléctrico y determina su variación espacial hasta distancias aguas abajo del menisco del orden de su tamaño. Este campo, calculado por Taylor, es independiente del voltaje aplicado, por lo que las condiciones locales del flujo y el valor de la corriente eléctrica son también independientes del voltaje en tanto los tamaños de las regiones que determinan estas propiedades sean pequeños frente al tamaño del menisco. Los resultados experimentales publicados en la literatura muestran que existe un caudal mínimo para el que el modo cono-chorro que acabamos de describir deja de existir. El valor medio y la desviación típica de la distribución de tamaños de las gotas generadas por un electrospray son mínimos cuando se opera cerca del caudal mínimo. A pesar de que los mecanismos responsables del caudal mínimo han sido muy estudiados, no hay aún una teoría completa del mismo, si bien su existencia parece estar ligada a la aparición de efectos de relajación de carga en la región de transición cono-chorro. En esta tesis, se presentan estimaciones de orden de magnitud, algunas existentes y otras nuevas, que muestran los balances dominantes responsables de las distintas regiones de la estructura asintótica de la solución en varios casos de interés. Cuando la inercia del líquido juega un papel en la transición cono-chorro, los resultados muestran que la región de transferencia de corriente, donde la mayor parte de la corriente pasa a la superficie, está en el chorro aguas abajo de la región de transición cono-chorro. Los efectos de relajación de carga aparecen de forma simultánea en el chorro y la región de transición cuando el caudal se disminuye hasta valores de un cierto orden. Para caudales aún menores, los efectos de relajación de carga se notan en el menisco, en una región grande comparada con la de transición cono-chorro. Cuando el efecto de las fuerzas de viscosidad es dominante en la región de transición, la región de transferencia de corriente está en el chorro pero muy próxima a la región de transición cono-chorro. Al ir disminuyendo el caudal, los efectos de relajación de carga aparecen progresivamente en el chorro, en la región de transición y por último en el menisco. Cuando el caudal es mucho mayor que el mínimo del modo cono-chorro, el menisco deja de ser cónico. El campo eléctrico debido al voltaje aplicado domina en la región de transferencia de corriente, y tanto la corriente eléctrica como el tamaño de las diferentes regiones del problema pasan a depender del voltaje aplicado. Como resultado de esta dependencia, el plano caudal-voltaje se divide en diferentes regiones que se analizan separadamente. Para caudales suficientemente grandes, la inercia del líquido termina dominando frente a las fuerzas de la viscosidad. Estos resultados teóricos se han validado con simulaciones numéricas. Para ello se ha formulado un modelo simplificado del flujo, el campo eléctrico y el transporte de carga en el menisco y el chorro del electrospray. El movimiento del líquido se supone casi unidireccional y se describe usando la aproximación de Cosserat para un chorro esbelto. Esta aproximación, ampliamente usada en la literatura, permite simular con relativa facilidad múltiples casos y cubrir amplios rangos de valores de los parámetros reteniendo los efectos de la viscosidad y la inercia del líquido. Los campos eléctricos dentro y fuera del liquido están acoplados y se calculan sin simplificación alguna usando un método de elementos de contorno. La solución estacionaria del problema se calcula mediante un método iterativo. Para explorar el espacio de los parámetros, se comienza calculando una solución para valores fijos de las propiedades del líquido, el voltaje aplicado y el caudal. A continuación, se usa un método de continuación que permite delinear la frontera del dominio de existencia del modo cono-chorro, donde el método iterativo deja de converger. Cuando el efecto de la inercia del líquido domina en la región de transición cono-chorro, el caudal mínimo para el cual el método iterativo deja de converger es del orden del valor estimado del caudal para el que comienza a haber efectos de relajación de carga en el chorro y el cono. Aunque las simulaciones no convergen por debajo de dicho caudal, el valor de la corriente eléctrica para valores del caudal ligeramente mayores parece ajustarse a las estimaciones para caudales menores, reflejando un posible cambio en los balances aplicables. Por el contrario, cuando las fuerzas viscosas dominan en la región de transición, se pueden obtener soluciones estacionarias para caudales bastante menores que aquel para el que aparecen efectos de relajación de carga en la región de transición cono-chorro. Los resultados numéricos obtenidos para estos pequeños caudales se ajustan perfectamente a las estimaciones de orden de magnitud que se describen en la memoria. Por último, se incluyen como anexos dos estudios teóricos que han surgido de forma natural durante el desarrollo de la tesis. El primero hace referencia a la singularidad en el campo eléctrico que aparece en la línea de contacto entre el líquido y el tubo capilar en la mayoría de las simulaciones. Primero se estudia en qué situaciones el campo eléctrico tiende a infinito en la línea de contacto. Después, se comprueba que dicha singularidad no supone un fallo en la descripción del problema y que además no afecta a la solución lejos de la línea de contacto. También se analiza si los esfuerzos eléctricos infinitamente grandes a los que da lugar dicha singularidad pueden ser compensados por el resto de esfuerzos que actúan en la superficie del líquido. El segundo estudio busca determinar el tamaño de la región de apantallamiento en un chorro de líquido dieléctrico sin carga superficial. En esta región, el campo exterior es compensado parcialmente por el campo que induce la carga de polarización en la superficie del líquido, de forma que en el interior del líquido el campo eléctrico es mucho menor que en el exterior. Una región como ésta aparece en las estimaciones cuando los efectos de relajación de carga son importantes en la región de transferencia de corriente en el chorro. ABSTRACT This aim of this dissertation is a theoretical and numerical analysis of an electrospray. In its most simple configuration, a constant flow rate of the liquid to be atomized, which has to be an electrical conductor, is injected into a dielectric medium (a gas or another inmiscible fluid) through a metallic capillary tube. A constant voltage is applied between this tube and a distant electrode that produces an electric field in the liquid and the surrounding medium. This electric field induces an electric current in the liquid that accumulates charge at its surface and leads to electric stresses that stretch the surface in the direction of the electric field. A meniscus appears on the end of the capillary tube when the electric field is sufficiently high and the flow rate is small. Pressure variations and viscous stresses due to the motion of the liquid are negligible in most of the meniscus, where normal electric and surface tension stresses acting on the surface are dominant. In the so-called cone-jet mode, the balance of these stresses forces the surface to adopt a conical shape -Taylor cone- in a intermediate region between the end of the tube and the tip of the meniscus. When approaching the cone apex, the velocity of the liquid increases and leads to pressure variations that eventually disturb the balance of surfaces tension and electric stresses. A thin jet emerges then from the tip of the meniscus that transports the charge accumulated at its surface. The electric field tangent to the surface of the jet acts on this charge and continuously stretches the jet. This electric force is negligible in the meniscus, where the component of the electric field tangent to the surface is small, but becomes very important in the jet. Far from the cone, the jet can either develop an asymmetrical instability named “whipping”, whereby the jet winds into a spiral, or break into a spray of small, nearly monodisperse, charged droplets. The electric current transported by the liquid has two components, the conduction current in the bulk of the liquid and the convection current due to the transport of the surface charge by the flow. The first component dominates in the meniscus, the second one in the far jet, and both are comparable in a current transfer region located in the jet downstream of the cone-jet transition region where the meniscus ceases to be a Taylor cone. Given an external electric field, the charge that accumulates at the surface of the liquid reduces the electric field inside the liquid, until an equilibrium is reached in which the electric field induced by the surface charge counters the external electric field and shields the liquid from this field. The characteristic time of this process is the electric relaxation time, which is a property of the liquid. When the residence time of the liquid in the cone-jet transition region (or in other region of the flow) is greater than the electric relaxation time, the surface charge follows a succession of equilibrium states and continuously shield the liquid from the external field. When this condition is not satisfied, charge relaxation effects appear and the external field penetrates into the liquid unless the liquid permittivity is large. For very polar liquids, the field due to the polarization charge at the surface prevents the external field from entering the liquid in the cone and in certain region of the jet. The charge at the surface of a conical meniscus intensifies the electric field around the cone, determining its spatial variation up to distances downstream of the apex of the order of the size of the meniscus. This electric field, first computed by Taylor, is independent of the applied voltage. Therefore local flow characteristics and the electric current carried by the jet are also independent of the applied voltage provided the size of the regions that determine these magnitudes are small compared with the size of the meniscus. Many experiments in the literature show the existence of a minimum flow rate below which the cone-jet mode cannot be established. The mean value and the standard deviation of the electrospray droplet size distribution are minimum when the device is operated near the minimum flow rate. There is no complete explanation of the minimum flow rate, even though possible mechanisms have been extensively studied. The existence of a minimum flow rate seems to be connected with the appearance of charge relaxation effects in the transition region. In this dissertation, order of magnitude estimations are worked out that show the dominant balances in the different regions of the asymptotic structure of the solution for different conditions of interest. When the inertia of the liquid plays a role in the cone-jet transition region, the region where most of the electric current is transfered to the surface lies in the jet downstream the cone-jet transition region. When the flow rate decreases to a certain value, charge relaxation effects appear simultaneously in the jet and in the transition region. For smaller values of the flow rate, charge relaxation effects are important in a region of the meniscus larger than the transition region. When viscous forces dominate in the flow in the cone-jet transition region, the current transfer region is located in the jet immediately after the transition region. When flow rate is decreased, charge relaxation effects appears gradually, first in the jet, then in the transition region, and finally in the meniscus. When flow rate is much larger than the cone-jet mode minimum, the meniscus ceases to be a cone. The electric current and the structure of the solution begin to depend on the applied voltage. The flow rate-voltage plane splits into different regions that are analyzed separately. For sufficiently large flow rates, the effect of the inertia of the liquid always becomes greater than the effect of the viscous forces. A set of numerical simulations have been carried out in order to validate the theoretical results. A simplified model of the problem has been devised to compute the flow, the electric field and the surface charge in the meniscus and the jet of an electrospray. The motion of the liquid is assumed to be quasi-unidirectional and described by Cosserat’s approximation for a slender jet. This widely used approximation allows to easily compute multiple configurations and to explore wide ranges of values of the governing parameters, retaining the effects of the viscosity and the inertia of the liquid. Electric fields inside and outside the liquid are coupled and are computed without any simplification using a boundary elements method. The stationary solution of the problem is obtained by means of an iterative method. To explore the parameter space, a solution is first computed for a set of values of the liquid properties, the flow rate and the applied voltage, an then a continuation method is used to find the boundaries of the cone-jet mode domain of existence, where the iterative method ceases to converge. When the inertia of the liquid dominates in the cone-jet transition region, the iterative method ceases to converge for values of the flow rate for which order-of-magnitude estimates first predict charge relaxation effects to be important in the cone and the jet. The electric current computed for values of the flow rate slightly above the minimum for which convergence is obtained seems to agree with estimates worked out for lower flow rates. When viscous forces dominate in the transition region, stationary solutions can be obtained for flow rates significantly smaller than the one for which charge relaxation effects first appear in the transition region. Numerical results obtained for those small values of the flow rate agree with our order of magnitude estimates. Theoretical analyses of two issues that have arisen naturally during the thesis are summarized in two appendices. The first appendix contains a study of the singularity of the electric field that most of the simulations show at the contact line between the liquid and the capillary tube. The electric field near the contact line is analyzed to determine the ranges of geometrical configurations and liquid permittivity where a singularity appears. Further estimates show that this singularity does not entail a failure in the description of the problem and does not affect the solution far from the contact line. The infinite electric stresses that appear at the contact line can be effectively balanced by surface tension. The second appendix contains an analysis of the size and slenderness of the shielded region of a dielectric liquid in the absence of free surface charge. In this region, the external electric field is partially offset by the polarization charge so that the inner electric field is much lower than the outer one. A similar region appears in the estimates when charge relaxation effects are important in the current transfer region.
Resumo:
This work aims to contribute to a further understanding of the fundamentals of crystallographic slip and grain boundary sliding in the γ-TiAl Ti–45Al–2Nb–2Mn (at%)–0.8 vol%TiB2 intermetallic alloy, by means of in situ high-temperature tensile testing combined with electron backscatter diffraction (EBSD). Several microstructures, containing different fractions and sizes of lamellar colonies and equiaxed γ-grains, were fabricated by either centrifugal casting or powder metallurgy, followed by heat treatment at 1300 °C and furnace cooling. in situ tensile and tensile-creep experiments were performed in a scanning electron microscope (SEM) at temperatures ranging from 580 °C to 700 °C. EBSD was carried out in selected regions before and after straining. Our results suggest that, during constant strain rate tests, true twin γ/γ interfaces are the weakest barriers to dislocations and, thus, that the relevant length scale might be influenced by the distance between non-true twin boundaries. Under creep conditions both grain/colony boundary sliding (G/CBS) and crystallographic slip are observed to contribute to deformation. The incidence of boundary sliding is particularly high in γ grains of duplex microstructures. The slip activity during creep deformation in different microstructures was evaluated by trace analysis. Special emphasis was placed in distinguishing the compliance of different slip events with the Schmid law with respect to the applied stress.
Resumo:
La nitrificación-desnitrificación es el proceso biológico tradicional para la remoción de nitrógeno de las aguas residuales (Ruiz G. et al., 2006a), siendo fundamental ya que contribuye a controlar la eutroficación de los cuerpos receptores. Debido al deterioro que sobre la disponibilidad de los recursos han ejercido las actividades antropogénicas, es necesario orientar el tratamiento de las aguas residuales hacia tecnologías que ofrezcan el mayor grado de sustentabilidad, planteando innovaciones en el tratamiento. El presente proyecto de tesis doctoral versa sobre el estudio de la influencia de la relación C/N en la desnitrificación y metanogénesis de aguas residuales urbanas en un reactor anaeróbico de lecho fluidizado inverso (RLFI). Previamente a la realización de las pruebas experimentales de variación de la relación C/N, se llevó a cabo la etapa de arranque del RLFI la cual se inició en modo batch, favoreciendo la formación y adhesión de biopelícula al medio de soporte utilizado (Extendosphere). Después, sobrevino la operación en modo continuo desde una carga volumétrica aplicada (CVA) de 0.5 g DQOs/L⋅d hasta alcanzar 4 g DQOs/L⋅d, carga volumétrica a la cual se logró la plena estabilización del reactor, siendo la alta variabilidad de la concentración de DQOs en el agua residual urbana de alimentación, la principal problemática que ocasionó retrasos en la estabilidad del reactor. A una CVA de 4 g DQOs/L⋅d en estado estacionario, el valor mínimo de eficiencia de remoción de DQOs fue del 32.36% y el máximo de 66.99%. En estas condiciones el porcentaje de metano presente en el biogás producido tuvo un valor medio de 85.57 ± 2.93%, siendo un valor alto comparado con otros porcentajes de metano encontrados en la digestión anaerobia de aguas residuales urbanas. El YCH4 tuvo un valor medio de 0.316 ± 0.110 LCH4/g DQOrem⋅día. Los porcentajes de metanización variaron en el rango de 20.50 a 100%, registrándose un valor medio de 73.42 ± 25.63%. La considerable variabilidad en el porcentaje de metanización se debió principalmente a que se presentaron eventos de lavado de soporte colonizado, lo cual propició que las actividades metabólicas fueran orientadas hacia formación de biopelícula (anabolismo) en vez de estar dirigidas hacia producción de metano (catabolismo). En relación a los ensayos con variación de la relación C/N, se manejaron relaciones DQOs/N-NO3 en el rango de 1.65 a 21.1 g DQOs/g N-NO3. La tasa de remoción anaerobia de DQOs se incrementó con la concentración de sustrato en una relación casi lineal, ajustándose a una cinética de primer orden, lo que regularmente se presenta a concentraciones bajas de sustrato. La eficiencia del proceso de desnitrificación fue por lo regular alta, incrementándose ligeramente con la concentración de DQOs en el influente, con valores en el rango de 73.8 a 99.1%. Por otra parte, la tasa de remoción por metanogénesis se incrementó con la concentración relativa de sustrato (es decir, a mayores relaciones DQOs/N-NO3), siendo más sensitiva la metanogénesis a la concentración relativa de sustrato que la desnitrificación. Conforme aumentó la relación DQOs/N-NO3, la desnitrificación, de ser la ruta metabólica principal de utilización de la materia orgánica (comparada con la metanización), empezó a combinarse con la metanización. De manera evidente, a las relaciones DQOs/N-NO3 probadas, se manifestaron más las actividades desnitrificantes, quedando reflejadas por el alto porcentaje de utilización de la DQOs removida hacia la desnitrificación. La relación experimental DQOs/N-NO3 a la cual se pudiera haber cumplido con el requerimiento de materia orgánica (en términos de DQOs) para la desnitrificación de nitratos en las aguas residuales urbanas tratadas resultó aproximadamente ser igual a 7.1 g DQOs/g N-NO3. A una CVA de 4 g DQOs/L⋅d, se obtuvo un diámetro promedio máximo de soporte colonizado igual a 266.106 ± 69.279 μm aunque, hay que indicarlo, se presentaron fluctuaciones, las cuales se reflejaron también en el espesor de la biopelícula, el cual tuvo un valor máximo de 50.099 μm y un valor promedio de 37.294 ± 11.199 μm. Estas fluctuaciones pudieron deberse a la existencia de corrientes preferenciales dentro del reactor, las cuales no permitieron un acceso equitativo del sustrato a todo el lecho. Nitrification-denitrification is the traditional biological process for nitrogen removal from wastewaters (Ruiz G. et al., 2006a), being fundamental since it contributes to control the eutrophication of the receiving waters. Due to the deterioration that on the availability of the aquatic resources the anthropogenic activities have exerted, it is necessary to orient the treatment of wastewaters towards technologies that offer the greater degree of sustainability, raising innovations in the treatment. This work studied the influence of C/N ratio on denitrification and methanogenesis of urban wastewaters in an inverse fluidized bed reactor (IFBR). Previously to the accomplishment of the experimental tests with variation of C/N ratio, the start up of the IFBR was carried out in batch way, encouraging the formation and adhesion of biofilm to Extendosphere, which it was used as support. The operation in continuous way carried out from an organic loading rate (OLR) of 0.5 g CODs/L ∙ d to 4 g CODs/L ∙ d, when the steady-state was reached. The high variability of the CODs of the urban wastewaters caused delays in the stability of the reactor. Once stationary state was reached, the removal efficiency of CODs ranged from 32.36 to 66.99% to 4 g CODs/L ∙ d. In these conditions the percentage of methane in produced biogas had an average value of 85.57 ± 2.93%, being a high value compared with other studies treating anaerobically urban wastewaters. The YCH4 had an average value of 0.316 ± 0.110 LCH4/g CODrem ∙ d. The percentage of methanisation ranged from 20.50 to 100%, with an average value of 73.42 ± 25.63%. The considerable variability in the methanisation percentage occurred mainly due events of wash-out of colonized support, which caused that the metabolic activities were oriented towards formation of biofilm (anabolism) instead of methane production (catabolism). Concerning the tests with variation of C/N ratio, CODs/NO3-N ratios from 1.65 to 21.1 g CODs/g NO3-N were proved. The CODs anaerobic removal rate increased with the substrate concentration in an almost linear relation, adjusting to a kinetic of first order, which regularly appears to low concentrations of substrate. Efficiency of the denitrification process was regularly high, and it increased slightly with the CODs concentration in the influent, ranging from 73.8 to 99.1%. On the other hand, the CODs removal rate by methanogenesis increased with the substrate relative concentration (e.g., to greater CODs/NO3-N ratios), being more sensitive the methanogenesis to the substrate relative concentration that the denitrification. When the CODs/NO3-N ratio increased, the denitrification, of being the main metabolic route of use of the organic matter (compared with the methanogenesis), began to be combined with the methanogenesis. Definitively, to the proven CODs/NO3-N ratios the denitrification processes were more pronounced, being reflected by the high percentage of use of the removed CODs towards denitrification. The experimental CODs/NO3-N ratio to which it was possible to have been fulfilled the requirement of organic matter (in terms of CODs) for the denitrification of nitrates in urban wastewaters turned out to be approximately 7.1 g CODs/g NO3-N. It was obtained a maximum average diameter of colonized support of 266.106 ± 69.279 μm to 4 g CODs/L ∙ d, although it is necessary to indicate that appeared fluctuations in the thickness of biofilm, which had a maximum value of 50.099 μm and an average value of 37.294 ± 11.199 μm. These fluctuations could be due to the existence of preferential currents within the reactor, which did not allow an equitable access of the substrate to all the bed.
Resumo:
There exist different ways for defining a welfare function. Traditionally, welfare economic theory foundation is based on the Net Present Value (NPV) calculation where the time dependent preferences of considered agents are taken into account. However, the time preferences, remains a controversial subject. Currently, the traditional approach employs a unique discount rate for various agents. Nevertheless, this way of discounting appears inconsistent with sustainable development. New research work suggests that the discount rate may not be a homogeneous value. The discount rates may change following the individual’s preferences. A significant body of evidence suggests that people do not behave following a constant discount rate. In fact, UK Government has quickly recognized the power of the arguments for time-varying rates, as it has done in its official guidance to Ministries on the appraisal of investments and policies. Other authors deal with not just time preference but with uncertainty about future income (precautionary saving). In a situation in which economic growth rates are similar across time periods, the rationale for declining social optimal discount rates is driven by the preferences of the individuals in the economy, rather than expectations of growth. However, these approaches have been mainly focused on long-term policies where intergenerational risks may appear. The traditional cost-benefit analysis (CBA) uses a unique discount rate derived from market interest rates or investment rates of return for discounting the costs and benefits of all social agents included in the CBA. However, recent literature showed that a more adequate measure of social benefit is possible by using different discount rates including inter-temporal preferences rate of users, private investment discount rate and intertemporal preferences rate of government. Actually, the costs of opportunity may differ amongst individuals, firms, governments, or society in general, as do the returns on savings. In general, the firms or operators require an investment rate linked to the current return on savings, while the discount rate of consumers-users depends on their time preferences with respect of the current and the future consumption, as well as society can take into account the intergenerational well-being, adopting a lower discount rate for today’s generation. Time discount rate of social actors (users, operators, government and society) places a lower value in a future gain, but the uncertainty about future income strongly determines the individual preferences. These time and uncertainty depends on preferences and should be integrated into a transport policy formulation that may have significant social impacts. The discount rate of a user cannot be the same than the operator’s discount rate. The preferences of both are different. In addition, another school of thought suggests that people, such as a social group, may have different attitudes towards future costs and benefits. Particularly, the users have different discount rates related to their income. Some research work tried to modify user discount rates using a compensating weight which represents the inverse of household income level. The inter-temporal preferences are a proxy of the willingness to pay during the time. Its consideration is important in order to make acceptable or not a policy or investment
Resumo:
In pressure irrigation-water distribution networks, applied water volume is usually controlled opening a valve during a calculated time interval, and assuming constant flow rate. In general, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of pressure conditions.
Resumo:
The generation of identical droplets of controllable size in the micrometer range is a problem of much interest owing to the numerous technological applications of such droplets. This work reports an investigation of the regime of periodic emission of droplets from an electrified oscillating meniscus of a liquid of low viscosity and high electrical conductivity attached to the end of a capillary tube, which may be used to produce droplets more than ten times smaller than the diameter of the tube. To attain this periodic microdripping regime, termed axial spray mode II by Juraschek and Röllgen [R. Juraschek and F. W. Röllgen, Int. J. Mass Spectrom. 177, 1 (1998)], liquid is continuously supplied through the tube at a given constant flow rate, while a dc voltage is applied between the tube and a nearby counter electrode. The resulting electric field induces a stress at the surface of the liquid that stretches the meniscus until, in certain ranges of voltage and flow rate, it develops a ligament that eventually detaches, forming a single droplet, in a process that repeats itself periodically. While it is being stretched, the ligament develops a conical tip that emits ultrafine droplets, but the total mass emitted is practically contained in the main droplet. In the parametrical domain studied, we find that the process depends on two main dimensionless parameters, the flow rate nondimensionalized with the diameter of the tube and the capillary time, q, and the electric Bond number BE, which is a nondimensional measure of the square of the applied voltage. The meniscus oscillation frequency made nondimensional with the capillary time, f, is of order unity for very small flow rates and tends to decrease as the inverse of the square root of q for larger values of this parameter. The product of the meniscus mean volume times the oscillation frequency is nearly constant. The characteristic length and width of the liquid ligament immediately before its detachment approximately scale as powers of the flow rate and depend only weakly on the applied voltage. The diameter of the main droplets nondimensionalized with the diameter of the tube satisfies dd≈(6/π)1/3(q/f)1/3, from mass conservation, while the electric charge of these droplets is about 1/4 of the Rayleigh charge. At the minimum flow rate compatible with the periodic regimen, the dimensionless diameter of the droplets is smaller than one-tenth, which presents a way to use electrohydrodynamic atomization to generate droplets of highly conducting liquids in the micron-size range, in marked contrast with the cone-jet electrospray whose typical droplet size is in the nanometric regime for these liquids. In contrast with other microdripping regimes where the mass is emitted upon the periodic formation of a narrow capillary jet, the present regime gives one single droplet per oscillation, except for the almost massless fine aerosol emitted in the form of an electrospray.
Resumo:
The use of fly ash (FA) as an admixture to concrete is broadly extended for two main reasons: the reduction of costs that supposes the substitution of cement and the micro structural changes motivated by the mineral admixture. Regarding this second point, there is a consensus that considers that the ash generates a more compact concrete and a reduction in the size of the pore. However, the measure in which this contributes to the pozzolanic activity or as filler is not well defined. There is also no justification to the influence of the physical parameters, fineness of the grain and free water, in its behavior. This work studies the use of FA as a partial substitute of the cement in concretes of different workability (dry and wet) and the influence in the reactivity of the ash. The concrete of dry consistency which serves as reference uses a cement dose of 250 Kg/m 3 and the concrete of fluid consistency utilized a dose of cement of 350 Kg/m 3 . Two trademark of Portland Cement Type 1 were used. The first reached the resistant class for its fineness of grain and the second one for its composition. Moreover, three doses of FA have been used, and the water/binder ratio was constant in all the mixtures. We have studied the mechanical properties and the micro-structure of the concretes by means of compressive strength tests, mercury intrusion porosimetry (MIP) and thermal analysis (TA). The results of compressive strength tests allow us to observe that concrete mixtures with cements of the same classification and similar dosage of binder do not present the same mechanical behavior. These results show that the effective water/binder ratio has a major role in the development of the mechanical properties of concrete. The study of different dosages using TA, thermo-gravimetry and differential thermal analysis, revealed that the portlandite content is not restrictive in any of the dosages studied. Again, this proves that the rheology of the material influences the reaction rate and content of hydrated cement products. We conclude that the available free water is determinant in the efficiency of pozzolanic reaction. It is so that in accordance to the availability of free water, the ashes can react as an active admixture or simply change the porous distribution. The MIP shows concretes that do not exhibit significant changes in their mechanical behavior, but have suffered significant variation in their porous structure
Resumo:
El hormigón es uno de los materiales de construcción más empleados en la actualidad debido a sus buenas prestaciones mecánicas, moldeabilidad y economía de obtención, entre otras ventajas. Es bien sabido que tiene una buena resistencia a compresión y una baja resistencia a tracción, por lo que se arma con barras de acero para formar el hormigón armado, material que se ha convertido por méritos propios en la solución constructiva más importante de nuestra época. A pesar de ser un material profusamente utilizado, hay aspectos del comportamiento del hormigón que todavía no son completamente conocidos, como es el caso de su respuesta ante los efectos de una explosión. Este es un campo de especial relevancia, debido a que los eventos, tanto intencionados como accidentales, en los que una estructura se ve sometida a una explosión son, por desgracia, relativamente frecuentes. La solicitación de una estructura ante una explosión se produce por el impacto sobre la misma de la onda de presión generada en la detonación. La aplicación de esta carga sobre la estructura es muy rápida y de muy corta duración. Este tipo de acciones se denominan cargas impulsivas, y pueden ser hasta cuatro órdenes de magnitud más rápidas que las cargas dinámicas impuestas por un terremoto. En consecuencia, no es de extrañar que sus efectos sobre las estructuras y sus materiales sean muy distintos que las que producen las cargas habitualmente consideradas en ingeniería. En la presente tesis doctoral se profundiza en el conocimiento del comportamiento material del hormigón sometido a explosiones. Para ello, es crucial contar con resultados experimentales de estructuras de hormigón sometidas a explosiones. Este tipo de resultados es difícil de encontrar en la literatura científica, ya que estos ensayos han sido tradicionalmente llevados a cabo en el ámbito militar y los resultados obtenidos no son de dominio público. Por otra parte, en las campañas experimentales con explosiones llevadas a cabo por instituciones civiles el elevado coste de acceso a explosivos y a campos de prueba adecuados no permite la realización de ensayos con un elevado número de muestras. Por este motivo, la dispersión experimental no es habitualmente controlada. Sin embargo, en elementos de hormigón armado sometidos a explosiones, la dispersión experimental es muy acusada, en primer lugar, por la propia heterogeneidad del hormigón, y en segundo, por la dificultad inherente a la realización de ensayos con explosiones, por motivos tales como dificultades en las condiciones de contorno, variabilidad del explosivo, o incluso cambios en las condiciones atmosféricas. Para paliar estos inconvenientes, en esta tesis doctoral se ha diseñado un novedoso dispositivo que permite ensayar hasta cuatro losas de hormigón bajo la misma detonación, lo que además de proporcionar un número de muestras estadísticamente representativo, supone un importante ahorro de costes. Con este dispositivo se han ensayado 28 losas de hormigón, tanto armadas como en masa, de dos dosificaciones distintas. Pero además de contar con datos experimentales, también es importante disponer de herramientas de cálculo para el análisis y diseño de estructuras sometidas a explosiones. Aunque existen diversos métodos analíticos, hoy por hoy las técnicas de simulación numérica suponen la alternativa más avanzada y versátil para el cálculo de elementos estructurales sometidos a cargas impulsivas. Sin embargo, para obtener resultados fiables es crucial contar con modelos constitutivos de material que tengan en cuenta los parámetros que gobiernan el comportamiento para el caso de carga en estudio. En este sentido, cabe destacar que la mayoría de los modelos constitutivos desarrollados para el hormigón a altas velocidades de deformación proceden del ámbito balístico, donde dominan las grandes tensiones de compresión en el entorno local de la zona afectada por el impacto. En el caso de los elementos de hormigón sometidos a explosiones, las tensiones de compresión son mucho más moderadas, siendo las tensiones de tracción generalmente las causantes de la rotura del material. En esta tesis doctoral se analiza la validez de algunos de los modelos disponibles, confirmando que los parámetros que gobiernan el fallo de las losas de hormigón armado ante explosiones son la resistencia a tracción y su ablandamiento tras rotura. En base a los resultados anteriores se ha desarrollado un modelo constitutivo para el hormigón ante altas velocidades de deformación, que sólo tiene en cuenta la rotura por tracción. Este modelo parte del de fisura cohesiva embebida con discontinuidad fuerte, desarrollado por Planas y Sancho, que ha demostrado su capacidad en la predicción de la rotura a tracción de elementos de hormigón en masa. El modelo ha sido modificado para su implementación en el programa comercial de integración explícita LS-DYNA, utilizando elementos finitos hexaédricos e incorporando la dependencia de la velocidad de deformación para permitir su utilización en el ámbito dinámico. El modelo es estrictamente local y no requiere de remallado ni conocer previamente la trayectoria de la fisura. Este modelo constitutivo ha sido utilizado para simular dos campañas experimentales, probando la hipótesis de que el fallo de elementos de hormigón ante explosiones está gobernado por el comportamiento a tracción, siendo de especial relevancia el ablandamiento del hormigón. Concrete is nowadays one of the most widely used building materials because of its good mechanical properties, moldability and production economy, among other advantages. As it is known, it has high compressive and low tensile strengths and for this reason it is reinforced with steel bars to form reinforced concrete, a material that has become the most important constructive solution of our time. Despite being such a widely used material, there are some aspects of concrete performance that are not yet fully understood, as it is the case of its response to the effects of an explosion. This is a topic of particular relevance because the events, both intentional and accidental, in which a structure is subjected to an explosion are, unfortunately, relatively common. The loading of a structure due to an explosive event occurs due to the impact of the pressure shock wave generated in the detonation. The application of this load on the structure is very fast and of very short duration. Such actions are called impulsive loads, and can be up to four orders of magnitude faster than the dynamic loads imposed by an earthquake. Consequently, it is not surprising that their effects on structures and materials are very different than those that cause the loads usually considered in engineering. This thesis broadens the knowledge about the material behavior of concrete subjected to explosions. To that end, it is crucial to have experimental results of concrete structures subjected to explosions. These types of results are difficult to find in the scientific literature, as these tests have traditionally been carried out by armies of different countries and the results obtained are classified. Moreover, in experimental campaigns with explosives conducted by civil institutions the high cost of accessing explosives and the lack of proper test fields does not allow for the testing of a large number of samples. For this reason, the experimental scatter is usually not controlled. However, in reinforced concrete elements subjected to explosions the experimental dispersion is very pronounced. First, due to the heterogeneity of concrete, and secondly, because of the difficulty inherent to testing with explosions, for reasons such as difficulties in the boundary conditions, variability of the explosive, or even atmospheric changes. To overcome these drawbacks, in this thesis we have designed a novel device that allows for testing up to four concrete slabs under the same detonation, which apart from providing a statistically representative number of samples, represents a significant saving in costs. A number of 28 slabs were tested using this device. The slabs were both reinforced and plain concrete, and two different concrete mixes were used. Besides having experimental data, it is also important to have computational tools for the analysis and design of structures subjected to explosions. Despite the existence of several analytical methods, numerical simulation techniques nowadays represent the most advanced and versatile alternative for the assessment of structural elements subjected to impulsive loading. However, to obtain reliable results it is crucial to have material constitutive models that take into account the parameters that govern the behavior for the load case under study. In this regard it is noteworthy that most of the developed constitutive models for concrete at high strain rates arise from the ballistic field, dominated by large compressive stresses in the local environment of the area affected by the impact. In the case of concrete elements subjected to an explosion, the compressive stresses are much more moderate, while tensile stresses usually cause material failure. This thesis discusses the validity of some of the available models, confirming that the parameters governing the failure of reinforced concrete slabs subjected to blast are the tensile strength and softening behaviour after failure. Based on these results we have developed a constitutive model for concrete at high strain rates, which only takes into account the ultimate tensile strength. This model is based on the embedded Cohesive Crack Model with Strong Discontinuity Approach developed by Planas and Sancho, which has proved its ability in predicting the tensile fracture of plain concrete elements. The model has been modified for its implementation in the commercial explicit integration program LS-DYNA, using hexahedral finite elements and incorporating the dependence of the strain rate, to allow for its use in dynamic domain. The model is strictly local and does not require remeshing nor prior knowledge of the crack path. This constitutive model has been used to simulate two experimental campaigns, confirming the hypothesis that the failure of concrete elements subjected to explosions is governed by their tensile response, being of particular relevance the softening behavior of concrete.
Resumo:
The growth of the Internet has increased the need for scalable congestion control mechanisms in high speed networks. In this context, we propose a rate-based explicit congestion control mechanism with which the sources are provided with the rate at which they can transmit. These rates are computed with a distributed max-min fair algorithm, SLBN. The novelty of SLBN is that it combines two interesting features not simultaneously present in existing proposals: scalability and fast convergence to the max-min fair rates, even under high session churn. SLBN is scalable because routers only maintain a constant amount of state information (only three integer variables per link) and only incur a constant amount of computation per protocol packet, independently of the number of sessions that cross the router. Additionally, SLBN does not require processing any data packet, and it converges independently of sessions' RTT. Finally, by design, the protocol is conservative when assigning rates, even in the presence of high churn, which helps preventing link overshoots in transient periods. We claim that, with all these features, our mechanism is a good candidate to be used in real deployments.