6 resultados para Composition of the continental crust
em Universidad Politécnica de Madrid
Resumo:
The pathogenicity of seven strains of Fusarium equiseti isolated from seabed soil was evaluated on different host plants showing pre and post emergence damage. Radial growth of 27 strains was measured on culture media previously adjusted to different osmotic potentials with either KCl or NaCl (-1.50 to - 144.54 bars) at 15º, 25º and 35º C. Significant differences and interactive effects were observed in the response of mycelia to osmotic potential and temperature.
Resumo:
The use of vegetal systems in facades affects the reduction of the buildings' energy demand, the attenuation of the urban heat island (UHI) and the filtration of pollutants present in the air. Even so, up to now the knowledge about the effect of this type of systems on the thermal performance of insulated facades is limited. This article presents the results of an experimental study carried out in a vegetal facade located in a continental Mediterranean climate zone. The objective is to study the effect of a vegetal finishing, formed by plants and substrate, on the thermal-energy performance of an insulated facade under summer conditions. To this effect, the thermal data obtained from two full-scale experimental mock-ups of the same dimensions and composition of the enclosure and only different in the south facade's enclosure where one incorporates a vegetation layer are compared and analysed. The results show that, in spite of the high thermal resistance of the enclosure, the effect of the vegetation is very positive, particularly in the warmer hours of the day. Therefore, vegetal facades can be used as a passive cooling strategy, reducing the consumption of energy for refrigeration and improving the comfort conditions of the users. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Links between phenology, yield and composition of the essential oil of common sage, Salvia officinalis L., grown in Guadalajara (Central Spain) were determined in the different phases of the biological cycle during one year. Data showed an average yield about 1.0%. The analysis of the oil components was carried out by GC-FID and GC/MS. The main oil constituent was alpha thujone (40.1 - 46.5%). Other identified compounds are beta pinene (2.6 - 4.5%), cineole (3.5 - 8.7%), beta thujone (4.1 - 5.6%), camphor (4.1 - 8.0%), borneol (1.3 - 3.7%), alpha humulene (3.8 - 7.3%), viridiflorol (3.4-12.6%) and manool (0.1-4.5%). The highest yield of oil was obtained in the period of full flowering and the highest concentration of alpha thujone in the period of initial flowering.
Resumo:
The origin of the modified optical properties of InAs/GaAs quantum dots (QD) capped with a thin GaAs1−xSbx layer is analyzed in terms of the band structure. To do so, the size, shape, and composition of the QDs and capping layer are determined through cross-sectional scanning tunnelling microscopy and used as input parameters in an 8 × 8 k·p model. As the Sb content is increased, there are two competing effects determining carrier confinement and the oscillator strength: the increased QD height and reduced strain on one side and the reduced QD-capping layer valence band offset on the other. Nevertheless, the observed evolution of the photoluminescence (PL) intensity with Sb cannot be explained in terms of the oscillator strength between ground states, which decreases dramatically for Sb > 16%, where the band alignment becomes type II with the hole wavefunction localized outside the QD in the capping layer. Contrary to this behaviour, the PL intensity in the type II QDs is similar (at 15 K) or even larger (at room temperature) than in the type I Sb-free reference QDs. This indicates that the PL efficiency is dominated by carrier dynamics, which is altered by the presence of the GaAsSb capping layer. In particular, the presence of Sb leads to an enhanced PL thermal stability. From the comparison between the activation energies for thermal quenching of the PL and the modelled band structure, the main carrier escape mechanisms are suggested. In standard GaAs-capped QDs, escape of both electrons and holes to the GaAs barrier is the main PL quenching mechanism. For small-moderate Sb (<16%) for which the type I band alignment is kept, electrons escape to the GaAs barrier and holes escape to the GaAsSb capping layer, where redistribution and retraping processes can take place. For Sb contents above 16% (type-II region), holes remain in the GaAsSb layer and the escape of electrons from the QD to the GaAs barrier is most likely the dominant PL quenching mechanism. This means that electrons and holes behave dynamically as uncorrelated pairs in both the type-I and type-II structures.
Resumo:
This research in Cordoba's mosque tower main objective was to analyze and characterize the foundations and the underlying soil, calculating the stability of the monument as well as the settlement and deformations performed, using traditional calculation methods and also by finite elements, and to determine differences between both, as well as the stability factor of the Minaret Tower. The works done to study the soil, were drill bores and dynamic penetration tests, classification of samples by size, Atterberg limits, physical and chemical analysis, showing the typical geotechnical composition of the Guadalquivir valley: an alluvial material composed by sand, gravels and silt clays. To study the foundations, inclined bore samples were extracted with 10-65º, showing calcarenite stone ashlars and lime concrete alternating with stone and brick masonry.
Resumo:
For the energy valorization of alperujo, residue of the olive oil two phases extraction process, it is necessary to perform a drying process to reduce moisture content from over 60% to less than 10%. In order to reduce primary energy consumption and get an economic return, usually in this kind of drying facilities Gas Turbine CHP is used as a heat source. There have been recently in Spain some fires in this kind of GT-CHP facilities, which have caused high material losses. In some of these fires it has been suggested that the fire was caused by the output of incandescent alperujo in the flue gasesof the drying system. Therefore, the aim of this study is to determine experimentally and analytically under which operational conditions a process of alperujo self-ignition in the drying process can begin, and determine the actual fire hazard in this type of TG-CHP system. For analytical study, the temperature and initial composition of the combustion gases of the Gas Turbine at the entrance of the drying process was calculated and the gas equilibrium conditions reached in contact with the biomass were calculated and, therefore, the temperature of the biomass during the drying process. Moreover, the layer and dust ignition temperature of alperujo has been experimentally determined, according to EN 50281-2-1: 2000. With these results, the operating conditions of the drying process, in which there are real risk of auto-ignition of alperujo have been established.Para la valorización energética del alperujo, residuo del proceso de extracción en dos fases del aceite de oliva, es necesario realizar un proceso de secado para reducir su contenido de humedad de más del 60% al 10% m/m en b.h. Con el fin de reducir el consumo de energía primaria y obtener una rentabilidad económica, normalmente en este tipo de instalaciones de secado se usa la cogeneración con turbina de gas (TG) como fuente de calor. En España en los últimos años han ocurrido algunos casos de incendio en este tipo de instalaciones de cogeneración, que han supuesto pérdidas materiales muy elevadas. Por esta razón, el objetivo de este trabajo es determinar analítica y experimentalmente las condiciones operativas del secadero bajo las cuales podría comenzar un proceso de autoinflamación del alperujo y determinar el riesgo real de incendio en este tipo de instalaciones. Para el estudio analítico, se ha planteado y validado el modelo matemático que permite calcular la temperatura y la composición de los gases de combustión a la entrada y a la salida del secadero, en función de las curvas características de la TG, de las condiciones atmosféricas, del caudal y del grado de humedad de la biomasa tratada. El modelo permite además calcular la temperatura de bulbo húmedo, que es la máxima temperatura que podría alcanzar la biomasa durante el proceso de secado y determinar la cantidad de biomasa que se puede secar completamente en función del caudal y de las condiciones de entrada de los gases de combustión. Con estos resultados y la temperatura mínima de autoinflamación del alperujo determinada experimentalmente siguiendo la norma EN 50281- 2-1:2000, se demuestra que en un proceso de secado de alperujo en condiciones normales de operación no existe riesgo de autoencendido que pueda dar origen a un incendio.