3 resultados para Central nervous system - Effect of drugs on

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of crystal misorientation, geometrical tilt, and contact misalignment on the compression of highly anisotropic single crystal micropillars was assessed by means of crystal plasticity finite element simulations. The investigation was focused in single crystals with the NaCl structure, like MgO or LiF, which present a marked plastic anisotropy as a result of the large difference in the critical resolved shear stress between the “soft” {110}〈110〉 and the “hard” {100}〈110〉 active slip systems. It was found that contact misalignment led to a large reduction in the initial stiffness of the micropillar in crystals oriented in the soft and hard direction. The crystallographic tilt did not modify, however, the initial crystal stiffness. From the viewpoint of the plastic response, none of the effects analyzed led to significant differences in the flow stress when the single crystals were oriented along the “soft” [100] direction. Large differences were found, however, if the single crystal was oriented in the “hard” [111] direction as a result of the activation of the soft slip system. Numerical simulations were in very good agreement with experimental literature data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to examine the effect of positioning on the correctness of decision making of top-class referees and assistant referees during international games. Match analyses were carried out during the Fe´de´ration Internationale de Football Association (FIFA) Confederations Cup 2009 and 380 foul play incidents and 165 offside situations were examined. The error percentage for the referees when indicating the incidents averaged 14%. The lowest error percentage occurred in the central area of the field, where the collaboration of the assistant referee is limited, and was achieved when indicating the incidents from a distance of 11–15 m, whereas this percentage peaked (23%) in the last 15-min match period. The error rate for the assistant referees was 13%. Distance of the assistant referee to the offside line did not have an impact on the quality of the offside decision. The risk of making incorrect decisions was reduced when the assistant referees viewed the offside situations from an angle between 46 and 608. Incorrect offside decisions occurred twice as often in the second as in the first half of the games. Perceptual-cognitive training sessions specific to the requirements of the game should be implemented in the weekly schedule of football officials to reduce the overall error rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A measurement investigation, at ADIF's test site at the O Eixo viaduct which is on the Spanish Santiago-Ourense high speed railway line, has been carried out during the last year. The main goal of the investigation is to study the effect of the cross-wind on railway overheads (catenaries) and the influence of the presence of windbreaks on the wind-induced motion of the railway overhead. A description of the O Eixo viaduct test site is presented in this paper, including the installed windbreaks, the sensor and power supply systems. Three catenary spans has been instrumented at the center point of the catenary span contact wire with one ultrasonic anemometer and two unidirectional accelerometers. Additionally, another ultrasonic anemometer placed in the central catenary span has been installed to provide reference wind data. Wind roses of wind speed and standard deviation of the accelerometers are presented. As expected, the four wind roses look very similar and the two dominant directions close to the perpendicular to the bridge longitudinal axes, north and south have been identified. The wind roses of the standard deviation of the acceleration shows that the acceleration of the catenary contact wire is related to the directions of the two dominant winds. The vertical standard deviation of the acceleration is higher than the horizontal one for the spans with windbreaks. It has also been observed that the presence of the windbreaks modifies the wind flow leading to a wind-induced motion of the catenary contact wire which shows a higher variability than the corresponding unprotected case. On the one hand, the baseline southerly wind configuration (south wind, windbreaks in the windward side and catenary in the leeward side) influence both the mean speed at the catenary and the turbulence intensity. On the other hand, the northerly wind configuration, windbreaks in the leeward side and catenary in the windward side, provide a reference to the response of the catenary for an unprotected railway overhead, and, as it is expected, the windbreak influence is much more reduced compared to the southerly wind configuration. Both the height of the windbreak and the eaves contribute to the increase in the turbulence intensity at the catenary contact wire height. It can be seen that the height of the windbreak plays a crucial role in the increase of turbulence intensity, much more intense than the presence of the windbreak eave.