13 resultados para CONDENSATION
em Universidad Politécnica de Madrid
Resumo:
Phase changing flows are being considered for thermal management in space platforms. The resulting flow patterns are very complicated and extremely sensitive to gravity action. Concerning fluid flow in ducts, the available evidence indicates that although the pressure loss does not depend too much on the fluid flow pattern,the heat transfer (and resulting phase change) does. A simple exercise to illustrate this point is presented in this paper. It deals with condensing flow in straight circular cross-sectional ducts. Two extreme configurations are considered here, one corresponds to a stratified flow and the other to an annular flow. Both types of flow patterns have been extensively considered in the past and from this point of view almost nothing is new in the paper, but past results look conflictive and this could be due to the limitations and computational intricacies of the models used. Thus the problem has been reformulated from the onset and the results are presented as the evolution of the vapor quality (vapor to total mass flow rate) along the duct, in typical cases. The results presented here indicate that within the validity of the present models and the assumed ranges of mass flow rate, duct diameter, thermal conditions and fluid characteristics,the length of the ducts required to achieve complete condensation under zero gravity are an order of magnitude larger than in horizontal tubes under normal terrestrial conditions.
Resumo:
La envolvente de la edificación es la responsable de equilibrar el intercambio energético entre el interior y el exterior, por lo tanto cualquier actuación encaminada a la reducción del consumo energético ha de establecer, como uno de sus objetivos prioritarios, la mejora del comportamiento de la misma. Las edificaciones anteriores a 1940 constituyen la mayor parte de las existentes en áreas rurales y centros urbanos. En ellas, la repercusión de la fachada sobre las transmitancias globales pone de manifiesto la necesidad de intervención. Sin embargo, su elevada inercia térmica y los importantes saltos térmicos característicos de gran parte de España plantean la importancia de que aquélla se efectúe por el exterior. A tal respecto, la falta de disponibilidad de espesor suficiente para implantar sistemas tipo SATE deriva en que, frecuentemente, la única solución viable sea la de aislar por el interior perdiendo con ello la capacidad de acumulación térmica del muro y con el asociado riesgo de condensaciones. La amplia tradición en el empleo de revestimientos, especialmente en base de cal, permiten que éstos sean utilizados no sólo como elemento estético o de protección de la obra de fábrica antigua sino también para la mejora del comportamiento térmico del soporte, si se aprovecha el mecanismo de transmisión térmica por radiación. Éste es el objetivo de la presente Tesis Doctoral en la que se estudia la modificación de las propiedades radiantes de los morteros de revestimiento para la mejora de la eficiencia energética de las construcciones históricas, principalmente las constituidas por muros monolíticos, aunque podría ser de aplicación a otro tipo de construcciones compuestas por diversas capas. Como punto de partida, se estudió y revisó la documentación disponible sobre las investigaciones de las tres áreas científico-tecnológicas que convergen en la Tesis Doctoral: rehabilitación, material y comportamiento térmico, a partir de lo cual se comprobó la inexistencia de estudios similares al objeto de la presente Tesis Doctoral. Complementariamente, se analizaron los revestimientos en lo concerniente a los materiales que los constituyen, la composición de las mezclas y características de cada una de las capas así como al enfoque que, desde el punto de vista térmico, se estimaba más adecuado para la obtención de los objetivos propuestos. Basándonos en dichos análisis, se preseleccionaron ochenta materiales que fueron ensayados en términos de reflectancia y emisividad para elegir cuatro con los que se continuó la investigación. Éstos, junto con la cal elegida para la investigación y el árido marmóreo característico de la última capa de revestimiento, fueron caracterizados térmicamente, de forma pormenorizada, así como química y físicamente. Los fundamentos teóricos y los estudios preliminares desarrollados con distintos materiales, en estado fresco y endurecido, fueron empleados en la dosificación de componentes de las mezclas, en dos proporciones distintas, para el estudio del efecto del agregado. Éstas se ensayaron en estado fresco, para comprobar su adecuación de puesta en obra y prever su VI adherencia al soporte, así como en estado endurecido a 28 y 90 días de curado, para conocer las propiedades que permitieran prever su compatibilidad con aquél y estimar el alcance de la reducción de transferencias térmicas lograda. Además, se estudiaron las características generales de las mezclas que sirvieron para establecer correlaciones entre distintas propiedades y entender los resultados mecánicos, físicos (comportamiento frente al agua) y energéticos. Del estudio conjunto de las distintas propiedades analizadas se propusieron dos mezclas, una blanca y otra coloreada, cuyas características permiten garantizar la compatibilidad con la obra de fábrica antigua, desde el punto de vista físico y mecánico, y preservar la autenticidad de los revestimientos, en cuanto a la técnica de aplicación tradicional en sistemas multicapa. El comportamiento térmico de las mismas, sobre una obra de fábrica de 40 cm de espesor, se estimó, en estado estacionario y pseudo-transitorio, demostrándose reducciones del flujo térmico entre 16-48%, en condiciones de verano, y entre el 6-11%, en invierno, en función de la coloración y de la rugosidad de la superficie, en comparación con el empleo de la mezcla tradicional. Por lo que, se constata la viabilidad de los materiales compuestos propuestos y su adecuación al objetivo de la investigación. VII ABSTRACT The envelope is responsible for balancing the energy exchange between the inside and outside in buildings. For this reason, any action aimed at reducing energy consumption must establish, as one of its key priorities, its improvement. In rural areas and urban centers, most of the constructions were built before 1940. In them, the impact of the façade on the global transmittance highlights the need for intervention. However, its high thermal inertia and fluctuation of temperatures in the majority of Spain bring up that it should be placed outside the insulation. In this regard, the lack of availability of enough thickness to implement systems such as ETICS results in that often the only viable solution is to isolate the interior, losing thereby the wall’s heat storage capacity with the associated risk of condensation. The tradition in the use of renders, especially lime-based, allows us to use them not only as an aesthetic element or to protect the ancient masonry, but also for improved thermal performance of the support by taking advantage of the heat transfer mechanism by radiation. This is the aim of this Doctoral Thesis in which the modification of the radiative properties of lime mortars for renders to improve the energy efficiency of historic buildings, mainly composed of monolithic walls, is studied, although it could be applied to other structures composed of several layers. As a starting point, the available literature in the three scientific-technological areas that converge at the Doctoral Thesis: rehabilitation, material and thermal behaviour, was reviewed, and confirmed the absence of researches similar to this Doctoral Thesis. Additionally, the renders were studied with regard to the materials that constitute them, the composition of the mixtures and the characteristics of each layer, as well as to the approach which, from a thermal point of view, was deemed the most suitable for achieving the objectives sets. Based on thre aforementioned analysis, eighty materials tested in terms of reflectance and emissivity were pre-selected, to choose four with which the research was continued. Common marble sand, used in the last layer of the renders, together with the appointed materials and hydrated lime were characterized thermally, in detail, as well as chemically and physically. The theoretical bases and preliminary studies with different materials, in fresh and hardened state, were used in the dosage of the composition of the mixtures. In order to study their effect they were used in two different proportions, that is, ten mixtures in total. These were tested in their fresh state to evaluate their setting-up suitability and foresee their adhesion to the support, as well as in their hardened state, at 28 and 90 days of curing, to establish the properties which enabled us to anticipate their compatibility with the old masonry walls and estimate the scope of the reduction of heat transfers achieved. In addition, the general characteristics of the mixtures used to establish correlations and to understand the mechanical, physical and energy results were studied. Two mixtures, one white and one colored, were proposed as the result of the different properties analysed, whose characteristics allow the guarantee of mechanical and physical compatibility VIII with the old masonry and preserve the authenticity of the renders. The thermal behavior of both, applied on a masonry wall 40 cm thick, was estimated at a steady and pseudo-transient state, with heat flow reductions between 16-48% during summertime and 6-11% during wintertime, depending on the color and surface roughness, compared to the use of the traditional mixture. So, the viability of the proposed composite materials and their fitness to the aim of the research are established.
Resumo:
Young trees transplanted from nursery into open field require a minimum amount of soil moisture to successfully root in their new location, especially in dry-climate areas. One possibility is to obtain the required water from air moisture. This can be achieved by reducing the temperature of a surface below the air dew point temperature, inducing water vapor condensation on the surface. The temperature of a surface can be reduced by applying the thermoelectric effect, with Peltier modules powered by electricity. Here, we present a system that generates electricity with a solar photovoltaic module, stores it in a battery, and finally, it uses the electricity at the moment in which air humidity and temperature are optima to maximize water condensation while minimizing energy consumption. Also, a method to reduce the evaporation of the condensed water is proposed. The objective of the system, rather than irrigating young plants in such a degree as to boost their growth, is to maintain them alive in the dryer periods.
Resumo:
El alcance del proyecto es describir las directrices técnicas, la definición de criterios, y la estrategia de suministro de energía (Electricidad. Calefacción y Agua Caliente Sanitaria (ACS)) a un barrio modelo situado en un entorno urbano. De inicio se estudia los diversos modelos energéticos atendiendo a la normativa y tecnología, que se pueden aplicar en un conjunto residencial, dando como resultado el modelo propuesto de abastecimiento energético, mediante calefacción de distrito, que incorporara el diseño de una planta de producción de energía termo-eléctrica o Central de Energías basada en la tecnología de condensación de baja temperatura para calefacción y A.C.S. incluyendo una cogeneración con pila de combustible. Al mismo tiempo se han calculado y diseñado una serie de chimeneas externas para dar cumplida necesidad técnica y legal al proyecto. Estos estudios nos sirven de punto de partida para analizar la amortización de la inversión y por tanto la rentabilidad y viabilidad del proyecto, comparándose con los costes económicos derivados de la generación por sistemas convencionales. Para finalizar se hace mención a las ventajas medioambientales y a los grados de seguridad en la planta de producción ABSTRACT The scope of this work is the description of an energy supply project ( Electricity, heat and hot water ) to a housing development in a urban neibourhood , including technical criteria in their different options. Initially, several solutions are studied based on available technologies and legal restrictions. The final proposal is based on the district hearing model including electricity production in cogeneration via fuel cell technology as well as heating and hot water produced by low temperature condensation boilers It includes calculations and design criteria of the exhaust gases system and chimeneys in compliance with legal requirement in urban areas. This work also includes an economical model including payback, IRR and VAN analysis and an economical comparaison with the standard solutions. Finally, environmental advantages of the preferred solution over other standards as well as safety issues are also presented.
Resumo:
Young trees transplanted from nursery into open field require a minimum amount of soil moisture to successfully root in their new location, especially in dry-climate areas. One possibility is to obtain the required water from air moisture. This can be achieved by reducing the temperature of a surface below the air dew point temperature, inducing water vapor condensation on the surface. The temperature of a surface can be reduced by applying the thermoelectric effect, with Peltier modules powered by electricity. Here, we present a system that generates electricity with a solar photovoltaic module, stores it in a battery, and finally, uses the electricity at the moment in which air humidity and temperature are optimal to maximize water condensation while minimizing energy consumption. Also, a method to reduce the evaporation of the condensed water is proposed. The objective of the system is to sustain young plants in drier periods, rather than exclusively irrigating young plants to boost their growth.
Resumo:
Solar thermal power plants are usually installed in locations with high yearly average solar radiation, often deserts. In such conditions, cooling water required for thermodynamic cycles is rarely available. Moreover, when solar radiation is high, ambient temperature is very high as well; this leads to excessive condensation temperature, especially when air-condensers are used, and decreases the plant efficiency. However, temperature variation in deserts is often very high, which drives to relatively low temperatures during the night. This fact can be exploited with the use of a closed cooling system, so that the coolant (water) is chilled during the night and store. Chilled water is then used during peak temperature hours to cool the condenser (dry cooling), thus enhancing power output and efficiency. The present work analyzes the performance improvement achieved by night thermal cool storage, compared to its equivalent air cooled power plant. Dry cooling is proved to be energy-effective for moderately high day–night temperature differences (20 °C), often found in desert locations. The storage volume requirement for different power plant efficiencies has also been studied, resulting on an asymptotic tendency.
Resumo:
This paper presents a numerical implementation of the cohesive crack model for the anal-ysis of quasibrittle materials based on the strong discontinuity approach in the framework of the finite element method. A simple central force model is used for the stress versus crack opening curve. The additional degrees of freedom defining the crack opening are determined at the crack level, thus avoiding the need for performing a static condensation at the element level. The need for a tracking algorithm is avoided by using a consistent pro-cedure for the selection of the separated nodes. Such a model is then implemented into a commercial program by means of a user subroutine, consequently being contrasted with the experimental results. The model takes into account the anisotropy of the material. Numerical simulations of well-known experiments are presented to show the ability of the proposed model to simulate the fracture of quasibrittle materials such as mortar, concrete and masonry.
Resumo:
El aumento progresivo de la temperatura media anual y el déficit hídrico están provocando importantes cambios en la composición y la maduración de la uva, que repercuten directamente sobre el proceso fermentativo y, por ende, sobre la calidad del vino elaborado. En este trabajo se evalúan diferentes estrategias para la reducción del grado alcohólico, la mejora del color del vino y su estabilidad, y el incremento y la persistencia aromática. Mediante el empleo de levaduras con ineficiencia glicolítica se lograron reducciones medias en el grado alcohólico de entre 0.3 y 1.7 % v/v, mientras que con las fermentaciones secuenciales la máxima reducción lograda fue de 3.3 y 3.4 % v/v al combinar las cepas 938 (Schizosaccharomyces pombe) y 7013 (Torulaspora delbrueckii) con la 7VA (Saccharomyces cerevisiae). Al aplicar un tratamiento térmico sobre el inóculo, la TP2A(16) mostró una reducción media significativa en el grado alcohólico de 1 % v/v. El principal inconveniente en todas las técnicas empleadas para reducir el grado alcohólico fue la falta de repetibilidad en los resultados obtenidos. Por otra parte, la aplicación de altas presiones sobre uva despalillada resultó efectiva como tratamiento de pasteurización y como potenciador de la extracción de polifenoles, logrando un incremento en el contenido medio de antocianos totales del 12.4-18.5 %. La adición de flavonoides al mosto estimuló la formación de pigmentos estables como resultado de su condensación con antocianos mediada por acetaldehído. Con el empleo de Torulaspora delbrueckii en fermentación secuencial fue posible incrementar la producción de diacetilo y acetato de 2-feniletilo, además de la síntesis de un nuevo compuesto, el 3-etoxi-1-propanol. Sin embargo, su aportación sobre el color fue nula, así que debería combinarse con una cepa de Saccharomyces cerevisiae con buena formación de pigmentos piranoantociánicos. El empleo de Schizosaccharomyces pombe (938, V1) y Torulaspora delbrueckii (1880) en fermentaciones secuenciales y mixtas con Saccharomyces cerevisiae permitió mejorar el perfil sensorial del vino tinto mediante la mayor síntesis de polioles y la potenciación de aromas frutales, florales y herbáceos, e incrementar la estabilidad de la materia colorante al favorecer la formación de vitisinas y piranoantocianos vinilfenólicos. La crianza sobre lías en barrica a partir de levaduras seleccionadas, puede mejorar la complejidad y persistencia aromática del vino tinto, aunque sin grandes cambios en el color. ABSTRACT The progressive increase in annual average temperature, along with water deficit, is causing significant changes in grape composition and in its maturation, which directly affects the fermentative process and hence alters wine quality. In this work, different strategies for reducing the alcoholic strength, improve wine color and its stability, and increase aromatic complexity and its persistence, are evaluated. By using yeasts with glycolytic inefficiency, it was possible to achieve mean reductions between 0.3 and 1.7 % v/v in the alcoholic strength, while sequential fermentations allowed a maximum reduction of 3.3 and 3.4 % v/v by combining strains 938 (Schizosaccharomyces pombe) and 7013 (Torulaspora delbrueckii) with 7VA (Saccharomyces cerevisiae). When applying a heat shock treatment on the inoculum, only TP2A(16) strain showed a significant mean reduction of 1 % v/v in the alcohol content, compared with the control. The main drawback in all the techniques used to reduce the alcohol content was the lack of repeatability in the results. Moreover, the application of high pressures on destemmed grapes was effective as pasteurization treatment and also as enhancer of polyphenol extraction, achieving an increase of 12.4-18.5% in the average content of total anthocyanins. As expected, addition of flavonoids to the must, stimulated the formation of stable pigments, mainly as a result of condensation reactions between anthocyanins and flavanols mediated by acetaldehyde. With the use of Torulaspora delbrueckii strains in sequential fermentation with Saccharomyces cerevisiae, it was possible to increase the production of diacetyl and 2-phenylethyl acetate, besides the synthesis of a new compound: 3-ethoxy-1-propanol. The use of Schizosaccharomyces pombe (938, V1) and Torulaspora delbrueckii (1880) strains in sequential and mixed fermentations with Saccharomyces cerevisiae improved the sensory profile of red wine by increasing polyols synthesis and enhancing fruity, floral and herbaceous aromas, and it also increased the stability of the coloring matter by favouring vitisins and vinylphenolic pyranoanthocyanins formation. Ageing on lees in barrels from selected yeasts can improve the complexity and aromatic persistence of red wine, without major changes in the color.
Resumo:
This article reviews all the experimental tests carried out to analyze the performance of a FluidReflex photovoltaic concentrator. This novel concentrator concept consists of a single reflective stage immersed in an optical fluid. The presence of the fluid entails significant advantages. It not only allows a high system optical efficiency and increases the attainable concentration but also enhances the heat dissipation from the cell. In addition, the electrical insulation is improved, and the problem of water vapor condensation inside the module is avoided. A complete characterization is addressed in this paper. Among the experimental results, a measured optical efficiency of 83.5% for a concentration of 1035× stands out
Resumo:
Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.
Resumo:
El objetivo principal de este trabajo es profundizar en el conocimiento del fenómeno de la corrosión subpelicular inducida por contaminantes hidrosolubles en la intercara metal/pintura. La contaminación salina del substrato es una situación común en la práctica: la superficie metálica suele estar expuesta a atmósferas contaminadas antes de ser recubierta, limpieza previa del metal con abrasivos contaminados, etc. La eliminación total de estos contaminantes resulta muy difícil de conseguir incluso con las técnicas más sofisticadas de limpieza. Esta investigación se centra en la determinación del efecto de la naturaleza del contaminante y la naturaleza y espesor del recubrimiento en el proceso de corrosión subpelicular del acero. En la investigación se utilizaron dos barnices de naturaleza diferente: poliuretano y vinílico; y se aplicaron a tres espesores diferentes. Los contaminantes empleados en este trabajo fueron: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03, Ca(N03)2. Los ensayos se realizaron en una cámara de condensación de humedad permanente. Los tiempos de exposición fueron 100, 300 y 600 horas. La velocidad de corrosión se evaluó gravimétricamente, mediante la técnica de pérdida de peso. Se realizaron estudios de permeabilidad al oxígeno y al agua de películas libres de substrato, evaluación de la velocidad de corrosión de probetas sin pintar inmersas en soluciones salinas de los contaminantes seleccionados, conductividad de dichas soluciones salinas, solubilidad del oxígeno en las soluciones salinas, adherencia en seco y en húmedo a diferentes tiempos de exposición. Se aporta evidencia respecto al control ejercido en el proceso corrosivo por el oxígeno que permea a través de la película, mientras que la permeación de agua controla la pérdida de adherencia del recubrimiento. Ambas permeabilidades dependen de la naturaleza del recubrimiento y de su espesor. Se ha investigado la influencia de la naturaleza del contaminante en la intercara metal/pintura. La naturaleza del catión parece quedar enmascarada por el efecto definitivo del anión. La concentración salina ejerce asimismo un efecto importante en la corrosión subpelicular. ABSTRACT The main aim of this work is to study in depth the knowledge of underfilm corrosión induced by hydrosoluble contaminants at the metal/paint Ínterface. The saline contamination of the substrate is a common situation in practice: metallic surfaces use to be exposed to polluted atmospheres, previous cleaning of the metal with contaminated abrasives, etc. Total elimination of these contaminants is hard to obtain even with modern cleaning techniques. This research is focused in determining the effect of contaminant nature, coating nature and its thickness on the steel underfilm corrosión process. In this work we used two varnishes with different nature: polyurethane and vinyl; they were applied in three different thicknesses. The saline contaminants employed were: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03/ Ca(N03)2. The tests were carried out in a condensation humidity chamber. The period of exposure were 100, 300 and 600 hours. Corrosión rate was assessed by weight loss. Simultaneously, studies on oxygen and water permeability of free films, assessing on corrosión rate of uncoated samples immersed in saline solutions of the selected contaminants, conductivity of these solutions, oxygen solubility in saline solutions, wet and dry adhesión of the polyurethane varnish at different periods of exposure, were carried out. There is clear evidence about control on corrosión process of oxygen that passes through the coating, while the passing of water controls the loss of adhesión of the coating. Both, water and oxygen permeation, depend on the nature and thickness of the coating. It has been researched the inf luence of the nature of contaminant at the metal/paint interface. The nature of the catión seems to be "masked" by the definitive effect of the nature of anión. The saline concentration also exerts an important effect on underfilm corrosión.
Resumo:
In this paper we define the notion of an axiom dependency hypergraph, which explicitly represents how axioms are included into a module by the algorithm for computing locality-based modules. A locality-based module of an ontology corresponds to a set of connected nodes in the hypergraph, and atoms of an ontology to strongly connected components. Collapsing the strongly connected components into single nodes yields a condensed hypergraph that comprises a representation of the atomic decomposition of the ontology. To speed up the condensation of the hypergraph, we first reduce its size by collapsing the strongly connected components of its graph fragment employing a linear time graph algorithm. This approach helps to significantly reduce the time needed for computing the atomic decomposition of an ontology. We provide an experimental evaluation for computing the atomic decomposition of large biomedical ontologies. We also demonstrate a significant improvement in the time needed to extract locality-based modules from an axiom dependency hypergraph and its condensed version.
Resumo:
La dinámica estructural estudia la respuesta de una estructura ante cargas o fenómenos variables en el tiempo. En muchos casos, estos fenómenos requieren realizar análisis paramétricos de la estructura considerando una gran cantidad de configuraciones de diseño o modificaciones de la estructura. Estos cambios, ya sean en fases iniciales de diseño o en fases posteriores de rediseño, alteran las propiedades físicas de la estructura y por tanto del modelo empleado para su análisis, cuyo comportamiento dinámico se modifica en consecuencia. Un caso de estudio de este tipo de modificaciones es la supervisión de la integridad estructural, que trata de identificar la presencia de daño estructural y prever el comportamiento de la estructura tras ese daño, como puede ser la variación del comportamiento dinámico de la estructura debida a una delaminación, la aparición o crecimiento de grieta, la debida a la pérdida de pala sufrida por el motor de un avión en vuelo, o la respuesta dinámica de construcciones civiles como puentes o edificios frente a cargas sísmicas. Si a la complejidad de los análisis dinámicos requeridos en el caso de grandes estructuras se añade la variación de determinados parámetros en busca de una respuesta dinámica determinada o para simular la presencia de daños, resulta necesario la búsqueda de medios de simplificación o aceleración del conjunto de análisis que de otra forma parecen inabordables tanto desde el punto de vista del tiempo de computación, como de la capacidad requerida de almacenamiento y manejo de grandes volúmenes de archivos de datos. En la presente tesis doctoral se han revisado los métodos de reducción de elementos .nitos más habituales para análisis dinámicos de grandes estructuras. Se han comparado los resultados de casos de estudio de los métodos más aptos, para el tipo de estructuras y modificaciones descritas, con los resultados de aplicación de un método de reducción reciente. Entre los primeros están el método de condensación estática de Guyan extendido al caso con amortiguamiento no proporcional y posteriores implementaciones de condensaciones dinámicas en diferentes espacios vectoriales. El método de reducción recientemente presentado se denomina en esta tesis DACMAM (Dynamic Analysis in Complex Modal space Acceleration Method), y consiste en el análisis simplificado que proporciona una solución para la respuesta dinámica de una estructura, calculada en el espacio modal complejo y que admite modificaciones estructurales. El método DACMAM permite seleccionar un número reducido de grados de libertad significativos para la dinámica del fenómeno que se quiere estudiar como son los puntos de aplicación de la carga, localizaciones de los cambios estructurales o puntos donde se quiera conocer la respuesta, de forma que al implementar las modificaciones estructurales, se ejecutan los análisis necesarios sólo de dichos grados de libertad sin pérdida de precisión. El método permite considerar alteraciones de masa, rigidez, amortiguamiento y la adición de nuevos grados de libertad. Teniendo en cuenta la dimensión del conjunto de ecuaciones a resolver, la parametrización de los análisis no sólo resulta posible, sino que es también manejable y controlable gracias a la sencilla implementación del procedimiento para los códigos habituales de cálculo mediante elementos .nitos. En el presente trabajo se muestra la bondad y eficiencia del método en comparación con algunos de los métodos de reducción de grandes modelos estructurales, verificando las diferencias entre sí de los resultados obtenidos y respecto a la respuesta real de la estructura, y comprobando los medios empleados en ellos tanto en tiempo de ejecución como en tamaño de ficheros electrónicos. La influencia de los diversos factores que se tienen en cuenta permite identificar los límites y capacidades de aplicación del método y su exhaustiva comparación con los otros procedimientos. ABSTRACT Structural dynamics studies the response of a structure under loads or phenomena which vary over time. In many cases, these phenomena require the use of parametric analyses taking into consideration several design configurations or modifications of the structure. This is a typical need in an engineering o¢ ce, no matter the structural design is in early or final stages. These changes modify the physical properties of the structure, and therefore, the finite element model to analyse it. A case study, that exempli.es this circumstance, is the structural health monitoring to predict the variation of the dynamical behaviour after damage, such as a delaminated structure, a crack onset or growth, an aircraft that suffers a blade loss event or civil structures (buildings or bridges) under seismic loads. Not only large structures require complex analyses to appropriately acquire an accurate solution, but also the variation of certain parameters. There is a need to simplify the analytical process, in order to bring CPU time, data .les, management of solutions to a reasonable size. In the current doctoral thesis, the most common finite element reduction methods for large structures are reviewed. Results of case studies are compared between a recently proposed method, herein named DACMAM (Dynamic Analysis in Complex Modal space Acceleration Method), and different condensation methods, namely static or Guyan condensation and dynamic condensation in different vectorial spaces. All these methods are suitable for considering non-classical damping. The reduction method DACMAM consist of a structural modification in the complex modal domain which provides a dynamic response solution for the reduced models. This process allows the selection of a few degrees of freedom that are relevant for the dynamic response of the system. These d.o.f. are the load application points, relevant structural points or points in which it is important to know the response. Consequently, an analysis with structural modifications implies only the calculation of the dynamic response of the selected degrees of freedom added, but with no loss of information. Therefore, mass, stiffness or damping modifications are easily considered as well as new degrees of freedom. Taking into account the size of the equations to be solved, the parameterization of the dynamic solutions is not only possible, but also manageable and controllable due to the easy implementation of the procedure in the standard finite element solvers. In this thesis, the proposed reduction method for large structural models is compared with other published model order reduction methods. The comparison shows and underlines the efficiency of the new method, and veri.es the differences in the response when compared with the response of the full model. The CPU time, the data files and the scope of the parameterization are also addressed.