4 resultados para BLOOD-SUGAR
em Universidad Politécnica de Madrid
Resumo:
— In 2000, according to the World Health Organization, at least 171 million people, 2.8% of the population worldwide, suffered from diabetes. The Centres for Disease Control has defined it as an epidemic disease. Its incidence is increasing rapidly, and it is estimated that by 2030 this number will almost double. Diabetes mellitus occurs throughout the world, but is more common (especially type 2) in the more developed countries. Diabetes is a chronic condition that occurs when pancreas does not assure enough insulin secretion or when the body does not consume the insulin produced. Insulin is a hormone that regulates blood sugar. The effect of uncontrolled diabetes is the hyperglycaemia (blood sugar), which eventually seriously damage many organs and systems, especially the nerves and blood vessels. Diabetes type 2 (most common type of diabetes) is highly correlated with elderly people, obesity or overweight. Promoting a healthy lifestyle helps patients to improve their quality of life and in many cases to avoid complications related to the disease. This paper is intended to describe an iPhone-based application for self-management of type 2 diabetic patients, which allow them improving their lifestyle through healthy diet, physical activity and education
Resumo:
La diabetes mellitus es una enfermedad que se caracteriza por la nula o insuficiente producción de insulina, o la resistencia del organismo a la misma. La insulina es una hormona que ayuda a que la glucosa (por ejemplo la obtenida a partir de los alimentos ingeridos) llegue a los tejidos periféricos y al sistema nervioso para suministrar energía. Hoy en día la tecnología actual permite abordar el desarrollo del llamado “páncreas endocrino artificial”, que consta de un sensor continuo de glucosa subcutánea, una bomba de infusión subcutánea de insulina y un algoritmo de control en lazo cerrado que calcule la dosis de insulina requerida por el paciente en cada momento, según la medida de glucosa obtenida por el sensor y según unos objetivos. El mayor problema que presentan los sistemas de control en lazo cerrado son los retardos, el sensor de glucosa subcutánea mide la glucosa del líquido intersticial, que representa la que hubo en la sangre un tiempo atrás, por tanto, un cambio en los niveles de glucosa en la sangre, debidos por ejemplo, a una ingesta, tardaría un tiempo en ser detectado por el sensor. Además, una dosis de insulina suministrada al paciente, tarda un tiempo aproximado de 20-30 minutos para la llegar a la sangre. Para evitar trabajar en la medida que sea posible con estos retardos, se intenta predecir cuál será el nivel de glucosa en un futuro próximo, para ello se utilizara un predictor de glucosa subcutánea, con la información disponible de glucosa e insulina. El objetivo del proyecto es diseñar una metodología para estimar el valor futuro de los niveles de glucosa obtenida a partir de un sensor subcutáneo, basada en la identificación recursiva del sistema glucorregulatorio a través de modelos lineales y determinando un horizonte de predicción óptimo de trabajo y analizando la influencia de la insulina en los resultados de la predicción. Se ha implementado un predictor paramétrico basado en un modelo autorregresivo ARX que predice con mejor precisión y con menor RMSE que un predictor ZOH a un horizonte de predicción de treinta minutos. Utilizar información relativa a la insulina no tiene efecto en la predicción. El preprocesado, postprocesado y el tratamiento de la estabilidad tienen un efecto muy beneficioso en la predicción. Diabetes mellitusis a group of metabolic diseases in which a person has high blood sugar, either because the body does not produce enough insulin, or because cells do not respond to the insulin produced. The insulin is a hormone that helps the glucose to reach to outlying tissues and the nervous system to supply energy. Nowadays, the actual technology allows raising the development of the “artificial endocrine pancreas”. It involves a continuous glucose sensor, an insulin bump, and a full closed loop algorithm that calculate the insulin units required by patient at any time, according to the glucose measure obtained by the sensor and any target. The main problem of the full closed loop systems is the delays, the glucose sensor measures the glucose in the interstitial fluid that represents the glucose was in the blood some time ago. Because of this, a change in the glucose in blood would take some time to be detected by the sensor. In addition, insulin units administered by a patient take about 20-30 minutes to reach the blood stream. In order to avoid this effect, it will try to predict the glucose level in the near future. To do that, a subcutaneous glucose predictor is used to predict the future glucose with the information about insulin and glucose. The goal of the proyect is to design a method in order to estimate the future valor of glucose obtained by a subcutaneous sensor. It is based on the recursive identification of the regulatory system through the linear models, determining optimal prediction horizon and analyzing the influence of insuline on the prediction results. A parametric predictor based in ARX autoregressive model predicts with better precision and with lesser RMSE than ZOH predictor in a thirty minutes prediction horizon. Using the relative insulin information has no effect in the prediction. The preprocessing, the postprocessing and the stability treatment have many advantages in the prediction.
Resumo:
We present a fast, highly sensitive, and efficient potentiometric glucose biosensor based on functionalized InN quantum-dots (QDs). The InN QDs are grown by molecular beam epitaxy. The InN QDs are bio-chemically functionalized through physical adsorption of glucose oxidase (GOD). GOD enzyme-coated InN QDs based biosensor exhibits excellent linear glucose concentration dependent electrochemical response against an Ag/AgCl reference electrode over a wide logarithmic glucose concentration range (1 × 10−5 M to 1 × 10−2 M) with a high sensitivity of 80 mV/decade. It exhibits a fast response time of less than 2 s with good stability and reusability and shows negligible response to common interferents such as ascorbic acid and uric acid. The fabricated biosensor has full potential to be an attractive candidate for blood sugar concentration detection in clinical diagnoses.
Resumo:
La diabetes mellitus es una enfermedad que se caracteriza por la nula o insuficiente producción de insulina, o la resistencia del organismo a la misma. La insulina es una hormona que ayuda a que la glucosa llegue a los tejidos periféricos y al sistema nervioso para suministrar energía. Actualmente existen dos tipos de terapias aplicada en tejido subcutáneo: mediante inyección múltiple realizada con plumas, y la otra es mediante infusión continua de insulina por bomba (CSII). El mayor problema de esta terapia son los retardos por la absorción, tanto de los carbohidratos como de la insulina, y los retardos introducidos por el sensor subcutáneo de glucosa que mide la glucosa del líquido intersticial, lo deseable es controlar la glucosa en sangre. Para intentar independizar al paciente de su enfermedad se está trabajando en el desarrollo del páncreas endocrino artificial (PEA) que dotaría al paciente de una bomba de insulina, un sensor de glucosa y un controlador, el cual se encargaría de la toma de decisiones de las infusiones de insulina. Este proyecto persigue el diseño de un regulador en modo de funcionamiento en CL, con el objetivo de conseguir una regulación óptima del nivel de glucosa en sangre. El diseño de dicho regulador va a ser acometido utilizando la teoría del control por modelo interno (IMC). Esta teoría se basa en la idea de que es necesario realimentar la respuesta de un modelo aproximado del proceso que se quiere controlar. La salida del modelo, comparada con la del proceso real nos da la incertidumbre del modelo de la planta, frente a la planta real. Dado que según la teoría del modelo interno, estas diferencias se dan en las altas frecuencias, la teoría IMC propone un filtro paso bajo como regulador en serie con la inversa del modelo de la planta para conseguir el comportamiento deseado. Además se pretende implementar un Predictor Smith para minimizar los efectos del retardo de la medida del sensor. En el proyecto para conseguir la viabilidad del PEA se ha adaptado el controlador IMC clásico utilizando las ganancias estáticas de un modelo de glucosa, a partir de la ruta subcutánea de infusión y la vía subcutánea de medida. El modo de funcionamiento del controlador en SCL mejora el rango de normoglucemia, necesitando la intervención del paciente indicando anticipadamente el momento de las ingestas al controlador. El uso de un control SCL con el Predictor de Smith mejora los resultados pues se añade al controlador una variable sobre las ingestas con la participación del paciente. ABSTRACT. Diabetes mellitus is a group of metabolic diseases in which a person has high blood sugar, due to the body does not produce enough insulin, or because cells do not respond to the insulin produced. The insulin is a hormone that helps the glucose to reach to outlying tissues and the nervous system to supply energy. There are currently two types of therapies applied in subcutaneous tissue: the first one consists in using the intensive therapy with an insulin pen, and the other one is by continuous subcutaneous insulin infusion (CSII). The biggest problems of this therapy are the delays caused by the absorption of carbohydrates and insulin, and the delays introduced by the subcutaneous glucose sensor that measures glucose from interstitial fluid, it is suitable to control glucose blood. To try to improve these patients quality of life, work is being done on the development of an artificial endocrine pancreas (PEA) consisting of a subcutaneous insulin pump, a subcutaneous glucose sensor and an algorithm of glucose control, which would calculate the bolus that the pump would infuse to patient. This project aims to design a controller for closed-loop therapy, with the objective of obtain an optimal regulation of blood glucose level. The design of this controller will be formed using the theory of internal model control (IMC). This theory is based on the uncertainties given by a model to feedback the system control. Output model, in comparison with the actual process gives the uncertainty of the plant model, compared to the real plant. Since the theory of the internal model, these differences occur at high frequencies, the theory proposes IMC as a low pass filter regulator in series with the inverse model of the plant to get the required behavior. In addition, it will implement a Smith Predictor to minimize the effects of the delay measurement sensor. The project for the viability of PEA has adapted the classic IMC controller using the gains static of glucose model from the subcutaneous infusion and subcutaneous measuring. In simulation the SemiClosed-Loop controller get on the normoglycemia range, requiring patient intervention announce the bolus priming connected to intakes. Using an SCL control with the Smith Predictor improves the outcome because a variable about intakes is added to the controller through patient intervention.