5 resultados para Aerospace instrumentation
em Universidad Politécnica de Madrid
Resumo:
Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.
Resumo:
Structural Health Monitoring (SHM) requires integrated "all in one" electronic devices capable of performing analysis of structural integrity and on-board damage detection in aircraft?s structures. PAMELA III (Phased Array Monitoring for Enhanced Life Assessment, version III) SHM embedded system is an example of this device type. This equipment is capable of generating excitation signals to be applied to an array of integrated piezoelectric Phased Array (PhA) transducers stuck to aircraft structure, acquiring the response signals, and carrying out the advanced signal processing to obtain SHM maps. PAMELA III is connected with a host computer in order to receive the configuration parameters and sending the obtained SHM maps, alarms and so on. This host can communicate with PAMELA III through an Ethernet interface. To avoid the use of wires where necessary, it is possible to add Wi-Fi capabilities to PAMELA III, connecting a Wi-Fi node working as a bridge, and to establish a wireless communication between PAMELA III and the host. However, in a real aircraft scenario, several PAMELA III devices must work together inside closed structures. In this situation, it is not possible for all PAMELA III devices to establish a wireless communication directly with the host, due to the signal attenuation caused by the different obstacles of the aircraft structure. To provide communication among all PAMELA III devices and the host, a wireless mesh network (WMN) system has been implemented inside a closed aluminum wingbox. In a WMN, as long as a node is connected to at least one other node, it will have full connectivity to the entire network because each mesh node forwards packets to other nodes in the network as required. Mesh protocols automatically determine the best route through the network and can dynamically reconfigure the network if a link drops out. The advantages and disadvantages on the use of a wireless mesh network system inside closed aerospace structures are discussed.
Resumo:
Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.
Resumo:
A theory is developed of an electrostatic probe in a fully-ionized plasma in the presence of a strong magnetic field. The ratio of electron Larmor radius to probe transverse dimension is assumed to be small. Poisson's equation, together with kinetic equations for ions and electrons are considered. An asymptotic perturbation method of multiple scales is used by considering the characteristic lengths appearing in the problem. The leading behavior of the solution is found. The results obtained appear to apply to weaker fields also, agreeing with the solutions known in the limit of no magnetic field. The range of potentials for wich results are presented is limited. The basic effects produced by the field are a depletion of the plasma near the probe and a non-monotonic potential surrounding the probe. The ion saturation current is not changed but changes appear in both the floating potential Vf and the slope of the current-voltage diagram at Vf. The transition region extends beyond the space potential Vs,at wich point the current is largely reduced. The diagram does not have an exponential form in this region as commonly assumed. There exists saturation in electron collection. The extent to which the plasma is disturbed is determined. A cylindrical probe has no solution because of a logarithmic singularity at infinity. Extensions of the theory are considered.
Resumo:
Airbus designs and industrializes aircrafts using Concurrent Engineering techniques since decades. The introduction of new PLM methods, procedures and tools, and the need to reduce time-to-market, led Airbus Military to pursue new working methods. Traditional Engineering works sequentially. Concurrent Engineering basically overlaps tasks between teams. Collaborative Engineering promotes teamwork to develop product, processes and resources from the conceptual phase to the start of the serial production. The CALIPSO-neo pilot project was launched to support the industrialization process of a medium size aerostructure. The aim is to implement the industrial Digital Mock-Up (iDMU) concept and its exploitation to create shop floor documentation. In a framework of a collaborative engineering strategy, the project is part of the efforts to deploy Digital Manufacturing as a key technology for the industrialization of aircraft assembly lines. This paper presents the context, the conceptual approach and the methodology adopted.