4 resultados para AM Museums (General). Collectors and collecting (General)
em Universidad Politécnica de Madrid
Resumo:
The supercritical Rankine power cycle offers a net improvement in plant efficiency compared with a subcritical Rankine cycle. For fossil power plants the minimum supercritical steam turbine size is about 450MW. A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013, confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a line-focus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt Hitec XL. To isolate solar field from high pressure supercritical water power cycle, an intermediate heat exchanger was installed between linear solar collectors and balance of plant. Due to receiver selective coating temperature limitations, turbine inlet temperature was fixed 550ºC. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plantconfiguration), and in the subcritical plant configuration (~40% net plant efficiency). Regarding the balance of plant configuration, direct reheating was adopted as the optimum solution to avoid any intermediate heat exchanger. One direct reheating stage between high pressure turbine and intermediate pressure turbine is the common practice; however, General Electric ultrasupercritical(350 bar) fossil power plants also considered doubled-reheat applications. In this study were analyzed heat balances with single-reheat, double-reheat and even three reheating stages. In all cases were adopted the proper reheating solar field configurations to limit solar collectors pressure drops. As main conclusion, it was confirmed net plant efficiency improvements in supercritical Rankine line-focus (parabolic or linear Fresnel) solar plant configurations are mainly due to the following two reasons: higher number of feed-water preheaters (up to seven)delivering hotter water at solar field inlet, and two or even three direct reheating stages (550ºC reheating temperature) in high or intermediate pressure turbines. However, the turbine manufacturer should confirm the equipment constrains regarding reheating stages and number of steam extractions to feed-water heaters.
Resumo:
Esta Tesis plantea la pregunta de si el uso de morteros con parafinas microencapsuladas combinado con colectores solares térmicos puede reducir el consumo de energías convencionales, en un sistema tradicional de suelo radiante. Se pretende contribuir al conocimiento acerca del efecto que produce en el edificio, el calor latente acumulado en suelos radiantes, utilizando morteros de cemento Portland con material de cambio de fase (PCM), en conjunto con la energía solar. Para cumplir con este propósito, la investigación se desarrolla considerando diversos aspectos. En primer lugar, se revisa y analiza la documentación disponible en la actualidad, de almacenamiento de energía mediante calor latente en la construcción, y en particular la aplicación de microcápsulas de PCM en morteros y suelos radiantes. También se revisa la documentación relacionada con la aplicación de la energía solar térmica y en suelo radiante. Se analiza la normativa vigente respecto al material, a los colectores solares y al suelo radiante. Se verifica que no hay normativa relacionada con mortero-PCM, debido a esto se aplica en la investigación una adaptación de la existente. La fase experimental desarrollada esta principalmente dirigida a la cuantificación, caracterización y evaluación de las propiedades físicas, mecánicas y térmicas del mortero de cemento Portland con parafinas microencapsuladas. Los resultados obtenidos y su análisis, permiten conocer el comportamiento de este tipo de morteros, con las diferentes variables aplicadas en la investigación. Además, permite disponer de la información necesaria, para crear una metodología para el diseño de morteros con parafina microencapsulada, tanto del punto de vista de su resistencia a la compresión y contenido de PCM, como de su comportamiento térmico como acumulador de calor. Esto se logra procesando la información obtenida y generando modelos matemáticos, para dosificar mezclas, y predecir la acumulación de calor en función de su composición. Se determinan los tipos y cantidades de PCM, y el cemento más adecuado. Se obtienen importantes conclusiones respecto a los aspectos constructivos a considerar en la aplicación de morteros con PCM, en suelo radiante. Se analiza y evalúa la demanda térmica que se puede cubrir con el suelo radiante, utilizando morteros con parafina microencapsulada, a través de la acumulación de energía solar producida por colectores solares, para condiciones climáticas, técnicas y tipologías constructivas específicas. Se determina que cuando los paneles cubren más de 60 % de la demanda por calefacción, se puede almacenar en los morteros con PCM, el excedente generado durante el día. Se puede cubrir la demanda de acumulación de energía con los morteros con PCM, en la mayoría de los casos analizados. Con esto, se determina que el uso de morteros con PCM, aporta a la eficiencia energética de los edificios, disminuyendo el consumo de energías convencionales, reemplazándola por energía solar térmica. En esta investigación, el énfasis está en las propiedades del material mortero de cemento-PCM y en poder generar metodologías que faciliten su uso. Se aborda el uso de la energía solar, para verificar que es posible su acumulación en morteros con PCM aplicados en suelo radiante, posibilitando el reemplazo de energías convencionales. Quedan algunos aspectos de la aplicación de energía solar a suelo radiante con morteros con PCM, que no han sido tratados con la profundidad que requieren, y que resultan interesantes de evaluar en este tipo de aplicaciones constructivas, como entre otros, los relacionados con la cuantificación de los ahorros de energía en las diferentes estaciones del año, de la estabilización de temperaturas internas, su análisis de costo y la optimización de este tipo de sistemas para utilización en verano, los que dan pie para otras Tesis o proyectos de investigación. ABSTRACT This Thesis proposes the question of whether the use of mortars with microencapsulated paraffin combined with solar thermal collectors can reduce conventional energy consumption in a traditional heating floor system. It aims to contribute to knowledge about the effect that it has on the building, the latent heat accumulated in heating floor, using Portland cement mortars with phase change material (PCM), in conjunction with solar energy. To fulfill this purpose, the research develops it considering various aspects. First, it reviews and analyzes the documentation available today, about energy storage by latent heat in the building, and in particular the application of PCM microcapsules in mortars and heating floors. It also reviews the documentation related to the application of solar thermal energy and heating floor. Additionally, it analyzes the current regulations regarding to material, solar collectors and heating floors. It verifies that there aren’t regulations related to PCM mortar, due to this, it applies an adaptation in the investigation. The experimental phase is aimed to the quantification, mainly, characterization and evaluation of physical, mechanical and thermal properties of Portland cement mortar with microencapsulated paraffin. The results and analysis, which allow us to know the behavior of this type of mortars with different variables applied in research. It also allows having the information necessary to create a methodology for designing mortars with microencapsulated paraffin, both from the standpoint of its resistance to compression and PCM content, and its thermal performance as a heat accumulator. This accomplishes by processing the information obtained, and generating mathematical models for dosing mixtures, and predicting heat accumulation depending on their composition. The research determines the kinds and amounts of PCM, and the most suitable cement. Relevant conclusions obtain it regarding constructive aspects to consider in the implementation of PCM mortars in heating floor. Also, it analyzes and evaluates the thermal demand that it can be covered in heating floor using microencapsulated paraffin mortars, through the accumulation of solar energy produced by solar collectors to weather conditions, technical and specific building typologies. It determines that if the panels cover more than 60% of the demand for heating, the surplus generated during the day can be stored in PCM mortars. It meets the demand of energy storage with PCM mortars, in most of the cases analyzed. With this, it determines that the use of PCM mortars contributes to building energy efficiency, reducing consumption of conventional energy, replacing it with solar thermal energy. In this research approaches the use of solar energy to determine that it’s possible to verify its accumulation in PCM mortars applied in heating floor, enabling the replacement of conventional energy. The emphasis is on material properties of PCM mortar and, in order to generate methodologies to facilitate their use. There are some aspects of solar energy application in PCM mortars in heating floor, which have not been discussed with the depth required, and that they are relevant to evaluate in this kind of construction applications, including among others: the applications related to the energy savings quantification in different seasons of the year, the stabilizing internal temperatures, its cost analysis and optimization of these systems for use in summer, which can give ideas for other thesis or research projects.
Resumo:
Este proyecto surge de la búsqueda de un campo de aplicación de las Redes de Sensores Inalámbricos, WSN, aplicadas a la vida cotidiana. Dicha aplicación consistirá en un sistema de gestión de alumbrado público a través del cual se buscará una reducción del consumo energético y del gasto económico, así como una gestión en tiempo de real de la operativa del alumbrado. Para ello se desarrollará un sistema basado en nodos instalados en farolas, los cuales se comunicarán entre sí para funcionar de la forma más optimizada posible, complementándose todo ello con un “nodo base”, que se encargará de servir de nexo entre la red y los diferentes elementos necesarios para la configuración de los nodos y la recogida de información. Esta información servirá para que una página web pueda mostrar al usuario final toda la información necesaria para tener un control sobre el estado actual de funcionamiento de cada una de las farolas, control del consumo, así como detección de averías. En este proyecto se describen las tecnologías actuales relacionadas con el campo de las WSN y los sensores, presentando aplicaciones que en la actualidad se encuentran desplegadas. Se expone también una propuesta real de despliegue presentada al Ayuntamiento de una localidad, Pedro Muñoz, para implementar un proyecto piloto en varias de sus calles. Se describe el entorno, tanto hardware como software, explicando los algoritmos utilizados para las asociaciones entre nodos, diagramas de funcionamiento en las distintas fases de la que está compuesta la operativa de los nodos, la codificación de los programas que se necesitan ejecutar para el correcto funcionamiento del sistema. Por último, debido a que el campo de las WSN está en constante evolución, se presentarán diversas ideas para implementar diversas mejoras que pudieran ser desplegadas en un futuro, ampliando la oferta de aplicaciones a ofrecer al usuario final. ABSTRACT. This project results from the development for an application field of wireless Sensor Networks (WSN), applied to daily life. That application will consist of a system of street lighting management, through which it will seek a reduction in energy consumption and economic cost, and a real-time management of the operative of the street lighting. To do this, a system based on nodes installed in streetlights will be developed. These nodes will communicate with each other to operate in the most optimized way possible, complementing all with a Base-station, which will act as a link between the network and the components required for configuring the nodes and collecting data from them. This information will help a website to show the end user all the information needed to have a control on the current operating status of each of the streetlights, consumption control and troubleshooting. To this end, this project will describe the current technologies related to the field of WSN and sensors, presenting applications that are currently deployed. It will be also exposed a real proposal submitted to a city council to deploy a pilot project in many of its streets. Will be described the environment, both hardware and software, explaining the algorithms used for the associations between nodes, operating diagrams in the different phases of the nodes operation, and the coding of programs that are needed for proper system performance. Finally, because the field of WSN is in constant evolution, will be presented different ideas to implement various improvements which could be deployed in the future, extending the range of applications to provide to end-users.
Resumo:
El consumo de energía es responsable de una parte importante de las emisiones a la atmósfera de CO2, que es uno de los principales causantes del efecto invernadero en nuestro planeta. El aprovechamiento de la energía solar para la producción de agua caliente, permite economizar energía y disminuir el impacto del consumo energético sobre el medio ambiente y por tanto un menor impacto medioambiental. El objetivo de la presente investigación consiste en estudiar el aprovechamiento solar para el calentamiento de los fangos en los digestores anaerobios mediante agua caliente circulando en el interior de un serpentín que rodea la superficie de dicho digestor, como apoyo a los métodos convencionales del calentamiento de fangos como la resistencia eléctrica o el intercambiador de calor mediante la energía obtenida por el gas metano producido en la digestión anaerobia. Para el estudio se utilizaron 3 digestores, dos delos cuales se calentaron con agua caliente en el interior de un serpentín (uno aislado mediante una capa de fibra de vidrio y poliuretano y otro sin aislar).El tercer digestor no tenía calentamiento exterior con el objetivo de observar su comportamiento y comparar su evolución con el resto de los digestores .La comparación de los digestores 1 y 2 nos permitió estudiar la conveniencia de proveer de aislamiento al digestor. La transferencia de calor mediante serpentín de cobre dio valores comprendidos entre 83 y 92%. La aplicación de la instalación a una depuradora a escala real para mantenimiento en el interior del digestor a T=32ºC en diferentes climas: climas templados, cálidos y fríos, consistió en el cálculo de la superficie de colectores solares y superficie de serpentín necesario para cubrir las necesidades energéticas anuales de dicho digestor, así como el estudio de rentabilidad de la instalación, dando los mejores resultados para climas cálidos con períodos de retorno de 12 años y una tasa interna de rentabilidad (TIR) del 16% obteniendo una cobertura anual del 79% de las necesidades energéticas con energía solar térmica. Energy consumption accounts for a significant part of the emissions of CO2, which is one of the main causes of the greenhouse effect on our planet. The use of solar energy for hot water production. can save energy and reduce the impact of energy consumption on the environment and therefore a reduced environmental impact. The objective of this research is to study the solar utilization for heating the sludge in anaerobic digesters by hot water circulating inside a coil surrounding the surface of digester, to support conventional heating methods sludge as the electrical resistance or heat exchanger by energy generated by the methane gas produced in the anaerobic digestion. To study 3 digesters used two models which are heated with hot water within a coil (one insulated by a layer of fiberglass and polyurethane and other uninsulated) .The third digester had no external heating in order to observe their behavior and compare their evolution with the rest of the .The comparison digesters digesters 1 and 2 allowed us to study the advisability of providing insulation to the digester. Heat transfer through copper coil gave values between 83 and 92%. The installation application to a treatment for maintaining full scale within the digester at T = 32ºC in different climates: temperate, warm and cold climates, consisted of calculating the surface area of solar collectors and coil required to cover the annual energy needs of the digester, and the study of profitability of the installation, giving the best results for hot climates with return periods of 12 years and an internal rate of return (IRR) of 16% achieving an annual coverage of 79 % of energy needs with solar energy.