7 resultados para 140.3480

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In overhead conductor rail lines, aluminium beams are usually mounted with support spacing between 8 and 12 meters, to limit the maximum vertical deflection in the center of the span. This small support spacing limits the use of overhead conductor rail to tunnels, therefore it has been used almost exclusively in metropolitan networks, with operation speeds below 110 km/h. Nevertheless, due to the lower cost of maintenance required for this electrification system, some railway administrations are beginning to install it in some tunnels on long-distance lines, requesting higher operation speeds [1]. Some examples are the Barcelona and Madrid suburban networks (Spain), and recent lines in Turkey and Malaysia. In order to adapt the design of the overhead conductor for higher speeds (V > 160 km/h), particular attention must be paid to the geometry of the conductor rail in critical zones as overlaps, crossings and, especially, transitions between conductor rail and conventional catenary, since the use of overhead conductor rail is limited to tunnels, as already mentioned. This paper describes simulation techniques developed in order to take into account these critical zones. Furthermore, some specific simulations results are presented that have been used to analyze and optimizes the geometry of this special zones to get a better current collection quality, in a real suburban network. This paper presents the work undertaken by the Railways Technology Research Centre (CITEF), having over 10 years of experience in railways research [1-4].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge of the uncertainty of measurement of testing results is important when results have to be compared with limits and specifications. In the measurement of sound insulation following standards UNE EN ISO 140-4 the uncertainty of the final magnitude is mainly associated to the average sound pressure levels L1 and L2 measured. A parameter that allows us to quantify the spatial variation of the sound pressure level is the standard deviation of the pressure levels measured at different points of the room. In this work, for a wide number of measurements following standards UNE EN ISO 140-4 we analyzed qualitatively the behaviour of the standard deviation for L1 and L2. The study of sound fields in enclosed spaces is very difficult. There are a wide variety of rooms with different sound fields depending on factors as volume, geometry and materials. In general, we observe that the L1 and L2 standard deviations contain peaks and dips independent on characteristics of the rooms at single frequencies that could correspond to critical frequencies of walls, floors and windows or even to temporal alterations of the sound field. Also, in most measurements according to UNE EN ISO 140-4 a large similitude between L1 and L2 standard deviation is found. We believe that such result points to a coupled system between source and receiving rooms, mainly at low frequencies the shape of the L1 and L2 standard deviations is comparable to the velocity level standard deviation on a wall

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En los ensayos de aislamiento acústico según normas UNE EN ISO 140-4 y 140-5 el valor de L2 es un promedio espacio-temporal de los niveles de presión sonora medidos en diferentes posiciones de la sala receptora. La desviación estándar de estos valores se puede considerar como una medida de la uniformidad del campo sonoro en el recinto. Se analiza este parámetro en función de la frecuencia y se propone un cálculo teórico del mismo como una incertidumbre combinada de la desviación estándar derivada de modelos teóricos centrados en la geometría del recinto y la desviación estándar asociada a la vibración de la pared separadora

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El apartado <4.2 Altavoz> de la Norma Internacional UNE-EN ISO 140-5 [1] especifica que la directividad del altavoz usado en el ensayo debe asegurar en todas las bandas de frecuencias de interés, unas diferencias de nivel locales inferiores a 5dB (o a 10 dB para fachadas de dimensiones mayores a 5m), medidas en campo libre, sobre una superficie del mismo tamaño y orientación que la pared o elemento a ensayar. Este requisito debe verificarse en unas bandas de frecuencia de interés que sean como mínimo los tercios de octava desde 100Hz hasta 3150Hz, y preferiblemente desde 50Hz hasta 5kHz. Desde hace unos años, en el Laboratorio de sonido de la EUIT de Telecomunicación de la Universidad Politécnica de Madrid, los autores han implementado un método en el que, a partir de las medidas de directividad en cámara anecoica de la fuente sonora a ensayar, se calcula el campo sonoro directo sobre una superficie ficticia que representa un elemento de fachada en la misma disposición que se indica en la norma ICO 140-5 y con unas dimensiones según se requieran en el procedimiento. También se estima la dimensión horizontal máxima ΔXmax de una fachada rectangular en relación de aspecto fija que permite verificar la norma con los criterios de 5dB y 10dB de diferencias máximas de niveles directos en dicha fachada. En esta ponencia se detalla el procedimiento anterior. ABSTRACT. The Section "4.2 loudspeaker" of the UNE-EN ISO 140-5 International Standard: "Field measurements of airborne sound insulation of façade elements and façades", specifies that the directivity of the loudspeaker used in the test must ensure in all frequency bands of interest, local level differences less than 5dB (or 10dB for façade dimensions greater than 5m), measured in free field over an area of the same size and orientation as the wall or element to be tested. This requirement must be verified in the frequency bands of interest which are, at least, the third octave bands from 100Hz to 3150Hz, preferably from 50Hz to 5kHz. In recent years, in the Laboratory of Sound of the EUIT Telecomunicación (Universidad Politécnica de Madrid), the authors have implemented a method that, from directivity measurements of loudspeakers performed in the anechoic room, the direct sound field on a surface in the same layout as indicated in the ISO standard is calculated. It is also estimated the maximum horizontal dimension Δxmax of a rectangular façade for each aspect ratio which verify the standard criteria of either 5dB or 10dB for the maximum differences of direct levels in the façade. This paper details the procedure above introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new verification procedure for sound source coverage according to ISO 140?5 requirements. The ISO 140?5 standard applies to the measurement of façade insulation and requires a sound source able to achieve a sufficiently uniform sound field in free field conditions on the façade under study. The proposed method involves the electroacoustic characterisation of the sound source in laboratory free field conditions (anechoic room) and the subsequent prediction by computer simulation of the sound free field radiated on a rectangular surface equal in size to the façade being measured. The loudspeaker is characterised in an anechoic room under laboratory controlled conditions, carefully measuring directivity, and then a computer model is designed to calculate the acoustic free field coverage for different loudspeaker positions and façade sizes. For each sound source position, the method provides the maximum direct acoustic level differences on a façade specimen and therefore determines whether the loudspeaker verifies the maximum allowed level difference of 5 dB (or 10 dB for façade dimensions greater than 5 m) required by the ISO standard. Additionally, the maximum horizontal dimension of the façade meeting the standard is calculated and provided for each sound source position, both with the 5 dB and 10 dB criteria. In the last section of the paper, the proposed procedure is compared with another method used by the authors in the past to achieve the same purpose: in situ outdoor measurements attempting to recreate free field conditions. From this comparison, it is concluded that the proposed method is able to reproduce the actual measurements with high accuracy, for example, the ground reflection effect, at least at low frequencies, which is difficult to avoid in the outdoor measurement method, and it is fully eliminated with the proposed method to achieve the free field requisite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The International Standard ISO 140-5 on field measurements of airborne sound insulation of façades establishes that the directivity of the measurement loudspeaker should be such that the variation in the local direct sound pressure level (ΔSPL) on the sample is ΔSPL < 5 dB (or ΔSPL < 10 dB for large façades). This condition is usually not very easy to accomplish nor is it easy to verify whether the loudspeaker produces such a uniform level. Direct sound pressure levels on the ISO standard façade essentially depend on the distance and directivity of the loudspeaker used. This paper presents a comprehensive analysis of the test geometry for measuring sound insulation and explains how the loudspeaker directivity, combined with distance, affects the acoustic level distribution on the façade. The first sections of the paper are focused on analysing the measurement geometry and its influence on the direct acoustic level variations on the façade. The most favourable and least favourable positions to minimise these direct acoustic level differences are found, and the angles covered by the façade in the reference system of the loudspeaker are also determined. Then, the maximum dimensions of the façade that meet the conditions of the ISO 140-5 standard are obtained for the ideal omnidirectional sound source and the piston radiating in an infinite baffle, which is chosen as the typical radiation pattern for loudspeakers. Finally, a complete study of the behaviour of different loudspeaker radiation models (such as those usually utilised in the ISO 140-5 measurements) is performed, comparing their radiation maps on the façade for searching their maximum dimensions and the most appropriate radiation configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente son una práctica común los procesos de normalización de métodos de ensayo y acreditación de laboratorios, ya que permiten una evaluación de los procedimientos llevados a cabo por profesionales de un sector tecnológico y además permiten asegurar unos mínimos de calidad en los resultados finales. En el caso de los laboratorios de acústica, para conseguir y mantener la acreditación de un laboratorio es necesario participar activamente en ejercicios de intercomparación, utilizados para asegurar la calidad de los métodos empleados. El inconveniente de estos ensayos es el gran coste que suponen para los laboratorios, siendo en ocasiones inasumible por estos teniendo que renunciar a la acreditación. Este Proyecto Fin de Grado se centrará en el desarrollo de un Laboratorio Virtual implementado mediante una herramienta software que servirá para realizar ejercicios de intercomparación no presenciales, ampliando de ese modo el concepto e-comparison y abriendo las bases a que en un futuro este tipo de ejercicios no presenciales puedan llegar a sustituir a los llevados a cabo actualmente. En el informe primero se hará una pequeña introducción, donde se expondrá la evolución y la importancia de los procedimientos de calidad acústica en la sociedad actual. A continuación se comentará las normativas internacionales en las que se soportará el proyecto, la norma ISO 145-5, así como los métodos matemáticos utilizados en su implementación, los métodos estadísticos de propagación de incertidumbres especificados por la JCGM (Joint Committee for Guides in Metrology). Después, se hablará sobre la estructura del proyecto, tanto del tipo de programación utilizada en su desarrollo como la metodología de cálculo utilizada para conseguir que todas las funcionalidades requeridas en este tipo de ensayo estén correctamente implementadas. Posteriormente se llevará a cabo una validación estadística basada en la comparación de unos datos generados por el programa, procesados utilizando la simulación de Montecarlo, y unos cálculos analíticos, que permita comprobar que el programa funciona tal y como se ha previsto en la fase de estudio teórico. También se realizará una prueba del programa, similar a la que efectuaría un técnico de laboratorio, en la que se evaluará la incertidumbre de la medida calculándola mediante el método tradicional, pudiendo comparar los datos obtenidos con los que deberían obtenerse. Por último, se comentarán las conclusiones obtenidas con el desarrollo y pruebas del Laboratorio Virtual, y se propondrán nuevas líneas de investigación futuras relacionadas con el concepto e-comparison y la implementación de mejoras al Laboratorio Virtual. ABSTRACT. Nowadays it is common practise to make procedures to normalise trials methods standards and laboratory accreditations, as they allow for the evaluation of the procedures made by professionals from a particular technological sector in addition to ensuring a minimum quality in the results. In order for an acoustics laboratory to achieve and maintain the accreditation it is necessary to actively participate in the intercomparison exercises, since these are used to assure the quality of the methods used by the technicians. Unfortunately, the high cost of these trials is unaffordable for many laboratories, which then have to renounce to having the accreditation. This Final Project is focused on the development of a Virtual Laboratory implemented by a software tool that it will be used for making non-attendance intercomparison trials, widening the concept of e-comparison and opening the possibility for using this type of non-attendance trials instead of the current ones. First, as a short introduction, I show the evolution and the importance today of acoustic quality procedures. Second, I will discuss the international standards, such as ISO 145-5, as well the mathematic and statistical methods of uncertainty propagation specified by the Joint Committee for Guides in Metrology, that are used in the Project. Third, I speak about the structure of the Project, as well as the programming language structure and the methodology used to get the different features needed in this acoustic trial. Later, a statistical validation will be carried out, based on comparison of data generated by the program, processed using a Montecarlo simulation, and analytical calculations to verify that the program works as planned in the theoretical study. There will also be a test of the program, similar to one that a laboratory technician would carry out, by which the uncertainty in the measurement will be compared to a traditional calculation method so as to compare the results. Finally, the conclusions obtained with the development and testing of the Virtual Laboratory will be discussed, new research paths related to e-comparison definition and the improvements for the Laboratory will be proposed.