7 resultados para 1050°
em Universidad Politécnica de Madrid
Resumo:
Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.
Resumo:
This paper presents some of the results of a method to determine the main reliability functions of concentrator solar cells. High concentrator GaAs single junction solar cells have been tested in an Accelerated Life Test. The method can be directly applied to multi-junction solar cells. The main conclusions of this test carried out show that these solar cells are robust devices with a very low probability of failure caused by degradation during their operation life (more than 30 years). The evaluation of the probability operation function (i.e. the reliability function R(t)) is obtained for two nominal operation conditions of these cells, namely simulated concentration ratios of 700 and 1050 suns. Preliminary determination of the Mean Time to Failure indicates a value much higher than the intended operation life time of the concentrator cells.
Resumo:
Using the Monte Carlo method the behavior of a system of true hard cylinders has been studied. Values of the length-to-breadth ratio L/D and packing fraction η have been chosen similar to those of real nematic liquid crystals. Results include radial distribution function g(r), structure factor S(k), and orientational order parameter M. These results lead to the conclusion that the hard cylinder model may be a useful reference for real mesomorphic phases.
Analysis of a rate-adaptive reconciliation protocol and the effect of leakage on the secret key rate
Resumo:
Quantum key distribution performs the trick of growing a secret key in two distant places connected by a quantum channel. The main reason is so that the legitimate users can bound the information gathered by the eavesdropper. In practical systems, whether because of finite resources or external conditions, the quantum channel is subject to fluctuations. A rate-adaptive information reconciliation protocol, which adapts to the changes in the communication channel, is then required to minimize the leakage of information in the classical postprocessing. We consider here the leakage of a rate-adaptive information reconciliation protocol. The length of the exchanged messages is larger than that of an optimal protocol; however, we prove that the min-entropy reduction is limited. The simulation results, both in the asymptotic and in the finite-length regime, show that this protocol allows to increase the amount of a distillable secret key.
Resumo:
ABSTRACT Evaluating the reliability, warranty period, and power degradation of high concentration solar cells is crucial to introducing this new technology to the market. The reliability of high concentration GaAs solar cells, as measured in temperature accelerated life tests, is described in this paper. GaAs cells were tested under high thermal accelerated conditions that emulated operation under 700 or 1050 suns over a period exceeding 10 000 h. Progressive power degradation was observed, although no catastrophic failures occurred. An Arrhenius activation energy of 1.02 eV was determined from these tests. The solar cell reliability [R(t)] under working conditions of 65°C was evaluated for different failure limits (1–10% power loss). From this reliability function, the mean time to failure and the warranty time were evaluated. Solar cell temperature appeared to be the primary determinant of reliability and warranty period, with concentration being the secondary determinant. A 30-year warranty for these 1 mm2-sized GaAs cells (manufactured according to a light emitting diode-like approach) may be offered for both cell concentrations (700 and 1050 suns) if the solar cell is operated at a working temperature of 65°C.
Resumo:
We demonstrate the existence of generalized synchronization in systems that act as mediators between two dynamical units that, in turn, show complete synchronization with each other. These are the so-called relay systems. Specifically, we analyze the Lyapunov spectrum of the full system to elucidate when complete and generalized synchronization appear. We show that once a critical coupling strength is achieved, complete synchronization emerges between the systems to be synchronized, and at the same point, generalized synchronization with the relay system also arises. Next, we use two nonlinear measures based on the distance between phase-space neighbors to quantify the generalized synchronization in discretized time series. Finally, we experimentally show the robustness of the phenomenon and of the theoretical tools here proposed to characterize it.
Resumo:
Two experiments were conducted to estimate the standardized ileal digestible (SID) Trp:Lys ratio requirement for growth performance of nursery pigs. Experimental diets were formulated to ensure that lysine was the second limiting AA throughout the experiments. In Exp. 1 (6 to 10 kg BW), 255 nursery pigs (PIC 327 × 1050, initially 6.3 ± 0.15 kg, mean ± SD) arranged in pens of 6 or 7 pigs were blocked by pen weight and assigned to experimental diets (7 pens/diet) consisting of SID Trp:Lys ratios of 14.7%, 16.5%, 18.4%, 20.3%, 22.1%, and 24.0% for 14 d with 1.30% SID Lys. In Exp. 2 (11 to 20 kg BW), 1,088 pigs (PIC 337 × 1050, initially 11.2 kg ± 1.35 BW, mean ± SD) arranged in pens of 24 to 27 pigs were blocked by average pig weight and assigned to experimental diets (6 pens/diet) consisting of SID Trp:Lys ratios of 14.5%, 16.5%, 18.0%, 19.5%, 21.0%, 22.5%, and 24.5% for 21 d with 30% dried distillers grains with solubles and 0.97% SID Lys. Each experiment was analyzed using general linear mixed models with heterogeneous residual variances. Competing heteroskedastic models included broken-line linear (BLL), broken-line quadratic (BLQ), and quadratic polynomial (QP). For each response, the best-fitting model was selected using Bayesian information criterion. In Exp. 1 (6 to 10 kg BW), increasing SID Trp:Lys ratio linearly increased (P < 0.05) ADG and G:F. For ADG, the best-fitting model was a QP in which the maximum ADG was estimated at 23.9% (95% confidence interval [CI]: [<14.7%, >24.0%]) SID Trp:Lys ratio. For G:F, the best-fitting model was a BLL in which the maximum G:F was estimated at 20.4% (95% CI: [14.3%, 26.5%]) SID Trp:Lys. In Exp. 2 (11 to 20 kg BW), increasing SID Trp:Lys ratio increased (P < 0.05) ADG and G:F in a quadratic manner. For ADG, the best-fitting model was a QP in which the maximum ADG was estimated at 21.2% (95% CI: [20.5%, 21.9%]) SID Trp:Lys. For G:F, BLL and BLQ models had comparable fit and estimated SID Trp:Lys requirements at 16.6% (95% CI: [16.0%, 17.3%]) and 17.1% (95% CI: [16.6%, 17.7%]), respectively. In conclusion, the estimated SID Trp:Lys requirement in Exp. 1 ranged from 20.4% for maximum G:F to 23.9% for maximum ADG, whereas in Exp. 2 it ranged from 16.6% for maximum G:F to 21.2% for maximum ADG. These results suggest that standard NRC (2012) recommendations may underestimate the SID Trp:Lys requirement for nursery pigs from 11 to 20 kg BW.