4 resultados para ^3He
em Universidad Politécnica de Madrid
Resumo:
The relativistic distorted-wave impulse approximation is used to describe the 3He(e, e′ p)2H process. We describe the 3He nucleus within the adiabatic hyperspherical expansion method with realistic nucleon-nucleon interactions. The overlap between the 3He and the deuteron wave functions can be accurately computed from a three-body calculation. The nucleons are described by solutions of the Dirac equation with scalar and vector (S–V) potentials. The wave function of the outgoing proton is obtained by solving the Dirac equation with a S–V optical potential fitted to elastic proton scattering data on the residual nucleus. Within this theoretical framework, we compute the cross section of the reaction and other observables like the transverse-longitudinal asymmetry, and compare them with the available experimental data measured at JLab.
Resumo:
Neutron spectra unfolding and dose equivalent calculation are complicated tasks in radiation protection, are highly dependent of the neutron energy, and a precise knowledge on neutron spectrometry is essential for all dosimetry-related studies as well as many nuclear physics experiments. In previous works have been reported neutron spectrometry and dosimetry results, by using the ANN technology as alternative solution, starting from the count rates of a Bonner spheres system with a LiI(Eu) thermal neutrons detector, 7 polyethylene spheres and the UTA4 response matrix with 31 energy bins. In this work, an ANN was designed and optimized by using the RDANN methodology for the Bonner spheres system used at CIEMAT Spain, which is composed of a He neutron detector, 12 moderator spheres and a response matrix for 72 energy bins. For the ANN design process a neutrons spectra catalogue compiled by the IAEA was used. From this compilation, the neutrons spectra were converted from lethargy to energy spectra. Then, the resulting energy ?uence spectra were re-binned by using the MCNP code to the corresponding energy bins of the He response matrix before mentioned. With the response matrix and the re-binned spectra the counts rate of the Bonner spheres system were calculated and the resulting re-binned neutrons spectra and calculated counts rate were used as the ANN training data set.
Resumo:
Se ha estudiado la anisotropía de una fuente de Am-Be de 111 GBq (3Ci) mediante el uso de un pequeño motor que permite girar paso a paso la fuente situada en su posición de irradiación habitual. Las medidas se han realizado con un contador proporcional de 3He alojado en el interior de una esfera moderadora de 8” correspondiente a un sistema de espectrometría de esferas Bonner. Se reportan los resultados obtenidos y el factor de anisotropía determinado para esta fuente.
Resumo:
An automated panoramic irradiator with a 3 Ci 241Am-Be neutron source is installed in a bunker-type large room at the Universidad Politécnica de Madrid (UPM). It was recently modified and a neutron spectrometry campaign was organized to characterize the neutron fields in different measurement points along the irradiation bench. Four research groups working with different Bonner Sphere Spectrometers (BSS) and using different spectral unfolding codes took part to this exercise. INFN-LNF used a BSS formed by 9 spheres plus bare detector, with cylindrical, almost point like, 6LiI(Eu) scintillator (4 mm x 4 mm, from Ludlum); UAZ-UPM employed a similar system but with only 6 spheres plus bare detector; UAB worked with a 3He filled proportional counter at 8kPa filling pressure, cylindrical 9 mm x 10 mm (05NH1 from Eurisys) with 11 spheres configuration; and CIEMAT used 12 spheres with an spherical 3He SP9 counter (Centronic Ltd., UK) with very high sensitivity due to the large diameter (3.2 cm) and the filling pressure of the order of 228 kPa. Each group applied a different spectral unfolding method: INFN and UAB worked with FRUIT ver. 3.0 with their own response matrixes; UAZ-UPM used the BUNKIUT unfolding code with the response matrix UTA4 and CIEMAT employed the GRAVEL-MAXED-IQU package with their own response matrix. The paper shows the main results obtained in terms of neutron spectra at fixed distances from the source as well as total neutron fluence rate and ambient dose equivalent rate H*(10) determined from the spectra. The latter are compared with the readings of a common active survey-meter (LB 6411). The small differences in the results of the various groups are discussed.