77 resultados para Output-only Modal-based Damage Identification


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a time-domain stochastic system identification method based on Maximum Likelihood Estimation and the Expectation Maximization algorithm that is applied to the estimation of modal parameters from system input and output data. The effectiveness of this structural identification method is evaluated through numerical simulation. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the simulated structure are estimated applying the proposed identification method to a set of 100 simulated cases. The numerical results show that the proposed method estimates the modal parameters with precision in the presence of 20% measurement noise even. Finally, advantages and disadvantages of the method have been discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

RESUMEN Su objetivo esencial: Regular el proceso de la edificación, está basado en 3 grandes pilares: 1.- Completar la configuración legal de los agentes que intervienen en el mismo, fijando sus obligaciones para así establecer las responsabilidades. 2.- Fomentar la calidad de los edificios. 3.- Fijar las garantías a los usuarios frente a los posibles daños. Estos tres fundamentos están intensamente relacionados, ya que, las obligaciones y responsabilidades de los agentes son la base de la constitución de las garantías a los usuarios, definidas mediante los requisitos básicos que deben satisfacer los edificios. Partiendo del análisis cualitativo y cuantitativo del grado de cumplimiento del objetivo de la nueva Ley, elaborado a través del estudio de sus tres pilares fundamentales, proponemos medidas tendentes a la plena entrada en vigor de la misma. Para ello se deberá desarrollar el Real Decreto previsto en la Disposición Adicional 2ª, una vez conseguido el grado de madurez de los sectores de la edificación y del seguro. En todo este proceso de estudio hemos podido apreciar que la objetiva identificación de los daños y en especial los que afectan la estabilidad del edificio, constituye una herramienta fundamental para la correcta atribución de responsabilidades a los agentes, basada en la aplicación de los tres grados de responsabilidad “ex lege” por daños materiales y sus plazos de prescripción surgidos del nuevo régimen impuesto por el art. 17 LOE Para avalar esta propuesta hemos analizado: 1.- El entorno económico, general y pormenorizado al sector de la edificación, en Europa y España durante el período comprendido entre los años 1990 y 2013, años previos y posteriores a la entrada en vigor de la Ley, dada la influencia de los ciclos de actividad producidos en la regulación del sector, las responsabilidades atribuidas a los agentes, el fomento de la calidad y las garantías ofrecidas a los adquirentes. 2.- Las diversas legislaciones sobre responsabilidades y garantías de los agentes de la edificación en los países de nuestro entorno económico. 3.- La gestación de la LOE, incidiendo en la evolución de los últimos borradores y su tramitación parlamentaria. 4.- El desarrollo doctrinal de la Transición desde el régimen de responsabilidades, fijado por el art. 1591 de Código Civil, y su Jurisprudencia, hacia el nuevo régimen de responsabilidades establecido por el art. 17 LOE. En esta tarea además de apreciar la asimilación, por parte de los Jueces y Magistrados, de los principios doctrinales de la LOE, hemos observado la labor de los peritos, de cuya experta identificación de las causas de los daños depende la justa y eficaz atribución de responsabilidades. 5 -. El grado de eficacia de la LOE a la vista de la estadística siniestral, de la que ya hay datos consolidados, tras la cancelación de casi 15.000 expedientes de reclamación a Arquitectos. 6 -. También hemos estudiado el grado de cumplimiento con el usuario y propietario de las garantías previstas en el art. 19 de la Ley y en la D.A. 1ª, los efectos reales alcanzados y las tareas pendientes por delante. Analizando la atribución de responsabilidades a los agentes de la edificación, dentro del primer pilar fundamental de la LOE, hemos estudiado las actuaciones de los peritos expertos y su incidencia en este objetivo, previa selección de casos de gran interés y dificultad. Fruto de ello se han formulado propuestas tendentes a la especialización de este colectivo, evitando conductas “irregulares” que tanto daño provocan a los agentes reclamados como a los propietarios afectados. Este daño es evidente pudiendo ocasionar condenas injustas, enriquecimientos ilícitos o bien falsas expectativas de satisfacción de daños mal dictaminados y costosas e ineficaces reparaciones. De cara a la consecución del pilar de la calidad de la edificación, mediante los requisitos básicos planteados por la LOE y desarrollados por el Código Técnico de la Edificación (Real Decreto 314/2006, de 17 de marzo), hemos procesado datos de expedientes de reclamaciones por daños que afectan a edificios ejecutados bajo el nuevo régimen LOE. Con esta base se han analizado las causas generadoras de las diversas lesiones y su frecuencia para que de este análisis puedan establecerse pautas de actuación para su prevención. Finalmente, tras demostrar que las garantías obligatorias impuestas por la LOE sólo abarcan un pequeño porcentaje de los posibles daños a la edificación, insistimos en la necesidad de la plena eficacia de la Ley mediante la aprobación de todas las garantías previstas y para todo tipo de edificaciones. En suma, se ha diseñado la tesis como una matriz abierta en la que podremos continuar incorporando datos de la evolución de la doctrina, la jurisprudencia y la estadística de los daños en la edificación. ABSTRACT The approval of Law 38/1999 on November 5, 1999, (Official Gazette BOE 266/1999 of 11.6.1999, p. 38925), was the culmination of a long period of over 20 years of gestation for which deep agreements were needed between all stakeholders affected. Although several parliamentary groups denounced its incomplete approval, regarding mandatory guarantees to the purchaser, its enactment caused general satisfaction among most of the the building agents. This assessment remains after fourteen years since its partial enactment. Its essential purpose, “to regulate the building process”, is based on 3 pillars: 1.- To complete the legal configuration of the agents involved in it, setting their obligations in order to establish their responsibilities. 2.- To promote the buildings quality. 3.- To specify users´guarantees against possible buildings damage. These three issues are strongly related, since the obligations and responsibilities of the actors are the basis of the users’guarantees constitution, defined by the basic performance required by buildings. Based on the qualitative and quantitative analysis of the fulfillment of the new law’s objectives, made by monitoring the three pillars, we propose measures to the full enactment of this Directive, by the development of the Royal Decree, provided in its Second Additional Provision, once maturity in the sectors of the building and insurance is achieved. Throughout this process of study we have seen that the skill identification of damage, particularly those affecting the stability of the building, is an essential tool for the proper allocation of responsibilities of the new regime installed by the art. 17 LOE, based on the application of the three degrees of responsibility "ex lege" for property damage and limitation periods. To support this proposal, we have analyzed: 1.- The evolution of the building sector in Europe and Spain during the years before and after the enactment of the Law, due to the influence of cycles of activity produced in industry regulation, the responsibilities attributed to agents, promotion of the quality and the assurances given to acquirers. 2.- The scope of various laws on liability and building agents warranties in the countries of our economic environment. 3.- The long period of LOE generation, focusing on the developments in recent drafts and parliamentary procedure. 4.- The doctrinal development in the Transition from the regime of responsibilities, set by art. 1591 of the Civil Code, and its Jurisprudence, to the new liability regime established by art. 17 LOE. In this task, while we have noted assimilation by the Judges and Magistrates of the doctrinal principles of the LOE, we have also analyzed the work of experts, whose skilled identification of the damage causes helps the fair and efficient allocation of responsibilities. 5 - The effectiveness of the LOE based on knowledge of the siniestral statistics, which are already consolidated data, after the cancellation of nearly 15,000 claims to Architects. 6.- We have also studied the degree of compliance with the user and owner guarantees, established in art. 19 and the D.A. 1th of the LOE, exposing the real effects achieved and the pending tasks ahead. Analyzing the allocation of the building agents´ responsibilities, within the first cornerstone of the LOE, we have studied the expert witnesses actions and their impact on this duty, selecting cases of great interest and difficulty in this aim. The result of this enterprise has been to propose the specialization of this group, avoiding "irregular" behaviors that create as much damage as the agents claimed to affected owners. This damage is evident and can cause wrong convictions, illicit enrichment, false expectations and inefficient and costly damage repairs. In order to achieve the pillar of building quality through the basic requirements set by the LOE and developed by the Technical Building Code (Royal Decree 314/ 2006 of 17 March), we have analyzed records of damage claims involving buildings executed under the new regime LOE. On this basis we have analyzed the root causes of various damages and their frequency, from these data it will be easy to propose lines of action for prevention. Finally, after demonstrating that mandatory warranties imposed by LOE cover only a small percentage of the potential building damage, we emphasize the need for the full effectiveness of the Law by the obligation all the guarantees provided in the art. 19 LOE, and for all types of buildings. In conclusion, this thesis is designed as an open matrix in which we will continue including data on the evolution of the doctrine, jurisprudence and the statistics of the damage to the building.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Early and effective identification of developmental disorders during childhood remains a critical task for the international community. The second highest prevalence of common developmental disorders in children are language delays, which are frequently the first symptoms of a possible disorder. Objective: This paper evaluates a Web-based Clinical Decision Support System (CDSS) whose aim is to enhance the screening of language disorders at a nursery school. The common lack of early diagnosis of language disorders led us to deploy an easy-to-use CDSS in order to evaluate its accuracy in early detection of language pathologies. This CDSS can be used by pediatricians to support the screening of language disorders in primary care. Methods: This paper details the evaluation results of the ?Gades? CDSS at a nursery school with 146 children, 12 educators, and 1 language therapist. The methodology embraces two consecutive phases. The first stage involves the observation of each child?s language abilities, carried out by the educators, to facilitate the evaluation of language acquisition level performed by a language therapist. Next, the same language therapist evaluates the reliability of the observed results. Results: The Gades CDSS was integrated to provide the language therapist with the required clinical information. The validation process showed a global 83.6% (122/146) success rate in language evaluation and a 7% (7/94) rate of non-accepted system decisions within the range of children from 0 to 3 years old. The system helped language therapists to identify new children with potential disorders who required further evaluation. This process will revalidate the CDSS output and allow the enhancement of early detection of language disorders in children. The system does need minor refinement, since the therapists disagreed with some questions from the CDSS knowledge base (KB) and suggested adding a few questions about speech production and pragmatic abilities. The refinement of the KB will address these issues and include the requested improvements, with the support of the experts who took part in the original KB development. Conclusions: This research demonstrated the benefit of a Web-based CDSS to monitor children?s neurodevelopment via the early detection of language delays at a nursery school. Current next steps focus on the design of a model that includes pseudo auto-learning capacity, supervised by experts.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent advances in non-destructive imaging techniques, such as X-ray computed tomography (CT), make it possible to analyse pore space features from the direct visualisation from soil structures. A quantitative characterisation of the three-dimensional solid-pore architecture is important to understand soil mechanics, as they relate to the control of biological, chemical, and physical processes across scales. This analysis technique therefore offers an opportunity to better interpret soil strata, as new and relevant information can be obtained. In this work, we propose an approach to automatically identify the pore structure of a set of 200-2D images that represent slices of an original 3D CT image of a soil sample, which can be accomplished through non-linear enhancement of the pixel grey levels and an image segmentation based on a PFCM (Possibilistic Fuzzy C-Means) algorithm. Once the solids and pore spaces have been identified, the set of 200-2D images is then used to reconstruct an approximation of the soil sample by projecting only the pore spaces. This reconstruction shows the structure of the soil and its pores, which become more bounded, less bounded, or unbounded with changes in depth. If the soil sample image quality is sufficiently favourable in terms of contrast, noise and sharpness, the pore identification is less complicated, and the PFCM clustering algorithm can be used without additional processing; otherwise, images require pre-processing before using this algorithm. Promising results were obtained with four soil samples, the first of which was used to show the algorithm validity and the additional three were used to demonstrate the robustness of our proposal. The methodology we present here can better detect the solid soil and pore spaces on CT images, enabling the generation of better 2D?3D representations of pore structures from segmented 2D images.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The city of Lorca (Spain) was hit on May 11th, 2011, by two consecutive earth-quakes of magnitudes 4.6 and 5.2 Mw, causing casualties and important damage in buildings. Many of the damaged structures were reinforced concrete frames with wide beams. This study quantifies the expected level of damage on this structural type in the case of the Lorca earth-quake by means of a seismic index Iv that compares the energy input by the earthquake with the energy absorption/dissipation capacity of the structure. The prototype frames investigated represent structures designed in two time periods (1994–2002 and 2003–2008), in which the applicable codes were different. The influence of the masonry infill walls and the proneness of the frames to concentrate damage in a given story were further investigated through nonlinear dynamic response analyses. It is found that (1) the seismic index method predicts levels of damage that range from moderate/severe to complete collapse; this prediction is consistent with the observed damage; (2) the presence of masonry infill walls makes the structure very prone to damage concentration and reduces the overall seismic capacity of the building; and (3) a proper hierarchy of strength between beams and columns that guarantees the formation of a strong column-weak beam mechanism (as prescribed by seismic codes), as well as the adoption of counter-measures to avoid the negative interaction between non-structural infill walls and the main frame, would have reduced the level of damage from Iv=1 (collapse) to about Iv=0.5 (moderate/severe damage)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance-based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column-weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake-table tests were conducted on a 2/5-scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of "immediate occupancy", with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Análisis de precisión en modelos digitales de elevación globales. ABSTRACT: Terrain-Based Analysis results in derived products from an input DEM and these products are needed to perform various analyses. To efficiently use these products in decision-making, their accuracies must be estimated systematically. This paper proposes a procedure to assess the accuracy of these derived products, by calculating the accuracy of the slope dataset and its significance, taking as an input the accuracy of the DEM. Based on the output of previously published research on modeling the relative accuracy of a DEM, specifically ASTER and SRTM DEMs with Lebanon coverage as the area of study, analysis have showed that ASTER has a low significance in the majority of the area where only 2% of the modeled terrain has 50% or more significance. On the other hand, SRTM showed a better significance, where 37% of the modeled terrain has 50% or more significance. Statistical analysis deduced that the accuracy of the slope dataset, calculated on a cell-by-cell basis, is highly correlated to the accuracy of the input DEM. However, this correlation becomes lower between the slope accuracy and the slope significance, whereas it becomes much higher between the modeled slope and the slope significance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of the Electro-Mechanical Impedance (EMI) method for damage detection in Structural Health Monitoring has noticeable increased in recent years. EMI method utilizes piezoelectric transducers for directly measuring the mechanical properties of the host structure, obtaining the so called impedance measurement, highly influenced by the variations of dynamic parameters of the structure. These measurements usually contain a large number of frequency points, as well as a high number of dimensions, since each frequency range swept can be considered as an independent variable. That makes this kind of data hard to handle, increasing the computational costs and being substantially time-consuming. In that sense, the Principal Component Analysis (PCA)-based data compression has been employed in this work, in order to enhance the analysis capability of the raw data. Furthermore, a Support Vector Machine (SVM), which has been widespread used in machine learning and pattern recognition fields, has been applied in this study in order to model any possible existing pattern in the PCAcompress data, using for that just the first two Principal Components. Different known non-damaged and damaged measurements of an experimental tested beam were used as training input data for the SVM algorithm, using as test input data the same amount of cases measured in beams with unknown structural health conditions. Thus, the purpose of this work is to demonstrate how, with a few impedance measurements of a beam as raw data, its healthy status can be determined based on pattern recognition procedures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Material properties of soft tissues are highly conditioned by the hierarchical structure of this kind of composites. These collagen-based tissues present a complex framework of fibres, fibrils, tropocollagen molecules and amino-acids. As the structural mechanisms that control the degradation of soft tissues are related with the behaviour of its fundamental constituents, the relationship between the molecular and intermolecular properties and the tissue behaviour needs to be studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El objetivo principal de esta tesis ha sido el diseño y la optimización de receptores implementados con fibra óptica, para ser usados en redes ópticas de alta velocidad que empleen formatos de modulación de fase. En los últimos años, los formatos de modulación de fase (Phase Shift keying, PSK) han captado gran atención debido a la mejora de sus prestaciones respecto a los formatos de modulación convencionales. Principalmente, presentan una mejora de la eficiencia espectral y una mayor tolerancia a la degradación de la señal causada por la dispersión cromática, la dispersión por modo de polarización y los efectos no-lineales en la fibra óptica. En este trabajo, se analizan en detalle los formatos PSK, incluyendo sus variantes de modulación de fase diferencial (Differential Phase Shift Keying, DPSK), en cuadratura (Differential Quadrature Phase Shift Keying, DQPSK) y multiplexación en polarización (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), con la finalidad de diseñar y optimizar los receptores que permita su demodulación. Para ello, se han analizado y desarrollado nuevas estructuras que ofrecen una mejora en las prestaciones del receptor y una reducción de coste comparadas con las actualmente disponibles. Para la demodulación de señales DPSK, en esta tesis, se proponen dos nuevos receptores basados en un interferómetro en línea Mach-Zehnder (MZI) implementado con tecnología todo-fibra. El principio de funcionamiento de los MZI todo-fibra propuestos se asienta en la interferencia modal que se produce en una fibra multimodo (MMF) cuando se situada entre dos monomodo (SMF). Este tipo de configuración (monomodo-multimodo-monomodo, SMS) presenta un buen ratio de extinción interferente si la potencia acoplada en la fibra multimodo se reparte, principal y equitativamente, entre dos modos dominantes. Con este objetivo, se han estudiado y demostrado tanto teórica como experimentalmente dos nuevas estructuras SMS que mejoran el ratio de extinción. Una de las propuestas se basa en emplear una fibra multimodo de índice gradual cuyo perfil del índice de refracción presenta un hundimiento en su zona central. La otra consiste en una estructura SMS con las fibras desalineadas y donde la fibra multimodo es una fibra de índice gradual convencional. Para las dos estructuras, mediante el análisis teórico desarrollado, se ha demostrado que el 80 – 90% de la potencia de entrada se acopla a los dos modos dominantes de la fibra multimodo y se consigue una diferencia inferior al 10% entre ellos. También se ha demostrado experimentalmente que se puede obtener un ratio de extinción de al menos 12 dB. Con el objeto de demostrar la capacidad de estas estructuras para ser empleadas como demoduladores de señales DPSK, se han realizado numerosas simulaciones de un sistema de transmisión óptico completo y se ha analizado la calidad del receptor bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo o la tolerancia a las dispersiones cromática y por modo de polarización. En todos los casos se ha concluido que los receptores propuestos presentan rendimientos comparables a los obtenidos con receptores convencionales. En esta tesis, también se presenta un diseño alternativo para la implementación de un receptor DQPSK, basado en el uso de una fibra mantenedora de la polarización (PMF). A través del análisi teórico y del desarrollo de simulaciones numéricas, se ha demostrado que el receptor DQPSK propuesto presenta prestaciones similares a los convencionales. Para complementar el trabajo realizado sobre el receptor DQPSK basado en PMF, se ha extendido el estudio de su principio de demodulación con el objeto de demodular señales PM-DQPSK, obteniendo como resultado la propuesta de una nueva estructura de demodulación. El receptor PM-DQPSK propuesto se basa en la estructura conjunta de una única línea de retardo junto con un rotador de polarización. Se ha analizado la calidad de los receptores DQPSK y PM-DQPSK bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo, la tolerancia a las dispersiones cromática y por modo de polarización o su comportamiento bajo condiciones no-ideales. En comparación con los receptores convencionales, nuestra propuesta exhibe prestaciones similares y además permite un diseño más simple que redunda en un coste potencialmente menor. En las redes de comunicaciones ópticas actuales se utiliza la tecnología de multimplexación en longitud de onda (WDM) que obliga al uso de filtros ópticos con bandas de paso lo más estrechas posibles y a emplear una serie de dispositivos que incorporan filtros en su arquitectura, tales como los multiplexores, demultiplexores, ROADMs, conmutadores y OXCs. Todos estos dispositivos conectados entre sí son equivalentes a una cadena de filtros cuyo ancho de banda se va haciendo cada vez más estrecho, llegando a distorsionar la forma de onda de las señales. Por esto, además de analizar el impacto del filtrado óptico en las señales de 40 Gbps DQPSK y 100 Gbps PM-DQPSK, este trabajo de tesis se completa estudiando qué tipo de filtro óptico minimiza las degradaciones causadas en la señal y analizando el número máximo de filtros concatenados que permiten mantener la calidad requerida al sistema. Se han estudiado y simulado cuatro tipos de filtros ópticos;Butterworth, Bessel, FBG y F-P. ABSTRACT The objective of this thesis is the design and optimization of optical fiber-based phase shift keying (PSK) demodulators for high-bit-rate optical networks. PSK modulation formats have attracted significant attention in recent years, because of the better performance with respect to conventional modulation formats. Principally, PSK signals can improve spectrum efficiency and tolerate more signal degradation caused by chromatic dispersion, polarization mode dispersion and nonlinearities in the fiber. In this work, many PSK formats were analyzed in detail, including the variants of differential phase modulation (Differential Phase Shift Keying, DPSK), in quadrature (Differential Quadrature Phase Shift Keying, DQPSK) and polarization multiplexing (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), in order to design and optimize receivers enabling demodulations. Therefore, novel structures, which offer good receiver performances and a reduction in cost compared to the current structures, have been analyzed and developed. Two novel receivers based on an all-fiber in-line Mach-Zehnder interferometer (MZI) were proposed for DPSK signal demodulation in this thesis. The operating principle of the all-fiber MZI is based on the modal interference that occurs in a multimode fiber (MMF) when it is located between two single-mode fibers (SMFs). This type of configuration (Single-mode-multimode-single-mode, SMS) can provide a good extinction ratio if the incoming power from the SMF could be coupled equally into two dominant modes excited in the MMF. In order to improve the interference extinction ratio, two novel SMS structures have been studied and demonstrated, theoretically and experimentally. One of the two proposed MZIs is based on a graded-index multimode fiber (MMF) with a central dip in the index profile, located between two single-mode fibers (SMFs). The other one is based on a conventional graded-index MMF mismatch spliced between two SMFs. Theoretical analysis has shown that, in these two schemes, 80 – 90% of the incoming power can be coupled into the two dominant modes exited in the MMF, and the power difference between them is only ~10%. Experimental results show that interference extinction ratio of 12 dB could be obtained. In order to demonstrate the capacity of these two structures for use as DPSK signal demodulators, numerical simulations in a completed optical transmission system have been carried out, and the receiver quality has been analyzed under different perspectives, such as sensitivity, tolerance to severe optical filtering or tolerance to chromatic and polarization mode dispersion. In all cases, from the simulation results we can conclude that the two proposed receivers can provide performances comparable to conventional ones. In this thesis, an alternative design for the implementation of a DQPSK receiver, which is based on a polarization maintaining fiber (PMF), was also presented. To complement the work made for the PMF-based DQPSK receiver, the study of the demodulation principle has been extended to demodulate PM-DQPSK signals, resulting in the proposal of a novel demodulation structure. The proposed PM-DQPSK receiver is based on only one delay line and a polarization rotator. The quality of the proposed DQPSK and PM-DQPSK receivers under different perspectives, such as sensitivity, tolerance to severe optical filtering, tolerance to chromatic dispersion and polarization mode dispersion, or behavior under non-ideal conditions. Compared with the conventional receivers, our proposals exhibit similar performances but allow a simpler design which can potentially reduce the cost. The wavelength division multiplexing (WDM) technology used in current optical communications networks requires the use of optical filters with a passband as narrow as possible, and the use of a series of devices that incorporate filters in their architecture, such as multiplexers, demultiplexers, switches, reconfigurable add-drop multiplexers (ROADMs) and optical cross-connects (OXCs). All these devices connected together are equivalent to a chain of filters whose bandwidth becomes increasingly narrow, resulting in distortion to the waveform of the signals. Therefore, in addition to analyzing the impact of optical filtering on signal of 40 Gbps DQPSK and 100 Gbps PM-DQPSK, we study which kind of optical filter minimizes the signal degradation and analyze the maximum number of concatenated filters for maintaining the required quality of the system. Four types of optical filters, including Butterworth, Bessel, FBG and FP, have studied and simulated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Query rewriting is one of the fundamental steps in ontologybased data access (OBDA) approaches. It takes as inputs an ontology and a query written according to that ontology, and produces as an output a set of queries that should be evaluated to account for the inferences that should be considered for that query and ontology. Different query rewriting systems give support to different ontology languages with varying expressiveness, and the rewritten queries obtained as an output do also vary in expressiveness. This heterogeneity has traditionally made it difficult to compare different approaches, and the area lacks in general commonly agreed benchmarks that could be used not only for such comparisons but also for improving OBDA support. In this paper we compile data, dimensions and measurements that have been used to evaluate some of the most recent systems, we analyse and characterise these assets, and provide a unified set of them that could be used as a starting point towards a more systematic benchmarking process for such systems. Finally, we apply this initial benchmark with some of the most relevant OBDA approaches in the state of the art.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El desarrollo da las nuevas tecnologías permite a los ingenieros llevar al límite el funcionamiento de los circuitos integrados (Integrated Circuits, IC). Las nuevas generaciones de procesadores, DSPs o FPGAs son capaces de procesar la información a una alta velocidad, con un alto consumo de energía, o esperar en modo de baja potencia con el mínimo consumo posible. Esta gran variación en el consumo de potencia y el corto tiempo necesario para cambiar de un nivel al otro, afecta a las especificaciones del Módulo de Regulador de Tensión (Voltage Regulated Module, VRM) que alimenta al IC. Además, las características adicionales obligatorias, tales como adaptación del nivel de tensión (Adaptive Voltage Positioning, AVP) y escalado dinámico de la tensión (Dynamic Voltage Scaling, DVS), imponen requisitos opuestas en el diseño de la etapa de potencia del VRM. Para poder soportar las altas variaciones de los escalones de carga, el condensador de filtro de salida del VRM se ha de sobredimensionar, penalizando la densidad de energía y el rendimiento durante la operación de DVS. Por tanto, las actuales tendencias de investigación se centran en mejorar la respuesta dinámica del VRM, mientras se reduce el tamaño del condensador de salida. La reducción del condensador de salida lleva a menor coste y una prolongación de la vida del sistema ya que se podría evitar el uso de condensadores voluminosos, normalmente implementados con condensadores OSCON. Una ventaja adicional es que reduciendo el condensador de salida, el DVS se puede realizar más rápido y con menor estrés de la etapa de potencia, ya que la cantidad de carga necesaria para cambiar la tensión de salida es menor. El comportamiento dinámico del sistema con un control lineal (Control Modo Tensión, VMC, o Control Corriente de Pico, Peak Current Mode Control, PCMC,…) está limitado por la frecuencia de conmutación del convertidor y por el tamaño del filtro de salida. La reducción del condensador de salida se puede lograr incrementando la frecuencia de conmutación, así como incrementando el ancho de banda del sistema, y/o aplicando controles avanzados no-lineales. Usando esos controles, las variables del estado se saturan para conseguir el nuevo régimen permanente en un tiempo mínimo, así como el filtro de salida, más específicamente la pendiente de la corriente de la bobina, define la respuesta de la tensión de salida. Por tanto, reduciendo la inductancia de la bobina de salida, la corriente de bobina llega más rápido al nuevo régimen permanente, por lo que una menor cantidad de carga es tomada del condensador de salida durante el tránsito. El inconveniente de esa propuesta es que el rendimiento del sistema es penalizado debido al incremento de pérdidas de conmutación y las corrientes RMS. Para conseguir tanto la reducción del condensador de salida como el alto rendimiento del sistema, mientras se satisfacen las estrictas especificaciones dinámicas, un convertidor multifase es adoptado como estándar para aplicaciones VRM. Para asegurar el reparto de las corrientes entre fases, el convertidor multifase se suele implementar con control de modo de corriente. Para superar la limitación impuesta por el filtro de salida, la segunda posibilidad para reducir el condensador de salida es aplicar alguna modificación topológica (Topologic modifications) de la etapa básica de potencia para incrementar la pendiente de la corriente de bobina y así reducir la duración de tránsito. Como el transitorio se ha reducido, una menor cantidad de carga es tomada del condensador de salida bajo el mismo escalón de la corriente de salida, con lo cual, el condensador de salida se puede reducir para lograr la misma desviación de la tensión de salida. La tercera posibilidad para reducir el condensador de salida del convertidor es introducir un camino auxiliar de energía (additional energy path, AEP) para compensar el desequilibrio de la carga del condensador de salida reduciendo consecuentemente la duración del transitorio y la desviación de la tensión de salida. De esta manera, durante el régimen permanente, el sistema tiene un alto rendimiento debido a que el convertidor principal con bajo ancho de banda es diseñado para trabajar con una frecuencia de conmutación moderada para conseguir requisitos estáticos. Por otro lado, el comportamiento dinámico durante los transitorios es determinado por el AEP con un alto ancho de banda. El AEP puede ser implementado como un camino resistivo, como regulador lineal (Linear regulator, LR) o como un convertidor conmutado. Las dos primeras implementaciones proveen un mayor ancho de banda, acosta del incremento de pérdidas durante el transitorio. Por otro lado, la implementación del convertidor computado presenta menor ancho de banda, limitado por la frecuencia de conmutación, aunque produce menores pérdidas comparado con las dos anteriores implementaciones. Dependiendo de la aplicación, la implementación y la estrategia de control del sistema, hay una variedad de soluciones propuestas en el Estado del Arte (State-of-the-Art, SoA), teniendo diferentes propiedades donde una solución ofrece más ventajas que las otras, pero también unas desventajas. En general, un sistema con AEP ideal debería tener las siguientes propiedades: 1. El impacto del AEP a las pérdidas del sistema debería ser mínimo. A lo largo de la operación, el AEP genera pérdidas adicionales, con lo cual, en el caso ideal, el AEP debería trabajar por un pequeño intervalo de tiempo, solo durante los tránsitos; la otra opción es tener el AEP constantemente activo pero, por la compensación del rizado de la corriente de bobina, se generan pérdidas innecesarias. 2. El AEP debería ser activado inmediatamente para minimizar la desviación de la tensión de salida. Para conseguir una activación casi instantánea, el sistema puede ser informado por la carga antes del escalón o el sistema puede observar la corriente del condensador de salida, debido a que es la primera variable del estado que actúa a la perturbación de la corriente de salida. De esa manera, el AEP es activado con casi cero error de la tensión de salida, logrando una menor desviación de la tensión de salida. 3. El AEP debería ser desactivado una vez que el nuevo régimen permanente es detectado para evitar los transitorios adicionales de establecimiento. La mayoría de las soluciones de SoA estiman la duración del transitorio, que puede provocar un transitorio adicional si la estimación no se ha hecho correctamente (por ejemplo, si la corriente de bobina del convertidor principal tiene un nivel superior o inferior al necesitado, el regulador lento del convertidor principal tiene que compensar esa diferencia una vez que el AEP es desactivado). Otras soluciones de SoA observan las variables de estado, asegurando que el sistema llegue al nuevo régimen permanente, o pueden ser informadas por la carga. 4. Durante el transitorio, como mínimo un subsistema, o bien el convertidor principal o el AEP, debería operar en el lazo cerrado. Implementando un sistema en el lazo cerrado, preferiblemente el subsistema AEP por su ancho de banda elevado, se incrementa la robustez del sistema a los parásitos. Además, el AEP puede operar con cualquier tipo de corriente de carga. Las soluciones que funcionan en el lazo abierto suelen preformar el control de balance de carga con mínimo tiempo, así reducen la duración del transitorio y tienen un impacto menor a las pérdidas del sistema. Por otro lado, esas soluciones demuestran una alta sensibilidad a las tolerancias y parásitos de los componentes. 5. El AEP debería inyectar la corriente a la salida en una manera controlada, así se reduce el riesgo de unas corrientes elevadas y potencialmente peligrosas y se incrementa la robustez del sistema bajo las perturbaciones de la tensión de entrada. Ese problema suele ser relacionado con los sistemas donde el AEP es implementado como un convertidor auxiliar. El convertidor auxiliar es diseñado para una potencia baja, con lo cual, los dispositivos elegidos son de baja corriente/potencia. Si la corriente no es controlada, bajo un pico de tensión de entrada provocada por otro parte del sistema (por ejemplo, otro convertidor conectado al mismo bus), se puede llegar a un pico en la corriente auxiliar que puede causar la perturbación de tensión de salida e incluso el fallo de los dispositivos del convertidor auxiliar. Sin embargo, cuando la corriente es controlada, usando control del pico de corriente o control con histéresis, la corriente auxiliar tiene el control con prealimentación (feed-forward) de tensión de entrada y la corriente es definida y limitada. Por otro lado, si la solución utiliza el control de balance de carga, el sistema puede actuar de forma deficiente si la tensión de entrada tiene un valor diferente del nominal, provocando que el AEP inyecta/toma más/menos carga que necesitada. 6. Escalabilidad del sistema a convertidores multifase. Como ya ha sido comentado anteriormente, para las aplicaciones VRM por la corriente de carga elevada, el convertidor principal suele ser implementado como multifase para distribuir las perdidas entre las fases y bajar el estrés térmico de los dispositivos. Para asegurar el reparto de las corrientes, normalmente un control de modo corriente es usado. Las soluciones de SoA que usan VMC son limitadas a la implementación con solo una fase. Esta tesis propone un nuevo método de control del flujo de energía por el AEP y el convertidor principal. El concepto propuesto se basa en la inyección controlada de la corriente auxiliar al nodo de salida donde la amplitud de la corriente es n-1 veces mayor que la corriente del condensador de salida con las direcciones apropiadas. De esta manera, el AEP genera un condensador virtual cuya capacidad es n veces mayor que el condensador físico y reduce la impedancia de salida. Como el concepto propuesto reduce la impedancia de salida usando el AEP, el concepto es llamado Output Impedance Correction Circuit (OICC) concept. El concepto se desarrolla para un convertidor tipo reductor síncrono multifase con control modo de corriente CMC (incluyendo e implementación con una fase) y puede operar con la tensión de salida constante o con AVP. Además, el concepto es extendido a un convertidor de una fase con control modo de tensión VMC. Durante la operación, el control de tensión de salida de convertidor principal y control de corriente del subsistema OICC están siempre cerrados, incrementando la robustez a las tolerancias de componentes y a los parásitos del cirquito y permitiendo que el sistema se pueda enfrentar a cualquier tipo de la corriente de carga. Según el método de control propuesto, el sistema se puede encontrar en dos estados: durante el régimen permanente, el sistema se encuentra en el estado Idle y el subsistema OICC esta desactivado. Por otro lado, durante el transitorio, el sistema se encuentra en estado Activo y el subsistema OICC está activado para reducir la impedancia de salida. El cambio entre los estados se hace de forma autónoma: el sistema entra en el estado Activo observando la corriente de condensador de salida y vuelve al estado Idle cunado el nuevo régimen permanente es detectado, observando las variables del estado. La validación del concepto OICC es hecha aplicándolo a un convertidor tipo reductor síncrono con dos fases y de 30W cuyo condensador de salida tiene capacidad de 140μF, mientras el factor de multiplicación n es 15, generando en el estado Activo el condensador virtual de 2.1mF. El subsistema OICC es implementado como un convertidor tipo reductor síncrono con PCMC. Comparando el funcionamiento del convertidor con y sin el OICC, los resultados demuestran que se ha logrado una reducción de la desviación de tensión de salida con factor 12, tanto con funcionamiento básico como con funcionamiento AVP. Además, los resultados son comparados con un prototipo de referencia que tiene la misma etapa de potencia y un condensador de salida físico de 2.1mF. Los resultados demuestran que los dos sistemas tienen el mismo comportamiento dinámico. Más aun, se ha cuantificado el impacto en las pérdidas del sistema operando bajo una corriente de carga pulsante y bajo DVS. Se demuestra que el sistema con OICC mejora el rendimiento del sistema, considerando las pérdidas cuando el sistema trabaja con la carga pulsante y con DVS. Por lo último, el condensador de salida de sistema con OICC es mucho más pequeño que el condensador de salida del convertidor de referencia, con lo cual, por usar el concepto OICC, la densidad de energía se incrementa. En resumen, las contribuciones principales de la tesis son: • El concepto propuesto de Output Impedance Correction Circuit (OICC), • El control a nivel de sistema basado en el método usado para cambiar los estados de operación, • La implementación del subsistema OICC en lazo cerrado conjunto con la implementación del convertidor principal, • La cuantificación de las perdidas dinámicas bajo la carga pulsante y bajo la operación DVS, y • La robustez del sistema bajo la variación del condensador de salida y bajo los escalones de carga consecutiva. ABSTRACT Development of new technologies allows engineers to push the performance of the integrated circuits to its limits. New generations of processors, DSPs or FPGAs are able to process information with high speed and high consumption or to wait in low power mode with minimum possible consumption. This huge variation in power consumption and the short time needed to change from one level to another, affect the specifications of the Voltage Regulated Module (VRM) that supplies the IC. Furthermore, additional mandatory features, such as Adaptive Voltage Positioning (AVP) and Dynamic Voltage Scaling (DVS), impose opposite trends on the design of the VRM power stage. In order to cope with high load-step amplitudes, the output capacitor of the VRM power stage output filter is drastically oversized, penalizing power density and the efficiency during the DVS operation. Therefore, the ongoing research trend is directed to improve the dynamic response of the VRM while reducing the size of the output capacitor. The output capacitor reduction leads to a smaller cost and longer life-time of the system since the big bulk capacitors, usually implemented with OSCON capacitors, may not be needed to achieve the desired dynamic behavior. An additional advantage is that, by reducing the output capacitance, dynamic voltage scaling (DVS) can be performed faster and with smaller stress on the power stage, since the needed amount of charge to change the output voltage is smaller. The dynamic behavior of the system with a linear control (Voltage mode control, VMC, Peak Current Mode Control, PCMC,…) is limited by the converter switching frequency and filter size. The reduction of the output capacitor can be achieved by increasing the switching frequency of the converter, thus increasing the bandwidth of the system, and/or by applying advanced non-linear controls. Applying nonlinear control, the system variables get saturated in order to reach the new steady-state in a minimum time, thus the output filter, more specifically the output inductor current slew-rate, determines the output voltage response. Therefore, by reducing the output inductor value, the inductor current reaches faster the new steady state, so a smaller amount of charge is taken from the output capacitor during the transient. The drawback of this approach is that the system efficiency is penalized due to increased switching losses and RMS currents. In order to achieve both the output capacitor reduction and high system efficiency, while satisfying strict dynamic specifications, a Multiphase converter system is adopted as a standard for VRM applications. In order to ensure the current sharing among the phases, the multiphase converter is usually implemented with current mode control. In order to overcome the limitation imposed by the output filter, the second possibility to reduce the output capacitor is to apply Topologic modifications of the basic power stage topology in order to increase the slew-rate of the inductor current and, therefore, reduce the transient duration. Since the transient is reduced, smaller amount of charge is taken from the output capacitor under the same load current, thus, the output capacitor can be reduced to achieve the same output voltage deviation. The third possibility to reduce the output capacitor of the converter is to introduce an additional energy path (AEP) to compensate the charge unbalance of the output capacitor, consequently reducing the transient time and output voltage deviation. Doing so, during the steady-state operation the system has high efficiency because the main low-bandwidth converter is designed to operate at moderate switching frequency, to meet the static requirements, whereas the dynamic behavior during the transients is determined by the high-bandwidth auxiliary energy path. The auxiliary energy path can be implemented as a resistive path, as a Linear regulator, LR, or as a switching converter. The first two implementations provide higher bandwidth, at the expense of increasing losses during the transient. On the other hand, the switching converter implementation presents lower bandwidth, limited by the auxiliary converter switching frequency, though it produces smaller losses compared to the two previous implementations. Depending on the application, the implementation and the control strategy of the system, there is a variety of proposed solutions in the State-of-the-Art (SoA), having different features where one solution offers some advantages over the others, but also some disadvantages. In general, an ideal additional energy path system should have the following features: 1. The impact on the system losses should be minimal. During its operation, the AEP generates additional losses, thus ideally, the AEP should operate for a short period of time, only when the transient is occurring; the other option is to have the AEP constantly on, but due to the inductor current ripple compensation at the output, unnecessary losses are generated. 2. The AEP should be activated nearly instantaneously to prevent bigger output voltage deviation. To achieve near instantaneous activation, the converter system can be informed by the load prior to the load-step or the system can observe the output capacitor current, which is the first system state variable that reacts on the load current perturbation. In this manner, the AEP is turned on with near zero output voltage error, providing smaller output voltage deviation. 3. The AEP should be deactivated once the new steady state is reached to avoid additional settling transients. Most of the SoA solutions estimate duration of the transient which may cause additional transient if the estimation is not performed correctly (e.g. if the main converter inductor current has higher or lower value than needed, the slow regulator of the main converter needs to compensate the difference after the AEP is deactivated). Other SoA solutions are observing state variables, ensuring that the system reaches the new steady state or they are informed by the load. 4. During the transient, at least one subsystem, either the main converter or the AEP, should be in closed-loop. Implementing a closed loop system, preferably the AEP subsystem, due its higher bandwidth, increases the robustness under system tolerances and circuit parasitic. In addition, the AEP can operate with any type of load. The solutions that operate in open loop usually perform minimum time charge balance control, thus reducing the transient length and minimizing the impact on the losses, however they are very sensitive to tolerances and parasitics. 5. The AEP should inject current at the output in a controlled manner, thus reducing the risk of high and potentially damaging currents and increasing robustness on the input voltage deviation. This issue is mainly related to the systems where AEP is implemented as auxiliary converter. The auxiliary converter is designed for small power and, as such, the MOSFETs are rated for small power/currents. If the current is not controlled, due to the some unpredicted spike in input voltage caused by some other part of the system (e.g. different converter), it may lead to a current spike in auxiliary current which will cause the perturbation of the output voltage and even failure of the switching components of auxiliary converter. In the case when the current is controlled, using peak CMC or Hysteretic Window CMC, the auxiliary converter has inherent feed-forwarding of the input voltage in current control and the current is defined and limited. Furthermore, if the solution employs charge balance control, the system may perform poorly if the input voltage has different value than the nominal, causing that AEP injects/extracts more/less charge than needed. 6. Scalability of the system to multiphase converters. As commented previously, in VRM applications, due to the high load currents, the main converters are implemented as multiphase to redistribute losses among the modules, lowering temperature stress of the components. To ensure the current sharing, usually a Current Mode Control (CMC) is employed. The SoA solutions that are implemented with VMC are limited to a single stage implementation. This thesis proposes a novel control method of the energy flow through the AEP and the main converter system. The proposed concept relays on a controlled injection of the auxiliary current at the output node where the instantaneous current value is n-1 times bigger than the output capacitor current with appropriate directions. Doing so, the AEP creates an equivalent n times bigger virtual capacitor at the output, thus reducing the output impedance. Due to the fact that the proposed concept reduces the output impedance using the AEP, it has been named the Output Impedance Correction Circuit (OICC) concept. The concept is developed for a multiphase CMC synchronous buck converter (including a single phase implementation), operating with a constant output voltage and with AVP feature. Further, it is extended to a single phase VMC synchronous buck converter. During the operation, the main converter voltage loop and the OICC subsystem capacitor current loop is constantly closed, increasing the robustness under system tolerances and circuit parasitic and allowing the system to operate with any load-current shape or pattern. According to the proposed control method, the system operates in two states: during the steady-state the system is in the Idle state and the OICC subsystem is deactivated, while during the load-step transient the system is in the Active state and the OICC subsystem is activated in order to reduce the output impedance. The state changes are performed autonomously: the system enters in the Active state by observing the output capacitor current and it returns back to the Idle state when the steady-state operation is detected by observing the state variables. The validation of the OICC concept has been done by applying it to a 30W two phase synchronous buck converter with 140μF output capacitor and with the multiplication factor n equal to 15, generating during the Active state equivalent output capacitor of 2.1mF. The OICC subsystem is implemented as single phase PCMC synchronous buck converter. Comparing the converter operation with and without the OICC the results demonstrate that the 12 times reduction of the output voltage deviation is achieved, for both basic operation and for the AVP operation. Furthermore, the results have been compared to a reference prototype which has the same power stage and a fiscal output capacitor of 2.1mF. The results show that the two systems have the same dynamic behavior. Moreover, an impact on the system losses under the pulsating load and DVS operation has been quantified and it has been demonstrated that the OICC system has improved the system efficiency, considering the losses when the system operates with the pulsating load and the DVS operation. Lastly, the output capacitor of the OICC system is much smaller than the reference design output capacitor, therefore, by applying the OICC concept the power density can be increased. In summary, the main contributions of the thesis are: • The proposed Output Impedance Correction Circuit (OICC) concept, • The system level control based on the used approach to change the states of operation, • The OICC subsystem closed-loop implementation, together with the main converter implementation, • The dynamic losses under the pulsating load and the DVS operation quantification, and • The system robustness on the capacitor impedance variation and consecutive load-steps.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El diagnóstico y detección temprana de enfermedades son clave para reducir la tasa de mortalidad, las hospitalizaciones de larga duración y el desaprovechamiento de recursos. En los últimos años se ha impulsado, mediante un aumento de la financiación, el desarrollo de nuevos biosensores de bajo coste capaces de detectar y cuantificar cantidades muy pequeñas de especies biológicas de una forma barata y sencilla. El trabajo presentado en esta Tesis Doctoral describe la investigación llevada a cabo en el desarrollo de sensores gravimétricos basados en resonadores de ondas acústicas de volumen (BAW) de estructura maciza (SMR). Los dispositivos emplean películas delgadas de A1N como material piezoeléctrico y operan en modo de cizalladura, para así poder detectar especies biológicas en medio líquido. El principio de funcionamiento de estos sensores se basa en la variación que experimenta la frecuencia de resonancia al quedar una pequeña masa adherida a su superficie. Necesitan operar en modo de cizalladura para que su resonancia no se atenúe al trabajar en medio líquido, así como ofrecer una superficie capaz de ser funcionalizada específicamente para la especie biológica a detectar. El reto planteado en esta tesis requiere un acercamiento pluridisciplinar al problema que incluye el estudio de los diferentes materiales que constituyen la estructura multicapa que forma un SMR, el diseño y fabricación del dispositivo y del sistema de fluídica, la funcionalización bioquímica de la superficie del sensor, la demostración de la capacidad de detección de especies biológicas y finalmente el diseño y fabricación de la electrónica asociada para la detección de la señal eléctrica. Todas esas tareas han sido abordadas en las distintas etapas del desarrollo de esta tesis y las contribuciones más relevantes se describen en el documento. En el campo de desarrollo de los materiales, se propone un proceso en dos etapas para la pulverización reactiva de capas de A1N que contengan microcristales inclinados capaces de excitar el modo de cizalladura. Se caracteriza la velocidad acústica del modo de cizalladura en todos los materiales que componen la estructura, con el fin de poder obtener un diseño más adecuado del reflector acústico. Se propone un nuevo tipo de material aislante de alta impedancia acústica consistente en capas de W03 pulverizadas que presenta ciertas ventajas tecnológicas frente a las capas convencionales de Ta205. Respecto del diseño del transductor, se estudia la influencia que tienen los con tactos eléctricos extendidos del resonador necesarios para poder adaptar el sistema de fluídica a la estructura. Los resultados indican que es necesario trabajar sobre sustratos aislantes (tanto el soporte como el espejo acústico) para evitar efectos parásitos asociados al uso de capas metálicas bajo los electrodos del resonador que dañan su resonancia. Se analiza la influencia de las diferentes capas del dispositivo en el coeficiente de temperatura de la frecuencia (TCF) del resonador llegando a la conclusión de que las dos últimas capas del reflector acústico afectan significativamente al TCF del SMR, pudiendo reducirse ajusfando adecuadamente sus espesores. De acuerdo con los resultados de estos estudios, se han diseñado finalmente resonadores SMR operando a f .3 GHz en modo de cizalladura, con un área activa de 65000 /xm2, contactos eléctricos que se extienden f .7 mm y factores de calidad en líquido de f 50. Las extensiones eléctricas permiten adaptar el resonador a un sistema de fluídica de metacrilato. Para la detección de especies biológicas se realiza un montaje experimental que permite circular 800 ¡A por la superficie del sensor a través de un circuito cerrado que trabaja a volumen constante. La circulación de soluciones iónicas sobre el sensor descubierto pone de manifiesto que las altas frecuencias de operación previenen los cortocircuitos y por tanto el aislamiento de los electrodos es prescindible. Se desarrolla un protocolo ad-hoc de funcionalización basado en el proceso estándar APTESGlutaraldehído. Se proponen dos alternativas novedosas para la funcionalización de las áreas activas del sensor basadas en el uso de capas de oxidación de Ir02 y su activación a través de un plasma de oxígeno que no daña al dispositivo. Ambos procesos contribuyen a simplificar notablemente la funcionalización de los sensores gravimétricos. Se utilizan anticuerpos y aptámeros como receptores para detectar trombina, anticuerpo monoclonal IgG de ratón y bacteria sonicadas. Una calibración preliminar del sensor con depósitos de capas finas de Si02 de densidad y espesor conocidos permite obtener una sensibilidad de 1800 kHz/pg-cm2 y un límite de detección of 4.2 pg. Finalmente se propone el prototipo de un circuito electrónico de excitación y lectura de bajo coste diseñado empleando teoría de circuitos de microondas. Aunque su diseño y funcionamiento admite mejoras, constituye la última etapa de un sistema completo de bajo coste para el diagnóstico de especies biológicas basado en resonadores SMR de A1N. ABSTRACT Early diagnosis and detection of diseases are essential for reducing mortality rate and preventing long-term hospitalization and waste of resources. These requirements have boosted the efforts and funding on the research of accurate and reliable means for detection and quantification of biological species, also known as biosensors. The work presented in this thesis describes the development and fabrication of gravimetric biosensors based on piezoelectric AlN bulk acoustic wave (BAW) solidly mounted resonators (SMRs) for detection of biological species in liquid media. These type of devices base their sensing principles in the variation that their resonant frequency suffers when a mass is attached to their surface. They need to operate in the shear mode to maintain a strong resonance in liquid and an adequate functionalisation of their sensing area to guarantee that only the targeted molecules cause the shift. The challenges that need to be overcome to achieve piezoelectric BAW resonators for high sensitivity detection in fluids require a multidisciplinary approach, that include the study of the materials involved, the design of the device and the fluidic system, the biochemical functionalisation of the active area, the experimental proof-of-concept with different target species and the design of an electronic readout circuit. All this tasks have been tackled at different stages of the thesis and the relevant contributions are described in the document. In the field of materials, a two-stage sputtering deposition process has been developed to obtain good-quality AlN films with uniformly tilted grains required to excite the shear mode. The shear acoustic velocities of the materials composing the acoustic reflector have been accurately studied to ensure an optimum design of the reflector stack. WO3 sputtered films have been proposed as high acoustic impedance material for insulating acoustic reflectors. They display several technological advantages for the processing of the resonators. Regarding the design, a study of the influence of the electrical extensions necessary to fit a fluidic system on the performance of the devices has been performed. The results indicate that high resistivity substrates and insulating reflectors are necessary to avoid the hindering of the resonance due to the parasitic effects induced by the extensions. The influence of the different layers of the stack on the resultant TCF of the SMRs has also been investigated. The two layers of the reflector closer to the piezoelectric layer have a significant influence on the TCF, which can be reduced by modifying their thicknesses accordingly. The data provided by these studies has led to the final design of the devices, which operate at 1.3 GHz in the shear mode and display an active area of 65000 /xm2 and electrical extensions of 1.7 mm while keeping a Qahear=150 in liquid. The extensions enable to fit a custom-made fluidic system made of methacrylate. To perform the biosensing experiments, an experimental setup with a liquid closed circuit operating at constant flow has been developed. Buffers of ionic characteristics have been tested on non-isolated devices, revealing that high operation frequencies prevent the risk of short circuit. An ad-hoc functionalisation protocol based on the standard APTES - Glutaraldehyde process has been developed. It includes two new processes that simplify the fabrication of the transducers: the use of IrO2 as oxidation layer and its functionalisation through an O2 plasma treatment that does not damage the resonators. Both antibodies and aptamers are used as receptors. In liquid sensing proof-of-concept experiments with thrombin, IgG mouse monoclonal antibody and sonicated bacteria have been displayed. A preliminary calibration of the devices using SiO2 layers reveals a sensitivity of 1800 kHz/pg-cm2 and a limit of detection of 4.2 pg. Finally, a first prototype of a low-cost electronic readout circuit designed using a standard microwave approach has been developed. Although its performance can be significantly improved, it is an effective first approach to the final stage of a portable low-cost diagnostic system based on shear mode AlN SMRs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El análisis determinista de seguridad (DSA) es el procedimiento que sirve para diseñar sistemas, estructuras y componentes relacionados con la seguridad en las plantas nucleares. El DSA se basa en simulaciones computacionales de una serie de hipotéticos accidentes representativos de la instalación, llamados escenarios base de diseño (DBS). Los organismos reguladores señalan una serie de magnitudes de seguridad que deben calcularse en las simulaciones, y establecen unos criterios reguladores de aceptación (CRA), que son restricciones que deben cumplir los valores de esas magnitudes. Las metodologías para realizar los DSA pueden ser de 2 tipos: conservadoras o realistas. Las metodologías conservadoras utilizan modelos predictivos e hipótesis marcadamente pesimistas, y, por ello, relativamente simples. No necesitan incluir un análisis de incertidumbre de sus resultados. Las metodologías realistas se basan en hipótesis y modelos predictivos realistas, generalmente mecanicistas, y se suplementan con un análisis de incertidumbre de sus principales resultados. Se les denomina también metodologías BEPU (“Best Estimate Plus Uncertainty”). En ellas, la incertidumbre se representa, básicamente, de manera probabilista. Para metodologías conservadores, los CRA son, simplemente, restricciones sobre valores calculados de las magnitudes de seguridad, que deben quedar confinados en una “región de aceptación” de su recorrido. Para metodologías BEPU, el CRA no puede ser tan sencillo, porque las magnitudes de seguridad son ahora variables inciertas. En la tesis se desarrolla la manera de introducción de la incertidumbre en los CRA. Básicamente, se mantiene el confinamiento a la misma región de aceptación, establecida por el regulador. Pero no se exige el cumplimiento estricto sino un alto nivel de certidumbre. En el formalismo adoptado, se entiende por ello un “alto nivel de probabilidad”, y ésta corresponde a la incertidumbre de cálculo de las magnitudes de seguridad. Tal incertidumbre puede considerarse como originada en los inputs al modelo de cálculo, y propagada a través de dicho modelo. Los inputs inciertos incluyen las condiciones iniciales y de frontera al cálculo, y los parámetros empíricos de modelo, que se utilizan para incorporar la incertidumbre debida a la imperfección del modelo. Se exige, por tanto, el cumplimiento del CRA con una probabilidad no menor a un valor P0 cercano a 1 y definido por el regulador (nivel de probabilidad o cobertura). Sin embargo, la de cálculo de la magnitud no es la única incertidumbre existente. Aunque un modelo (sus ecuaciones básicas) se conozca a la perfección, la aplicación input-output que produce se conoce de manera imperfecta (salvo que el modelo sea muy simple). La incertidumbre debida la ignorancia sobre la acción del modelo se denomina epistémica; también se puede decir que es incertidumbre respecto a la propagación. La consecuencia es que la probabilidad de cumplimiento del CRA no se puede conocer a la perfección; es una magnitud incierta. Y así se justifica otro término usado aquí para esta incertidumbre epistémica: metaincertidumbre. Los CRA deben incorporar los dos tipos de incertidumbre: la de cálculo de la magnitud de seguridad (aquí llamada aleatoria) y la de cálculo de la probabilidad (llamada epistémica o metaincertidumbre). Ambas incertidumbres pueden introducirse de dos maneras: separadas o combinadas. En ambos casos, el CRA se convierte en un criterio probabilista. Si se separan incertidumbres, se utiliza una probabilidad de segundo orden; si se combinan, se utiliza una probabilidad única. Si se emplea la probabilidad de segundo orden, es necesario que el regulador imponga un segundo nivel de cumplimiento, referido a la incertidumbre epistémica. Se denomina nivel regulador de confianza, y debe ser un número cercano a 1. Al par formado por los dos niveles reguladores (de probabilidad y de confianza) se le llama nivel regulador de tolerancia. En la Tesis se razona que la mejor manera de construir el CRA BEPU es separando las incertidumbres, por dos motivos. Primero, los expertos defienden el tratamiento por separado de incertidumbre aleatoria y epistémica. Segundo, el CRA separado es (salvo en casos excepcionales) más conservador que el CRA combinado. El CRA BEPU no es otra cosa que una hipótesis sobre una distribución de probabilidad, y su comprobación se realiza de forma estadística. En la tesis, los métodos estadísticos para comprobar el CRA BEPU en 3 categorías, según estén basados en construcción de regiones de tolerancia, en estimaciones de cuantiles o en estimaciones de probabilidades (ya sea de cumplimiento, ya sea de excedencia de límites reguladores). Según denominación propuesta recientemente, las dos primeras categorías corresponden a los métodos Q, y la tercera, a los métodos P. El propósito de la clasificación no es hacer un inventario de los distintos métodos en cada categoría, que son muy numerosos y variados, sino de relacionar las distintas categorías y citar los métodos más utilizados y los mejor considerados desde el punto de vista regulador. Se hace mención especial del método más utilizado hasta el momento: el método no paramétrico de Wilks, junto con su extensión, hecha por Wald, al caso multidimensional. Se decribe su método P homólogo, el intervalo de Clopper-Pearson, típicamente ignorado en el ámbito BEPU. En este contexto, se menciona el problema del coste computacional del análisis de incertidumbre. Los métodos de Wilks, Wald y Clopper-Pearson requieren que la muestra aleatortia utilizada tenga un tamaño mínimo, tanto mayor cuanto mayor el nivel de tolerancia exigido. El tamaño de muestra es un indicador del coste computacional, porque cada elemento muestral es un valor de la magnitud de seguridad, que requiere un cálculo con modelos predictivos. Se hace especial énfasis en el coste computacional cuando la magnitud de seguridad es multidimensional; es decir, cuando el CRA es un criterio múltiple. Se demuestra que, cuando las distintas componentes de la magnitud se obtienen de un mismo cálculo, el carácter multidimensional no introduce ningún coste computacional adicional. Se prueba así la falsedad de una creencia habitual en el ámbito BEPU: que el problema multidimensional sólo es atacable desde la extensión de Wald, que tiene un coste de computación creciente con la dimensión del problema. En el caso (que se da a veces) en que cada componente de la magnitud se calcula independientemente de los demás, la influencia de la dimensión en el coste no se puede evitar. Las primeras metodologías BEPU hacían la propagación de incertidumbres a través de un modelo sustitutivo (metamodelo o emulador) del modelo predictivo o código. El objetivo del metamodelo no es su capacidad predictiva, muy inferior a la del modelo original, sino reemplazar a éste exclusivamente en la propagación de incertidumbres. Para ello, el metamodelo se debe construir con los parámetros de input que más contribuyan a la incertidumbre del resultado, y eso requiere un análisis de importancia o de sensibilidad previo. Por su simplicidad, el modelo sustitutivo apenas supone coste computacional, y puede estudiarse exhaustivamente, por ejemplo mediante muestras aleatorias. En consecuencia, la incertidumbre epistémica o metaincertidumbre desaparece, y el criterio BEPU para metamodelos se convierte en una probabilidad simple. En un resumen rápido, el regulador aceptará con más facilidad los métodos estadísticos que menos hipótesis necesiten; los exactos más que los aproximados; los no paramétricos más que los paramétricos, y los frecuentistas más que los bayesianos. El criterio BEPU se basa en una probabilidad de segundo orden. La probabilidad de que las magnitudes de seguridad estén en la región de aceptación no sólo puede asimilarse a una probabilidad de éxito o un grado de cumplimiento del CRA. También tiene una interpretación métrica: representa una distancia (dentro del recorrido de las magnitudes) desde la magnitud calculada hasta los límites reguladores de aceptación. Esta interpretación da pie a una definición que propone esta tesis: la de margen de seguridad probabilista. Dada una magnitud de seguridad escalar con un límite superior de aceptación, se define el margen de seguridad (MS) entre dos valores A y B de la misma como la probabilidad de que A sea menor que B, obtenida a partir de las incertidumbres de A y B. La definición probabilista de MS tiene varias ventajas: es adimensional, puede combinarse de acuerdo con las leyes de la probabilidad y es fácilmente generalizable a varias dimensiones. Además, no cumple la propiedad simétrica. El término margen de seguridad puede aplicarse a distintas situaciones: distancia de una magnitud calculada a un límite regulador (margen de licencia); distancia del valor real de la magnitud a su valor calculado (margen analítico); distancia desde un límite regulador hasta el valor umbral de daño a una barrera (margen de barrera). Esta idea de representar distancias (en el recorrido de magnitudes de seguridad) mediante probabilidades puede aplicarse al estudio del conservadurismo. El margen analítico puede interpretarse como el grado de conservadurismo (GC) de la metodología de cálculo. Utilizando la probabilidad, se puede cuantificar el conservadurismo de límites de tolerancia de una magnitud, y se pueden establecer indicadores de conservadurismo que sirvan para comparar diferentes métodos de construcción de límites y regiones de tolerancia. Un tópico que nunca se abordado de manera rigurosa es el de la validación de metodologías BEPU. Como cualquier otro instrumento de cálculo, una metodología, antes de poder aplicarse a análisis de licencia, tiene que validarse, mediante la comparación entre sus predicciones y valores reales de las magnitudes de seguridad. Tal comparación sólo puede hacerse en escenarios de accidente para los que existan valores medidos de las magnitudes de seguridad, y eso ocurre, básicamente en instalaciones experimentales. El objetivo último del establecimiento de los CRA consiste en verificar que se cumplen para los valores reales de las magnitudes de seguridad, y no sólo para sus valores calculados. En la tesis se demuestra que una condición suficiente para este objetivo último es la conjunción del cumplimiento de 2 criterios: el CRA BEPU de licencia y un criterio análogo, pero aplicado a validación. Y el criterio de validación debe demostrarse en escenarios experimentales y extrapolarse a plantas nucleares. El criterio de licencia exige un valor mínimo (P0) del margen probabilista de licencia; el criterio de validación exige un valor mínimo del margen analítico (el GC). Esos niveles mínimos son básicamente complementarios; cuanto mayor uno, menor el otro. La práctica reguladora actual impone un valor alto al margen de licencia, y eso supone que el GC exigido es pequeño. Adoptar valores menores para P0 supone menor exigencia sobre el cumplimiento del CRA, y, en cambio, más exigencia sobre el GC de la metodología. Y es importante destacar que cuanto mayor sea el valor mínimo del margen (de licencia o analítico) mayor es el coste computacional para demostrarlo. Así que los esfuerzos computacionales también son complementarios: si uno de los niveles es alto (lo que aumenta la exigencia en el cumplimiento del criterio) aumenta el coste computacional. Si se adopta un valor medio de P0, el GC exigido también es medio, con lo que la metodología no tiene que ser muy conservadora, y el coste computacional total (licencia más validación) puede optimizarse. ABSTRACT Deterministic Safety Analysis (DSA) is the procedure used in the design of safety-related systems, structures and components of nuclear power plants (NPPs). DSA is based on computational simulations of a set of hypothetical accidents of the plant, named Design Basis Scenarios (DBS). Nuclear regulatory authorities require the calculation of a set of safety magnitudes, and define the regulatory acceptance criteria (RAC) that must be fulfilled by them. Methodologies for performing DSA van be categorized as conservative or realistic. Conservative methodologies make use of pessimistic model and assumptions, and are relatively simple. They do not need an uncertainty analysis of their results. Realistic methodologies are based on realistic (usually mechanistic) predictive models and assumptions, and need to be supplemented with uncertainty analyses of their results. They are also termed BEPU (“Best Estimate Plus Uncertainty”) methodologies, and are typically based on a probabilistic representation of the uncertainty. For conservative methodologies, the RAC are simply the restriction of calculated values of safety magnitudes to “acceptance regions” defined on their range. For BEPU methodologies, the RAC cannot be so simple, because the safety magnitudes are now uncertain. In the present Thesis, the inclusion of uncertainty in RAC is studied. Basically, the restriction to the acceptance region must be fulfilled “with a high certainty level”. Specifically, a high probability of fulfillment is required. The calculation uncertainty of the magnitudes is considered as propagated from inputs through the predictive model. Uncertain inputs include model empirical parameters, which store the uncertainty due to the model imperfection. The fulfillment of the RAC is required with a probability not less than a value P0 close to 1 and defined by the regulator (probability or coverage level). Calculation uncertainty is not the only one involved. Even if a model (i.e. the basic equations) is perfectly known, the input-output mapping produced by the model is imperfectly known (unless the model is very simple). This ignorance is called epistemic uncertainty, and it is associated to the process of propagation). In fact, it is propagated to the probability of fulfilling the RAC. Another term used on the Thesis for this epistemic uncertainty is metauncertainty. The RAC must include the two types of uncertainty: one for the calculation of the magnitude (aleatory uncertainty); the other one, for the calculation of the probability (epistemic uncertainty). The two uncertainties can be taken into account in a separate fashion, or can be combined. In any case the RAC becomes a probabilistic criterion. If uncertainties are separated, a second-order probability is used; of both are combined, a single probability is used. On the first case, the regulator must define a level of fulfillment for the epistemic uncertainty, termed regulatory confidence level, as a value close to 1. The pair of regulatory levels (probability and confidence) is termed the regulatory tolerance level. The Thesis concludes that the adequate way of setting the BEPU RAC is by separating the uncertainties. There are two reasons to do so: experts recommend the separation of aleatory and epistemic uncertainty; and the separated RAC is in general more conservative than the joint RAC. The BEPU RAC is a hypothesis on a probability distribution, and must be statistically tested. The Thesis classifies the statistical methods to verify the RAC fulfillment in 3 categories: methods based on tolerance regions, in quantile estimators and on probability (of success or failure) estimators. The former two have been termed Q-methods, whereas those in the third category are termed P-methods. The purpose of our categorization is not to make an exhaustive survey of the very numerous existing methods. Rather, the goal is to relate the three categories and examine the most used methods from a regulatory standpoint. Special mention deserves the most used method, due to Wilks, and its extension to multidimensional variables (due to Wald). The counterpart P-method of Wilks’ is Clopper-Pearson interval, typically ignored in the BEPU realm. The problem of the computational cost of an uncertainty analysis is tackled. Wilks’, Wald’s and Clopper-Pearson methods require a minimum sample size, which is a growing function of the tolerance level. The sample size is an indicator of the computational cost, because each element of the sample must be calculated with the predictive models (codes). When the RAC is a multiple criteria, the safety magnitude becomes multidimensional. When all its components are output of the same calculation, the multidimensional character does not introduce additional computational cost. In this way, an extended idea in the BEPU realm, stating that the multi-D problem can only be tackled with the Wald extension, is proven to be false. When the components of the magnitude are independently calculated, the influence of the problem dimension on the cost cannot be avoided. The former BEPU methodologies performed the uncertainty propagation through a surrogate model of the code, also termed emulator or metamodel. The goal of a metamodel is not the predictive capability, clearly worse to the original code, but the capacity to propagate uncertainties with a lower computational cost. The emulator must contain the input parameters contributing the most to the output uncertainty, and this requires a previous importance analysis. The surrogate model is practically inexpensive to run, so that it can be exhaustively analyzed through Monte Carlo. Therefore, the epistemic uncertainty due to sampling will be reduced to almost zero, and the BEPU RAC for metamodels includes a simple probability. The regulatory authority will tend to accept the use of statistical methods which need a minimum of assumptions: exact, nonparametric and frequentist methods rather than approximate, parametric and bayesian methods, respectively. The BEPU RAC is based on a second-order probability. The probability of the safety magnitudes being inside the acceptance region is a success probability and can be interpreted as a fulfillment degree if the RAC. Furthermore, it has a metric interpretation, as a distance (in the range of magnitudes) from calculated values of the magnitudes to acceptance regulatory limits. A probabilistic definition of safety margin (SM) is proposed in the thesis. The same from a value A to other value B of a safety magnitude is defined as the probability that A is less severe than B, obtained from the uncertainties if A and B. The probabilistic definition of SM has several advantages: it is nondimensional, ranges in the interval (0,1) and can be easily generalized to multiple dimensions. Furthermore, probabilistic SM are combined according to the probability laws. And a basic property: probabilistic SM are not symmetric. There are several types of SM: distance from a calculated value to a regulatory limit (licensing margin); or from the real value to the calculated value of a magnitude (analytical margin); or from the regulatory limit to the damage threshold (barrier margin). These representations of distances (in the magnitudes’ range) as probabilities can be applied to the quantification of conservativeness. Analytical margins can be interpreted as the degree of conservativeness (DG) of the computational methodology. Conservativeness indicators are established in the Thesis, useful in the comparison of different methods of constructing tolerance limits and regions. There is a topic which has not been rigorously tackled to the date: the validation of BEPU methodologies. Before being applied in licensing, methodologies must be validated, on the basis of comparisons of their predictions ad real values of the safety magnitudes. Real data are obtained, basically, in experimental facilities. The ultimate goal of establishing RAC is to verify that real values (aside from calculated values) fulfill them. In the Thesis it is proved that a sufficient condition for this goal is the conjunction of 2 criteria: the BEPU RAC and an analogous criterion for validation. And this las criterion must be proved in experimental scenarios and extrapolated to NPPs. The licensing RAC requires a minimum value (P0) of the probabilistic licensing margin; the validation criterion requires a minimum value of the analytical margin (i.e., of the DG). These minimum values are basically complementary; the higher one of them, the lower the other one. The regulatory practice sets a high value on the licensing margin, so that the required DG is low. The possible adoption of lower values for P0 would imply weaker exigence on the RCA fulfillment and, on the other hand, higher exigence on the conservativeness of the methodology. It is important to highlight that a higher minimum value of the licensing or analytical margin requires a higher computational cost. Therefore, the computational efforts are also complementary. If medium levels are adopted, the required DG is also medium, and the methodology does not need to be very conservative. The total computational effort (licensing plus validation) could be optimized.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El propósito de esta tesis es presentar una metodología para realizar análisis de la dinámica en pequeña señal y el comportamiento de sistemas de alimentación distribuidos de corriente continua (CC), formados por módulos comerciales. Para ello se hace uso de un método sencillo que indica los márgenes de estabilidad menos conservadores posibles mediante un solo número. Este índice es calculado en cada una de las interfaces que componen el sistema y puede usarse para obtener un índice global que indica la estabilidad del sistema global. De esta manera se posibilita la comparación de sistemas de alimentación distribuidos en términos de robustez. La interconexión de convertidores CC-CC entre ellos y con los filtros EMI necesarios puede originar interacciones no deseadas que dan lugar a la degradación del comportamiento de los convertidores, haciendo el sistema más propenso a inestabilidades. Esta diferencia en el comportamiento se debe a interacciones entre las impedancias de los diversos elementos del sistema. En la mayoría de los casos, los sistemas de alimentación distribuida están formados por módulos comerciales cuya estructura interna es desconocida. Por ello los análisis presentados en esta tesis se basan en medidas de la respuesta en frecuencia del convertidor que pueden realizarse desde los terminales de entrada y salida del mismo. Utilizando las medidas de las impedancias de entrada y salida de los elementos del sistema, se puede construir una función de sensibilidad que proporciona los márgenes de estabilidad de las diferentes interfaces. En esta tesis se utiliza el concepto del valor máximo de la función de sensibilidad (MPC por sus siglas en inglés) para indicar los márgenes de estabilidad como un único número. Una vez que la estabilidad de todas las interfaces del sistema se han evaluado individualmente, los índices obtenidos pueden combinarse para obtener un único número con el que comparar la estabilidad de diferentes sistemas. Igualmente se han analizado las posibles interacciones en la entrada y la salida de los convertidores CC-CC, obteniéndose expresiones analíticas con las que describir en detalle los acoplamientos generados en el sistema. Los estudios analíticos realizados se han validado experimentalmente a lo largo de la tesis. El análisis presentado en esta tesis se culmina con la obtención de un índice que condensa los márgenes de estabilidad menos conservativos. También se demuestra que la robustez del sistema está asegurada si las impedancias utilizadas en la función de sensibilidad se obtienen justamente en la entrada o la salida del subsistema que está siendo analizado. Por otra parte, la tesis presenta un conjunto de parámetros internos asimilados a impedancias, junto con sus expresiones analíticas, que permiten una explicación detallada de las interacciones en el sistema. Dichas expresiones analíticas pueden obtenerse bien mediante las funciones de transferencia analíticas si se conoce la estructura interna, o utilizando medidas en frecuencia o identificación de las mismas a través de la respuesta temporal del convertidor. De acuerdo a las metodologías presentadas en esta tesis se puede predecir la estabilidad y el comportamiento de sistemas compuestos básicamente por convertidores CC-CC y filtros, cuya estructura interna es desconocida. La predicción se basa en un índice que condensa la información de los márgenes de estabilidad y que permite la obtención de un indicador de la estabilidad global de todo el sistema, permitiendo la comparación de la estabilidad de diferentes arquitecturas de sistemas de alimentación distribuidos. ABSTRACT The purpose of this thesis is to present dynamic small-signal stability and performance analysis methodology for dc-distributed systems consisting of commercial power modules. Furthermore, the objective is to introduce simple method to state the least conservative margins for robust stability as a single number. In addition, an index characterizing the overall system stability is obtained, based on which different dc-distributed systems can be compared in terms of robustness. The interconnected systems are prone to impedance-based interactions which might lead to transient-performance degradation or even instability. These systems typically are constructed using commercial converters with unknown internal structure. Therefore, the analysis presented throughout this thesis is based on frequency responses measurable from the input and output terminals. The stability margins are stated utilizing a concept of maximum peak criteria, derived from the behavior of impedance-based sensitivity function that provides a single number to state robust stability. Using this concept, the stability information at every system interface is combined to a meaningful number to state the average robustness of the system. In addition, theoretical formulas are extracted to assess source and load side interactions in order to describe detailed couplings within the system. The presented theoretical analysis methodologies are experimentally validated throughout the thesis. In this thesis, according to the presented analysis, the least conservative stability margins are provided as a single number guaranteeing robustness. It is also shown that within the interconnected system the robust stability is ensured only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem. Moreover, a complete set of impedance-type internal parameters as well as the formulas according to which the interaction sensitivity can be fully explained and analyzed, is provided. The given formulation can be utilized equally either based on measured frequency responses, time-domain identified internal parameters or extracted analytic transfer functions. Based on the analysis methodologies presented in this thesis, the stability and performance of interconnected systems consisting of converters with unknown internal structure, can be predicted. Moreover, the provided concept to assess the least conservative stability margins enables to obtain an index to state the overall robust stability of distributed power architecture and thus to compare different systems in terms of stability.