120 resultados para Concrete beams.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se describe el problema del hinchamiento del hormigón en las presas de doble curvatura. Several chemical reactions are able to produce swelling of concrete for decades after its initial curing, a problem that affects a considerable number of concrete dams around the world. The object of the work reported is to simulate the underlying mechanisms with sufficient accuracy to reproduce the past history and to predict the future evolution reliably. Having studied the available formulations, that considered to be more promising was adopted and introduced via user routines in a commercial finite element code. It is a non isotropic swelling model,compatible with the cracking and other non-linearities displayed by the concrete. The paper concentrates on the work conducted for a double-curvature arch dam. The model parameters were determined on the basis of some parts of the dam’s monitored histories, reliability was then verified using other parts and, finally, predictions were made about the future evolution of the dam and its safety margin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La aparición de la fatiga ha sido ampliamente investigada en el acero y en otros materiales metálicos, sin embargo no se conoce en tanta profundidad en el hormigón estructural. Esto crea falta de uniformidad y enfoque en el proceso de verificación de estructuras de hormigón para el estado límite último de la fatiga. A medida que se llevan a cabo más investigaciones, la información sobre los parámetros que afectan a la fatiga en el hormigón comienzan a ser difundidos e incluso los que les afectan de forma indirecta. Esto conlleva a que se estén incorporando en las guías de diseño de todo el mundo, a pesar de que la comprobación del estado límite último no se trata por igual entre los distintos órganos de diseño. Este trabajo presentará un conocimiento básico del fenómeno de la fatiga, qué lo causa y qué condiciones de carga o propiedades materiales amplían o reducen la probabilidad de fallo por fatiga. Cuatro distintos códigos de diseño serán expuestos y su proceso de verificación ha sido examinado, comparados y valorados cualitativa y cuantitativamente. Una torre eólica, como ejemplo, fue analizada usando los procedimientos de verificación como se indica en sus respectivos códigos de referencia. The occurrence of fatigue has been extensively researched in steel and other metallic materials it is however, not as broadly understood in concrete. This produces a lack of uniformity in the approach and process in the verification of concrete structures for the ultimate limit state of fatigue. As more research is conducted and more information is known about the parameters which cause, propagate, and indirectly affect fatigue in concrete, they are incorporated in design guides around the world. Nevertheless, this ultimate limit state verification is not addressed equally by various design governing bodies. This report presents a baseline understanding of what the phenomenon of fatigue is, what causes it, and what loading or material conditions amplify or reduce the likelihood of fatigue failure. Four different design codes are exposed and their verification process has been examined, compared and evaluated both qualitatively and quantitatively. Using a wind turbine tower structure as case study, this report presents calculated results following the verification processes as instructed in the respective reference codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bond analytical model is proposed in this paper. The model is capable of reproducing the bond stress developed between the steel and concrete, in precast prestressed elements, during the entire process of prestressing force release. The bond stress developed in the transmission zone, where the bond stress is not constant, is also obtained. The steel and concrete stresses as well as the slip between both materials can be also estimated by means of the relation established in the model between these parameters and the bond stress. The model is validated with the results of a series of tests, considering different steel indentation depths and concrete covers and it is extended to evaluate the transmission length. This has been checked by comparing the transmission length predicted by the model and one measured experimentally in two series of tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo trata de elementos reforzados con barras de armadura y Fibras Metálicas Recicladas (FMR). El objetivo principal es mejorar el comportamiento a fisuración de elementos sometidos a flexión pura y a flexión compuesta, aumentando en consecuencia las prestaciones en servicio de aquellas estructuras con requerimientos estrictos con respecto al control de fisuración. Entre éstas últimas se encuentran las estructuras integrales, es decir aquellas estructuras sin juntas (puentes o edificios), sometidas a cargas gravitatorias y deformaciones impuestas en los elementos horizontales debidas a retracción, fluencia y temperatura. Las FMR son obtenidas a partir de los neumáticos fuera de uso, y puesto que el procedimiento de reciclado se centra en el caucho en vez que en el acero, su forma es aleatoria y con longitud variable. A pesar de que la eficacia del fibrorefuerzo mediante FMR ha sido demostrada en investigaciones anteriores, la innovación que representa este trabajo consiste en proponer la acción combinada de barras convencionales y FMR en la mejora del comportamiento a fisuración. El objetivo es por tanto mejorar la sostenibilidad del proyecto de la estructura en HA al utilizar materiales reciclados por un lado, y aumentando por el otro la durabilidad. En primer lugar, se presenta el estado del arte con respecto a la fisuración en elementos de HA, que sucesivamente se amplía a elementos reforzados con barras y fibras. Asimismo, se resume el método simplificado para el análisis de columnas de estructuras sin juntas ya propuesto por Pérez et al., con particular énfasis en aquellos aspectos que son incompatibles con la acción de las fibras a nivel seccional. A continuación, se presenta un modelo para describir la deformabilidad seccional y la fisuración en elementos en HA, que luego se amplía a aquellos elementos reforzados con barras y fibras, teniendo en cuenta también los efectos debidos a la retracción (tension stiffening negativo). El modelo es luego empleado para ampliar el método simplificado para el análisis de columnas. La aportación consiste por tanto en contar con una metodología amplia de análisis para este tipo de elementos. Seguidamente, se presenta la campaña experimental preliminar que ha involucrado vigas a escala reducida sometidas a flexión simple, con el objetivo de validar la eficiencia y la usabilidad en el hormigón de las FMR de dos diferentes tipos, y su comportamiento con respecto a fibras de acero comerciales. Se describe a continuación la campaña principal, consistente en ensayos sobre ocho vigas en flexión simple a escala 1:1 (variando contenido en FRM, Ø/s,eff y recubrimiento) y doce columnas a flexión compuesta (variando contenido en FMR, Ø/s,eff y nivel de fuerza axil). Los resultados obtenidos en la campaña principal son presentados y comentados, resaltando las mejoras obtenidas en el comportamiento a fisuración de las vigas y columnas, y la rigidez estructural de las columnas. Estos resultados se comparan con las predicciones del modelo propuesto. Los principales parámetros estudiados para describir la fisuración y el comportamiento seccional de las vigas son: la separación entre fisuras, el alargamiento medio de las armaduras y la abertura de fisura, mientras que en los ensayos de las columnas se ha contrastado las leyes momento/curvatura, la tensión en las barras de armadura y la abertura de fisura en el empotramiento en la base. La comparación muestra un buen acuerdo entre las predicciones y los resultados experimentales. Asimismo, se nota la mejora en el comportamiento a fisuración debido a la incorporación de FMR en aquellos elementos con cuantías de armadura bajas en flexión simple, en elementos con axiles bajos y para el control de la fisuración en elementos con grandes recubrimientos, siendo por tanto resultados de inmediato impacto en la práctica ingenieril (diseño de losas, tanques, estructuras integrales, etc.). VIIIComo punto final, se presentan aplicaciones de las FMR en estructuras reales. Se discuten dos casos de elementos sometidos a flexión pura, en particular una viga simplemente apoyada y un tanque para el tratamiento de agua. En ambos casos la adicción de FMR al hormigón lleva a mejoras en el comportamiento a fisuración. Luego, utilizando el método simplificado para el análisis en servicio de columnas de estructuras sin juntas, se calcula la máxima longitud admisible en casos típicos de puentes y edificación. En particular, se demuestra que las limitaciones de la práctica ingenieril actual (sobre todo en edificación) pueden ser aumentadas considerando el comportamiento real de las columnas en HA. Finalmente, los mismos casos son modificados para considerar el uso de MFR, y se presentan las mejoras tanto en la máxima longitud admisible como en la abertura de fisura para una longitud y deformación impuesta. This work deals with elements reinforced with both rebars and Recycled Steel Fibres (RSFs). Its main objective is to improve cracking behaviour of elements subjected to pure bending and bending and axial force, resulting in better serviceability conditions for these structures demanding keen crack width control. Among these structures a particularly interesting type are the so-called integral structures, i.e. long jointless structures (bridges and buildings) subjected to gravitational loads and imposed deformations due to shrinkage, creep and temperature. RSFs are obtained from End of Life Tyres, and due to the recycling process that is focused on the rubber rather than on the steel they come out crooked and with variable length. Although the effectiveness of RSFs had already been proven by previous research, the innovation of this work consists in the proposing the combined action of conventional rebars and RSFs to improve cracking behaviour. Therefore, the objective is to improve the sustainability of RC structures by, on the one hand, using recycled materials, and on the other improving their durability. A state of the art on cracking in RC elements is firstly drawn. It is then expanded to elements reinforced with both rebars and fibres (R/FRC elements). Finally, the simplified method for analysis of columns of long jointless structures already proposed by Pérez et al. is resumed, with a special focus on the points that conflict when taking into account the action of fibres. Afterwards, a model to describe sectional deformability and cracking of R/FRC elements is presented, taking also into account the effect of shrinkage (negative tension stiffening). The model is then used to implement the simplified method for columns. The novelty represented by this is that a comprehensive methodology to analyse this type of elements is presented. A preliminary experimental campaign consisting in small beams subjected to pure bending is described, with the objective of validating the effectiveness and usability in concrete of RSFs of two different types, and their behaviour when compared with commercial steel fibres. With the results and lessons learnt from this campaign in mind, the main experimental campaign is then described, consisting in cracking tests of eight unscaled beams in pure bending (varying RSF content, Ø/s,eff and concrete cover) and twelve columns subjected to imposed displacement and axial force (varying RSF content, Ø/s,eff and squashing load ratio). The results obtained from the main campaign are presented and discussed, with particular focus on the improvement in cracking behaviour for the beams and columns, and structural stiffness for the columns. They are then compared with the proposed model. The main parameters studied to describe cracking and sectional behaviours of the beam tests are crack spacing, mean steel strain and crack width, while for the column tests these were moment/curvature, stress in rebars and crack with at column embedment. The comparison showed satisfactory agreement between experimental results and model predictions. Moreover, it is pointed out the improvement in cracking behaviour due to the addition of RSF for elements with low reinforcement ratios, elements with low squashing load ratios and for crack width control of elements with large concrete covers, thus representing results with a immediate impact in engineering practice (slab design, tanks, integral structures, etc.). Applications of RSF to actual structures are finally presented. Two cases of elements in pure bending are presented, namely a simple supported beam and a water treatment tank. In both cases the addition of RSF to concrete leads to improvements in cracking behaviour. Then, using the simplified model for the serviceability analysis of columns of jointless structures, the maximum achievable jointless length of typical cases of a bridge and building is obtained. In XIIparticular, it is shown how the limitations of current engineering practice (this is especially the case of buildings) can be increased by considering the actual behaviour of RC supports. Then, the same cases are modified considering the use of RSF, and the improvements both in maximum achievable length and in crack width for a given length and imposed strain at the deck/first floor are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio de soluciones prefabricadas de hormigón no estandarizadas en los Países Bajos tras la Segunda Guerra Mundial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to explain the chloride concentration profiles obtained experimentally from control samples of an offshore platform after 25 years of service life. The platform is located 12 km off the coast of the Brazilian province Rio Grande do Norte, in the north-east of Brazil. The samples were extracted at different orientations and heights above mean sea level. A simple model based on Fick’s second law is considered and compared with a finite element model which takes into account transport of chloride ions by diffusion and convection. Results show that convective flows significantly affect the studied chloride penetrations. The convection velocity is obtained by fitting the finite element solution to the experimental data and seems to be directly proportional to the height above mean sea level and also seems to depend on the orientation of the face of the platform. This work shows that considering solely diffusion as transport mechanism does not allow a good prediction of the chloride profiles. Accounting for capillary suction due to moisture gradients permits a better interpretation of the material’s behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of the IRIS_2012 international benchmark, simulations were conducted to analyse impacts on reinforced concrete slabs by both rigid and deformable missiles. The analytical results were compared with physical tests conducted by the Technical Research Center VTT of Finland. In the impact discussed here, a rigid missile perforates the concrete slab. The missile is a thick steel tube filled with concrete with a total mass of 47.4 kg and strikes the target at 136 m/s. The target is a 250 mm thick, reinforced concrete slab that spans 2 m by 2 m and is held in a rigid supporting frame. Characterisation tests were provided for calibration of the parameters of the concrete models selected by the participants. Having reproduced those tests, the authors developed models for the slab and the missile. A damaged plasticity model was used for the concrete and the rebars were explicitly represented. The results obtained were very satisfactory in respect of the damage patterns caused in the concrete and the reinforcement; also, the calculated and measured values of the energy spent by the missile in perforating the slab differed by only 4%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology has been developed for characterising the mechanical behaviour of concrete, based on the damaged plasticity model, enriched with a user subroutine (V)USDFLD in order to capture better the ductility of the material under moderate confining pressures. The model has been applied in the context of the international benchmark IRIS_2012, organised by the OECD/NEA/CSNI Nuclear Energy Agency, dealing with impacts of rigid and deformable missiles against reinforced concrete targets. A slightly modified version of the concrete damaged plasticity model was used to represent the concrete. The simulation results matched very well the observations made during the actual tests. Particularly successful predictions involved the energy spent by the rigid missile in perforating the target, the crushed length of the deformable missile, the crushed and cracked areas of the concrete target, and the values of the strains recorded at a number of locations in the concrete slab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant number of short-to-mid height RC buildings with wide beams have been constructed in areas of moderate seismicity of Spain, mainly for housing and administrative use. The buildings have a framed structure with one-way slabs; the wide beams constitute the distinctive characteristic, their depth being equal to that of the rest of the slab, thus providing a flat lower surface, convenient for construction and the layout of facilities. Seismic behavior in the direction of the wide beams appears to be deficient because of: (i) low lateral strength, mainly because of the small effective depth of the beams, (ii) inherent low ductility of the wide beams, generated by high amount of reinforcement, (iii) the big strut compressive forces developed inside the column-beam connections due to the low height of the beams, and (iv) the fact that the wide beams are wider than the columns, meaning that the contribution of the outer zones to the resistance of the beam-column joints is unreliable because there is no torsion reinforcement. In the orthogonal direction, the behavior is worse since the only members of the slabs that contribute to the lateral resistance are the joists and the façade beams. Moreover, these buildings were designed with codes that did not include ductility requirements and required only a low lateral resistance; indeed, in many cases, seismic action was not considered at all. Consequently, the seismic capacity of these structures is not reliable. The objective of this research is to assess numerically this capability, whereas further research will aim to propose retrofit strategies. The research approach consists of: (i) selecting a number of 3-story and 6-story buildings that represent the vast majority of the existing ones and (ii) evaluating their vulnerability through three types of analyses, namely: code-type, push-over and nonlinear dynamic analysis. Given the low lateral resistance of the main frames, the cooperation of the masonry infill walls is accounted for; for each representative building, three wall densities are considered. The results of the analyses show that the buildings in question exhibit inadequate seismic behavior in most of the examined situations. In general, the relative performance is less deficient for Target Drift CP (Collapse Prevention) than for IO (Immediate Occupancy). Since these buildings are selected to be representative of the vast majority of buildings with wide beams that were constructed in Spain without accounting for any seismic consideration, our conclusions can be extrapolated to a broader scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows the preliminary results of the development and application of a procedure to filter the Acoustic Emission (AE) signals to distinguish between AE signals coming from friction and AE signals coming from concrete cracking. These signals were recorded during the trainings of an experiment carried out on a reinforced concrete frame subjected to dynamic loadings with the shaking table of the University of Granada (Spain). Discrimination between friction and cracking AE signals is the base to develop a successful procedure and damage index based on AE testing for health monitoring of RC structures subjected to earthquakes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of sulfate attack in concrete is considered vital for the preservation of the structural integrity of constructions. Its aggressive behaviour causes degradation of the cement matrix which changes the initial properties of the material. In this article, the sulfate resistance of concrete is studied. To that goal, four different concrete mixes were made with sulphur resistant cement. The concretes were tested for compressive strength, transport capacity of sulfates and microstructural properties. An experimental program was proposed in which the concrete samples were submerged in sodium sulphate (Na2SO4) solution. The obtained results were compared with reference values of concretes cured in calcium hydroxide [Ca(OH)2]. According to the results the concrete with ground granulated blast-furnace slag presented the best behavior when exposed to sodium sulphate (Na2SO4) solution. El estudio del ataque de sulfatos en el hormigón se considera de gran importancia para la conservación de la integridad estructural de las construcciones. Su agresividad se basa en la degradación de la matriz cementicia modificando las características iniciales de diseño. En el presente trabajo se estudia la resistencia del hormigón al ataque de sulfatos provenientes de sulfato sódico (Na2SO4). Para llevar a cabo la investigación se diseñaron cuatro dosificaciones de hormigón empleando cementos sulforresistentes y adiciones minerales. Se llevó a cabo una propuesta experimental donde las muestras de hormigón se sumergieron en disolución de sulfato sódico (Na2SO4) de concentración 1M. Posteriormente se realizaron ensayos de resistencia mecánica, capacidad de transporte de sulfatos y propiedades microestructurales, a distintas edades. Los resultados obtenidos se compararon con valores de referencia de mezclas de hormigón curadas expuestas a hi-dróxido cálcico [Ca(OH)2]. De acuerdo a los resultados obtenidos, el hormigón con escoria de alto horno presentó las mejores características de durabilidad frente a sulfatos provenientes de sulfato sódico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model for chloride transport in concrete is proposed. The model accounts for transport several transport mechanisms such as diffusion, advection, migration, etc. This work shows the chloride transport equations at the macroscopic scale in non-saturated concrete. The equations involve diffusion, migration, capillary suction, chloride combination and precipitation mechanisms. The material is assumed to be infinitely rigid, though the porosity can change under influence of chloride binding and precipitation. The involved microscopic and macroscopic properties of the materials are measured by standardized methods. The variables which must be imposed on the boundaries are temperature, relative humidity and chloride concentration. The output data of the model are the free, bound, precipitated and total chloride ion concentrations, as well as the pore solution content and the porosity. The proposed equations are solved by means of the finite element method (FEM) implemented in MATLAB (classical Galerkin formulation and the streamline upwind Petrov-Galerkin (SUPG) method to avoid spatial instabilities for advection dominated flows).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work studies the resistant of the concrete against magnesium sulfate (MgSO4) and compare the results with values obtained previously of the same concretes exposed to sodium sulfate (Na2SO4). Thus, it is possible analyze the influence of the cation type. To that end, four different concrete mixes were made with sulfur resistant cement and mineral admixtures (silica fume, fly ash and blast furnace slag). The concretes were submerged for different period in magnesium sulfate (MgSO4). After that, different tests were carried out to define mechanical and microstructural properties. The results obtained were compared with reference values of concretes cured in calcium hydroxide [Ca(OH)2]. According to the results, the concrete with blast furnace slag presented the best behavior front MgSO4, meanwhile the concretes with silica fume and fly ash were the most susceptible. The resistance of the concrete with blast furnace slag could be attributed to the characteristics of the hydrated silicates formed during the hydration time, which include aluminum in the chemical chain that hinder its chemical decomposition during the attack of magnesium. The magnesium sulfate solution was most aggressive than sodium sulfate solution. El presente trabajo estudia la resistencia de hormigones al ataque de sulfatos provenientes de sulfato magnésico (MgSO4) y compara estos valores con resultados previos de los mismos hormigones atacados con sulfato sódico (Na2SO4). De esta manera se estudia la interacción del catión que acompaña al ion sulfato durante su afectación a la matriz cementicia. Para lo anterior, se diseñaron cuatro dosificaciones empleando cementos sulforresistentes y adiciones minerales (humo de sílice, ceniza volante y escoria de alto horno). Los hormigones se sumergieron, por distintos periodos de tiempo, en disolución de sulfato magnésico (MgSO4) de concentración 1M, para después realizarles ensayos mecánicos y a nivel microestructural. Los valores obtenidos se compararon con los obtenidos en el hormigón de referencia curado en hidróxido cálcico. El hormigón con escoria de alto horno presentó el mejor comportamiento frente a MgSO4, siendo las mezclas de humo de sílice y ceniza volante las más susceptibles. La resistencia del hormigón con escoria se atribuye a las características de los silicatos hidratados formados durante la hidratación, los cuales incorporan aluminio en las cadenas impidiendo su descomposición ante un ataque por magnesio. El medio con sulfato magnésico mostro una mayor agresividad que el medio con sulfato sódico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cracking of reinforced concrete can occur in certain environments due to rebar corrosion. The oxide layer growing around the bars introduces a pressure which may be enough to lead to the fracture of concrete. To study such an effect, the results of accelerated corrosion tests and finite ele- ment simulations are combined in this work. In previous works, a numerical model for the expansive layer, called expansive joint element , was programmed by the authors to reproduce the effect of the oxide over the concrete. In that model, the expansion of the oxide layer in stress free conditions is simulated as an uniform expansion perpendicular to the steel surface. The cracking of concrete is simulated by means of finite elements with an embedded adaptable cohesive crack that follow the standard cohesive model. In the present work, further accelerated tests with imposed constant cur- rent have been carried out on the same type of specimens tested in previous works (with an embedded steel tube), while measuring, among other things, the main-crack mouth opening. Then, the tests have been numerically simulated using the expansive joint element and the tube as the corroding electrode (rather than a bar). As a result of the comparison of numerical and experimental results, both for the crack mouth opening and the crack pattern, new insight is gained into the behavior of the oxide layer. In particular, quantitative assessment of the oxide expansion relation is deduced from the ex- periments, and a narrower interval for the shear stiffness of the oxide layer is obtained, which could not be achieved using bars as the corroding element, because in that case the numerical results were insensitive to the shear stiffness of the oxide layer within many orders of magnitude