92 resultados para Cálculo variacional


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years a great number of high speed railway bridges have been constructed within the Spanish borders. Due to the demanding high speed trains route's geometrical requirements, bridges frequently show remarkable lengths. This fact is the main reason why railway bridges are overall longer than roadway bridges. In the same line, it is also worth highlighting the importance of high speed trains braking forces compared to vehicles. While vehicles braking forces can be tackled easily, the railway braking forces demand the existence of a fixed-point. It is generally located at abutments where the no-displacements requirement can be more easily achieved. In some other cases the fixed-point is placed in one of the interior columns. As a consequence of these bridges' length and the need of a fixed-point, temperature, creep and shrinkage strains lead to fairly significant deck displacements, which become greater with the distance to the fixed-point. These displacements need to be accommodated by the piers and bearings deformation. Regular elastomeric bearings are not able to allow such displacements and therefore are not suitable for this task. For this reason, the use of sliding PTFE POT bearings has been an extensive practice mainly because they permit sliding with low friction. This is not the only reason of the extensive use of these bearings to high-speed railways bridges. The value of the vertical loads at each bent is significantly higher than in roadway bridges. This is so mainly because the live loads due to trains traffic are much greater than vehicles. Thus, gravel rails foundation represents a non-negligible permanent load at all. All this together increases the value of vertical loads to be withstood. This high vertical load demand discards the use of conventional bearings for excessive compressions. The PTFE POT bearings' higher technology allows to accommodate this level of compression thanks to their design. The previously explained high-speed railway bridge configuration leads to a key fact regarding longitudinal horizontal loads (such as breaking forces) which is the transmission of these loads entirely to the fixed-point alone. Piers do not receive these longitudinal horizontal loads since PTFE POT bearings displayed are longitudinally free-sliding. This means that longitudinal horizontal actions on top of piers will not be forces but imposed displacements. This feature leads to the need to approach these piers design in a different manner that when piers are elastically linked to superstructure, which is the case of elastomeric bearings. In response to the previous, the main goal of this Thesis is to present a Design Method for columns displaying either longitudinally fixed POT bearings or longitudinally free PTFE POT bearings within bridges with fixed-point deck configuration, applicable to railway and road vehicles bridges. The method was developed with the intention to account for all major parameters that play a role in these columns behavior. The long process that has finally led to the method's formulation is rooted in the understanding of these column's behavior. All the assumptions made to elaborate the formulations contained in this method have been made in benefit of conservatives results. The singularity of the analysis of columns with this configuration is due to a combination of different aspects. One of the first steps of this work was to study they of these design aspects and understand the role each plays in the column's response. Among these aspects, special attention was dedicated to the column's own creep due to permanent actions such us rheological deck displacements, and also to the longitudinally guided PTFE POT bearings implications in the design of the column. The result of this study is the Design Method presented in this Thesis, that allows to work out a compliant vertical reinforcement distribution along the column. The design of horizontal reinforcement due to shear forces is not addressed in this Thesis. The method's formulations are meant to be applicable to the greatest number of cases, leaving to the engineer judgement many of the different parameters values. In this regard, this method is a helpful tool for a wide range of cases. The widespread use of European standards in the more recent years, in particular the so-called Eurocodes, has been one of the reasons why this Thesis has been developed in accordance with Eurocodes. Same trend has been followed for the bearings design implications, which are covered by the rather recent European code EN-1337. One of the most relevant aspects that this work has taken from the Eurocodes is the non-linear calculations security format. The biaxial bending simplified approach that shows the Design Method presented in this work also lies on Eurocodes recommendations. The columns under analysis are governed by a set of dimensionless parameters that are presented in this work. The identification of these parameters is a helpful for design purposes for two columns with identical dimensionless parameters may be designed together. The first group of these parameters have to do with the cross-sectional behavior, represented in the bending-curvature diagrams. A second group of parameters define the columns response. Thanks to this identification of the governing dimensionless parameters, it has been possible what has been named as Dimensionless Design Curves, which basically allows to obtain in a reduced time a preliminary vertical reinforcement column distribution. These curves are of little use nowadays, firstly because each family of curves refer to specific values of many different parameters and secondly because the use of computers allows for extremely quick and accurate calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente proyecto constituye una ampliación del proyecto final de carrera “Análisis del terremoto de Lorca 2011 mediante un Sistema de Información Geográfica” realizado en abril de 2013. Esta ampliación se centra en el estudio de la susceptibilidad del terreno a sufrir deslizamientos de laderas, con una aplicación en el municipio de Lorca, localizado en la Región de Murcia. Posteriormente, se realiza una comparativa entre los resultados de este estudio y los deslizamientos de ladera ocasionados por el terremoto de Lorca 2011. Para hacer el estudio de susceptibilidad, se ha partido del Sistema de Información Geográfica (SIG) diseñado en el proyecto anterior y se ha completado con más capas de información geográfica, referentes a la estimación de la susceptibilidad del terreno, como BCN25, mapa geotécnico, de ocupación del suelo... Todo proceso relacionado con la prevención y gestión de desastres naturales demanda la elaboración de una cartografía temática relativa a los aspectos a tratar. En este proyecto se detalla el proceso de producción de mapas de susceptibilidad del suelo a los deslizamientos usando como herramienta fundamental un SIG. Éste permite, en primer lugar, integrar, homogeneizar y analizar todas las variables que intervienen en el análisis de la susceptibilidad (pluviometría, características geotécnicas del suelo, altitud, pendiente...), en segundo lugar, integrar todos los factores intervinientes para obtener un mapa de susceptibilidad y, por último, incorporar los deslizamientos de ladera desencadenados por el terremoto de Lorca 2011 y compararlos con el mapa de susceptibilidad.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En el presente Trabajo Fin de Grado se modeliza la estructura del Pabellón de Gravimetría del Centro Astronómico de Yebes para así poder determinar su influencia sobre los valores de gravedad observados en el interior del Pabellón. El Pabellón de Gravimetría dispone en su interior de una sala dónde se realizan medidas de gravedad sobre siete pilares de hormigón situados a nivel del suelo. Para poder modelizar la sala de medida se ha realizado un levantamiento topográfico con las especificaciones técnicas de una escala 1:100. Tras la realización del levantamiento se han determinado las coordenadas geográficas del centro de los pilares de medida mediante el cálculo de una radiación, pues es necesario conocer éste dato al realizar medidas relativas de gravedad. Para el cálculo de la influencia que genera la estructura del Pabellón sobre las medidas de gravedad observadas en su interior se han creado una serie de programas en lenguaje Java empleando la fórmula de la atracción gravitatoria que genera un prisma (Nagy, 1969). Una vez se han llevado a cabo las observaciones y los cálculos necesarios se concluye que la influencia de la estructura sobre las medidas de la gravedad observadas en el interior del Pabellón no es de gran magnitud. No obstante esnecesario conocerla y así poder corregir los valores observados. Asimismo, se determina cierta desorientación de los pilares de medida con respecto al norte geográfico. El presente Trabajo Fin de Grado permitirá, entre otros, que el Centro de Desarrollos Tecnológicos de Yebes participe en proyectos de carácter internacional. Abstract: In the current Bachelor Thesis, the structure of the Pavellón de Gravimetría del Centro Astronómico de Yebes is moulded in order to determine its influence on the observed values of gravity inside the Pavilion. The Pabellón de Gravimetría holds in its interior a room where gravity measures are made on seven concrete pillars located on the ground level. In order to be able to mould the room, a topographical survey measurement was made on a 1:100 scale. After concluding the topographical survey measurement the geographical coordinates of the centre of the measurement pillars were determined, due to the necessity to know this data when making relative gravity measures. To calculate the influence that the pavilion structure has on the observed gravity measures in its interior generates, a series of programs in Java language have been created using the formula of the gravitational attraction that generates a prism (Nagy, 1969). Once the observations and the necessary calculations have been carried out, it is concluded that the influences of the structure of the Pavilion on the observed gravity measures inside it are not of a considerable magnitude. Despite that, it is necessary to know this to be able to correct the observed values. Also, certain disorientations of the pillars of measurement with respect to the geographical north is determined. The current Bachelor Thesis will allow, among others, the Centre of Technological Developments of Yebes to get involved in projects of international nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente se están utilizando supercomputadores para resolver problemas intensivos en cálculo tales como las previsiones meteorológicas, el aprendizaje de redes neuronales artificiales o incluso aplicaciones lúdicas como el ajedrez. El uso de esta tecnología queda limitado a las grandes corporaciones con medios financieros suficientes como para abordar la adquisición de tales ordenadores. La distribución del cálculo entre varios ordenadores es una solución más barata para aquellos casos en los que la aplicación es susceptible de ser distribuida. De hecho, es la única solución para muchas empresas que no pueden adquirir supercomputadores y que sin embargo soportan aplicaciones que precisan de mucha potencia de cálculo (por ejemplo, el análisis de imágenes). En este artículo mostraremos cómo utilizando un middelware, CORBA (Common Object Request Broker Architecture), y una implementación concreta de este, DST (Distributed Smalltalk), es posible distribuir una aplicación entre varios ordenadores de una manera elegante y escalable y cómo el trabajo cooperativo de varios ordenadores disminuye significativamente el tiempo total de cómputo. Creemos que esta forma de distribución puede solucionar muchos de los problemas de tiempos de ejecución con los que se enfrentan actualmente las empresas de desarrollo software

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dada la importancia de conocer la humedad del suelo de forma precisa y en tiempo real, se ha realizado este trabajo de investigación cuyo objetivo principal ha sido seleccionar un Balance Hídrico del Suelo (BHS) diario y validar sus estimaciones de humedad del suelo frente a medidas obtenidas “in situ”, aplicándolo a tres emplazamientos seleccionados en la zona centro con características edáficas y climáticas diferentes, y de este modo estimar con cierta precisión la humedad del suelo como Agua Disponible (AD) para las plantas y a su vez permitir la realización de estudios climáticos. Los observatorios meteorológicos seleccionados fueron: Guadalajara/El Serranillo en la zona aluvial del río Henares; Colmenar Viejo/Base Famet en la rampa sur del Guadarrama sobre rocas metamórficas; y Radiosondeo/Madrid(Barajas) en arenas arcósicas de grano grueso. Se realizó una caracterización morfológica y un estudio de las propiedades físicas, químicas e hidrofísicas de los suelos en cada emplazamiento. El suelo de Guadalajara, Xerorthent Típico presenta una secuencia genética de horizontes (Ap-AC-C1-C2) siendo su clase textural entre franco-arenosa a franca, con menos del 2% de elementos gruesos, presencia de caliza a lo largo de todo el perfil, destacando la homogeneidad en vertical y horizontal de sus propiedades. El suelo de Colmenar, Xerorthent Dystrico, presenta una secuencia genética de horizontes (A-C-C/R) apareciendo el horizonte C/R entre 20-30 cm; y la roca aproximadamente a unos 30 cm; destacando en este perfil su acidez y el alto contenido de elementos gruesos. El suelo de Radiosondeo, Haploxeralf Típico, presenta la secuencia normal de horizontes de los alfisoles (A-Bt1-Bt2-C/Bt); destacando su heterogeneidad principalmente en el plano horizontal, con presencia del Bt a diferentes profundidades en un corto espacio longitudinal. En una primera fase de experimentación (2007-2008) se seleccionaron BHS diarios que sólo utilizaban como datos de entrada la información de variables meteorológicas y el valor del Agua Disponible Total (ADT) para cada tipo de suelo y profundidad. Se probaron BHS diarios con agotamiento exponencial y directo de la reserva, utilizando la evapotranspiración de referencia de Penman-Monteith recomendada por FAO. Al mismo tiempo que se disponía de los datos estimados de humedad de suelo mediante diferentes BHS diarios en los tres emplazamientos, también se realizó una monitorización de la humedad del suelo “in situ” mediante el método gravimétrico, con adaptación de dicha metodología a la problemática de cada suelo, para determinar en cada fecha tanto la humedad del suelo como su contenido de AD para una profundidad de 0 a 30 cm. Se tomaron en cada fecha de muestreo 5 muestras para la profundidad 0- 10 cm, otras cinco para 10-20 cm y otras cinco para 20-30 cm, realizándose el correspondiente tratamiento estadístico de los datos. El ADT se calculó a partir de los datos de capacidad de campo y punto de marchitez obtenidos en laboratorio con membrana de Richards. Los resultados de esta primera fase permitieron conocer que el BHS exponencial diario era el que mejor estimaba el AD en Guadalajara considerando la capacidad de campo a una presión de 33 kPa, mientras que en Colmenar se debían considerar para un mejor ajuste, 10 kPa en lugar de 33 kPa. En el observatorio de Radiosondeo debido a que en cada fecha de muestreo la profundidad en la que aparecía el horizonte Bt era diferente, no se pudo demostrar si el BHS exponencial diario tenía un buen comportamiento. En una segunda fase de experimentación (2009-2012) y con el objeto de aminorar los problemas encontrados en Radiosondeo para la medida de humedad del suelo por el método gravimétrico, se procedió a la instalación y utilización de diferentes sensores de medida de humedad de suelo en el mismo observatorio: TDR (time domain reflectometry - TRIME T3 de IMKO); FDR capacitivo (frecuency domain reflectometry - ECH2O EC-20 de DECAGON) y otros. Esta segunda fase de experimentación tuvo una duración de 4 años y se compararon las medidas de humedad de suelo obtenidas a partir de los sensores con las estimadas del BHS exponencial hasta una profundidad de 0 a 85 cm. En laboratorio se realizaron calibraciones específicas de los sensores TDR y FDR para cada uno de los horizontes más diferenciados del Haploxeralf Típico, utilizando diferentes tipos de regresión. Los valores de humedad de suelo con el equipo TDR, corregidos mediante la calibración específica de laboratorio, fueron los que más se ajustaron a las medidas realizadas por método gravimétrico “in situ”, por lo que se utilizó el TDR para las comparaciones con los valores obtenidos del BHS exponencial diario durante los cuatro años de esta segunda fase experimental. Se realizaron diferentes estimaciones del ADT, partiendo de datos de laboratorio y/o de datos procedentes de humedad de los sensores en campo. Los resultados mostraron de nuevo la conveniencia de utilizar el BHS exponencial diario, pero en este caso, con la estimación del ADT realizada a partir de las gráficas de los sensores. Mediante la utilización de los datos de humedad del BHS exponencial diario se han realizado comparaciones con el mismo tipo de balance pero utilizando un periodo semanal o mensual en lugar de diario, para conocer las diferencias. Los valores obtenidos con periodicidad mensual han dado valores de AD inferiores a los balances calculados semanalmente o diariamente. Por último se ha comprobado que los resultados de un BHS exponencial diario pueden complementar la información que se obtiene del Índice de Precipitación Estandarizado (SPI) y pueden mejorar el estudio de la sequía agrícola. ABSTRACT Due to the importance of a better knowledge of soil water at real time and in a more precisely way, this research work has being carried out with the main objective of selecting a daily Soil Water Balance (SWB) to estimate soil water content, and validate it in comparison to “in situ” measurements. Three locations, differing in soil and climate characteristics, were selected in central Spain in order to estimate with certain acuity soil water as plant-Available Water (AW) and to serve as a tool for the climatic studies. The selected places near meteorology stations were: Guadalajara/El Serranillo an alluvium of the Henares watershed; Colmenar Viejo/Base Famet, in the south raised area of the Guadarrama river basin, over metamorphic rocks; and Radiosondeo/Madrid (Barajas) in coarse arkosic sandstone. Morphology characterization, physical, chemical and hydrologic soil properties were studied in each area. In Guadalajara the soil is a Typic Xerorthent with a (Ap-AC-C1- C2) genetic horizon sequence, loam-sandy to loam textural class, less than 2% of rock fragments, presence of equivalent CaCO3 through the whole profile, outstanding the vertical and horizontal homogeneity of the properties. In Colmenar the soil is represented by a Dystric Xerorthent with a (A-C-C/R) genetic horizon sequence, the C/R is 20-30 cm deep where rock outcrops are approximately at 30 cm; a characteristic feature of this profile is its high acidity and high rock fragments content. In Radiosondeo the soil is represented by a Typic Haploxeralf, with the usual alfisol genetic horizon sequence (A-Bt1-Bt2-C/Bt); outstanding its horizontal heterogeneity, “the variability of the Bt (clay enriched horizon) depth in short distances”. In a first experimental stage (2007-2008), the daily SWB chosen was that which only uses as input data the information from the meteorology variables and plant-Total Available Water (TAW) for each soil type and depth. Different daily SWB (with exponential or direct plant-Available Water depletion) were applied, using the Penman- Monteith reference evapotranspiration (ETo) recommended by FAO. At the same time as soil water content was estimated from the different daily SWB at the three locations, also soil water content was being monitored by “in situ” gravimetric methodology, adapting it to each soil characteristic, to determine every time soil water content and AW to a depth of 0 to 30 cm. In each sampling date, 5 samples for each depth were taken: 0-10 cm; 10-20 cm and 20-30 cm and the data were submitted to the corresponding statistical analysis. The TAW was calculated based on field capacity (FC) and permanent wilting point (PWP) data obtained from laboratory by the Richards pressure plate. Results from this first experimental stage show that the daily exponential SWB was the one which better estimated the AW in Guadalajara considering field capacity at -33 kPa, though in Colmenar, field capacity at -10 kPa must be considered instead of -33 kPa for a better estimation. In Radiosondeo due to the fact that the Bt horizon depth varied in different sampling dates, it could not be established if the daily exponential SWB had a good performance. In a second experimental stage (20019-2012) and with the objective of minimizing the problems encountered in Radiosondeo for measuring “in situ” soil water content by the gravimetric method, the installation of different sensors for measuring soil water content were established and used in the same field location: TDR (time domain reflectometry - TRIME T3 from IMKO), capacitance FDR (frecuency domain reflectometry - ECH2O EC-20 from DECAGON) and others. This second experimental stage lasted 4 years in order to compare the soil water measures from the sensors with the estimations by the exponential SWB form 0 to 85 cm soil depths. At laboratory, specific calibrations for TDR and FDR sensors of the Typic Haploxeralf more differentiated horizons were done using different types of regressions. The results showed that soil water data obtained by the TDR equipment, corrected by the specific laboratory calibration, best fitted to “in situ” gravimetric soil water measures. In this way TDR was used for comparing to the daily exponential SWB during the four years of this second experimentation stage. Various estimations for obtaining TAW were tested; based on laboratory data – and/or on the data obtained of the soil water content field sensors. Results confirmed again, the convenience of using the daily exponential SWB, though in this case, with the TAW obtained from the field sensors graphics. Soil water estimated by exponential SWB on daily basis was compared to weekly and monthly periods, in order to know their reliability. The results obtained for a monthly period gave less AW than the ones obtained in a weekly or daily period. Finally it has been proved that the results obtained from the exponential SWB in a daily bases can be used as a useful tool in order to give complementary information to the SPI (Precipitation Standardized Index) and to help in agricultural drought studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta memoria pretende ilustrar el desarrollo del Proyecto de Fin de Carrera Uso del cálculo numérico CFD para el estudio de actuaciones de una motocicleta de competición de los alumnos Álvaro Ramos Cenzano y Mauro Botella Mompó. Se centra en el estudio de las fuerzas aerodinámicas ejercidas sobre una motocicleta de competición, en concreto de una Moto2 del campeonato de España de velocidad (CEV), por medio de programas de simulación. Los capítulos del 1 al 4, describen por qué surgió el Proyecto, los datos a tener en cuenta del reglamento oficial de Moto2 del CEV (centrándonos sobre todo en los aspectos que afectan a la Aerodinámica, como puede ser el carenado), y los objetivos que se pretenden hallar con este proyecto. Se hará una pequeña introducción a la aerodinámica general para después profundizar en la aerodinámica automovilística y sobretodo en la de las motocicletas. Pasando por el interés que tiene la aerodinámica a diferentes niveles (comercial y de competición), y su evolución a lo largo de la historia. Se analizarán los diferentes métodos de trabajo que se podrían usar para el estudio aerodinámico, centrándose sobre todo en la técnica de estudio informático por Dinámica de Fluidos Computacional o CFD. Dado que el proyecto está basado en unas motocicletas reales, surgirán una serie de problemas en el uso de los métodos numéricos que se irán solventando, intentando mantener la estructura lo más fiel posible a los modelos reales. Todos estos problemas y sus soluciones se detallarán con la intención de que puedan servir de ayuda para futuros estudios. Tras las simulaciones con los programas CFD correspondientes a los distintos modelos de motocicleta, se compararán los resultados para ayudar en la definición del modelo final. El proyecto concluirá con las conclusiones obtenidas por los alumnos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La Norma UNE 68050:1998, publicada hace casi tres años, sustituye a la antigua Norma UNE de 1986. Al igual que ésta, la actual es equivalente a la Norma Internacional ISO 5707:1996 y viene a cubrir las necesidades que las nuevas instalaciones de ordeño, más grandes, con más elementos y con mayor consumo, estaban demandando. El nuevo procedimiento de cálculo se complica enormemente, al incorporar parámetro y variables no considerados anteriormente. Así, para el cálculo del diámetro de la conducción de leche se tiene en cuenta el número de unidades, el intervalo de colocación de las mismas, la pendiente con la que se instala, el flujo máximo de leche de las vacas, la forma de montaje, su longitud y las entradas intermitentes de aire. En el caso de la determinación del caudal de la bomba, el cálculo de las necesidades de aire para el lavado de la instalación es una novedad de la Norma, así como la consideración del consumo de los elementos auxiliares y una nueva fórmula para calcular la reserva real de la instalación. Finalmente, el diámetro interior de las conducciones de vacío se calcula en función de la longitud de las mismas, del material con que están fabricadas, la caída de vacío prevista y el caudal de aire que circula por ellas. Sin olvidar que se consideran las pérdidas de vacío que pueden provocar los codos de la tubería, las piezas especiales u otros recipientes de la instalación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la Web 2.0, donde usuarios finales sin grandes conocimientos de programación pueden interactuar y crear aplicaciones web utilizando componentes publicados en Internet, ofrecidos por una gran variedad de proveedores de servicio. La selección de estos componentes requiere de un análisis exhaustivo por parte de los usuarios sobre las propiedades de estos componentes en referencia a su calidad. En este proyecto, se presentan dos modelos de calidad según una estructura jerárquica, uno para componentes web como elementos autónomos y otro para componentes utilizados en aplicaciones de mashup, basado en un análisis de la emergente Web 2.0. Además, se define una herramienta de medición y anotación de calidad para los distintos niveles de los modelos. Estas herramientas pretenden ser un útil instrumento para los desarrolladores y usuarios de componentes y mashups.---ABSTRACT---In the Web 2.0, where end users without a technical programming background can interact and develop web applications leveraging web components published on the Internet, offered by a great diversity of service providers. This component selection requires an exhaustive analysis by these end users based on the requirements of these components related to their quality. In this work, two quality models are presented according to a hierarchical structure, one for web components as independent elements and another one for web components as parts of web mashup applications, based on an analysis of the emerging Web 2.0. In addition, a measuring and write down quality framework is defined to weigh the quality of all the levels of the models. These tools intend to provide a useful instrument to components and mashup developers and end users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigación experimental sobre pilares de hormigón reforzados con FRP. El confinamiento con un encamisado de FRP se ha convertido en un método habitual de refuerzo de pilares de hormigón armado en estructuras existentes como puentes o edificios. Numerosos estudios experimentales han demostrado que se trata de un modo eficaz de incrementar considerablemente la resistencia del hormigón. En los últimos años se están proponiendo también diferentes modelos teóricos y se han publicado en diversos países guías y recomendaciones con diversas ecuaciones para el cálculo. En este trabajo se revisan las formulaciones propuestas en las principales recomendaciones publicadas incidiendo en los dos aspectos que se han identificado como claves en el comportamiento del hormigón confinado con FRP: la deformación última efectiva del FRP y la influencia de la forma de la sección del pilar en la eficacia del confinamiento

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As mudanças climáticas exacerbadas pela liberação antropogênica de gases de efeito estufa, aliadas ao aumento da demanda energética, colocam em destaque a necessidade de reduzir o consumo energético como uma das prioridades da sustentabilidade. Da energia elétrica consumida no Brasil, 45% destina-se a proporcionar conforto ambiental para seus usuários, na operação e manutenção das edificações (BRASIL, 2012). A eficiência energética na edificação é uma das prioridades para conseguir um entorno sustentável, garantindo assim o nível de conforto requerido pelos usuários com um uso razoável de recursos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En esta obra, se presenta un análisis estructural de tableros de puentes de sección constante y simplemente apoyados, compuestos de vigas y losas arbitrariamente conectadas. El estudio se realiza para el caso general de carga vertical puntual actuando en un punto genérico del tablero. Se determinan las matrices de rigidez de las vigas y losas, considerando en estas últimas sus dos tipos de esfuerzos, es decir, los esfuerzos laja y placa. En la deducción de la matriz de rigidez de todo el tablero, se utiliza la técnica estándar de la teoría de los métodos matriciales en el cálculo de estructuras. El método de la matriz de transferencia y uno iterativo, análogo al método de H. Cross para entramados planos, son también expuestos. Se resuelve, finalmente, un ejemplo de aplicación mediante un ordenador electrónico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo de este proyecto se centra en la definición, diseño y cálculo de las principales instalaciones eléctricas de la isla de generación, típicas de una central de ciclo combinado en configuración mono-eje. Se procederá a la definición de la arquitectura del sistema de distribución eléctrica de la planta definiendo los equipos eléctricos necesarios para la alimentación y protección de los servicios auxiliares de la isla de potencia y estableciendo una filosofía basada en la optimización del dimensionamiento de los distintos componentes del sistema. El diseño de los componentes eléctricos de la planta se hará en base a los más estrictos estándares internacionales con los que se garantiza el cumplimiento de las condiciones de seguridad, tanto de las personas como la de los propios equipos, fiabilidad y funcionalidad. El siguiente paso consistirá en adaptar los equipos definidos a los existentes en el mercado y así, evitar los sobrecostes que conlleva la adquisición de equipos no estandarizados en el mercado. Abstract The main objective of the project is the definition, analysis and sizing of the main components of the electrical system of a combined cycle power plant. This includes generation, auxiliary services and emergency systems. The design is intended to meet the International Electrotechnical Commission´s standards. These will ensure the adequate and safe operation, taking into account all operation conditions of the plant and the mechanical calculation of the thermal balance by the sizing of main mechanical equipment. An acceptable level of safety and health of workers and equipment is a mandatory requirement. The final results obtained are equipment that are able to achieve the highest level of protection for workers, assets and environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este articulo se presenta el diseño y calculo de cimentaciones para torres de comunicación, que pueden ser extendidos en general a elementos muy solicitados a carga transversal (típicamente el viento) y con poca carga vertical (soportando generalmente elementos ligeros y siendo predominante el propio peso de la cimentación). El principal objeto de la ponencia es analizar el método de cálculo riguroso de las cimentaciones tipo pozo, sus hipótesis aplicables y limitaciones, presentando una metodología de cálculo e incluyendo las comprobaciones a realizar. El cálculo de este tipo de cimentaciones en la práctica profesional suele basarse en métodos semiempíricos o tablas, empleando en ocasiones el método de Sulzberger sin discriminar sobre su aplicabilidad, sin emplear los debidos ensayos y parámetros geotécnicos y sin realizar todas las comprobaciones necesarias. Se realiza también el cálculo de dimensionamiento de cimentación de un caso real, mostrando el desarrollo matemático de la formulación aplicada y realizando todas las comprobaciones de estabilidad, geotécnicas y estructurales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objeto de esta publicación es presentar un método para el cálculo de presas bóveda. El método consta de las siguientes partes fundamentalmente: 1) Sustitución de la estructura continua por una estructura entramado espacial formada por nudos (sobre la superficie media) y barras rectas. 2) Determinación de las características mecánicas de las barras. 3) Aplicación de las cargas en los nudos. 4) Cálculo del entramado espacial por procedimientos matriciales (método de equilibrio o matriz de rigidez). Presenta la ventaja de utilizar programas estándar de cálculo de estructuras(STRESS, BAUSTATIK, etc.) de donde resulta una gran economía. Es aconsejable realizar programas adicionales sencillos para entrada de datos del emparrillado y obtención de resultados en tensiones y tensiones principales. Finalmente se comparan los resultados obtenidos con el método en las presas tipos 1 y 5 de CIRIA con otros métodos de cálculo de presas bóveda

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Una de las principales preocupaciones a la hora de realizar cualquier proyecto de ingeniería es la adecuada determinación de los hidrogramas de avenida de los cursos de agua que lo afecten. Hoy en día es posible la simulación de modelos hidrológicos complejos de lluvia directa sobre malla 2D de elementos finitos, empleando los avances en cálculo vectorial que ofrece la tecnología CUDA (Arquitectura Unificada de Dispositivos de Cálculo), sin la necesidad de determinar subcuencas y tránsitos (como en HEC-HMS). Con los datos que ofrecen los Modelos Digitales del Terreno GRID del PNOA español (Plan Nacional de Ortofotografía Aérea) con precisión de 5 x 5 m y las Coberturas del Terreno SIG CORINE (Coordinación de Información del Medio Ambiente), que permite la evaluación de la rugosidad del suelo, se tiene la información necesaria para construir fácilmente este tipo de modelos. En este documento se presenta un procedimiento para delimitar fácilmente los cursos de agua principales y disponer en estas zonas un tamaño más pequeño de los elementos de la malla. El método propuesto permite una mejor definición de estas áreas después de unas pocas iteraciones, acelerando por tanto el proceso de construcción del modelo sin comprometer la calidad de los resultados. Para demostrar el método, se modelizaron dos cuencas completas mediante lluvia directa sobre una malla de elementos 2D. Se ensayaron diferentes niveles de precisión (variando el número de elementos) y se incluyeron dos presas, usando los datos del Modelo Digital del Terreno del PNOA. También se completó el cálculo hidrológico de ambas mediante HEC-HMS. En primer lugar se estudió la cuenca del río Zapardiel (cuenca del Duero, con superficie total de 1.450 km2, no presenta regulación artificial, pero sí algunas áreas de almacenamiento naturales). La segunda cuenca ensayada correspondió al río Zújar (cuenca del Guadiana, con superficie total de 8.500 km2, que incluye dos grandes presas: La Serena, con una capacidad de 3.200 hm3 y el Embalse del Zújar, situado aguas abajo de la primera, con un volumen útil de 300 hm3). Los resultados confirmaron que la forma de modelizar clásica con enfoque de subcuencas y tránsitos (tipo HEC-HMS) puede ser reemplazada por simulaciones de lluvia directa sobre malla 2D, por lo tanto reduciendo la incertidumbre inherente en la estimación de tiempos de concentración de subcuencas y parámetros de tránsito. Gracias a la disponibilidad de datos públicos de GRID PNOA y cobertura del terreno CORINE, actualmente es posible construir modelos de mallas de elementos 2D para simular lluvia directa sobre cuenca sin necesidad de costosos levantamientos topográficos. Con el hardware disponible hoy en día en ordenadores de uso general, se puede establecer un límite superior razonable para mallas 2D de 4 millones de elementos, lo que permite la correcta simulación de la lluvia directa en cuencas de hasta 10.000 km2. Para cuencas más grandes, este proceso se podría aplicar de forma repetida a varias zonas más pequeñas o en sucesivas secciones de la cuenca.