52 resultados para experimental modal analysis
Resumo:
Different methods to reduce the high suction caused by conical vortices have been reported in the literature: vertical parapets, either solid or porous, placed at the roof edges being the most analysed configuration. Another method for alleviating the high suction peaks due to conical vortices is the use of some non-standard parapet configuration like cantilever parapets. In this paper the influence of roof curvature on the conical vortex pattern appearing on a curved roof (Fig. 1) when subject to oblique winds is experimentally analysed by testing the mean pressure distribution on the curved roofs of low-rise building models in a wind tunnel. Also, the efficiency of cantilever parapets to reduce mean suction loads on curved roofs is experimentally checked. Very high suction loads have been measured on curved roofs, the magnitude of these high suction loads being significantly decreased when cantilever parapets are used. Thus, the suitability of these parapets to reduce wind pressure loads on curved roofs is demonstrated.
Resumo:
The phenomenon of self-induced vibrations of prismatic beams in a cross-flow has been studied for decades, but it is still of great interest due to their important effects in many different industrial applications. This paper presents the experimental study developed on a prismatic beam with H-section.The aim of this analysis is to add some additional insight into the behaviour of the flow around this type of bodies, in order to reduce galloping and even to avoid it. The influence of some relevant geometrical parameters that define the H-section on the translational galloping behaviour of these beams has been analysed. Wind loads coefficients have been measured through static wind tunnel tests and the Den Hartog criterion applied to elucidate the influence of geometrical parameters on the galloping properties of the bodies under consideration.These results have been completed with surface pressure distribution measurements and, besides, dynamic tests have been also performed to verify the static criterion. Finally, the morphology of the flow past the tested bodies has been visualised by using smoke visualization techniques. Since the rectangular section beam is a limiting case of the H-section configuration, the results here obtained are compared with the ones published in the literature concerning rectangular configurations; the agreement is satisfactory.
Resumo:
This article reviews all the experimental tests carried out to analyze the performance of a FluidReflex photovoltaic concentrator. This novel concentrator concept consists of a single reflective stage immersed in an optical fluid. The presence of the fluid entails significant advantages. It not only allows a high system optical efficiency and increases the attainable concentration but also enhances the heat dissipation from the cell. In addition, the electrical insulation is improved, and the problem of water vapor condensation inside the module is avoided. A complete characterization is addressed in this paper. Among the experimental results, a measured optical efficiency of 83.5% for a concentration of 1035× stands out
Resumo:
Es conocido que la variación del comportamiento dinámico de las estructuras puede ser empleado dentro de un sistema de monitorización de su integridad estructural. Así, este estudio tiene como objetivo comprender el comportamiento dinámico de edificios esbeltos, frente a diferentes agentes ambientales como la temperatura y/o dirección y velocidad del viento. En el marco de esta investigación, se estudian dos edificios: la Torre de la ETSI (Escuela Técnica Superior de Ingenieros) de Caminos, Canales y Puertos de la UPM (Universidad Politécnica de Madrid) y un edificio de viviendas situado en la calle de Arturo Soria de Madrid. Los datos medioambientales antes mencionados, se registraron con sendas estacionales meteorológicas situadas en las azoteas de ambos edificios. Se realiza el análisis modal operacional de ambas estructuras. Este análisis se realiza a partir de las mediciones de las aceleraciones ante excitaciones ambientales, es un análisis basado sólo en la respuesta de la estructura. Por tanto, no es necesario interrumpir el funcionamiento en servicio de la instalación, obteniendo su comportamientos en este estado. A partir de este análisis, se obtienen las frecuencias naturales, los amortiguamientos modales y las formas modales. Así, en este trabajo se ha estudiado la relación existente entre la variación en la estimación de las frecuencias naturales y la variación de los agentes ambientales (fundamentalmente la temperatura). Los ensayos dinámicos en los dos edificios mencionados anteriormente, se han realizado utilizando acelerómetros de alta sensibilidad sincronizados inalámbricamente, lo cual ha simplificado el trabajo experimental si lo comparamos con los sistemas tradicionales. Como resultado del trabajo realizado se pueden destacar los siguientes puntos: (i) se ha visto que con el equipamiento disponible se pueden realizar análisis dinámicos de edificios, (ii) se ha mejorado el conocimiento dinámico de estas estructuras, y (iii) se ha visto la importancia que pueden tener los agentes ambientales dependiendo por un lado del tipo estructura del edificio. A partir del trabajo, se podrían actualizar modelos matemáticos que sirvan para la predicción de daños en las estructuras, y por otro, se podrán eliminar los efectos de los agentes ambientales, lo cual es un punto vital si se quiere emplear los parámetros modales para el cálculo de indices de daño. La aplicación de este tipo de investigación ayudará a tener una información mayor sobre el comportamiento de las estructuras y así, en el futuro, poder realizar distintos tipos de procesos, como la formulación de modelos matemáticos que reflejen con mayor fidelidad el comportamiento real. De esta forma, la monitorización de los agentes medioambientales permitirán valorar la influencia de estas variaciones sobre la estructura pudiéndose eliminar estos efectos. Con ello, se mejora la incertidumbre en la variación de frecuencias que puede ser utilizada como un sistema de activación de alarmas frente a la detección de daños estructurales. It is known that the variation of the dynamic behavior of structures can be used within a system to monitor structural integrity. So, this study aims to understand the dynamic behavior of slender buildings, against different environmental agents such as temperature and / or wind direction and velocity. As part of this investigation, two buildings are studied: the ETSI's (Escuela Técnica Superior de Ingenieros) main tower of Escuela de Caminos, Canales y Puertos of UPM (Universidad Politécnica de Madrid) and a residential building located in the streets Arturo Soria Madrid. The environmental data were recorded with weather stations located on the roof of both buildings. In both structures a modal operational analysis has been carried out. This analysis is performed from the measurements of the acceleration to the environmental excitation, this analysis is based only on the response of the structure. Therefore, it is not necessary to interrupt the operation of the structure, getting its behavior in this state. From this analysis, the natural frequencies, modal damping and mode shapes are obtained. So, in this work we have studied the existing relationship between the variation in the estimate of the natural frequencies and the variation of environmental agents (mainly temperature). The dynamic tests in the two buildings mentioned above, have been made using high-sensitivity accelerometers wirelessly synchronized, which has simplified the experimental work when compared to traditional systems. As a result of work performed can highlight the following points: (i) it has been found that with the available equipment can perform dynamic analysis of buildings, (ii) has improved dynamic knowledge of these structures, and, (iii) can be seen the potential importance of environmental agents depending on the type of building structure. From the work, mathematical models can be updated that serve to prediction of damage to structures, and on the other side, may eliminate the effects of environmental agents, which is a vital point if you want to use the modal parameters for calculating damage ratings. The application of this type of research will help to have more information about the behavior of structures and so, in the future, conduct various processes, as the formulation of mathematical models that reflect more accurately an actual behavior. In this way the monitoring of environmental agents will allow evaluate the influence of these variations on the structure being possible eliminate these effects. Thereby, improvement the uncertainty in the frequencies variation that can be used as an alarm activation system from detection of structural damage.
Resumo:
A validation of the burn-up simulation system EVOLCODE 2.0 is presented here, involving the experimental measurement of U and Pu isotopes and some fission fragments production ratios after a burn-up of around 30 GWd/tU in a Pressurized Light Water Reactor (PWR). This work provides an in-depth analysis of the validation results, including the possible sources of the uncertainties. An uncertainty analysis based on the sensitivity methodology has been also performed, providing the uncertainties in the isotopic content propagated from the cross sections uncertainties. An improvement of the classical Sensitivity/ Uncertainty (S/U) model has been developed to take into account the implicit dependence of the neutron flux normalization, that is, the effect of the constant power of the reactor. The improved S/U methodology, neglected in this kind of studies, has proven to be an important contribution to the explanation of some simulation-experiment discrepancies for which, in general, the cross section uncertainties are, for the most relevant actinides, an important contributor to the simulation uncertainties, of the same order of magnitude and sometimes even larger than the experimental uncertainties and the experiment- simulation differences. Additionally, some hints for the improvement of the JEFF3.1.1 fission yield library and for the correction of some errata in the experimental data are presented.
Resumo:
Current worldwide building legislation requirements aim to the design and construction of technical services that reduce energy consumption and improve indoor hygrothermal conditions. The retail sector in Spain, with a lot of outdated technical systems, demands energy conservation measures in order to reduce the increasingly electrical consumption for cooling. Climatic separation with modern air curtains and advanced hygrothermal control systems enables energy savings and can keep suitable indoor air temperature and humidity of stores with intense pedestrian traffic, especially when located in hot humid climates. As stated in the article, the energy savings in commercial buildings with these systems exceeds 30%
Resumo:
In this paper experimental results related to both stability an the dynamic of a asiximmetric liquid bridge between unequal disk are presented. Experiments have been performed by using a drop tower facility and the response of the liquid bridge to a sudden change of the acceleration level acting on it has bee obtained.