64 resultados para Thermal optical efficiency
Resumo:
Non-uniform irradiance patterns created by Concentrated Photovoltaics (CPV) concentrators over Multi-Junction Cells (MJC) can originate significant power losses, especially when there are different spectral irradiance distributions over the different MJC junctions. This fact has an increased importance considering the recent advances in 4 and 5 junction cells. The spectral irradiance distributions are especially affected with thermal effects on Silicone-on-Glass (SoG) CPV systems. This work presents a new CPV optical design, the 9-fold Fresnel Köhler concentrator, prepared to overcome these effects at high concentrations while maintaining a large acceptance angle, paving the way for a future generation of high efficiency CPV systems of 4 and 5 junction cells.
Resumo:
Non-uniform irradiance patterns created by Concentrated Photovoltaics (CPV) concentrators over Multi-Junction Cells (MJC) can originate significant power losses, especially when there are different spectral irradiance distributions over the different MJC junctions. This fact has an increased importance considering the recent advances in 4 and 5 junction cells. This work presents a new CPV optical design, the 9-fold Fresnel Köhler concentrator, prepared to overcome these effects at high concentrations while maintaining a large acceptance angle, paving the way for a future generation of high efficiency CPV systems of 4 and 5 junction cells.
Resumo:
Recent advances in coherent optical receivers is reviewed. Digital-Signal-Processing (DSP) based phase and polarization management techniques make coherent detection robust and feasible. With coherent detection, the complex field of the received optical signal is fully recovered, allowing compensation of linear and nonlinear optical impairments including chromatic dispersion (CD) and polarization-mode dispersion (PMD) using digital filters. Coherent detection and advanced optical modulation formats have become a key ingredient to the design of modern dense wavelength-division multiplexed (DWDM) optical broadband networks. In this paper, firstly we present the different subsystems of a digital coherent optical receiver, and secondly, we will compare the performance of some multi-level and multi-dimensional modulation formats in some physical impairments and in high spectral-efficiency (SE) and high-capacity DWDM transmissions, simulating the DSP with Matlab and the optical network performance with OptiSystem software.
Resumo:
Linear Fresnel collectors still present a large margin to improve efficiency. Solar fields of this kind installed until current time, both prototypes and commercial plants, are designed with widths and shifts of mirrors that are constant across the solar field. However, the physical processes that limit the width of the mirrors depend on their relative locations to the receiver; the same applies to shading and blocking effects, that oblige to have a minimum shift between mirrors. In this work such phenomena are studied analytically in order to obtain a coherent design, able to improve the efficiency with no increase in cost. A ray tracing simulation along one year has been carried out for a given design, obtaining a moderate increase in radiation collecting efficiency in comparison to conventional designs. Moreover, this analytic theory can guide future designs aiming at fully optimizing linear Fresnel collectors' performance.
Resumo:
A complete characterisation of PV modules for building integration is needed in order to know their influence on the building’s global energy balance. Specifically, certain characteristic parameters should be obtained for each different PV module suitable for building integrated photovoltaics (BIPV), some by direct or indirect measurements at the laboratory, and others by monitoring the element performance mounted in real operating conditions. In the case of transparent building envelopes it is particularly important to perform an optical and thermal characterization of the PV modules that would be integrated in them. This paper addresses the optical characterization of some commercial thin-film PV modules having different degrees of transparency, suitable for building integration in façades. The approach is based on the measurement of the spectral UV/Vis/NIR reflectance and transmittance of the different considered samples, both at normal incidence and as a function of the angle of incidence. With the obtained results, the total and zoned UV, visible and NIR transmission and reflection values are calculated, enabling the correct characterization of the PV modules integrated in façades and the subsequent evaluation of their impact over the electrical, thermal and lighting performance in a building.
Resumo:
This paper reports on a case study of the impact of fabrication steps on InN material properties. We discuss the influence of annealing time and sequence of device processing steps. Photoluminescence (PL), surface morphology and electrical transport (electrical resistivity and low frequency noise) properties have been studied as responses to the adopted fabrication steps. Surface morphology has a strong correlation with annealing times, while sequences of fabrication steps do not appear to be influential. In contrast, the optical and electrical properties demonstrate correlation with both etching and thermal annealing. For all the studied samples PL peaks were in the vicinity of 0.7 eV, but the intensity and full width at half maximum (FWHM) demonstrate a dependence on the technological steps followed. Sheet resistance and electrical resistivity seem to be lower in the case of high defect introduction due to both etching and thermal treatments. The same effect is revealed through 1/f noise level measurements. A reduction of electrical resistivity is connected to an increase in 1/f noise level.
Resumo:
Spotlighting is one illumination field where the application of light emitting diodes (LED) creates many advantages. Commonly, the system for spot lights consists of a LED light engine and collimating secondary optics. Through angular or spatial separated emitted light from the source and imaging optical elements, a non uniform far field appears with colored rings, dots or patterns. Many feasible combinations result in very different spatial color distributions. Several combinations of three multi-chip light sources and secondary optical elements like reflectors and TIR lenses with additional facets or scattering elements were analyzed mainly regarding the color uniformity. They are assessed by the merit function Usl which was derived from human factor experiments and describes the color uniformity based on the visual perception of humans. Furthermore, the optical systems are compared concerning efficiency, peak candela and aspect ratio. Both types of optics differ in the relation between the color uniformity level and other properties. A plain reflector with a slightly color mixing light source performs adequate. The results for the TIR lenses indicate that they need additional elements for good color mixing or blended light source. The most convenient system depends on the requirements of the application.
Resumo:
Adjusting N fertilizer application to crop requirements is a key issue to improve fertilizer efficiency, reducing unnecessary input costs to farmers and N environmental impact. Among the multiple soil and crop tests developed, optical sensors that detect crop N nutritional status may have a large potential to adjust N fertilizer recommendation (Samborski et al. 2009). Optical readings are rapid to take and non-destructive, they can be efficiently processed and combined to obtain indexes or indicators of crop status. However, other physiological stress conditions may interfere with the readings and detection of the best crop nutritional status indicators is not always and easy task. Comparison of different equipments and technologies might help to identify strengths and weakness of the application of optical sensors for N fertilizer recommendation. The aim of this study was to evaluate the potential of various ground-level optical sensors and narrow-band indices obtained from airborne hyperspectral images as tools for maize N fertilizer recommendations. Specific objectives were i) to determine which indices could detect differences in maize plants treated with different N fertilizer rates, and ii) to evaluate its ability to identify N-responsive from non-responsive sites.
Resumo:
El principal objetivo de la tesis es estudiar el acoplamiento entre los subsistemas de control de actitud y de control térmico de un pequeño satélite, con el fin de buscar la solución a los problemas relacionados con la determinación de los parámetros de diseño. Se considera la evolución de la actitud y de las temperaturas del satélite bajo la influencia de dos estrategias de orientación diferentes: 1) estabilización magnética pasiva de la orientación (PMAS, passive magnetic attitude stabilization), y 2) control de actitud magnético activo (AMAC, active magnetic attitude control). En primer lugar se presenta el modelo matemático del problema, que incluye la dinámica rotacional y el modelo térmico. En el problema térmico se considera un satélite cúbico modelizado por medio de siete nodos (seis externos y uno interno) aplicando la ecuación del balance térmico. Una vez establecido el modelo matemático del problema, se estudia la evolución que corresponde a las dos estrategias mencionadas. La estrategia PMAS se ha seleccionado por su simplicidad, fiabilidad, bajo coste, ahorrando consumo de potencia, masa coste y complejidad, comparado con otras estrategias. Se ha considerado otra estrategia de control que consigue que el satélite gire a una velocidad requerida alrededor de un eje deseado de giro, pudiendo controlar su dirección en un sistema inercial de referencia, ya que frecuentemente el subsistema térmico establece requisitos de giro alrededor de un eje del satélite orientado en una dirección perpendicular a la radiación solar incidente. En relación con el problema térmico, para estudiar la influencia de la velocidad de giro en la evolución de las temperaturas en diversos puntos del satélite, se ha empleado un modelo térmico linealizado, obtenido a partir de la formulación no lineal aplicando un método de perturbaciones. El resultado del estudio muestra que el tiempo de estabilización de la temperatura y la influencia de las cargas periódicas externas disminuye cuando aumenta la velocidad de giro. Los cambios de temperatura se reducen hasta ser muy pequeños para velocidades de rotación altas. En relación con la estrategia PMAC se ha observado que a pesar de su uso extendido entre los micro y nano satélites todavía presenta problemas que resolver. Estos problemas están relacionados con el dimensionamiento de los parámetros del sistema y la predicción del funcionamiento en órbita. Los problemas aparecen debido a la dificultad en la determinación de las características magnéticas de los cuerpos ferromagnéticos (varillas de histéresis) que se utilizan como amortiguadores de oscilaciones en los satélites. Para estudiar este problema se presenta un modelo analítico que permite estimar la eficiencia del amortiguamiento, y que se ha aplicado al estudio del comportamiento en vuelo de varios satélites, y que se ha empleado para comparar los resultados del modelo con los obtenidos en vuelo, observándose que el modelo permite explicar satisfactoriamente el comportamiento registrado. ABSTRACT The main objective of this thesis is to study the coupling between the attitude control and thermal control subsystems of a small satellite, and address the solution to some existing issues concerning the determination of their parameters. Through the thesis the attitude and temperature evolution of the satellite is studied under the influence of two independent attitude stabilization and control strategies: (1) passive magnetic attitude stabilization (PMAS), and (2) active magnetic attitude control (AMAC). In this regard the mathematical model of the problem is explained and presented. The mathematical model includes both the rotational dynamics and the thermal model. The thermal model is derived for a cubic satellite by solving the heat balance equation for 6 external and 1 internal nodes. Once established the mathematical model of the problem, the above mentioned attitude strategies were applied to the system and the temperature evolution of the 7 nodes of the satellite was studied. The PMAS technique has been selected to be studied due to its prevalent use, simplicity, reliability, and cost, as this strategy significantly saves the overall power, weight, cost, and reduces the complexity of the system compared to other attitude control strategies. In addition to that, another control law that provides the satellite with a desired spin rate along a desired axis of the satellite, whose direction can be controlled with respect to the inertial reference frame is considered, as the thermal subsystem of a satellite usually demands a spin requirement around an axis of the satellite which is positioned perpendicular to the direction of the coming solar radiation. Concerning the thermal problem, to study the influence of spin rate on temperature evolution of the satellite a linear approach of the thermal model is used, which is based on perturbation theory applied to the nonlinear differential equations of the thermal model of a spacecraft moving in a closed orbit. The results of this study showed that the temperature stabilization time and the periodic influence of the external thermal loads decreases by increasing the spin rate. However, the changes become insignificant for higher values of spin rate. Concerning the PMAS strategy, it was observed that in spite of its extended application to micro and nano satellites, still there are some issues to be solved regarding this strategy. These issues are related to the sizing of its system parameters and predicting the in-orbit performance. The problems were found to be rooted in the difficulties that exist in determining the magnetic characteristics of the ferromagnetic bodies (hysteresis rods) that are applied as damping devices on-board satellites. To address these issues an analytic model for estimating their damping efficiency is proposed and applied to several existing satellites in order to compare the results with their respective in-flight data. This model can explain the behavior showed by these satellites.
Resumo:
El objetivo principal de esta tesis ha sido el diseño y la optimización de receptores implementados con fibra óptica, para ser usados en redes ópticas de alta velocidad que empleen formatos de modulación de fase. En los últimos años, los formatos de modulación de fase (Phase Shift keying, PSK) han captado gran atención debido a la mejora de sus prestaciones respecto a los formatos de modulación convencionales. Principalmente, presentan una mejora de la eficiencia espectral y una mayor tolerancia a la degradación de la señal causada por la dispersión cromática, la dispersión por modo de polarización y los efectos no-lineales en la fibra óptica. En este trabajo, se analizan en detalle los formatos PSK, incluyendo sus variantes de modulación de fase diferencial (Differential Phase Shift Keying, DPSK), en cuadratura (Differential Quadrature Phase Shift Keying, DQPSK) y multiplexación en polarización (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), con la finalidad de diseñar y optimizar los receptores que permita su demodulación. Para ello, se han analizado y desarrollado nuevas estructuras que ofrecen una mejora en las prestaciones del receptor y una reducción de coste comparadas con las actualmente disponibles. Para la demodulación de señales DPSK, en esta tesis, se proponen dos nuevos receptores basados en un interferómetro en línea Mach-Zehnder (MZI) implementado con tecnología todo-fibra. El principio de funcionamiento de los MZI todo-fibra propuestos se asienta en la interferencia modal que se produce en una fibra multimodo (MMF) cuando se situada entre dos monomodo (SMF). Este tipo de configuración (monomodo-multimodo-monomodo, SMS) presenta un buen ratio de extinción interferente si la potencia acoplada en la fibra multimodo se reparte, principal y equitativamente, entre dos modos dominantes. Con este objetivo, se han estudiado y demostrado tanto teórica como experimentalmente dos nuevas estructuras SMS que mejoran el ratio de extinción. Una de las propuestas se basa en emplear una fibra multimodo de índice gradual cuyo perfil del índice de refracción presenta un hundimiento en su zona central. La otra consiste en una estructura SMS con las fibras desalineadas y donde la fibra multimodo es una fibra de índice gradual convencional. Para las dos estructuras, mediante el análisis teórico desarrollado, se ha demostrado que el 80 – 90% de la potencia de entrada se acopla a los dos modos dominantes de la fibra multimodo y se consigue una diferencia inferior al 10% entre ellos. También se ha demostrado experimentalmente que se puede obtener un ratio de extinción de al menos 12 dB. Con el objeto de demostrar la capacidad de estas estructuras para ser empleadas como demoduladores de señales DPSK, se han realizado numerosas simulaciones de un sistema de transmisión óptico completo y se ha analizado la calidad del receptor bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo o la tolerancia a las dispersiones cromática y por modo de polarización. En todos los casos se ha concluido que los receptores propuestos presentan rendimientos comparables a los obtenidos con receptores convencionales. En esta tesis, también se presenta un diseño alternativo para la implementación de un receptor DQPSK, basado en el uso de una fibra mantenedora de la polarización (PMF). A través del análisi teórico y del desarrollo de simulaciones numéricas, se ha demostrado que el receptor DQPSK propuesto presenta prestaciones similares a los convencionales. Para complementar el trabajo realizado sobre el receptor DQPSK basado en PMF, se ha extendido el estudio de su principio de demodulación con el objeto de demodular señales PM-DQPSK, obteniendo como resultado la propuesta de una nueva estructura de demodulación. El receptor PM-DQPSK propuesto se basa en la estructura conjunta de una única línea de retardo junto con un rotador de polarización. Se ha analizado la calidad de los receptores DQPSK y PM-DQPSK bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo, la tolerancia a las dispersiones cromática y por modo de polarización o su comportamiento bajo condiciones no-ideales. En comparación con los receptores convencionales, nuestra propuesta exhibe prestaciones similares y además permite un diseño más simple que redunda en un coste potencialmente menor. En las redes de comunicaciones ópticas actuales se utiliza la tecnología de multimplexación en longitud de onda (WDM) que obliga al uso de filtros ópticos con bandas de paso lo más estrechas posibles y a emplear una serie de dispositivos que incorporan filtros en su arquitectura, tales como los multiplexores, demultiplexores, ROADMs, conmutadores y OXCs. Todos estos dispositivos conectados entre sí son equivalentes a una cadena de filtros cuyo ancho de banda se va haciendo cada vez más estrecho, llegando a distorsionar la forma de onda de las señales. Por esto, además de analizar el impacto del filtrado óptico en las señales de 40 Gbps DQPSK y 100 Gbps PM-DQPSK, este trabajo de tesis se completa estudiando qué tipo de filtro óptico minimiza las degradaciones causadas en la señal y analizando el número máximo de filtros concatenados que permiten mantener la calidad requerida al sistema. Se han estudiado y simulado cuatro tipos de filtros ópticos;Butterworth, Bessel, FBG y F-P. ABSTRACT The objective of this thesis is the design and optimization of optical fiber-based phase shift keying (PSK) demodulators for high-bit-rate optical networks. PSK modulation formats have attracted significant attention in recent years, because of the better performance with respect to conventional modulation formats. Principally, PSK signals can improve spectrum efficiency and tolerate more signal degradation caused by chromatic dispersion, polarization mode dispersion and nonlinearities in the fiber. In this work, many PSK formats were analyzed in detail, including the variants of differential phase modulation (Differential Phase Shift Keying, DPSK), in quadrature (Differential Quadrature Phase Shift Keying, DQPSK) and polarization multiplexing (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), in order to design and optimize receivers enabling demodulations. Therefore, novel structures, which offer good receiver performances and a reduction in cost compared to the current structures, have been analyzed and developed. Two novel receivers based on an all-fiber in-line Mach-Zehnder interferometer (MZI) were proposed for DPSK signal demodulation in this thesis. The operating principle of the all-fiber MZI is based on the modal interference that occurs in a multimode fiber (MMF) when it is located between two single-mode fibers (SMFs). This type of configuration (Single-mode-multimode-single-mode, SMS) can provide a good extinction ratio if the incoming power from the SMF could be coupled equally into two dominant modes excited in the MMF. In order to improve the interference extinction ratio, two novel SMS structures have been studied and demonstrated, theoretically and experimentally. One of the two proposed MZIs is based on a graded-index multimode fiber (MMF) with a central dip in the index profile, located between two single-mode fibers (SMFs). The other one is based on a conventional graded-index MMF mismatch spliced between two SMFs. Theoretical analysis has shown that, in these two schemes, 80 – 90% of the incoming power can be coupled into the two dominant modes exited in the MMF, and the power difference between them is only ~10%. Experimental results show that interference extinction ratio of 12 dB could be obtained. In order to demonstrate the capacity of these two structures for use as DPSK signal demodulators, numerical simulations in a completed optical transmission system have been carried out, and the receiver quality has been analyzed under different perspectives, such as sensitivity, tolerance to severe optical filtering or tolerance to chromatic and polarization mode dispersion. In all cases, from the simulation results we can conclude that the two proposed receivers can provide performances comparable to conventional ones. In this thesis, an alternative design for the implementation of a DQPSK receiver, which is based on a polarization maintaining fiber (PMF), was also presented. To complement the work made for the PMF-based DQPSK receiver, the study of the demodulation principle has been extended to demodulate PM-DQPSK signals, resulting in the proposal of a novel demodulation structure. The proposed PM-DQPSK receiver is based on only one delay line and a polarization rotator. The quality of the proposed DQPSK and PM-DQPSK receivers under different perspectives, such as sensitivity, tolerance to severe optical filtering, tolerance to chromatic dispersion and polarization mode dispersion, or behavior under non-ideal conditions. Compared with the conventional receivers, our proposals exhibit similar performances but allow a simpler design which can potentially reduce the cost. The wavelength division multiplexing (WDM) technology used in current optical communications networks requires the use of optical filters with a passband as narrow as possible, and the use of a series of devices that incorporate filters in their architecture, such as multiplexers, demultiplexers, switches, reconfigurable add-drop multiplexers (ROADMs) and optical cross-connects (OXCs). All these devices connected together are equivalent to a chain of filters whose bandwidth becomes increasingly narrow, resulting in distortion to the waveform of the signals. Therefore, in addition to analyzing the impact of optical filtering on signal of 40 Gbps DQPSK and 100 Gbps PM-DQPSK, we study which kind of optical filter minimizes the signal degradation and analyze the maximum number of concatenated filters for maintaining the required quality of the system. Four types of optical filters, including Butterworth, Bessel, FBG and FP, have studied and simulated.
Resumo:
The beam properties of tapered semiconductor optical amplifiers emitting at 1.57 μm are analyzed by means of simulations with a self-consistent steady state electro-optical and thermal simulator. The results indicate that the self-focusing caused by carrier lensing is delayed to higher currents for devices with taper angle slightly higher than the free diffraction angle.
Resumo:
Los Centros de Datos se encuentran actualmente en cualquier sector de la economía mundial. Están compuestos por miles de servidores, dando servicio a los usuarios de forma global, las 24 horas del día y los 365 días del año. Durante los últimos años, las aplicaciones del ámbito de la e-Ciencia, como la e-Salud o las Ciudades Inteligentes han experimentado un desarrollo muy significativo. La necesidad de manejar de forma eficiente las necesidades de cómputo de aplicaciones de nueva generación, junto con la creciente demanda de recursos en aplicaciones tradicionales, han facilitado el rápido crecimiento y la proliferación de los Centros de Datos. El principal inconveniente de este aumento de capacidad ha sido el rápido y dramático incremento del consumo energético de estas infraestructuras. En 2010, la factura eléctrica de los Centros de Datos representaba el 1.3% del consumo eléctrico mundial. Sólo en el año 2012, el consumo de potencia de los Centros de Datos creció un 63%, alcanzando los 38GW. En 2013 se estimó un crecimiento de otro 17%, hasta llegar a los 43GW. Además, los Centros de Datos son responsables de más del 2% del total de emisiones de dióxido de carbono a la atmósfera. Esta tesis doctoral se enfrenta al problema energético proponiendo técnicas proactivas y reactivas conscientes de la temperatura y de la energía, que contribuyen a tener Centros de Datos más eficientes. Este trabajo desarrolla modelos de energía y utiliza el conocimiento sobre la demanda energética de la carga de trabajo a ejecutar y de los recursos de computación y refrigeración del Centro de Datos para optimizar el consumo. Además, los Centros de Datos son considerados como un elemento crucial dentro del marco de la aplicación ejecutada, optimizando no sólo el consumo del Centro de Datos sino el consumo energético global de la aplicación. Los principales componentes del consumo en los Centros de Datos son la potencia de computación utilizada por los equipos de IT, y la refrigeración necesaria para mantener los servidores dentro de un rango de temperatura de trabajo que asegure su correcto funcionamiento. Debido a la relación cúbica entre la velocidad de los ventiladores y el consumo de los mismos, las soluciones basadas en el sobre-aprovisionamiento de aire frío al servidor generalmente tienen como resultado ineficiencias energéticas. Por otro lado, temperaturas más elevadas en el procesador llevan a un consumo de fugas mayor, debido a la relación exponencial del consumo de fugas con la temperatura. Además, las características de la carga de trabajo y las políticas de asignación de recursos tienen un impacto importante en los balances entre corriente de fugas y consumo de refrigeración. La primera gran contribución de este trabajo es el desarrollo de modelos de potencia y temperatura que permiten describes estos balances entre corriente de fugas y refrigeración; así como la propuesta de estrategias para minimizar el consumo del servidor por medio de la asignación conjunta de refrigeración y carga desde una perspectiva multivariable. Cuando escalamos a nivel del Centro de Datos, observamos un comportamiento similar en términos del balance entre corrientes de fugas y refrigeración. Conforme aumenta la temperatura de la sala, mejora la eficiencia de la refrigeración. Sin embargo, este incremente de la temperatura de sala provoca un aumento en la temperatura de la CPU y, por tanto, también del consumo de fugas. Además, la dinámica de la sala tiene un comportamiento muy desigual, no equilibrado, debido a la asignación de carga y a la heterogeneidad en el equipamiento de IT. La segunda contribución de esta tesis es la propuesta de técnicas de asigación conscientes de la temperatura y heterogeneidad que permiten optimizar conjuntamente la asignación de tareas y refrigeración a los servidores. Estas estrategias necesitan estar respaldadas por modelos flexibles, que puedan trabajar en tiempo real, para describir el sistema desde un nivel de abstracción alto. Dentro del ámbito de las aplicaciones de nueva generación, las decisiones tomadas en el nivel de aplicación pueden tener un impacto dramático en el consumo energético de niveles de abstracción menores, como por ejemplo, en el Centro de Datos. Es importante considerar las relaciones entre todos los agentes computacionales implicados en el problema, de forma que puedan cooperar para conseguir el objetivo común de reducir el coste energético global del sistema. La tercera contribución de esta tesis es el desarrollo de optimizaciones energéticas para la aplicación global por medio de la evaluación de los costes de ejecutar parte del procesado necesario en otros niveles de abstracción, que van desde los nodos hasta el Centro de Datos, por medio de técnicas de balanceo de carga. Como resumen, el trabajo presentado en esta tesis lleva a cabo contribuciones en el modelado y optimización consciente del consumo por fugas y la refrigeración de servidores; el modelado de los Centros de Datos y el desarrollo de políticas de asignación conscientes de la heterogeneidad; y desarrolla mecanismos para la optimización energética de aplicaciones de nueva generación desde varios niveles de abstracción. ABSTRACT Data centers are easily found in every sector of the worldwide economy. They consist of tens of thousands of servers, serving millions of users globally and 24-7. In the last years, e-Science applications such e-Health or Smart Cities have experienced a significant development. The need to deal efficiently with the computational needs of next-generation applications together with the increasing demand for higher resources in traditional applications has facilitated the rapid proliferation and growing of data centers. A drawback to this capacity growth has been the rapid increase of the energy consumption of these facilities. In 2010, data center electricity represented 1.3% of all the electricity use in the world. In year 2012 alone, global data center power demand grew 63% to 38GW. A further rise of 17% to 43GW was estimated in 2013. Moreover, data centers are responsible for more than 2% of total carbon dioxide emissions. This PhD Thesis addresses the energy challenge by proposing proactive and reactive thermal and energy-aware optimization techniques that contribute to place data centers on a more scalable curve. This work develops energy models and uses the knowledge about the energy demand of the workload to be executed and the computational and cooling resources available at data center to optimize energy consumption. Moreover, data centers are considered as a crucial element within their application framework, optimizing not only the energy consumption of the facility, but the global energy consumption of the application. The main contributors to the energy consumption in a data center are the computing power drawn by IT equipment and the cooling power needed to keep the servers within a certain temperature range that ensures safe operation. Because of the cubic relation of fan power with fan speed, solutions based on over-provisioning cold air into the server usually lead to inefficiencies. On the other hand, higher chip temperatures lead to higher leakage power because of the exponential dependence of leakage on temperature. Moreover, workload characteristics as well as allocation policies also have an important impact on the leakage-cooling tradeoffs. The first key contribution of this work is the development of power and temperature models that accurately describe the leakage-cooling tradeoffs at the server level, and the proposal of strategies to minimize server energy via joint cooling and workload management from a multivariate perspective. When scaling to the data center level, a similar behavior in terms of leakage-temperature tradeoffs can be observed. As room temperature raises, the efficiency of data room cooling units improves. However, as we increase room temperature, CPU temperature raises and so does leakage power. Moreover, the thermal dynamics of a data room exhibit unbalanced patterns due to both the workload allocation and the heterogeneity of computing equipment. The second main contribution is the proposal of thermal- and heterogeneity-aware workload management techniques that jointly optimize the allocation of computation and cooling to servers. These strategies need to be backed up by flexible room level models, able to work on runtime, that describe the system from a high level perspective. Within the framework of next-generation applications, decisions taken at this scope can have a dramatical impact on the energy consumption of lower abstraction levels, i.e. the data center facility. It is important to consider the relationships between all the computational agents involved in the problem, so that they can cooperate to achieve the common goal of reducing energy in the overall system. The third main contribution is the energy optimization of the overall application by evaluating the energy costs of performing part of the processing in any of the different abstraction layers, from the node to the data center, via workload management and off-loading techniques. In summary, the work presented in this PhD Thesis, makes contributions on leakage and cooling aware server modeling and optimization, data center thermal modeling and heterogeneityaware data center resource allocation, and develops mechanisms for the energy optimization for next-generation applications from a multi-layer perspective.
Resumo:
SUNRISE is a balloon-borne solar telescope flown with a long-duration balloon by NASA's Columbia Scientific Balloon Facility team from Esrange (Swedish Space Corporation), on 8 June 2009. SUNRISE has been a challenging mission from the thermal point of view because of its size and power dissipation. Thus, a dedicated thermal analysis has been carried out to find a solution that allows all the devices to be kept within their appropriate temperature ranges, without exceeding the allowable temperature gradients, critical for optical devices. In this article, the thermal design of SUNRISE is described. A geometrical mathematical model and a thermal mathematical model of the whole system have been set up for the different load cases in order to obtain the temperature distribution and gradients in the system. Some trade-offs have been necessary to fulfil all the thermal requirements. The thermal hardware used to achieve it is described. Finally, the temperatures obtained with the models have been compared with flight data.
Resumo:
SUNRISE is a balloon-borne solar telescope flown with a long-duration balloon by NASA's Columbia Scientific Balloon Facility team from Esrange (Swedish Space Corporation), on 8 June 2009. SUNRISE has been a challenging mission from the thermal point of view because of its size and power dissipation. Thus, a dedicated thermal analysis has been carried out to find a solution that allows all the devices to be kept within their appropriate temperature ranges, without exceeding the allowable temperature gradients, critical for optical devices. In this article, the thermal design of SUNRISE is described. A geometrical mathematical model and a thermal mathematical model of the whole system have been set up for the different load cases in order to obtain the temperature distribution and gradients in the system. Some trade-offs have been necessary to fulfil all the thermal requirements. The thermal hardware used to achieve it is described. Finally, the temperatures obtained with the models have been compared with flight data.
Resumo:
El sector energético, en España en particular, y de forma similar en los principales países de Europa, cuenta con una significativa sobrecapacidad de generación, debido al rápido y significativo crecimiento de las energías renovables en los últimos diez años y la reducción de la demanda energética, como consecuencia de la crisis económica. Esta situación ha hecho que las centrales térmicas de generación de electricidad, y en concreto los ciclos combinados de gas, operen con un factor de utilización extremadamente bajo, del orden del 10%. Además de la reducción de ingresos, esto supone para las plantas trabajar continuamente fuera del punto de diseño, provocando una significativa pérdida de rendimiento y mayores costes de explotación. En este escenario, cualquier contribución que ayude a mejorar la eficiencia y la condición de los equipos, es positivamente considerada. La gestión de activos está ganando relevancia como un proceso multidisciplinar e integrado, tal y como refleja la reciente publicación de las normas ISO 55000:2014. Como proceso global e integrado, la gestión de activos requiere el manejo de diversos procesos y grandes volúmenes de información, incluso en tiempo real. Para ello es necesario utilizar tecnologías de la información y aplicaciones de software. Esta tesis desarrolla un concepto integrado de gestión de activos (Integrated Plant Management – IPM) aplicado a centrales de ciclo combinado y una metodología para estimar el beneficio aportado por el mismo. Debido a las incertidumbres asociadas a la estimación del beneficio, se ha optado por un análisis probabilístico coste-beneficio. Así mismo, el análisis cuantitativo se ha completado con una validación cualitativa del beneficio aportado por las tecnologías incorporadas al concepto de gestión integrada de activos, mediante una entrevista realizada a expertos del sector de generación de energía. Los resultados del análisis coste-beneficio son positivos, incluso en el desfavorable escenario con un factor de utilización de sólo el 10% y muy prometedores para factores de utilización por encima del 30%. ABSTRACT The energy sector particularly in Spain, and in a similar way in Europe, has a significant overcapacity due to the big growth of the renewable energies in the last ten years, and it is seriously affected by the demand decrease due to the economic crisis. That situation has forced the thermal plants and in particular, the combined cycles to operate with extremely low annual average capacity factors, very close to 10%. Apart from the incomes reduction, working in out-of-design conditions, means getting a worse performance and higher costs than expected. In this scenario, anything that can be done to improve the efficiency and the equipment condition is positively received. Asset Management, as a multidisciplinary and integrated process, is gaining prominence, reflected in the recent publication of the ISO 55000 series in 2014. Dealing Asset Management as a global, integrated process needs to manage several processes and significant volumes of information, also in real time, that requires information technologies and software applications to support it. This thesis proposes an integrated asset management concept (Integrated Plant Management-IPM) applied to combined cycle power plants and develops a methodology to assess the benefit that it can provide. Due to the difficulties in getting deterministic benefit estimation, a statistical approach has been adopted for the cot-benefit analysis. As well, the quantitative analysis has been completed with a qualitative validation of the technologies included in the IPM and their contribution to key power plant challenges by power generation sector experts. The cost- benefit analysis provides positive results even in the negative scenario of annual average capacity factor close to 10% and is promising for capacity factors over 30%.