50 resultados para Fiber reinforced polymers (FRP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thermal and mechanical behaviour of isotactic polypropylene (iPP) nanocomposites reinforced with different loadings of inorganic fullerene-like tungsten disulfide (IF-WS2) nanoparticles was investigated. The IF-WS2 noticeably enhanced the polymer stiffness and strength, ascribed to their uniform dispersion, the formation of a large nanoparticle?matrix interface combined with a nucleating effect on iPP crystallization. Their reinforcement effect was more pronounced at high temperatures. However, a drop in ductility and toughness was found at higher IF-WS2 concentrations. The tensile behaviour of the nanocomposites was extremely sensitive to the strain rate and temperature, and their yield strength was properly described by the Eyring s equation. The activation energy increased while the activation volume decreased with increasing nanoparticle loading, indicating a reduction in polymer chain motion. The nanoparticles improved the thermomechanical properties of iPP: raised the glass transition and heat deflection temperatures while decreased the coefficient of thermal expansion. The nanocomposites also displayed superior flame retardancy with longer ignition time and reduced peak heat release rate. Further, a gradual rise in thermal conductivity was found with increasing IF-WS2 loading both in the glassy and rubbery states. The results presented herein highlight the benefits and high potential of using IF-nanoparticles for enhancing the thermomechanical properties of thermoplastic polymers compared to other nanoscale fillers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El uso de refuerzos NSM‐FRP en estructuras de hormigón armado se ha incrementado considerablemente en los últimos años como método de refuerzo estructural. Los ensayos de arrancamiento en viga de los refuerzos NSM‐FRP permiten el estudio del comportamiento de la unión pegada. El principal objetivo del presente trabajo aborda la simulación numérica de este tipo de ensayos, con el propósito de caracterizar correctamente la adherencia entre las barras de NSM‐FRP y el hormigón. En una fase inicial se simuló un modelo bidimensional para conseguir evaluar y verificar el comportamiento de los elementos cohesivos y ver su comportamiento primero ante diferentes modelos de material y segundo ante un modo mixto de fallo, debido a la aplicación simultanea de carga axial y carga cortante. En una segunda fase se creó un modelo tridimensional para estudiar el arrancamiento de una barra de material compuesto insertada en hormigón, creando un modelo de material de hormigón y viendo el comportamiento cualitativo del sistema ante variaciones en los parámetros de los diferentes materiales. En la tercera fase, la más importante del presente trabajo, se abordó la simulación numérica del ensayo de arrancamiento en viga. Se simularon todos los componentes del ensayo y se evaluaron diferentes alternativas para representar la interfase NSM‐FRP ‐ hormigón, usando elementos cohesivos y diferentes distribuciones de los mismos en la interfase. Para conseguir representar lo más fielmente posible las condiciones del ensayo, se diseñó también un controlador PID que permite realizar las simulaciones numéricas mediante un control en desplazamientos, lo cual permite capturar más correctamente el comportamiento de reblandecimiento de la unión pegada. El controlador PID aplica técnicas de ingeniería de control para conseguir calcular a priori la amplitud necesaria del desplazamiento impuesto que provoque una evolución establecida en una variable interna del sistema. La variable usada para correlacionar los ensayos es la diferencia en desplazamientos entre dos puntos y se escoge una evolución lineal de la misma, pero en la tesis también se exponen los resultados de escoger otras posibles variables internas con diferentes evoluciones. Se compararon las simulaciones numéricas con resultados de mediciones experimentales previamente publicadas. Los resultados carga‐deslizamiento obtenidos encajan bien con los datos experimentales. El modelo propuesto es también capaz de predecir el modo de fallo en la interfase NSM‐FRP ‐ hormigón. Finalmente, también se han llevado a cabo estudios paramétricos, para evaluar la influencia de cada parámetro en los resultados. También se realizó un estudio cualitativo de cómo se comporta la unión pegada en cada momento de la simulación, mediante el uso macros y gráficas tridimensionales, para conseguir una mejor visualización y facilitar el análisis de los resultados. ABSTRACT The use of near‐surface mounted FRP reinforcement in reinforced concrete structures has seen a considerable increase in recent years as a strengthening method. Beam pull‐out tests for near‐surface reinforcement allow obtaining the local bond‐slip behavior of a bonded joint. The main objective of the current work deals with the three‐dimensional modeling of this kind of test with the purpose of characterizing suitably the mechanics of bond between FRP rods and concrete. In an initial stage, a two bidimensional in order to evaluate and to verify the behavior of the cohesive elements. Its behavior was evaluated first testing different material models and second testing the behavior when mixed mode failure appears, due to simultaneous axial and shear load. In a second stage a tridimensional model was created in order to study the pull‐out of an inserted beam of composite material in concrete. A concrete material model was created and the influence of each material parameter was studied qualitatively. The third part, the most relevant of the present work, the numerical simulation of the Beam Pull‐Out test was faced. All the parts of the Beam Pull‐Out test were included inthe simulation and different alternatives to represent the FRP bar – concrete interface have been evaluated, using cohesive elements and different distributions of them. In order to reproduce the test conditions more reliably, a PID controller has also been designed to conduct suitably the numerical tests in order to properly capture the softening branch of the load‐slip behaviour. The PID controller applies control techniques to calculate a priori the necessary amplitude of the load in order to achieve a given evolution through the simulation of an internal variable previously chosen. The variable used in order to correlate the simulation with the test results is the difference in displacements between two points and a linear evolution was chosen, but in the thesis the results of choosing other possible internal variables with different evolutions are also shown. The numerical FE simulations were compared with experimental measurements previously published. Load‐slip predictions compare well with the corresponding experimental data. The proposed model is also able to predict the failure mode at the FRP‐concrete interface. Some parametric studies have also been carried out, in order to evaluate the influence of each material parameter in the results. A qualitative study of the behaviour of the joint was also performed, using the results of the numeric simulations and through the use of macros and 3D graphs, the tensional state of each point of the joint can be visualized in each moment of the simulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En el presente trabajo se lleva a cabo un estudio basado en datos obtenidos experimentalmente mediante el ensayo a flexión de vigas de madera de pino silvestre reforzadas con materiales compuestos. Las fibras que componen los tejidos utilizados para la ejecución de los refuerzos son de basalto y de carbono. En el caso de los compuestos de fibra de basalto se aplican en distintos gramajes, y los de carbono en tejido unidireccional y bidireccional. El material compuesto se realizó in situ, simultáneamente a la ejecución del refuerzo. Se aplicaron en una y en dos capas, según el caso, y la forma de colocación fue en ?U?, adhiriéndose al canto inferior y a las caras laterales de la viga mediante resina o mortero epoxi. Se analiza el comportamiento de las vigas según las variables de refuerzo aplicadas y se comparan con los resultados de vigas ensayadas sin reforzar. Con este trabajo queda demostrado el buen funcionamiento del FRP de fibra de basalto aplicado en el refuerzo de vigas de madera y de los tejidos de carbono bidireccionales con respecto a los unidireccionales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A significant amount of research has been conducted on FRP-confined circular columns, but much less is known about rectangular/square columns in which the effectiveness of confinement is much reduced. This paper presents the results of experimental investigations on low strength square concrete columns confined with FRP. Axial compression tests were performed on ten intermediate size columns. The tests results indicate that FRP composites can significantly improve the bearing capacity and ductility of square section reinforced concrete columns with rounded corners. The strength enhancement ratio is greater the lower the concrete strength and also increases with the stiffness of the jacket. The confined concrete behaviour was predicted according to the more accepted theoretical models and compared with experimental results. There are two key parameters which critically influence the fitting of the models: the strain efficiency factor and the effect of confinement in non-circular sections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of the carbon nanotubes (CNTs) content on the fiber/matrix interfacial shear strength (IFSS) in glass/fiber epoxy composites was measured by means of push-in and push-out tests. Both experimental methodologies provided equivalent values of the IFSS for each material. It was found that the dispersion of CNTs increased in IFSS by 19% in average with respect to the composite without CNTs. This improvement was reached with 0.3 wt.% of CNTs and increasing the CNT content up to 0.8 wt.% did not improve the interface strength.