57 resultados para Energy flow levels


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of fiber inclusion, feed form, and energy concentration of the diet on the growth performance of pullets from hatching to 5 wk age were studied in 2 experiments. In Experiment 1, there was a control diet based on cereals and soybean meal, and 6 extra diets that included 2 or 4% of cereal straw, sugar beet pulp (SBP), or sunflower hulls (SFHs) at the expense (wt/wt) of the whole control diet. From hatching to 5 wk age fiber inclusion increased (P < 0.05) ADG and ADFI, and improved (P < 0.05) energy efficiency (EnE; kcal AMEn/g ADG), but body weight (BW) uniformity was not affected. Pullets fed SFH tended to have higher ADG than pullets fed SBP (P = 0.072) with pullets fed straw being intermediate. The feed conversion ratio (FCR) was better (P < 0.05) with 2% than with 4% fiber inclusion. In Experiment 2, 10 diets were arranged as a 2×5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of AMEn (2,850, 2,900, 2,950, 3,000, and 3,050 kcal/kg). Pullets fed crumbles were heavier and had better FCR than pullets fed mash (P < 0.001). An increase in the energy content of the crumble diets reduced ADFI and improved FCR linearly, but no effects were detected with the mash diets (P < 0.01 and P < 0.05 for the interactions). Feeding crumbles tended to improve BW uniformity at 5 wk age (P = 0.077) but no effects were detected with increases in energy concentration of the diet. In summary, the inclusion of moderate amounts of fiber in the diet improves pullet performance from hatching to 5 wk age. The response of pullets to increases in energy content of the diet depends on feed form with a decrease in feed intake when fed crumbles but no changes when fed mash. Feeding crumbles might be preferred to feeding mash in pullets from hatching to 5 wk age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of feed form and energy concentration of the diet on growth performance and the development of the gastrointestinal tract (GIT) was studied in brown-egg laying pullets. Diets formed a 2 x 5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of energy differing in 50 kcal AMEn/kg. For the entire study (0 to 17 wk of age) feeding crumbles increased ADFI (52.9 vs. 49.7 g; P < 0.001) and ADG (12.7 vs. 11.6 g; P < 0.001) and improved feed conversion ratio (FCR; 4.18 vs. 4.27; P < 0.001). An increase in the energy content of the diet decreased ADFI linearly (P < 0.001) and improved FCR quadratically (P < 0.01) but energy intake (kcal AMEn/d) was not affected. BW uniformity was higher (P < 0.05) in pullets fed crumbles than in those fed mash but was not affected (P > 0.05) by energy content of the diet. At 5, 10, and 17 wk of age, the relative weight (RW, % BW) of the GIT and the gizzard, and gizzard digesta content were lower (P < 0.05 to P < 0.001) and gizzard pH was higher (P < 0.05 to P < 0.001) in pullets fed crumbles than in pullets fed mash. Energy concentration of the diet did not affect any of the GIT variables studied. In summary, feeding crumbles improved pullet performance and reduced the RW of the GIT and gizzard, and increased gizzard pH at all ages. An increase in the energy content of the diet improved FCR from 0 to 17 wk of age. The use of crumbles and the increase in the AMEn content of the diet might be used adventageously when the objetive is to increase the BW of the pullets. However, crumbles affected the development and weight of the organs of the GIT, which might have negative effects on feed intake and egg production at the beginning of the egg laying cycle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El consumo energético de las Redes de Sensores Inalámbricas (WSNs por sus siglas en inglés) es un problema histórico que ha sido abordado desde diferentes niveles y visiones, ya que no solo afecta a la propia supervivencia de la red sino que el creciente uso de dispositivos inteligentes y el nuevo paradigma del Internet de las Cosas hace que las WSNs tengan cada vez una mayor influencia en la huella energética. Debido a la tendencia al alza en el uso de estas redes se añade un nuevo problema, la saturación espectral. Las WSNs operan habitualmente en bandas sin licencia como son las bandas Industrial, Científica y Médica (ISM por sus siglas en inglés). Estas bandas se comparten con otro tipo de redes como Wi-Fi o Bluetooth cuyo uso ha crecido exponencialmente en los últimos años. Para abordar este problema aparece el paradigma de la Radio Cognitiva (CR), una tecnología que permite el acceso oportunista al espectro. La introducción de capacidades cognitivas en las WSNs no solo permite optimizar su eficiencia espectral sino que también tiene un impacto positivo en parámetros como la calidad de servicio, la seguridad o el consumo energético. Sin embargo, por otra parte, este nuevo paradigma plantea algunos retos relacionados con el consumo energético. Concretamente, el sensado del espectro, la colaboración entre los nodos (que requiere comunicación adicional) y el cambio en los parámetros de transmisión aumentan el consumo respecto a las WSN clásicas. Teniendo en cuenta que la investigación en el campo del consumo energético ha sido ampliamente abordada puesto que se trata de una de sus principales limitaciones, asumimos que las nuevas estrategias deben surgir de las nuevas capacidades añadidas por las redes cognitivas. Por otro lado, a la hora de diseñar estrategias de optimización para CWSN hay que tener muy presentes las limitaciones de recursos de estas redes en cuanto a memoria, computación y consumo energético de los nodos. En esta tesis doctoral proponemos dos estrategias de reducción de consumo energético en CWSNs basadas en tres pilares fundamentales. El primero son las capacidades cognitivas añadidas a las WSNs que proporcionan la posibilidad de adaptar los parámetros de transmisión en función del espectro disponible. La segunda es la colaboración, como característica intrínseca de las CWSNs. Finalmente, el tercer pilar de este trabajo es teoría de juegos como algoritmo de soporte a la decisión, ampliamente utilizado en WSNs debido a su simplicidad. Como primer aporte de la tesis se presenta un análisis completo de las posibilidades introducidas por la radio cognitiva en materia de reducción de consumo para WSNs. Gracias a las conclusiones extraídas de este análisis, se han planteado las hipótesis de esta tesis relacionadas con la validez de usar capacidades cognitivas como herramienta para la reducción de consumo en CWSNs. Una vez presentada las hipótesis, pasamos a desarrollar las principales contribuciones de la tesis: las dos estrategias diseñadas para reducción de consumo basadas en teoría de juegos y CR. La primera de ellas hace uso de un juego no cooperativo que se juega mediante pares de jugadores. En la segunda estrategia, aunque el juego continúa siendo no cooperativo, se añade el concepto de colaboración. Para cada una de las estrategias se presenta el modelo del juego, el análisis formal de equilibrios y óptimos y la descripción de la estrategia completa donde se incluye la interacción entre nodos. Con el propósito de probar las estrategias mediante simulación e implementación en dispositivos reales hemos desarrollado un marco de pruebas compuesto por un simulador cognitivo y un banco de pruebas formado por nodos cognitivos capaces de comunicarse en tres bandas ISM desarrollados en el B105 Lab. Este marco de pruebas constituye otra de las aportaciones de la tesis que permitirá el avance en la investigación en el área de las CWSNs. Finalmente, se presentan y discuten los resultados derivados de la prueba de las estrategias desarrolladas. La primera estrategia proporciona ahorros de energía mayores al 65% comparados con una WSN sin capacidades cognitivas y alrededor del 25% si la comparamos con una estrategia cognitiva basada en el sensado periódico del espectro para el cambio de canal de acuerdo a un nivel de ruido fijado. Este algoritmo se comporta de forma similar independientemente del nivel de ruido siempre que éste sea espacialmente uniformemente. Esta estrategia, a pesar de su sencillez, nos asegura el comportamiento óptimo en cuanto a consumo energético debido a la utilización de teoría de juegos en la fase de diseño del comportamiento de los nodos. La estrategia colaborativa presenta mejoras respecto a la anterior en términos de protección frente al ruido en escenarios de ruido más complejos donde aporta una mejora del 50% comparada con la estrategia anterior. ABSTRACT Energy consumption in Wireless Sensor Networks (WSNs) is a known historical problem that has been addressed from different areas and on many levels. But this problem should not only be approached from the point of view of their own efficiency for survival. A major portion of communication traffic has migrated to mobile networks and systems. The increased use of smart devices and the introduction of the Internet of Things (IoT) give WSNs a great influence on the carbon footprint. Thus, optimizing the energy consumption of wireless networks could reduce their environmental impact considerably. In recent years, another problem has been added to the equation: spectrum saturation. Wireless Sensor Networks usually operate in unlicensed spectrum bands such as Industrial, Scientific, and Medical (ISM) bands shared with other networks (mainly Wi-Fi and Bluetooth). To address the efficient spectrum utilization problem, Cognitive Radio (CR) has emerged as the key technology that enables opportunistic access to the spectrum. Therefore, the introduction of cognitive capabilities to WSNs allows optimizing their spectral occupation. Cognitive Wireless Sensor Networks (CWSNs) do not only increase the reliability of communications, but they also have a positive impact on parameters such as the Quality of Service (QoS), network security, or energy consumption. These new opportunities introduced by CWSNs unveil a wide field in the energy consumption research area. However, this also implies some challenges. Specifically, the spectrum sensing stage, collaboration among devices (which requires extra communication), and changes in the transmission parameters increase the total energy consumption of the network. When designing CWSN optimization strategies, the fact that WSN nodes are very limited in terms of memory, computational power, or energy consumption has to be considered. Thus, light strategies that require a low computing capacity must be found. Since the field of energy conservation in WSNs has been widely explored, we assume that new strategies could emerge from the new opportunities presented by cognitive networks. In this PhD Thesis, we present two strategies for energy consumption reduction in CWSNs supported by three main pillars. The first pillar is that cognitive capabilities added to the WSN provide the ability to change the transmission parameters according to the spectrum. The second pillar is that the ability to collaborate is a basic characteristic of CWSNs. Finally, the third pillar for this work is the game theory as a decision-making algorithm, which has been widely used in WSNs due to its lightness and simplicity that make it valid to operate in CWSNs. For the development of these strategies, a complete analysis of the possibilities is first carried out by incorporating the cognitive abilities into the network. Once this analysis has been performed, we expose the hypotheses of this thesis related to the use of cognitive capabilities as a useful tool to reduce energy consumption in CWSNs. Once the analyses are exposed, we present the main contribution of this thesis: the two designed strategies for energy consumption reduction based on game theory and cognitive capabilities. The first one is based on a non-cooperative game played between two players in a simple and selfish way. In the second strategy, the concept of collaboration is introduced. Despite the fact that the game used is also a non-cooperative game, the decisions are taken through collaboration. For each strategy, we present the modeled game, the formal analysis of equilibrium and optimum, and the complete strategy describing the interaction between nodes. In order to test the strategies through simulation and implementation in real devices, we have developed a CWSN framework composed by a CWSN simulator based on Castalia and a testbed based on CWSN nodes able to communicate in three different ISM bands. We present and discuss the results derived by the energy optimization strategies. The first strategy brings energy improvement rates of over 65% compared to WSN without cognitive techniques. It also brings energy improvement rates of over 25% compared with sensing strategies for changing channels based on a decision threshold. We have also seen that the algorithm behaves similarly even with significant variations in the level of noise while working in a uniform noise scenario. The collaborative strategy presents improvements respecting the previous strategy in terms of noise protection when the noise scheme is more complex where this strategy shows improvement rates of over 50%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have analyzed the influence of the actual height of Bolund island above water level on different full-scale statistics of the velocity field over the peninsula. Our analysis is focused on the database of 10-minute statistics provided by Risø-DTU for the Bolund Blind Experiment. We have considered 10-minut.e periods with near-neutral atmospheric conditions, mean wind speed values in the interval [5,20] m/s, and westerly wind directions. As expected, statistics such as speed-up, normalized increase of turbulent kinetic energy and probability of recirculating flow show a large dependence on the emerged height of the island for the locations close to the escarpment. For the published ensemble mean values of speed-up and normalized increase of turbulent kinetic energy in these locations, we propose that some ammount of uncertainty could be explained as a deterministic dependence of the flow field statistics upon the actual height of the Bolund island above the sea level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The three-dimensional wall-bounded open cavity may be considered as a simplified geometry found in industrial applications such as leading gear or slotted flats on the airplane. Understanding the three-dimensional complex flow structure that surrounds this particular geometry is therefore of major industrial interest. At the light of the remarkable former investigations in this kind of flows, enough evidences suggest that the lateral walls have a great influence on the flow features and hence on their instability modes. Nevertheless, even though there is a large body of literature on cavity flows, most of them are based on the assumption that the flow is two-dimensional and spanwise-periodic. The flow over realistic open cavity should be considered. This thesis presents an investigation of three-dimensional wall-bounded open cavity with geometric ratio 6:2:1. To this aim, three-dimensional Direct Numerical Simulation (DNS) and global linear instability have been performed. Linear instability analysis reveals that the onset of the first instability in this open cavity is around Recr 1080. The three-dimensional shear layer mode with a complex structure is shown to be the most unstable mode. I t is noteworthy that the flow pattern of this high-frequency shear layer mode is similar to the observed unstable oscillations in supercritical unstable case. DNS of the cavity flow carried out at different Reynolds number from steady state until a nonlinear saturated state is obtained. The comparison of time histories of kinetic energy presents a clearly dominant energetic mode which shifts between low-frequency and highfrequency oscillation. A complete flow patterns from subcritical cases to supercritical case has been put in evidence. The flow structure at the supercritical case Re=1100 resembles typical wake-shedding instability oscillations with a lateral motion existed in the subcritical cases. Also, This flow pattern is similar to the observations in experiments. In order to validate the linear instability analysis results, the topology of the composite flow fields reconstructed by linear superposition of a three-dimensional base flow and its leading three-dimensional global eigenmodes has been studied. The instantaneous wall streamlines of those composited flows display distinguish influence region of each eigenmode. Attention has been focused on the leading high-frequency shear layer mode; the composite flow fields have been fully recognized with respect to the downstream wave shedding. The three-dimensional shear layer mode is shown to give rise to a typical wake-shedding instability with a lateral motions occurring downstream which is in good agreement with the experiment results. Moreover, the spanwise-periodic, open cavity with the same length to depth ratio has been also studied. The most unstable linear mode is different from the real three-dimensional cavity flow, because of the existence of the side walls. Structure sensitivity of the unstable global mode is analyzed in the flow control context. The adjoint-based sensitivity analysis has been employed to localized the receptivity region, where the flow is more sensible to momentum forcing and mass injection. Because of the non-normality of the linearized Navier-Stokes equations, the direct and adjoint field has a large spatial separation. The strongest sensitivity region is locate in the upstream lip of the three-dimensional cavity. This numerical finding is in agreement with experimental observations. Finally, a prototype of passive flow control strategy is applied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A numerical method to analyse the stability of transverse galloping based on experimental measurements, as an alternative method to polynomial fitting of the transverse force coefficient Cz, is proposed in this paper. The Glauert–Den Hartog criterion is used to determine the region of angles of attack (pitch angles) prone to present galloping. An analytic solution (based on a polynomial curve of Cz) is used to validate the method and to evaluate the discretization errors. Several bodies (of biconvex, D-shape and rhomboidal cross sections) have been tested in a wind tunnel and the stability of the galloping region has been analysed with the new method. An algorithm to determine the pitch angle of the body that allows the maximum value of the kinetic energy of the flow to be extracted is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pesar de los innegables beneficios físicos y psicosociales que la práctica de actividad física tiene para la población en las últimas décadas se observa un importante descenso en el nivel de práctica de actividad física durante la adolescencia. La Educación Física (EF) es una asignatura presente en las primeras etapas educativas de los currículums de todos los países y supone para la población infantil y adolescente, durante el periodo de escolarización obligatoria, un entorno de contacto cotidiano con la actividad física y deportiva lo que explica el creciente interés que existe por investigar en este contexto y extraer conclusiones que puedan ayudar a revertir el proceso de progresivo abandono de la práctica en estas edades. El presente trabajo se centra en un periodo, la adolescencia, especialmente sensible al abandono de la práctica de actividad física. Apoyándonos en tres de los marcos teóricos más importantes de los últimos años - Teoría de Metas de Logro, Teoría de la Autodeterminación y Teoría del Flow - hemos realizado un diseño con tres estudios complementarios que nos permitan avanzar en el conocimiento de las variables que afectan a esta realidad. En el primero de los estudios, en el que participaron 3990 estudiantes de EF de España, Argentina, Colombia y Ecuador con edades comprendidas entre 12 y 18 años, se fijaron como objetivos el establecimiento de perfiles motivacionales en estudiantes de EF considerando las orientaciones motivacionales, la motivación intrínseca y el flow disposicional; la comprobación de la posible estabilidad de los perfiles establecidos en cuatro países diferentes; y el análisis de la relación entre los perfiles motivacionales establecidos con la práctica de actividad física realizada en la actualidad y la intención de ser activo en el futuro. Los resultados revelaron la existencia de tres perfiles motivacionales en los estudiantes: perfil de motivación baja-moderada, perfil de motivación de alta motivación con bajo ego y perfil de alta motivación. Se encontraron similitudes en los perfiles motivacionales obtenidos en los cuatro países analizados, sugiriéndose la posibilidad de que la lengua materna compartida pueda ser una variable de influencia en la existencia de patrones conductuales similares. La orientación al ego resultó ser un elemento diferenciador en la relación de los dos perfiles que mostraron niveles más altos de motivación intrínseca, flow disposicional y orientación a la tarea con las variables de práctica. Mayores niveles de orientación al ego determinaron mayores valores de práctica e intención de práctica. En el segundo estudio, en el que participaron 365 estudiantes de EF de España, Argentina y Colombia con edades comprendidas entre 12 y 16 años, se testó un modelo explicativo de la intención de ser físicamente activo en el futuro en estudiantes de EF poco motivados introduciendo el flow disposicional como variable explicativa junto a las orientaciones motivacionales y la motivación intrínseca. El modelo de ecuaciones estructurales testado muestra que tanto la orientación al ego como la orientación a la tarea y la motivación intrínseca predijeron el flow disposicional. No se encontró un efecto significativo de la orientación a la tarea sobre la motivación intrínseca, ni de esta sobre la intención de práctica de AFD en el futuro. El flow disposicional resultó ser un mediador entre ambas orientaciones motivacionales y dicha intención, adquiriendo un papel relevante en la predicción de la intención de realizar actividad física en el futuro en los sujetos con poca motivación hacia la clase de EF. En el último estudio, con una muestra de 53 estudiantes de EF pertenecientes a dos clases de segundo curso de ESO con edades comprendidas entre 13 y 15 años, se analizó el efecto de una intervención de apoyo a las NPB sobre la satisfacción de las mismas, la motivación intrínseca, la disposición a experimentar flow y la intención de ser físicamente activo en el futuro; estudiándose también el efecto de la misma sobre ciertas variables presentes en el proceso de enseñanza-aprendizaje tales como la diversión, el aprendizaje y el gusto hacia el contenido y la metodología empleada. La intervención resultó efectiva en la mejora de todas las variables motivacionales analizadas a excepción de la satisfacción de la necesidad de relaciones sociales, variable que podría ser más difícilmente modificable en tanto que los grupos de clase suelen permanecer estables a lo largo de esta etapa educativa. Los alumnos de la condición experimental presentaron niveles más elevados de diversión, aprendizaje y gusto hacia el contenido y la metodología empleada. ABSTRACT Despite the undeniable physical and psychological benefits that physical activity has on health, a significant drop in the level of physical activity during adolescence has been observed over the last few decades. Physical education (PE) is present in the early stages of educational curricula of all countries, creating an environment in which children and adolescents can maintain daily contact with sport and physical activity during the period of compulsory education. There is thus a growing interest in research within this context, helping to draw conclusions aimed at reversing the progressive decline of physical activity in this age bracket. The work presented here focuses on adolescence – a period particularly sensitive when faced with declining rates of physical activity. Relying on three of the most important recent theoretical frameworks – Achievement Goal Theory, Self-Determination Theory and Flow Theory – we have carried out a design using three complementary studies that allow us to advance the understanding of variables affecting this reality. The first two studies employ a correlational methodology while the third follows a quasi-experimental design. The objectives of the first study, with the participation of 3990 PE students aged 12 to 18 from Spain, Argentina, Colombia and Ecuador, were: a) to establish motivational profiles in physical education students taking into consideration motivational orientations, intrinsic motivation and dispositional flow; b) to check the possible stability of the established profiles in the four countries; and c) to analyze the relationship between motivational profiles and both current levels of physical activity and intention to be physically active in the future. Results revealed the existence of three motivational profiles: low-moderate motivation profile, high motivation and low ego profile and high motivation profile. Similarities were found across the four countries, which presents the possibility that sharing the same mother tongue might influence the existence of similar behavioral patterns. Amongst the profiles that showed the highest levels of intrinsic motivation, dispositional flow and task orientation with practice variables, ego orientation became apparent as a differentiating element. Higher levels of ego orientation correlated with higher levels both in current level of physical activity and intention to be physically active in the future. In the second study, with the participation of 365 PE students aged 12 to 16 from Spain, Argentina and Colombia, an explanatory model of the intention to be physically active within the low-moderate motivation profile was tested, including dispositional flow as an influence variable together with motivational orientations and intrinsic motivation. The structural model equation in the low-moderate motivation profile shows some differences with respect to findings of similar studies using heterogeneous samples in motivational profiles. It was found that ego orientation, task orientation and intrinsic motivation predicted dispositional flow. No significant effects of task orientation on intrinsic motivation, or of intrinsic motivation on intention to be physically active in the future were found. Dispositional flow emerged as a mediator between both motivational orientations and intention, acquiring an important role in the prediction of future intentions to be physically active in adolescents who show low levels of motivation towards physical education. In the last of the three studies, with the participation of 53 PE students drawn from two classes in the second year of secondary education aged 13 to 15, the effect of an intervention to support basic psychological needs was tested against the satisfaction of these needs, intrinsic motivation, disposition to experience flow and intention to be physically active in the future. Alongside this, the aforementioned intervention was tested on certain variables present in the teaching-learning process such as fun, learning and taste for the activity and methodology. Supportive intervention was effective in improving all the motivational variables, except for the satisfaction of the relatedness variable, which may be more difficult to modify as class groups tend to remain stable throughout this educational state. Students in the experimental condition showed higher levels of fun, learning and taste for the content and methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of fiber inclusion, feed form, and energy concentration of the diet on the growth performance of pullets from hatching to 5 wk age were studied in 2 experiments. In Experiment 1, there was a control diet based on cereals and soybean meal, and 6 extra diets that included 2 or 4% of cereal straw, sugar beet pulp (SBP), or sunflower hulls (SFHs) at the expense (wt/wt) of the whole control diet. From hatching to 5 wk age fiber inclusion increased (P < 0.05) ADG and ADFI, and improved (P < 0.05) energy efficiency (EnE; kcal AMEn/g ADG), but body weight (BW) uniformity was not affected. Pullets fed SFH tended to have higher ADG than pullets fed SBP (P = 0.072) with pullets fed straw being intermediate. The feed conversion ratio (FCR) was better (P < 0.05) with 2% than with 4% fiber inclusion. In Experiment 2, 10 diets were arranged as a 2×5 factorial with 2 feed forms (mash vs. crumbles) and 5 levels of AMEn (2,850, 2,900, 2,950, 3,000, and 3,050 kcal/kg). Pullets fed crumbles were heavier and had better FCR than pullets fed mash (P < 0.001). An increase in the energy content of the crumble diets reduced ADFI and improved FCR linearly, but no effects were detected with the mash diets (P < 0.01 and P < 0.05 for the interactions). Feeding crumbles tended to improve BW uniformity at 5 wk age (P = 0.077) but no effects were detected with increases in energy concentration of the diet. In summary, the inclusion of moderate amounts of fiber in the diet improves pullet performance from hatching to 5 wk age. The response of pullets to increases in energy content of the diet depends on feed form with a decrease in feed intake when fed crumbles but no changes when fed mash. Feeding crumbles might be preferred to feeding mash in pullets from hatching to 5 wk age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Existe en el panorama edificado un patrimonio construido que se reconoce como Centro Comercial. Un conjunto entendido, en sentido genérico, como familia arquitectónica que tiene características propias y específicas que la identifican. El objeto de la presente tesis doctoral consiste en argumentar que este conjunto constituye un nuevo tipo en el panorama de las tipologías arquitectónicas. Un tipo con entidad propia, que se conecta a una forma diferente de entender la idea de modelo. Un concepto que va más allá de la consideración tradicional del término. Modelo virtual. Este tipo, que surge de una estructura teórica que hemos denominado teoría tipológica, se constituye en una herramienta más para el estudio y el desarrollo proyectual de los espacios arquitectónicos, tanto del propio Centro Comercial como del conjunto de la disciplina arquitectónica, como referencia legítima. El presente trabajo de tesis se inicia con un bloque introductorio denominado Método. Definimos en él una metodología que hemos llamado emocional. Trata de la oportunidad de la tesis. Del porqué de un título que recoge la palabra ignorada. Del interés que suscita el asunto en el contexto del momento presente. Oportunidad e interés en base a una vida profesional dedicada al mundo del Centro Comercial y a la importancia del patrimonio elegido como objeto de estudio. También ha sido un aliciente detectar como las planificaciones del territorio y de los ámbitos de las relaciones colectivas no han sido capaces de integrar un resultado satisfactorio. Quizás por no considerar la complejidad de sus muchas facetas. En consecuencia, el texto busca la esencia del Centro Comercial como soporte para la crítica de su impacto en los nuevos escenarios de relación que la sociedad y el entorno físico imponen. Ámbitos donde los mecanismos históricos del asociacionismo tradicional han dado paso a otros, como el Centro Comercial, de exaltación del individualismo, pero demandados por una sociedad que se identifica con ellos. Espacios que, con Galbraith, existen por de la perversidad intrínseca del binomio consumo-producción que inducen la perplejidad. Ésta pasa a formar parte de la esencia del nuevo espacio comercial, como quedó de manifiesto en el Congreso de Minnesota de 1997, sobre el Centro Comercial. Una sociedad que ha girado hacia el logro material en términos de culto, ocasionando creciente valor significante del consumo. Razón última de la humanidad al decir de Rem Koolhaas. Culto que desemboca en la urgencia de alcanzar niveles de estatus y de identificación con el grupo. Dos parámetros que marcan la relación con el otro. Relación de comparación que excita la necesidad de posesión de objetos que llevaban a recrear en el consumidor la ilusión de ser especiales, de no pasar desapercibidos. El producto de consumo, el objeto, se eleva a la consideración de valor social. En el Centro Comercial se venden valores. Marketing de valores. El deseo del individuo, no la necesidad, queda involucrado en el proceso. La oportunidad y el interés de este estudio surgen además para aclarar el significado de un espacio que sirve al consumidor y a su entorno. Un significado que alcanza sentido, entre otros, por la aparición de un nuevo contexto tras la Segunda Guerra Mundial. Suburbanización, automóvil, nivel de vida, un nuevo papel de la mujer. La Era del Consumo. Una era que genera la paradoja de un individuo con autodeterminación y autosuficiencia crecientes, en un mundo cada vez más condicionado y controlado por dinámicas de ofertas mediatizadas e ilimitadas. La arquitectura en este contexto ha de juzgarse por su relación con un hombre contemporáneo que camina hacia una progresiva excepcionalidad. Cerramos la presentación justificando el término ignorada que aparece en el Título de la Tesis. Subrayamos la escasa existencia de estudios estructurados que relacionen Centro Comercial y arquitectura. Realidad que se constata partiendo del libro de Pevsner, Historia de las Tipologías Arquitectónicas, de 1976. Analizamos también la aceptación que el Centro Comercial, valorado en algunos ámbitos como arquitectura populista. Primer Capítulo, los antecedentes. Se propone un recorrido histórico por la arquitectura comercial de todos los tiempos. El Documento busca concretar las características de la arquitectura comercial a lo largo de la historia para determinar relaciones entre ella y el Centro Comercial. Estas correspondencias van a permitir contestar la pregunta retórica que nos hacemos al inicio del Capítulo: ¿Es la arquitectura del Centro Comercial una arquitectura subsidiaria, o tiene personalidad propia independiente de la del mundo comercial? Con Zevi40, queremos dejar constancia que la relación arquitectura-historia es imprescindible en la tarea proyectual. Un análisis novedoso solo es posible desde la búsqueda de unas raíces auténticas. Así mismo, con Guy de Maupassant, estamos convencidos que “La arquitectura, a través de los siglos, ha tenido el privilegio de dar un símbolo a cada una de las épocas, de resumir con un pequeñísimo número de monumentos típicos, el modo de pensar, de soñar de una raza y de una civilización”. Este recorrido se inicia interpretando la arquitectura comercial minoica. Llegaremos, paso a paso, hasta el siglo XX, los grandes itinerarios comerciales y el Centro Comercial. Se descubren una serie de invariantes que permiten comparar y extraer conclusiones. Resulta novedoso constatar que el Centro Comercial nace para dar respuesta al hombre contemporáneo en su afán consumista. También lo es la rápida implantación y evolución del Centro Comercial en un corto periodo de sesenta años frente al ritmo sosegado de otras soluciones comerciales. Novedad es ver como el comercio y sus arquitecturas nacen abiertos, bajo tenderetes y el Centro Comercial se presenta cerrado. Así mismo, las referencias sacras constituyen un elemento de novedad para la reflexión, en un contexto materialista. Y tantas otras. En Minos, la óptica comercial ofrece otra visión de su legendaria cultura. ¿Palacio o plataforma logística?, gestión centralizada del intercambio, ¿vida pública y vida privada? Así, hasta llegar al siglo XIX. Sus las galerías y sus pasajes acristalados concebidos en primera instancia como medida de recomposición urbana. Espacio entendido desde lo público-privado, desde lo interior-exterior, desde el dentro-afuera, desde lo cerrado-abierto. Con los nuevos mercados de abastos, representan una revolución en el ámbito de la funcionalidad, de la máquina, de la gestión moderna y de las relaciones del ciudadano con la ciudad apoyado en base al intercambio de bienes de consumo. El Centro Comercial es heredero de esta transformación. El Gran Almacén, por otra parte, es el reflejo de otra gran revolución. La que va ligada a la producción y comercialización en masa, las comunicaciones, el precio fijo y el aumento del nivel de vida. El Centro Comercial reinterpreta estas situaciones insertándolas en un nuevo modelo de gestión. En el siglo XX, maestro en técnicas de venta, aparece el hipermercado. El Híper, con su carga de pedagogía, se incorpora al esquema orgánico del Centro Comercial. La tienda en si misma constituye la pieza base de dicho puzle orgánico. Es en esta época cuando la tienda empieza su despegue autónomo como arquitectura, aportando su experiencia. Tras ello, llegamos a las grandes rutas comerciales, que proponemos como metáfora del shopping. Cerramos el capítulo concluyendo con Eugenio Ferrer que “si establecemos una relación entre el espacio y el capitalismo, entonces podemos inferir que los espacios del consumo de masas (ECM) son configuraciones nuevas respecto al pasado (...), pero el sistema que lo introduce no lo es del todo”. Segundo Capítulo. Búsqueda de claves que permitan el reconocimiento del Centro Comercial. Llegados a este punto y con la perspectiva del tiempo cabe preguntarnos, ¿qué entendemos pues por Centro Comercial? ¿Cómo lo percibimos? Abordamos ahora el problema de la percepción del Centro Comercial y su significado. Además de constituirse en símbolo, referencia siempre presente, la eficacia del Shopping es una de las principales causas de su poder de atracción. El Centro Comercial resulta de la síntesis de la revolución del consumo y de la revolución de la gestión. Espacio eficaz del entretenimiento como destino. El usuario resuelve su vida cotidiana dentro de un hábitat que considera propio y que se entiende como el lugar hiperbólico de la transacción comercial. Espacio de la abundancia para el disfrute. Una arquitectura involucrada en esta eficacia. Su sentido del lugar no es otro que el Shopping, que se desenvuelve de forma análoga en todas partes. El hogar del consumidor. Las nuevas catedrales. Las catedrales del consumo. Destino místico. Lugar de peregrinación para el consumidor fervoroso. Espacio sagrado que integra al usuario en la cultura dominante. Cultura del consumo. Templos, donde el tiempo ha perdido su sentido. Paraíso. Un espacio donde la altura, la luz natural, la dimensión general refuerzan el carácter sacro de un espacio para una nueva religión laica. Un espacio seguro, protegido que nos acerca a ideas como la de útero materno, con su carga de calidez y de significación erótica aplicado al encuentro compra-comprador y, ligado a ello, la literatura especializada habla del Centro Comercial como nave espacial hiperesterilizada o de agujero negro que absorbe la energía cultural. Más allá, la simulación, donde se percibe un simulacro de ciudad. Simulacro coherente con todo lo que el Shopping desencadena a su alrededor. El lugar de los sueños, de la fantasía. Aquí los productos se han metamorfoseado en fetiches, en significados. Televisión tridimensional, donde el usuario actúa guiado por una pulsión similar al zapping. Espacio lúdico de la fascinación por comprar o de imaginar que se compra. Espacio de simulaciones que llevan a la ensoñación. Un nuevo lugar que sustituye al espacio cotidiano, con el señuelo de la protección, en un contexto imaginariamente público. Espacio de la hiperrealidad donde no se distingue la realidad de la fantasía, donde tras episodios de confusión y desconcierto, se borran las fronteras con lo imaginario. Espacio mágico, escenario del gran espectáculo del consumo, controlado milimétricamente, al modo de la visita a un gran monumento, que ha de sobrevivir a los tiempos para dar testimonio de nuestro momento. Un icono, un símbolo que transmite un mensaje, que solo el consumidor es capaz de interpretar. Una agitada mezcla, sin precedentes, de percepciones que hablan de perplejidad y asombro ante el fenómeno del Centro Comercial, su espacio y las reacciones del hombre contemporáneo. ¿Cuáles serían las claves que nos permitirían reconocer la calidad esencial de un Centro Comercial, en esta concurrencia de perplejidades? Primero, la función de servicio. Un espacio donde ocurren muchas más cosas que lo obvio, que la compra. Un edificio que se involucra con el entorno de la mano de lo inesperado, la sorpresa y las expectativas. Esta vocación de servicio conecta Centro Comercial y naturaleza arquitectónica. Función que sugiere percepciones ligadas a la experiencia de compra. Organismo que vive y late al unísono con su visitante, colocándose al servicio de sus necesidades, de su afán de consumo, del que vive. Segundo, la comunidad servida. El Centro comercial sirve a una sociedad concreta. La sociedad consumista. Una nueva sociedad que se identifica con el edificio desarrollando un sentido de comunidad al nivel de sus deseos. Esta comunidad que se configura a su alrededor, constituye el activo más poderoso para el éxito de su realidad cotidiana y de su futuro. Tercero, un compromiso de carácter holístico. La economía de la experiencia aplicada al afán consumista de una sociedad identificada con su Centro, da lugar a una experiencia holística planificada. Diseño emocional. Colaboración para el éxito de un conjunto de establecimientos comerciales que participan en la aventura espacio-comercial del Centro Comercial. Ellos son los inductores primarios del consumo. Pero esta colaboración tiene su culminación en la amplificación del mensaje, como un inmenso altavoz, que proviene de la unidad configurada por todos ellos. El reflejo de esta amplificación de mensajes, desde la poderosa unidad constituida, es el aumento de la rentabilidad, fin último de la operación. Cuarto, la forma a través de una identificación de carácter gestáltico. Desde la lectura gestáltica que hacemos de la unidad holística, se advierte una poderosa capacidad de comunicación del sistema con su contexto. Centro y entorno se tornan entonces cómplices que complementan sus realidades. El Centro Comercial, arquitectura estructurada como sistema se percibe –ha de percibirse- como forma unitaria que procede de una mirada de raíz gestáltica que continuamente la recompone desde una óptica espacial y física, ligada a la experiencia individual. Esta unidad formal, más allá de la forma real, se constituye en esencia de de su arquitectura. Quinto, el Centro Comercial como sistema. Un sistema soportado por la Teoría General de Sistemas. La consideración del Centro Comercial como sistema es consecuencia de su estructura holística. El todo no se comporta como la suma de las partes y estas no lo hacen como lo harían en solitario. De aquí surge la necesidad de diálogo permanente entre la comercialización –proceso de incorporación de partes- y su traducción al mundo del diseño –proceso de articular arquitectónicamente las partes. Como sistema así configurado, el Centro Comercial se inserta en el paradigma contemporáneo, lo que genera realidades duales que no son excluyentes y reacciones de perplejidad e incertidumbre que el sistema corrige con su capacidad de autorregulación. Aparece también el espectador cuántico, el visitante, el consumidor, que interactúa con el sistema. Desde las herramientas que nos aporta la idea de sistema complejo, afrontamos el Mix Comercial -en definitiva la eficaz localización de las piezas en orden a sus relaciones y al organismo resultante- y su incidencia en la arquitectura que estamos concibiendo. Una arquitectura impredecible por lo mutable, que se erige en reto de la operación y del diseñador. Diseño que, de la mano del concepto de sistema se convierte en herramienta a mayor gloria de la operación global. El debate del estilismo no será más que el resultado del análisis en busca del éxito de esta operación. Sexto, una arquitectura de la negociación. Negociación como mecanismo proyectual y como resultado. La solución de proyecto nunca resulta evidente en el Centro Comercial como consecuencia de lo imprevisible del propio proceso de configuración. Su concreción solo puede ser fruto del compromiso de todos los agentes por conseguir el objetivo de la operación. Esto se consigue desde el equilibrio de intereses. Comerciales y de diseño. Un compromiso con la negociación y una negociación íntimamente ligada a la coordinación. Séptimo, el espacio y el tiempo. El debate espacio-tiempo condiciona y estructura la percepción del Centro Comercial. Introducimos conceptos como cronotopo –el instante y el lugar donde ocurre algo- y paradoja –incoherencia de la relación causa efecto- que sitúan el vínculo entre el tiempo y el espacio del Centro Comercial en un contexto de Shopping. En el discurrir paralelo del tiempo histórico –el tiempo de fuera- y del tiempo interior, el de dentro del Centro Comercial –tiempo presente o intemporalidad-, se produce el triunfo social del Centro Comercial que se traduce en haber sabido resolver en el espacio y en el tiempo las paradojas postmodernas del hombre contemporáneo. Octavo, de lo global. Globalidad que no es ajena a lo local. Una arquitectura que insertada en la dinámica de una economía de ámbito mundial, refleja las contradicciones que ella impone, fundamentalmente en los procesos de inclusión y exclusión, afectando de manera decisiva al debate de lo local, que el Centro Comercial debe incorporar como herramienta ineludible de reconocimiento. Terminamos el capítulo segundo manifestando como estas ocho claves, asumidas en su conjunto, confirman que el Centro Comercial puede aparecer como un todo conceptual cohesionado, pasando a formar parte de una familia arquitectónica coherente, cuya estructura funcional somos capaces de establecer. El Capítulo Tercero presenta con detalle la figura del arquitecto Víctor Gruen, creador reconocido del moderno Centro Comercial. Presentamos su trayectoria profesional observando como las diferentes claves analizadas en capítulos anteriores van apareciendo de manera natural a lo largo de ella "Victor Gruen may well have been the most influential architect of the twentieth century." Malcolm Gladwell. The Terrazo Jungle. Fifty Years Ago, The Mall Was Born. America Never Would Be The Same. 2004. In The New Yorker. Hombre complejo, conflictivo. Las paradojas a lo largo de su carrera fueron notables. Sin embargo siempre apareció como un hombre recto. Garret Eckbo, reconocido paisajista y colaborador de Gruen en el Centro Comercial peatonal del Centro urbano de Fresno, California, se asombraba de que alguien como Gruen hubiese sido capaz de combinar cortesía y humanidad en la carrera de ratas (sic) en la que se convirtió el universo de la comercialización americana y mantener la integridad542. Philip Johnson, en 1962, ponderando las muchas habilidades de Gruen manifestó que no estaba seguro si alguno de ellos, arquitectos artistas, hubiera sido capaz de hacer lo que Gruen hizo. A más, sobre Gruen, manifestó lo siguiente: "... El va más allá de la creación de un bello edificio. En jugar con la gente y sugerir lo que tienen que hacer, es un maestro. Y obtiene buenos resultados como hace la escultura. El suyo es un arte cívico, un sentido cívico.... Él es capaz de sentarse y poner cosas juntas. No es pomposo ni vano. Yo no me reuniría con él para hablar del diseño (de edificios). Víctor siente que cuando se habla de diseño se está ignorando todo el contexto... Su arquitectura es poderosamente limpia, no vuela la fantasía. Pero cuando te haces con su complejidad, ves que has descubierto algo más allá del diseño.... No puedes decir que haya alguien como él. La arquitectura tiene la suerte de tenerle como arquitecto..." Philip Johnson. Article in Fortune Review. 1962. El Documento de tesis cierra la visión de Gruen realizando un recorrido por los diferentes capítulos de su libro esencial, Shopping Towns Usa: The Planning of Shopping Centers. Solo su índice resulta un monumento al proceso de gestación del Centro Comercial. El libro, aquí simplemente mostrado en su estructura básica como un silencioso testigo, es la referencia canónica los Centros Comerciales contemporáneos, desde su aparición. . El Cuarto Capítulo del Documento de tesis es una recapitulación del trabajo anterior, en el que se sintetizan los conceptos de función y estilo relacionados con el Centro Comercial, se define en qué consiste cada uno de ellos y como, a partir de ahí, podemos afirmar que nos encontramos ante un tipo arquitectónico nuevo en el panorama de la disciplina arquitectónica. Terminamos el Capítulo integrando el Centro Comercial con un cuerpo teórico de referencias que se remiten a un tipo arquitectónico concreto y particular, acogiendo su singularidad como fenómeno arquitectónico autónomo. Como Conclusión de la tesis, resultado de todo lo anterior es decir, como consecuencia de la integración de un torrente de percepciones e intuiciones en un cuerpo teórico de referencias, deducidas de la existencia de unas claves que estructuran y penetran la esencia del singular modelo estudiado, haciéndolo detectable y seductor, resultan las características de un tipo arquitectónico con entidad propia que ordena, orienta y supedita la realidad y la existencia de esta nueva arquitectura. Una arquitectura nunca antes definida como tal, en el panorama tipológico de la disciplina. Teoría tipológica para una nueva arquitectura, que hemos ido proponiendo a lo largo del trabajo y que es coherente con los diferentes parámetros que se han analizado. Un conjunto edificado que, desde el estudio de sus claves esenciales y de sus invariantes perceptibles, aparece ahora más cercano, más familiar. Tanto que es posible destilar desde este conocimiento cercano e íntimo, una síntesis útil como referencia proyectual y como referencia para las grandes cuestiones que preocupan al discurrir del debate arquitectónico y sus ideas. El debate de la disciplina. El objeto de esta tesis, que consistía en establecer que el conjunto edificado que conocemos como Centro Comercial se constituye en un nuevo tipo en el panorama de las tipologías arquitectónicas, entendido el Centro Comercial en sentido genérico como familia arquitectónica con características propias y específicas que la hacen autónoma y reconocible, queda a nuestro juicio argumentado y justificado. ABSTRACT Within the frame of the built heritage there is a construction that is recognized as Shopping Center. An ensemble understood as an architectural family with its own specific recognizable characteristics. This thesis aims to explain that this building complex constitutes a new type in the panorama of architectural typology. This typology, with its singular identity, is connected to a way of understanding the idea of the model beyond an orthodox conception of the term understood as virtual model. This typology comes from a theoretical structure that we called typological theory, and it serves as yet another tool to reference the study and development design of the architectural spaces. In this first section, the Method, we emotionally explore the opportunities of this thesis. Why this typology has been ignored and the interest this work has in the present moment. An opportunity and an interest explained from an experience of a life dedicated to the world of Shopping Centers. The text then introduces the need for a rigorous knowledge of the Shopping Center’s essence in order to understand its impact in the frame of a new society and a new physical environment. A frame time where the historical mechanisms of association of civic community have given way to other gathering spaces like the Shopping Center, which encourages individualism, but is demanded by a society that relates to them. Spaces that, according to Galbraith, are a result of the intrinsic perversity of the unstoppable movement of the wheel of consumption-production. A society that has turned to worship of material achievement. Worship that provokes the appearance of an increasing value of consumption, according to Koolhaas, the only goal of humanity. Worship that ends in the need to reach certain status levels in the plane of a permanent comparison where the need of possession excites the consumer and gives them the illusion of being special. The product of consumption rises up to consideration of social values, entering a dynamic of marketing values, not only objects, but the desire of the individual remains. The study appears also to clarify the meaning of a space that serves the consumer and its context. A meaning that makes sense with the appearance of the suburbanization, the massive utilization of the car, the increase of living standards and the new role of women in the society after the Second World War, giving rise to the Age of Consumption. A world now determined and controlled by media and unlimited offers, where it’s necessary to place them in the context of the ordinary. An architecture that has to be judged precisely for its relation with this specific contemporary man. This section ends justifying the term ignored that appears in the Title of the Thesis, considering it in relation with the lack of studies structured about the Shopping Center and its architecture, drawing from Pevsner's work, A history of building types, 1976. Finally, the Shopping Center is analyzed with the most critical of thoughts, which considers it as populist architecture. The First Chapter, Precedents, proposes an historical tour of the commercial architecture throughout history. The Document looks to place on record the characteristics of the commercial architecture to set the connection between them and the Mall itself. These correspondences are going to allow us to answer the rhetorical question: is it the architecture of the Shopping Center a subsidiary architecture, or does it have its own personality independent from that of the commercial world? The reason of this historical search, citing Bruno Zevi, is that it is indispensable to establish the relationship between architecture and history, understating that an analysis is only possible when researching for their roots. Moreover, according to Guy de Maupassant, we are sure that architecture has had the privilege, across the centuries, of symbolizing as it were each age(…), through the harmony of lines and the charm of ornamentation all the grace and grandeur of an epoch. This historical reading, inseparable from a consistent design action, begins interpreting the commercial architecture of the Minoan to the 20th Century. Though this analysis of the big commercial itineraries and the study of the Shopping Center itself. A reading where we have found a series of constants that make it possible to draw conclusions from this comparison. The Mall appears to give response to the needs of a consumerist society. Comparing to the calm pace of the evolution of other commercial solutions, it is relevant its fast implantation and evolution in a short period of sixty years. Though via different solutions, the commercial spaces are considered taking into account the public-private relation, the interior-exterior, the inside-out, the closed-opened. Through that, the 19th century galleries and the food markets represent a revolution in functionality, in the machine, the modern management and the relations of the citizen within the city. All of this, the Mall inheritor feels. Likewise, the Department Store is the reflection of another great revolution. Production and commercialization en-mass, communications, the fixed price and increase of the living standard. The Mall reinterprets these situations inserting them in a new model of management. Already in the 20th century Mall and mass technologies of sale, the hypermarket is enthusiastically incorporated into the configuration of this organic scheme, constituting the base of one of the models, the French, that will be highly developed in the European continent. The shop itself constitutes, on the other hand, the key piece that completes the puzzle of the Mall and is in this epoch when it starts taking off as architecture, has an autonomous character. After all this, finally, we come to the big commercial routes, which we propose as metaphor of the shopping. Citing Eugenio Ferrer we can conclude that “If we establish a relation between the space and the capitalism, then we can infer that the spaces of the consumption of masses (ECM) are new configurations with regard to the past (...), but the system that introduces it it is not completely” Now we arrive at this point and with the perspective of time it is necessary to ask us, what do we understand about the Shopping Center? How do we perceive it? The second Chapter approaches the problem of the perception of the Mall and from this it is possible to detect and to identify key drivers that orientate the architectural comprehension of the space. The efficiency of the Shopping Center is its main power of attraction. A world that has ensued from the synthesis of the revolution of consumption and management. An effective cavern-like place of entertainment where the user, the consumer, the postmodern man solves his daily life inside a considered habitat. The hyperbolic place of commercial transaction. An abundance of space, that makes us perceive it as destination of entertainment. An architecture has evolved this efficiency, where the sense of place is at one with the sense of the Shopping. The home of the consumer. The new cathedrals. The cathedral of consumption. The place of peregrination for the fervent consumer. A sacred space that integrates the user in the dominant culture. A temple, where time itself has stopped existing. In this paroxysm, an expression of the Garden of Eden or Paradise itself. A space where the height, the natural daylight and the spatial dimension reinforce the sacred character of a new lay religion. Another common perception is that of a protected area, which leads to metaphors and considerations that suggest the idea of maternal womb, with its weight of erotic meaning, referring to the encounter of the shopper making a purchase. The literature also tells us about its perception as a sterile space capsule, a black hole that absorbs all cultural energy. Likewise, a world simulation where a mock city is perceived at first instance. Consistent with all that shopping triggers inside. A city, a space conceived as a place of dreams, fantasy, where the products have been metamorphosed into fetishes. Entertaining a television, three-dimensional television, where the user acts guided by a drive similar to zapping. A play area where the latest fascination is in the act of buying. Space simulations that unite and transcend creating atmospheres that lead to reverie. A new space replacing the daily space with the lure of safe space in a public context. A hyper-reality space with reality and fantasy, where borders are erased with imaginary episodes of confusion and bewilderment, without distinction. The charm and fascination of a space that reads like magic. The magic of a space which is defined as stage extravaganza, the large theatre, the consumer surveys in the fine control mode in which you visit a national monument. The shopping center has to survive the times to be a testimony of our time. An icon, a symbol that conveys a message, the message reads ‘consumer’. In short, a Shopping Center is a mix of unprecedented insights that speak of a widespread phenomenon of bewilderment. Its space and the reactions of contemporary man unfold in it like a fish in water. What are the key aspects which allow us to recognize the essential quality of a shopping center in this concurrence of perplexities? First, we want to record a service function of space much deeper than the immediately obvious, i.e. a purchase occurs. A building that appears to be involved with the environment and its people from the hand of the unexpected circumstances; surprise and attention. And that, in turn, also involves the visitor beyond the purchase. This dedication to service closely links the mall with its architectural nature. It is not the function of a lifeless machine. It is a feature that suggests unsuspected perceptions linked to the purchase, which speaks of an organism that lives and breathes in unison with the visitor. Second, in addition to the vocation of service-oriented desire for consumption, the Mall environment serves a particular society - The consumer society. A new society which relates to building a sense of community developed to the level of their desires. This community also constitutes the most powerful asset to the success of the daily life of the Shopping Center. Third, we emphasize that the so called economy of the experience is combined with the consumer zeal of a company that is identified by the Shopping Center. It connects to form a holistic and planned experience. This experience takes shape in the entity that ensues from the premeditated association and synergy, in the sense of a collaboration for success. A set of concrete commercial and independent establishments, take part in the spatial and commercial adventure that is the Mall and they are the instigators of the consumption. This holistic behavior finds culmination in the amplification of a claim that becomes unitary, like an immense force that leads to an increased profitability to all the levels. Consummation is a reference of one human being overturned in an architecture assimilated into a legitimate, emotional design with stability. A holistic quality is born of the essence of the building - and by virtue of the Conditions of Alexander, Christopher Alexander, determines the system condition of the Shopping Center. Fourth, we propose to establish what character the Mall will form when joined with the concept of its typology. This is going to allow the architectural work to be formed. As a result of the holistic structure that we see, the Mall is perceived as a system whose parts have their own function, justifying their existence in the ecosystem. Across a gestalt there is a powerful capacity of communication between the system and its context. We visualize on the one that stands out our building, turning both, Center and environment, in accomplices of a few special relations who complement each other in his realities. This relationship within a complex and diverse environment gives the Mall a range of unique spatial perceptions, the result of disparate experiences, which because of its root origin of gestalt, are integrated into a unified and coordinated manner fully intelligible and organized. This is the final formal essence of the Shopping Center. We can conclude here that the Mall as architecture is a structured system and should be perceived as a unit both from a physical and spatial perspective as this is the essence of its architecture. Fifth, the Mall as a system. A system which is being supported by a broad theoretical corpus, the General Systems Theory, which offers sufficient methodology to descend into consideration and give an enlightened conclusion on the overall understanding of the Mall. Consideration of the Mall as a system is a result of its holistic structure. The whole does not behave like any of the parties and they do not behave the way they used to before belonging to the whole, because they inhibit many of their qualities to their advantage. It arises the need for an ongoing dialogue between marketing processes and its translation into the physical world, the design. The system generates multiple perceptions to be integrated into a body which is to be understood as unitary. As a system, the Mall is inserted into the contemporary paradigm, creating dual realities that are not exclusive and are reactions of uncertainty that the system be properly designed at all levels, faced with their ability to self-regulate. Likewise, considering the visitor, the customer, like the quantum spectator who interacts with the system permanently. Moreover, a complex system confronts us with the Commercial mix, the effective location of parts in order to relate to the body and its importance in the architecture we are conceiving. Unpredictable architecture, which stands as the challenge of the operation and the designer. Design that becomes the tool of the system to create success for the overall operation. The discussion of the styling is merely the result of analysis that also seeks the success of the system, i.e. the styling should send the right message for the environment to ensure its survival. Sixth, the idea of negotiation as an architecture project, a mechanism inherent to the status of the proposed system. The project solution is never evident at the Shopping Center because of the unpredictability of the process itself. It can only be the fruit of the commitment of all stakeholders to achieve the objective of the operation. This is achieved from the balance of interests, of commercial and design. A commitment to negotiation and a negotiation linked to coordination. The pursuit of stability is key, as instability is always present and constantly requires strategies to build the object you are configuring. Seventh, proposes space-time itself as a circumstance that determines and structures the perception of the Mall in a singular way. We introduce concepts as chronotope and paradox to help us place the relationship between time and space within the Mall in the context of shopping. A consequence of the parallel flow of historical time - the time outside - and the time inside the Mall, the big shopping center formula is precisely that of having the feeling of timelessness in the space. The social triumph of the mall is the ability to resolve in space and in time all postmodern paradoxes and, beyond that, of contemporary man, condensing into a small space and time an enormous amount of cultural symbols, often contradictory, but they attract the practice of consumerism. Eighth, global level. Globalization which doesn’t ignore the local level. Architecture that is inserted into the dynamics of a global economy, reflects the contradictions that it imposes, mainly in the processes of inclusion and exclusion. Inclusion and exclusion affect the debate of the local level, which the Mall must incorporate as an unavoidable tool of recognition. The eight fundamental principles, when applied as a whole, confirm that the built heritage, which corresponds to the general Mall idea, can be presented as a cohesive conceptual whole. This becomes part of a coherent architectural family, whose functional structures are able to be established. The Third chapter presents in a detailed way the figure of the architect Victor Gruen, recognized as the creator of the modern Mall. Studying his professional experience, it is shown how the different keys analyzed in previous chapters are appearing in a natural way. "Victor Gruen may well have been the most influential architect of the twentieth century." Malcolm Gladwell. The Terrazo Jungle. Fifty Years Ago, The Mall Was Born. America Never Would Be The Same. 2004. In The New Yorker. He was a complex, troubled man and the paradoxes along his career were notable. Nevertheless, always he appeared as a straight man. Garret Eckbo, the recognized landscape painter and collaborator of Gruen was astonished how Gruen had been capable of combining comity and humanity in this career of rates, into that the American commercialization turned, Johnson, in 1962, weighting many Gruen's skills demonstrated that he was not sure if anyone of them, architects artists, had been capable of doing what Gruen did. He goes beyond just the creation of a beautiful building. In playing on people and suggesting what they ought to do, he is a master. (…) his architecture is clean - hardly architecture, no flights of fancy. But when you get hold of its complexity, you've got something beyond the design... You can't say there's someone like him. Architecture is lucky to have him as an architect." Philip Johnson. Article in Fortune Review. 1962. The Document of the thesis closes with Gruen's vision of realizing a tour through the different chapters of his essential book, Shopping towns USA: The Planning of Shopping Centers. It’s mere index turns out to be a monument to the process of the gestation of the Mall. The book, simply acted in its basic structure as a silent witness, as the canonical reference for the contemporary Malls. The Fourth Chapter of the Document of the thesis is a recapitulation of the previous work, which synthesizes the concepts of function and style related to the Shopping Center, and clearly defines how they are defined so we can conclude that we have found an architectural new type in the panorama of the architectural discipline. Therefore, the Conclusion of the thesis integrates this development in a theoretical body of references that relate to an architectural specific and particular type, which receives the singularity of the Shopping Center as an architectural independent phenomenon as it has tried to demonstrate from the beginning of the work. To conclude, as a result of the integrative process and the development of the theoretical body of references, the essential characteristics of the order and concept of the architectural typology form the existence of a new architecture; architecture never before defined as such, in the theoretical typology of the discipline. A theoretical typology for a new architecture is proposed throughout the discussed research and forms a conclusion of the different parameters that have been analysed. As a building complex, from the study of the essential characteristics and of the perceptible constants, the typology is more clearly defined and thus, becomes a useful tool and precedent for the consideration of the discipline. The thesis then justifies how the building complex known as Shopping Center constitutes a new type of architectural typology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El uso de aritmética de punto fijo es una opción de diseño muy extendida en sistemas con fuertes restricciones de área, consumo o rendimiento. Para producir implementaciones donde los costes se minimicen sin impactar negativamente en la precisión de los resultados debemos llevar a cabo una asignación cuidadosa de anchuras de palabra. Encontrar la combinación óptima de anchuras de palabra en coma fija para un sistema dado es un problema combinatorio NP-hard al que los diseñadores dedican entre el 25 y el 50 % del ciclo de diseño. Las plataformas hardware reconfigurables, como son las FPGAs, también se benefician de las ventajas que ofrece la aritmética de coma fija, ya que éstas compensan las frecuencias de reloj más bajas y el uso más ineficiente del hardware que hacen estas plataformas respecto a los ASICs. A medida que las FPGAs se popularizan para su uso en computación científica los diseños aumentan de tamaño y complejidad hasta llegar al punto en que no pueden ser manejados eficientemente por las técnicas actuales de modelado de señal y ruido de cuantificación y de optimización de anchura de palabra. En esta Tesis Doctoral exploramos distintos aspectos del problema de la cuantificación y presentamos nuevas metodologías para cada uno de ellos: Las técnicas basadas en extensiones de intervalos han permitido obtener modelos de propagación de señal y ruido de cuantificación muy precisos en sistemas con operaciones no lineales. Nosotros llevamos esta aproximación un paso más allá introduciendo elementos de Multi-Element Generalized Polynomial Chaos (ME-gPC) y combinándolos con una técnica moderna basada en Modified Affine Arithmetic (MAA) estadístico para así modelar sistemas que contienen estructuras de control de flujo. Nuestra metodología genera los distintos caminos de ejecución automáticamente, determina las regiones del dominio de entrada que ejercitarán cada uno de ellos y extrae los momentos estadísticos del sistema a partir de dichas soluciones parciales. Utilizamos esta técnica para estimar tanto el rango dinámico como el ruido de redondeo en sistemas con las ya mencionadas estructuras de control de flujo y mostramos la precisión de nuestra aproximación, que en determinados casos de uso con operadores no lineales llega a tener tan solo una desviación del 0.04% con respecto a los valores de referencia obtenidos mediante simulación. Un inconveniente conocido de las técnicas basadas en extensiones de intervalos es la explosión combinacional de términos a medida que el tamaño de los sistemas a estudiar crece, lo cual conlleva problemas de escalabilidad. Para afrontar este problema presen tamos una técnica de inyección de ruidos agrupados que hace grupos con las señales del sistema, introduce las fuentes de ruido para cada uno de los grupos por separado y finalmente combina los resultados de cada uno de ellos. De esta forma, el número de fuentes de ruido queda controlado en cada momento y, debido a ello, la explosión combinatoria se minimiza. También presentamos un algoritmo de particionado multi-vía destinado a minimizar la desviación de los resultados a causa de la pérdida de correlación entre términos de ruido con el objetivo de mantener los resultados tan precisos como sea posible. La presente Tesis Doctoral también aborda el desarrollo de metodologías de optimización de anchura de palabra basadas en simulaciones de Monte-Cario que se ejecuten en tiempos razonables. Para ello presentamos dos nuevas técnicas que exploran la reducción del tiempo de ejecución desde distintos ángulos: En primer lugar, el método interpolativo aplica un interpolador sencillo pero preciso para estimar la sensibilidad de cada señal, y que es usado después durante la etapa de optimización. En segundo lugar, el método incremental gira en torno al hecho de que, aunque es estrictamente necesario mantener un intervalo de confianza dado para los resultados finales de nuestra búsqueda, podemos emplear niveles de confianza más relajados, lo cual deriva en un menor número de pruebas por simulación, en las etapas iniciales de la búsqueda, cuando todavía estamos lejos de las soluciones optimizadas. Mediante estas dos aproximaciones demostramos que podemos acelerar el tiempo de ejecución de los algoritmos clásicos de búsqueda voraz en factores de hasta x240 para problemas de tamaño pequeño/mediano. Finalmente, este libro presenta HOPLITE, una infraestructura de cuantificación automatizada, flexible y modular que incluye la implementación de las técnicas anteriores y se proporciona de forma pública. Su objetivo es ofrecer a desabolladores e investigadores un entorno común para prototipar y verificar nuevas metodologías de cuantificación de forma sencilla. Describimos el flujo de trabajo, justificamos las decisiones de diseño tomadas, explicamos su API pública y hacemos una demostración paso a paso de su funcionamiento. Además mostramos, a través de un ejemplo sencillo, la forma en que conectar nuevas extensiones a la herramienta con las interfaces ya existentes para poder así expandir y mejorar las capacidades de HOPLITE. ABSTRACT Using fixed-point arithmetic is one of the most common design choices for systems where area, power or throughput are heavily constrained. In order to produce implementations where the cost is minimized without negatively impacting the accuracy of the results, a careful assignment of word-lengths is required. The problem of finding the optimal combination of fixed-point word-lengths for a given system is a combinatorial NP-hard problem to which developers devote between 25 and 50% of the design-cycle time. Reconfigurable hardware platforms such as FPGAs also benefit of the advantages of fixed-point arithmetic, as it compensates for the slower clock frequencies and less efficient area utilization of the hardware platform with respect to ASICs. As FPGAs become commonly used for scientific computation, designs constantly grow larger and more complex, up to the point where they cannot be handled efficiently by current signal and quantization noise modelling and word-length optimization methodologies. In this Ph.D. Thesis we explore different aspects of the quantization problem and we present new methodologies for each of them: The techniques based on extensions of intervals have allowed to obtain accurate models of the signal and quantization noise propagation in systems with non-linear operations. We take this approach a step further by introducing elements of MultiElement Generalized Polynomial Chaos (ME-gPC) and combining them with an stateof- the-art Statistical Modified Affine Arithmetic (MAA) based methodology in order to model systems that contain control-flow structures. Our methodology produces the different execution paths automatically, determines the regions of the input domain that will exercise them, and extracts the system statistical moments from the partial results. We use this technique to estimate both the dynamic range and the round-off noise in systems with the aforementioned control-flow structures. We show the good accuracy of our approach, which in some case studies with non-linear operators shows a 0.04 % deviation respect to the simulation-based reference values. A known drawback of the techniques based on extensions of intervals is the combinatorial explosion of terms as the size of the targeted systems grows, which leads to scalability problems. To address this issue we present a clustered noise injection technique that groups the signals in the system, introduces the noise terms in each group independently and then combines the results at the end. In this way, the number of noise sources in the system at a given time is controlled and, because of this, the combinato rial explosion is minimized. We also present a multi-way partitioning algorithm aimed at minimizing the deviation of the results due to the loss of correlation between noise terms, in order to keep the results as accurate as possible. This Ph.D. Thesis also covers the development of methodologies for word-length optimization based on Monte-Carlo simulations in reasonable times. We do so by presenting two novel techniques that explore the reduction of the execution times approaching the problem in two different ways: First, the interpolative method applies a simple but precise interpolator to estimate the sensitivity of each signal, which is later used to guide the optimization effort. Second, the incremental method revolves on the fact that, although we strictly need to guarantee a certain confidence level in the simulations for the final results of the optimization process, we can do it with more relaxed levels, which in turn implies using a considerably smaller amount of samples, in the initial stages of the process, when we are still far from the optimized solution. Through these two approaches we demonstrate that the execution time of classical greedy techniques can be accelerated by factors of up to ×240 for small/medium sized problems. Finally, this book introduces HOPLITE, an automated, flexible and modular framework for quantization that includes the implementation of the previous techniques and is provided for public access. The aim is to offer a common ground for developers and researches for prototyping and verifying new techniques for system modelling and word-length optimization easily. We describe its work flow, justifying the taken design decisions, explain its public API and we do a step-by-step demonstration of its execution. We also show, through an example, the way new extensions to the flow should be connected to the existing interfaces in order to expand and improve the capabilities of HOPLITE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research studied the effects of additional fiber in the rearing phase diets on egg production, gastrointestinal tract (GIT) traits, and body measurements of brown egg-laying hens fed diets varying in energy concentration from 17 to 46 wk of age. The experiment was completely randomized with 10 treatments arranged as a 5 × 2 factorial with 5 rearing phase diets and 2 laying phase diets. During the rearing phase, treatments consisted of a control diet based on cereals and soybean meal and 4 additional diets with a combination of 2 fiber sources (cereal straw and sugar beet pulp, SBP) at 2 levels (2 and 4%). During the laying phase, diets differed in energy content (2,650 vs. 2,750 kcal AMEn/kg) but had the same amino acid content per unit of energy. The rearing diet did not affect any production trait except egg production that was lower in birds fed SBP than in birds fed straw (91.6 and 94.1%, respectively; P < 0.05). Laying hens fed the high energy diet had lower feed intake (P < 0.001), better feed conversion (P < 0.01), and greater BW gain (P < 0.05) than hens fed the low energy diet but egg production and egg weight were not affected. At 46 wk of age, none of the GIT traits was affected by previous dietary treatment. At this age, hen BW was positively related with body length (r = 0.500; P < 0.01), tarsus length (r = 0.758; P < 0.001), and body mass index (r = 0.762; P < 0.001) but no effects of type of diet on these traits were detected. In summary, the inclusion of up to 4% of a fiber source in the rearing diets did not affect GIT development of the hens but SBP reduced egg production. An increase in the energy content of the laying phase diet reduced ADFI and improved feed efficiency but did not affect any of the other traits studied.