48 resultados para current controlled voltage-source inverter


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An electrodynamic tether experiment, to be carried out in the Russian spacecraft Almaz, is proposed. A 10 km tether would be deployed downwards; the lower 8 km would be nonconductive, the upper 2 km would be conductive, bare, and 2.2 mm in diameter, and would act as a thruster, with power supply at the top. This hybrid arrangement allows for other, onelectrodynamic experiments,reducing costs; it also limits the induced electromotive force, reducing the power to be handled. The current-voltage characteristic of contactors would be measured. With the anode switched off, the wire itself should collect a current over 5 A at day conditions, providing a thrust of 0.11 N at a 0.77 kW power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been recently suggested that the magnetic field created by the current in a bare tether could sensibly reduce its electron collection capability in the magnetised ionosphere, a region of closed magnetic surfaces disconnecting the cylinder from infinity. In this paper, the ohmic voltage drop along the tether is taken into account in considering self-field effects. Separate analyses are carried out for the thrust and power generation and drag modes of operation, which are affected in different ways. In the power generation and drag modes, bias decreases as current increases along the tether, starting at the anodic, positively-biased end (upper end in the usual, eastward-flying spacecraft); in the thrust mode of operation, bias increases as current increases along the tether, starting at the lower end. When the ohmic voltage drop is considered, self-field effects are shown to be weak, in all cases, for tape tethers, and for circular cross-section tethers just conductive in a thin outer layer. Self-field effects might become important, in the drag case only, for tethers with fully conductive cross sections that are unrealistically heavy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bandwidth achievable by using voltage mode control or current mode control in switch-mode power supply is limited by the switching frequency. Fast transient response requires high switching frequency, although lower switching frequencies could be more suitable for higher efficiency. This paper proposes the use of hysteretic control of the output capacitor $(C_{out})$ current to improve the dynamic response of the buck converter. An external voltage loop is required to accurately regulate the output voltage. The design of the hysteretic loop and the voltage loop are presented. Besides, it is presented a non-invasive current sensor that allows measuring the current in the capacitor. This strategy has been applied for DVS (dynamic voltage scaling) on a 5 MHz buck converter. Experimental results validate the proposed control technique and show fast transient response from 1.5 V to 2.5 V in 2 $mu{rm s}$.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Wearable Power System (WPS) is a portable power source utilized primarily to power the modern soldier’s electronic equipment. Such a system has to satisfy output power demands in the range of 20 W...200 W, specified as a 4-day mission profile and has a weight limit of 4 kg. To meet these demands, an optimization of a WPS, comprising an internal combustion (IC) engine, permanent magnetic three-phase electrical motor/generator, inverter, Li-batteries, DC-DC converters, and controller, is performed in this paper. The mechanical energy extracted from the fuel by IC engine is transferred to the generator that is used to recharge the battery and provide the power to the electrical output load. The main objectives are to select the engine, fuel and battery type, to match the weight of fuel and the number of battery cells, to find the optimal working point of engine and to minimize the system weight. To provide the second output voltage level of 14 VDC, a separate DC-DC converter is connected between the battery and the load, and optimized for the specified mission profile. A prototype of the WPS based on the optimization presented in the paper results in a total system weight of 3.9 kg and fulfils the mission profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BETs is a three-year project financed by the Space Program of the European Commission, aimed at developing an efficient deorbit system that could be carried on board any future satellite launched into Low Earth Orbit (LEO). The operational system involves a conductive tape-tether left bare to establish anodic contact with the ambient plasma as a giant Langmuir probe. As a part of this project, we are carrying out both numerical and experimental approaches to estimate the collected current by the positive part of the tether. This paper deals with experimental measurements performed in the IONospheric Atmosphere Simulator (JONAS) plasma chamber of the Onera-Space Environment Department. The JONAS facility is a 9- m3 vacuum chamber equipped with a plasma source providing drifting plasma simulating LEO conditions in terms of density and temperature. A thin metallic cylinder, simulating the tether, is set inside the chamber and polarized up to 1000 V. The Earth's magnetic field is neutralized inside the chamber. In a first time, tether collected current versus tether polarization is measured for different plasma source energies and densities. In complement, several types of Langmuir probes are used at the same location to allow the extraction of both ion densities and electron parameters by computer modeling (classical Langmuir probe characteristics are not accurate enough in the present situation). These two measurements permit estimation of the discrepancies between the theoretical collection laws, orbital motion limited law in particular, and the experimental data in LEO-like conditions without magnetic fields. In a second time, the spatial variations and the time evolutions of the plasma properties around the tether are investigated. Spherical and emissive Langmuir probes are also used for a more extensive characterization of the plasma in space and time dependent analysis. Results show the ion depletion because of the wake effect and the accumulation of- ions upstream of the tether. In some regimes (at large positive potential), oscillations are observed on the tether collected current and on Langmuir probe collected current in specific sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mission on board a sounding rocket to carry out two bare-tether experiments is proposed: a test of orbital-motion-limited (OML) collection and the proof-of-flight of a technique to determine the (neutral) density vertical profile in the critical E-layer. Since full bias from the motional field will be small (~ 20V), corresponding to a tape 1 km long and V rocket <8 km/s, a power source with a range of supply voltages of few kV would be used. First, the negative terminal of the supply would be connected to the tape, and the positive terminal to a round, conductive boom of length 10 - 20 m; electrons collected by the boom cross the supply into the tape, where they leak out at the rate of ion impact plus secondary emission. Determination of the density profile from measurements of auroral emissions observed from the rocket, as secondaries racing down the magnetic field reach an E-layer footprint, are discussed. Next the positive terminal of the voltage supply is connected to the tape, and the negative terminal to a Hollow Cathode (HC); electrons now collected by the tape cross the supply, and are ejected at the HC. The opposite connections, with current collection operated by tape and boom, and operating on electrons and ions, and through partial switching in the supply, allow testing OML collection in almost all respects it depends on.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several attempts have been carried out to manufacture intermediate band solar cells (IBSC) by means of quantum dot (QD) superlattices. This novel photovoltaic concept allows the collection of a wider range of the sunlight spectrum in order to provide higher cell photocurrent while maintaining the open-circuit voltage (VOC) of the cell. In this work, we analyze InAs/GaAsN QD-IBSCs. In these cells, the dilute nitrogen in the barrier plays an important role for the strain-balance (SB) of the QD layer region that would otherwise create dislocations under the effect of the accumulated strain. The introduction of GaAsN SB layers allows increasing the light absorption in the QD region by multi-stacking more than 100 QD layers. The photo-generated current density (JL) versus VOC was measured under varied concentrated light intensity and temperature. We found that the VOC of the cell at 20 K is limited by the bandgap of the GaAsN barriers, which has important consequences regarding IBSC bandgap engineering that are also discussed in this work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La idea de este proyecto es acercar la imagen de Libertad de Información y su conocida variante Open Source, donde cubriremos en detalle la multitud de puntos que abarca. Está dirigida a todos los usuarios que quieran conocer de primera mano cómo se inició la idea de Libertad Tecnológica hasta sus aplicaciones. No solo para aquellos que quieran emplearla, sino tambien para aquellos que la ya la usan y necesitan recursos para nuevas ideas. De esta forma, nos acercaremos tambien a la idea de libertad que en la tecnología está actualmente en debate. El contenido se estructura siguiendo las siguientes ramas:  Historia, desde sus orígenes hasta el presente.  Economía, ventajas y desventajas de esta libertad.  Problemas legales en distintos niveles  Noticias y actualizaciones de aplicaciones.  Sociedad, entorno a la aceptación y rechazo por los usuarios, ademas de su influencia en la ética, educación e innovación.  Aplicaciones, donde se incluirán la mayoría de las aplicaciones más conocidas en cada una de las ramas de Open Source. ---ABSTRACT---The topic finally chosen in the list of Professional Skills and Issues has been the Freedom of Information and its best known variant Open Source. We will try to cover in detail most of the points that includes history, economics, law, society and the various applications in which it have influenced. It allows all the public to see first-hand the term of Open Source, from its beginnings to applications. Not just for those who want to use it, but for those who already use it and want to find sources and new ideas. It will also get a step closer to the idea of Freedom of Information as currently being debated. The main branches are going to address:  History, from its origins to the present.  Economic, advantages and disadvantages of being free.  Laws, problems in different continents at the legal level.  News, latest in its various applications.  Society, acceptance or rejection by the people, addition to the factors that influence as ethics, education, and arts innovation.  Applications, where most try to include most current applications of each of the variants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este Proyecto Fin de Grado está enmarcado dentro de las actividades del GRyS (Grupo de Redes y Servicios de Próxima Generación) con las Smart Grids. En la investigación actual sobre Smart Grids se pretenden alcanzar los siguientes objetivos: . Integrar fuentes de energías renovables de manera efectiva. . Aumentar la eficiencia en la gestión de la demanda y suministro de forma dinámica. . Reducir las emisiones de CO2 dando prioridad a fuentes de energía verdes. . Concienciar del consumo de energía mediante la monitorización de dispositivos y servicios. . Estimular el desarrollo de un mercado vanguardista de tecnologías energéticamente eficientes con nuevos modelos de negocio. Dentro del contexto de las Smart Grids, el interés del GRyS se extiende básicamente a la creación de middlewares semánticos y tecnologías afines, como las ontologías de servicios y las bases de datos semánticas. El objetivo de este Proyecto Fin de Grado ha sido diseñar y desarrollar una aplicación para dispositivos con sistema operativo Android, que implementa una interfaz gráfica y los métodos necesarios para obtener y representar información de registro de servicios de una plataforma SOA (Service-Oriented Architecture). La aplicación permite: . Representar información relativa a los servicios y dispositivos registrados en una Smart Grid. . Guardar, cargar y compartir por correo electrónico ficheros HTML con la información anterior. . Representar en un mapa la ubicación de los dispositivos. . Representar medidas (voltaje, temperatura, etc.) en tiempo real. . Aplicar filtros por identificador de dispositivo, modelo o fabricante. . Realizar consultas SPARQL a bases de datos semánticas. . Guardar y cagar consultas SPARQL en ficheros de texto almacenados en la tarjeta SD. La aplicación, desarrollada en Java, es de código libre y hace uso de tecnologías estándar y abiertas como HTML, XML, SPARQL y servicios RESTful. Se ha tenido ocasión de probarla con la infraestructura del proyecto europeo e-Gotham (Sustainable-Smart Grid Open System for the Aggregated Control, Monitoring and Management of Energy), en el que participan 17 socios de 5 países: España, Italia, Estonia, Finlandia y Noruega. En esta memoria se detalla el estudio realizado sobre el Estado del arte y las tecnologías utilizadas en el desarrollo del proyecto, la implementación, diseño y arquitectura de la aplicación, así como las pruebas realizadas y los resultados obtenidos. ABSTRACT. This Final Degree Project is framed within the activities of the GRyS (Grupo de Redes y Servicios de Próxima Generación) with the Smart Grids. Current research on Smart Grids aims to achieve the following objectives: . To effectively integrate renewable energy sources. . To increase management efficiency by dynamically matching demand and supply. . To reduce carbon emissions by giving priority to green energy sources. . To raise energy consumption awareness by monitoring products and services. . To stimulate the development of a leading-edge market for energy-efficient technologies with new business models. Within the context of the Smart Grids, the interest of the GRyS basically extends to the creation of semantic middleware and related technologies, such as service ontologies and semantic data bases. The objective of this Final Degree Project has been to design and develop an application for devices with Android operating system, which implements a graphical interface and methods to obtain and represent services registry information in a Service-Oriented Architecture (SOA) platform. The application allows users to: . Represent information related to services and devices registered in a Smart Grid. . Save, load and share HTML files with the above information by email. . Represent the location of devices on a map. . Represent measures (voltage, temperature, etc.) in real time. . Apply filters by device id, model or manufacturer. . SPARQL query semantic database. . Save and load SPARQL queries in text files stored on the SD card. The application, developed in Java, is open source and uses open standards such as HTML, XML, SPARQL and RESTful services technologies. It has been tested in a real environment using the e-Gotham European project infrastructure (Sustainable-Smart Grid Open System for the Aggregated Control, Monitoring and Management of Energy), which is participated by 17 partners from 5 countries: Spain, Italy, Estonia, Finland and Norway. This report details the study on the State of the art and the technologies used in the development of the project, implementation, design and architecture of the application, as well as the tests performed and the results obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta Tesis aborda los problemas de eficiencia de las redes eléctrica desde el punto de vista del consumo. En particular, dicha eficiencia es mejorada mediante el suavizado de la curva de consumo agregado. Este objetivo de suavizado de consumo implica dos grandes mejoras en el uso de las redes eléctricas: i) a corto plazo, un mejor uso de la infraestructura existente y ii) a largo plazo, la reducción de la infraestructura necesaria para suplir las mismas necesidades energéticas. Además, esta Tesis se enfrenta a un nuevo paradigma energético, donde la presencia de generación distribuida está muy extendida en las redes eléctricas, en particular, la generación fotovoltaica (FV). Este tipo de fuente energética afecta al funcionamiento de la red, incrementando su variabilidad. Esto implica que altas tasas de penetración de electricidad de origen fotovoltaico es perjudicial para la estabilidad de la red eléctrica. Esta Tesis trata de suavizar la curva de consumo agregado considerando esta fuente energética. Por lo tanto, no sólo se mejora la eficiencia de la red eléctrica, sino que también puede ser aumentada la penetración de electricidad de origen fotovoltaico en la red. Esta propuesta conlleva grandes beneficios en los campos económicos, social y ambiental. Las acciones que influyen en el modo en que los consumidores hacen uso de la electricidad con el objetivo producir un ahorro energético o un aumento de eficiencia son llamadas Gestión de la Demanda Eléctrica (GDE). Esta Tesis propone dos algoritmos de GDE diferentes para cumplir con el objetivo de suavizado de la curva de consumo agregado. La diferencia entre ambos algoritmos de GDE reside en el marco en el cual estos tienen lugar: el marco local y el marco de red. Dependiendo de este marco de GDE, el objetivo energético y la forma en la que se alcanza este objetivo son diferentes. En el marco local, el algoritmo de GDE sólo usa información local. Este no tiene en cuenta a otros consumidores o a la curva de consumo agregado de la red eléctrica. Aunque esta afirmación pueda diferir de la definición general de GDE, esta vuelve a tomar sentido en instalaciones locales equipadas con Recursos Energéticos Distribuidos (REDs). En este caso, la GDE está enfocada en la maximización del uso de la energía local, reduciéndose la dependencia con la red. El algoritmo de GDE propuesto mejora significativamente el auto-consumo del generador FV local. Experimentos simulados y reales muestran que el auto-consumo es una importante estrategia de gestión energética, reduciendo el transporte de electricidad y alentando al usuario a controlar su comportamiento energético. Sin embargo, a pesar de todas las ventajas del aumento de auto-consumo, éstas no contribuyen al suavizado del consumo agregado. Se han estudiado los efectos de las instalaciones locales en la red eléctrica cuando el algoritmo de GDE está enfocado en el aumento del auto-consumo. Este enfoque puede tener efectos no deseados, incrementando la variabilidad en el consumo agregado en vez de reducirlo. Este efecto se produce porque el algoritmo de GDE sólo considera variables locales en el marco local. Los resultados sugieren que se requiere una coordinación entre las instalaciones. A través de esta coordinación, el consumo debe ser modificado teniendo en cuenta otros elementos de la red y buscando el suavizado del consumo agregado. En el marco de la red, el algoritmo de GDE tiene en cuenta tanto información local como de la red eléctrica. En esta Tesis se ha desarrollado un algoritmo autoorganizado para controlar el consumo de la red eléctrica de manera distribuida. El objetivo de este algoritmo es el suavizado del consumo agregado, como en las implementaciones clásicas de GDE. El enfoque distribuido significa que la GDE se realiza desde el lado de los consumidores sin seguir órdenes directas emitidas por una entidad central. Por lo tanto, esta Tesis propone una estructura de gestión paralela en lugar de una jerárquica como en las redes eléctricas clásicas. Esto implica que se requiere un mecanismo de coordinación entre instalaciones. Esta Tesis pretende minimizar la cantidad de información necesaria para esta coordinación. Para lograr este objetivo, se han utilizado dos técnicas de coordinación colectiva: osciladores acoplados e inteligencia de enjambre. La combinación de estas técnicas para llevar a cabo la coordinación de un sistema con las características de la red eléctrica es en sí mismo un enfoque novedoso. Por lo tanto, este objetivo de coordinación no es sólo una contribución en el campo de la gestión energética, sino también en el campo de los sistemas colectivos. Los resultados muestran que el algoritmo de GDE propuesto reduce la diferencia entre máximos y mínimos de la red eléctrica en proporción a la cantidad de energía controlada por el algoritmo. Por lo tanto, conforme mayor es la cantidad de energía controlada por el algoritmo, mayor es la mejora de eficiencia en la red eléctrica. Además de las ventajas resultantes del suavizado del consumo agregado, otras ventajas surgen de la solución distribuida seguida en esta Tesis. Estas ventajas se resumen en las siguientes características del algoritmo de GDE propuesto: • Robustez: en un sistema centralizado, un fallo o rotura del nodo central provoca un mal funcionamiento de todo el sistema. La gestión de una red desde un punto de vista distribuido implica que no existe un nodo de control central. Un fallo en cualquier instalación no afecta el funcionamiento global de la red. • Privacidad de datos: el uso de una topología distribuida causa de que no hay un nodo central con información sensible de todos los consumidores. Esta Tesis va más allá y el algoritmo propuesto de GDE no utiliza información específica acerca de los comportamientos de los consumidores, siendo la coordinación entre las instalaciones completamente anónimos. • Escalabilidad: el algoritmo propuesto de GDE opera con cualquier número de instalaciones. Esto implica que se permite la incorporación de nuevas instalaciones sin afectar a su funcionamiento. • Bajo coste: el algoritmo de GDE propuesto se adapta a las redes actuales sin requisitos topológicos. Además, todas las instalaciones calculan su propia gestión con un bajo requerimiento computacional. Por lo tanto, no se requiere un nodo central con un alto poder de cómputo. • Rápido despliegue: las características de escalabilidad y bajo coste de los algoritmos de GDE propuestos permiten una implementación rápida. No se requiere una planificación compleja para el despliegue de este sistema. ABSTRACT This Thesis addresses the efficiency problems of the electrical grids from the consumption point of view. In particular, such efficiency is improved by means of the aggregated consumption smoothing. This objective of consumption smoothing entails two major improvements in the use of electrical grids: i) in the short term, a better use of the existing infrastructure and ii) in long term, the reduction of the required infrastructure to supply the same energy needs. In addition, this Thesis faces a new energy paradigm, where the presence of distributed generation is widespread over the electrical grids, in particular, the Photovoltaic (PV) generation. This kind of energy source affects to the operation of the grid by increasing its variability. This implies that a high penetration rate of photovoltaic electricity is pernicious for the electrical grid stability. This Thesis seeks to smooth the aggregated consumption considering this energy source. Therefore, not only the efficiency of the electrical grid is improved, but also the penetration of photovoltaic electricity into the grid can be increased. This proposal brings great benefits in the economic, social and environmental fields. The actions that influence the way that consumers use electricity in order to achieve energy savings or higher efficiency in energy use are called Demand-Side Management (DSM). This Thesis proposes two different DSM algorithms to meet the aggregated consumption smoothing objective. The difference between both DSM algorithms lie in the framework in which they take place: the local framework and the grid framework. Depending on the DSM framework, the energy goal and the procedure to reach this goal are different. In the local framework, the DSM algorithm only uses local information. It does not take into account other consumers or the aggregated consumption of the electrical grid. Although this statement may differ from the general definition of DSM, it makes sense in local facilities equipped with Distributed Energy Resources (DERs). In this case, the DSM is focused on the maximization of the local energy use, reducing the grid dependence. The proposed DSM algorithm significantly improves the self-consumption of the local PV generator. Simulated and real experiments show that self-consumption serves as an important energy management strategy, reducing the electricity transport and encouraging the user to control his energy behavior. However, despite all the advantages of the self-consumption increase, they do not contribute to the smooth of the aggregated consumption. The effects of the local facilities on the electrical grid are studied when the DSM algorithm is focused on self-consumption maximization. This approach may have undesirable effects, increasing the variability in the aggregated consumption instead of reducing it. This effect occurs because the algorithm only considers local variables in the local framework. The results suggest that coordination between these facilities is required. Through this coordination, the consumption should be modified by taking into account other elements of the grid and seeking for an aggregated consumption smoothing. In the grid framework, the DSM algorithm takes into account both local and grid information. This Thesis develops a self-organized algorithm to manage the consumption of an electrical grid in a distributed way. The goal of this algorithm is the aggregated consumption smoothing, as the classical DSM implementations. The distributed approach means that the DSM is performed from the consumers side without following direct commands issued by a central entity. Therefore, this Thesis proposes a parallel management structure rather than a hierarchical one as in the classical electrical grids. This implies that a coordination mechanism between facilities is required. This Thesis seeks for minimizing the amount of information necessary for this coordination. To achieve this objective, two collective coordination techniques have been used: coupled oscillators and swarm intelligence. The combination of these techniques to perform the coordination of a system with the characteristics of the electric grid is itself a novel approach. Therefore, this coordination objective is not only a contribution in the energy management field, but in the collective systems too. Results show that the proposed DSM algorithm reduces the difference between the maximums and minimums of the electrical grid proportionally to the amount of energy controlled by the system. Thus, the greater the amount of energy controlled by the algorithm, the greater the improvement of the efficiency of the electrical grid. In addition to the advantages resulting from the smoothing of the aggregated consumption, other advantages arise from the distributed approach followed in this Thesis. These advantages are summarized in the following features of the proposed DSM algorithm: • Robustness: in a centralized system, a failure or breakage of the central node causes a malfunction of the whole system. The management of a grid from a distributed point of view implies that there is not a central control node. A failure in any facility does not affect the overall operation of the grid. • Data privacy: the use of a distributed topology causes that there is not a central node with sensitive information of all consumers. This Thesis goes a step further and the proposed DSM algorithm does not use specific information about the consumer behaviors, being the coordination between facilities completely anonymous. • Scalability: the proposed DSM algorithm operates with any number of facilities. This implies that it allows the incorporation of new facilities without affecting its operation. • Low cost: the proposed DSM algorithm adapts to the current grids without any topological requirements. In addition, every facility calculates its own management with low computational requirements. Thus, a central computational node with a high computational power is not required. • Quick deployment: the scalability and low cost features of the proposed DSM algorithms allow a quick deployment. A complex schedule of the deployment of this system is not required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El proyecto fin de carrera “Sistema Portátil de Medida de Dispositivos Sometidos a Ensayos en Campo” es un proyecto acometido para el desarrollo y evaluación de un sistema de medición portátil y confiable, que permita la realización de mediciones de curvas I-V en campo, en condiciones reales de funcionamiento. Dado que la finalidad de este proyecto fin de carrera es la obtención de un sistema para la realización de mediciones en campo, en la implementación del proyecto se tendrán como requisitos principales de diseño el tamaño, la fuente de alimentación, el peso del sistema, además de la fiabilidad y una relativa precisión en la realización de mediciones. Durante la realización de este proyecto y dados los requerimientos anteriores de portabilidad y fiabilidad, se ha buscado ofrecer una solución de compromiso diseñando un equipamiento que sea realizable, que cumpla con los objetivos anteriores con un coste que no sea elevado y con la característica de que disponga de una facilidad de manejo que permita a cualquier usuario la utilización del mismo. El sistema final diseñado está basado en el dispositivo de adquisición de datos MyDAQ de National Instruments que permite la realización de múltiples tipos de mediciones. En base a este dispositivo de adquisición de datos, se ha diseñado un sistema de medición con una arquitectura que se implementa a través de un ordenador portátil, con un software de medición instalado que recopila e interpreta los datos, y que alimenta y controla al dispositivo a través del puerto USB. El sistema también implementa una carga variable que permite la medición de la curva I-V en iluminación de células o mini-paneles fotovoltaicos. Este diseño permite que para la realización de las mediciones de las curvas I-V en iluminación en campo sólo se requiera conectar el dispositivo de adquisición a un PC portátil con batería y a la carga variable. Aunque este diseño es específico para la medición de células solares se ha implementado de forma que pueda extrapolarse fácilmente a otro tipo de medición de tensión y corriente. Para la comprobación de la precisión del sistema portátil de medidas, durante el proyecto se ha procedido a la comparación de los resultados obtenidos del sistema diseñado con un equipo de caracterización en laboratorio. Dicho sistema de alta exactitud permite cuantificar la degradación real de la célula y establecer una comparación de mediciones con el sistema portátil de medida, ofreciendo resultados satisfactorios en todas las mediciones realizadas y permitiendo concluir la evaluación del sistema portátil como apto para las mediciones de dispositivos en campo. El proceso de evaluación del equipamiento diseñado consistiría en la medida de la curva I-V en laboratorio de un dispositivo fotovoltaico con instrumentación de alta precisión y condiciones controladas de luz y temperatura de un dispositivo, célula o mini-panel. Tras la medida inicial las células se instalarían en campo y se realizaría una caracterización periódica de los dispositivos mediante el sistema portátil de medida, que permitiría evidenciar si en la curva I-V bajo iluminación existe degradación, y en qué zona de la curva. Al finalizar el ensayo o en periodos intermedios se desmontarían los dispositivos para volver a medir la curva I-V con exactitud en laboratorio. Por tanto el sistema portátil de medida, debe permitir evaluar la evolución de la curva I-V en condiciones ambientales similares a obtenidas en medidas anteriores, y a partir de la misma determinar el modo de degradación del dispositivo, no siendo necesaria una elevada precisión de medida para ofrecer resultados exactos de degradación, que sólo podrán medirse en el laboratorio. ABSTRACT. The final degree project "Portable Measurement System For Devices Under Field Tests" is a project undertaken for the development and evaluation of portable and reliable measurement equipment, which allows the realization of I-V curve measurements in field conditions actual operation. Since the purpose of this final project is to obtain a system for conducting field measurements in the implementation of the project will have as main design requirements for size, power supply, system weight, plus reliability and precision relative to the taking of measurements. During the development of this project and given the above requirements portability and reliability, has sought to offer a compromise designing equipment that is achievable, that meets the above objectives with a cost that is not high and the feature that available management facility that allows any user to use it. The final system is designed based on the acquisition device MyDAQ NI data that allows the execution of multiple types of measurements. Based on this data acquisition device, we have designed a measurement system with an architecture that is implemented via a laptop, with measurement software installed that collects and interprets data, and feeds and controls the device through the USB port. The system also implements a variable load which allows measurement of the I-V curve lighting photovoltaic cells. This design allows performing measurements of I-V curves in lighting field is only required to connect the device to purchase a laptop with a battery and variable load. Although this design is specific for the measurement of solar cells has been implemented so that it can easily be extrapolated to other types of measuring voltage and current. To test the accuracy of the portable measurement system during the project has been carried out to compare the results of the designed system, a team of laboratory characterization. This system of high accuracy to quantify the actual degradation of the cell and a comparison of measurements with portable measurement system, providing satisfactory results in all measurements and allowing complete portable system assessment as suitable for measurements of devices field. The evaluation process designed equipment would be far laboratory I-V curve of a photovoltaic device with high precision instrumentation controlled light and temperature of a device, panel or mini-cell conditions. After initial measurement cells settle in a periodic field and device characterization will be achieved through the portable measurement system, which would show whether the I-V curve under illumination degradation exists, and in which area of the curve. At the end of the trial or in interim periods devices to remeasure the I-V curve accurately in laboratory dismount. Therefore the portable measurement system should allow evaluating the evolution of the I-V curve similar to previous measurements obtained in ambient conditions, and from it determine the mode of degradation of the device, not a high measurement accuracy to be necessary to provide degradation accurate results, which can only be measured in the laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the framework of the ITER Control Breakdown Structure (CBS), Plant System Instrumentation & Control (I&C) defines the hardware and software required to control one or more plant systems [1]. For diagnostics, most of the complex Plant System I&C are to be delivered by ITER Domestic Agencies (DAs). As an example for the DAs, ITER Organization (IO) has developed several use cases for diagnostics Plant System I&C that fully comply with guidelines presented in the Plant Control Design Handbook (PCDH) [2]. One such use case is for neutron diagnostics, specifically the Fission Chamber (FC), which is responsible for delivering time-resolved measurements of neutron source strength and fusion power to aid in assessing the functional performance of ITER [3]. ITER will deploy four Fission Chamber units, each consisting of three individual FC detectors. Two of these detectors contain Uranium 235 for Neutron detection, while a third "dummy" detector will provide gamma and noise detection. The neutron flux from each MFC is measured by the three methods: . Counting Mode: measures the number of individual pulses and their location in the record. Pulse parameters (threshold and width) are user configurable. . Campbelling Mode (Mean Square Voltage): measures the RMS deviation in signal amplitude from its average value. .Current Mode: integrates the signal amplitude over the measurement period

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El desarrollo da las nuevas tecnologías permite a los ingenieros llevar al límite el funcionamiento de los circuitos integrados (Integrated Circuits, IC). Las nuevas generaciones de procesadores, DSPs o FPGAs son capaces de procesar la información a una alta velocidad, con un alto consumo de energía, o esperar en modo de baja potencia con el mínimo consumo posible. Esta gran variación en el consumo de potencia y el corto tiempo necesario para cambiar de un nivel al otro, afecta a las especificaciones del Módulo de Regulador de Tensión (Voltage Regulated Module, VRM) que alimenta al IC. Además, las características adicionales obligatorias, tales como adaptación del nivel de tensión (Adaptive Voltage Positioning, AVP) y escalado dinámico de la tensión (Dynamic Voltage Scaling, DVS), imponen requisitos opuestas en el diseño de la etapa de potencia del VRM. Para poder soportar las altas variaciones de los escalones de carga, el condensador de filtro de salida del VRM se ha de sobredimensionar, penalizando la densidad de energía y el rendimiento durante la operación de DVS. Por tanto, las actuales tendencias de investigación se centran en mejorar la respuesta dinámica del VRM, mientras se reduce el tamaño del condensador de salida. La reducción del condensador de salida lleva a menor coste y una prolongación de la vida del sistema ya que se podría evitar el uso de condensadores voluminosos, normalmente implementados con condensadores OSCON. Una ventaja adicional es que reduciendo el condensador de salida, el DVS se puede realizar más rápido y con menor estrés de la etapa de potencia, ya que la cantidad de carga necesaria para cambiar la tensión de salida es menor. El comportamiento dinámico del sistema con un control lineal (Control Modo Tensión, VMC, o Control Corriente de Pico, Peak Current Mode Control, PCMC,…) está limitado por la frecuencia de conmutación del convertidor y por el tamaño del filtro de salida. La reducción del condensador de salida se puede lograr incrementando la frecuencia de conmutación, así como incrementando el ancho de banda del sistema, y/o aplicando controles avanzados no-lineales. Usando esos controles, las variables del estado se saturan para conseguir el nuevo régimen permanente en un tiempo mínimo, así como el filtro de salida, más específicamente la pendiente de la corriente de la bobina, define la respuesta de la tensión de salida. Por tanto, reduciendo la inductancia de la bobina de salida, la corriente de bobina llega más rápido al nuevo régimen permanente, por lo que una menor cantidad de carga es tomada del condensador de salida durante el tránsito. El inconveniente de esa propuesta es que el rendimiento del sistema es penalizado debido al incremento de pérdidas de conmutación y las corrientes RMS. Para conseguir tanto la reducción del condensador de salida como el alto rendimiento del sistema, mientras se satisfacen las estrictas especificaciones dinámicas, un convertidor multifase es adoptado como estándar para aplicaciones VRM. Para asegurar el reparto de las corrientes entre fases, el convertidor multifase se suele implementar con control de modo de corriente. Para superar la limitación impuesta por el filtro de salida, la segunda posibilidad para reducir el condensador de salida es aplicar alguna modificación topológica (Topologic modifications) de la etapa básica de potencia para incrementar la pendiente de la corriente de bobina y así reducir la duración de tránsito. Como el transitorio se ha reducido, una menor cantidad de carga es tomada del condensador de salida bajo el mismo escalón de la corriente de salida, con lo cual, el condensador de salida se puede reducir para lograr la misma desviación de la tensión de salida. La tercera posibilidad para reducir el condensador de salida del convertidor es introducir un camino auxiliar de energía (additional energy path, AEP) para compensar el desequilibrio de la carga del condensador de salida reduciendo consecuentemente la duración del transitorio y la desviación de la tensión de salida. De esta manera, durante el régimen permanente, el sistema tiene un alto rendimiento debido a que el convertidor principal con bajo ancho de banda es diseñado para trabajar con una frecuencia de conmutación moderada para conseguir requisitos estáticos. Por otro lado, el comportamiento dinámico durante los transitorios es determinado por el AEP con un alto ancho de banda. El AEP puede ser implementado como un camino resistivo, como regulador lineal (Linear regulator, LR) o como un convertidor conmutado. Las dos primeras implementaciones proveen un mayor ancho de banda, acosta del incremento de pérdidas durante el transitorio. Por otro lado, la implementación del convertidor computado presenta menor ancho de banda, limitado por la frecuencia de conmutación, aunque produce menores pérdidas comparado con las dos anteriores implementaciones. Dependiendo de la aplicación, la implementación y la estrategia de control del sistema, hay una variedad de soluciones propuestas en el Estado del Arte (State-of-the-Art, SoA), teniendo diferentes propiedades donde una solución ofrece más ventajas que las otras, pero también unas desventajas. En general, un sistema con AEP ideal debería tener las siguientes propiedades: 1. El impacto del AEP a las pérdidas del sistema debería ser mínimo. A lo largo de la operación, el AEP genera pérdidas adicionales, con lo cual, en el caso ideal, el AEP debería trabajar por un pequeño intervalo de tiempo, solo durante los tránsitos; la otra opción es tener el AEP constantemente activo pero, por la compensación del rizado de la corriente de bobina, se generan pérdidas innecesarias. 2. El AEP debería ser activado inmediatamente para minimizar la desviación de la tensión de salida. Para conseguir una activación casi instantánea, el sistema puede ser informado por la carga antes del escalón o el sistema puede observar la corriente del condensador de salida, debido a que es la primera variable del estado que actúa a la perturbación de la corriente de salida. De esa manera, el AEP es activado con casi cero error de la tensión de salida, logrando una menor desviación de la tensión de salida. 3. El AEP debería ser desactivado una vez que el nuevo régimen permanente es detectado para evitar los transitorios adicionales de establecimiento. La mayoría de las soluciones de SoA estiman la duración del transitorio, que puede provocar un transitorio adicional si la estimación no se ha hecho correctamente (por ejemplo, si la corriente de bobina del convertidor principal tiene un nivel superior o inferior al necesitado, el regulador lento del convertidor principal tiene que compensar esa diferencia una vez que el AEP es desactivado). Otras soluciones de SoA observan las variables de estado, asegurando que el sistema llegue al nuevo régimen permanente, o pueden ser informadas por la carga. 4. Durante el transitorio, como mínimo un subsistema, o bien el convertidor principal o el AEP, debería operar en el lazo cerrado. Implementando un sistema en el lazo cerrado, preferiblemente el subsistema AEP por su ancho de banda elevado, se incrementa la robustez del sistema a los parásitos. Además, el AEP puede operar con cualquier tipo de corriente de carga. Las soluciones que funcionan en el lazo abierto suelen preformar el control de balance de carga con mínimo tiempo, así reducen la duración del transitorio y tienen un impacto menor a las pérdidas del sistema. Por otro lado, esas soluciones demuestran una alta sensibilidad a las tolerancias y parásitos de los componentes. 5. El AEP debería inyectar la corriente a la salida en una manera controlada, así se reduce el riesgo de unas corrientes elevadas y potencialmente peligrosas y se incrementa la robustez del sistema bajo las perturbaciones de la tensión de entrada. Ese problema suele ser relacionado con los sistemas donde el AEP es implementado como un convertidor auxiliar. El convertidor auxiliar es diseñado para una potencia baja, con lo cual, los dispositivos elegidos son de baja corriente/potencia. Si la corriente no es controlada, bajo un pico de tensión de entrada provocada por otro parte del sistema (por ejemplo, otro convertidor conectado al mismo bus), se puede llegar a un pico en la corriente auxiliar que puede causar la perturbación de tensión de salida e incluso el fallo de los dispositivos del convertidor auxiliar. Sin embargo, cuando la corriente es controlada, usando control del pico de corriente o control con histéresis, la corriente auxiliar tiene el control con prealimentación (feed-forward) de tensión de entrada y la corriente es definida y limitada. Por otro lado, si la solución utiliza el control de balance de carga, el sistema puede actuar de forma deficiente si la tensión de entrada tiene un valor diferente del nominal, provocando que el AEP inyecta/toma más/menos carga que necesitada. 6. Escalabilidad del sistema a convertidores multifase. Como ya ha sido comentado anteriormente, para las aplicaciones VRM por la corriente de carga elevada, el convertidor principal suele ser implementado como multifase para distribuir las perdidas entre las fases y bajar el estrés térmico de los dispositivos. Para asegurar el reparto de las corrientes, normalmente un control de modo corriente es usado. Las soluciones de SoA que usan VMC son limitadas a la implementación con solo una fase. Esta tesis propone un nuevo método de control del flujo de energía por el AEP y el convertidor principal. El concepto propuesto se basa en la inyección controlada de la corriente auxiliar al nodo de salida donde la amplitud de la corriente es n-1 veces mayor que la corriente del condensador de salida con las direcciones apropiadas. De esta manera, el AEP genera un condensador virtual cuya capacidad es n veces mayor que el condensador físico y reduce la impedancia de salida. Como el concepto propuesto reduce la impedancia de salida usando el AEP, el concepto es llamado Output Impedance Correction Circuit (OICC) concept. El concepto se desarrolla para un convertidor tipo reductor síncrono multifase con control modo de corriente CMC (incluyendo e implementación con una fase) y puede operar con la tensión de salida constante o con AVP. Además, el concepto es extendido a un convertidor de una fase con control modo de tensión VMC. Durante la operación, el control de tensión de salida de convertidor principal y control de corriente del subsistema OICC están siempre cerrados, incrementando la robustez a las tolerancias de componentes y a los parásitos del cirquito y permitiendo que el sistema se pueda enfrentar a cualquier tipo de la corriente de carga. Según el método de control propuesto, el sistema se puede encontrar en dos estados: durante el régimen permanente, el sistema se encuentra en el estado Idle y el subsistema OICC esta desactivado. Por otro lado, durante el transitorio, el sistema se encuentra en estado Activo y el subsistema OICC está activado para reducir la impedancia de salida. El cambio entre los estados se hace de forma autónoma: el sistema entra en el estado Activo observando la corriente de condensador de salida y vuelve al estado Idle cunado el nuevo régimen permanente es detectado, observando las variables del estado. La validación del concepto OICC es hecha aplicándolo a un convertidor tipo reductor síncrono con dos fases y de 30W cuyo condensador de salida tiene capacidad de 140μF, mientras el factor de multiplicación n es 15, generando en el estado Activo el condensador virtual de 2.1mF. El subsistema OICC es implementado como un convertidor tipo reductor síncrono con PCMC. Comparando el funcionamiento del convertidor con y sin el OICC, los resultados demuestran que se ha logrado una reducción de la desviación de tensión de salida con factor 12, tanto con funcionamiento básico como con funcionamiento AVP. Además, los resultados son comparados con un prototipo de referencia que tiene la misma etapa de potencia y un condensador de salida físico de 2.1mF. Los resultados demuestran que los dos sistemas tienen el mismo comportamiento dinámico. Más aun, se ha cuantificado el impacto en las pérdidas del sistema operando bajo una corriente de carga pulsante y bajo DVS. Se demuestra que el sistema con OICC mejora el rendimiento del sistema, considerando las pérdidas cuando el sistema trabaja con la carga pulsante y con DVS. Por lo último, el condensador de salida de sistema con OICC es mucho más pequeño que el condensador de salida del convertidor de referencia, con lo cual, por usar el concepto OICC, la densidad de energía se incrementa. En resumen, las contribuciones principales de la tesis son: • El concepto propuesto de Output Impedance Correction Circuit (OICC), • El control a nivel de sistema basado en el método usado para cambiar los estados de operación, • La implementación del subsistema OICC en lazo cerrado conjunto con la implementación del convertidor principal, • La cuantificación de las perdidas dinámicas bajo la carga pulsante y bajo la operación DVS, y • La robustez del sistema bajo la variación del condensador de salida y bajo los escalones de carga consecutiva. ABSTRACT Development of new technologies allows engineers to push the performance of the integrated circuits to its limits. New generations of processors, DSPs or FPGAs are able to process information with high speed and high consumption or to wait in low power mode with minimum possible consumption. This huge variation in power consumption and the short time needed to change from one level to another, affect the specifications of the Voltage Regulated Module (VRM) that supplies the IC. Furthermore, additional mandatory features, such as Adaptive Voltage Positioning (AVP) and Dynamic Voltage Scaling (DVS), impose opposite trends on the design of the VRM power stage. In order to cope with high load-step amplitudes, the output capacitor of the VRM power stage output filter is drastically oversized, penalizing power density and the efficiency during the DVS operation. Therefore, the ongoing research trend is directed to improve the dynamic response of the VRM while reducing the size of the output capacitor. The output capacitor reduction leads to a smaller cost and longer life-time of the system since the big bulk capacitors, usually implemented with OSCON capacitors, may not be needed to achieve the desired dynamic behavior. An additional advantage is that, by reducing the output capacitance, dynamic voltage scaling (DVS) can be performed faster and with smaller stress on the power stage, since the needed amount of charge to change the output voltage is smaller. The dynamic behavior of the system with a linear control (Voltage mode control, VMC, Peak Current Mode Control, PCMC,…) is limited by the converter switching frequency and filter size. The reduction of the output capacitor can be achieved by increasing the switching frequency of the converter, thus increasing the bandwidth of the system, and/or by applying advanced non-linear controls. Applying nonlinear control, the system variables get saturated in order to reach the new steady-state in a minimum time, thus the output filter, more specifically the output inductor current slew-rate, determines the output voltage response. Therefore, by reducing the output inductor value, the inductor current reaches faster the new steady state, so a smaller amount of charge is taken from the output capacitor during the transient. The drawback of this approach is that the system efficiency is penalized due to increased switching losses and RMS currents. In order to achieve both the output capacitor reduction and high system efficiency, while satisfying strict dynamic specifications, a Multiphase converter system is adopted as a standard for VRM applications. In order to ensure the current sharing among the phases, the multiphase converter is usually implemented with current mode control. In order to overcome the limitation imposed by the output filter, the second possibility to reduce the output capacitor is to apply Topologic modifications of the basic power stage topology in order to increase the slew-rate of the inductor current and, therefore, reduce the transient duration. Since the transient is reduced, smaller amount of charge is taken from the output capacitor under the same load current, thus, the output capacitor can be reduced to achieve the same output voltage deviation. The third possibility to reduce the output capacitor of the converter is to introduce an additional energy path (AEP) to compensate the charge unbalance of the output capacitor, consequently reducing the transient time and output voltage deviation. Doing so, during the steady-state operation the system has high efficiency because the main low-bandwidth converter is designed to operate at moderate switching frequency, to meet the static requirements, whereas the dynamic behavior during the transients is determined by the high-bandwidth auxiliary energy path. The auxiliary energy path can be implemented as a resistive path, as a Linear regulator, LR, or as a switching converter. The first two implementations provide higher bandwidth, at the expense of increasing losses during the transient. On the other hand, the switching converter implementation presents lower bandwidth, limited by the auxiliary converter switching frequency, though it produces smaller losses compared to the two previous implementations. Depending on the application, the implementation and the control strategy of the system, there is a variety of proposed solutions in the State-of-the-Art (SoA), having different features where one solution offers some advantages over the others, but also some disadvantages. In general, an ideal additional energy path system should have the following features: 1. The impact on the system losses should be minimal. During its operation, the AEP generates additional losses, thus ideally, the AEP should operate for a short period of time, only when the transient is occurring; the other option is to have the AEP constantly on, but due to the inductor current ripple compensation at the output, unnecessary losses are generated. 2. The AEP should be activated nearly instantaneously to prevent bigger output voltage deviation. To achieve near instantaneous activation, the converter system can be informed by the load prior to the load-step or the system can observe the output capacitor current, which is the first system state variable that reacts on the load current perturbation. In this manner, the AEP is turned on with near zero output voltage error, providing smaller output voltage deviation. 3. The AEP should be deactivated once the new steady state is reached to avoid additional settling transients. Most of the SoA solutions estimate duration of the transient which may cause additional transient if the estimation is not performed correctly (e.g. if the main converter inductor current has higher or lower value than needed, the slow regulator of the main converter needs to compensate the difference after the AEP is deactivated). Other SoA solutions are observing state variables, ensuring that the system reaches the new steady state or they are informed by the load. 4. During the transient, at least one subsystem, either the main converter or the AEP, should be in closed-loop. Implementing a closed loop system, preferably the AEP subsystem, due its higher bandwidth, increases the robustness under system tolerances and circuit parasitic. In addition, the AEP can operate with any type of load. The solutions that operate in open loop usually perform minimum time charge balance control, thus reducing the transient length and minimizing the impact on the losses, however they are very sensitive to tolerances and parasitics. 5. The AEP should inject current at the output in a controlled manner, thus reducing the risk of high and potentially damaging currents and increasing robustness on the input voltage deviation. This issue is mainly related to the systems where AEP is implemented as auxiliary converter. The auxiliary converter is designed for small power and, as such, the MOSFETs are rated for small power/currents. If the current is not controlled, due to the some unpredicted spike in input voltage caused by some other part of the system (e.g. different converter), it may lead to a current spike in auxiliary current which will cause the perturbation of the output voltage and even failure of the switching components of auxiliary converter. In the case when the current is controlled, using peak CMC or Hysteretic Window CMC, the auxiliary converter has inherent feed-forwarding of the input voltage in current control and the current is defined and limited. Furthermore, if the solution employs charge balance control, the system may perform poorly if the input voltage has different value than the nominal, causing that AEP injects/extracts more/less charge than needed. 6. Scalability of the system to multiphase converters. As commented previously, in VRM applications, due to the high load currents, the main converters are implemented as multiphase to redistribute losses among the modules, lowering temperature stress of the components. To ensure the current sharing, usually a Current Mode Control (CMC) is employed. The SoA solutions that are implemented with VMC are limited to a single stage implementation. This thesis proposes a novel control method of the energy flow through the AEP and the main converter system. The proposed concept relays on a controlled injection of the auxiliary current at the output node where the instantaneous current value is n-1 times bigger than the output capacitor current with appropriate directions. Doing so, the AEP creates an equivalent n times bigger virtual capacitor at the output, thus reducing the output impedance. Due to the fact that the proposed concept reduces the output impedance using the AEP, it has been named the Output Impedance Correction Circuit (OICC) concept. The concept is developed for a multiphase CMC synchronous buck converter (including a single phase implementation), operating with a constant output voltage and with AVP feature. Further, it is extended to a single phase VMC synchronous buck converter. During the operation, the main converter voltage loop and the OICC subsystem capacitor current loop is constantly closed, increasing the robustness under system tolerances and circuit parasitic and allowing the system to operate with any load-current shape or pattern. According to the proposed control method, the system operates in two states: during the steady-state the system is in the Idle state and the OICC subsystem is deactivated, while during the load-step transient the system is in the Active state and the OICC subsystem is activated in order to reduce the output impedance. The state changes are performed autonomously: the system enters in the Active state by observing the output capacitor current and it returns back to the Idle state when the steady-state operation is detected by observing the state variables. The validation of the OICC concept has been done by applying it to a 30W two phase synchronous buck converter with 140μF output capacitor and with the multiplication factor n equal to 15, generating during the Active state equivalent output capacitor of 2.1mF. The OICC subsystem is implemented as single phase PCMC synchronous buck converter. Comparing the converter operation with and without the OICC the results demonstrate that the 12 times reduction of the output voltage deviation is achieved, for both basic operation and for the AVP operation. Furthermore, the results have been compared to a reference prototype which has the same power stage and a fiscal output capacitor of 2.1mF. The results show that the two systems have the same dynamic behavior. Moreover, an impact on the system losses under the pulsating load and DVS operation has been quantified and it has been demonstrated that the OICC system has improved the system efficiency, considering the losses when the system operates with the pulsating load and the DVS operation. Lastly, the output capacitor of the OICC system is much smaller than the reference design output capacitor, therefore, by applying the OICC concept the power density can be increased. In summary, the main contributions of the thesis are: • The proposed Output Impedance Correction Circuit (OICC) concept, • The system level control based on the used approach to change the states of operation, • The OICC subsystem closed-loop implementation, together with the main converter implementation, • The dynamic losses under the pulsating load and the DVS operation quantification, and • The system robustness on the capacitor impedance variation and consecutive load-steps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El nitrógeno (N) y el fósforo (P) son nutrientes esenciales en la producción de cultivos. El desarrollo de los fertilizantes de síntesis durante el siglo XX permitió una intensificación de la agricultura y un aumento de las producciones pero a su vez el gran input de nutrientes ha resultado en algunos casos en sistemas poco eficientes incrementando las pérdidas de estos nutrientes al medio ambiente. En el caso del P, este problema se agrava debido a la escasez de reservas de roca fosfórica necesaria para la fabricación de fertilizantes fosfatados. La utilización de residuos orgánicos en agricultura como fuente de N y P es una buena opción de manejo que permite valorizar la gran cantidad de residuos que se generan. Sin embargo, es importante conocer los procesos que se producen en el suelo tras la aplicación de los mismos, ya que influyen en la disponibilidad de nutrientes que pueden ser utilizados por el cultivo así como en las pérdidas de nutrientes de los agrosistemas que pueden ocasionar problemas de contaminación. Aunque la dinámica del N en el suelo ha sido más estudiada que la del P, los problemas importantes de contaminación por nitratos en zonas vulnerables hacen necesaria la evaluación de aquellas prácticas de manejo que pudieran agravar esta situación, y en el caso de los residuos orgánicos, la evaluación de la respuesta agronómica y medioambiental de la aplicación de materiales con un alto contenido en N (como los residuos procedentes de la industria vinícola y alcoholera). En cuanto al P, debido a la mayor complejidad de su ciclo y de las reacciones que ocurren en el suelo, hay un mayor desconocimiento de los factores que influyen en su dinámica en los sistemas suelo-planta, lo que supone nuevas oportunidades de estudio en la evaluación del uso agrícola de los residuos orgánicos. Teniendo en cuenta los conocimientos previos sobre cada nutriente así como las necesidades específicas en el estudio de los mismos, en esta Tesis se han evaluado: (1) el efecto de la aplicación de residuos procedentes de la industria vinícola y alcoholera en la dinámica del N desde el punto de vista agronómico y medioambiental en una zona vulnerable a la contaminación por nitratos; y (2) los factores que influyen en la disponibilidad de P en el suelo tras la aplicación de residuos orgánicos. Para ello se han llevado a cabo incubaciones de laboratorio así como ensayos de campo que permitieran evaluar la dinámica de estos nutrientes en condiciones reales. Las incubaciones de suelo en condiciones controladas de humedad y temperatura para determinar el N mineralizado se utilizan habitualmente para estimar la disponibilidad de N para el cultivo así como el riesgo medioambiental. Por ello se llevó a cabo una incubación en laboratorio para conocer la velocidad de mineralización de N de un compost obtenido a partir de residuos de la industria vinícola y alcoholera, ampliamente distribuida en Castilla-La Mancha, región con problemas importantes de contaminación de acuíferos por nitratos. Se probaron tres dosis crecientes de compost correspondientes a 230, 460 y 690 kg de N total por hectárea que se mezclaron con un suelo franco arcillo arenoso de la zona. La evolución del N mineral en el suelo a lo largo del tiempo se ajustó a un modelo de regresión no lineal, obteniendo valores bajos de N potencialmente mineralizable y bajas contantes de mineralización, lo que indica que se trata de un material resistente a la mineralización y con una lenta liberación de N en el suelo, mineralizándose tan solo 1.61, 1.33 y 1.21% del N total aplicado con cada dosis creciente de compost (para un periodo de seis meses). Por otra parte, la mineralización de N tras la aplicación de este material también se evaluó en condiciones de campo, mediante la elaboración de un balance de N durante dos ciclos de cultivo (2011 y 2012) de melón bajo riego por goteo, cultivo y manejo agrícola muy característicos de la zona de estudio. Las constantes de mineralización obtenidas en el laboratorio se ajustaron a las temperaturas reales en campo para predecir el N mineralizado en campo durante el ciclo de cultivo del melón, sin embargo este modelo generalmente sobreestimaba el N mineralizado observado en campo, por la influencia de otros factores no tenidos en cuenta para obtener esta predicción, como el N acumulado en el suelo, el efecto de la planta o las fluctuaciones de temperatura y humedad. Tanto el ajuste de los datos del laboratorio al modelo de mineralización como las predicciones del mismo fueron mejores cuando se consideraba el efecto de la mezcla suelo-compost que cuando se aislaba el N mineralizado del compost, mostrando la importancia del efecto del suelo en la mineralización del N procedente de residuos orgánicos. Dado que esta zona de estudio ha sido declarada vulnerable a la contaminación por nitratos y cuenta con diferentes unidades hidrológicas protegidas, en el mismo ensayo de campo con melón bajo riego por goteo se evaluó el riesgo de contaminación por nitratos tras la aplicación de diferentes dosis de compost bajo dos regímenes de riego, riego ajustado a las necesidades del cultivo (90 ó 100% de la evapotranspiración del cultivo (ETc)) o riego excedentario (120% ETc). A lo largo del ciclo de cultivo se estimó semanalmente el drenaje mediante la realización de un balance hídrico, así como se tomaron muestras de la solución de suelo y se determinó su concentración de nitratos. Para evaluar el riesgo de contaminación de las aguas subterráneas asociado con estas prácticas, se utilizaron algunos índices medioambientales para determinar la variación en la calidad del agua potable (Índice de Impacto (II)) y en la concentración de nitratos del acuífero (Índice de Impacto Ambiental (EII)). Para combinar parámetros medioambientales con parámetros de producción, se calculó la eficiencia de manejo. Se observó que la aplicación de compost bajo un régimen de riego ajustado no aumentaba el riesgo de contaminación de las aguas subterráneas incluso con la aplicación de la dosis más alta. Sin embargo, la aplicación de grandes cantidades de compost combinada con un riego excedentario supuso un incremento en el N lixiviado a lo largo del ciclo de cultivo, mientras que no se obtuvieron mayores producciones con respecto al riego ajustado. La aplicación de residuos de la industria vinícola y alcoholera como fuente de P fue evaluada en suelos calizos caracterizados por una alta capacidad de retención de P, lo cual en algunos casos limita la disponibilidad de este nutriente. Para ello se llevó a cabo otro ensayo de incubación con dos suelos de diferente textura, con diferente contenido de carbonato cálcico, hierro y con dos niveles de P disponible; a los que se aplicaron diferentes materiales procedentes de estas industrias (con y sin compostaje previo) aportando diferentes cantidades de P. A lo largo del tiempo se analizó el P disponible del suelo (P Olsen) así como el pH y el carbono orgánico disuelto. Al final de la incubación, con el fin de estudiar los cambios producidos por los diferentes residuos en el estado del P del suelo se llevó a cabo un fraccionamiento del P inorgánico del suelo, el cual se separó en P soluble y débilmente enlazado (NaOH-NaCl-P), P soluble en reductores u ocluido en los óxidos de Fe (CBD-P) y P poco soluble precipitado como Ca-P (HCl-P); y se determinó la capacidad de retención de P así como el grado de saturación de este elemento en el suelo. En este ensayo se observó que, dada la naturaleza caliza de los suelos, la influencia de la cantidad de P aplicado con los residuos en el P disponible sólo se producía al comienzo del periodo de incubación, mientras que al final del ensayo el incremento en el P disponible del suelo se igualaba independientemente del P aplicado con cada residuo, aumentando el P retenido en la fracción menos soluble con el aumento del P aplicado. Por el contrario, la aplicación de materiales orgánicos menos estabilizados y con un menor contenido en P, produjo un aumento en las formas de P más lábiles debido a una disolución del P retenido en la fracción menos lábil, lo cual demostró la influencia de la materia orgánica en los procesos que controlan el P disponible en el suelo. La aplicación de residuos aumentó el grado de saturación de P de los suelos, sin embargo los valores obtenidos no superaron los límites establecidos que indican un riesgo de contaminación de las aguas. La influencia de la aplicación de residuos orgánicos en las formas de P inorgánico y orgánico del suelo se estudió además en un suelo ácido de textura areno francosa tras la aplicación en campo a largo plazo de estiércol vacuno y de compost obtenido a partir de biorresiduos, así como la aplicación combinada de compost y un fertilizante mineral (superfosfato tripe), en una rotación de cultivos. En muestras de suelo recogidas 14 años después del establecimiento del experimento en campo, se determinó el P soluble y disponible, la capacidad de adsorción de P, el grado de saturación de P así como diferentes actividades enzimáticas (actividad deshidrogenasa, fosfatasa ácida y fosfatasa alcalina). Las diferentes formas de P orgánico en el suelo se estudiaron mediante una técnica de adición de enzimas con diferentes substratos específicos a extractos de suelo de NaOH-EDTA, midiendo el P hidrolizado durante un periodo de incubación por colorimetría. Las enzimas utilizadas fueron la fosfatasa ácida, la nucleasa y la fitasa las cuales permitieron identificar monoésteres hidrolizables (monoester-like P), diésteres (DNA-like P) e inositol hexaquifosfato (Ins6P-like P). La aplicación a largo plazo de residuos orgánicos aumentó el P disponible del suelo proporcionalmente al P aplicado con cada tipo de fertilización, suponiendo un mayor riesgo de pérdidas de P dado el alto grado de saturación de este suelo. La aplicación de residuos orgánicos aumentó el P orgánico del suelo resistente a la hidrólisis enzimática, sin embargo no influyó en las diferentes formas de P hidrolizable por las enzimas en comparación con las observadas en el suelo sin enmendar. Además, las diferentes formas de P orgánico aplicadas con los residuos orgánicos no se correspondieron con las analizadas en el suelo lo cual demostró que éstas son el resultado de diferentes procesos en el suelo mediados por las plantas, los microorganismos u otros procesos abióticos. En este estudio se encontró una correlación entre el Ins6P-like P y la actividad microbiana (actividad deshidrogenasa) del suelo, lo cual refuerza esta afirmación. Por último, la aplicación de residuos orgánicos como fuente de N y P en la agricultura se evaluó agronómicamente en un escenario real. Se estableció un experimento de campo para evaluar el compost procedente de residuos de bodegas y alcoholeras en el mismo cultivo de melón utilizado en el estudio de la mineralización y lixiviación de N. En este experimento se estudió la aplicación de tres dosis de compost: 1, 2 y 3 kg de compost por metro lineal de plantación correspondientes a 7, 13 y 20 t de compost por hectárea respectivamente; y se estudió el efecto sobre el crecimiento de las plantas, la acumulación de N y P en la planta, así como la producción y calidad del cultivo. La aplicación del compost produjo un ligero incremento en la biomasa vegetal acompañado por una mejora significativa de la producción con respecto a las parcelas no enmendadas, obteniéndose la máxima producción con la aplicación de 2 kg de compost por metro lineal. Aunque los efectos potenciales del N y P fueron parcialmente enmascarados por otras entradas de estos nutrientes en el sistema (alta concentración de nitratos en el agua de riego y ácido fosfórico suministrado por fertirrigación), se observó una mayor acumulación de P uno de los años de estudio que resultó en un aumento en el número de frutos en las parcelas enmendadas. Además, la mayor acumulación de N y P disponible en el suelo al final del ciclo de cultivo indicó el potencial uso de estos materiales como fuente de estos nutrientes. ABSTRACT Nitrogen (N) and phosphorus (P) are essential nutrients in crop production. The development of synthetic fertilizers during the 20th century allowed an intensification of the agriculture increasing crop yields but in turn the great input of nutrients has resulted in some cases in inefficient systems with higher losses to the environment. Regarding P, the scarcity of phosphate rock reserves necessary for the production of phosphate fertilizers aggravates this problem. The use of organic wastes in agriculture as a source of N and P is a good option of management that allows to value the large amount of wastes generated. However, it is important to understand the processes occurring in the soil after application of these materials, as they affect the availability of nutrients that can be used by the crop and the nutrient losses from agricultural systems that can cause problems of contamination. Although soil N dynamic has been more studied than P, the important concern of nitrate pollution in Nitrate Vulnerable Zones requires the evaluation of those management practices that could aggravate this situation, and in the case of organic wastes, the evaluation of the agronomic and environmental response after application of materials with a high N content (such as wastes from winery and distillery industries). On the other hand, due to the complexity of soil P cycle and the reactions that occur in soil, there is less knowledge about the factors that can influence its dynamics in the soil-plant system, which means new opportunities of study regarding the evaluation of the agricultural use of organic wastes. Taking into account the previous knowledge of each nutrient and the specific needs of study, in this Thesis we have evaluated: (1) the effect of the application of wastes from the winery and distillery industries on N dynamics from the agronomic and environmental viewpoint in a vulnerable zone; and (2) the factors that influence P availability in soils after the application of organic wastes. With this purposes, incubations were carried out in laboratory conditions as well as field trials that allow to assess the dynamic of these nutrients in real conditions. Soil incubations under controlled moisture and temperature conditions to determine N mineralization are commonly used to estimate N availability for crops together with the environmental risk. Therefore, a laboratory incubation was conducted in order to determine the N mineralization rate of a compost made from wastes generated in the winery and distillery industries, widely distributed in Castilla-La Mancha, a region with significant problems of aquifers contamination by nitrates. Three increasing doses of compost corresponding to 230, 460 and 690 kg of total N per hectare were mixed with a sandy clay loam soil collected in this area. The evolution of mineral N in soil over time was adjusted to a nonlinear regression model, obtaining low values of potentially mineralizable N and low constants of mineralization, indicating that it is a material resistant to mineralization with a slow release of N, with only 1.61, 1.33 and 1.21% of total N applied being mineralized with each increasing dose of compost (for a period of six months). Furthermore, N mineralization after the application of this material was also evaluated in field conditions by carrying out a N balance during two growing seasons (2011 and 2012) of a melon crop under drip irrigation, a crop and management very characteristic of the area of study. The mineralization constants obtained in the laboratory were adjusted to the actual temperatures observed in the field to predict N mineralized during each growing season, however, this model generally overestimated the N mineralization observed in the field, because of the influence of other factors not taken into account for this prediction, as N accumulated in soil, the plant effect or the fluctuations of temperature and moisture. The fitting of the laboratory data to the model as well as the predictions of N mineralized in the field were better when considering N mineralized from the soil-compost mixture rather than when N mineralized from compost was isolated, underlining the important role of the soil on N mineralization from organic wastes. Since the area of study was declared vulnerable to nitrate pollution and is situated between different protected hydrological units, the risk of nitrate pollution after application of different doses compost was evaluated in the same field trial with melon under two irrigation regimes, irrigation adjusted to the crop needs (90 or 100% of the crop evapotranspiration (ETc)) or excedentary irrigation (120% ETc). Drainage was estimated weekly throughout the growing season by conducting a water balance, samples of the soil solution were taken and the concentration of nitrates was determined. To assess the risk of groundwater contamination associated with these practices, some environmental indices were used to determine the variation in the quality of drinking water (Impact Index (II)) and the nitrates concentration in the groundwater (Environmental Impact Index (EII)). To combine environmental parameters together with yield parameters, the Management Efficiency was calculated. It was observed that the application of compost under irrigation adjusted to the plant needs did not represent a higher risk of groundwater contamination even with the application of the highest doses. However, the application of large amounts of compost combined with an irrigation surplus represented an increase of N leaching during the growing season compared with the unamended plots, while no additional yield with respect to the adjusted irrigation strategy is obtained. The application of wastes derived from the winery and distillery industry as source of P was evaluated in calcareous soils characterized by a high P retention capacity, which in some cases limits the availability of this nutrient. Another incubation experiment was carried out using two soils with different texture, different calcium carbonate and iron contents and two levels of available P; to which different materials from these industries (with and without composting) were applied providing different amounts of P. Soil available P (Olsen P), pH and dissolved organic carbon were analyzed along time. At the end of the incubation, in order to study the changes in soil P status caused by the different residues, a fractionation of soil inorganic P was carried out, which was separated into soluble and weakly bound P (NaOH-NaCl- P), reductant soluble P or occluded in Fe oxides (CBD-P) and P precipitated as poorly soluble Ca-P (HCl-P); and the P retention capacity and degree of P saturation were determined as well. Given the calcareous nature of the soils, the influence of the amount of P applied with the organic wastes in soil available P only occurred at the beginning of the incubation period, while at the end of the trial the increase in soil available P equalled independently of the amount of P applied with each residue, increasing the P retained in the least soluble fraction when increasing P applied. Conversely, the application of less stabilized materials with a lower content of P resulted in an increase in the most labile P forms due to dissolution of P retained in the less labile fraction, demonstrating the influence of organic matter addition on soil P processes that control P availability in soil. As expected, the application of organic wastes increased the degree of P saturation in the soils, however the values obtained did not exceed the limits considered to pose a risk of water pollution. The influence of the application of organic wastes on inorganic and organic soil P forms was also studied in an acid loamy sand soil after long-term field application of cattle manure and biowaste compost and the combined application of compost and mineral fertilizer (triple superphosphate) in a crop rotation. Soil samples were collected 14 years after the establishment of the field experiment, and analyzed for soluble and available P, P sorption capacity, degree of P saturation and enzymatic activities (dehydrogenase, acid phosphatase and alkaline phosphatase). The different forms of organic P in soil were determined by using an enzyme addition technique, based on adding enzymes with different substrate specificities to NaOH-EDTA soil extracts, measuring the hydrolyzed P colorimetrically after an incubation period. The enzymes used were acid phosphatase, nuclease and phytase which allowed to identify hydrolyzable monoesters (monoester-like P) diesters (DNA-like P) and inositol hexakisphosphate (Ins6P-like P). The long-term application of organic wastes increased soil available P proportionally to the P applied with each type of fertilizer, assuming a higher risk of P losses given the high degree of P saturation of this soil. The application of organic wastes increased soil organic P resistant to enzymatic hydrolysis, but no influence was observed regarding the different forms of enzyme hydrolyzable organic P compared to those observed in the non-amended soil. Furthermore, the different forms of organic P applied with the organic wastes did not correspond to those analyzed in the soil which showed that these forms in soil are a result of multifaceted P turnover processes in soil affected by plants, microorganisms and abiotic factors. In this study, a correlation between Ins6P-like P and the microbial activity (dehydrogenase activity) of soil was found, which reinforces this claim. Finally, the application of organic wastes as a source of N and P in agriculture was evaluated agronomically in a real field scenario. A field experiment was established to evaluate the application of compost made from wine-distillery wastes in the same melon crop used in the experiments of N mineralization and leaching. In this experiment the application of three doses of compost were studied: 1 , 2 and 3 kg of compost per linear meter of plantation corresponding to 7, 13 and 20 tonnes of compost per hectare respectively; and the effect on plant growth, N and P accumulation in the plant as well as crop yield and quality was studied. The application of compost produced a slight increase in plant biomass accompanied by a significant improvement in crop yield with respect to the unamended plots, obtaining the maximum yield with the application of 2 kg of compost per linear meter. Although the potential effects of N and P were partially masked by other inputs of these nutrients in the system (high concentration of nitrates in the irrigation water and phosphoric acid supplied by fertigation), an effect of P was observed the first year of study resulting in a greater plant P accumulation and in an increase in the number of fruits in the amended plots. In addition, the higher accumulation of available N and P in the topsoil at the end of the growing season indicated the potential use of this material as source of these nutrients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El trabajo contenido en esta tesis doctoral está encuadrado en el desarrollo de antenas reconfigurables electrónicamente capaces de proporcionar prestaciones competitivas a las aplicaciones cada vez más comunes que operan a frecuencias superiores a 60 GHz. En concreto, esta tesis se centra en el estudio, diseño, e implementación de las antenas reflectarray, a las que se introduce la tecnología de cristal líquido como elemento característico con el que se consigue reconfigurabilidad de haz de forma electrónica. Desde un punto de vista muy general, se puede describir un cristal líquido como un material cuya permitividad eléctrica es variable y controlada por una excitación externa, que generalmente suele corresponderse con un campo eléctrico quasi-estático (AC). Las antenas reflectarray de cristal líquido se han escogido como objeto de estudio por varias razones. La primera de ellas tiene que ver con las ventajas que los reflectarrays, y en especial aquellos realizados en configuración planar, proporcionan con respecto a otras antenas de alta ganancia como los reflectores o los “phased-arrays”. En los reflectarrays, la alimentación a través de una fuente primaria común (característica de reflectores) y el elevado número de grados de libertad de las celdas que los componen (característica de arrays) hacen que estas antenas puedan proporcionar prestaciones eléctricas iguales o mejores que las anteriores, a un coste más reducido y con estructuras de antena más compactas. La segunda razón radica en la flexibilidad que ofrece el cristal líquido a ser confinado y polarizado en recintos de geometría variada, como consecuencia de su fluidez (propiedad de los líquidos). Por ello, la tecnología de cristal líquido permite que el propio elemento reconfigurable en las celdas de reflectarray se adapte a la configuración planar de manera que en sí mismo, el cristal líquido sea una o varias de las capas características de esta configuración. Esto simplifica de forma drástica la estructura y la fabricación de este tipo de antenas, incluso si se comparan con reflectarrays reconfigurables basados en otras tecnologías como diodos, MEMS, etc. Por tanto, su coste y desarrollo es muy reducido, lo que hace que se puedan fabricar reflectarrays reconfigurables eléctricamente grandes, a bajo coste, y en producción elevada. Un ejemplo claro de una estructura similar, y que ha tenido éxito comercial, son las pantallas de cristal líquido. La tercera razón reside en el hecho de que el cristal líquido es, hasta la fecha, de las pocas tecnologías capaces de ofrecer reconfigurabilidad del haz a frecuencias superiores a 60 GHz. De hecho, el cristal líquido permite reconfigurabilidad en un amplio margen de frecuencias, que va desde DC a frecuencias del espectro visible, incluyendo las microondas y los THz. Otras tecnologías, como los materiales ferroeléctricos, el grafeno o la tecnología CMOS “on chip” permiten también conmutar el haz en estas frecuencias. Sin embargo, la tecnología CMOS tiene un elevado coste y actualmente está limitada a frecuencias inferiores a 150 GHz, y aunque los materiales ferroeléctricos o el grafeno puedan conmutar a frecuencias más altas y en un rango más amplio, tienen serias dificultades que los hacen aún inmaduros. En el caso de los materiales ferroeléctricos, los elevados voltajes para conmutar el material los hacen poco atractivos, mientras que en el caso del grafeno, su modelado aún está en discusión, y todavía no se han arrojado resultados experimentales que validen su idoneidad. Estas tres razones hacen que los reflectarrays basados en cristal líquido sean atractivos para multitud de aplicaciones de haz reconfigurable a frecuencias superiores a 60 GHz. Aplicaciones como radar de escaneo de imágenes de alta resolución, espectroscopia molecular, radiómetros para observación atmosférica, o comunicaciones inalámbricas de alta frecuencia (WiGig) son algunas de ellas. La tesis está estructurada en tres partes. En la primera de ellas se describen las características más comunes de los cristales líquidos, centrándonos en detalle en aquellas propiedades ofrecidas por este material en fase nemática. En concreto, se estudiará la anisotropía dieléctrica (Ae) de los cristales líquidos uniaxiales, que son los que se emplean en esta tesis, definida como la diferencia entre la permitividad paralela (£//) y la perpendicular (e±): Ae = e,, - e±. También se estudiará la variación de este parámetro (Ae) con la frecuencia, y el modelado electromagnético macroscópico más general que, extraído a partir de aquella, permite describir el cristal líquido para cada tensión de polarización en celdas de geometría planar. Este modelo es de suma importancia para garantizar precisión en el desfasaje proporcionado por las diferentes celdas reconfigurables para reflectarrays que se describirán en la siguiente parte de la tesis. La segunda parte de la tesis se centra en el diseño de celdas reflectarray resonantes basadas en cristal líquido. La razón por la que se escogen estos tipos de celdas reside en el hecho de que son las únicas capaces de proporcionar rangos de fase elevados ante la reducida anisotropía dieléctrica que ofrecen los cristales líquidos. El objetivo de esta parte trata, por tanto, de obtener estructuras de celdas reflectarray que sean capaces de proporcionar buenas prestaciones eléctricas a nivel de antena, mejorando sustancialmente las prestaciones de las celdas reportadas en el estado del arte, así como de desarrollar una herramienta de diseño general para aquellas. Para ello, se estudian las prestaciones eléctricas de diferentes tipos de elementos resonantes de cristal líquido que van, desde el más sencillo, que ha limitado el estado de la técnica hasta el desarrollo de esta tesis y que está formado por un sólo resonador, a elementos que constan de varios resonadores (multi-resonantes) y que pueden ser monocapa o multicapa. En un primer paso, el procedimiento de diseño de estas estructuras hace uso de un modelo convencional de cristal líquido que ha venido siendo usado en el estado del arte para este tipo de celdas, y que considera el cristal líquido como un material homogéneo e isótropo cuya permitividad varía entre (e/7) y (e±). Sin embargo, en esta parte de la tesis se demuestra que dicho modelado no es suficiente para describir de forma genérica el comportamiento del cristal líquido en las celdas tipo reflectarray. En la tesis se proponen procedimientos más exactos para el análisis y diseño basados en un modelo más general que define el cristal líquido como un material anisótropo e inhomogeneo en tres dimensiones, y se ha implementado una técnica que permite optimizar celdas multi-resonantes de forma eficiente para conseguir elevadas prestaciones en cuanto a ancho de banda, rango de fase, pérdidas, o sensibilidad al ángulo de incidencia. Los errores cometidos en el uso del modelado convencional a nivel de celda (amplitud y fase) se han analizado para varias geometrías, usando medidas de varios prototipos de antena que usan un cristal líquido real a frecuencias superiores a 100 GHz. Las medidas se han realizado en entorno periódico mediante un banco cuasi-óptico, que ha sido diseñado especialmente para este fin. Uno de estos prototipos se ha optimizado a 100 GHz para conseguir un ancho de banda relativamente elevado (10%), pérdidas reducidas, un rango de fase mayor de 360º, baja sensibilidad al ángulo de incidencia, y baja influencia de la inhomogeneidad transversal del cristal líquido en la celda. Estas prestaciones a nivel de celda superan de forma clara aquellas conseguidas por otros elementos que se han reportado en la literatura, de manera que dicho prototipo se ha usado en la última parte de la tesis para realizar diversas antenas de barrido. Finalmente, en esta parte se presenta una estrategia de caracterización de la anisotropía macroscópica a partir de medidas de los elementos de reflectarray diseñados en banco cuasi-óptico, obteniendo resultados tanto en las frecuencias de interés en RF como en AC, y comparándolas con aquellas obtenidas mediante otros métodos. La tercera parte de la tesis consiste en el estudio, diseño, fabricación y medida de antenas reconfigurables basadas en cristal líquido en configuraciones complejas. En reflectarrays pasivos, el procedimiento de diseño de la antena se limita únicamente al ajuste en cada celda de la antena de las dimensiones de las metalizaciones que se emplean para el control de fase, mediante procesos de optimización bien conocidos. Sin embargo, en el caso de reflectarrays reconfigurables basados en cristal líquido, resulta necesario un paso adicional, que consiste en calcular de forma adecuada las tensiones de control en cada celda del reflectarray para configurar la fase requerida en cada una de ellas, así como diseñar la estructura y los circuitos de control que permitan direccionar a cada elemento su tensión correspondiente. La síntesis de tensiones es por tanto igual o más importante que el diseño de la geometría de las celdas, puesto que éstas son las que están directamente relacionadas con la fase. En el estado del arte, existen varias estrategias de síntesis de tensiones que se basan en la caracterización experimental de la curva de fase respecto al voltaje. Sin embargo, esta caracterización sólo puede hacerse a un solo ángulo de incidencia y para unas determinadas dimensiones de celda, lo que produce que las tensiones sintetizadas sean diferentes de las adecuadas, y en definitiva que se alcancen errores de fase mayores de 70º. De esta forma, hasta la fecha, las prestaciones a nivel de antena que se han conseguido son reducidas en cuanto a ancho de banda, rango de escaneo o nivel de lóbulos secundarios. En esta última parte de la tesis, se introduce una nueva estrategia de síntesis de tensiones que es capaz de predecir mediante simulaciones, y con alta precisión, las tensiones que deben introducirse en cada celda teniendo en cuenta su ángulo de incidencia, sus dimensiones, la frecuencia, así como la señal de polarización definida por su frecuencia y forma de onda AC. Esta estrategia se basa en modelar cada uno de los estados de permitividad del cristal líquido como un sustrato anisótropo con inhomogeneidad longitudinal (1D), o en ciertos casos, como un tensor equivalente homogéneo. La precisión de ambos modelos electromagnéticos también se discute. Con el objetivo de obtener una herramienta eficiente de cálculo de tensiones, también se ha escrito e implementado una herramienta de análisis basada en el Método de los Momentos en el Dominio Espectral (SD-MoM) para sustratos estratificados anisótropos, que se usa en cada iteración del procedimiento de síntesis para analizar cada una de las celdas de la antena. La síntesis de tensiones se ha diseñado además para reducir al máximo el efecto del rizado de amplitud en el diagrama de radiación, que es característico en los reflectarrays que están formados por celdas con pérdidas elevadas, lo que en sí, supone un avance adicional para la obtención de mejores prestaciones de antena. Para el cálculo de los diagramas de radiación empleados en el procedimiento de síntesis, se asume un análisis elemento a elemento considerando periodicidad local, y se propone el uso de un método capaz de modelar el campo incidente de forma que se elimine la limitación de la periodicidad local en la excitación. Una vez definida la estrategia adecuada de cálculo de las tensiones a aplicar al cristal líquido en cada celda, la estructura de direccionamiento de las mismas en la antena, y diseñados los circuitos de control, se diseñan, fabrican y miden dos prototipos diferentes de antena de barrido electrónico a 100 GHz usando las celdas anteriormente presentadas. El primero de estos prototipos es un reflectarray en configuración “single offset” con capacidad de escaneo en un plano (elevación o azimut). Aunque previamente se realizan diseños de antenas de barrido en 2D a varias frecuencias en el rango de milimétricas y sub-milimétricas, y se proponen ciertas estrategias de direccionamiento que permiten conseguir este objetivo, se desarrolla el prototipo con direccionamiento en una dimensión con el fin de reducir el número de controles y posibles errores de fabricación, y así también validar la herramienta de diseño. Para un tamaño medio de apertura (con un numero de filas y columnas entre 30 y 50 elementos, lo que significa un reflectarray con un número de elementos superior a 900), la configuración “single offset” proporciona rangos de escaneo elevados, y ganancias que pueden oscilar entre los 20 y 30 dBi. En concreto, el prototipo medido proporciona un haz de barrido en un rango angular de 55º, en el que el nivel de lóbulos secundarios (SLL) permanece mejor de -13 dB en un ancho de banda de un 8%. La ganancia máxima es de 19.4 dBi. Estas prestaciones superan de forma clara aquellas conseguidas por otros autores. El segundo prototipo se corresponde con una antena de doble reflector que usa el reflectarray de cristal líquido como sub-reflector para escanear el haz en un plano (elevación o azimut). El objetivo básico de esta geometría es obtener mayores ganancias que en el reflectarray “single offset” con una estructura más compacta, aunque a expensas de reducir el rango de barrido. En concreto, se obtiene una ganancia máxima de 35 dBi, y un rango de barrido de 12º. Los procedimientos de síntesis de tensiones y de diseño de las estructuras de las celdas forman, en su conjunto, una herramienta completa de diseño precisa y eficiente de antenas reflectarray reconfigurables basados en cristales líquidos. Dicha herramienta se ha validado mediante el diseño, la fabricación y la medida de los prototipos anteriormente citados a 100 GHz, que consiguen algo nunca alcanzado anteriormente en la investigación de este tipo de antenas: unas prestaciones competitivas y una predicción excelente de los resultados. El procedimiento es general, y por tanto se puede usar a cualquier frecuencia en la que el cristal líquido ofrezca anisotropía dieléctrica, incluidos los THz. Los prototipos desarrollados en esta tesis doctoral suponen también unas de las primeras antenas de barrido real a frecuencias superiores a 100 GHz. En concreto, la antena de doble reflector para escaneo de haz es la primera antena reconfigurable electrónicamente a frecuencias superiores a 60 GHz que superan los 25 dBi de ganancia, siendo a su vez la primera antena de doble reflector que contiene un reflectarray reconfigurable como sub-reflector. Finalmente, se proponen ciertas mejoras que aún deben se deben realizar para hacer que estas antenas puedan ser un producto completamente desarrollado y competitivo en el mercado. ABSTRACT The work presented in this thesis is focused on the development of electronically reconfigurable antennas that are able to provide competitive electrical performance to the increasingly common applications operating at frequencies above 60 GHz. Specifically, this thesis presents the study, design, and implementation of reflectarray antennas, which incorporate liquid crystal (LC) materials to scan or reconfigure the beam electronically. From a general point of view, a liquid crystal can be defined as a material whose dielectric permittivity is variable and can be controlled with an external excitation, which usually corresponds with a quasi-static electric field (AC). By changing the dielectric permittivity at each cell that makes up the reflectarray, the phase shift on the aperture is controlled, so that a prescribed radiation pattern can be configured. Liquid Crystal-based reflectarrays have been chosen for several reasons. The first has to do with the advantages provided by the reflectarray antenna with respect to other high gain antennas, such as reflectors or phased arrays. The RF feeding in reflectarrays is achieved by using a common primary source (as in reflectors). This arrangement and the large number of degrees of freedom provided by the cells that make up the reflectarray (as in arrays), allow these antennas to provide a similar or even better electrical performance than other low profile antennas (reflectors and arrays), but assuming a more reduced cost and compactness. The second reason is the flexibility of the liquid crystal to be confined in an arbitrary geometry due to its fluidity (property of liquids). Therefore, the liquid crystal is able to adapt to a planar geometry so that it is one or more of the typical layers of this configuration. This simplifies drastically both the structure and manufacture of this type of antenna, even when compared with reconfigurable reflectarrays based on other technologies, such as diodes MEMS, etc. Therefore, the cost of developing this type of antenna is very small, which means that electrically large reconfigurable reflectarrays could be manufactured assuming low cost and greater productions. A paradigmatic example of a similar structure is the liquid crystal panel, which has already been commercialized successfully. The third reason lies in the fact that, at present, the liquid crystal is one of the few technologies capable of providing switching capabilities at frequencies above 60 GHz. In fact, the liquid crystal allows its permittivity to be switched in a wide range of frequencies, which are from DC to the visible spectrum, including microwaves and THz. Other technologies, such as ferroelectric materials, graphene or CMOS "on chip" technology also allow the beam to be switched at these frequencies. However, CMOS technology is expensive and is currently limited to frequencies below 150 GHz, and although ferroelectric materials or graphene can switch at higher frequencies and in a wider range, they have serious difficulties that make them immature. Ferroelectric materials involve the use of very high voltages to switch the material, making them unattractive, whereas the electromagnetic modelling of the graphene is still under discussion, so that the experimental results of devices based on this latter technology have not been reported yet. These three reasons make LC-based reflectarrays attractive for many applications that involve the use of electronically reconfigurable beams at frequencies beyond 60 GHz. Applications such as high resolution imaging radars, molecular spectroscopy, radiometers for atmospheric observation, or high frequency wireless communications (WiGig) are just some of them. This thesis is divided into three parts. In the first part, the most common properties of the liquid crystal materials are described, especially those exhibited in the nematic phase. The study is focused on the dielectric anisotropy (Ac) of uniaxial liquid crystals, which is defined as the difference between the parallel (e/7) and perpendicular (e±) permittivities: Ae = e,, - e±. This parameter allows the permittivity of a LC confined in an arbitrary volume at a certain biasing voltage to be described by solving a variational problem that involves both the electrostatic and elastic energies. Thus, the frequency dependence of (Ae) is also described and characterised. Note that an appropriate LC modelling is quite important to ensure enough accuracy in the phase shift provided by each cell that makes up the reflectarray, and therefore to achieve a good electrical performance at the antenna level. The second part of the thesis is focused on the design of resonant reflectarray cells based on liquid crystal. The reason why resonant cells have been chosen lies in the fact that they are able to provide enough phase range using the values of the dielectric anisotropy of the liquid crystals, which are typically small. Thus, the aim of this part is to investigate several reflectarray cell architectures capable of providing good electrical performance at the antenna level, which significantly improve the electrical performance of the cells reported in the literature. Similarly, another of the objectives is to develop a general tool to design these cells. To fulfill these objectives, the electrical yields of different types of resonant reflectarray elements are investigated, beginning from the simplest, which is made up of a single resonator and limits the state of the art. To overcome the electrical limitations of the single resonant cell, several elements consisting of multiple resonators are considered, which can be single-layer or multilayer. In a first step, the design procedure of these structures makes use of a conventional electromagnetic model which has been used in the literature, which considers that the liquid crystal behaves as homogeneous and isotropic materials whose permittivity varies between (e/7) y (e±). However, in this part of the thesis it is shown that the conventional modelling is not enough to describe the physical behaviour of the liquid crystal in reflectarray cells accurately. Therefore, a more accurate analysis and design procedure based on a more general model is proposed and developed, which defines the liquid crystal as an anisotropic three-dimensional inhomogeneous material. The design procedure is able to optimize multi-resonant cells efficiently to achieve good electrical performance in terms of bandwidth, phase range, losses, or sensitivity to the angle of incidence. The errors made when the conventional modelling (amplitude and phase) is considered have been also analysed for various cell geometries, by using measured results from several antenna prototypes made up of real liquid crystals at frequencies above 100 GHz. The measurements have been performed in a periodic environment using a quasi-optical bench, which has been designed especially for this purpose. One of these prototypes has been optimized to achieve a relatively large bandwidth (10%) at 100 GHz, low losses, a phase range of more than 360º, a low sensitivity to angle of incidence, and a low influence of the transversal inhomogeneity of the liquid crystal in the cell. The electrical yields of this prototype at the cell level improve those achieved by other elements reported in the literature, so that this prototype has been used in the last part of the thesis to perform several complete antennas for beam scanning applications. Finally, in this second part of the thesis, a novel strategy to characterise the macroscopic anisotropy using reflectarray cells is presented. The results in both RF and AC frequencies are compared with those obtained by other methods. The third part of the thesis consists on the study, design, manufacture and testing of LCbased reflectarray antennas in complex configurations. Note that the design procedure of a passive reflectarray antenna just consists on finding out the dimensions of the metallisations of each cell (which are used for phase control), using well-known optimization processes. However, in the case of reconfigurable reflectarrays based on liquid crystals, an additional step must be taken into account, which consists of accurately calculating the control voltages to be applied to each cell to configure the required phase-shift distribution on the surface of the antenna. Similarly, the structure to address the voltages at each cell and the control circuitry must be also considered. Therefore, the voltage synthesis is even more important than the design of the cell geometries (dimensions), since the voltages are directly related to the phase-shift. Several voltage synthesis procedures have been proposed in the state of the art, which are based on the experimental characterization of the phase/voltage curve. However, this characterization can be only carried out at a single angle of incidence and at certain cell dimensions, so that the synthesized voltages are different from those needed, thus giving rise to phase errors of more than 70°. Thus, the electrical yields of the LCreflectarrays reported in the literature are limited in terms of bandwidth, scanning range or side lobes level. In this last part of the thesis, a new voltage synthesis procedure has been defined and developed, which allows the required voltage to be calculated at each cell using simulations that take into account the particular dimensions of the cells, their angles of incidence, the frequency, and the AC biasing signal (frequency and waveform). The strategy is based on the modelling of each one of the permittivity states of the liquid crystal as an anisotropic substrate with longitudinal inhomogeneity (1D), or in certain cases, as an equivalent homogeneous tensor. The accuracy of both electromagnetic models is also discussed. The phase errors made by using the proposed voltage synthesis are better than 7º. In order to obtain an efficient tool to analyse and design the reflectarray, an electromagnetic analysis tool based on the Method of Moments in the spectral domain (SD-MoM) has also written and developed for anisotropic stratified media, which is used at each iteration of the voltage synthesis procedure. The voltage synthesis is also designed to minimize the effect of amplitude ripple on the radiation pattern, which is typical of reflectarrays made up of cells exhibiting high losses and represents a further advance in achieving a better antenna performance. To calculate the radiation patterns used in the synthesis procedure, an element-by-element analysis is assumed, which considers the local periodicity approach. Under this consideration, the use of a novel method is proposed, which avoids the limitation that the local periodicity imposes on the excitation. Once the appropriate strategy to calculate the voltages to be applied at each cell is developed, and once it is designed and manufactured both the structure to address the voltages to the antenna and the control circuits, two complete LC-based reflectarray antennas that operate at 100 GHz have been designed, manufactured and tested using the previously presented cells. The first prototype consists of a single offset reflectarray with beam scanning capabilities on one plane (elevation and azimuth). Although several LC-reflectarray antennas that provide 2-D scanning capabilities are also designed, and certain strategies to achieve the 2-D addressing of the voltage are proposed, the manufactured prototype addresses the voltages in one dimension in order to reduce the number of controls and manufacturing errors, and thereby validating the design tool. For an average aperture size (with a number of rows and columns of between 30 and 50 elements, which means a reflectarray with more than 900 cells), the single offset configuration provides an antenna gain of between 20 and 30 dBi and a large scanning range. The prototype tested at 100 GHz exhibits an electronically scanned beam in an angular range of 55º and 8% of bandwidth, in which the side lobe level (SLL) remains better than -13 dB. The maximum gain is 19.4 dBi. The electrical performance of the antenna is clearly an improvement on those achieved by other authors in the state of the art. The second prototype corresponds to a dual reflector antenna with a liquid crystal-based reflectarray used as a sub-reflector for beam scanning in one plane (azimuth or elevation). The main objective is to obtain a higher gain than that provided by the single offset configuration, but using a more compact architecture. In this case, a maximum gain of 35 dBi is achieved, although at the expense of reducing the scanning range to 12°, which is inherent in this type of structure. As a general statement, the voltage synthesis and the design procedure of the cells, jointly make up a complete, accurate and efficient design tool of reconfigurable reflectarray antennas based on liquid crystals. The tool has been validated by testing the previously mentioned prototypes at 100 GHz, which achieve something never reached before for this type of antenna: a competitive electrical performance, and an excellent prediction of the results. The design procedure is general and therefore can be used at any frequency for which the liquid crystal exhibits dielectric anisotropy. The two prototypes designed, manufactured and tested in this thesis are also some of the first antennas that currently operate at frequencies above 100 GHz. In fact, the dual reflector antenna is the first electronically scanned dual reflector antenna at frequencies above 60 GHz (the operation frequency is 100 GHz) with a gain greater than 25 dBi, being in turn the first dual-reflector antenna with a real reconfigurable sub-reflectarray. Finally, some improvements that should be still investigated to make these antennas commercially competitive are proposed.