85 resultados para coal-fired power plant


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the Three Mile Island accident, an important focus of pressurized water reactor (PWR) transient analyses has been a small-break loss-of-coolant accident (SBLOCA). In 2002, the discovery of thinning of the vessel head wall at the Davis Besse nuclear power plant reactor indicated the possibility of an SBLOCA in the upper head of the reactor vessel as a result of circumferential cracking of a control rod drive mechanism penetration nozzle - which has cast even greater importance on the study of SBLOCAs. Several experimental tests have been performed at the Large Scale Test Facility to simulate the behavior of a PWR during an upper-head SBLOCA. The last of these tests, Organisation for Economic Co-operation and Development Nuclear Energy Agency Rig of Safety Assessment (OECD/NEA ROSA) Test 6.1, was performed in 2005. This test was simulated with the TRACE 5.0 code, and good agreement with the experimental results was obtained. Additionally, a broad analysis of an upper-head SBLOCA with high-pressure safety injection failed in a Westinghouse PWR was performed taking into account different accident management actions and conditions in order to check their suitability. This issue has been analyzed also in the framework of the OECD/NEA ROSA project and the Code Applications and Maintenance Program (CAMP). The main conclusion is that the current emergency operating procedures for Westinghouse reactor design are adequate for these kinds of sequences, and they do not need to be modified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the current preparatory phase of the European laser fusion project HiPER, an intensive effort has being placed to identify an armour material able to protect the internal walls of the chamber against the high thermal loads and high fluxes of x-rays and ions produced during the fusion explosions. This poster addresses the different threats and limitations of a poly-crystalline Tungsten armour. The analysis is carried out under the conditions of an experimental chamber hypothetically constructed to demonstrate laser fusion in a repetitive mode, subjected to a few thousand 48MJ shock ignition shots during its entire lifetime. If compared to the literature, an extrapolation of the thermomechanical and atomistic effects obtained from the simulations of the experimental chamber to the conditions of a Demo reactor (working 24/7 at hundreds of MW) or a future power plant (producing GW) suggests that “standard” tungsten will not be a suitable armour. Thus, new materials based on nano-structured W and C are being investigated as possible candidates. The research programme launched by the HiPER material team is introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, computer simulators are becoming basic tools for education and training in many engineering fields. In the nuclear industry, the role of simulation for training of operators of nuclear power plants is also recognized of the utmost relevance. As an example, the International Atomic Energy Agency sponsors the development of nuclear reactor simulators for education, and arranges the supply of such simulation programs. Aware of this, in 2008 Gas Natural Fenosa, a Spanish gas and electric utility that owns and operate nuclear power plants and promotes university education in the nuclear technology field, provided the Department of Nuclear Engineering of Universidad Politécnica de Madrid with the Interactive Graphic Simulator (IGS) of “José Cabrera” (Zorita) nuclear power plant, an industrial facility whose commercial operation ceased definitively in April 2006. It is a state-of-the-art full-scope real-time simulator that was used for training and qualification of the operators of the plant control room, as well as to understand and analyses the plant dynamics, and to develop, qualify and validate its emergency operating procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmental constraints imposed on hydropoweroperation are usually given in the form of minimum environmental flows and maximum and minimum rates of change of flows, or ramp rates. One solution proposed to mitigate the environmental impact caused by the flows discharged by a hydropower plant while reducing the economic impact of the above-mentioned constraints consists in building a re-regulationreservoir, or afterbay, downstream of the power plant. Adding pumpingcapability between the re-regulationreservoir and the main one could contribute both to reducing the size of the re-regulationreservoir, with the consequent environmental improvement, and to improving the economic feasibility of the project, always fulfilling the environmental constraints imposed to hydropoweroperation. The objective of this paper is studying the contribution of a re-regulationreservoir to fulfilling the environmental constraints while reducing the economic impact of said constraints. For that purpose, a revenue-driven optimization model based on mixed integer linear programming is used. Additionally, the advantages of adding pumpingcapability are analysed. In order to illustrate the applicability of the methodology, a case study based on a real hydropower plant is presented

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los terremotos constituyen una de las más importantes fuentes productoras de cargas dinámicas que actúan sobre las estructuras y sus cimentaciones. Cuando se produce un terremoto la energía liberada genera movimientos del terreno en forma de ondas sísmicas que pueden provocar asientos en las cimentaciones de los edificios, empujes sobre los muros de contención, vuelco de las estructuras y el suelo puede licuar perdiendo su capacidad de soporte. Los efectos de los terremotos en estructuras constituyen unos de los aspectos que involucran por su condición de interacción sueloestructura, disciplinas diversas como el Análisis Estructural, la Mecánica de Suelo y la Ingeniería Sísmica. Uno de los aspectos que han sido poco estudiados en el cálculo de estructuras sometidas a la acciones de los terremotos son los efectos del comportamiento no lineal del suelo y de los movimientos que pueden producirse bajo la acción de cargas sísmicas, tales como posibles despegues y deslizamientos. En esta Tesis se estudian primero los empujes sísmicos y posibles deslizamientos de muros de contención y se comparan las predicciones de distintos tipos de cálculos: métodos pseudo-estáticos como el de Mononobe-Okabe (1929) con la contribución de Whitman-Liao (1985), y formulaciones analíticas como la desarrollada por Veletsos y Younan (1994). En segundo lugar se estudia el efecto del comportamiento no lineal del terreno en las rigideces de una losa de cimentación superficial y circular, como la correspondiente a la chimenea de una Central Térmica o al edificio del reactor de una Central Nuclear, considerando su variación con frecuencia y con el nivel de cargas. Finalmente se estudian los posibles deslizamientos y separación de las losas de estas dos estructuras bajo la acción de terremotos, siguiendo la formulación propuesta por Wolf (1988). Para estos estudios se han desarrollado una serie de programas específicos (MUROSIS, VELETSOS, INTESES y SEPARSE) cuyos listados y detalles se incluyen en los Apéndices. En el capítulo 6 se incluyen las conclusiones resultantes de estos estudios y recomendaciones para futuras investigaciones. ABSTRACT Earthquakes constitute one of the most important sources of dynamic loads that acting on structures and foundations. When an earthquake occurs the liberated energy generates seismic waves that can give rise to structural vibrations, settlements of the foundations of buildings, pressures on retaining walls, and possible sliding, uplifting or even overturning of structures. The soil can also liquefy losing its capacity of support The study of the effects of earthquakes on structures involve the use of diverse disciplines such as Structural Analysis, Soil Mechanics and Earthquake Engineering. Some aspects that have been the subject of limited research in relation to the behavior of structures subjected to earthquakes are the effects of nonlinear soil behavior and geometric nonlinearities such as sliding and uplifting of foundations. This Thesis starts with the study of the seismic pressures and potential displacements of retaining walls comparing the predictions of two types of formulations and assessing their range of applicability and limitations: pseudo-static methods as proposed by Mononobe-Okabe (1929), with the contribution of Whitman-Liao (1985), and analytical formulations as the one developed by Veletsos and Younan (1994) for rigid walls. The Thesis deals next with the effects of nonlinear soil behavior on the dynamic stiffness of circular mat foundations like the chimney of a Thermal Power Station or the reactor building of a Nuclear Power Plant, as a function of frequency and level of forces. Finally the seismic response of these two structures accounting for the potential sliding and uplifting of the foundation under a given earthquake are studied, following an approach suggested by Wolf (1988). In order to carry out these studies a number of special purposes computer programs were developed (MUROSIS, VELETSOS, INTESES and SEPARSE). The listing and details of these programs are included in the appendices. The conclusions derived from these studies and recommendations for future work are presented in Chapter 6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En la actualidad, el interés por las plantas de potencia de ciclo combinado de gas y vapor ha experimentado un notable aumento debido a su alto rendimiento, bajo coste de generación y rápida construcción. El objetivo fundamental de la tesis es profundizar en el conocimiento de esta tecnología, insuficientemente conocida hasta el momento debido al gran número de grados de libertad que existen en el diseño de este tipo de instalaciones. El estudio se realizó en varias fases. La primera consistió en analizar y estudiar las distintas tecnologías que se pueden emplear en este tipo de centrales, algunas muy recientes o en fase de investigación, como las turbinas de gas de geometría variable, las turbinas de gas refrigeradas con agua o vapor del ciclo de vapor o las calderas de paso único que trabajan con agua en condiciones supercríticas. Posteriormente se elaboraron los modelos matemáticos que permiten la simulación termodinámica de cada uno de los componentes que integran las plantas, tanto en el punto de diseño como a cargas parciales. Al mismo tiempo, se desarrolló una metodología novedosa que permite resolver el sistema de ecuaciones que resulta de la simulación de cualquier configuración posible de ciclo combinado. De esa forma se puede conocer el comportamiento de cualquier planta en cualquier punto de funcionamiento. Por último se desarrolló un modelo de atribución de costes para este tipo de centrales. Con dicho modelo, los estudios se pueden realizar no sólo desde un punto de vista termodinámico sino también termoeconómico, con lo que se pueden encontrar soluciones de compromiso entre rendimiento y coste, asignar costes de producción, determinar curvas de oferta, beneficios económicos de la planta y delimitar el rango de potencias donde la planta es rentable. El programa informático, desarrollado en paralelo con los modelos de simulación, se ha empleado para obtener resultados de forma intensiva. El estudio de los resultados permite profundizar ampliamente en el conocimiento de la tecnología y, así, desarrollar una metodología de diseño de este tipo de plantas bajo un criterio termoeconómico. ABSTRACT The growing energy demand and the need of shrinking costs have led to the design of high efficiency and quick installation power plants. The success of combined cycle gas turbine power plants lies on their high efficiency, low cost and short construction lead time. The main objective of the work is to study in detail this technology, which is not thoroughly known owing to the great number of degrees of freedom that exist in the design of this kind of power plants. The study is divided into three parts. Firstly, the different technologies and components that could be used in any configuration of a combined cycle gas turbine power plant are studied. Some of them could be of recent technology, such as the variable inlet guide vane compressors, the H-technology for gas turbine cooling or the once-through heat recovery steam generators, used with water at supercritical conditions. Secondly, a mathematical model has been developed to simulate at full and part load the components of the power plant. At the same time, a new methodology is proposed in order to solve the equation system resulting for any possible power plant configuration. Therefore, any combined cycle gas turbine could be simulated at any part load condition. Finally a themoeconomic model is proposed. This model allows studying the power plant not only from a thermodynamic point of view but also from a thermoeconomic one. Likewise, it allows determining the generating costs or the cash flow, thus achieving a trade off between efficiency and cost. Likewise, the model calculates the part load range where the power plant is profitable. Once the thermodynamic and thermoeconomic models are developed, they are intensively used in order to gain knowledge in the combined cycle gas turbine technology and, in this way, to propose a methodology aimed at the design of this kind of power plants from a thermoeconomic point of view.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of photovoltaic experimental plants in engineering educational buildings contributes to an increase in acceptance of this technology by future engineers. There are some photovoltaic (PV) systems in educational buildings in Spain, but they are usually limited to buildings in relation to electrical technologies or research areas. They are not common in other educational or official buildings. This paper presents the project of a grid-connected solar plant with two main objectives. First, different PV module technologies will be compared. Second, an emphasis on agronomical areas in educational settings will be reviewed in an attempt to facilitate student engagement in the use of the power plant. The system is grid-connected in order to pay-back the investment in the plant. In fact the electricity generated by the plant will be used by the installations of the building, as it is the closest consumer. This work intends to approximate photovoltaic technology to university degrees not directly related with it and at the same time research in comparison of systems with different technologies. This is a good example of an solar plant for both optimum production and educational purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the case of large burnup, a control rod (CR) guide tube in the pressurized water reactor of a commercial nuclear power plant might bend. As a consequence, a CR drop experiment may indicate an event of a CR partially inserted and whether the CR should be deemed inoperable. Early prevention of such an event can be achieved by measuring two friction coefficients: the hydraulic coefficient and the sliding coefficient. The hydraulic coefficient hardly changes, so that the curvature of the guide tube can only be detected thanks to a variation of the sliding coefficient. A simple model for the CR drop is established and validated with CR drop experiments. If tmx denotes the instant of CR maximum velocity, a linear relationship between (tmx)_2 and the sliding coefficient is found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficiency of the Iberian Energy Derivatives Market in its first five and a half years is assessed in terms of volume, open interest and price. The continuous market shows steady liquidity growth. Its volume is strongly correlated to that of the Over The Counter (OTC) market, the amount of market makers, the enrolment of financial agents and generation companies belonging to the integrated group of last resort suppliers, and the OTC cleared volume in its clearing house. The hedging efficiency, measured through the ratio between the final open interest and the cleared volume, shows the lowest values for the Spanish base load futures as they are the most liquid contracts. The ex-post forward risk premium has diminished due to the learning curve and the effect of the fixed price retributing the indigenous coal fired generation. This market is quite less developed than the European leaders headquartered in Norway and Germany. Enrolment of more traders, mainly international energy companies, financial agents, energy intensive industries and renewable generation companies is desired. Market monitoring reports by the market operator providing post-trade transparency, OTC data access by the energy regulator, and assessment of the regulatory risk can contribute to efficiency gains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Las cuestiones relacionadas con el transporte de residuos radiactivos de alta actividad (RAA) al previsto almacén temporal centralizado (ATC) en Villar de Cañas (Cuenca) están de actualidad, debido a la movilidad que se espera en un futuro próximo, el compromiso con el medio ambiente, la protección de las personas, así, como la normativa legal reguladora. En esta tesis se ha evaluado el impacto radiológico asociado a este tipo de transportes mediante una nueva herramienta de procesamiento de datos, que puede ser de utilidad y servir como documentación complementaria a la recogida en el marco legal del transporte. Además puede facilitar el análisis desde una perspectiva más científica, para investigadores, responsables públicos y técnicos en general, que pueden utilizar dicha herramienta para simular distintos escenarios de transportes radiactivos basados únicamente en datos de los materiales de entrada y las rutas elegidas. Así, conociendo el nivel de radiación a un metro del transporte y eligiendo una ruta, obtendremos los impactos asociados, tales como las poblaciones afectadas, la dosis recibida por la persona más expuesta, el impacto radiológico global, las dosis a la población en el trayecto y el posible detrimento de su salud. En España se prevé una larga “ruta radiactiva” de más de 2.000 kilómetros, por la que el combustible nuclear gastado se transportará presumiblemente por carretera desde las centrales nucleares hasta el ATC, así como los residuos vitrificados procedentes del reprocesado del combustible de la central nuclear Vandellos I, que en la actualidad están en Francia. Como conclusión más importante, se observa que la emisión de radiaciones ionizantes procedentes del transporte de residuos radiactivos de alta actividad en España, en operación normal, no es significativa a la hora de generar efectos adversos en la salud humana y su impacto radiológico puede considerarse despreciable. En caso de accidente, aunque la posibilidad del suceso es remota, las emisiones, no serán determinantes a la hora de generar efectos adversos en la salud humana. Issues related to the transport of high level radioactive wastes (HLW) to the new centralised temporary storage facility to be built in Villar de Cañas (Cuenca) are attracting renewed attention due to the mobility expected in the near future for these materials, the commitment to the environment, the protection of persons and the legal regulatory standards. This study assesses the radiological impacts associated with this type of transport by means of a new dataprocessing tool, which may be of use and serve as documentation complementary to that included in the legal framework covering transport. Furthermore, it may facilitate analysis from a more scientific perspective for researchers, public servants and technicians in general, who may use the tool to simulate different radioactive transport scenarios based only on input materials data and the routes selected. Thus, by knowing the radiation level at a distance of one metre from the transport and selecting a route, it is possible to obtain the associated impacts, such as the affected populations, the dose received by the most exposed individual, the overall radiological impact and the doses to the public en route and the possible detriment to their health. In Spain a long “radioactive route” of more than 2,000 kilometres is expected, along which spent nuclear fuels will be transported – foreseeably by road – from the nuclear power plants to the CTS facility. The route will also be used for the vitrified wastes from fuel reprocessing of the fuel from Vandellós I nuclear power plant, which are currently in France. In conclusion, it may be observed that the emission of ionising radiations from transport of high level radioactive wastes in Spain is insignificant, in normal operations, as regards the generation of adverse effects for human health, and that the radiological impact may be considered negligible. In the event of an accident, the possibility of which is remote, the emissions will not be also a very determining factor as regards adverse effects for human health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to complement ISFOC’s characterization capabilities, a Helios 3198 CPV Solar Simulator was installed in summer 2010. This Solar Simulator, based on a parabolic mirror and a high-intensity, small area Xenon flash lamp was developed by the Instituto de Energía Solar in Madrid [1] and is manufactured and distributed by Soldaduras Avanzadas [2]. This simulator is used not only for R&D purposes, but as a quality control tool for incoming modules that are to be installed in ISFOC’s CPV plants. In this paper we will discuss the results of recent measurements of close to 5000 modules, the entire production of modules corresponding to a small CPV power plant (200 kWp). We scrutinize the resultant data for signs of drift in the measurements, and analyze the light quality before and after, to check for changes in spectrum or spatial uniformity.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design of nuclear power plant has to follow a number of regulations aimed at limiting the risks inherent in this type of installation. The goal is to prevent and to limit the consequences of any possible incident that might threaten the public or the environment. To verify that the safety requirements are met a safety assessment process is followed. Safety analysis is as key component of a safety assessment, which incorporates both probabilistic and deterministic approaches. The deterministic approach attempts to ensure that the various situations, and in particular accidents, that are considered to be plausible, have been taken into account, and that the monitoring systems and engineered safety and safeguard systems will be capable of ensuring the safety goals. On the other hand, probabilistic safety analysis tries to demonstrate that the safety requirements are met for potential accidents both within and beyond the design basis, thus identifying vulnerabilities not necessarily accessible through deterministic safety analysis alone. Probabilistic safety assessment (PSA) methodology is widely used in the nuclear industry and is especially effective in comprehensive assessment of the measures needed to prevent accidents with small probability but severe consequences. Still, the trend towards a risk informed regulation (RIR) demanded a more extended use of risk assessment techniques with a significant need to further extend PSA’s scope and quality. Here is where the theory of stimulated dynamics (TSD) intervenes, as it is the mathematical foundation of the integrated safety assessment (ISA) methodology developed by the CSN(Consejo de Seguridad Nuclear) branch of Modelling and Simulation (MOSI). Such methodology attempts to extend classical PSA including accident dynamic analysis, an assessment of the damage associated to the transients and a computation of the damage frequency. The application of this ISA methodology requires a computational framework called SCAIS (Simulation Code System for Integrated Safety Assessment). SCAIS provides accident dynamic analysis support through simulation of nuclear accident sequences and operating procedures. Furthermore, it includes probabilistic quantification of fault trees and sequences; and integration and statistic treatment of risk metrics. SCAIS comprehensively implies an intensive use of code coupling techniques to join typical thermal hydraulic analysis, severe accident and probability calculation codes. The integration of accident simulation in the risk assessment process and thus requiring the use of complex nuclear plant models is what makes it so powerful, yet at the cost of an enormous increase in complexity. As the complexity of the process is primarily focused on such accident simulation codes, the question of whether it is possible to reduce the number of required simulation arises, which will be the focus of the present work. This document presents the work done on the investigation of more efficient techniques applied to the process of risk assessment inside the mentioned ISA methodology. Therefore such techniques will have the primary goal of decreasing the number of simulation needed for an adequate estimation of the damage probability. As the methodology and tools are relatively recent, there is not much work done inside this line of investigation, making it a quite difficult but necessary task, and because of time limitations the scope of the work had to be reduced. Therefore, some assumptions were made to work in simplified scenarios best suited for an initial approximation to the problem. The following section tries to explain in detail the process followed to design and test the developed techniques. Then, the next section introduces the general concepts and formulae of the TSD theory which are at the core of the risk assessment process. Afterwards a description of the simulation framework requirements and design is given. Followed by an introduction to the developed techniques, giving full detail of its mathematical background and its procedures. Later, the test case used is described and result from the application of the techniques is shown. Finally the conclusions are presented and future lines of work are exposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct Steam Generation (DSG) in Linear Fresnel (LF) solar collectors is being consolidated as a feasible technology for Concentrating Solar Power (CSP) plants. The competitiveness of this technology relies on the following main features: water as heat transfer fluid (HTF) in Solar Field (SF), obtaining high superheated steam temperatures and pressures at turbine inlet (500ºC and 90 bar), no heat tracing required to avoid HTF freezing, no HTF degradation, no environmental impacts, any heat exchanger between SF and Balance Of Plant (BOP), and low cost installation and maintenance. Regarding to LF solar collectors, were recently developed as an alternative to Parabolic Trough Collector (PTC) technology. The main advantages of LF are: the reduced collector manufacturing cost and maintenance, linear mirrors shapes versus parabolic mirror, fixed receiver pipes (no ball joints reducing leaking for high pressures), lower susceptibility to wind damages, and light supporting structures allowing reduced driving devices. Companies as Novatec, Areva, Solar Euromed, etc., are investing in LF DSG technology and constructing different pilot plants to demonstrate the benefits and feasibility of this solution for defined locations and conditions (Puerto Errado 1 and 2 in Murcia Spain, Lidellin Newcastle Australia, Kogran Creek in South West Queensland Australia, Kimberlina in Bakersfield California USA, Llo Solar in Pyrénées France,Dhursar in India,etc). There are several critical decisions that must be taken in order to obtain a compromise and optimization between plant performance, cost, and durability. Some of these decisions go through the SF design: proper thermodynamic operational parameters, receiver material selection for high pressures, phase separators and recirculation pumps number and location, pipes distribution to reduce the amount of tubes (reducing possible leaks points and transient time, etc.), etc. Attending to these aspects, the correct design parameters selection and its correct assessment are the main target for designing DSG LF power plants. For this purpose in the recent few years some commercial software tools were developed to simulatesolar thermal power plants, the most focused on LF DSG design are Thermoflex and System Advisor Model (SAM). Once the simulation tool is selected,it is made the study of the proposed SFconfiguration that constitutes the main innovation of this work, and also a comparison with one of the most typical state-of-the-art configuration. The transient analysis must be simulated with high detail level, mainly in the BOP during start up, shut down, stand by, and partial loads are crucial, to obtain the annual plant performance. An innovative SF configurationwas proposed and analyzed to improve plant performance. Finally it was demonstrated thermal inertia and BOP regulation mode are critical points in low sun irradiation day plant behavior, impacting in annual performance depending on power plant location.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance efficiency of electrodynamic bare tethers acting as thrusters in low Earth orbit, as gauged by the ratio of the system mass dedicated to thrust over mission impulse, is analyzed and compared to the performance efficiency of electrical thrusters. Tether systems are much lighter for times beyond six months in space-tug operations, where there is a dedicated solar array, and beyond one month for reboost of the International Space Station, where the solar array is already in place. Bare-tether propulsive efficiency itself, with the tether considered as part of the power plant, is higher for space tugs. Tether optimization shows that thin tapes have greater propulsive efficiency and are less sensitive to plasma density variations in orbit than cylindrical tethers. The efficiency increases with tape length if some segment next to the power supply at the top is insulated to make the tether potential bias vanish at the lower end; multitape tethers must be used to keep the efficiency high at high thrust levels. The efficiency has a maximum for tether-hardware mass equal to the fraction of power-subsystem mass going into ohmic power, though the maximum is very flat. For space tugs, effects of induced-bias changes in orbit might need to be reduced by choosing a moderately large power-subsystem to tether-hardware mass ratio or by tracking the current-voltage characteristic of the solar array.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este Proyecto estudia la implantación de una central termoeléctrica para la generación de energía en la provincia de Orense. Se trata de una instalación que hace uso de biomasa forestal con el fin de producir energía eléctrica renovable de una manera responsable. En primer lugar se estudia en profundidad la disponibilidad de la biomasa presente en la región que dará lugar al emplazamiento de la instalación, en pos de una posterior toma de decisión acerca del correcto dimensionamiento de la planta, así como la ubicación óptima de la misma. Se ha logrado dar una alternativa a la dependencia energética a partir de una energía renovable limpia, como la cadena integrada de producción eléctrica. Considerando con rigor tanto las políticas de globalización regionales como internacionales orientadas a lograr un desarrollo sostenible y a la lucha contra el cambio climático, como la cadena integrada de producción eléctrica. Una vez puestos en situación, se analiza las diferentes técnicas utilizadas para el aprovechamiento energético con la biomasa disponible. Se trata de encontrar la mejor alternativa capaz de optimizar los recursos energéticos de la zona para la generación de energía eléctrica. Abstract This project is based on the study of a power plant located in the province of Ourense and its fundamental target is aimed to the generation of electricity. The importance of this plant is its commitment within renewable resources that enhance the use of forest biomass in order to produce electrical power in a responsible way. In the first place, it is necessary to deeply investigate the characteristics of the available biomass present in the place of interest, which will define the size and location of the power plant. This project gives an alternative to the energetic dependence from a renewable point of view, considering rigorously globalized politics intended for a sustainable energetic progress within the introduction of ambitious measures against climate change.