36 resultados para Water improvement to decrease the fluoride level


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Melon is traditionally cultivated in fertigated farmlands in the center of Spain with high inputs of water and N fertilizer. Excess N can have a negative impact, from the economic point of view, since it can diminish the production and quality of the fruit, from the environmental point of view, since it is a very mobile element in the soil and can contaminate groundwater. From health point of view, nitrate can be accumulated in fruit pulp, and, in addition, groundwater is the fundamental supply source of human populations. Best management practices are particularly necessary in this region as many zones have been declared vulnerable to NO3- pollution (Directive 91/676/CEE) During successive years, a melon crop (Cucumis melo L.) was grown under field conditions applying mineral and organic fertilizers under drip irrigation. Different doses of ammonium nitrate were used as well as compost derived from the wine-distillery industry which is relevant in this area. The present study reviews the most common N efficiency indexes under the different management options with a view to maximizing yield and minimizing N loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urban mobility in Europe is always a responsibility of the municipalities which propose measures to reduce CO2 emissions in terms of mobility aimed at reducing individual private transport (car). The European Commission's Action Plan on Urban Mobility calls for an increase in the take-up of Sustainable Urban Mobility Plans in Europe. SUMPs aim to create a sustainable urban transport system. Europe has got some long term initiatives and has been using some evaluation procedures, many of them through European projects. Nevertheless, the weak point with the SUMPs in Spain, has been the lack of concern about the evaluation and the effectiveness of the measures implemented in a SUMP. For this reason, it is difficult to know exactly whether or not the SUMPs have positively influenced in the modal split of the cities, and its contribution to reduce CO2 levels. The case of the City of Burgos is a very illustrative example as it developed a CiViTAS project during the years 2005-2009, with a total investment of 6M?. The results have been considered as ?very successful? even at European level. The modal split has changed considerably for better, The cost-effectiveness ratio of the SUMP in the city can be measured with the CO2 ton saved, specifically 36 ? per CO2 ton saved, which is fully satisfactory and in line with calculations from other European researchers. Additionally, the authors propose a single formula to measure the effectiveness of the activities developed under the umbrella of a SUMP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El desarrollo da las nuevas tecnologías permite a los ingenieros llevar al límite el funcionamiento de los circuitos integrados (Integrated Circuits, IC). Las nuevas generaciones de procesadores, DSPs o FPGAs son capaces de procesar la información a una alta velocidad, con un alto consumo de energía, o esperar en modo de baja potencia con el mínimo consumo posible. Esta gran variación en el consumo de potencia y el corto tiempo necesario para cambiar de un nivel al otro, afecta a las especificaciones del Módulo de Regulador de Tensión (Voltage Regulated Module, VRM) que alimenta al IC. Además, las características adicionales obligatorias, tales como adaptación del nivel de tensión (Adaptive Voltage Positioning, AVP) y escalado dinámico de la tensión (Dynamic Voltage Scaling, DVS), imponen requisitos opuestas en el diseño de la etapa de potencia del VRM. Para poder soportar las altas variaciones de los escalones de carga, el condensador de filtro de salida del VRM se ha de sobredimensionar, penalizando la densidad de energía y el rendimiento durante la operación de DVS. Por tanto, las actuales tendencias de investigación se centran en mejorar la respuesta dinámica del VRM, mientras se reduce el tamaño del condensador de salida. La reducción del condensador de salida lleva a menor coste y una prolongación de la vida del sistema ya que se podría evitar el uso de condensadores voluminosos, normalmente implementados con condensadores OSCON. Una ventaja adicional es que reduciendo el condensador de salida, el DVS se puede realizar más rápido y con menor estrés de la etapa de potencia, ya que la cantidad de carga necesaria para cambiar la tensión de salida es menor. El comportamiento dinámico del sistema con un control lineal (Control Modo Tensión, VMC, o Control Corriente de Pico, Peak Current Mode Control, PCMC,…) está limitado por la frecuencia de conmutación del convertidor y por el tamaño del filtro de salida. La reducción del condensador de salida se puede lograr incrementando la frecuencia de conmutación, así como incrementando el ancho de banda del sistema, y/o aplicando controles avanzados no-lineales. Usando esos controles, las variables del estado se saturan para conseguir el nuevo régimen permanente en un tiempo mínimo, así como el filtro de salida, más específicamente la pendiente de la corriente de la bobina, define la respuesta de la tensión de salida. Por tanto, reduciendo la inductancia de la bobina de salida, la corriente de bobina llega más rápido al nuevo régimen permanente, por lo que una menor cantidad de carga es tomada del condensador de salida durante el tránsito. El inconveniente de esa propuesta es que el rendimiento del sistema es penalizado debido al incremento de pérdidas de conmutación y las corrientes RMS. Para conseguir tanto la reducción del condensador de salida como el alto rendimiento del sistema, mientras se satisfacen las estrictas especificaciones dinámicas, un convertidor multifase es adoptado como estándar para aplicaciones VRM. Para asegurar el reparto de las corrientes entre fases, el convertidor multifase se suele implementar con control de modo de corriente. Para superar la limitación impuesta por el filtro de salida, la segunda posibilidad para reducir el condensador de salida es aplicar alguna modificación topológica (Topologic modifications) de la etapa básica de potencia para incrementar la pendiente de la corriente de bobina y así reducir la duración de tránsito. Como el transitorio se ha reducido, una menor cantidad de carga es tomada del condensador de salida bajo el mismo escalón de la corriente de salida, con lo cual, el condensador de salida se puede reducir para lograr la misma desviación de la tensión de salida. La tercera posibilidad para reducir el condensador de salida del convertidor es introducir un camino auxiliar de energía (additional energy path, AEP) para compensar el desequilibrio de la carga del condensador de salida reduciendo consecuentemente la duración del transitorio y la desviación de la tensión de salida. De esta manera, durante el régimen permanente, el sistema tiene un alto rendimiento debido a que el convertidor principal con bajo ancho de banda es diseñado para trabajar con una frecuencia de conmutación moderada para conseguir requisitos estáticos. Por otro lado, el comportamiento dinámico durante los transitorios es determinado por el AEP con un alto ancho de banda. El AEP puede ser implementado como un camino resistivo, como regulador lineal (Linear regulator, LR) o como un convertidor conmutado. Las dos primeras implementaciones proveen un mayor ancho de banda, acosta del incremento de pérdidas durante el transitorio. Por otro lado, la implementación del convertidor computado presenta menor ancho de banda, limitado por la frecuencia de conmutación, aunque produce menores pérdidas comparado con las dos anteriores implementaciones. Dependiendo de la aplicación, la implementación y la estrategia de control del sistema, hay una variedad de soluciones propuestas en el Estado del Arte (State-of-the-Art, SoA), teniendo diferentes propiedades donde una solución ofrece más ventajas que las otras, pero también unas desventajas. En general, un sistema con AEP ideal debería tener las siguientes propiedades: 1. El impacto del AEP a las pérdidas del sistema debería ser mínimo. A lo largo de la operación, el AEP genera pérdidas adicionales, con lo cual, en el caso ideal, el AEP debería trabajar por un pequeño intervalo de tiempo, solo durante los tránsitos; la otra opción es tener el AEP constantemente activo pero, por la compensación del rizado de la corriente de bobina, se generan pérdidas innecesarias. 2. El AEP debería ser activado inmediatamente para minimizar la desviación de la tensión de salida. Para conseguir una activación casi instantánea, el sistema puede ser informado por la carga antes del escalón o el sistema puede observar la corriente del condensador de salida, debido a que es la primera variable del estado que actúa a la perturbación de la corriente de salida. De esa manera, el AEP es activado con casi cero error de la tensión de salida, logrando una menor desviación de la tensión de salida. 3. El AEP debería ser desactivado una vez que el nuevo régimen permanente es detectado para evitar los transitorios adicionales de establecimiento. La mayoría de las soluciones de SoA estiman la duración del transitorio, que puede provocar un transitorio adicional si la estimación no se ha hecho correctamente (por ejemplo, si la corriente de bobina del convertidor principal tiene un nivel superior o inferior al necesitado, el regulador lento del convertidor principal tiene que compensar esa diferencia una vez que el AEP es desactivado). Otras soluciones de SoA observan las variables de estado, asegurando que el sistema llegue al nuevo régimen permanente, o pueden ser informadas por la carga. 4. Durante el transitorio, como mínimo un subsistema, o bien el convertidor principal o el AEP, debería operar en el lazo cerrado. Implementando un sistema en el lazo cerrado, preferiblemente el subsistema AEP por su ancho de banda elevado, se incrementa la robustez del sistema a los parásitos. Además, el AEP puede operar con cualquier tipo de corriente de carga. Las soluciones que funcionan en el lazo abierto suelen preformar el control de balance de carga con mínimo tiempo, así reducen la duración del transitorio y tienen un impacto menor a las pérdidas del sistema. Por otro lado, esas soluciones demuestran una alta sensibilidad a las tolerancias y parásitos de los componentes. 5. El AEP debería inyectar la corriente a la salida en una manera controlada, así se reduce el riesgo de unas corrientes elevadas y potencialmente peligrosas y se incrementa la robustez del sistema bajo las perturbaciones de la tensión de entrada. Ese problema suele ser relacionado con los sistemas donde el AEP es implementado como un convertidor auxiliar. El convertidor auxiliar es diseñado para una potencia baja, con lo cual, los dispositivos elegidos son de baja corriente/potencia. Si la corriente no es controlada, bajo un pico de tensión de entrada provocada por otro parte del sistema (por ejemplo, otro convertidor conectado al mismo bus), se puede llegar a un pico en la corriente auxiliar que puede causar la perturbación de tensión de salida e incluso el fallo de los dispositivos del convertidor auxiliar. Sin embargo, cuando la corriente es controlada, usando control del pico de corriente o control con histéresis, la corriente auxiliar tiene el control con prealimentación (feed-forward) de tensión de entrada y la corriente es definida y limitada. Por otro lado, si la solución utiliza el control de balance de carga, el sistema puede actuar de forma deficiente si la tensión de entrada tiene un valor diferente del nominal, provocando que el AEP inyecta/toma más/menos carga que necesitada. 6. Escalabilidad del sistema a convertidores multifase. Como ya ha sido comentado anteriormente, para las aplicaciones VRM por la corriente de carga elevada, el convertidor principal suele ser implementado como multifase para distribuir las perdidas entre las fases y bajar el estrés térmico de los dispositivos. Para asegurar el reparto de las corrientes, normalmente un control de modo corriente es usado. Las soluciones de SoA que usan VMC son limitadas a la implementación con solo una fase. Esta tesis propone un nuevo método de control del flujo de energía por el AEP y el convertidor principal. El concepto propuesto se basa en la inyección controlada de la corriente auxiliar al nodo de salida donde la amplitud de la corriente es n-1 veces mayor que la corriente del condensador de salida con las direcciones apropiadas. De esta manera, el AEP genera un condensador virtual cuya capacidad es n veces mayor que el condensador físico y reduce la impedancia de salida. Como el concepto propuesto reduce la impedancia de salida usando el AEP, el concepto es llamado Output Impedance Correction Circuit (OICC) concept. El concepto se desarrolla para un convertidor tipo reductor síncrono multifase con control modo de corriente CMC (incluyendo e implementación con una fase) y puede operar con la tensión de salida constante o con AVP. Además, el concepto es extendido a un convertidor de una fase con control modo de tensión VMC. Durante la operación, el control de tensión de salida de convertidor principal y control de corriente del subsistema OICC están siempre cerrados, incrementando la robustez a las tolerancias de componentes y a los parásitos del cirquito y permitiendo que el sistema se pueda enfrentar a cualquier tipo de la corriente de carga. Según el método de control propuesto, el sistema se puede encontrar en dos estados: durante el régimen permanente, el sistema se encuentra en el estado Idle y el subsistema OICC esta desactivado. Por otro lado, durante el transitorio, el sistema se encuentra en estado Activo y el subsistema OICC está activado para reducir la impedancia de salida. El cambio entre los estados se hace de forma autónoma: el sistema entra en el estado Activo observando la corriente de condensador de salida y vuelve al estado Idle cunado el nuevo régimen permanente es detectado, observando las variables del estado. La validación del concepto OICC es hecha aplicándolo a un convertidor tipo reductor síncrono con dos fases y de 30W cuyo condensador de salida tiene capacidad de 140μF, mientras el factor de multiplicación n es 15, generando en el estado Activo el condensador virtual de 2.1mF. El subsistema OICC es implementado como un convertidor tipo reductor síncrono con PCMC. Comparando el funcionamiento del convertidor con y sin el OICC, los resultados demuestran que se ha logrado una reducción de la desviación de tensión de salida con factor 12, tanto con funcionamiento básico como con funcionamiento AVP. Además, los resultados son comparados con un prototipo de referencia que tiene la misma etapa de potencia y un condensador de salida físico de 2.1mF. Los resultados demuestran que los dos sistemas tienen el mismo comportamiento dinámico. Más aun, se ha cuantificado el impacto en las pérdidas del sistema operando bajo una corriente de carga pulsante y bajo DVS. Se demuestra que el sistema con OICC mejora el rendimiento del sistema, considerando las pérdidas cuando el sistema trabaja con la carga pulsante y con DVS. Por lo último, el condensador de salida de sistema con OICC es mucho más pequeño que el condensador de salida del convertidor de referencia, con lo cual, por usar el concepto OICC, la densidad de energía se incrementa. En resumen, las contribuciones principales de la tesis son: • El concepto propuesto de Output Impedance Correction Circuit (OICC), • El control a nivel de sistema basado en el método usado para cambiar los estados de operación, • La implementación del subsistema OICC en lazo cerrado conjunto con la implementación del convertidor principal, • La cuantificación de las perdidas dinámicas bajo la carga pulsante y bajo la operación DVS, y • La robustez del sistema bajo la variación del condensador de salida y bajo los escalones de carga consecutiva. ABSTRACT Development of new technologies allows engineers to push the performance of the integrated circuits to its limits. New generations of processors, DSPs or FPGAs are able to process information with high speed and high consumption or to wait in low power mode with minimum possible consumption. This huge variation in power consumption and the short time needed to change from one level to another, affect the specifications of the Voltage Regulated Module (VRM) that supplies the IC. Furthermore, additional mandatory features, such as Adaptive Voltage Positioning (AVP) and Dynamic Voltage Scaling (DVS), impose opposite trends on the design of the VRM power stage. In order to cope with high load-step amplitudes, the output capacitor of the VRM power stage output filter is drastically oversized, penalizing power density and the efficiency during the DVS operation. Therefore, the ongoing research trend is directed to improve the dynamic response of the VRM while reducing the size of the output capacitor. The output capacitor reduction leads to a smaller cost and longer life-time of the system since the big bulk capacitors, usually implemented with OSCON capacitors, may not be needed to achieve the desired dynamic behavior. An additional advantage is that, by reducing the output capacitance, dynamic voltage scaling (DVS) can be performed faster and with smaller stress on the power stage, since the needed amount of charge to change the output voltage is smaller. The dynamic behavior of the system with a linear control (Voltage mode control, VMC, Peak Current Mode Control, PCMC,…) is limited by the converter switching frequency and filter size. The reduction of the output capacitor can be achieved by increasing the switching frequency of the converter, thus increasing the bandwidth of the system, and/or by applying advanced non-linear controls. Applying nonlinear control, the system variables get saturated in order to reach the new steady-state in a minimum time, thus the output filter, more specifically the output inductor current slew-rate, determines the output voltage response. Therefore, by reducing the output inductor value, the inductor current reaches faster the new steady state, so a smaller amount of charge is taken from the output capacitor during the transient. The drawback of this approach is that the system efficiency is penalized due to increased switching losses and RMS currents. In order to achieve both the output capacitor reduction and high system efficiency, while satisfying strict dynamic specifications, a Multiphase converter system is adopted as a standard for VRM applications. In order to ensure the current sharing among the phases, the multiphase converter is usually implemented with current mode control. In order to overcome the limitation imposed by the output filter, the second possibility to reduce the output capacitor is to apply Topologic modifications of the basic power stage topology in order to increase the slew-rate of the inductor current and, therefore, reduce the transient duration. Since the transient is reduced, smaller amount of charge is taken from the output capacitor under the same load current, thus, the output capacitor can be reduced to achieve the same output voltage deviation. The third possibility to reduce the output capacitor of the converter is to introduce an additional energy path (AEP) to compensate the charge unbalance of the output capacitor, consequently reducing the transient time and output voltage deviation. Doing so, during the steady-state operation the system has high efficiency because the main low-bandwidth converter is designed to operate at moderate switching frequency, to meet the static requirements, whereas the dynamic behavior during the transients is determined by the high-bandwidth auxiliary energy path. The auxiliary energy path can be implemented as a resistive path, as a Linear regulator, LR, or as a switching converter. The first two implementations provide higher bandwidth, at the expense of increasing losses during the transient. On the other hand, the switching converter implementation presents lower bandwidth, limited by the auxiliary converter switching frequency, though it produces smaller losses compared to the two previous implementations. Depending on the application, the implementation and the control strategy of the system, there is a variety of proposed solutions in the State-of-the-Art (SoA), having different features where one solution offers some advantages over the others, but also some disadvantages. In general, an ideal additional energy path system should have the following features: 1. The impact on the system losses should be minimal. During its operation, the AEP generates additional losses, thus ideally, the AEP should operate for a short period of time, only when the transient is occurring; the other option is to have the AEP constantly on, but due to the inductor current ripple compensation at the output, unnecessary losses are generated. 2. The AEP should be activated nearly instantaneously to prevent bigger output voltage deviation. To achieve near instantaneous activation, the converter system can be informed by the load prior to the load-step or the system can observe the output capacitor current, which is the first system state variable that reacts on the load current perturbation. In this manner, the AEP is turned on with near zero output voltage error, providing smaller output voltage deviation. 3. The AEP should be deactivated once the new steady state is reached to avoid additional settling transients. Most of the SoA solutions estimate duration of the transient which may cause additional transient if the estimation is not performed correctly (e.g. if the main converter inductor current has higher or lower value than needed, the slow regulator of the main converter needs to compensate the difference after the AEP is deactivated). Other SoA solutions are observing state variables, ensuring that the system reaches the new steady state or they are informed by the load. 4. During the transient, at least one subsystem, either the main converter or the AEP, should be in closed-loop. Implementing a closed loop system, preferably the AEP subsystem, due its higher bandwidth, increases the robustness under system tolerances and circuit parasitic. In addition, the AEP can operate with any type of load. The solutions that operate in open loop usually perform minimum time charge balance control, thus reducing the transient length and minimizing the impact on the losses, however they are very sensitive to tolerances and parasitics. 5. The AEP should inject current at the output in a controlled manner, thus reducing the risk of high and potentially damaging currents and increasing robustness on the input voltage deviation. This issue is mainly related to the systems where AEP is implemented as auxiliary converter. The auxiliary converter is designed for small power and, as such, the MOSFETs are rated for small power/currents. If the current is not controlled, due to the some unpredicted spike in input voltage caused by some other part of the system (e.g. different converter), it may lead to a current spike in auxiliary current which will cause the perturbation of the output voltage and even failure of the switching components of auxiliary converter. In the case when the current is controlled, using peak CMC or Hysteretic Window CMC, the auxiliary converter has inherent feed-forwarding of the input voltage in current control and the current is defined and limited. Furthermore, if the solution employs charge balance control, the system may perform poorly if the input voltage has different value than the nominal, causing that AEP injects/extracts more/less charge than needed. 6. Scalability of the system to multiphase converters. As commented previously, in VRM applications, due to the high load currents, the main converters are implemented as multiphase to redistribute losses among the modules, lowering temperature stress of the components. To ensure the current sharing, usually a Current Mode Control (CMC) is employed. The SoA solutions that are implemented with VMC are limited to a single stage implementation. This thesis proposes a novel control method of the energy flow through the AEP and the main converter system. The proposed concept relays on a controlled injection of the auxiliary current at the output node where the instantaneous current value is n-1 times bigger than the output capacitor current with appropriate directions. Doing so, the AEP creates an equivalent n times bigger virtual capacitor at the output, thus reducing the output impedance. Due to the fact that the proposed concept reduces the output impedance using the AEP, it has been named the Output Impedance Correction Circuit (OICC) concept. The concept is developed for a multiphase CMC synchronous buck converter (including a single phase implementation), operating with a constant output voltage and with AVP feature. Further, it is extended to a single phase VMC synchronous buck converter. During the operation, the main converter voltage loop and the OICC subsystem capacitor current loop is constantly closed, increasing the robustness under system tolerances and circuit parasitic and allowing the system to operate with any load-current shape or pattern. According to the proposed control method, the system operates in two states: during the steady-state the system is in the Idle state and the OICC subsystem is deactivated, while during the load-step transient the system is in the Active state and the OICC subsystem is activated in order to reduce the output impedance. The state changes are performed autonomously: the system enters in the Active state by observing the output capacitor current and it returns back to the Idle state when the steady-state operation is detected by observing the state variables. The validation of the OICC concept has been done by applying it to a 30W two phase synchronous buck converter with 140μF output capacitor and with the multiplication factor n equal to 15, generating during the Active state equivalent output capacitor of 2.1mF. The OICC subsystem is implemented as single phase PCMC synchronous buck converter. Comparing the converter operation with and without the OICC the results demonstrate that the 12 times reduction of the output voltage deviation is achieved, for both basic operation and for the AVP operation. Furthermore, the results have been compared to a reference prototype which has the same power stage and a fiscal output capacitor of 2.1mF. The results show that the two systems have the same dynamic behavior. Moreover, an impact on the system losses under the pulsating load and DVS operation has been quantified and it has been demonstrated that the OICC system has improved the system efficiency, considering the losses when the system operates with the pulsating load and the DVS operation. Lastly, the output capacitor of the OICC system is much smaller than the reference design output capacitor, therefore, by applying the OICC concept the power density can be increased. In summary, the main contributions of the thesis are: • The proposed Output Impedance Correction Circuit (OICC) concept, • The system level control based on the used approach to change the states of operation, • The OICC subsystem closed-loop implementation, together with the main converter implementation, • The dynamic losses under the pulsating load and the DVS operation quantification, and • The system robustness on the capacitor impedance variation and consecutive load-steps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phaseolus vulgaris L. (frijol común o judía) es una leguminosa de gran demanda para la nutrición humana y un producto agrícola muy importante. Sin embargo, la producción de frijol se ve limitada por presiones ambientales como la sequía. En México, el 85% de la cosecha de frijol se produce en la temporada de primavera-verano, principalmente en las regiones del altiplano semiárido con una precipitación anual entre 250 y 400 mm. A pesar del implemento de tecnología en el campo, los factores naturales impiden al agricultor llegar a los rendimientos deseados. El Instituto Nacional de Investigaciones Forestales, Agrícolas y Pecuarias (INIFAP), como instituto de investigación gubernamental en México, tiene como objetivo la mejora de cultivos estratégicos, uno de ellos, P. vulgaris. Los estudios en relación a la sequía se enfocan especialmente en la selección de genotipos tolerantes, los cuales son sometidos en condiciones de estrés y monitoreando parámetros como el rendimiento y peso de semilla, además de algunos indicadores tales como índice de cosecha. El resultado de estos trabajos ha sido la obtención de variedades con mayor tolerancia a la sequía, tales como Pinto Villa y Pinto Saltillo. En los últimos años se ha avanzado notablemente en el conocimiento de las bases moleculares en las respuestas de las plantas al estrés. De acuerdo a diversos estudios se ha demostrado que las plantas bajo estrés por sequía experimentan cambios en la expresión de genes involucrados en la señalización, regulación de la transcripción y la traducción, transporte de agua y la función directa en la protección celular. También se ha observado que el déficit de agua es causado por las temperaturas extremas y la alta concentración de sales, por lo que al nivel molecular, las respuestas al estrés tienen puntos de especificidad y puntos de entrecruzamiento. La sequía puede generar estreses secundarios, tales como el nutricional, oxidativo y osmótico. Sin embargo, es necesario identificar y caracterizar muchos de los componentes involucrados en las respuestas al déficit hídrico, la caracterización de estos genes permitirá tener una mejor comprensión de los mecanismos bioquímicos y fisiológicos involucrados en la tolerancia al estrés. Actualmente, con el apoyo de la biología molecular se han identificado algunos genes que otorgan ventajas para la adaptación a ambientes desfavorables. Por lo que el objetivo del presente trabajo es identificar marcadores genéticos asociados a rasgos fenotípicos con énfasis a la tolerancia a estrés hídrico en P. vulgaris. Una vez establecidos los marcadores asociados al estrés hídrico, es factible considerar su uso para la selección asistida por marcadores en líneas o variedades de frijol de interés para los mejoradores. Se evaluaron 282 familias F3:5 derivadas de la cruza entre los cultivares Pinto Villa y Pinto Saltillo. Las familias se sembraron bajo un diseño simple de látice 17x17, el experimento se llevo acabo en el ciclo primavera-verano del 2010 y 2011, y otoñoinvierno de 2010 en el Campo Experimental Bajío del INIFAP con dos repeticiones para cada tratamiento de humedad (riego completo y sequía terminal). En todos los genotipos se realizó el fenotipado (variables fenotípicas) y el genotipado a través de marcadores moleculares. Los análisis estadísticos se basaron en el análisis de componentes principales (Eigen Analysis Selection Index Method, ESIM), la asociación entre marcadores SNP y el fenotipado (paquete SNPassoc para R) y el análisis de varianza (ANOVA). Los valores ESIM mostraron que las variables de Rendimiento, Días a floración, Días a madurez fisiológica e Índice de cosecha fueron sobresalientes en sequía terminal, por lo que se sugieren tomarse en consideración para los estudios de sequía en P. vulgaris como monitores de evaluación a la resistencia. Se identificaron nueve familias sobresalieron por sus valores ESIM (PV/PS6, 22, 131, 137, 149, 154, 201, 236 y 273), además de presentar valores superiores para el rendimiento en comparación con los parentales. Estos genotipos son candidatos interesantes para realizar estudios de identificación de loci asociados con la respuesta al estrés, y como potenciales parentales en el desarrollo de nuevas variedades de frijol. En los análisis de asociación SNPassoc se identificaron 83 SNPs significativos (p<0,0003) asociados a los rasgos fenotípicos, obteniendo un total de 222 asociaciones, de las cuales predomina el modelo genético de codominancia para las variables Días a floración, Periodo reproductivo y Biomasa total. Treinta y siete SNPs se identificaron a diferentes funciones biológicas a través del análisis de anotación funcional, de los cuales 12 SNPs (9, 18, 28, 39, 61, 69, 80, 106, 115, 128, 136 y 142) sobresalen por su asociación al fenotipado, y cuya anotación funcional indica que se encuentran en genes relacionados a la tolerancia a la sequía, tales como la actividad kinasa, actividad metabólica del almidón, carbohidratos y prolina, respuesta al estrés oxidativo, así como en los genes LEA y posibles factores de transcripción. En el caso de los análisis ANOVA, se identificaron 72 asociaciones entre los SNPs y las variables fenotípicas (F< 3,94E-04). Las 72 asociaciones corresponden a 30 SNPs y 7 variables fenotípicas, de las que predomina Peso de 100 semillas y Periodo reproductivo. Para los rasgos de Rendimiento, Índice de cosecha y Días a madurez fisiológica se presentaron asociaciones con seis SNPs (17, 34, 37, 50, 93 y 107), de los cuales, a los SNP37 y SNP107 fueron identificados a la anotación biológica de protein binding. Por otro lado, los SNP106 y SNP128 asociados al Periodo reproductivo, son genes con actividad kinasa y actividad metabólica del almidón, respectivamente. Para los marcadores tipo AFLP, se identificaron 271 asociaciones (F<2,34E-04). Las asociaciones corresponden a 86 AFLPs con todas las variables fenotípicas evaluadas, de las que predomina peso de 100 semillas, Días a floración y Periodo reproductivo. Debido a que los en los AFLPs no es posible determinar su anotación biológica, se proponen como marcadores potenciales relacionados a la resistencia a la sequía en frijol. Los AFLPs candidatos requieren más estudios tales como la secuenciación de los alelos respectivos, así como la identificación de éstas secuencias en el genoma de referencia y su anotación biológica, entre otros análisis, de esta manera podríamos establecer aquellos marcadores candidatos a la validación para la selección asistida. El presente trabajo propone tanto genotipos como marcadores genéticos, que deben ser validados para ser utilizados en el programa de mejoramiento de P. vulgaris, con el objetivo de desarrollar nuevas líneas o variedades tolerantes a la sequía. ABSTRACT Phaseolus vulgaris L. (common bean or judia) is a legume of great demand for human consumption and an important agricultural product. However, the common bean production is limited by environmental stresses, such as drought. In Mexico, 85% of the common bean crop is produced in the spring-summer season mainly in semiarid highland regions with a rainfall between 250 and 400 mm per year. In spite of the improvement of crop technology, the natural factors hamper getting an optimal yield. The National Institute for Forestry, Agriculture and Livestock (INIFAP) is a government research institute from Mexico, whose main objective is the genetic breeding of strategic crops, like P. vulgaris L. The drought tolerance studies particularly focus on the selection of bean tolerant genotypes, which are subjected to stress conditions, by means of monitoring parameters such as yield and seed weight, plus some agronomic indicators such as harvest index. The results of these works have led to obtain cultivars with higher drought tolerance such as Pinto Villa and Pinto Saltillo. Significant achievements have been recently made in understanding the molecular basis of stress plant responses. Several studies have shown that plants under drought stress present changes in gene expression related to cell signalling, transcriptional and translational regulation, water transport and cell protection. In addition, it has been observed that the extreme temperatures and high salt concentrations can cause a water deficiency so, at the molecular level, stress responses have specific and crossover points. The drought can cause secondary stresses, such as nutritional, oxidative and osmotic stress. It is required the identification of more components involved in the response to water deficit, the characterization of these genes will allow a better understanding of the biochemical and physiological mechanisms involved in stress tolerance. Currently, with the support of molecular biology techniques, some genes that confer an advantage for the crop adaptation to unfavourable environments have been identified. The objective of this study is to identify genetic markers associated with phenotypic traits with emphasis on water stress tolerance in P. vulgaris. The establishment of molecular markers linked to drought tolerance would make possible their use for marker-assisted selection in bean breeding programs. Two hundred and eighty two F3:5 families derived from a cross between the drought resistant cultivars Pinto Villa and Pinto Saltillo were evaluated. The families were sowed under a 17x17 simple lattice design. The experiment was conducted between spring-summer seasons in 2010 and 2011, and autumn-winter seasons in 2010 at the Bajio Experimental Station of INIFAP with two treatments (full irrigation and terminal drought). All families were phenotyped and genotyped using molecular markers. Statistical analysis was based on principal component analysis (Eigen Analysis Selection Index Method, ESIM), association analysis between SNP markers and phenotype (SNPassoc package R) and analysis of variance (ANOVA). The ESIM values showed that seed yield, days to flowering, days to physiological maturity and harvest index were outstanding traits in terminal drought treatment, so they could be considered as suitable parameters for drought-tolerance evaluation in P. vulgaris. Nine outstanding families for the ESIM values were identified (PV/PS6, 22, 131, 137, 149, 154, 201, 236 and 273), in addition, these families showed higher values for seed yield compared to the parental cultivars. These families are promising candidates for studies focused on the identification of loci associated to the stress response, and as potential parental cultivars for the development of new varieties of common bean. In the SNPassoc analysis, 83 SNPs were found significantly associated (p<0.0003) with phenotypic traits, obtaining a total of 222 associations, most of which involved the traits days to flowering, reproductive period and total biomass under a codominant genetic model. The functional annotation analysis showed 37 SNPs with different biological functions, 12 of them (9, 18, 28, 39, 61, 69, 80, 106, 115, 128, 136 and 142) stand out by their association to phenotype. The functional annotation suggested a connection with genes related to drought tolerance, such as kinase activity, starch, carbohydrates and proline metabolic processes, responses to oxidative stress, as well as LEA genes and putative transcription factors. In the ANOVA analysis, 72 associations between SNPs and phenotypic traits (F<3.94E- 04) were identified. All of these associations corresponded to 30 SNPs markers and seven phenotypic traits. Weight of 100 seeds and reproductive period were the traits with more associations. Seed yield, harvest index and days to physiological maturity were associated to six SNPs (17, 34, 37, 50, 93 and 107), the SNP37 and SNP107 were identified as located in protein binding genes. The SNP106 and SNP128 were associated with the reproductive period and belonged to genes with kinase activity and genes related to starch metabolic process, respectively. In the case of AFLP markers, 271 associations (F<2.34E-04) were identified. The associations involved 86 AFLPs and all phenotypic traits, being the most frequently associated weight of 100 seeds, days to flowering and reproductive period. Even though it is not possible to perform a functional annotation for AFLP markers, they are proposed as potential markers related to drought resistance in common bean. AFLPs candidates require additional studies such as the sequencing of the respective alleles, identification of these sequences in the reference genome and gene annotation, before their use in marker assisted selection. This work, although requires further validation, proposes both genotypes and genetic markers that could be used in breeding programs of P. vulgaris in order to develop new lines or cultivars with enhanced drought-tolerance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los Centros de Datos se encuentran actualmente en cualquier sector de la economía mundial. Están compuestos por miles de servidores, dando servicio a los usuarios de forma global, las 24 horas del día y los 365 días del año. Durante los últimos años, las aplicaciones del ámbito de la e-Ciencia, como la e-Salud o las Ciudades Inteligentes han experimentado un desarrollo muy significativo. La necesidad de manejar de forma eficiente las necesidades de cómputo de aplicaciones de nueva generación, junto con la creciente demanda de recursos en aplicaciones tradicionales, han facilitado el rápido crecimiento y la proliferación de los Centros de Datos. El principal inconveniente de este aumento de capacidad ha sido el rápido y dramático incremento del consumo energético de estas infraestructuras. En 2010, la factura eléctrica de los Centros de Datos representaba el 1.3% del consumo eléctrico mundial. Sólo en el año 2012, el consumo de potencia de los Centros de Datos creció un 63%, alcanzando los 38GW. En 2013 se estimó un crecimiento de otro 17%, hasta llegar a los 43GW. Además, los Centros de Datos son responsables de más del 2% del total de emisiones de dióxido de carbono a la atmósfera. Esta tesis doctoral se enfrenta al problema energético proponiendo técnicas proactivas y reactivas conscientes de la temperatura y de la energía, que contribuyen a tener Centros de Datos más eficientes. Este trabajo desarrolla modelos de energía y utiliza el conocimiento sobre la demanda energética de la carga de trabajo a ejecutar y de los recursos de computación y refrigeración del Centro de Datos para optimizar el consumo. Además, los Centros de Datos son considerados como un elemento crucial dentro del marco de la aplicación ejecutada, optimizando no sólo el consumo del Centro de Datos sino el consumo energético global de la aplicación. Los principales componentes del consumo en los Centros de Datos son la potencia de computación utilizada por los equipos de IT, y la refrigeración necesaria para mantener los servidores dentro de un rango de temperatura de trabajo que asegure su correcto funcionamiento. Debido a la relación cúbica entre la velocidad de los ventiladores y el consumo de los mismos, las soluciones basadas en el sobre-aprovisionamiento de aire frío al servidor generalmente tienen como resultado ineficiencias energéticas. Por otro lado, temperaturas más elevadas en el procesador llevan a un consumo de fugas mayor, debido a la relación exponencial del consumo de fugas con la temperatura. Además, las características de la carga de trabajo y las políticas de asignación de recursos tienen un impacto importante en los balances entre corriente de fugas y consumo de refrigeración. La primera gran contribución de este trabajo es el desarrollo de modelos de potencia y temperatura que permiten describes estos balances entre corriente de fugas y refrigeración; así como la propuesta de estrategias para minimizar el consumo del servidor por medio de la asignación conjunta de refrigeración y carga desde una perspectiva multivariable. Cuando escalamos a nivel del Centro de Datos, observamos un comportamiento similar en términos del balance entre corrientes de fugas y refrigeración. Conforme aumenta la temperatura de la sala, mejora la eficiencia de la refrigeración. Sin embargo, este incremente de la temperatura de sala provoca un aumento en la temperatura de la CPU y, por tanto, también del consumo de fugas. Además, la dinámica de la sala tiene un comportamiento muy desigual, no equilibrado, debido a la asignación de carga y a la heterogeneidad en el equipamiento de IT. La segunda contribución de esta tesis es la propuesta de técnicas de asigación conscientes de la temperatura y heterogeneidad que permiten optimizar conjuntamente la asignación de tareas y refrigeración a los servidores. Estas estrategias necesitan estar respaldadas por modelos flexibles, que puedan trabajar en tiempo real, para describir el sistema desde un nivel de abstracción alto. Dentro del ámbito de las aplicaciones de nueva generación, las decisiones tomadas en el nivel de aplicación pueden tener un impacto dramático en el consumo energético de niveles de abstracción menores, como por ejemplo, en el Centro de Datos. Es importante considerar las relaciones entre todos los agentes computacionales implicados en el problema, de forma que puedan cooperar para conseguir el objetivo común de reducir el coste energético global del sistema. La tercera contribución de esta tesis es el desarrollo de optimizaciones energéticas para la aplicación global por medio de la evaluación de los costes de ejecutar parte del procesado necesario en otros niveles de abstracción, que van desde los nodos hasta el Centro de Datos, por medio de técnicas de balanceo de carga. Como resumen, el trabajo presentado en esta tesis lleva a cabo contribuciones en el modelado y optimización consciente del consumo por fugas y la refrigeración de servidores; el modelado de los Centros de Datos y el desarrollo de políticas de asignación conscientes de la heterogeneidad; y desarrolla mecanismos para la optimización energética de aplicaciones de nueva generación desde varios niveles de abstracción. ABSTRACT Data centers are easily found in every sector of the worldwide economy. They consist of tens of thousands of servers, serving millions of users globally and 24-7. In the last years, e-Science applications such e-Health or Smart Cities have experienced a significant development. The need to deal efficiently with the computational needs of next-generation applications together with the increasing demand for higher resources in traditional applications has facilitated the rapid proliferation and growing of data centers. A drawback to this capacity growth has been the rapid increase of the energy consumption of these facilities. In 2010, data center electricity represented 1.3% of all the electricity use in the world. In year 2012 alone, global data center power demand grew 63% to 38GW. A further rise of 17% to 43GW was estimated in 2013. Moreover, data centers are responsible for more than 2% of total carbon dioxide emissions. This PhD Thesis addresses the energy challenge by proposing proactive and reactive thermal and energy-aware optimization techniques that contribute to place data centers on a more scalable curve. This work develops energy models and uses the knowledge about the energy demand of the workload to be executed and the computational and cooling resources available at data center to optimize energy consumption. Moreover, data centers are considered as a crucial element within their application framework, optimizing not only the energy consumption of the facility, but the global energy consumption of the application. The main contributors to the energy consumption in a data center are the computing power drawn by IT equipment and the cooling power needed to keep the servers within a certain temperature range that ensures safe operation. Because of the cubic relation of fan power with fan speed, solutions based on over-provisioning cold air into the server usually lead to inefficiencies. On the other hand, higher chip temperatures lead to higher leakage power because of the exponential dependence of leakage on temperature. Moreover, workload characteristics as well as allocation policies also have an important impact on the leakage-cooling tradeoffs. The first key contribution of this work is the development of power and temperature models that accurately describe the leakage-cooling tradeoffs at the server level, and the proposal of strategies to minimize server energy via joint cooling and workload management from a multivariate perspective. When scaling to the data center level, a similar behavior in terms of leakage-temperature tradeoffs can be observed. As room temperature raises, the efficiency of data room cooling units improves. However, as we increase room temperature, CPU temperature raises and so does leakage power. Moreover, the thermal dynamics of a data room exhibit unbalanced patterns due to both the workload allocation and the heterogeneity of computing equipment. The second main contribution is the proposal of thermal- and heterogeneity-aware workload management techniques that jointly optimize the allocation of computation and cooling to servers. These strategies need to be backed up by flexible room level models, able to work on runtime, that describe the system from a high level perspective. Within the framework of next-generation applications, decisions taken at this scope can have a dramatical impact on the energy consumption of lower abstraction levels, i.e. the data center facility. It is important to consider the relationships between all the computational agents involved in the problem, so that they can cooperate to achieve the common goal of reducing energy in the overall system. The third main contribution is the energy optimization of the overall application by evaluating the energy costs of performing part of the processing in any of the different abstraction layers, from the node to the data center, via workload management and off-loading techniques. In summary, the work presented in this PhD Thesis, makes contributions on leakage and cooling aware server modeling and optimization, data center thermal modeling and heterogeneityaware data center resource allocation, and develops mechanisms for the energy optimization for next-generation applications from a multi-layer perspective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bismuth ultra-thin films grown on n-GaAs electrodes via electrodeposition are porous due to a blockade of the electrode surface caused by adsorbed hydrogen when using acidic electrolytes. In this study, we discuss the existence of two sources of hydrogen adsorption and we propose different routes to unblock the n-GaAs surface in order to improve Bi films compactness. Firstly, we demonstrate that increasing the electrolyte temperature provides compact yet polycrystalline Bi films. Cyclic voltammetry scans indicate that this low crystal quality might be a result of the incorporation of Bi hydroxides within the Bi film as a result of the temperature increase. Secondly, we have illuminated the semiconductor surface to take advantage of photogenerated holes. These photocarriers oxidize the adsorbed hydrogen unblocking the surface, but also create pits at the substrate surface that degrade the Bi/GaAs interface and prevent an epitaxial growth. Finally, we show that performing a cyclic voltammetry scan before electrodeposition enables the growth of compact Bi ultra-thin films of high crystallinity on semiconductor substrates with a doping level low enough to perform transport measurements.