63 resultados para Nonlinear Dynamic Response


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this paper is to analyse the influence of the variation of some parameters used in the analysis of the dynamic response of offshore structures under the action of wind generated waves. The structural response has been obtained by stochastic methods using two discretization models. One with lumped parameters, using translational degrees of freedom (d.o.f.) and the other with one-dimensional finite elements. Using each of these methods the problem has been solved with several d.o.f., analysing the influence of the number of d.o.f. on the results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a time-domain stochastic system identification method based on maximum likelihood estimation (MLE) with the expectation maximization (EM) algorithm. The effectiveness of this structural identification method is evaluated through numerical simulation in the context of the ASCE benchmark problem on structural health monitoring. The benchmark structure is a four-story, two-bay by two-bay steel-frame scale model structure built in the Earthquake Engineering Research Laboratory at the University of British Columbia, Canada. This paper focuses on Phase I of the analytical benchmark studies. A MATLAB-based finite element analysis code obtained from the IASC-ASCE SHM Task Group web site is used to calculate the dynamic response of the prototype structure. A number of 100 simulations have been made using this MATLAB-based finite element analysis code in order to evaluate the proposed identification method. There are several techniques to realize system identification. In this work, stochastic subspace identification (SSI)method has been used for comparison. SSI identification method is a well known method and computes accurate estimates of the modal parameters. The principles of the SSI identification method has been introduced in the paper and next the proposed MLE with EM algorithm has been explained in detail. The advantages of the proposed structural identification method can be summarized as follows: (i) the method is based on maximum likelihood, that implies minimum variance estimates; (ii) EM is a computational simpler estimation procedure than other optimization algorithms; (iii) estimate more parameters than SSI, and these estimates are accurate. On the contrary, the main disadvantages of the method are: (i) EM algorithm is an iterative procedure and it consumes time until convergence is reached; and (ii) this method needs starting values for the parameters. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the benchmark structure have been estimated using both the SSI method and the proposed MLE + EM method. The numerical results show that the proposed method identifies eigenfrequencies, damping ratios and mode shapes reasonably well even in the presence of 10% measurement noises. These modal parameters are more accurate than the SSI estimated modal parameters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A large number of reinforced concrete (RC) frame structures built in earthquake-prone areas such as Haiti are vulnerable to strong ground motions. Structures in developing countries need low-cost seismic retrofit solutions to reduce their vulnerability. This paper investigates the feasibility of using masonry infill walls to reduce deformations and damage caused by strong ground motions in brittle and weak RC frames designed only for gravity loads. A numerical experiment was conducted in which several idealized prototypes representing RC frame structures of school buildings damaged during the Port-au-Prince earthquake (Haiti, 2010) were strengthened by adding elements representing masonry infill walls arranged in different configurations. Each configuration was characterized by the ratio Rm of the area of walls in the direction of the ground motion (in plan) installed in each story to the total floor area. The numerical representations of these idealized RC frame structures with different values of Rm were (hypothetically) subjected to three major earthquakes with peak ground accelerations of approximately 0.5g. The results of the non-linear dynamic response analyses were summarized in tentative relationships between Rm and four parameters commonly used to characterize the seismic response of structures: interstory drift, Park and Ang indexes of damage, and total amount of energy dissipated by the main frame. It was found that Rm=4% is a reasonable minimum design value for seismic retrofitting purposes in cases in which available resources are not sufficient to afford conventional retrofit measures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper addresses the seismic analysis of a deeply embedded non-slender structure hosting the pumping unit of a reservoir. The dynamic response in this type of problems is usually studied under the assumption of a perfectly rigid structure using a sub-structuring procedure (three-step solution) proposed specifically for this hypothesis. Such an approach enables a relatively simple assessment of the importance of some key factors influencing the structural response. In this work, the problem is also solved in a single step using a direct approach in which the structure and surrounding soil are modelled as a coupled system with its actual geometry and flexibility. Results indicate that, quite surprisingly, there are significant differences among prediction using both methods. Furthermore, neglecting the flexibility of the structure leads to a significant underestimation of the spectral accelerations at certain points of the structure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En este proyecto se van a aplicar las técnicas de análisis de ruido para caracterizar la respuesta dinámica de varios sensores de temperatura, tanto termorresistencias de platino como de termopares. Estos sensores son imprescindibles para él correcto funcionamiento de las centrales nucleares y requieren vigilancia para garantizar la exactitud de las medidas. Las técnicas de análisis de ruido son técnicas pasivas, es decir, no afectan a la operación de la planta y permiten realizar una vigilancia in situ de los sensores. Para el caso de los sensores de temperatura, dado que se pueden asimilar a sistemas de primer orden, el parámetro fundamental a vigilar es el tiempo de respuesta. Éste puede obtenerse para cada una de las sondas por medio de técnicas en el dominio de la frecuencia (análisis espectral) o por medio de técnicas en el dominio del tiempo (modelos autorregresivos). Además de la estimación del tiempo de respuesta, se realizará una caracterización estadística de las sondas. El objetivo es conocer el comportamiento de los sensores y vigilarlos de manera que se puedan diagnosticar las averías aunque éstas estén en una etapa incipiente. ABSTRACT In this project we use noise analysis technique to study the dynamic response of RTDs (Resistant temperature detectors) and thermocouples. These sensors are essential for the proper functioning of nuclear power plants and therefore need to be monitored to guarantee accurate measurements. The noise analysis techniques do not affect plant operation and allow in situ monitoring of the sensors. Temperature sensors are equivalent to first order systems. In these systems the main parameter to monitor is the response time which can be obtained by means of techniques in the frequency domain (spectral analysis) as well as time domain (autoregressive models). Besides response time estimation the project will also include a statistical study of the probes. The goal is to understand the behavior of the sensors and monitor them in order to detect any anomalies or malfunctions even if they occur in an early stage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a methodology is proposed to find the dynamics poles of a capacitive pressure transmitter in order to enhance and extend the on line surveillance of this type of sensors based on the response time measurement by applying noise analysis techniques and the Dynamic Data System. Several measurements have been analyzed taken from a Pressurized Water Reactor. The methodology proposes an autoregressive fit whose order is determined by the sensor dynamics poles. Nevertheless, the signals that have been analyzed, could not be filtered properly in order to remove the plant noise, thus, this was considered as an additional pair of complex conjugate poles. With this methodology we have come up with the numerical value of the sensor second real pole in spite of its low influence on the sensor dynamic response. This opens up a more accurate on line sensor surveillance since the previous methods were achieved by considering one real pole only.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The combination of minimum time control and multiphase converter is a favorable option for dc-dc converters in applications where output voltage variation is required, such as RF amplifiers and dynamic voltage scaling in microprocessors, due to their advantage of fast dynamic response. In this paper, an improved minimum time control approach for multiphase buck converter that is based on charge balance technique, aiming at fast output voltage transition is presented. Compared with the traditional method, the proposed control takes into account the phase delay and current ripple in each phase. Therefore, by investigating the behavior of multiphase converter during voltage transition, it resolves the problem of current unbalance after the transient, which can lead to long settling time of the output voltage. The restriction of this control is that the output voltage that the converter can provide is related to the number of the phases, because only the duty cycles at which the multiphase converter has total ripple cancellation are used in this approach. The model of the proposed control is introduced, and the design constraints of the buck converters filter for this control are discussed. In order to prove the concept, a four-phase buck converter is implemented and the experimental results that validate the proposed control method are presented. The application of this control to RF envelope tracking is also presented in this paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A significant number of short-to-mid height RC buildings with wide beams have been constructed in areas of moderate seismicity of Spain, mainly for housing and administrative use. The buildings have a framed structure with one-way slabs; the wide beams constitute the distinctive characteristic, their depth being equal to that of the rest of the slab, thus providing a flat lower surface, convenient for construction and the layout of facilities. Seismic behavior in the direction of the wide beams appears to be deficient because of: (i) low lateral strength, mainly because of the small effective depth of the beams, (ii) inherent low ductility of the wide beams, generated by high amount of reinforcement, (iii) the big strut compressive forces developed inside the column-beam connections due to the low height of the beams, and (iv) the fact that the wide beams are wider than the columns, meaning that the contribution of the outer zones to the resistance of the beam-column joints is unreliable because there is no torsion reinforcement. In the orthogonal direction, the behavior is worse since the only members of the slabs that contribute to the lateral resistance are the joists and the façade beams. Moreover, these buildings were designed with codes that did not include ductility requirements and required only a low lateral resistance; indeed, in many cases, seismic action was not considered at all. Consequently, the seismic capacity of these structures is not reliable. The objective of this research is to assess numerically this capability, whereas further research will aim to propose retrofit strategies. The research approach consists of: (i) selecting a number of 3-story and 6-story buildings that represent the vast majority of the existing ones and (ii) evaluating their vulnerability through three types of analyses, namely: code-type, push-over and nonlinear dynamic analysis. Given the low lateral resistance of the main frames, the cooperation of the masonry infill walls is accounted for; for each representative building, three wall densities are considered. The results of the analyses show that the buildings in question exhibit inadequate seismic behavior in most of the examined situations. In general, the relative performance is less deficient for Target Drift CP (Collapse Prevention) than for IO (Immediate Occupancy). Since these buildings are selected to be representative of the vast majority of buildings with wide beams that were constructed in Spain without accounting for any seismic consideration, our conclusions can be extrapolated to a broader scenario.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work proposes design energy spectra in terms of an equivalent velocity, intended for regions with design peak acceleration 0.3 g or higher. These spectra were derived through linear and nonlinear dynamic analyses on a number of selected Turkish strong ground motion records. In the long and mid period ranges the analyses are linear, given the relative insensitivity of the spectra to structural parameters other than the fundamental period; conversely, in the short period range, the spectra are more sensitive to the structural parameters and, hence, nonlinear analyses are required. The selected records are classified in eight groups with respect to soil type (stiff or soft soil), the severity of the earthquake in terms of surface magnitude Ms(Ms≤ 5.5 and Ms> 5.5) and the relevance of the near-source effects (impulsive or vibratory). For each of these groups, median and characteristic spectra are proposed; such levels would respectively correspond to 50 and 95 % percentiles. These spectra have an initial linear growing branch in the short period range, a horizontal branch in the mid period range and a descending branch in the long period range. Empirical criteria for estimating the hysteretic energy from the input energy are suggested. The proposed design spectra are compared with those obtained from other studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The bandwidth achievable by using voltage mode control or current mode control in switch-mode power supply is limited by the switching frequency. Fast transient response requires high switching frequency, although lower switching frequencies could be more suitable for higher efficiency. This paper proposes the use of hysteretic control of the output capacitor $(C_{out})$ current to improve the dynamic response of the buck converter. An external voltage loop is required to accurately regulate the output voltage. The design of the hysteretic loop and the voltage loop are presented. Besides, it is presented a non-invasive current sensor that allows measuring the current in the capacitor. This strategy has been applied for DVS (dynamic voltage scaling) on a 5 MHz buck converter. Experimental results validate the proposed control technique and show fast transient response from 1.5 V to 2.5 V in 2 $mu{rm s}$.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several boost-derived topologies are analyzed and compared for an aerospace application that uses a 100 V voltage bus. All these topologies have been designed and optimized considering the electrical requirements and the reduced number of space-qualified components. The comparison evaluates the power losses, mass, and dynamic response. Special attention has been paid to those topologies that may cancel the inherent right half plane zero (RHP) zero of the boost topology. Experimental results of the less common topologies are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ripple-based controls can strongly reduce the required output capacitance in PowerSoC converter thanks to a very fast dynamic response. Unfortunately, these controls are prone to sub-harmonic oscillations and several parameters affect the stability of these systems. This paper derives and validates a simulation-based modeling and stability analysis of a closed-loop V 2Ic control applied to a 5 MHz Buck converter using discrete modeling and Floquet theory to predict stability. This allows the derivation of sensitivity analysis to design robust systems. The work is extended to different V 2 architectures using the same methodology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El presente proyecto desarrolla el diseño de un sistema de pitch pasivo para aerogeneradores en entornos urbanos en el marco del proyecto SWIP (Soluciones, componentes y herramientas novedosos e innovadores para la integración de la energía eólica en áreas urbanas y suburbanas) En primer lugar se describe el marco de trabajo así como una introducción teórica de energía eólica y de sistemas de pitch o de control de paso de pala. Aquí son presentados los fundamentos del accionamiento del pitch pasivo diseñado. A continuación se presenta el mecanismo diseñado y los cálculos sobre él efectuados para el ajuste de sus parámetros de funcionamiento. Posteriormente se plantea el análisis estructural de los distintos casos de carga a los que estará sometido y el estudio de su respuesta dinámica a perturbaciones reales con las que trabajará durante su funcionamiento normal. Por último, se aclaran otra serie de factores como la seguridad y el sobredimensionamiento del generador y se hace un análisis económico del diseño junto con una comparativa con las tecnologías alternativas existentes. ABSTRACT The present project develops the design of a passive pitch system for wind turbines for urban and sub-urban areas for the SWIP European Project (New innovative solutions, components and tools for the integration of wind energy in urban and peri-urban áreas) Firstly, the framework is described, as well as a theoretical introduction to wind energy and pitch systems. Here, the principles of the designed passive pitch mechanism are presented. Subsequently, the designed mechanism is presented together with the calculations on it for the adjustment of its working parameters. After that, the structural analyses for the different load cases that will affect the design are studied. Afterwards, the dynamic response of the system to real perturbations during its operation is studied. Finally, some concepts concerning security issues or oversizing of the electric generator are considered and an economic analysis is performed for the design and also to compare it with the alternative existing technologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El principal objetivo de este trabajo es aportar conocimiento para contestar la pregunta: ¿hasta que punto los ensayos en túnel aerodinámico pueden contribuir a determinar las características que afectan la respuesta dinámica de los aerogeneradores operando en terreno complejo?. Esta pregunta no es nueva, de hecho, el debate en la comunidad científica comenzó en el primer tercio del siglo pasado y aún está intensamente vivo. El método generalmente aceptado para enfrentar el mencionado problema consiste en analizar un caso de estudio determinado en el cual se aplican tanto ensayos a escala real como análisis computacionales y ensayos en túnel aerodinámico. Esto no es ni fácil ni barato. Esta es la razón por la cual desde el experimento de Askervein en 1988, los modelizadores del flujo atmosférico tuvieron que esperar hasta 2007 a que el experimento de Bolund fuese puesto en marcha con un despliegue de medios técnicos equivalentes (teniendo en cuenta la evolución de las tecnologías de sensores y computación). El problema contempla tantos aspectos que ambas experiencias fueron restringidas a condiciones de atmósfera neutra con efectos de Coriolis despreciables con objeto de reducir la complejidad. Este es el contexto en el que se ha desarrollado la presente tesis doctoral. La topología del flujo sobre la isla de Bolund ha sido estudiada mediante la reproducción del experimento de Bolund en los túneles aerodinámicos A9 y ACLA16 del IDR. Dos modelos de la isla de Bolund fueron fabricados a dos escalas, 1:230 y 1:115. El flujo de entrada en el túnel aerodinámico simulando la capa límite sin perturbar correspondía a régimen de transición (transitionally rough regime) y fue usado como situación de referencia. El modelo a escala 1:230 fue ensayado en el túnel A9 para determinar la presión sobre su superficie. La distribución del coeficiente de presión sobre la isla proporcionó una visualización y estimación de una región de desprendimiento sobre el pequeño acantilado situado al frente de la misma. Las medidas de presión instantánea con suficiente grado de resolución temporal pusieron de manifiesto la no estacionariedad en la región de desprendimiento. El modelo a escala 1:115 fue ensayado utilizando hilo caliente de tres componentes y un sistema de velocimetría por imágenes de partículas de dos componentes. El flujo fue caracterizado por el ratio de aceleración, el incremento normalizado de energía cinética turbulenta y los ángulos de inclinación y desviación horizontal. Los resultados a lo largo de la dirección 270°y alturas de 2 m y 5 m presentaron una gran similitud con los resultados a escala real del experimento de Bolund. Los perfiles verticales en las localizaciones de las torres meteorológicas mostraron un acuerdo significativo con los resultados a escala real. El análisis de los esfuerzos de Reynolds y el análisis espectral en las localizaciones de los mástiles meteorológicos presentaron niveles de acuerdo variados en ciertas posiciones, mientras que en otras presentaron claras diferencias. El mapeo horizontal del flujo, para una dirección de viento de 270°, permitió caracterizar el comportamiento de la burbuja intermitente de recirculación sobre el pequeño acantilado existente al frente de la isla así como de la región de relajación y de la capa de cortadura en la región corriente abajo de Bolund. Se realizaron medidas de velocidad con alta resolución espacial en planos perpendiculares a la dirección del flujo sin perturbar. Estas medidas permitieron detectar y caracterizar una estructura de flujo similar a un torbellino longitudinal con regiones con altos gradientes de velocidad y alta intensidad de turbulencia. Esta estructura de flujo es, sin duda, un reto para los modelos computacionales y puede considerarse un factor de riesgo para la operación de los aerogeneradores. Se obtuvieron y analizaron distribuciones espaciales de los esfuerzos de Reynolds mediante 3CHW y PIV. Este tipo de parámetros no constituyen parte de los resultados habituales en los ensayos en túnel sobre topografías y son muy útiles para los modelizadores que utilizan simulación de grades torbellinos (LES). Se proporciona una interpretación de los resultados obtenidos en el túnel aerodinámico en términos de utilidad para los diseñadores de parques eólicos. La evolución y variación de los parámetros del flujo a lo largo de líneas, planos y superficies han permitido identificar como estas propiedades del flujo podrían afectar la localización de los aerogeneradores y a la clasificación de emplazamientos. Los resultados presentados sugieren, bajo ciertas condiciones, la robustez de los ensayos en túnel para estudiar la topología sobre terreno complejo y su comparabilidad con otras técnicas de simulación, especialmente considerando el nivel de acuerdo del conjunto de resultados presentados con los resultados a escala real. De forma adicional, algunos de los parámetros del flujo obtenidos de las medidas en túnel son difícilmente determinables en ensayos a escala real o por medios computacionales, considerado el estado del arte. Este trabajo fue realizado como parte de las actividades subvencionadas por la Comisión Europea como dentro del proyecto FP7-PEOPLE-ITN-2008WAUDIT (Wind Resource Assessment Audit and Standardization) dentro de la FP7 Marie-Curie Initial Training Network y por el Ministerio Español de Economía y Competitividad dentro del proyecto ENE2012-36473, TURCO (Determinación en túnel aerodinámico de la distribución espacial de parámetros estadísticos de la turbulencia atmosférica sobre topografías complejas) del Plan Nacional de Investigación (Subprograma de investigación fundamental no orientada 2012). El informe se ha organizado en siete capítulos y un conjunto de anexos. En el primer capítulo se introduce el problema. En el capítulo dos se describen los medios experimentales utilizados. Seguidamente, en el capítulo tres, se analizan en detalle las condiciones de referencia del principal túnel aerodinámico utilizado en esta investigación. En el capítulo tres se presentan resultados de ensayos de presión superficial sobre un modelo de la isla. Los principales resultados del experimento de Bolund se reproducen en el capítulo cinco. En el capítulo seis se identifican diferentes estructuras del flujo sobre la isla y, finalmente, en el capitulo siete, se recogen las conclusiones y una propuesta de lineas de trabajo futuras. ABSTRACT The main objective of this work is to contribute to answer the question: to which extend can the wind tunnel testing contribute to determine the flow characteristics that affect the dynamic response of wind turbines operating in highly complex terrains?. This question is not new, indeed, the debate in the scientific community was opened in the first third of the past century and it is still intensely alive. The accepted approach to face this problem consists in analysing a given case study where full-scale tests, computational modelling and wind tunnel testing are applied to the same topography. This is neither easy nor cheap. This is is the reason why since the Askervein experience in 1988, the atmospheric flow modellers community had to wait till 2007 when the Bolund experiment was setup with a deployment of technical means equivalent (considering the evolution of the sensor and computing techniques). The problem is so manifold that both experiences were restricted to neutral conditions without Coriolis effects in order to reduce the complexity. This is the framework in which this PhD has been carried out. The flow topology over the Bolund Island has been studied by replicating the Bolund experiment in the IDR A9 and ACLA16 wind tunnels. Two mock-ups of the Bolund island were manufactured at two scales of 1:230 and 1:115. The in-flow in the empty wind tunnel simulating the incoming atmospheric boundary layer was in the transitionally rough regime and used as a reference case. The 1:230 model was tested in the A9 wind tunnel to measure surface pressure. The mapping of the pressure coefficient across the island gave a visualisation and estimation of a detachment region on the top of the escarpment in front of the island. Time resolved instantaneous pressure measurements illustrated the non-steadiness in the detachment region. The 1:115 model was tested using 3C hot-wires(HW) and 2C Particle Image Velocimetry(PIV). Measurements at met masts M3, M6, M7 and M8 and along Line 270°were taken to replicate the result of the Bolund experiment. The flow was characterised by the speed-up ratio, normalised increment of the turbulent kinetic energy, inclination angle and turning angle. Results along line 270°at heights of 2 m and 5 m compared very well with the full-scale results of the Bolund experiment. Vertical profiles at the met masts showed a significant agreement with the full-scale results. The analysis of the Reynolds stresses and the spectral analysis at the met mast locations gave a varied level of agreement at some locations while clear mismatch at others. The horizontal mapping of the flow field, for a 270°wind direction, allowed to characterise the behaviour of the intermittent recirculation bubble on top of the front escarpment followed by a relaxation region and the presence of a shear layer in the lee side of the island. Further detailed velocity measurements were taken at cross-flow planes over the island to study the flow structures on the island. A longitudinal vortex-like structure with high mean velocity gradients and high turbulent kinetic energy was characterised on the escarpment and evolving downstream. This flow structure is a challenge to the numerical models while posing a threat to wind farm designers when siting wind turbines. Spatial distribution of Reynold stresses were presented from 3C HW and PIV measurements. These values are not common results from usual wind tunnel measurements and very useful for modellers using large eddy simulation (LES). An interpretation of the wind tunnel results in terms of usefulness to wind farm designers is given. Evolution and variation of the flow parameters along measurement lines, planes and surfaces indicated how the flow field could affect wind turbine siting. Different flow properties were presented so compare the level of agreement to full-scale results and how this affected when characterising the site wind classes. The results presented suggest, under certain conditions, the robustness of the wind tunnel testing for studying flow topology over complex terrain and its capability to compare to other modelling techniques especially from the level of agreement between the different data sets presented. Additionally, some flow parameters obtained from wind tunnel measurements would have been quite difficult to be measured at full-scale or by computational means considering the state of the art. This work was carried out as a part of the activities supported by the EC as part of the FP7- PEOPLE-ITN-2008 WAUDIT project (Wind Resource Assessment Audit and Standardization) within the FP7 Marie-Curie Initial Training Network and by the Spanish Ministerio de Economía y Competitividad, within the framework of the ENE2012-36473, TURCO project (Determination of the Spatial Distribution of Statistic Parameters of Flow Turbulence over Complex Topographies in Wind Tunnel) belonging to the Spanish National Program of Research (Subprograma de investigación fundamental no orientada 2012). The report is organised in seven chapters and a collection of annexes. In chapter one, the problem is introduced. In chapter two the experimental setup is described. Following, in chapter three, the inflow conditions of the main wind tunnel used in this piece of research are analysed in detail. In chapter three, preliminary pressure tests results on a model of the island are presented. The main results from the Bolund experiment are replicated in chapter five. In chapter six, an identification of specific flow strutures over the island is presented and, finally, in chapter seven, conclusions and lines for future works related to the presented one are included.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta Tesis presenta un estudio sobre el comportamiento vibroacústico de estructuras espaciales que incluyen capas de aire delgadas, así como sobre su modelización numérica. Las capas de aire pueden constituir un elemento fundamental en estos sistemas, como paneles solares plegados, que se consideran el caso de estudio en este trabajo. Para evaluar la influencia de las capas de aire en la respuesta dinámica del sistema se presenta el uso de modelos unidimensionales. La modelización de estos sistemas se estudia para los rangos de baja y alta frecuencia. En el rango de baja frecuencia se propone un conjunto de estrategias de simulación basadas en técnicas numéricas que se utilizan habitualmente en la industria aeroespacial para facilitar la aplicación de los resultados de la Tesis en los modelos numéricos actuales. Los resultados muestran el importante papel de las capas de aire en la respuesta del sistema. El uso de modelos basados en elementos finitos o de contorno para estos elementos proporciona resultados equivalentes aunque la aplicabilidad de estos últimos puede estar condicionada por la geometría del problema. Se estudia asimismo el uso del Análisis Estadístico de la Energía (SEA) para estos elementos. Una de las estrategias de simulación propuestas, que incluye una formulación energética para el aire que rodea a la estructura, se propone como estimador preliminar de la respuesta del sistema y sus frecuencias propias. Para el rango de alta frecuencia, se estudia la influencia de la definición del propio modelo SEA. Se presenta el uso de técnicas de reducción para determinar una matriz de pérdidas SEA reducida para definiciones incompletas del sistema (si algún elemento que interactúa con el resto no se incluye en el modelo). Esta nueva matriz tiene en cuenta la contribución de las subestructuras que no se consideran parte del modelo y que suelen ignorarse en el procedimiento habitual para reducir el tamaño del mismo. Esta matriz permite también analizar sistemas que incluyen algún componente con problemas de accesibilidad para medir su respuesta. Respecto a la determinación de los factores de pérdidas del sistema, se presenta una metodología que permite abordar casos en los que el método usual, el Método de Inyección de Potencia (PIM), no puede usarse. Se presenta un conjunto de métodos basados en la técnicas de optimización y de actualización de modelos para casos en los que no se puede medir la respuesta de todos los elementos del sistema y también para casos en los que no todos los elementos pueden ser excitados, abarcando un conjunto de casos más amplio que el abordable con el PIM. Para ambos rangos de frecuencia se presentan diferentes casos de análisis: modelos numéricos para validar los métodos propuestos y un panel solar plegado como caso experimental que pone de manifiesto la aplicación práctica de los métodos presentados en la Tesis. ABSTRACT This Thesis presents an study on the vibro-acoustic behaviour of spacecraft structures with thin air layers and their numerical modelling. The air layers can play a key role in these systems as solar wings in folded configuration that constitute the study case for this Thesis. A method based on one-dimensional models is presented to assess the influence of the air layers in the dynamic response of the system. The modelling of such systems is studied for low and high frequency ranges. In the low frequency range a set of modelling strategies are proposed based on numerical techniques used in the industry to facilitate the application of the results in the current numerical models. Results show the active role of the air layers in the system response and their great level of influence. The modelling of these elements by means of Finite Elements (FE) and Boundary Elements (BE) provide equivalent results although the applicability of BE models can be conditioned by the geometry of the problem. The use of Statistical Energy Analysis (SEA) for these systems is also presented. Good results on the system response are found for models involving SEA beyond the usual applicability limit. A simulation strategy, involving energetic formulation for the surrounding fluid is proposed as fast preliminary approach for the system response and the coupled eigenfrequencies. For the high frequency range, the influence of the definition of the SEA model is presented. Reduction techniques are used to determine a Reduced SEA Loss Matrix if the system definition is not complete and some elements, which interact with the rest, are not included. This new matrix takes into account the contribution of the subsystems not considered that are neglected in the usual approach for decreasing the size of the model. It also allows the analysis of systems with accessibility restrictions on some element in order to measure its response. Regarding the determination of the loss factors of a system, a methodology is presented for cases in which the usual Power Injection Method (PIM) can not be applied. A set of methods are presented for cases in which not all the subsystem responses can be measured or not all the subsystems can be excited, as solar wings in folded configuration. These methods, based on error minimising and model updating techniques can be used to calculate the system loss factors in a set of cases wider than the PIM’s. For both frequency ranges, different test problems are analysed: Numerical models are studied to validate the methods proposed; an experimental case consisting in an actual solar wing is studied on both frequency ranges to highlight the industrial application of the new methods presented in the Thesis.