37 resultados para Height Tolerance of Concrete Blocks
Resumo:
A model for chloride transport in concrete is proposed. The model accounts for transport several transport mechanisms such as diffusion, advection, migration, etc. This work shows the chloride transport equations at the macroscopic scale in non-saturated concrete. The equations involve diffusion, migration, capillary suction, chloride combination and precipitation mechanisms. The material is assumed to be infinitely rigid, though the porosity can change under influence of chloride binding and precipitation. The involved microscopic and macroscopic properties of the materials are measured by standardized methods. The variables which must be imposed on the boundaries are temperature, relative humidity and chloride concentration. The output data of the model are the free, bound, precipitated and total chloride ion concentrations, as well as the pore solution content and the porosity. The proposed equations are solved by means of the finite element method (FEM) implemented in MATLAB (classical Galerkin formulation and the streamline upwind Petrov-Galerkin (SUPG) method to avoid spatial instabilities for advection dominated flows).
Resumo:
A través de los años las estructuras de hormigón armado han ido aumentando su cuota de mercado, sustituyendo a las estructuras de fábrica de piedra o ladrillo y restándole participación a las estructuras metálicas. Uno de los primeros problemas que surgieron al ejecutar las estructuras de hormigón armado, era cómo conectar una fase de una estructura de este tipo a una fase posterior o a una modificación posterior. Hasta los años 80-90 las conexiones de una fase de una estructura de hormigón armado, con otra posterior se hacían dejando en la primera fase placas de acero con garrotas embebidas en el hormigón fresco o barras grifadas recubiertas de poliestireno expandido. Una vez endurecido el hormigón se podían conectar nuevas barras, para la siguiente fase mediante soldadura a la placa de la superficie o enderezando las barras grifadas, para embeberlas en el hormigón fresco de la fase siguiente. Estos sistemas requerían conocer la existencia y alcance de la fase posterior antes de hormigonar la fase previa. Además requerían un replanteo muy exacto y complejo de los elementos de conexión. Otro problema existente en las estructuras de hormigón era la adherencia de un hormigón fresco a un hormigón endurecido previamente, ya que la superficie de contacto de ambos hormigones suponía un punto débil, con una adherencia baja. A partir de los años 80, la industria química de la construcción experimentó un gran avance en el desarrollo de productos capaces de generar una buena adherencia sobre el hormigón endurecido. Este avance tecnológico tenía aplicación tanto en la adherencia del hormigón fresco sobre el hormigón endurecido, como en la adherencia de barras post-instaladas en agujeros de hormigón endurecido. Este sistema se denominó “anclajes adherentes de barras de acero en hormigón endurecido”. La forma genérica de ejecutarlos es hacer una perforación cilíndrica en el soporte de hormigón, con una herramienta especifica como un taladro, limpiar la perforación, llenarla del material adherente y finalmente introducir la barra de acero. Los anclajes adherentes se dividen en anclajes cementosos y anclajes químicos, siendo estos últimos los más habituales, fiables, resistentes y fáciles de ejecutar. El uso del anclaje adherente de barras de acero en hormigón endurecido se ha extendido por todo el espectro productivo, siendo muy habitual tanto en construcción de obras de hormigón armado de obra civil y edificación, como en obras industriales, instalaciones o fijación de elementos. La ejecución de un anclaje de una barra de acero en hormigón endurecido depende de numerosas variables, que en su conjunto, o de forma aislada pueden afectar de forma notable a la resistencia del anclaje. Nos referimos a variables de los anclajes, que a menudo no se consideran tales como la dirección de la perforación, la máquina de perforación y el útil de perforación utilizado, la diferencia de diámetros entre el diámetro del taladro y la barra, el tipo de material de anclaje, la limpieza del taladro, la humedad del soporte, la altura del taladro, etc. La utilización en los últimos años de los hormigones Autocompactables, añade una variable adicional, que hasta ahora apenas ha sido estudiada. En línea con lo apuntado, la presente tesis doctoral tiene como objetivo principal el estudio de las condiciones de ejecución en la resistencia de los anclajes en hormigón convencional y autocompactable. Esta investigación se centra principalmente en la evaluación de la influencia de una serie de variables sobre la resistencia de los anclajes, tanto en hormigón convencional como en un hormigón autocompactable. Para este estudio ha sido necesaria la fabricación de dos soportes de hormigón sobre los cuales desarrollar los ensayos. Uno de los bloques se ha fabricado con hormigón convencional y el otro con hormigón autocompactable. En cada pieza de hormigón se han realizado 174 anclajes con barras de acero, variando los parámetros a estudiar, para obtener resultados de todas las variables consideradas. Los ensayos a realizar en ambos bloques son exactamente iguales, para poder comparar la diferencia entre un anclaje en un soporte de hormigón con vibrado convencional (HVC) y un hormigón autocompactante (HAC). De cada tipo de ensayo deseado se harán dos repeticiones en la misma pieza. El ensayo de arrancamiento de las barras se realizara con un gato hidráulico hueco, con un sistema de instrumentación de lectura y registro de datos en tiempo real. El análisis de los resultados, realizado con una potente herramienta estadística, ha permitido determinar y evaluar numéricamente la influencia de los variables consideradas en la resistencia de los anclajes realizados. Así mismo ha permitido diferenciar los resultados obtenidos en los hormigones convencionales y autocompactantes, tanto desde el punto de vista de la resistencia mecánica, como de las deformaciones sufridas en el arrancamiento. Se define la resistencia mecánica de un anclaje, como la fuerza desarrollada en la dirección de la barra, para hacer su arrancamiento del soporte. De la misma forma se considera desplazamiento, a la separación entre un punto fijo de la barra y otro del soporte, en la dirección de la barra. Dichos puntos se determinan cuando se ha terminado el anclaje, en la intersección de la superficie plana del soporte, con la barra. Las conclusiones obtenidas han permitido establecer qué variables afectan a la ejecución de los anclajes y en qué cuantía lo hacen, así como determinar la diferencia entre los anclajes en hormigón vibrado convencional y hormigón autocompactante, con resultados muy interesantes, que permiten valorar la influencia de dichas variables. Dentro de las conclusiones podemos destacar tres grupos, que denominaremos como de alta influencia, baja influencia y sin influencia. En todos los casos hay que hacer el estudio en términos de carga y de desplazamiento. Podemos considerar como de alta influencia, en términos de carga las variables de máquina de perforación y el material de anclaje. En términos de desplazamiento podemos considerar de alta influencia además de la máquina de perforación y el material de anclaje, el diámetro del taladro, así como la limpieza y humedad del soporte. Podemos considerar de baja influencia, en términos de carga las variables de tipo de hormigón, dirección de perforación, limpieza y humedad del soporte. En términos de desplazamiento podemos considerar de baja influencia el tipo de hormigón y la dirección de perforación. Podemos considerar en el apartado de “sin influencia”, en términos de carga las variables de diámetro de perforación y altura del taladro. En términos de desplazamiento podemos considerar como “sin influencia” la variable de altura del taladro. Podemos afirmar que las diferencias entre los valores de carga aumentan de forma muy importante en términos de desplazamiento. ABSTRACT Over the years the concrete structures have been increasing their market share, replacing the masonry structures of stone or brick and subtracting as well the participation of the metallic structures. One of the first problems encountered in the implementing of the reinforced concrete structures was connecting a phase structure of this type at a later stage or a subsequent amendment. Until the 80s and 90s the connections of one phase of a reinforced concrete structure with a subsequent first phase were done by leaving the steel plates embedded in the fresh concrete using hooks or bent bars coated with expanded polystyrene. Once the concrete had hardened new bars could be connected to the next stage by welding them to the surface plate or by straightening the bent bars to embed them in the fresh concrete of the next phase. These systems required a previous knowledge of the existence and scope of the subsequent phase before concreting the previous one. They also required a very precise and complex rethinking of the connecting elements. Another existing problem in the concrete structures was the adhesion of a fresh concrete to a previously hardened concrete, since the contact surface of both concretes leaded to a weak point with low adherence. Since the 80s, the chemicals construction industry experienced a breakthrough in the development of products that generate a good grip on the concrete. This technological advance had its application both in the grip on one hardened fresh concrete and in the adhesion of bar post-installed in holes of hardened concrete. This system was termed as adherent anchors of steel bars in hardened concrete. The generic way of executing this system is by firstly drilling a cylindrical hole in the concrete support using a specific tool such as a drill. Then, cleaning the bore and filling it with bonding material to lastly, introduce the steel bar. These adherent anchors are divided into cement and chemical anchors, the latter being the most common, reliable, durable and easy to run. The use of adhesive anchor of steel bars in hardened concrete has spread across the production spectrum turning itself into a very common solution in both construction of reinforced concrete civil engineering and construction, and industrial works, installations and fixing elements as well. The execution of an anchor of a steel bar in hardened concrete depends on numerous variables which together or as a single solution may significantly affect the strength of the anchor. We are referring to variables of anchors which are often not considered, such as the diameter difference between the rod and the bore, the drilling system, cleansing of the drill, type of anchor material, the moisture of the substrate, the direction of the drill, the drill’s height, etc. During recent years, the emergence of self-compacting concrete adds an additional variable which has hardly been studied so far. According to mentioned this thesis aims to study the main performance conditions in the resistance of conventional and self-compacting concrete anchors. This research is primarily focused on the evaluation of the influence of several variables on the strength of the anchoring, both in conventional concrete and self-compacting concrete. In order to complete this study it has been required the manufacture of two concrete supports on which to develop the tests. One of the blocks has been manufactured with conventional concrete and the other with self-compacting concrete. A total of 174 steel bar anchors have been made in each one of the concrete pieces varying the studied parameters in order to obtain results for all variables considered. The tests to be performed on both blocks are exactly the same in order to compare the difference between an anchor on a stand with vibrated concrete (HVC) and a self-compacting concrete (SCC). Each type of test required two repetitions in the same piece. The pulling test of the bars was made with a hollow jack and with an instrumentation system for reading and recording data in real time. The use of a powerful statistical tool in the analysis of the results allowed to numerically determine and evaluate the influence of the variables considered in the resistance of the anchors made. It has likewise enabled to differentiate the results obtained in the self-compacting and conventional concretes, from both the outlook of the mechanical strength and the deformations undergone by uprooting. The mechanical strength of an anchor is defined as the strength undergone in a direction of the bar to uproot it from the support. Likewise, the movement is defined as the separation between a fixed point of the bar and a fixed point from the support considering the direction of the bar. These points are only determined once the anchor is finished, with the bar, at the intersection in the flat surface of the support. The conclusions obtained have established which variables affect the execution of the anchors and in what quantity. They have also permitted to determine the difference between the anchors in vibrated concrete and selfcompacting concrete with very interesting results that also allow to assess the influence of these mentioned variables. Three groups are highlighted among the conclusions called high influence, low influence and no influence. In every case is necessary to perform the study in terms of loading and movement. In terms of loading, there are considered as high influence two variables: drilling machinery and anchorage material. In terms of movement, there are considered as high influence the drilling diameter and the cleaning and moisture of the support, besides the drilling machinery and the anchorage material. Variables such as type of concrete, drilling direction and cleaning and moisture of the support are considered of low influence in terms of load. In terms of movement, the type of concrete and the direction of the drilling are considered variables of low influence. Within the no influence section in terms of loading, there are included the diameter of the drilling and the height of the drill. In terms of loading, the height of the drill is considered as a no influence variable. We can affirm that the differences among the loading values increase significantly in terms of movement.
Resumo:
Este artículo estudia el proceso de fisuración del hormigón por corrosión de la armadura. Se presenta un modelo de transporte de cloruros en el hormigón, que contempla la no-linealidad de los coeficientes de difusión, las isotermas de absorción y el fenómeno de convección. A partir de los resultados de penetración de cloruros, se establece la corrosión de la armadura con la consiguiente expansión radial. La fisuración del hormigón se estudia con un modelo de fisura embebida. Los dos modelos (iniciación y propagación) se incorporan en un programa de elementos finitos. El modelo se contrasta con resultados experimentales, obteniéndose un buen ajuste. Una de las dificultades es establecer el umbral de concentración de cloruros que da lugar al inicio de la corrosión de la armadura.This paper is focused on the chloride-induced corrosion of the rebar in RC. A comprehensive model for the chloride ingress into concrete is presented, with special attention to non-linear diffusion coefficients, chloride binding isotherms and convection phenomena. Based on the results of chloride diffusion, subsequent active corrosion is assumed and the radial expansion of the corroded reinforcement reproduced. For cracking simulation, the Strong Discontinuity Approach is applied. Both models (initiation and propagation corrosion stages) are incorporated in the same finite element program and chained. Comparisons with experimental results are carried out, with reasonably good agreements being obtained, especially for cracking patterns. Major limitations refer to difficulties to establish precise levels of basic data such as the chloride ion content at concrete surface, the chloride threshold concentration that triggers active corrosion, the rate of oxide production or the rust mechanical properties.
Resumo:
The Barriga Dam (Burgos, Spain) is a unique case study because its trapezoid spillway is located on the dam body and is composed of wedge-shaped concrete blocks (WSB) that include certain relevant improvements. This note summarizes the main features of the studies, the key aspects of the final design of the WSB and their placement on the dam, and important details of the spillway design. The design team concluded the study by showing the suitability of this enhanced technology for application to small dams and ponds in the short term, even with unit flows above 5 m2/s.
Resumo:
The installation of offshore scour protection systems in offshore wind farms allows avoid the effect of scour phenomenon around these structures. Up to date, numerous research projects have been carried out to justify the necessity of the scour protection systems and also to optimize their design. Protection systems based on riprap is frequently used due to its low cost and easy availability compared to other solutions such as geotextile bags or prefabricated concrete blocks. The sizing of these structures can be performed according to a series of recommendations that can optimize the costs associated with them, but there have been only few studies with real data up to now which have allowed identify the need for such protections. This investigation aims to assess the functionality of the scour protections adopted through the available data about their characteristics and the scour depth developed around the foundations. In this sense, this paper presents the results of a study that analyzes the functionality of scour protections in different European offshore wind farms.
Resumo:
En esta tesis se presenta una metodología para la caracterización del oleaje, dentro del marco de las nuevas Recomendaciones para Obras Marítimas (ROM 0.0.-00 y ROM 1.0-09), por ser una de las principales acciones que afectan a la estabilidad de las estructuras marítimas. Debido al carácter aleatorio intrínsecamente multivariado de la acción considerada, las tormentas, su caracterización paramétrica se realiza en términos de funciones cópula uniparamétricas. Las variables consideradas son altura de ola significante del pico de la tormenta, el periodo medio asociado y la magnitud, o número de olas, de todo el ciclo de solicitación. Para establecer un patrón teórico de evolución de la tormenta que permita extrapolar las muestras fuera de la región con datos se analizan los modelos teóricos existentes, comprobándose que no reproducen adecuadamente las tormentas constituidas por estados de mar con un peso importante de oleaje swell. Para evitar esta limitación se proponen cuatro modelos teóricos de evolución de tormentas con distintas formas geométricas. El análisis de los modelos existentes y los propuestos pone de relieve que el Modelo Magnitud Equivalente de Tormenta (EMS= Equivalent Magnitude Storm) con la forma triangular es el que mejor adapta las tormentas constituidas por estados de mar típicos del viento. Para tormentas con un mayor grado de desarrollo, el modelo teórico de tormenta EMS con la forma trapezoidal es el adecuado. De las aproximaciones propuestas para establecer el periodo medio de los sucesivos estados de mar del ciclo de solicitación. la propuesta por Martín Soldevilla et al., (2009) es la más versátil y , en general , mejor reproduce la evolución de todo tipo de tormentas. La caracterización de las tormentas se complementa con la altura de ola máxima. Debido a la mayor disponibilidad y longitud temporal de los datos sintéticos frente a las registros, la práctica totalidad de los análisis de extremos se realizan con tormentas sintéticas en las que la distribución de olas individuales es desconocida. Para evitar esta limitación se utilizan modelos teóricos de distribución de olas acordes a las características de cada uno de los estados de mar que conforman la tormenta sintética. Para establecer dichas características se utiliza la curtosis y en función de su valor la altura de ola máxima se determina asumiendo una determinada distribución de olas. Para estados de mar lineales la distribución de olas individuales de Rayleigh es la considerada. Para condiciones no lineales de gran ancho de banda el modelo de distribución de olas propuesto por Dawson, (2004) es el utilizado y si es de banda estrecha las predicciones de (Boccotti, (1989), Boccotti et al., (2013)) se compara con las resultantes del modelo de Dawson. La caracterización de la evolución de las tormentas en términos multivariados es aplicada al estudio de la progresión del daño del manto principal de diques en talud, y al rebase de las olas. Ambos aspectos cubren el segundo objetivo de la tesis en el que se propone una nueva formulación para el dimensionamiento de mantos constituidos por bloques cúbicos de hormigón. Para el desarrollo de esta nueva formulación se han utilizado los resultados recogidos en los estudios de estabilidad del manto principal de diques talud realizados en modelo físico a escala reducida en el Centro de Estudios de Puertos y Costas (CEDEX) desde la década de los 80 empleando, en su mayoría, bloques paralelepípedos cúbicos de hormigón. Por este motivo y porque los últimos diques construidos en la costa Española utilizan este tipo de pieza, es por lo que la formulación planteada se centra en este tipo de pieza. Después de un primer análisis de las fórmulas de cálculo y de evolución existentes, se llega a la conclusión de que es necesario realizar un esfuerzo de investigación en este campo, así como ensayos en laboratorio y recogida de datos in-situ con base a desarrollar fórmulas de evolución de daño para mantos constituidos por piezas diferentes a la escollera, que tenga en cuenta las principales variables que condiciona su estabilidad. En esta parte de la tesis se propone un método de análisis de evolución de daño, que incluye el criterio de inicio de avería, adecuada para diques en talud constituidos por bloque cúbicos de hormigón y que considera la incidencia oblicua, el daño acumulado y el rebase. This thesis proposes a methodology to estimate sea waves, one of the main actions affecting the maritime structures stability, complying with (ROM 0.0.-00 & ROM 1.0-09.Due to the multivariate behavior of sea storms, the characterization of the structures of sea storms is done using copula function. The analyzed variables are the significant height wave, mean period and magnitude or number of waves during the storm history. The storm evolution in terms of the significant height wave and the mean period is also studied in other to analyze the progressive failure modes. The existing models of evolution are studied, verifying that these approximations do not adjust accurately for developed waves. To overcome this disadvantage, four evolution models are proposed, with some geometrical shapes associated to fit any development degree. The proposed Equivalent Magnitude Storm model, EMS, generally obtains the best results for any kind of storm (predominant sea, swell or both). The triangle is recommended for typical sea storms whereas the trapezoid shape is much more appropriate for more developed storm conditions.The Martín Soldevilla et al., (2009) approach to estimate the mean period is better than others approaches used.The storm characterization is completed with the maximum wave height of the whole storm history. Due to synthetic historical waves databases are more accessible and longer than recorded database, the extreme analyses are done with synthetic data. For this reason the individual waves’ distribution is not known. For that limitation to be avoided, and depending on the characteristics of every sea states, one theoretical model of waves is choose and used. The kurtosis parameter is used to distinguish between linear and nonlinear sea states. The Rayleigh model is used for the linear sea states. For the nonlinear sea states, Dawson, (2004) approach is used for non-narrow bandwidth storms, comparing the results with the Boccotti, (1989), Boccotti et al., (2013) approach, with is used for narrow bandwidth storms. The multivariate and storm evolution characterization is used to analyze of stone armour damage progression and wave overtopping discharge. Both aspects are included in the second part of the thesis, with a new formula is proposed to design cubes armour layer. The results the stability studies of armour layer, done in the Centre for Harbours and Coastal Studies (CEDEX) laboratory are used for defining a new stability formula. For this reason and because the last biggest breakwater built in Spain using the cube, the damage progression is analyze for this kind of concrete block. Before to analyze the existing formulae, it is concluded that it is necessary more investigation, more tests in laboratory and data gathering in situ to define damage evolution formulae to armour of other kind of pieces and that takes to account the principal variables. This thesis proposed a method to calculate the damage progression including oblique waves, accumulated damage, and overtopping effect. The method also takes account the beginning of the movement of the blocks.
Resumo:
The carbonation of concrete or the chlorides ingress in such quantity to reach the level of bars is triggers of reinforcement corrosion. One of the most significant effects of reinforcing steel corrosion on reinforced concrete structures is the decline in the ductility-related properties of the steel. Reinforcement ductility has a decisive effect on the overall ductility of reinforced concrete structures. Different Codes classify the type of steel depending on their ductility defined by the minimum values of several parameters. Using indicators of ductility associating different properties can be advantageous on many occasions. It is considered necessary to define the ductility by means of a single parameter that considers strength values and deformation simultaneously. There are a number of criteria for defining steel ductility by a single parameter. The present experimental study addresses the variation in the ductility of concrete-embedded steel bars when exposed to accelerated corrosion. This paper analyzes the suitability of a new indicator of ductility used in corroded bars.