83 resultados para Distributed systems, modeling, composites, finite elements
Resumo:
Civil buildings are not specifically designed to support blast loads, but it is important to take into account these potential scenarios because of their catastrophic effects, on persons and structures. A practical way to consider explosions on reinforced concrete structures is necessary. With this objective we propose a methodology to evaluate blast loads on large concrete buildings, using LS-DYNA code for calculation, with Lagrangian finite elements and explicit time integration. The methodology has three steps. First, individual structural elements of the building like columns and slabs are studied, using continuum 3D elements models subjected to blast loads. In these models reinforced concrete is represented with high precision, using advanced material models such as CSCM_CONCRETE model, and segregated rebars constrained within the continuum mesh. Regrettably this approach cannot be used for large structures because of its excessive computational cost. Second, models based on structural elements are developed, using shells and beam elements. In these models concrete is represented using CONCRETE_EC2 model and segregated rebars with offset formulation, being calibrated with continuum elements models from step one to obtain the same structural response: displacement, velocity, acceleration, damage and erosion. Third, models basedon structural elements are used to develop large models of complete buildings. They are used to study the global response of buildings subjected to blast loads and progressive collapse. This article carries out different techniques needed to calibrate properly the models based on structural elements, using shells and beam elements, in order to provide results of sufficient accuracy that can be used with moderate computational cost.
Resumo:
The broadcast service spreads a message m among all processes of the system, such that each process eventually delivers m. A basic broadcast service does not impose any delivery guarantee in a system with failures. Fault-tolerant broadcast is a fundamental problem in distributed systems that adds certainty in the delivery of messages when crashes can happen in the system. Traditionally, the fault-tolerant broadcast service has been studied in classical distributed systems when each process has a unique identity (eponymous system). In this paper we study the fault-tolerant broadcast service in anonymous systems, that is, in systems where all processes are indistinguishable.
Resumo:
In classical distributed systems, each process has a unique identity. Today, new distributed systems have emerged where a unique identity is not always possible to be assigned to each process. For example, in many sensor networks a unique identity is not possible to be included in each device due to its small storage capacity, reduced computational power, or the huge number of devices to be identified. In these cases, we have to work with anonymous distributed systems where processes cannot be identified. Consensus cannot be solved in classical and anonymous asynchronous distributed systems where processes can crash. To bypass this impossibility result, failure detectors are added to these systems. It is known that ? is the weakest failure detector class for solving consensus in classical asynchronous systems when amajority of processes never crashes. Although A? was introduced as an anonymous version of ?, to find the weakest failure detector in anonymous systems to solve consensus when amajority of processes never crashes is nowadays an open question. Furthermore, A? has the important drawback that it is not implementable. Very recently, A? has been introduced as a counterpart of ? for anonymous systems. In this paper, we show that the A? failure detector class is strictly weaker than A? (i.e., A? provides less information about process crashes than A?). We also present in this paper the first implementation of A? (hence, we also show that A? is implementable), and, finally, we include the first implementation of consensus in anonymous asynchronous systems augmented with A? and where a majority of processes does not crash.
Resumo:
Although context could be exploited to improve performance, elasticity and adaptation in most distributed systems that adopt the publish/subscribe (P/S) communication model, only a few researchers have focused on the area of context-aware matching in P/S systems and have explored its implications in domains with highly dynamic context like wireless sensor networks (WSNs) and IoT-enabled applications. Most adopted P/S models are context agnostic or do not differentiate context from the other application data. In this article, we present a novel context-aware P/S model. SilboPS manages context explicitly, focusing on the minimization of network overhead in domains with recurrent context changes related, for example, to mobile ad hoc networks (MANETs). Our approach represents a solution that helps to efficiently share and use sensor data coming from ubiquitous WSNs across a plethora of applications intent on using these data to build context awareness. Specifically, we empirically demonstrate that decoupling a subscription from the changing context in which it is produced and leveraging contextual scoping in the filtering process notably reduces (un)subscription cost per node, while improving the global performance/throughput of the network of brokers without fltering the cost of SIENA-like topology changes.
Resumo:
La frecuencia con la que se producen explosiones sobre edificios, ya sean accidentales o intencionadas, es reducida, pero sus efectos pueden ser catastróficos. Es deseable poder predecir de forma suficientemente precisa las consecuencias de estas acciones dinámicas sobre edificaciones civiles, entre las cuales las estructuras reticuladas de hormigón armado son una tipología habitual. En esta tesis doctoral se exploran distintas opciones prácticas para el modelado y cálculo numérico por ordenador de estructuras de hormigón armado sometidas a explosiones. Se emplean modelos numéricos de elementos finitos con integración explícita en el tiempo, que demuestran su capacidad efectiva para simular los fenómenos físicos y estructurales de dinámica rápida y altamente no lineales que suceden, pudiendo predecir los daños ocasionados tanto por la propia explosión como por el posible colapso progresivo de la estructura. El trabajo se ha llevado a cabo empleando el código comercial de elementos finitos LS-DYNA (Hallquist, 2006), desarrollando en el mismo distintos tipos de modelos de cálculo que se pueden clasificar en dos tipos principales: 1) modelos basados en elementos finitos de continuo, en los que se discretiza directamente el medio continuo mediante grados de libertad nodales de desplazamientos; 2) modelos basados en elementos finitos estructurales, mediante vigas y láminas, que incluyen hipótesis cinemáticas para elementos lineales o superficiales. Estos modelos se desarrollan y discuten a varios niveles distintos: 1) a nivel del comportamiento de los materiales, 2) a nivel de la respuesta de elementos estructurales tales como columnas, vigas o losas, y 3) a nivel de la respuesta de edificios completos o de partes significativas de los mismos. Se desarrollan modelos de elementos finitos de continuo 3D muy detallados que modelizan el hormigón en masa y el acero de armado de forma segregada. El hormigón se representa con un modelo constitutivo del hormigón CSCM (Murray et al., 2007), que tiene un comportamiento inelástico, con diferente respuesta a tracción y compresión, endurecimiento, daño por fisuración y compresión, y rotura. El acero se representa con un modelo constitutivo elastoplástico bilineal con rotura. Se modeliza la geometría precisa del hormigón mediante elementos finitos de continuo 3D y cada una de las barras de armado mediante elementos finitos tipo viga, con su posición exacta dentro de la masa de hormigón. La malla del modelo se construye mediante la superposición de los elementos de continuo de hormigón y los elementos tipo viga de las armaduras segregadas, que son obligadas a seguir la deformación del sólido en cada punto mediante un algoritmo de penalización, simulando así el comportamiento del hormigón armado. En este trabajo se denominarán a estos modelos simplificadamente como modelos de EF de continuo. Con estos modelos de EF de continuo se analiza la respuesta estructural de elementos constructivos (columnas, losas y pórticos) frente a acciones explosivas. Asimismo se han comparado con resultados experimentales, de ensayos sobre vigas y losas con distintas cargas de explosivo, verificándose una coincidencia aceptable y permitiendo una calibración de los parámetros de cálculo. Sin embargo estos modelos tan detallados no son recomendables para analizar edificios completos, ya que el elevado número de elementos finitos que serían necesarios eleva su coste computacional hasta hacerlos inviables para los recursos de cálculo actuales. Adicionalmente, se desarrollan modelos de elementos finitos estructurales (vigas y láminas) que, con un coste computacional reducido, son capaces de reproducir el comportamiento global de la estructura con una precisión similar. Se modelizan igualmente el hormigón en masa y el acero de armado de forma segregada. El hormigón se representa con el modelo constitutivo del hormigón EC2 (Hallquist et al., 2013), que también presenta un comportamiento inelástico, con diferente respuesta a tracción y compresión, endurecimiento, daño por fisuración y compresión, y rotura, y se usa en elementos finitos tipo lámina. El acero se representa de nuevo con un modelo constitutivo elastoplástico bilineal con rotura, usando elementos finitos tipo viga. Se modeliza una geometría equivalente del hormigón y del armado, y se tiene en cuenta la posición relativa del acero dentro de la masa de hormigón. Las mallas de ambos se unen mediante nodos comunes, produciendo una respuesta conjunta. En este trabajo se denominarán a estos modelos simplificadamente como modelos de EF estructurales. Con estos modelos de EF estructurales se simulan los mismos elementos constructivos que con los modelos de EF de continuo, y comparando sus respuestas estructurales frente a explosión se realiza la calibración de los primeros, de forma que se obtiene un comportamiento estructural similar con un coste computacional reducido. Se comprueba que estos mismos modelos, tanto los modelos de EF de continuo como los modelos de EF estructurales, son precisos también para el análisis del fenómeno de colapso progresivo en una estructura, y que se pueden utilizar para el estudio simultáneo de los daños de una explosión y el posterior colapso. Para ello se incluyen formulaciones que permiten considerar las fuerzas debidas al peso propio, sobrecargas y los contactos de unas partes de la estructura sobre otras. Se validan ambos modelos con un ensayo a escala real en el que un módulo con seis columnas y dos plantas colapsa al eliminar una de sus columnas. El coste computacional del modelo de EF de continuo para la simulación de este ensayo es mucho mayor que el del modelo de EF estructurales, lo cual hace inviable su aplicación en edificios completos, mientras que el modelo de EF estructurales presenta una respuesta global suficientemente precisa con un coste asumible. Por último se utilizan los modelos de EF estructurales para analizar explosiones sobre edificios de varias plantas, y se simulan dos escenarios con cargas explosivas para un edificio completo, con un coste computacional moderado. The frequency of explosions on buildings whether they are intended or accidental is small, but they can have catastrophic effects. Being able to predict in a accurate enough manner the consequences of these dynamic actions on civil buildings, among which frame-type reinforced concrete buildings are a frequent typology is desirable. In this doctoral thesis different practical options for the modeling and computer assisted numerical calculation of reinforced concrete structures submitted to explosions are explored. Numerical finite elements models with explicit time-based integration are employed, demonstrating their effective capacity in the simulation of the occurring fast dynamic and highly nonlinear physical and structural phenomena, allowing to predict the damage caused by the explosion itself as well as by the possible progressive collapse of the structure. The work has been carried out with the commercial finite elements code LS-DYNA (Hallquist, 2006), developing several types of calculation model classified in two main types: 1) Models based in continuum finite elements in which the continuous medium is discretized directly by means of nodal displacement degrees of freedom; 2) Models based on structural finite elements, with beams and shells, including kinematic hypothesis for linear and superficial elements. These models are developed and discussed at different levels: 1) material behaviour, 2) response of structural elements such as columns, beams and slabs, and 3) response of complete buildings or significative parts of them. Very detailed 3D continuum finite element models are developed, modeling mass concrete and reinforcement steel in a segregated manner. Concrete is represented with a constitutive concrete model CSCM (Murray et al., 2007), that has an inelastic behaviour, with different tension and compression response, hardening, cracking and compression damage and failure. The steel is represented with an elastic-plastic bilinear model with failure. The actual geometry of the concrete is modeled with 3D continuum finite elements and every and each of the reinforcing bars with beam-type finite elements, with their exact position in the concrete mass. The mesh of the model is generated by the superposition of the concrete continuum elements and the beam-type elements of the segregated reinforcement, which are made to follow the deformation of the solid in each point by means of a penalty algorithm, reproducing the behaviour of reinforced concrete. In this work these models will be called continuum FE models as a simplification. With these continuum FE models the response of construction elements (columns, slabs and frames) under explosive actions are analysed. They have also been compared with experimental results of tests on beams and slabs with various explosive charges, verifying an acceptable coincidence and allowing a calibration of the calculation parameters. These detailed models are however not advised for the analysis of complete buildings, as the high number of finite elements necessary raises its computational cost, making them unreliable for the current calculation resources. In addition to that, structural finite elements (beams and shells) models are developed, which, while having a reduced computational cost, are able to reproduce the global behaviour of the structure with a similar accuracy. Mass concrete and reinforcing steel are also modeled segregated. Concrete is represented with the concrete constitutive model EC2 (Hallquist et al., 2013), which also presents an inelastic behaviour, with a different tension and compression response, hardening, compression and cracking damage and failure, and is used in shell-type finite elements. Steel is represented once again with an elastic-plastic bilineal with failure constitutive model, using beam-type finite elements. An equivalent geometry of the concrete and the steel is modeled, considering the relative position of the steel inside the concrete mass. The meshes of both sets of elements are bound with common nodes, therefore producing a joint response. These models will be called structural FE models as a simplification. With these structural FE models the same construction elements as with the continuum FE models are simulated, and by comparing their response under explosive actions a calibration of the former is carried out, resulting in a similar response with a reduced computational cost. It is verified that both the continuum FE models and the structural FE models are also accurate for the analysis of the phenomenon of progressive collapse of a structure, and that they can be employed for the simultaneous study of an explosion damage and the resulting collapse. Both models are validated with an experimental full-scale test in which a six column, two floors module collapses after the removal of one of its columns. The computational cost of the continuum FE model for the simulation of this test is a lot higher than that of the structural FE model, making it non-viable for its application to full buildings, while the structural FE model presents a global response accurate enough with an admissible cost. Finally, structural FE models are used to analyze explosions on several story buildings, and two scenarios are simulated with explosive charges for a full building, with a moderate computational cost.
Resumo:
We present and analyze a subgrid viscosity Lagrange-Galerk in method that combines the subgrid eddy viscosity method proposed in W. Layton, A connection between subgrid scale eddy viscosity and mixed methods. Appl. Math. Comp., 133: 14 7-157, 2002, and a conventional Lagrange-Galerkin method in the framework of P1⊕ cubic bubble finite elements. This results in an efficient and easy to implement stabilized method for convection dominated convection diffusion reaction problems. Numerical experiments support the numerical analysis results and show that the new method is more accurate than the conventional Lagrange-Galerkin one.
Resumo:
El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.
Resumo:
La hipótesis de partida de esta tesis es que existe una influencia directa entre la técnica que se desarrolla durante el segundo período del s. XIX y el cambio sustancial de los conceptos y de la teoría arquitectónica que se da en esos mismos años. Dicha influencia genera nuevos modelos constructivos que serán la base de la arquitectura moderna. Para llegar a la confirmación de la hipótesis, se han planteado tres objetivos principales que responden a los tres capítulos principales de la misma. En primera instancia, se establecen las condiciones teóricas del debate arquitectónico entre las fechas estudiadas. Se analiza el concepto de modelo y «estilo» para evaluar si, efectivamente, hubo cambio o no. También se analizará si los arquitectos eran conscientes de la necesidad de una nueva arquitectura que respondiese a la funcionalidad que el progreso requería. Para comprobar que dicho cambio se ha producido a todos los niveles hasta el punto de redefinir el modelo constructivo se escoge un ejemplo práctico que cumpla las condiciones necesarias para sustentar o no la tesis y se investiga sobre si sucede o no el cambio. A continuación, se analizará la situación de la técnica y de los avances tecnológicos en el período estudiado. Es importante contrastar que realmente hay un conocimiento y una conciencia verdadera de cambio entre los teóricos y los arquitectos que están construyendo en ese momento. Confirmar que dicha conexión existe es vital para la investigación; para eso, se analizará y se profundizará en las conexiones entre la arquitectura y la ingeniería (o los avances tecnológicos) para entender la implicación de uno con el otro. Con este fin, se han estudiado las distintas publicaciones periódicas de la época; sobre todo la más relevante y la que primero se editó, que fue La revue générale de l’architecture; me he apoyado en ella. Es un documento que mensualmente recoge cambios, avances y debates. Tuvo una grandísima divulgación; todo docente, arquitecto e ingeniero de la época tenía un acceso fácil y directo a dicha publicación. Por último, a raíz de una construcción ideal proyectada por uno de los grandes arquitectos teóricos de la época, se reflexiona sobre si esa arquitectura supone realmente una comprensión y una conciencia de los nuevos modelos arquitectónicos, definidos por una técnica en progreso, o si responde exclusivamente a una utopía arquitectónica como tantas otras se habían esbozado con anterioridad por grandes teóricos. Para poder definir la geometría de este elemento estructural, se ha realizado un modelado tridimensional que permite calcular la estructura a través de un proceso de elementos finitos. El propósito de este cálculo no es exclusivamente saber si la estructura era viable o no en aquella época, sino también comprender si la definición de estos originales elementos estructurales implicaba una concepción nueva de las estructuras tridimensionales y eso significa que empezaba a germinar un cambio sustancial en la teoría de la arquitectura, con la búsqueda de un nuevo modelo constructivo derivado de los avances técnicos. De este modo queda demostrado que el modelo constructivo ha cambiado definitivamente por un modelo mucho más versátil y sobre todo con una gran capacidad de adaptación, esto combinado a su vez con una proliferación de patentes que intentan y buscan una estandarización del modelo constructivo y que no son, en ningún caso, un modelo en sí. Como última conclusión, queda argumentado que en aquella época ya se tenía una gran intuición estructural; a pesar de que el cálculo matemático era todavía algo relativamente nuevo, se manejaban de forma instintiva líneas de cargas, combinación de materiales y nuevas formas, que ayudarán a crear los modelos de los próximos años y que serán la base del cálculo numérico posterior. ABSTRACT The hypothesis of this thesis is that there is a direct influence between the technique developed during the second period of the XIX century and the substantial change in the concepts and in the architectural theory that occurs in those years. This influence develops new building models that will be the basis of modern architecture. To confirm this hypothesis, we present three principal objectives that corresponds to the three principals chapsters of the text. First, we establish the theoretical conditions of the architectural debate between the dates studied. We analyze the concepts of model and “style” to assess whether there was a change or not. We consider as well if architects were aware of the need for a new architecture to respond to the functionality needs that progress demanded. To verify that the change occurred at all levels to the extent of redefining the building model we choose a practical example that fulfills the necessary conditions to support or not the thesis and we investigate whether or not the change happens. Next, we analyze the status of technical and technological advances in the study period of study. It is important to contrast that there is a real knowledge and awareness of change between the theorists and architects who are building at the time. Confirming that that connection exists is vital for the research; for that, we will analyze and deepen into the connections between architecture and engineering (or technological progress) to understand the implication of one into the other. To this end, we have studied various publications of the time; especially the most relevant and the first published, La Revue générale de l’architecture; I have relied on it. This is a monthly document that includes changes, developments and debates. It had a very great disclosure; every teacher, architect and engineer of the time had a direct and easy access to this publication. Finally, following theoretical ideal construction projected by one of the great architects of the time, we reflect on whether that architecture really represents an understanding and awareness of the new architectural models defined by a technique in progress, or if it only responds to an architectural utopia as the ones outlined earlier by the great theorists. To be able to define the geometry of this structural item, we have carried out a three-dimensional modeling that enables us to calculate the structure through a process of finite elements. The purpose of this calculation is not exclusively understanding whether the structure was viable or not at the time, but also understanding if the definition of these original structural elements involved a new concept of three-dimensional structures and if that involved the beginning of a substantial change in theory of architecture, with the search for a new construction model derived from technical advances. In this way it is demonstrated that the building model has definitely changed for a much more versatile one and above all with a high adaptation capacity, this combined in turn with a proliferation of patents that try and seek a standardization of the building model and are not, in any case, a model in itself. As a final conclusion, it is argued that at the time a major structural intuition was present; even though the math calculation was still relatively new, in an instinctively way load lines, combination of materials and new forms were taken into account, that will help to create models in the coming years and which will form the basis of subsequent numerical calculation.
Resumo:
La expansión experimentada por la informática, las nuevas tecnologías e internet en los últimos años, no solo viene dada por la evolución del hardware subyacente, sino por la evolución del desarrollo de software y del crecimiento del número de desarrolladores. Este incremento ha hecho evolucionar el software de unos sistemas de gestión basados en ficheros, prácticamente sin interfaz gráfico y de unos pocos miles de líneas a grandes sistemas distribuidos multiplataforma. El desarrollo de estos grandes sistemas, requiere gran cantidad de personas involucradas en el desarrollo, y que las herramientas de desarrollo hayan crecido también para facilitar su análisis, diseño, codificación, pruebas, implantación y mantenimiento. La base de estas herramientas software las proveen las propias plataformas de desarrollo, pero la experiencia de los desarrolladores puede aportar un sinfín de utilidades y de técnicas que agilicen los desarrollos y cumplan los requisitos del software en base a la reutilización de soluciones lo suficientemente probadas y optimizadas. Dichas herramientas se agrupan ordenadamente, creando así frameworks personalizados, con herramientas de todo tipo, clases, controles, interfaces, patrones de diseño, de tal manera que se dan soluciones personalizadas a un amplio número de problemas para emplearlas cuantas veces se quiera, bien marcando directrices de desarrollo mediante el uso de patrones, bien con la encapsulación de complejidades de tal modo que los desarrolladores ya dispongan de componentes que asuman cierta lógica o cierta complejidad aliviando así la fase de construcción. En este trabajo se abordan temas sobre las tecnologías base y plataformas de desarrollo para poder acometer la creación de un framework personalizado, necesidades a evaluar antes de acometerlo, y técnicas a emplear para la consecución del mismo, orientadas a la documentación, mantenimiento y extensión del framework. La exposición teórica consiste en mostrar y evaluar los requisitos para crear un framework, requisitos de la plataforma de desarrollo, y explicar cómo funcionan las grandes plataformas de desarrollo actuales, que elementos los componen y su funcionamiento, así como marcar ciertas pautas de estructuración y nomenclatura que el desarrollo de un framework debe contemplar para su mantenimiento y extensión. En la parte metodológica se ha usado un subconjunto de Métrica V3, ya que para el desarrollo de controles no aplica dicha metodología en su totalidad, pero contempla el catálogo de requisitos, los casos de uso, diagramas de clase, diagramas de secuencia, etc… Aparte de los conceptos teóricos, se presenta un caso práctico con fines didácticos de cómo parametrizar y configurar el desarrollo bajo la plataforma .NET. Dicho caso práctico consiste en la extensión de un control de usuario genérico de la plataforma .NET, de tal modo que se aplican conceptos más allá del hecho de crear funciones como las funcionalidades que puede brindar un API. Conceptos sobre como extender y modificar controles ya existentes, que interactúan por medio de eventos con otros controles, con vistas a que ese nuevo control forme parte de una biblioteca de controles de usuario personalizados ampliamente divulgada. Los controles de usuario son algo que no solo tienen una parte funcional, sino que también tienen una parte visual, y definiciones funcionales distintas de las típicas del software de gestión, puesto que han de controlar eventos, visualizaciones mientras se dan estos eventos y requisitos no funcionales de optimización de rendimiento, etc… Para el caso práctico se toma como herramienta la plataforma de desarrollo .Net Framework, en todas sus versiones, ya que el control a extender es el control ListView y hacerlo editable. Este control está presente en todas las versiones de .NET framework y con un alto grado de reutilización. Esta extensión muestra además como se puede migrar fácilmente este tipo de extensiones sobre todos los frameworks. Los entornos de desarrollo usados son varias versiones de Visual Studio para el mostrar dicha compatibilidad, aunque el desarrollo que acompaña este documento esté realizado sobre Visual Studio 2013. ABSTRACT The expansion in computer science, new technologies and the Internet in recent years, not only is given by the evolution of the underlying hardware, but for the evolution of software development and the growing number of developers. This increase has evolved software from management systems based on files almost without graphical interface and a few thousand of code lines, to large multiplatform distributed systems. The development of these large systems, require lots of people involved in development, and development tools have also grown to facilitate analysis, design, coding, testing, deployment and maintenance. The basis of these software tools are providing by their own development platforms, but the experience of the developers can bring a lot of utilities and techniques to speed up developments and meet the requirements of software reuse based on sufficiently proven solutions and optimized. These tools are grouped neatly, creating in this way custom frameworks, with tools of all types, classes, controls, interfaces, design patterns,… in such a way that they provide customized solutions to a wide range of problems to use them many times as you want to occur, either by dialing development guidelines by using patterns or along with the encapsulation of complexities, so that developers already have components that take some logic or some complexity relieving the construction phase. This paper cover matters based on technologies and development platforms to undertake the creation of a custom framework, needs to evaluate before rush it and techniques to use in order to achieve it, a part from techniques oriented to documentation, maintenance and framework extension. The theoretical explanation consists in to demonstrate and to evaluate the requirements for creating a framework, development platform requirements, and explain how large current development platforms work, which elements compose them and their operation work, as well as mark certain patterns of structure and nomenclature that the development of a framework should include for its maintenance and extension. In the methodological part, a subset of Métrica V3 has been used, because of, for the development of custom controls this methodology does not apply in its entirety, but provides a catalogue of requirements, use cases, class diagrams, sequence diagrams, etc ... Apart from the theoretical concepts, a study case for teaching purposes about how to parameterize and configure the development under the .NET platform is presented. This study case involves the extension of a generic user control of the .NET platform, so that concepts apply beyond the fact of creating functions as the functionalities that can provide an API. Concepts on how to extend and modify existing controls that interact through events with other controls, overlooking that new control as a part of a custom user controls library widely publicized. User controls are something that not only have a functional part, but also have a visual part, and various functional definitions of typical management software, since that they have to control events, visualizations while these events are given and not functional of performance optimization requirements, etc ... For the study case the development platform .Net Framework is taken as tool, in all its versions, considering that control to extend is the ListView control and make it editable. This control is present in all versions of .NET framework and with a high degree of reuse. This extension also shows how you can easily migrate these extensions on all frameworks. The used development environments are several versions of Visual Studio to show that compatibility, although the development that accompanies this document is done on Visual Studio 2013.
Resumo:
El vidrio se trata de un material muy apreciado en la arquitectura debido a la transparencia, característica que pocos materiales tienen. Pero, también es un material frágil, con una rotura inmediata cuando alcanza su límite elástico, sin disponer de un período plástico, que advierta de su futura rotura y permita un margen de seguridad. Por ambas razones, el vidrio se ha utilizado en arquitectura como elemento de plementería o relleno, desde tiempos antiguos, pero no como elemento estructural o portante, pese a que es un material interesante para los arquitectos para ese uso, por su característica de transparencia, ya que conseguiría la desmaterialización visual de la estructura, logrando espacios más ligeros y livianos. En cambio, si se tienen en cuenta las propiedades mecánicas del material se puede comprobar que dispone de unas características apropiadas para su uso estructural, ya que su Módulo elástico es similar al del aluminio, elemento muy utilizado en la arquitectura principalmente en las fachadas desde los últimos años, y su resistencia a compresión es muy superior incluso al hormigón armado; aunque su principal problema es su resistencia a tracción que es muy inferior a su resistencia a compresión, lo que penaliza su resistencia a flexión. En la actualidad se empieza a utilizar el vidrio como elemento portante o estructural, pero debido a su peor resistencia a flexión, se utilizan con grandes dimensiones que, a pesar de su transparencia, tienen una gran presencia. Por ello, la presente investigación pretende conseguir una reducción de las secciones de estos elementos estructurales de vidrio. Entonces, para el desarrollo de la investigación es necesario responder a una serie de preguntas fundamentales, cuyas respuestas serán el cuerpo de la investigación: 1. ¿Cuál es la finalidad de la investigación? El objetivo de esta investigación es la optimización de elementos estructurales de vidrio para su utilización en arquitectura. 2. ¿Cómo se va a realizar esa optimización? ¿Qué sistemas se van a utilizar? El sistema para realizar la optimización será la pretensión de los elementos estructurales de vidrio 3. ¿Por qué se va a utilizar la precompresión? Porque el vidrio tiene un buen comportamiento a compresión y un mal comportamiento a tracción lo que penaliza su utilización a flexión. Por medio de la precompresión se puede incrementar esta resistencia a tracción, ya que los primeros esfuerzos reducirán la compresión inicial hasta comenzar a funcionar a tracción, y por tanto aumentará su capacidad de carga. 4. ¿Con qué medios se va a comprobar y justificar ese comportamiento? Mediante simulaciones informáticas con programas de elementos finitos. 5. ¿Por qué se utilizará este método? Porque es una herramienta que arroja ventajas sobre otros métodos como los experimentales, debido a su fiabilidad, economía, rapidez y facilidad para establecer distintos casos. 6. ¿Cómo se garantiza su fiabilidad? Mediante el contraste de resultados obtenidos con ensayos físicos realizados, garantizando de ésta manera el buen comportamiento de los programas utilizados. El presente estudio tratará de responder a todas estas preguntas, para concluir y conseguir elementos estructurales de vidrio con secciones más reducidas gracias a la introducción de la precompresión, todo ello a través de las simulaciones informáticas por medio de elementos finitos. Dentro de estas simulaciones, también se realizarán comprobaciones y comparaciones entre distintas tipologías de programas para comprobar y contrastar los resultados obtenidos, intentando analizar cuál de ellos es el más idóneo para la simulación de elementos estructurales de vidrio. ABSTRACT Glass is a material very appreciated in architecture due to its transparency, feature that just a few materials share. But it is also a brittle material with an immediate breakage when it reaches its elastic limit, without having a plastic period that provides warning of future breakage allowing a safety period. For both reasons, glass has been used in architecture as infill panels, from old times. However, it has never been used as a structural or load‐bearing element, although it is an interesting material for architects for that use: because of its transparency, structural glass makes possible the visual dematerialization of the structure, achieving lighter spaces. However, taking into account the mechanical properties of the material, it is possible to check that it has appropriate conditions for structural use: its elastic modulus is similar to that of aluminium, element widely used in architecture, especially in facades from recent years; and its compressive strength is much higher than even the one of concrete. However, its main problem consists in its tensile strength that is much lower than its compressive strength, penalizing its resistance to bending. Nowadays glass is starting to be used as a bearing or structural element, but due to its worse bending strength, elements with large dimensions must be used, with a large presence despite its transparency. Therefore this research aims to get smaller sections of these structural glass elements. For the development of this thesis, it is necessary to answer a number of fundamental questions. The answers will be the core of this work: 1. What is the purpose of the investigation? The objective of this research is the optimization of structural glass elements for its use in architecture. 2. How are you going to perform this optimization? What systems will be implemented? The system for optimization is the pre‐stress of the structural elements of glass 3. Why are you going to use the pre‐compression? Because glass has a good resistance to compression and a poor tensile behaviour, which penalizes its use in bending elements. Through the pre‐compression it is possible to increase this tensile strength, due to the initial tensile efforts reducing the pre‐stress and increasing its load capacity. 4. What are the means that you will use in order to verify and justify this behaviour? The means are based on computer simulations with finite element programs (FEM) 5. Why do you use this method? Because it is a tool which gives advantages over other methods such as experimental: its reliability, economy, quick and easy to set different cases. 6. How the reliability is guaranteed? It’s guaranteed comparing the results of the simulation with the performed physical tests, ensuring the good performance of the software. This thesis will attempt to answer all these questions, to obtain glass structural elements with smaller sections thanks to the introduction of the pre‐compression, all through computer simulations using finite elements methods. In these simulations, tests and comparisons between different types of programs will also be implemented, in order to test and compare the obtained results, trying to analyse which one is the most suitable for the simulation of structural glass elements.
Resumo:
Although context could be exploited to improve the performance, elasticity and adaptation in most distributed systems that adopt the publish/subscribe (P/S) model of communication, only very few works have explored domains with highly dynamic context, whereas most adopted models are context agnostic. In this paper, we present the key design principles underlying a novel context-aware content-based P/S (CA-CBPS) model of communication, where the context is explicitly managed, focusing on the minimization of network overhead in domains with recurrent context changes thanks to contextual scoping. We highlight how we dealt with the main shortcomings of most of the current approaches. Our research is some of the first to study the problem of explicitly introducing context-awareness into the P/S model to capitalize on contextual information. The envisioned CA-CBPS middleware enables the cloud ecosystem of services to communicate very efficiently, in a decoupled, but contextually scoped fashion.
Resumo:
This study focuses on the effectiveness of resilient wheels in reducing railway noise and vibrations, and compares the effectiveness of three types of wheels. The finite elements method has been used to characterise the vibratory behaviour of these wheels. The model has been excited with a realistic spectrum of vertical track irregularities, and a spectral analysis has been carried out. Results have been post-processed in order to estimate the sound power emitted. These calculations have been used to assess the effectiveness of the resilient wheel designs in reducing noise emitted to the environment and in propagating structural vibrations.
Resumo:
Corrosion of reinforcing steel in concrete due to chloride ingress is one of the main causes of the deterioration of reinforced concrete structures. Structures most affected by such a corrosion are marine zone buildings and structures exposed to de-icing salts like highways and bridges. Such process is accompanied by an increase in volume of the corrosión products on the rebarsconcrete interface. Depending on the level of oxidation, iron can expand as much as six times its original volume. This increase in volume exerts tensile stresses in the surrounding concrete which result in cracking and spalling of the concrete cover if the concrete tensile strength is exceeded. The mechanism by which steel embedded in concrete corrodes in presence of chloride is the local breakdown of the passive layer formed in the highly alkaline condition of the concrete. It is assumed that corrosion initiates when a critical chloride content reaches the rebar surface. The mathematical formulation idealized the corrosion sequence as a two-stage process: an initiation stage, during which chloride ions penetrate to the reinforcing steel surface and depassivate it, and a propagation stage, in which active corrosion takes place until cracking of the concrete cover has occurred. The aim of this research is to develop computer tools to evaluate the duration of the service life of reinforced concrete structures, considering both the initiation and propagation periods. Such tools must offer a friendly interface to facilitate its use by the researchers even though their background is not in numerical simulation. For the evaluation of the initiation period different tools have been developed: Program TavProbabilidade: provides means to carry out a probability analysis of a chloride ingress model. Such a tool is necessary due to the lack of data and general uncertainties associated with the phenomenon of the chloride diffusion. It differs from the deterministic approach because it computes not just a chloride profile at a certain age, but a range of chloride profiles for each probability or occurrence. Program TavProbabilidade_Fiabilidade: carries out reliability analyses of the initiation period. It takes into account the critical value of the chloride concentration on the steel that causes breakdown of the passive layer and the beginning of the propagation stage. It differs from the deterministic analysis in that it does not predict if the corrosion is going to begin or not, but to quantifies the probability of corrosion initiation. Program TavDif_1D: was created to do a one dimension deterministic analysis of the chloride diffusion process by the finite element method (FEM) which numerically solves Fick’second Law. Despite of the different FEM solver already developed in one dimension, the decision to create a new code (TavDif_1D) was taken because of the need to have a solver with friendly interface for pre- and post-process according to the need of IETCC. An innovative tool was also developed with a systematic method devised to compare the ability of the different 1D models to predict the actual evolution of chloride ingress based on experimental measurements, and also to quantify the degree of agreement of the models with each others. For the evaluation of the entire service life of the structure: a computer program has been developed using finite elements method to do the coupling of both service life periods: initiation and propagation. The program for 2D (TavDif_2D) allows the complementary use of two external programs in a unique friendly interface: • GMSH - an finite element mesh generator and post-processing viewer • OOFEM – a finite element solver. This program (TavDif_2D) is responsible to decide in each time step when and where to start applying the boundary conditions of fracture mechanics module in function of the amount of chloride concentration and corrosion parameters (Icorr, etc). This program is also responsible to verify the presence and the degree of fracture in each element to send the Information of diffusion coefficient variation with the crack width. • GMSH - an finite element mesh generator and post-processing viewer • OOFEM – a finite element solver. The advantages of the FEM with the interface provided by the tool are: • the flexibility to input the data such as material property and boundary conditions as time dependent function. • the flexibility to predict the chloride concentration profile for different geometries. • the possibility to couple chloride diffusion (initiation stage) with chemical and mechanical behavior (propagation stage). The OOFEM code had to be modified to accept temperature, humidity and the time dependent values for the material properties, which is necessary to adequately describe the environmental variations. A 3-D simulation has been performed to simulate the behavior of the beam on both, action of the external load and the internal load caused by the corrosion products, using elements of imbedded fracture in order to plot the curve of the deflection of the central region of the beam versus the external load to compare with the experimental data.
Estructuras de hormigón armado bajo carga dinámica severa. Parte III: ejemplo de simulación numérica
Resumo:
Publicamos la tercera parte y última de este artículo sobre estructuras de hormigón armado bajo carga dinámica severa en el que, los autores, nos han ido exponiendo diferentes ejemplos. En esta ocasión, se pone patente que con el desarrollo de los ordenadores durante las últimas décadas se ha dado la posibilidad de utilizar el método de los elementos finitos (FEM: Finite Elements Method) para estudiar los efectos de una carga dinámica severa, como en el caso de las explosiones. A continuación se describe el uso del método para este tipo de situaciones de carga.
Resumo:
The objective of this paper is to analyse the influence of the variation of some parameters used in the analysis of the dynamic response of offshore structures under the action of wind generated waves. The structural response has been obtained by stochastic methods using two discretization models. One with lumped parameters, using translational degrees of freedom (d.o.f.) and the other with one-dimensional finite elements. Using each of these methods the problem has been solved with several d.o.f., analysing the influence of the number of d.o.f. on the results.