63 resultados para CFRP bars
Resumo:
In order to achieve total selectivity at electrical distribution networks it is of great importance to analyze the defect currents at ungrounded power systems. This information will help to grant selectivity at electrical distribution networks ensuring that only the defect line or feeder is removed from service. In the present work a new selective and directional protection method for ungrounded power systems is evaluated. The new method measures only defect currents to detect earth faults and works with a directional criterion to determine the line under faulty conditions. The main contribution of this new technique is that it can detect earth faults in outgoing lines at any type of substation avoiding the possible mismatch of traditional directional earth fault relays. This detection technique is based on the comparison of the direction of a reference current to the direction of all earth fault capacitive currents at all the feeders connected to the same bus bars. This new method has been validated through computer simulations. The results for the different cases studied are remarkable, proving total validity and usefulness of the new method.
Resumo:
A fully integrated on-board electronic system that can perform in-situ structural health monitoring (SHM) of aircraft?s structures using specifically designed equipment for SHM based on guided wave ultrasonic method or Lamb waves? method is introduced. This equipment is called Phased Array Monitoring for Enhanced Life Assessment (PAMELA III) and is an essential part of overall PAMELA SHM? system. PAMELA III can generate any kind of excitation signals, acquire the response signals that propagate throughout the structure being tested, and perform the signal processing for damage detection directly on the structure without need to send the huge amount of raw signals but only the final SHM maps. It monitors the structure by means of an array of integrated Phased Array (PhA) transducers preferably bonded onto the host structure. The PAMELA III hardware for SHM mapping has been designed, built and subjected to laboratory tests, using aluminum and CFRP structures. The 12 channel system has been designed to be low weight (265 grams only), to have a small form factor, to be directly mounted above the integrated PhA transducers without need for cables and to be EMI protected so that the equipment can be taken on board an aircraft to perform required SHM analyses by use of embedded SHM algorithms. Moreover, the autonomous, automatic and on real-time working procedure makes it suitable for the avionic field, sending the corresponding alerts, maps and reports to external equipment.
Resumo:
La fractura de metales dúctiles como el acero suele explicarse a partir de la hipótesis de nucleación, crecimiento y coalescencia de microhuecos. A partir de esta teoría, se han desarrollado diversos modelos numéricos, entre los que el modelo de Gurson y sus variantes son los más extendidos. Dichos modelos reproducen matemáticamente el fenómeno físico de crecimiento de huecos resultando en un desarrollo progresivo del daño en el interior del material durante un ensayo de tracción. En estos modelos, el daño comienza a desarrollarse en fases muy tempranas del ensayo, incluso anteriores a la carga máxima. Ensayos realizados por los autores parecen indicar, sin embargo, que en el caso de barras de acero eutéctico empleado en la fabricación de alambres de pretensado, el daño originado en el interior del material como consecuencia del crecimiento de microhuecos sólo es apreciable en un estado muy avanzado del ensayo, momentos antes de producirse la rotura. Además, desde hace décadas se conoce que la triaxialidad de tensiones tiene una fuerte influencia sobre la rotura de los materiales. En este trabajo se presenta un modelo de rotura para elementos de acero sometidos a tracción, basado en un comportamiento cohesivo del material y que contempla el valor de la triaxialidad de tensiones, diferente en cada punto de la sección crítica de rotura. The fracture of ductile materials, such as steel, is usually explained with the theory of nucleation, growth and coalescence of microvoids. Based on this theory, many numerical models have been developed, with a special mention to Gurson-type models. These models simulate mathematically the physical growth of microvoids, leading to a progressive development of the internal damage that takes place during a tensile test. In these models, the damage starts to develop in very early stages of the test. Tests carried out by the authors seem to point out that, in the case of eutectoid steel bars used for manufacturing prestressing steel wires, the internal damage that takes place as a result of the growth of microvoids is only noticeable in a very advanced state of the test. In addition to this, it is known that the stress triaxiality has a strong influence over the fracture of ductile materials. This work presents a fracture model for steel specimens in a tensile test, based on a cohesive behaviour and taking into account the effect of stress triaxiality, which is different in every point of the fracture plane.
Resumo:
Since the epoch-making "memoir" of Saint-Venant in 1855 the torsion of prismatic and cilindrical bars has reduced to a mathematical problem: the calculation of an analytical function satisfying prescribed boundary values. For over one century, till the first applications of the F.E.M. to the problem, the only possibility of study in irregularly shaped domains was the beatiful, but limitated, theory of complex function analysis, several functional approaches and the finite difference method. Nevertheless in 1963 Jaswon published an interestingpaper which was nearly lost between the splendid F. E.M. boom. The method was extended by Rizzo to more complicated problems and definitively incorporated to the scientific community background through several lecture-notes of Cruse recently published, but widely circulated during past years. The work of several researches has shown the tremendous possibilities of the method which is today a recognized alternative to the well established F .E. procedure. In fact, the first comprehensive attempt to cover the method, has been recently published in textbook form. This paper is a contribution to the implementation of a difficulty which arises if the isoparametric elements concept is applicated to plane potential problems with sharp corners in the boundary domain. In previous works, these problems was avoided using two principal approximations: equating the fluxes round the corner or establishing a binode element (in fact, truncating the corner). The first approximation distortes heavily the solution in thecorner neighbourhood, and a great amount of element is neccesary to reduce its influence. The second is better suited but the price payed is increasing the size of the system of equations to be solved. In this paper an alternative formulation, consistent with the shape function chosen in the isoparametric representation, is presented. For ease of comprehension the formulation has been limited to the linear element. Nevertheless its extension to more refined elements is straight forward. Also a direct procedure for the assembling of the equations is presented in an attempt to reduce the in-core computer requirements.
Resumo:
La artroplastia de cadera se considera uno de los mayores avances quirúrgicos de la Medicina. La aplicación de esta técnica de Traumatología se ha incrementado notablemente en los últimos anos, a causa principalmente del progresivo incremento de la esperanza de vida. En efecto, con la edad aumentan los problemas de artrosis y osteoporosis, enfermedades típicas de las articulaciones y de los huesos que requieren en muchos casos la sustitución protésica total o parcial de la articulación. El buen comportamiento funcional de una prótesis depende en gran medida de la estabilidad primaria, es decir, el correcto anclaje de la prótesis en el momento de su implantación. Las prótesis no cementadas basan su éxito a largo plazo en la osteointegración que tiene lugar entre el material protésico y el tejido óseo, y para lograrla es imprescindible conseguir unas buenas condiciones de estabilidad primaria. El aflojamiento aséptico es la principal causa de fallo de artroplastia total de cadera. Este es un fenómeno en el que, debido a complejas interacciones de factores mecánicos y biológicos, se producen movimientos relativos que comprometen la funcionalidad del implante. La minimización de los correspondientes danos depende en gran medida de la detección precoz del aflojamiento. Para lograr la detección temprana del aflojamiento aséptico del vástago femoral se han ensayado diferentes técnicas, tanto in vivo como in vitro: análisis numéricos y técnicas experimentales basadas en sensores de movimientos provocados por cargas transmitidas natural o artificialmente, tales como impactos o vibraciones de distintas frecuencias. Los montajes y procedimientos aplicados son heterogéneos y, en muchas ocasiones, complejos y costosos, no existiendo acuerdo sobre una técnica simple y eficaz de aplicación general. Asimismo, en la normativa vigente que regula las condiciones que debe cumplir una prótesis previamente a su comercialización, no hay ningún apartado referido específicamente a la evaluación de la bondad del diseño del vástago femoral con respecto a la estabilidad primaria. El objetivo de esta tesis es desarrollar una metodología para el análisis, in vitro, de la estabilidad de un vástago femoral implantado, a fin de poder evaluar las técnicas de implantación y los diferentes diseños de prótesis previamente a su oferta en el mercado. Además se plantea como requisito fundamental que el método desarrollado sea sencillo, reversible, repetible, no destructivo, con control riguroso de parámetros (condiciones de contorno de cargas y desplazamientos) y con un sistema de registro e interpretación de resultados rápido, fiable y asequible. Como paso previo, se ha realizado un análisis cualitativo del problema de contacto en la interfaz hueso-vástago aplicando una técnica optomecánica del campo continuo (fotoelasticidad). Para ello se han fabricado tres modelos en 2D del conjunto hueso-vástago, simulando tres tipos de contactos en la interfaz: contacto sin adherencia y con holgura, contacto sin adherencia y sin holgura, y contacto con adherencia y homogéneo. Aplicando la misma carga a cada modelo, y empleando la técnica de congelación de tensiones, se han visualizado los correspondientes estados tensionales, siendo estos más severos en el modelo de unión sin adherencia, como cabía esperar. En todo caso, los resultados son ilustrativos de la complejidad del problema de contacto y confirman la conveniencia y necesidad de la vía experimental para el estudio del problema. Seguidamente se ha planteado un ensayo dinámico de oscilaciones libres con instrumentación de sensores resistivos tipo galga extensométrica. Las muestras de ensayo han sido huesos fémur en todas sus posibles variantes: modelos simplificados, hueso sintético normalizado y hueso de cadáver, seco y fresco. Se ha diseñado un sistema de empotramiento del extremo distal de la muestra (fémur) con control riguroso de las condiciones de anclaje. La oscilación libre de la muestra se ha obtenido mediante la liberación instantánea de una carga estética determinada y aplicada previamente, bien con una maquina de ensayo o bien por gravedad. Cada muestra se ha instrumentado con galgas extensométricas convencionales cuya señal se ha registrado con un equipo dinámico comercial. Se ha aplicado un procedimiento de tratamiento de señal para acotar, filtrar y presentar las respuestas de los sensores en el dominio del tiempo y de la frecuencia. La interpretación de resultados es de tipo comparativo: se aplica el ensayo a una muestra de fémur Intacto que se toma de referencia, y a continuación se repite el ensayo sobre la misma muestra con una prótesis implantada; la comparación de resultados permite establecer conclusiones inmediatas sobre los efectos de la implantación de la prótesis. La implantación ha sido realizada por un cirujano traumatólogo utilizando las mismas técnicas e instrumental empleadas en el quirófano durante la práctica clínica real, y se ha trabajado con tres vástagos femorales comerciales. Con los resultados en el dominio del tiempo y de la frecuencia de las distintas aplicaciones se han establecido conclusiones sobre los siguientes aspectos: Viabilidad de los distintos tipos de muestras sintéticas: modelos simplificados y fémur sintético normalizado. Repetibilidad, linealidad y reversibilidad del ensayo. Congruencia de resultados con los valores teóricos deducidos de la teoría de oscilaciones libres de barras. Efectos de la implantación de tallos femorales en la amplitud de las oscilaciones, amortiguamiento y frecuencias de oscilación. Detección de armónicos asociados a la micromovilidad. La metodología se ha demostrado apta para ser incorporada a la normativa de prótesis, es de aplicación universal y abre vías para el análisis de la detección y caracterización de la micromovilidad de una prótesis frente a las cargas de servicio. ABSTRACT Total hip arthroplasty is considered as one of the greatest surgical advances in medicine. The application of this technique on Traumatology has increased significantly in recent years, mainly due to the progressive increase in life expectancy. In fact, advanced age increases osteoarthritis and osteoporosis problems, which are typical diseases of joints and bones, and in many cases require full or partial prosthetic replacement on the joint. Right functional behavior of prosthesis is highly dependent on the primary stability; this means it depends on the correct anchoring of the prosthesis at the time of implantation. Uncemented prosthesis base their long-term success on the quality of osseointegration that takes place between the prosthetic material and bone tissue, and to achieve this good primary stability conditions is mandatory. Aseptic loosening is the main cause of failure in total hip arthroplasty. This is a phenomenon in which relative movements occur, due to complex interactions of mechanical and biological factors, and these micromovements put the implant functionality at risk. To minimize possible damage, it greatly depends on the early detection of loosening. For this purpose, various techniques have been tested both in vivo and in vitro: numerical analysis and experimental techniques based on sensors for movements caused by naturally or artificially transmitted loads, such as impacts or vibrations at different frequencies. The assemblies and methods applied are heterogeneous and, in many cases, they are complex and expensive, with no agreement on the use of a simple and effective technique for general purposes. Likewise, in current regulations for governing the conditions to be fulfilled by the prosthesis before going to market, there is no specific section related to the evaluation of the femoral stem design in relation to primary stability. The aim of this thesis is to develop a in vitro methodology for analyzing the stability of an implanted femoral stem, in order to assess the implantation techniques and the different prosthesis designs prior to its offer in the market. We also propose as a fundamental requirement that the developed testing method should be simple, reversible, repeatable, non-destructive, with close monitoring of parameters (boundary conditions of loads and displacements) and with the availability of a register system to record and interpret results in a fast, reliable and affordable manner. As a preliminary step, we have performed a qualitative analysis of the contact problems in the bone-stem interface, through the application of a continuous field optomechanical technique (photoelasticity). For this proposal three 2D models of bone–stem set, has been built simulating three interface contact types: loosened an unbounded contact, unbounded and fixed contact, and bounded homogeneous contact. By means of applying the same load to each model, and using the stress freezing technique, it has displayed the corresponding stress states, being more severe as expected, in the unbounded union model. In any case, the results clearly show the complexity of the interface contact problem, and they confirm the need for experimental studies about this problem. Afterward a free oscillation dynamic test has been done using resistive strain gauge sensors. Test samples have been femur bones in all possible variants: simplified models, standardized synthetic bone, and dry and cool cadaveric bones. An embedding system at the distal end of the sample with strong control of the anchoring conditions has been designed. The free oscillation of the sample has been obtained by the instantaneous release of a static load, which was previously determined and applied to the sample through a testing machine or using the gravity force. Each sample was equipped with conventional strain gauges whose signal is registered with a marketed dynamic equipment. Then, it has applied a signal processing procedure to delimit, filter and present the time and frequency response signals from the sensors. Results are interpreted by comparing different trials: the test is applied to an intact femur sample which is taken as a reference, and then this test is repeated over the same sample with an implanted prosthesis. From comparison between results, immediate conclusions about the effects of the implantation of the prosthesis can be obtained. It must be said that the implementation has been made by an expert orthopedic surgeon using the same techniques and instruments as those used in clinical surgery. He has worked with three commercial femoral stems. From the results obtained in the time and frequency domains for the different applications the following conclusions have been established: Feasibility of the different types of synthetic samples: simplified models and standardized synthetic femur. Repeatability, linearity and reversibility of the testing method. Consistency of results with theoretical values deduced from the bars free oscillations theory. Effects of introduction of femoral stems in the amplitude, damping and frequencies of oscillations Detection of micromobility associated harmonics. This methodology has been proved suitable to be included in the standardization process of arthroplasty prosthesis, it is universally applicable and it allows establishing new methods for the analysis, detection and characterization of prosthesis micromobility due to functional loads.
Condicionantes de la adherencia y anclaje en el refuerzo de muros de fábrica con elementos de fibras
Resumo:
Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.
Resumo:
Cracking of reinforced concrete can occur in certain environments due to rebar corrosion. The oxide layer growing around the bars introduces a pressure which may be enough to lead to the fracture of concrete. To study such an effect, the results of accelerated corrosion tests and finite ele- ment simulations are combined in this work. In previous works, a numerical model for the expansive layer, called expansive joint element , was programmed by the authors to reproduce the effect of the oxide over the concrete. In that model, the expansion of the oxide layer in stress free conditions is simulated as an uniform expansion perpendicular to the steel surface. The cracking of concrete is simulated by means of finite elements with an embedded adaptable cohesive crack that follow the standard cohesive model. In the present work, further accelerated tests with imposed constant cur- rent have been carried out on the same type of specimens tested in previous works (with an embedded steel tube), while measuring, among other things, the main-crack mouth opening. Then, the tests have been numerically simulated using the expansive joint element and the tube as the corroding electrode (rather than a bar). As a result of the comparison of numerical and experimental results, both for the crack mouth opening and the crack pattern, new insight is gained into the behavior of the oxide layer. In particular, quantitative assessment of the oxide expansion relation is deduced from the ex- periments, and a narrower interval for the shear stiffness of the oxide layer is obtained, which could not be achieved using bars as the corroding element, because in that case the numerical results were insensitive to the shear stiffness of the oxide layer within many orders of magnitude
Resumo:
One of the most important design constraints of a climbing robot is its own weight. When links or legs are used as a locomotion system they tend to be composed of special lightweight materials, or four-bars-linkage mechanisms are designed to reduce the weight with small rigidity looses. In these cases, flexibility appears and undesirable effects, such as dynamics vibrations, must be avoided at least when the robot moves at low speeds. The knowledge of the real tip position requires the computation of its compliance or stiffness matrix and the external forces applied to the structure. Gravitational forces can be estimated, but external tip forces need to be measured. This paper proposes a strain gauge system which achieves the following tasks: (i) measurement of the external tip forces, and (ii) estimation of the real tip position (including flexibility effects). The main advantages of the proposed system are: (a) the use of external force sensors is avoided, and (b) a substantial reduction of the robot weight is achieved in comparison with other external force measurement systems. The proposed method is applied to a real symmetric climbing robot and experimental results are presented.
Resumo:
A través de los años las estructuras de hormigón armado han ido aumentando su cuota de mercado, sustituyendo a las estructuras de fábrica de piedra o ladrillo y restándole participación a las estructuras metálicas. Uno de los primeros problemas que surgieron al ejecutar las estructuras de hormigón armado, era cómo conectar una fase de una estructura de este tipo a una fase posterior o a una modificación posterior. Hasta los años 80-90 las conexiones de una fase de una estructura de hormigón armado, con otra posterior se hacían dejando en la primera fase placas de acero con garrotas embebidas en el hormigón fresco o barras grifadas recubiertas de poliestireno expandido. Una vez endurecido el hormigón se podían conectar nuevas barras, para la siguiente fase mediante soldadura a la placa de la superficie o enderezando las barras grifadas, para embeberlas en el hormigón fresco de la fase siguiente. Estos sistemas requerían conocer la existencia y alcance de la fase posterior antes de hormigonar la fase previa. Además requerían un replanteo muy exacto y complejo de los elementos de conexión. Otro problema existente en las estructuras de hormigón era la adherencia de un hormigón fresco a un hormigón endurecido previamente, ya que la superficie de contacto de ambos hormigones suponía un punto débil, con una adherencia baja. A partir de los años 80, la industria química de la construcción experimentó un gran avance en el desarrollo de productos capaces de generar una buena adherencia sobre el hormigón endurecido. Este avance tecnológico tenía aplicación tanto en la adherencia del hormigón fresco sobre el hormigón endurecido, como en la adherencia de barras post-instaladas en agujeros de hormigón endurecido. Este sistema se denominó “anclajes adherentes de barras de acero en hormigón endurecido”. La forma genérica de ejecutarlos es hacer una perforación cilíndrica en el soporte de hormigón, con una herramienta especifica como un taladro, limpiar la perforación, llenarla del material adherente y finalmente introducir la barra de acero. Los anclajes adherentes se dividen en anclajes cementosos y anclajes químicos, siendo estos últimos los más habituales, fiables, resistentes y fáciles de ejecutar. El uso del anclaje adherente de barras de acero en hormigón endurecido se ha extendido por todo el espectro productivo, siendo muy habitual tanto en construcción de obras de hormigón armado de obra civil y edificación, como en obras industriales, instalaciones o fijación de elementos. La ejecución de un anclaje de una barra de acero en hormigón endurecido depende de numerosas variables, que en su conjunto, o de forma aislada pueden afectar de forma notable a la resistencia del anclaje. Nos referimos a variables de los anclajes, que a menudo no se consideran tales como la dirección de la perforación, la máquina de perforación y el útil de perforación utilizado, la diferencia de diámetros entre el diámetro del taladro y la barra, el tipo de material de anclaje, la limpieza del taladro, la humedad del soporte, la altura del taladro, etc. La utilización en los últimos años de los hormigones Autocompactables, añade una variable adicional, que hasta ahora apenas ha sido estudiada. En línea con lo apuntado, la presente tesis doctoral tiene como objetivo principal el estudio de las condiciones de ejecución en la resistencia de los anclajes en hormigón convencional y autocompactable. Esta investigación se centra principalmente en la evaluación de la influencia de una serie de variables sobre la resistencia de los anclajes, tanto en hormigón convencional como en un hormigón autocompactable. Para este estudio ha sido necesaria la fabricación de dos soportes de hormigón sobre los cuales desarrollar los ensayos. Uno de los bloques se ha fabricado con hormigón convencional y el otro con hormigón autocompactable. En cada pieza de hormigón se han realizado 174 anclajes con barras de acero, variando los parámetros a estudiar, para obtener resultados de todas las variables consideradas. Los ensayos a realizar en ambos bloques son exactamente iguales, para poder comparar la diferencia entre un anclaje en un soporte de hormigón con vibrado convencional (HVC) y un hormigón autocompactante (HAC). De cada tipo de ensayo deseado se harán dos repeticiones en la misma pieza. El ensayo de arrancamiento de las barras se realizara con un gato hidráulico hueco, con un sistema de instrumentación de lectura y registro de datos en tiempo real. El análisis de los resultados, realizado con una potente herramienta estadística, ha permitido determinar y evaluar numéricamente la influencia de los variables consideradas en la resistencia de los anclajes realizados. Así mismo ha permitido diferenciar los resultados obtenidos en los hormigones convencionales y autocompactantes, tanto desde el punto de vista de la resistencia mecánica, como de las deformaciones sufridas en el arrancamiento. Se define la resistencia mecánica de un anclaje, como la fuerza desarrollada en la dirección de la barra, para hacer su arrancamiento del soporte. De la misma forma se considera desplazamiento, a la separación entre un punto fijo de la barra y otro del soporte, en la dirección de la barra. Dichos puntos se determinan cuando se ha terminado el anclaje, en la intersección de la superficie plana del soporte, con la barra. Las conclusiones obtenidas han permitido establecer qué variables afectan a la ejecución de los anclajes y en qué cuantía lo hacen, así como determinar la diferencia entre los anclajes en hormigón vibrado convencional y hormigón autocompactante, con resultados muy interesantes, que permiten valorar la influencia de dichas variables. Dentro de las conclusiones podemos destacar tres grupos, que denominaremos como de alta influencia, baja influencia y sin influencia. En todos los casos hay que hacer el estudio en términos de carga y de desplazamiento. Podemos considerar como de alta influencia, en términos de carga las variables de máquina de perforación y el material de anclaje. En términos de desplazamiento podemos considerar de alta influencia además de la máquina de perforación y el material de anclaje, el diámetro del taladro, así como la limpieza y humedad del soporte. Podemos considerar de baja influencia, en términos de carga las variables de tipo de hormigón, dirección de perforación, limpieza y humedad del soporte. En términos de desplazamiento podemos considerar de baja influencia el tipo de hormigón y la dirección de perforación. Podemos considerar en el apartado de “sin influencia”, en términos de carga las variables de diámetro de perforación y altura del taladro. En términos de desplazamiento podemos considerar como “sin influencia” la variable de altura del taladro. Podemos afirmar que las diferencias entre los valores de carga aumentan de forma muy importante en términos de desplazamiento. ABSTRACT Over the years the concrete structures have been increasing their market share, replacing the masonry structures of stone or brick and subtracting as well the participation of the metallic structures. One of the first problems encountered in the implementing of the reinforced concrete structures was connecting a phase structure of this type at a later stage or a subsequent amendment. Until the 80s and 90s the connections of one phase of a reinforced concrete structure with a subsequent first phase were done by leaving the steel plates embedded in the fresh concrete using hooks or bent bars coated with expanded polystyrene. Once the concrete had hardened new bars could be connected to the next stage by welding them to the surface plate or by straightening the bent bars to embed them in the fresh concrete of the next phase. These systems required a previous knowledge of the existence and scope of the subsequent phase before concreting the previous one. They also required a very precise and complex rethinking of the connecting elements. Another existing problem in the concrete structures was the adhesion of a fresh concrete to a previously hardened concrete, since the contact surface of both concretes leaded to a weak point with low adherence. Since the 80s, the chemicals construction industry experienced a breakthrough in the development of products that generate a good grip on the concrete. This technological advance had its application both in the grip on one hardened fresh concrete and in the adhesion of bar post-installed in holes of hardened concrete. This system was termed as adherent anchors of steel bars in hardened concrete. The generic way of executing this system is by firstly drilling a cylindrical hole in the concrete support using a specific tool such as a drill. Then, cleaning the bore and filling it with bonding material to lastly, introduce the steel bar. These adherent anchors are divided into cement and chemical anchors, the latter being the most common, reliable, durable and easy to run. The use of adhesive anchor of steel bars in hardened concrete has spread across the production spectrum turning itself into a very common solution in both construction of reinforced concrete civil engineering and construction, and industrial works, installations and fixing elements as well. The execution of an anchor of a steel bar in hardened concrete depends on numerous variables which together or as a single solution may significantly affect the strength of the anchor. We are referring to variables of anchors which are often not considered, such as the diameter difference between the rod and the bore, the drilling system, cleansing of the drill, type of anchor material, the moisture of the substrate, the direction of the drill, the drill’s height, etc. During recent years, the emergence of self-compacting concrete adds an additional variable which has hardly been studied so far. According to mentioned this thesis aims to study the main performance conditions in the resistance of conventional and self-compacting concrete anchors. This research is primarily focused on the evaluation of the influence of several variables on the strength of the anchoring, both in conventional concrete and self-compacting concrete. In order to complete this study it has been required the manufacture of two concrete supports on which to develop the tests. One of the blocks has been manufactured with conventional concrete and the other with self-compacting concrete. A total of 174 steel bar anchors have been made in each one of the concrete pieces varying the studied parameters in order to obtain results for all variables considered. The tests to be performed on both blocks are exactly the same in order to compare the difference between an anchor on a stand with vibrated concrete (HVC) and a self-compacting concrete (SCC). Each type of test required two repetitions in the same piece. The pulling test of the bars was made with a hollow jack and with an instrumentation system for reading and recording data in real time. The use of a powerful statistical tool in the analysis of the results allowed to numerically determine and evaluate the influence of the variables considered in the resistance of the anchors made. It has likewise enabled to differentiate the results obtained in the self-compacting and conventional concretes, from both the outlook of the mechanical strength and the deformations undergone by uprooting. The mechanical strength of an anchor is defined as the strength undergone in a direction of the bar to uproot it from the support. Likewise, the movement is defined as the separation between a fixed point of the bar and a fixed point from the support considering the direction of the bar. These points are only determined once the anchor is finished, with the bar, at the intersection in the flat surface of the support. The conclusions obtained have established which variables affect the execution of the anchors and in what quantity. They have also permitted to determine the difference between the anchors in vibrated concrete and selfcompacting concrete with very interesting results that also allow to assess the influence of these mentioned variables. Three groups are highlighted among the conclusions called high influence, low influence and no influence. In every case is necessary to perform the study in terms of loading and movement. In terms of loading, there are considered as high influence two variables: drilling machinery and anchorage material. In terms of movement, there are considered as high influence the drilling diameter and the cleaning and moisture of the support, besides the drilling machinery and the anchorage material. Variables such as type of concrete, drilling direction and cleaning and moisture of the support are considered of low influence in terms of load. In terms of movement, the type of concrete and the direction of the drilling are considered variables of low influence. Within the no influence section in terms of loading, there are included the diameter of the drilling and the height of the drill. In terms of loading, the height of the drill is considered as a no influence variable. We can affirm that the differences among the loading values increase significantly in terms of movement.
Resumo:
Las probetas cilíndricas fabricadas con materiales metálicos de elevada ductilidad, como el aluminio o el cobre, sometidas a tracción suelen presentar una rotura comúnmente denominada rotura en copa y cono, debido a su geometría. Este tipo de rotura se reproduce numéricamente con éxito mediante el modelo de Gurson-Tvergaard- Needleman, cuya formulación matemática se basa en el fenómeno físico de nucleación, crecimiento y coalescencia de microhuecos. A diferencia de dichos materiales, las barras de acero perlítico, material con una ductilidad apreciable, presentan un frente de rotura plano que no puede simularse correctamente con los modelos antes mencionados, apareciendo una región interior de daño que, en principio, también puede atribuirse a un fenómeno de nucleación y crecimiento de microhuecos, mientras que en el exterior aparece una zona cuya micrografía permite asociar su rotura a un mecanismo de clivaje. En trabajos anteriores los autores han presentado un elemento de intercara cohesivo dependiente de la triaxialidad de tensiones que, incorporado a un código de elementos finitos, permite reproducir de forma razonable el daño que se desarrolla en la región interior mencionada. En este trabajo se presentan los resultados de una campaña experimental que permite validar el modelo desarrollado. Para ello, se ensayan probetas de diferentes diámetros y se comparan los resultados con los obtenidos numéricamente, empleando tres bases extensométricas diferentes en cada uno de los diámetros. Los resultados numéricos se ajustan razonablemente bien a los obtenidos experimentalmente.The cylindrical specimens made of high-ductility metallic materials, such as aluminium and copper, usually fail showing a fracture surface commonly known as cup-cone fracture because of its shape. This type of fracture is successfully reproduced using the Gurson-Tvergaard-Needleman model, which is based on the physical process of nucleation, growth and coalescence of microvoids. Unlike these materials, pearlitic steel bars, which are considerably ductile, show a flat fracture surface that cannot be correctly reproduced with the aforementioned models. In this flat fracture surface, a dark region can be observed in the centre of the specimen, which is the result of a process of nucleation and growth of microvoids, while in the rest of the fracture surface a different region can be identified, which a micrographic study reveals to be the result of a process of cleavage. In previous works, the authors presented a triaxiality-dependent cohesive interface element that, implemented in a finite element code, can reproduce in a reasonably accurate manner the damage that takes place in the dark region mentioned before. The results of an experimental campaign designed to validate the model are presented in this paper. For it, different diameter specimens are tested and these results are compared to those obtained with the numerical models, using three different initial lengths for the strain. Numerical results agree reasonably well with those obtained experimentally.
Resumo:
In the last years, many analyses from acoustic signal processing have been used for different applications. In most cases, these sensor systems are based on the determination of times of flight for signals from every transducer. This paper presents a flat plate generalization method for impact detection and location over linear links or bars-based structures. The use of three piezoelectric sensors allow to achieve the position and impact time while the use of additional sensors lets cover a larger area of detection and avoid wrong timing difference measurements. An experimental setup and some experimental results are briefly presented.
Resumo:
Las probetas cilíndricas fabricadas con materiales metálicos de elevada ductilidad, como el aluminio o el cobre, sometidas a tracción suelen presentar una rotura comúnmente denominada rotura en copa y cono, debido a su geometría. Este tipo de rotura se reproduce numéricamente con éxito mediante el modelo de Gurson-Tvergaard- Needleman, cuya formulación matemática se basa en el fenómeno físico de nucleación, crecimiento y coalescencia de microhuecos. A diferencia de dichos materiales, las barras de acero perlítico, material con una ductilidad apreciable, presentan un frente de rotura plano que no puede simularse correctamente con los modelos antes mencionados, apareciendo una región interior de daño que, en principio, también puede atribuirse a un fenómeno de nucleación y crecimiento de microhuecos, mientras que en el exterior aparece una zona cuya micrografía permite asociar su rotura a un mecanismo de clivaje. En trabajos anteriores los autores han presentado un elemento de intercara cohesivo dependiente de la triaxialidad de tensiones que, incorporado a un código de elementos finitos, permite reproducir de forma razonable el daño que se desarrolla en la región interior mencionada. En este trabajo se presentan los resultados de una campaña experimental que permite validar el modelo desarrollado. Para ello, se ensayan probetas de diferentes diámetros y se comparan los resultados con los obtenidos numéricamente, empleando tres bases extensométricas diferentes en cada uno de los diámetros. Los resultados numéricos se ajustan razonablemente bien a los obtenidos experimentalmente.The cylindrical specimens made of high-ductility metallic materials, such as aluminium and copper, usually fail showing a fracture surface commonly known as cup-cone fracture because of its shape. This type of fracture is successfully reproduced using the Gurson-Tvergaard-Needleman model, which is based on the physical process of nucleation, growth and coalescence of microvoids. Unlike these materials, pearlitic steel bars, which are considerably ductile, show a flat fracture surface that cannot be correctly reproduced with the aforementioned models. In this flat fracture surface, a dark region can be observed in the centre of the specimen, which is the result of a process of nucleation and growth of microvoids, while in the rest of the fracture surface a different region can be identified, which a micrographic study reveals to be the result of a process of cleavage. In previous works, the authors presented a triaxiality-dependent cohesive interface element that, implemented in a finite element code, can reproduce in a reasonably accurate manner the damage that takes place in the dark region mentioned before. The results of an experimental campaign designed to validate the model are presented in this paper. For it, different diameter specimens are tested and these results are compared to those obtained with the numerical models, using three different initial lengths for the strain. Numerical results agree reasonably well with those obtained experimentally.
Evaluación de parámetros que influyen en el transporte de cloruros en hormigón parcialmente saturado
Resumo:
El deterioro del hormigón debido a la presencia del ion cloruro es causa frecuente de problemas en estructuras localizadas en ambiente marino y alta montaña. Su principal efecto consiste en la despasivación del acero de refuerzo embebido en el hormigón y su consecuente inicio de la corrosión del mismo. El ingreso del ion cloruro al interior del hormigón, está condicionado por una serie de parámetros de origen medioambiental e intrínsecos del hormigón. En función de estos parámetros el ingreso de cloruros en el hormigón puede deberse principalmente a los siguientes mecanismos: difusión y succión capilar. El estudio y evaluación de la resistencia del hormigón frente a cloruros, se ha desarrollado principalmente en condiciones saturadas del hormigón. Lo que ha significado que parámetros de importancia no sean considerados. Debido a esto, distintos procesos que suceden en estructuras reales no han sido identificados y estudiados correctamente. En este trabajo, se diseñó un programa de investigación para evaluar los parámetros que influyen en el transporte cloruros en hormigones no saturados. Para esto se diseñaron tres dosificaciones diferentes de hormigón. En la primera se empleó únicamente cemento portland, para el resto se utilizaron adiciones minerales (humo de sílice y escoria de alto horno). El empleo de adiciones se debió a que tienen un papel importante en la durabilidad de hormigones frente a cloruros. Los hormigones fueron dosificados con una relación agua/material cementício de 0,40 para el hormigón elaborado únicamente con cemento portland y 0,45 para las mezclas con adiciones. Para evaluar las propiedades de los hormigones en estado fresco y endurecido se realizaron ensayos vigentes en las normativas. Con los resultados obtenidos se determinaron parámetros de resistencia mecánica, microestructurales, resistencia al transporte de cloruros e higroscópicos. Una vez caracterizados los hormigones, se diseñó una propuesta experimental para estudiar los principales parámetros presentes en estructuras reales con presencia de cloruros. Tanto la concentración de cloruro como las condiciones ambientales se han variado teniendo como referencia las situaciones reales que podrían producirse en ambientes de alta montaña en la zona centro de España. La propuesta experimental consistió en tratar de evaluar la capacidad de los hormigones al transporte de iones en ambientes de alta montaña con presencia de sales fundentes. Para esto se establecieron 5 fases experimentales donde los principales parámetros ambientales y la presencia de iones agresivos sufrieron variaciones. Al término de cada fase se obtuvieron perfiles de penetración de cloruros en los hormigones y se evaluó la influencia de los parámetros presentes en cada fase. Los resultados experimentales se implementaron en un modelo numérico basado en la teoría de elementos finitos, desarrollado por el grupo de investigación del Departamento de Materiales de Construcción. Para esto fue necesario realizar la calibración y validación del modelo numérico para cada hormigón. El calibrado del modelo precisa de datos químicos y microestructurales de cada hormigón, tales como: capacidad de combinación de cloruros y propiedades difusivas e higroscópicas. Para la validación del modelo numérico se realizaron simulaciones de la propuesta experimental. Los resultados obtenidos se compararon con los valores experimentales. Con el objeto de poder estudiar en mayor profundidad la influencia del grado de saturación del hormigón durante la difusión de cloruros, se llevó a cabo una campaña experimental que consideró distintos grados de saturación en los hormigones. Para esto se establecieron en los hormigones cuatro grados de saturación distintos (50%, 60%, 80% y 100%, aproximadamente), posteriormente se expusieron a cloruro de sodio finamente molido. Una vez transcurrido el tiempo necesario se obtuvieron experimentalmente los perfiles de penetración de cloruros para cada grado de saturación y se calcularon los coeficientes de difusión. Los datos obtenidos durante la campaña experimental han demostrado la influencia positiva que ejercen las adiciones en las mezclas de hormigón. Sus principales ventajas son el refinamiento de la red porosa y el aumento en la capacidad de combinación de cloruros, además de mejorar sus propiedades mecánicas. La porosidad total en las mezclas no presentó grandes cambios, sin embargo, el cambio en la distribución del tamaño de poros es importante en las muestras con adiciones. En especial las fabricadas con humo de sílice. Los coeficientes de difusión y migración de cloruros para las mezclas con adiciones disminuyeron significativamente, igual que los valores de resistividad eléctrica. En los ensayos de penetración del agua bajo presión, fueron las muestras con adiciones las que mostraron las menores penetraciones. Los resultados obtenidos al final de la propuesta experimental permitieron estudiar los distintos parámetros involucrados. Se observó claramente que el proceso de difusión provoca el mayor transporte de cloruros hacia el interior del hormigón. Así mismo se comprobó que el lavado superficial y el secado de las probetas, trasladan cloruros hacia las zonas externas del hormigón. El primero debido a una baja concentración de cloruros externa, mientras que el secado provoca el movimiento de la solución de poro hacia las zonas de secado depositando cloruros en ellas. Las medidas higroscópicas permitieron determinar la existencia de dos zonas distintas en el interior del hormigón. La primera se localizó en el rango de 0-10mm, aproximadamente, en ésta se puso de manifiesto una mayor sensibilidad a los cambios experimentados en el exterior de las probetas. La segunda zona se localizó a una profundidad mayor de 10mm, aproximadamente. Se observó claramente una baja influencia de los cambios externos, siendo la difusión de cloruros el principal mecanismo de transporte presente en ella. En cuanto al estudio de la influencia del grado de saturación en la difusión de cloruros, se observó claramente una marcada diferencia entre los coeficientes de difusión de cloruro obtenidos. Para grados de saturación mayores del 80% el mecanismo de penetración de cloruros por difusión existe de forma significativa. Mientras que para valores inferiores los resultados revelaron que las vías de acceso disminuyen (poros conectado con agua) considerablemente limitando en un alto grado la penetración del agresivo. Para grados de saturación inferiores del 50% los valores del coeficiente de difusión son despreciables. The deterioration of concrete due to chloride ions is a frequent problem identified in structures located in marine and high-mountain environments. After entering the outer layer of the concrete, the chlorides tend to penetrate until they reach and then depassivate the steel bars. Subsequently, this induces the deterioration process of the reinforced concrete. This chloride penetration depends on the environmental conditions and intrinsic parameters of the concrete. Several transport mechanisms, such as diffusion, capillary suction and permeability can be present into the concrete. While recent research into the study and evaluation of concretes with chloride presence has been carried out in saturated concrete, it has not considered certain parameters that can modify this condition. Consequently, at the time of writing several processes that take place in real structures have not been identified and studied. In this work a research programme is designed to evaluate the parameters that influence chloride transport into non-saturated concrete. For this, three concrete mixes were designed by using high-early-strength Portland cement and mineral admixtures (silica fume and blast-slag furnace). The water-cement ratio was 0.40 for the concrete made solely with Portland cement and 0.45 for the concretes that used mineral admixtures as a cement replacement. A set of experimental tests were performed to evaluate the concrete properties both in fresh and hardened state. In addition, an experimental simulation was carried out under laboratory conditions in which the main objective was to assess resistance of concrete to chloride penetration under high-mountain conditions with the presence of de-icing salts. The environmental conditions and surface chloride concentration of the concrete used during the experimental simulation were chosen by considering conditions found in the high-mountain environment in central Spain. For the experimental simulation five phases were designed by varying the environmental parameters and concrete surface concentration. At the end of each phase a chloride profile was obtained with the aim of assessing the influence of the parameters on chloride transport. The experimental results were then used to calibrate and validate a numerical model based on finite element theory developed by the research team from the Construction Materials Department in a previous work. In order to carry out model calibration chemical and microstructural data for the concretes was required, such as binding capacity and the diffusive and hygroscopic properties. The experimental results were compared with the numerical simulations and provided a good fit. With the objective of studying the influence of the degree of concrete saturation on chloride diffusion, an experimental programme was designed. This entailed four saturation degrees (50%, 60%, 80% and 100%) being established in several concrete samples. The samples were then exposed to ground sodium chloride. Once the time required was achieved, the chloride profiles and diffusion coefficients were obtained for each saturation degree. The results obtained from the experimental program revealed a positive influence of the mineral admixtures on the concretes. Their effects were reflected in the pore-network refinement and the increase of chloride binding capacity, together with the improvement of the mechanical properties of the concretes. Total porosity did not reveal any notable change, though the pore-size distribution showed a significant degree of change in the concretes with mineral admixtures, specifically the samples prepared through use of silica fume. The chloride diffusion and migration coefficient, as well as the electrical resistivity values, decreased significantly in the concretes with admixtures. In the water penetration under pressure test, the concretes with admixtures presented the lowest penetration depth. The results obtained in the experimental simulation allowed study of the main parameters involved during the chloride penetration processes in non-saturated concretes in the presence of chlorides. According to the results, the diffusion process was the transport mechanism that transferred the greatest amount of chlorides into the concrete samples. In addition, a chloride movement toward external zones of the concrete, caused by the washing of concrete surface and the drying processes, was identified. The washing occurred when the concrete surface came into contact with a low-chloride concentration solution which initiated the outward movement of chloride diffusion. The drying processes corresponded to a movement of pore solution launched by water evaporation from the outer layer. Furthermore, hygroscopic measurements made in the concrete allowed two areas with distinct behavioural patterns to be identified. The first one, located in the range of approximately 0-10mm, showed a greater degree of influence regarding the changes of the external conditions. The second, situated at depths greater than 10mm, displayed a low influence of external conditions. The main process in this area was diffusion. Study of the influence of the degree of concrete saturation on chloride diffusion showed a clear difference among the chloride diffusion coefficients obtained. For degrees of concrete saturation higher than 80%, chloride penetration by diffusion tends to be significant. However, in the case of extent of saturation of lower than 80%, the results revealed that the access zone through which chlorides can penetrate decreased considerably. For degrees of concrete saturation lower than 50%, the chloride diffusion coefficients were negligible.
Resumo:
Entre los requisitos que deben cumplir las estructuras se debe garantizar que estas posean la durabilidad necesaria para permanecer en servicio a lo largo de todo el periodo de vida útil para el que han sido proyectadas. Para conseguir este objetivo las normativas han ido incorporando prescripciones para el diseño del hormigón, en base a distintas clases de exposición dependiendo del origen y magnitud de la agresividad exterior. En ambientes con una elevada agresividad, una de las comprobaciones que debe cumplir el hormigón es que tenga una permeabilidad inferior a los valores máximos fijados según la clase de exposición, y que en caso de considerar como ensayo de referencia el de penetración de agua, analiza el frente de penetración limitando las profundidades de penetración media y máxima. Adicionalmente a las condiciones de diseño según el tipo de ambiente, principalmente basadas en la dosificación del hormigón en términos de la relación agua/cemento y el mínimo contenido de cemento y el recubrimiento de las armaduras, durante la vida en servicio las estructuras pueden están solicitadas por distintas acciones imprevistas que pueden provocar cambios en la microestructura interna del hormigón que modifican su permeabilidad y resistencia, y por tanto pueden alterar la durabilidad inicialmente prevista. Es conocido el efecto de cansancio del hormigón cuando está solicitado por cargas de compresión mantenidas en el tiempo, provocando bajas en su resistencia debido al incremento de la microfisuración. Dada la relación entre la permeabilidad y la microfisuración del hormigón, es previsible el aumento de la permeabilidad en hormigones que han sido precomprimidos durante un periodo largo de tiempo. Los estudios de la permeabilidad en hormigones previamente comprimidos se han realizado analizando periodos de tiempo de compresión cortos que no permiten evaluar el efecto del cansancio sobre la permeabilidad. La presente tesis doctoral investiga la permeabilidad y resistencia a tracción en hormigones que previamente han sido comprimidos en carga mantenida durante distintos plazos de tiempo, al objeto de conocer su evolución en base al tiempo de precompresión. La investigación se apoya en el estudio de otras dos variables como son el tipo de hormigón de acuerdo a su dosificación según el tipo de ambiente considerando una agresividad baja, media o alta, y el grado de compresión aplicado respecto de su carga última de rotura. En los resultados del plan experimental desarrollado se ha obtenido que la permeabilidad presenta un incremento significante con el tiempo de precompresión, que dependiendo del valor inicial de la permeabilidad que tiene el hormigón puede provocar que hormigones que previamente satisfacen las limitaciones de permeabilidad pasen a incumplirlas, pudiendo afectar a su durabilidad. También se confirma la influencia del tiempo de precompresión sobre la resistencia a tracción obteniendo bajas de resistencia importantes en los casos pésimos ensayados, que deben ser tenidas en consideración en tanto afectan a la capacidad resistente del hormigón como a otros aspectos fundamentales como el anclaje de las armaduras en el hormigón armado y pretensado. One of the requirements that structures must meet is to guarantee their durability to remain in service throughout all the working life period for which they have been designed. To achieve this goal, building standards and codes have included specifications for the design of concrete structures, based on different exposure classes depending on the environmental conditions and their origin and magnitude. In severe aggressive environments, one of the specifications the concrete must meet is to have a permeability lower than the maximum values set for a certain exposure class. If this parameter is referenced to water penetration on specimens, then the average and maximum depths of front penetration are analyzed. In addition to the design conditions depending on the exposure class, which regulate the dosage of concrete in terms of the water/cement ratio, minimum samples that have been pre-compressed for a long period of time. Previous studies on permeability have been carried on pre-compressed concrete elements analyzing short periods of time. However, they have not studied the effects of compression forces on concrete in the long term. This Thesis investigates permeability and tensile strength of concrete samples that have been previously compressed under loads applied for different periods of time. The goal is to understand its evolution based on the time exposed to compression. The research variables also include the type of concrete according to the dosage used - depending on the environmental exposure it will have low, medium or high aggressiveness-, and the amount of compression applied in relation to its failure load. Results of the experimental tests showed that permeability increases significantly over the time of pre-compression. Depending on the initial value of permeability, this change could make the concrete not meet the original permeability restrictions and therefore affect its durability. These investigations also confirmed the influence of time of pre-compression in tensile strength, where some cases showed a significant decrease of resistance. These issues must be taken into consideration as they affect the bearing capacity of the material and other key features such as the anchoring of steel bars in reinforced and pre-stressed concrete. amount of cement content and the minimum concrete cover of the steel bars, during their working life structures may be subject to various unforeseen actions. As a result, the concrete’s internal microstructure might be affected, changing its permeability and resistance, and possibly altering the original specified durability. It is a known fact that when concrete is loaded in compression maintained over a long time, its resistance to compression forces is diminished due to the increase in micro-cracking. Considering the relationship between permeability and microcracking of concrete, an increase in permeability may be expected in concrete
Resumo:
Las estructuras de hormigón son susceptibles de sufrir los efectos asociados a las acciones de fatiga cuando estas se ven sometidas a un elevado número de cargas repetidas. Muchas de estas estructuras no requieren armadura transversal para cumplir los condicionantes de dimensionamiento estático como por ejemplo las losas superiores de tableros de puentes, los muros de contención, las losas de transición de puentes, las torres eólicas o las estructuras marítimas. La mayor parte de los códigos de diseño vigentes no incluyen una comprobación específica del nivel de seguridad a cortante de estas estructuras para acciones de fatiga, y aquellas que lo hacen prefieren utilizar expresiones de tipo empírico basadas en curvas S-N que relacionan el número de ciclos resistentes con el valor de la carga aplicada. A pesar de que el empleo de curvas S-N es de gran utilidad desde un punto de vista práctico, estas curvas no permiten comprender el proceso de rotura por cortante para cargas repetidas. El objetivo principal de esta Tesis es el de estudiar el comportamiento a cortante de elementos de hormigón armado sin cercos sometidos a fatiga. Además, el análisis es ampliado al estudio del comportamiento transversal de los voladizos de las losas superiores de tableros de puentes de hormigón que de forma habitual son diseñados sin armadura de cortante. De forma habitual estos elementos se diseñan atendiendo a criterios de dimensionamiento estáticos sin tener en cuenta la resistencia a cortante cuando se ven sometidos a cargas cíclicas. A pesar de que las cargas de fatiga son inferiores a aquellas que producen el fallo estático, es importante tener en cuenta el comportamiento de estos elementos ante cargas repetidas. Los trabajos experimentales existentes en vigas de hormigón armado sin cercos evidenciaron diferencias significativas entre los modos de fallo ante cargas estáticas y cíclicas. Estos trabajos llegaron a la conclusión de que estos elementos diseñados para tener un fallo dúctil por flexión pueden llegar a desarrollar un tipo de fallo frágil por cortante cuando se ven sometidos a cargas repetidas. El proceso de rotura por cortante en elementos de hormigón armado sin cercos sometidos a fatiga es un proceso complejo que debe ser estudiado en profundidad debido al carácter frágil de este tipo de fallo. Los trabajos experimentales permitieron comprobar que el origen de este fallo tiene lugar tras la formación de una fisura de cortante a partir de una fisura de flexión formada durante los primeros ciclos en el vano de cortante. Tras la formación de esta fisura, esta se va propagando hacia la cabeza de compresión hasta que finalmente se produce el fallo como consecuencia de la destrucción de la cabeza de compresión cuando la altura alcanzada por esta es insuficiente para resistir la fuerza de compresión aplicada en esta zona. Por otra parte, la propagación de esta fisura diagonal puede desarrollarse por completo en el instante en el que esta se forma derivando en un tipo de fallo por cortante más frágil que el anterior. El proceso de fatiga es estudiado en esta Tesis mediante un modelo mecánico. Por una parte, se propone un modelo predictivo para determinar el número de ciclos acumulados hasta que se forma la fisura diagonal en función del estado tensional que se tiene en la punta de una fisura crítica de flexión formada en los primeros ciclos. Por otra parte, la resistencia a fatiga tras la formación de la fisura diagonal se analiza teniendo en cuenta el daño por fatiga acumulado en la cabeza de compresión y las variables que afectan a la propagación de esta fisura de cortante. Para la evaluación de la resistencia a fatiga tras la formación de la fisura crítica de cortante en este tipo de elementos, se plantea un modelo teórico basado en conceptos de Mecánica de la Fractura adaptados al hormigón. Este modelo puede ser aplicado a vigas de hormigón armado sin cercos de canto constante o variable siguiendo diferentes procedimientos. Una campaña experimental ha sido llevada a cabo con el objetivo de estudiar el comportamiento a cortante de vigas de hormigón armado sin cercos de canto variable sometidas a cargas estáticas y de fatiga. Se han desarrollado un total de diez ensayos estáticos y de fatiga para diferentes niveles de carga y esbelteces de cortante, teniendo lugar diferentes modos de fallo. Estos elementos fueron diseñados para reproducir, a escala real y de forma simplificada, los voladizos laterales de las losas superiores de tableros de puentes de carretera de hormigón. Los resultados experimentales demostraron que el tipo de fallo desarrollado depende de varios parámetros como por ejemplo el nivel de carga máxima, el nivel de oscilación de tensiones en la armadura longitudinal, la esbeltez de cortante o la calidad del hormigón utilizado entre otros. Para valores similares de esbeltez de cortante, los ensayos de fatiga realizados permitieron comprobar que la rotura por cortante de estos elementos está asociada a niveles de carga máxima elevados, mientras que el fallo por fatiga de la armadura longitudinal tiene mayor probabilidad de ocurrir en elementos sometidos a elevados niveles de oscilación de tensiones en esta armadura. Además, estos ensayos han sido analizados a través del modelo propuesto para tratar de comprender el comportamiento resistente de estos elementos sometidos a cargas de fatiga. Concrete structures are able to suffer fatigue when they are subjected to high number of cyclic loads. Many of these need not shear reinforcement to satisfy static design requirements, such as bridge deck slabs, retaining walls, bridge approach slabs, wind towers or maritime structures among others. Many codes of practice do not include a verification of the shear fatigue safety. Moreover, those which include it still prefer empirical S-N-based approaches that provide the number of cycles as a function of applied forces. S-N models are practical but they do not provide information to understand the shear fatigue process. The main objective of this Thesis is to study shear behaviour of reinforced concrete elements without stirrups subjected to fatigue loads. In addition, the analysis is extended in order to study the transverse behaviour of cantilever slabs of concrete bridges that traditionally are designed without shear reinforcement. These elements usually are designed on the basis of static strength and it is unusual that codes consider fatigue strength of concrete in shear. Accordingly, it is important to take into account the fatigue behaviour of structural members subjected to cyclic loads although these loads are lower than those which produce the static failure. Existing experimental works show important differences between the static and cyclic failure modes of reinforced concrete beams without stirrups. These works concluded that beams without transverse reinforcement, designed to have a ductile failure mode in flexure, can submit a brittle shear failure mode when they are subjected to repeated loads. Shear fatigue failure of reinforced concrete beams without stirrups is a rather complex process from the mechanical viewpoint. Since it leads to a brittle failure mode it should be better understood. Experimental evidence indicates that a diagonal crack first develops from the inclination of flexural cracks in the shear span. Thereafter, the diagonal crack propagates into the compression zone. Failure normally takes place by the destruction of the compression zone when its depth is too small to resist the applied force. The propagation of the diagonal crack can also be instantaneous, leading to sudden diagonal cracking fatigue failure rather than shear-compression failure. Fatigue process is studied in this Thesis on a mechanical basis. On the one hand, a predictive model is derived to obtain the number of cycles up to diagonal cracking, as a function of the stress state at the tip of a critical flexural crack. On the other hand, the residual fatigue strength after diagonal cracking is analyzed taking into account the fatigue damage accumulated by the compression zone and the variables affecting the propagation of the diagonal crack. In order to assess the residual fatigue strength after diagonal cracking of such elements, a theoretical model is proposed based on concepts from fracture mechanics adapted to concrete. This model can be successfully applied for straight or haunched reinforced concrete beams without stirrups following different procedures. In order to achieve a more advanced knowledge in this subject, an experimental campaign has been carried out with the aim of study the shear behaviour of reinforced concrete haunched beams without stirrups subjected to static and fatigue loads. A total of ten static and fatigue tests have been performed with distinct load levels and shear span-to-depth ratios, presenting different failures modes. These elements were designed to reproduce in a simplified form the cantilever slab of concrete bridges at real scale. Experimental results showed that the type of failure depends on several parameters as for example the maximum load level, the stress oscillation level on the longitudinal reinforcement, the shear span-to-depth ratio or the quality of the concrete used among others. For a similar value of the shear span-to-depth ratio, tests evidenced that shear fatigue failure is related to high maximum load levels, while steel fatigue failure is easier to occur in elements subjected to high stress oscillation level on the reinforcement bars. Besides, these tests have been analyzed through the proposed model in order to clarify the structural behaviour of such elements subjected to fatigue loads.