18 resultados para partial Delaunay triangulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The requirements for a good stand in a no-till field are the same as those for conventional planting as well as added field and machinery management. Among the various factors that contribute towards producing a successful maize crop, seed depth placement is a key determinant. Although most no-till planters on the market work well under good soil and residue conditions, adjustments and even modifications are frequently needed when working with compacted or wet soils or with heavy residues. The main objective of this study, carried out in 2010, 2011 and 2012, was to evaluate the vertical distribution and spatial variability of seed depth placement in a maize crop under no-till conditions, using precision farming technologies and conventional no-till seeders. The results obtained indicate that the seed depth placement was affected by soil moisture content and forward speed. The seed depth placement was negatively correlated with soil resistance and seeding depth had a significant impact on mean emergence time and the percentage of emerged plants. Shallow average depth values and high coefficients of variation suggest a need for improvements in controlling the seeders’ sowing depth mechanism or more accurate calibration by operators in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-line partial discharge (PD) measurements have become a common technique for assessing the insulation condition of installed high voltage (HV) insulated cables. When on-line tests are performed in noisy environments, or when more than one source of pulse-shaped signals are present in a cable system, it is difficult to perform accurate diagnoses. In these cases, an adequate selection of the non-conventional measuring technique and the implementation of effective signal processing tools are essential for a correct evaluation of the insulation degradation. Once a specific noise rejection filter is applied, many signals can be identified as potential PD pulses, therefore, a classification tool to discriminate the PD sources involved is required. This paper proposes an efficient method for the classification of PD signals and pulse-type noise interferences measured in power cables with HFCT sensors. By using a signal feature generation algorithm, representative parameters associated to the waveform of each pulse acquired are calculated so that they can be separated in different clusters. The efficiency of the clustering technique proposed is demonstrated through an example with three different PD sources and several pulse-shaped interferences measured simultaneously in a cable system with a high frequency current transformer (HFCT).