21 resultados para mismatched uncertainties


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propagation of nuclear data uncertainties in reactor calculations is interesting for design purposes and libraries evaluation. Previous versions of the GRS XSUSA library propagated only neutron cross section uncertainties. We have extended XSUSA uncertainty assessment capabilities by including propagation of fission yields and decay data uncertainties due to the their relevance in depletion simulations. We apply this extended methodology to the UAM6 PWR Pin-Cell Burnup Benchmark, which involves uncertainty propagation through burnup.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propagation of nuclear data uncertainties to calculated values is interesting for design purposes and libraries evaluation. XSUSA, developed at GRS, propagates cross section uncertainties to nuclear calculations. In depletion simulations, fission yields and decay data are also involved and suppose a possible source of uncertainty that must be taken into account. We have developed tools to generate varied fission yields and decay libraries and to propagate uncertainties trough depletion in order to complete the XSUSA uncertainty assessment capabilities. A simple test to probe the methodology is defined and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An uncertainty propagation methodology based on the Monte Carlo method is applied to PWR nuclear design analysis to assess the impact of nuclear data uncertainties. The importance of the nuclear data uncertainties for 235,238 U, 239 Pu, and the thermal scattering library for hydrogen in water is analyzed. This uncertainty analysis is compared with the design and acceptance criteria to assure the adequacy of bounding estimates in safety margins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cualquier estructura vibra según unas frecuencias propias definidas por sus parámetros modales (frecuencias naturales, amortiguamientos y formas modales). A través de las mediciones de la vibración en puntos clave de la estructura, los parámetros modales pueden ser estimados. En estructuras civiles, es difícil excitar una estructura de manera controlada, por lo tanto, las técnicas que implican la estimación de los parámetros modales sólo registrando su respuesta son de vital importancia para este tipo de estructuras. Esta técnica se conoce como Análisis Modal Operacional (OMA). La técnica del OMA no necesita excitar artificialmente la estructura, atendiendo únicamente a su comportamiento en servicio. La motivación para llevar a cabo pruebas de OMA surge en el campo de la Ingeniería Civil, debido a que excitar artificialmente con éxito grandes estructuras no sólo resulta difícil y costoso, sino que puede incluso dañarse la estructura. Su importancia reside en que el comportamiento global de una estructura está directamente relacionado con sus parámetros modales, y cualquier variación de rigidez, masa o condiciones de apoyo, aunque sean locales, quedan reflejadas en los parámetros modales. Por lo tanto, esta identificación puede integrarse en un sistema de vigilancia de la integridad estructural. La principal dificultad para el uso de los parámetros modales estimados mediante OMA son las incertidumbres asociadas a este proceso de estimación. Existen incertidumbres en el valor de los parámetros modales asociadas al proceso de cálculo (internos) y también asociadas a la influencia de los factores ambientales (externas), como es la temperatura. Este Trabajo Fin de Máster analiza estas dos fuentes de incertidumbre. Es decir, en primer lugar, para una estructura de laboratorio, se estudian y cuantifican las incertidumbres asociadas al programa de OMA utilizado. En segundo lugar, para una estructura en servicio (una pasarela de banda tesa), se estudian tanto el efecto del programa OMA como la influencia del factor ambiental en la estimación de los parámetros modales. Más concretamente, se ha propuesto un método para hacer un seguimiento de las frecuencias naturales de un mismo modo. Este método incluye un modelo de regresión lineal múltiple que permite eliminar la influencia de estos agentes externos. A structure vibrates according to some of its vibration modes, defined by their modal parameters (natural frequencies, damping ratios and modal shapes). Through the measurements of the vibration at key points of the structure, the modal parameters can be estimated. In civil engineering structures, it is difficult to excite structures in a controlled manner, thus, techniques involving output-only modal estimation are of vital importance for these structure. This techniques are known as Operational Modal Analysis (OMA). The OMA technique does not need to excite artificially the structure, this considers its behavior in service only. The motivation for carrying out OMA tests arises in the area of Civil Engineering, because successfully artificially excite large structures is difficult and expensive. It also may even damage the structure. The main goal is that the global behavior of a structure is directly related to their modal parameters, and any variation of stiffness, mass or support conditions, although it is local, is also reflected in the modal parameters. Therefore, this identification may be within a Structural Health Monitoring system. The main difficulty for using the modal parameters estimated by an OMA is the uncertainties associated to this estimation process. Thus, there are uncertainties in the value of the modal parameters associated to the computing process (internal) and the influence of environmental factors (external), such as the temperature. This Master’s Thesis analyzes these two sources of uncertainties. That is, firstly, for a lab structure, the uncertainties associated to the OMA program used are studied and quantified. Secondly, for an in-service structure (a stress-ribbon footbridge), both the effect of the OMA program and the influence of environmental factor on the modal parameters estimation are studied. More concretely, a method to track natural frequencies of the same mode has been proposed. This method includes a multiple linear regression model that allows to remove the influence of these external agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Una estructura vibra con la suma de sus infinitos modos de vibración, definidos por sus parámetros modales (frecuencias naturales, formas modales y coeficientes de amortiguamiento). Estos parámetros se pueden identificar a través del Análisis Modal Operacional (OMA). Así, un equipo de investigación de la Universidad Politécnica de Madrid ha identificado las propiedades modales de un edificio de hormigón armado en Madrid con el método Identificación de los sub-espacios estocásticos (SSI). Para completar el estudio dinámico de este edificio, se ha desarrollado un modelo de elementos finitos (FE) de este edificio de 19 plantas. Este modelo se ha calibrado a partir de su comportamiento dinámico obtenido experimentalmente a través del OMA. Los objetivos de esta tesis son; (i) identificar la estructura con varios métodos de SSI y el uso de diferentes ventanas de tiempo de tal manera que se cuantifican incertidumbres de los parámetros modales debidos al proceso de estimación, (ii) desarrollar FEM de este edificio y calibrar este modelo a partir de su comportamiento dinámico, y (iii) valorar la bondad del modelo. Los parámetros modales utilizados en esta calibración han sido; espesor de las losas, densidades de los materiales, módulos de elasticidad, dimensiones de las columnas y las condiciones de contorno de la cimentación. Se ha visto que el modelo actualizado representa el comportamiento dinámico de la estructura con una buena precisión. Por lo tanto, este modelo puede utilizarse dentro de un sistema de monitorización estructural (SHM) y para la detección de daños. En el futuro, podrá estudiar la influencia de los agentes medioambientales, tales como la temperatura o el viento, en los parámetros modales. A structure vibrates according to the sum of its vibration modes, defined by their modal parameters (natural frequencies, damping ratios and modal shapes). These parameters can be identified through Operational Modal Analysis (OMA). Thus, a research team of the Technical University of Madrid has identified the modal properties of a reinforced-concrete-frame building in Madrid using the Stochastic Subspace Identification (SSI) method and a time domain technique for the OMA. To complete the dynamic study of this building, a finite element model (FE) of this 19-floor building has been developed throughout this thesis. This model has been updated from its dynamic behavior identified by the OMA. The objectives of this thesis are to; (i) identify the structure with several SSI methods and using different time blocks in such a way that uncertainties due to the modal parameter estimation are quantified, (ii) develop a FEM of this building and tune this model from its dynamic behavior, and (iii) Assess the quality of the model, the modal parameters used in this updating process have been; thickness of slabs, material densities, modulus of elasticity, column dimensions and foundation boundary conditions. It has been shown that the final updated model represents the structure with a very good accuracy. Thus, this model might be used within a structural health monitoring framework (SHM). The study of the influence of changing environmental factors (such as temperature or wind) on the model parameters might be considered as a future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A temperature accelerated life test on concentrator lattice mismatched Ga0.37In0.63P/Ga0.83In0.17As/Ge triple-junction solar cells-on-carrier is being carried out. The solar cells have been tested at three different temperatures: 125, 145 and 165°C and the nominal photo-current condition (500X) is emulated by injecting current in darkness. The final objective of these tests is to evaluate the reliability, warranty period, and failure mechanism of these solar cells in a moderate period of time. Up to now only the test at 165°C has finished. Therefore, we cannot provide complete reliability information, but we have carried out preliminary data and failure analysis with the current results.