50 resultados para low-frequency fatigue


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The rheological and tribological properties of single-walled carbon nanotube (SWCNT)-reinforced poly(phenylene sulphide) (PPS) and poly(ether ether ketone) (PEEK) nanocomposites prepared via melt-extrusion were investigated. The effectiveness of employing a dual-nanofiller strategy combining polyetherimide (PEI)-wrapped SWCNTs with inorganic fullerene-like tungsten disulfide (IF-WS2) nanoparticles for property enhancement of the resulting hybrid composites was evaluated. Viscoelastic measurements revealed that the complex viscosity ?, storage modulus G?, and loss modulus G? increased with SWCNT content. In the low-frequency region, G? and G? became almost independent of frequency at higher SWCNT loadings, suggesting a transition from liquid-like to solid-like behavior. The incorporation of increasing IF-WS2 contents led to a progressive drop in ? and G? due to a lubricant effect. PEEK nanocomposites showed lower percolation threshold than those based on PPS, ascribed to an improved SWCNT dispersion due to the higher affinity between PEI and PEEK. The SWCNTs significantly lowered the wear rate but only slightly reduced the coefficient of friction. Composites with both nanofillers exhibited improved wear behavior, attributed to the outstanding tribological properties of these nanoparticles and a synergistic reinforcement effect. The combination of SWCNTs with IF-WS2 is a promising route for improving the tribological and rheological performance of thermoplastic nanocomposites.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Novel poly(phenylene sulphide) (PPS) nanocomposites reinforced with an aminated derivative (PPS-NH2) covalently attached to acid-treated single-walled carbon nanotubes (SWCNTs) were prepared via simple melt-blending technique. Their morphology, viscoelastic behaviour, electrical conductivity, mechanical and tribological properties were investigated. Scanning electron microscopy revealed that the grafting process was effective in uniformly dispersing the SWCNTs within the matrix. The storage and loss moduli as a function of frequency increased with the SWCNT content, tending to a plateau in the low-frequency regime. The electrical conductivity of the nanocomposites was considerably enhanced in the range 0.1?0.5 wt% SWCNTs; electrical and rheological percolation thresholds occurred at similar nanotube concentrations. Mechanical tests demonstrated that with only 1.0 wt% SWCNTs the Young's modulus and tensile strength of the matrix improved by 51 and 37%, respectively, without decrement in toughness, ascribed to a very efficient load transfer. A moderate decrease in the friction coefficient and a 75% reduction in wear rate were found for the abovementioned nanotube loading, indicating that PPS-NH2-g-SWCNTs are good tribological additives for thermoplastic polymers. Based on the promising results obtained in this work, it is expected that these nanofillers will be used to develop high-performance thermoplastic/CNT nanocomposites for structural applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Numerous damage models have been developed in order to analyse the seismic behavior. Among the different possibilities existing in the literature, it is very clear that models developed along the lines of Continuum Damage Mechanics are more consistent with the definition of damage like a phenomenon with mechanical consequences as they include explicitly the coupling between damage and mechanical behavior. On the other hand, for seismic processes, phenomena such as low cycle fatigue may have a pronounced effect on the overall behavior of the frames and, therefore, its consideration turns out to be very important. However, many of existing models evaluate the damage only as a function of the maximum amplitude of cyclic deformation without considering the number of cycles. In this paper, a generalization of the simplified model proposed by Flórez is made in order to include the low cycle fatigue. Such model employs in its formulation irreversible thermodynamics and internal state variable theory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is related to the improvement of the output impedance of the Buck converter by means of introducing an additional power path that virtually increases the output capacitance during transients. It is well known that in VRM applications, with wide load steps, voltage overshoots and undershoots may lead to undesired performance of the load. To solve this problem, high-bandwidth high-switching frequency power converters can be applied to reduce the transient time or a big output capacitor can be applied to reduce the output impedance. The first solution can degrade the efficiency by increasing switching losses of the MOSFETS, and the second solution is penalizing the cost and size of the output filter. The Output Impedance Correction Circuit (OICC), as presented here, is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. This feature allows the usage of a low frequency Buck converter with smaller capacitor but satisfying the dynamic requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is related to the improvement of the dynamic performance of the Buck converter by means of introducing an additional power path that virtually increase s the output capacitance during transients, thus improving the output impedance of the converter. It is well known that in VRM applications, with wide load steps, voltage overshoots and undershoots ma y lead to undesired performance of the load. To solve this problem, high-bandwidth high-switching frequency power converter s can be applied to reduce the transient time or a big output capacitor can be applied to reduce the output impedance. The first solution can degrade the efficiency by increasing switching losses of the MOSFETS, and the second solution is penalizing the cost and size of the output filter. The additional energy path, as presented here, is introduced with the Output Impedance Correction Circuit (OICC) based on the Controlled Current Source (CCS). The OICC is using CCS to inject or extract a current n - 1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. This feature allows the usage of a low frequency Buck converter with smaller capacitor but satisfying the dynamic requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El presente Trabajo Fin de Máster pretende llevar a cabo el análisis del comportamiento vibratorio de resonadores de membrana, consistentes en un panel delgado y ligero montado a cierta distancia de un elemento constructivo rígido y pesado. Este tipo de sistemas resonantes son empleados habitualmente como absorbentes de media-baja frecuencia en aplicaciones de acondicionamiento acústico de salas. El análisis hará especial hincapié en la influencia del acoplamiento mecánico-acústico entre la placa vibrante (estructura) y el colchón de aire (fluido) encerrado entre la misma y la pared rígida. En primer lugar, realizaremos el análisis modal experimental del resonador objeto de ensayo a partir de las mediciones de su respuesta vibratoria, con el fin de caracterizar su comportamiento en base a sus primeros modos propios acoplados de flexión. El análisis de las señales vibratorias en el dominio de la frecuencia para la identificación de dicho modos se realizará en el entorno de programación MATLAB, haciendo uso de una herramienta propia que implementa los métodos de cálculo y los algoritmos necesarios para tal fin. Asimismo, simularemos el comportamiento del resonador mediante el método de elementos finitos (FEM), utilizando las aplicaciones ANSYS y SYSNOISE, considerando diferentes condiciones frontera en el modelo generado. Los resultados aquí obtenidos serán de utilidad para complementar aquellos obtenidos de forma experimental a la hora de extraer conclusiones prácticas del análisis realizado. SUMMARY. This Master's Thesis intends to carry out the analysis of the vibratory behaviour of resonance absorbers, consisting of a thin and lightweight panel mounted at a distance from a rigid wall. Such systems are commonly used as sound absorption systems for mid-low frequency in room acoustics applications. The analysis will emphasize the influence of mechanical-acoustic coupling between the vibrating plate (structure) and the air cushion (acoustic element) enclosed behind it. First of all, we are performing the experimental modal analysis of the resonance absorber under test from the vibrational response measurements, in order to characterize its behaviour based on its first bending coupled-modes. The analysis of vibration signals in the frequency domain for the identification of such modes will be made in MATLAB programming environment, using a proprietary tool that implements the calculation methods and algorithms needed for this purpose. Furthermore, we are simulating the behaviour of the resonance absorber applying the Finite Element Method (FEM) – using ANSYS and SYSNOISE applications - considering different boundary conditions in the model created. The results from the simulation will be useful to complement those obtained experimentally when drawing practical conclusions from this analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Las nanopartículas de metales nobles (especialmente las de oro) tienen un gran potencial asociado al desarrollo de sistemas de terapia contra el cáncer debido principalmente a sus propiedades ópticas, ya que cuando son irradiadas con un haz de luz sintonizado en longitud de onda con su máximo de Resonancia de Plasmón Superficial, absorben de manera muy eficiente dicha luz y la disipan rápidamente al medio en forma de calor localizado. Esta característica por tanto, puede ser aprovechada para conseguir elevar la temperatura de células tumorales hasta sobrepasar umbrales a partir de los cuales se produciría la muerte celular. Partiendo de estos principios, esta tesis se centra en el desarrollo y la caracterización de una serie de prototipos de hipertermia óptica basados en la irradiación de nanopartículas de oro con un haz de luz adecuado, así como en la aplicación in vitro de la terapia sobre células cancerígenas. Además, el trabajo se orienta a identificar y comprender los procesos mecánicos y térmicos asociados a este tipo de hipertermia, y a desarrollar modelos que los describan, estudiando y planteando nuevas formas de irradiación, para, en última instancia, poder optimizar los procesos descritos y hacerlos más efectivos. Los resultados obtenidos indican que, el uso de nanopartículas de oro, y más concretamente de nanorods de oro, para llevar a cabo terapias de hipertermia óptica, permite desarrollar terapias muy efectivas para inducir muerte en células cancerígenas, especialmente en tumores superficiales, o como complemento quirúrgico en tumores internos. Sin embargo, los efectos de la toxicidad de las nanopartículas de oro, aún deben ser detalladamente estudiados, ya que este tipo de terapias sólo será viable si se consigue una completa biocompatibilidad. Por otro lado, el estudio exhaustivo de los procesos térmicos que tienen lugar durante la irradiación de las nanopartículas ha dado lugar a una serie de modelos que permiten determinar la efectividad fototérmica de las nanopartículas y además, visualizar la evolución de la temperatura tanto a escala nanométrica como a escala macrométrica, en función de los parámetros ópticos y térmicos del sistema. El planteamiento de nuevas formas de irradiación y el desarrollo de dispositivos orientados a estudiar los fenómenos mecánicos que tienen lugar durante la irradiación pulsada de baja frecuencia y baja potencia de nanopartículas de oro, ha dado lugar a la detección de ondas de presión asociadas a procesos de expansión termoelástica, abriendo la puerta al desarrollo de terapias de hipertermia que combinen la muerte celular producida por calentamiento con la muerte derivada de los fenómenos mecánicos descritos.VII Noble metal nanoparticles (especially gold ones), have a huge potential in the development of therapy systems against cancer mainly due to their optical properties, so that, when these particles are irradiated with a light that is syntonized in wavelength with their maximum of Surface Plasmon Resonance, they effectively absorb and dissipate the light to the surrounding medium as localized heat. We can take advantage of this characteristic for rising the temperature of cancer cells above the threshold at which cellular death would occur. From these principles, this thesis is oriented to the development and characterization of a series of optical hyperthermia prototypes based on the irradiation of gold nanoparticles using the suitable light, and on the in vitro application of this therapy over cancer cells, to understand the mechanical and thermal processes associated with this kind of hyperthermia, developing descriptive models, and to study and to approach new ways of irradiation in order to, ultimately, optimize the described processes and make them more effective. The obtained results show that, the use of gold nanoparticles, and more specifically, of gold nanorods, to carry out optical hyperthermia therapies, allows the development of very effective therapies in order to induce death in VIII cancer cells, especially in superficial tumors, or like surgical complement in more internal tumors. However, the toxicity effects of the gold nanoparticles still need to be studied more detail, because this kind of therapies will be feasible only if a complete biocompatibility is achieved. On the other hand, the exhaustive study of the thermal processes that take place during the irradiation of the nanoparticles resulted in a series of models that allow the determination of the photothermal efficiency of the nanoparticles and also the visualization of the temperature evolution, both at nanoscale and at macroscale, as a function of the optical and thermal parameters of the system. The proposal of new ways of irradiation and the development of devices oriented to study the mechanical effects that take place during the low frequency and low power pulsing irradiation of gold nanoparticles has led to the detection of pressure waves associated to thermoelastic expansion processes, opening the door to the development of hyperthermia therapies that combine the cellular death due to the heating with the death derived from the described mechanical phenomena.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new type of domain for nematic liquid crystals with a twisted-wedge structure is presented. This new type of domain appears from the low frequency range to 10 kHz. This behavior was observed for square and pulsed excitations. The liquid crystal was N-(p-methoxybenzylidene)-p'-butylaniline) (MBBA) used at room temperature. These domains offer a higher degree of complexity than conventional Williams domains. The corresponding stability chart is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The excitation of Fast Magnetosonic (FMS)waves by a cylindrical array of parallel tethers carrying timemodulated current is discussed. The tethers would fly vertical in the equatorial plane, which is perpendicular to the geomagnetic field when its tilt is ignored, and would be stabilized by the gravity gradient. The tether array would radiate a single FMS wave. In the time-dependent background made of geomagnetic field plus radiated wave, plasma FMS perturbations are excited in the array vicinity through a parametric instability. The growth rate is estimated by truncating the evolution equation for FMS perturbations to the two azimuthal modes of lowest order. Design parameters such as tether length and number, required power and mass are discussed for Low Earth Orbit conditions. The array-attached wave structure would have the radiated wave controlled by the intensity and modulation frequency of the currents, making an active experiment on non-linear low frequency waves possible in real space plasma conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Se realizará un análisis en baja frecuencia del comportamiento de sistemas vibratorios excitados principalmente por un motor eléctrico. El sistema está formado por un motor eléctrico acoplado a un volante de inercia que produce una carga sobre citado motor diferente según las configuraciones adoptadas, todo ello montado sobre una base metálica de acero, soportada esta, mediante resortes de diferente características. El estudio contemplará la identificación de frecuencias de excitación, resonancias, pérdidas de inserción de los sistemas, transmisibilidad, problemas de alineamiento, desajustes, modos propios... para cada una de las diferentes situaciones en las que opera el sistema. ABSTRACT. In this Project will proceed to an behavior analysis of vibrating systems in low frequency mainly excited by an electric motor. The system is comprised of an electric motor coupled to inertial flywheel (o flywheel) which produces a different load upon said engine according to the configurations adopted. This system is mounted on a steel metal base which is supported by springs of different characteristics. This study will consider the excitation frequency identification, system resonances, insertion loss, transmissibility, shaft dealignment, eccentricities, mismatches, modal frequencies of the plate… for each of the situations in which the system operates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Una de las principales causas del ruido en nuestras ciudades es el tráfico rodado. El ruido generado por los vehículos no es sólo debido al motor, sino que existen diversas fuentes de ruido en los mismos, entre las que se puede destacar el ruido de rodadura. Para localizar las causas del ruido e identificar las principales fuentes del mismo se han utilizado en diversos estudios las técnicas de coherencia y las técnicas basadas en arrays. Sin embargo, en la bibliografía existente, no es habitual encontrar el uso de estas técnicas en el sector automovilístico. En esta tesis se parte de la premisa de la posibilidad de usar estas técnicas de medida en coches, para demostrar a la largo de la misma su factibilidad y su bondad para evaluar las fuentes de ruido en dos condiciones distintas: cuando el coche está parado y cuando está en movimiento. Como técnica de coherencia se elige la de Intensidad Selectiva, utilizándose la misma para evaluar la coherencia existente entre el ruido que llega a los oídos del conductor y la intensidad radiada por distintos puntos del motor. Para la localización de fuentes de ruido, las técnicas basadas en array son las que mejores resultados ofrecen. Statistically Optimized Near-field Acoustical Holography (SONAH) es la técnica elegida para la localización y caracterización de las fuentes de ruido en el motor a baja frecuencia. En cambio, Beamforming es la técnica seleccionada para el caso de media-alta frecuencia y para la evaluación de las fuentes de ruido cuando el coche se encuentra en movimiento. Las técnicas propuestas no sólo pueden utilizarse en medidas reales, sino que además proporcionan abundante información y frecen una gran versatilidad a la hora de caracterizar fuentes de ruido. ABSTRACT One of the most important noise causes in our cities is the traffic. The noise generated by the vehicles is not only due to the engine, but there are some other noise sources. Among them the tyre/road noise can be highlighted. Coherence and array based techniques have been used in some research to locate the noise causes and identify the main noise sources. Nevertheless, it is not usual in the literature to find the application of this kind of techniques in the car sector. This Thesis starts taking into account the possibility of using this kind of measurement techniques in cars, to demonstrate their feasability and their quality to evaluate the noise sources under two different conditions: when the car is stopped and when it is in movement. Selective Intensity was chosen as coherence technique, evaluating the coherence between the noise in the driver’s ears and the intensity radiated in different points of the engine. Array based techniques carry out the best results to noise source location. Statistically Optimized Near-field Acoustical Holography (SONAH) is the measurement technique chosen for noise source location and characterization in the engine at low frequency. On the other hand, Beamforming is the technique chosen in the case of medium-high frequency and to characterize the noise sources when the car is in movement. The proposed techniques not only can be used in actual measurements, but also provide a lot of information and are very versatile to noise source characterization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A numerical description is given for the pulsating emission of droplets from an electrified meniscus of an inviscid liquid of infinite electrical conductivity which is injected at a constant flow rate into a region of uniform, continuous or time periodic, electric field. Under a continuous field, the meniscus attains a periodic regime in which bursts of tiny droplets are emitted from its tip. At low electric fields this regime consists of sequences of emission bursts interspersed with sequences of meniscus oscillations without droplet emission, while at higher fields the bursts occur periodically. These results are in qualitative agreement with experimental results in the literature. Under a time periodic electric field with square waveform, the electric stress that acts on the surface of the liquid while the field is on may generate a tip that emits tiny droplets or may accelerate part of the meniscus and lead to a second emission mode in which a few large droplets are emitted after the electric field is turned off. Conditions under which each emission mode or a combination of the two are realized are discussed for low frequency oscillatory fields. A simplified model is proposed for high electric field frequencies, of the order of the capillary frequency of the meniscus. This model allows computing the average emission rate as a function of the amplitude, duration and bias of the electric field square wave, and shows that droplet emission fails to follow the applied field above a certain frequency

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main focus of this paper is on hydrodynamic modelling of a semisubmersible platform (which can support a 1.5MW wind turbine and is composed by three buoyant columns connected by bracings) with especial emphasis on the estimation of the wave drift components and their effects on the design of the mooring system. Indeed, with natural periods of drift around 60 seconds, accurate computation of the low-frequency second-order components is not a straightforward task. As methods usually adopted when dealing with the slow-drifts of deep-water moored systems, such as Newman?s approximation, have their errors increased by the relatively low resonant periods, and as the effects of depth cannot be ignored, the wave diffraction analysis must be based on full Quadratic Transfer Functions (QTF) computations. A discussion on the numerical aspects of performing such computations is presented, making use of the second-order module available with the seakeeping software WAMIT®. Finally, the paper also provides a preliminary verification of the accuracy of the numerical predictions based on the results obtained in a series of model tests with the structure fixed in bichromatic waves.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The 6 cylinder servo-hydraulic loading system of CEDEX's track box (250 kN, 50 Hz) has been recently implemented with a new piezoelectric loading system (±20 kN, 300 Hz) allowing the incorporation of low amplitude high frequency dynamic load time histories to the high amplitude low frequency quasi-static load time histories used so far in the CEDEX's track box to assess the inelastic long term behavior of ballast under mixed traffic in conventional and high- speed lines. This presentation will discuss the results obtained in the first long-duration test performed at CEDEX's track box using simultaneously both loading systems, to simulate the pass-by of 6000 freight vehicles (1M of 225 kN axle loads) travelling at a speed of 120 km/h over a line with vertical irregularities corresponding to a medium quality lin3e level. The superstructure of the track tested at full scale consisted of E 60 rails, stiff rail pads (mayor que 450 kN/mm), B90.2 sleepers with USP 0.10 N/mm and a 0.35 m thick ballast layer of ADIF first class. A shear wave velocity of 250 m/s can be assumed for the different layers of the track sub-base. The ballast long-term settlements will be compared with those obtained in a previous long-duration quasi- static test performed in the same track, for the RIVAS [EU co-funded] project, in which no dynamic loads where considered. Also, the results provided by a high diameter cyclic triaxial cell with ballast tested in full size will be commented. Finally, the progress made at CEDEX's Geotechnical Laboratory to reproduce numerically the long term behavior of ballast will be discussed.