29 resultados para heat flux sensor
Resumo:
The peak temperature in the corona of plasma ejected by a laser-irradiated slab is discussed in terms of a one-electron-temperature model. Both heat-flux saturation and pulse rise-time effects are considered;the intensity in the rising half of the pulse is approximated by a linear function of time, I(t) = Iot/r. The temperature is found to be proportional to (IQX2)273 and a function of I0X4/r. Above a certain value of I0X4/T, the plasma presents two characteristic temperatures (at saturation and at the critical surface) which can be identified with experimentally observed cold- and hot-electron temperatures. The results are compared with extensive experimental data available for both nd and CO2 lasers, I0(W'cnf2) X2 (/um) starting around 1012. The agreement is good if substantial flux inhibition is assumed (flux-limit factor f = 0.03), and fails for I0X2 above 1O1S. Results for both ablation pressure and mass ablation rate are also given.
Resumo:
The fluid-dynamics of the corona ejected by laser-fusion targets in the direct-drive approach (thermal radiation and atomic physics unimportant) is discussed. A two-fluid model involves inverse bremsstrahlung absorption, refraction, different ion and electron temperatures with energy exchange, different ion and electron velocities and magnetic field generation, and their effect on ion-electron friction and heat flux. Four dimensionless parameters determine coronal regimes for one-dimensional flows under uniform irradiation. One additional parameter is involved in two-dimensional problems,including the stability of one-dimensional flows, and the smoothing of nonuniform driving.
Resumo:
Existe un creciente interés internacional por el ahorro energético y la sostenibilidad en la edificación con importantes repercusiones en la Arquitectura. La inercia térmica es un parámetro fundamental para poder valorar energéticamente un edificio en condiciones reales. Para ello es necesario cambiar el enfoque tradicional de transmisión de calor en régimen estacionario por otro en régimen dinámico en el que se analizan las ondas térmicas y el flujo de calor oscilante que atraviesan los cerramientos. Los parámetros que definen la inercia térmica son: el espesor, la difusividad y el ciclo térmico. A su vez la difusividad está determinada por la conductividad térmica, la densidad y el calor específico del material. De estos parámetros la conductividad es el más complejo, variable y difícil de medir, especialmente en los cerramientos de tierra debido a su heterogeneidad y complejidad higrotérmica. En general, los métodos de medida de la conductividad o transmitancias en los paramentos presentan inconvenientes a la hora de medir un edificio construido con tierra: dificultades de implementación, el elevado coste o la fiabilidad de los resultados, principalmente. El Método de la Aguja Térmica (MAT) se basa en el principio de la evolución en el tiempo del calor emitido por una fuente lineal al insertarse en el seno de un material. Se ha escogido este método porque resulta práctico, de bajo coste y de fácil aplicación a gran escala pero tiene serios problemas de fiabilidad y exactitud. En esta tesis se desarrolla un método de medida de la conductividad térmica para Piezas de Albañilería de Tierra Cruda en laboratorio basado en el MAT, se mejora su fiabilidad, se analiza su incertidumbre, se compara con otros métodos de referencia y se aplica en adobes, Bloques de Tierra Comprimida y probetas de tierra estabilizada con distintas proporciones de paja. Este método servirá de base a una posterior aplicación in situ. Finalmente se proponen modelos matemáticos para mejorar la exactitud del dispositivo utilizado y para la estimación de la conductividad de cerramientos de tierra en función de su densidad. Con los resultados obtenidos se analizan las posibilidades de amortiguación y retardo de las ondas térmicas y capacidad de almacenaje de energía de los cerramientos en función de su densidad y humedad. There is growing international interest in energy saving and sustainability in buildings with significant impact on Architecture. Thermal inertia is a key parameter to assess energy in buildings in real conditions. This requires changing the traditional approach to heat transfer in steady state by another in dynamic regime which analyzes the thermal waves and oscillating heat flux passing through the external walls. The parameters defining the thermal inertia are: the thickness, the diffusivity and the thermal cycle. In turn, the diffusivity is determined by the thermal conductivity, density and specific heat of the material. Of these parameters, thermal conductivity is the most complex, variable and difficult to measure, especially in earth walls due to their heterogeneity and hygrothermal complexity. In general, the methods of measurement of conductivity and transmittance in walls have drawbacks when measuring a building with earth: implementation difficulties, high cost, or reliability of the results, mainly. The Thermal Needle Procedure (TNP) is based on the principle of evolution in time of heat from a line source when inserted within a material. This method was chosen because it is a practical, low cost and easy to implement on a large scale but has serious problems of reliability and accuracy. This thesis develops a laboratory method for measuring the thermal conductivity of Masonry Units Unfire Earth-based based on TNP, its uncertainty is analyzed, compared to other reference methods and applies in adobes, Compressed Earth Blocks and stabilized soil specimens with different proportions of straw. This method will form the basis of a subsequent application in situ. Finally, mathematical models are proposed to improve the accuracy of the device used, and to estimate the conductivity of earth enclosures depending on its density. With the results obtained earth enclosures are analyzed to estimate their possibilities of delay and buffer of termal waves and energy storage capacity according to their density and moisture.
Resumo:
A two electron-temperature, quasi-steady model of the corona of a laser-ablated pellet is considered. Ablation pressure, critical radius and mass flow rate are determined. Results are close to those obtained with heat flux saturation well below the free-streaming limit.
Resumo:
It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2. Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature.
Resumo:
En el campo de la fusión nuclear y desarrollándose en paralelo a ITER (International Thermonuclear Experimental Reactor), el proyecto IFMIF (International Fusion Material Irradiation Facility) se enmarca dentro de las actividades complementarias encaminadas a solucionar las barreras tecnológicas que aún plantea la fusión. En concreto IFMIF es una instalación de irradiación cuya misión es caracterizar materiales resistentes a condiciones extremas como las esperadas en los futuros reactores de fusión como DEMO (DEMOnstration power plant). Consiste de dos aceleradores de deuterones que proporcionan un haz de 125 mA y 40 MeV cada uno, que al colisionar con un blanco de litio producen un flujo neutrónico intenso (1017 neutrones/s) con un espectro similar al de los neutrones de fusión [1], [2]. Dicho flujo neutrónico es empleado para irradiar los diferentes materiales candidatos a ser empleados en reactores de fusión, y las muestras son posteriormente examinadas en la llamada instalación de post-irradiación. Como primer paso en tan ambicioso proyecto, una fase de validación y diseño llamada IFMIFEVEDA (Engineering Validation and Engineering Design Activities) se encuentra actualmente en desarrollo. Una de las actividades contempladas en esta fase es la construcción y operación de una acelarador prototipo llamado LIPAc (Linear IFMIF Prototype Accelerator). Se trata de un acelerador de deuterones de alta intensidad idéntico a la parte de baja energía de los aceleradores de IFMIF. Los componentes del LIPAc, que será instalado en Japón, son suministrados por diferentes países europeos. El acelerador proporcionará un haz continuo de deuterones de 9 MeV con una potencia de 1.125 MW que tras ser caracterizado con diversos instrumentos deberá pararse de forma segura. Para ello se requiere un sistema denominado bloque de parada (Beam Dump en inglés) que absorba la energía del haz y la transfiera a un sumidero de calor. España tiene el compromiso de suministrar este componente y CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) es responsable de dicha tarea. La pieza central del bloque de parada, donde se para el haz de iones, es un cono de cobre con un ángulo de 3.5o, 2.5 m de longitud y 5 mm de espesor. Dicha pieza está refrigerada por agua que fluye en su superficie externa por el canal que se forma entre el cono de cobre y otra pieza concéntrica con éste. Este es el marco en que se desarrolla la presente tesis, cuyo objeto es el diseño del sistema de refrigeración del bloque de parada del LIPAc. El diseño se ha realizado utilizando un modelo simplificado unidimensional. Se han obtenido los parámetros del agua (presión, caudal, pérdida de carga) y la geometría requerida en el canal de refrigeración (anchura, rugosidad) para garantizar la correcta refrigeración del bloque de parada. Se ha comprobado que el diseño permite variaciones del haz respecto a la situación nominal siendo el flujo crítico calorífico al menos 2 veces superior al nominal. Se han realizado asimismo simulaciones fluidodinámicas 3D con ANSYS-CFX en aquellas zonas del canal de refrigeración que lo requieren. El bloque de parada se activará como consecuencia de la interacción del haz de partículas lo que impide cualquier cambio o reparación una vez comenzada la operación del acelerador. Por ello el diseño ha de ser muy robusto y todas las hipótesis utilizadas en la realización de éste deben ser cuidadosamente comprobadas. Gran parte del esfuerzo de la tesis se centra en la estimación del coeficiente de transferencia de calor que es determinante en los resultados obtenidos, y que se emplea además como condición de contorno en los cálculos mecánicos. Para ello por un lado se han buscado correlaciones cuyo rango de aplicabilidad sea adecuado para las condiciones del bloque de parada (canal anular, diferencias de temperatura agua-pared de decenas de grados). En un segundo paso se han comparado los coeficientes de película obtenidos a partir de la correlación seleccionada (Petukhov-Gnielinski) con los que se deducen de simulaciones fluidodinámicas, obteniendo resultados satisfactorios. Por último se ha realizado una validación experimental utilizando un prototipo y un circuito hidráulico que proporciona un flujo de agua con los parámetros requeridos en el bloque de parada. Tras varios intentos y mejoras en el experimento se han obtenido los coeficientes de película para distintos caudales y potencias de calentamiento. Teniendo en cuenta la incertidumbre de las medidas, los valores experimentales concuerdan razonablemente bien (en el rango de 15%) con los deducidos de las correlaciones. Por motivos radiológicos es necesario controlar la calidad del agua de refrigeración y minimizar la corrosión del cobre. Tras un estudio bibliográfico se identificaron los parámetros del agua más adecuados (conductividad, pH y concentración de oxígeno disuelto). Como parte de la tesis se ha realizado asimismo un estudio de la corrosión del circuito de refrigeración del bloque de parada con el doble fin de determinar si puede poner en riesgo la integridad del componente, y de obtener una estimación de la velocidad de corrosión para dimensionar el sistema de purificación del agua. Se ha utilizado el código TRACT (TRansport and ACTivation code) adaptándalo al caso del bloque de parada, para lo cual se trabajó con el responsable (Panos Karditsas) del código en Culham (UKAEA). Los resultados confirman que la corrosión del cobre en las condiciones seleccionadas no supone un problema. La Tesis se encuentra estructurada de la siguiente manera: En el primer capítulo se realiza una introducción de los proyectos IFMIF y LIPAc dentro de los cuales se enmarca esta Tesis. Además se describe el bloque de parada, siendo el diseño del sistema de rerigeración de éste el principal objetivo de la Tesis. En el segundo y tercer capítulo se realiza un resumen de la base teórica así como de las diferentes herramientas empleadas en el diseño del sistema de refrigeración. El capítulo cuarto presenta los resultados del relativos al sistema de refrigeración. Tanto los obtenidos del estudio unidimensional, como los obtenidos de las simulaciones fluidodinámicas 3D mediante el empleo del código ANSYS-CFX. En el quinto capítulo se presentan los resultados referentes al análisis de corrosión del circuito de refrigeración del bloque de parada. El capítulo seis se centra en la descripción del montaje experimental para la obtención de los valores de pérdida de carga y coeficiente de transferencia del calor. Asimismo se presentan los resultados obtenidos en dichos experimentos. Finalmente encontramos un capítulo de apéndices en el que se describen una serie de experimentos llevados a cabo como pasos intermedios en la obtención del resultado experimental del coeficiente de película. También se presenta el código informático empleado para el análisis unidimensional del sistema de refrigeración del bloque de parada llamado CHICA (Cooling and Heating Interaction and Corrosion Analysis). ABSTRACT In the nuclear fusion field running in parallel to ITER (International Thermonuclear Experimental Reactor) as one of the complementary activities headed towards solving the technological barriers, IFMIF (International Fusion Material Irradiation Facility) project aims to provide an irradiation facility to qualify advanced materials resistant to extreme conditions like the ones expected in future fusion reactors like DEMO (DEMOnstration Power Plant). IFMIF consists of two constant wave deuteron accelerators delivering a 125 mA and 40 MeV beam each that will collide on a lithium target producing an intense neutron fluence (1017 neutrons/s) with a similar spectra to that of fusion neutrons [1], [2]. This neutron flux is employed to irradiate the different material candidates to be employed in the future fusion reactors, and the samples examined after irradiation at the so called post-irradiative facilities. As a first step in such an ambitious project, an engineering validation and engineering design activity phase called IFMIF-EVEDA (Engineering Validation and Engineering Design Activities) is presently going on. One of the activities consists on the construction and operation of an accelerator prototype named LIPAc (Linear IFMIF Prototype Accelerator). It is a high intensity deuteron accelerator identical to the low energy part of the IFMIF accelerators. The LIPAc components, which will be installed in Japan, are delivered by different european countries. The accelerator supplies a 9 MeV constant wave beam of deuterons with a power of 1.125 MW, which after being characterized by different instruments has to be stopped safely. For such task a beam dump to absorb the beam energy and take it to a heat sink is needed. Spain has the compromise of delivering such device and CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas) is responsible for such task. The central piece of the beam dump, where the ion beam is stopped, is a copper cone with an angle of 3.5o, 2.5 m long and 5 mm width. This part is cooled by water flowing on its external surface through the channel formed between the copper cone and a concentric piece with the latter. The thesis is developed in this realm, and its objective is designing the LIPAc beam dump cooling system. The design has been performed employing a simplified one dimensional model. The water parameters (pressure, flow, pressure loss) and the required annular channel geometry (width, rugoisty) have been obtained guaranteeing the correct cooling of the beam dump. It has been checked that the cooling design allows variations of the the beam with respect to the nominal position, being the CHF (Critical Heat Flux) at least twice times higher than the nominal deposited heat flux. 3D fluid dynamic simulations employing ANSYS-CFX code in the beam dump cooling channel sections which require a more thorough study have also been performed. The beam dump will activateasaconsequenceofthe deuteron beam interaction, making impossible any change or maintenance task once the accelerator operation has started. Hence the design has to be very robust and all the hypotheses employed in the design mustbecarefully checked. Most of the work in the thesis is concentrated in estimating the heat transfer coefficient which is decisive in the obtained results, and is also employed as boundary condition in the mechanical analysis. For such task, correlations which applicability range is the adequate for the beam dump conditions (annular channel, water-surface temperature differences of tens of degrees) have been compiled. In a second step the heat transfer coefficients obtained from the selected correlation (Petukhov- Gnielinski) have been compared with the ones deduced from the 3D fluid dynamic simulations, obtaining satisfactory results. Finally an experimental validation has been performed employing a prototype and a hydraulic circuit that supplies a flow with the requested parameters in the beam dump. After several tries and improvements in the experiment, the heat transfer coefficients for different flows and heating powers have been obtained. Considering the uncertainty in the measurements the experimental values agree reasonably well (in the order of 15%) with the ones obtained from the correlations. Due to radiological reasons the quality of the cooling water must be controlled, hence minimizing the copper corrosion. After performing a bibligraphic study the most adequate water parameters were identified (conductivity, pH and dissolved oxygen concentration). As part of this thesis a corrosion study of the beam dump cooling circuit has been performed with the double aim of determining if corrosion can pose a risk for the copper beam dump , and obtaining an estimation of the corrosion velocitytodimension the water purification system. TRACT code(TRansport and ACTivation) has been employed for such study adapting the code for the beam dump case. For such study a collaboration with the code responsible (Panos Karditsas) at Culham (UKAEA) was established. The work developed in this thesis has supposed the publication of three articles in JCR journals (”Journal of Nuclear Materials” y ”Fusion Engineering and Design”), as well as presentations in more than four conferences and relevant meetings.
Resumo:
The current magnetic confinement nuclear fusion power reactor concepts going beyond ITER are based on assumptions about the availability of materials with extreme mechanical, heat, and neutron load capacity. In Europe, the development of such structural and armour materials together with the necessary production, machining, and fabrication technologies is pursued within the EFDA long-term fusion materials programme. This paper reviews the progress of work within the programme in the area of tungsten and tungsten alloys. Results, conclusions, and future projections are summarized for each of the programme´s main subtopics, which are: (1) fabrication, (2) structural W materials, (3) W armour materials, and (4) materials science and modelling. It gives a detailed overview of the latest results on materials research, fabrication processes, joining options, high heat flux testing, plasticity studies, modelling, and validation experiments.
Resumo:
En la presente Tesis se realizó un análisis numérico, usando el código comercial Ansys-Fluent, de la refrigeración de una bola de combustible de un reactor de lecho de bolas (PBR, por sus siglas en inglés), ante un escenario de emergencia en el cual el núcleo sea desensamblado y las bolas se dejen caer en una piscina de agua, donde el mecanismo de transferencia de calor inicialmente sería la ebullición en película, implicando la convección y la radiación al fluido. Previamente se realizaron pruebas de validación, comparando los resultados numéricos con datos experimentales disponibles en la literatura para tres geometrías diferentes, lo cual permitió seleccionar los esquemas y modelos numéricos con mejor precisión y menor costo computacional. Una vez identificada la metodología numérica, todas las pruebas de validación fueron ampliamente satisfactorias, encontrándose muy buena concordancia en el flujo de calor promedio con los datos experimentales. Durante estas pruebas de validación se lograron caracterizar numéricamente algunos parámetros importantes en la ebullición en película con los cuales existen ciertos niveles de incertidumbre, como son el factor de acoplamiento entre convección y radiación, y el factor de corrección del calor latente de vaporización. El análisis térmico de la refrigeración de la bola del reactor por ebullición en película mostró que la misma se enfría, a pesar del calor de decaimiento, con una temperatura superficial de la bola que desciende de forma oscilatoria, debido al comportamiento inestable de la película de vapor. Sin embargo, la temperatura de esta superficie tiene una buena uniformidad, notándose que las áreas mejor y peor refrigeradas están localizadas en la parte superior de la bola. Se observó la formación de múltiples domos de vapor en diferentes posiciones circunferenciales, lo cual causa que el área más caliente de la superficie se localice donde se forman los domos más grandes. La separación entre los domos de vapor fue consistente con la teoría hidrodinámica, con la adición de que la separación entre domos se reduce a medida que evolucionan y crecen, debido a la curvatura de la superficie. ABSTRACT A numerical cooling analysis of a PBR fuel pebble, after an emergency scenario in which the nucleus disassembly is made and the pebbles are dropped into a water pool, transmitting heat by film boiling, involving convection and radiation to the fluid, is carried out in this Thesis. First, were performed validation tests comparing the numerical results with experimental works available for three different geometries, which allowed the selection of numerical models and schemes with better precision and lower computational cost. Once identified the numerical methodology, all validation tests were widely satisfactory, finding very good agreement with experimental works in average heat flux. During these validation tests were achieved numerically characterize some important parameters in film boiling with which there are certain levels of uncertainty, such as the coupling factor between convection and radiation, and the correction factor of the latent heat of vaporization. The thermal analysis of pebble cooling by film boiling shows that despite its decay heat, cooling occurs, with pebble surface temperature descending from an oscillatory manner, due to the instability of the vapor film. However, the temperature of this surface has a good uniformity, noting that the best and worst refrigerated area is located at the top of the pebble. The formation of multiple vapor domes at different circumferential positions is observed, which cause that the hottest area of the surface was located where biggest vapor domes were formed. The separation between vapor domes was consistent with the hydrodynamic theory, with the addition that the separation is reduced as the vapor dome evolves and grows, due to the surface curvature.
Resumo:
La operación cíclica de carga y descarga del almacenamiento en los sistemas CAES induce variaciones de presión y temperatura del aire almacenado. Se requiere pues de modelos que predigan la magnitud de dichas actuaciones para lograr una óptima configuración de la planta de potencia. El modelo se deduce directamente de las ecuaciones de conservación de la masa y de la energía para un sistema homogéneo e isótropo. Es resuelto analítica, para ciertos casos límite de interés, y numéricamente. Se somete al modelo a un análisis de sensibilidad para la determinación de los parámetros característicos más influyentes que afectan a las actuaciones de presión y al volumen de almacenamiento requerido. Se observó que el flujo de calor a través del medio circundante al almacenamiento presenta una influencia sobre éste poco despreciable que debe tenerse en cuenta. Se comparan los casos para sistemas adiabáticos e isotermos para calibrar dicha desviación. Además, se esboza un modelo aproximado que describa el comportamiento del almacenamiento con un almacén térmico (AT) acoplado que regule las variaciones de la temperatura del aire inyectado. Abstract Cyclic charge and discharge operation in CAES systems induce pressure and temperatura fluctuations in the storaged air. It is then required a model that properly describes the magnitud of such fluctutions in order to achieve an optimum power plant configuration. This model is directly deduced from the general conservation principles: conservation of mass and energy, applied into homogeneous and isotropic systems. It was solved analytically for certain specific limiting cases of interest as well as numerically. The model was subjected to a sensibility analysis in order to determine the intrinsic parameters that affect the pressure fluctuations as well as the required storage volume the most. Furthermore it was observed that the heat flux through the sourrounding media of the storage has a non-negligible effect that must be taken into account. Adiabatic and isothermal cases are then compared to each other to determine such a deviation. What is more, it is given a general outline about the model which describes the behaviour of the storage coupled with a thermal storage system(TES) that regulates the inyected air temperature.
Resumo:
There are several heat and mass diffusion problems which affect to the IFC chamber design. New simulation models and experiments are needed to take into account the extreme conditions due to ignition pulses and neutron flux
Resumo:
Through the use of the Distributed Fiber Optic Temperature Measurement (DFOT) method, it is possible to measure the temperature in small intervals (on the order of centimeters) for long distances (on the order of kilometers) with a high temporal frequency and great accuracy. The heat pulse method consists of applying a known amount of heat to the soil and monitoring the temperature evolution, which is primarily dependent on the soil moisture content. The use of both methods, which is called the active heat pulse method with fiber optic temperature sensing (AHFO), allows accurate soil moisture content measurements. In order to experimentally study the wetting patterns, i.e. shape, size, and the water distribution, from a drip irrigation emitter, a soil column of 0.5 m of diameter and 0.6 m high was built. Inside the column, a fiber optic cable with a stainless steel sheath was placed forming three concentric helixes of diameters 0.2 m, 0.4 m and 0.6 m, leading to a 148 measurement point network. Before, during, and after the irrigation event, heat pulses were performed supplying electrical power of 20 W/m to the steel. The soil moisture content was measured with a capacitive sensor in one location at depths of 0.1 m, 0.2 m, 0.3 m and 0.4 m during the irrigation. It was also determined by the gravimetric method in several locations and depths before and right after the irrigation. The emitter bulb dimensions and shape evolution was satisfactorily measured during infiltration. Furthermore, some bulb's characteristics difficult to predict (e.g. preferential flow) were detected. The results point out that the AHFO is a useful tool to estimate the wetting pattern of drip irrigation emitters in soil columns and show a high potential for its use in the field.
Resumo:
From the end of 2013 and during the following two years, 20 kt of CO2sc are planned to be injected in a saline reservoir (1500 m depth) at the Hontomín site (NE Spain). The target aquifers are Lower Jurassic limestone formations which are sealed by Lower Cretaceous clay units at the Hontomín site (NE Spain). The injection of CO2 is part of the activities committed in the Technology Development phase of the EC-funded OXYCFB300 project (European Energy Program for Recovery – EEPR, http://www.compostillaproject.eu), which include CO2 injection strategies, risk assessment, and testing and validating monitoring methodologies and techniques. Among the monitoring works, the project is intended to prove that present-day technology is able to monitor the evolution of injected CO2 in the reservoir and to detect potential leakage. One of the techniques is the measurement of CO2 flux at the soil–atmosphere interface, which includes campaigns before, during and after the injection operations. In this work soil CO2 flux measurements in the vicinity of oil borehole, drilled in the eighties and named H-1 to H-4, and injection and monitoring wells were performed using an accumulation chamber equipped with an IR sensor. Seven surveys were carried out from November 2009 to summer 2011. More than 4000 measurements were used to determine the baseline flux of CO2 and its seasonal variations. The measured values were low (from 5 to 13 g m−2 day−1) and few outliers were identified, mainly located close to the H-2 oil well. Nevertheless, these values cannot be associated to a deep source of CO2, being more likely related to biological processes, i.e. soil respiration. No anomalies were recognized close to the deep fault system (Ubierna Fault) detected by geophysical investigations. There, the CO2 flux is indeed as low as other measurement stations. CO2 fluxes appear to be controlled by the biological activity since the lowest values were recorded during autumn-winter seasons and they tend to increase in warm periods. Two reference CO2 flux values (UCL50 of 5 g m−2 d−1 for non-ploughed areas in autumn–winter seasons and 3.5 and 12 g m−2 d−1 for in ploughed and non-ploughed areas, respectively, in spring–summer time, and UCL99 of 26 g m−2 d−1 for autumn–winter in not-ploughed areas and 34 and 42 g m−2 d−1 for spring–summer in ploughed and not-ploughed areas, respectively) were calculated. Fluxes higher than these reference values could be indicative of possible leakage during the operational and post-closure stages of the storage project.
Resumo:
Existe una creciente necesidad de hacer el mejor uso del agua para regadío. Una alternativa eficiente consiste en la monitorización del contenido volumétrico de agua (θ), utilizando sensores de humedad. A pesar de existir una gran diversidad de sensores y tecnologías disponibles, actualmente ninguna de ellas permite obtener medidas distribuidas en perfiles verticales de un metro y en escalas laterales de 0.1-1,000 m. En este sentido, es necesario buscar tecnologías alternativas que sirvan de puente entre las medidas puntuales y las escalas intermedias. Esta tesis doctoral se basa en el uso de Fibra Óptica (FO) con sistema de medida de temperatura distribuida (DTS), una tecnología alternativa de reciente creación que ha levantado gran expectación en las últimas dos décadas. Específicamente utilizamos el método de fibra calentada, en inglés Actively Heated Fiber Optic (AHFO), en la cual los cables de Fibra Óptica se utilizan como sondas de calor mediante la aplicación de corriente eléctrica a través de la camisa de acero inoxidable, o de un conductor eléctrico simétricamente posicionado, envuelto, alrededor del haz de fibra óptica. El uso de fibra calentada se basa en la utilización de la teoría de los pulsos de calor, en inglés Heated Pulsed Theory (HPP), por la cual el conductor se aproxima a una fuente de calor lineal e infinitesimal que introduce calor en el suelo. Mediante el análisis del tiempo de ocurrencia y magnitud de la respuesta térmica ante un pulso de calor, es posible estimar algunas propiedades específicas del suelo, tales como el contenido de humedad, calor específico (C) y conductividad térmica. Estos parámetros pueden ser estimados utilizando un sensor de temperatura adyacente a la sonda de calor [método simple, en inglés single heated pulsed probes (SHPP)], ó a una distancia radial r [método doble, en inglés dual heated pulsed probes (DHPP)]. Esta tesis doctoral pretende probar la idoneidad de los sistemas de fibra óptica calentada para la aplicación de la teoría clásica de sondas calentadas. Para ello, se desarrollarán dos sistemas FO-DTS. El primero se sitúa en un campo agrícola de La Nava de Arévalo (Ávila, España), en el cual se aplica la teoría SHPP para estimar θ. El segundo sistema se desarrolla en laboratorio y emplea la teoría DHPP para medir tanto θ como C. La teoría SHPP puede ser implementada con fibra óptica calentada para obtener medidas distribuidas de θ, mediante la utilización de sistemas FO-DTS y el uso de curvas de calibración específicas para cada suelo. Sin embargo, la mayoría de aplicaciones AHFO se han desarrollado exclusivamente en laboratorio utilizando medios porosos homogéneos. En esta tesis se utiliza el programa Hydrus 2D/3D para definir tales curvas de calibración. El modelo propuesto es validado en un segmento de cable enterrado en una instalación de fibra óptica y es capaz de predecir la respuesta térmica del suelo en puntos concretos de la instalación una vez que las propiedades físicas y térmicas de éste son definidas. La exactitud de la metodología para predecir θ frente a medidas puntuales tomadas con sensores de humedad comerciales fue de 0.001 a 0.022 m3 m-3 La implementación de la teoría DHPP con AHFO para medir C y θ suponen una oportunidad sin precedentes para aplicaciones medioambientales. En esta tesis se emplean diferentes combinaciones de cables y fuentes emisoras de calor, que se colocan en paralelo y utilizan un rango variado de espaciamientos, todo ello en el laboratorio. La amplitud de la señal y el tiempo de llegada se han observado como funciones del calor específico del suelo. Medidas de C, utilizando esta metodología y ante un rango variado de contenidos de humedad, sugirieron la idoneidad del método, aunque también se observaron importantes errores en contenidos bajos de humedad de hasta un 22%. La mejora del método requerirá otros modelos más precisos que tengan en cuenta el diámetro del cable, así como la posible influencia térmica del mismo. ABSTRACT There is an increasing need to make the most efficient use of water for irrigation. A good approach to make irrigation as efficient as possible is to monitor soil water content (θ) using soil moisture sensors. Although, there is a broad range of different sensors and technologies, currently, none of them can practically and accurately provide vertical and lateral moisture profiles spanning 0-1 m depth and 0.1-1,000 m lateral scales. In this regard, further research to fulfill the intermediate scale and to bridge single-point measurement with the broaden scales is still needed. This dissertation is based on the use of Fiber Optics with Distributed Temperature Sensing (FO-DTS), a novel approach which has been receiving growing interest in the last two decades. Specifically, we employ the so called Actively Heated Fiber Optic (AHFO) method, in which FO cables are employed as heat probe conductors by applying electricity to the stainless steel armoring jacket or an added conductor symmetrically positioned (wrapped) about the FO cable. AHFO is based on the classic Heated Pulsed Theory (HPP) which usually employs a heat probe conductor that approximates to an infinite line heat source which injects heat into the soil. Observation of the timing and magnitude of the thermal response to the energy input provide enough information to derive certain specific soil thermal characteristics such as the soil heat capacity, soil thermal conductivity or soil water content. These parameters can be estimated by capturing the soil thermal response (using a thermal sensor) adjacent to the heat source (the heating and the thermal sources are mounted together in the so called single heated pulsed probe (SHPP)), or separated at a certain distance, r (dual heated pulsed method (DHPP) This dissertation aims to test the feasibility of heated fiber optics to implement the HPP theory. Specifically, we focus on measuring soil water content (θ) and soil heat capacity (C) by employing two types of FO-DTS systems. The first one is located in an agricultural field in La Nava de Arévalo (Ávila, Spain) and employ the SHPP theory to estimate θ. The second one is developed in the laboratory using the procedures described in the DHPP theory, and focuses on estimating both C and θ. The SHPP theory can be implemented with actively heated fiber optics (AHFO) to obtain distributed measurements of soil water content (θ) by using reported soil thermal responses in Distributed Temperature Sensing (DTS) and with a soil-specific calibration relationship. However, most reported AHFO applications have been calibrated under laboratory homogeneous soil conditions, while inexpensive efficient calibration procedures useful in heterogeneous soils are lacking. In this PhD thesis, we employ the Hydrus 2D/3D code to define these soil-specific calibration curves. The model is then validated at a selected FO transect of the DTS installation. The model was able to predict the soil thermal response at specific locations of the fiber optic cable once the surrounding soil hydraulic and thermal properties were known. Results using electromagnetic moisture sensors at the same specific locations demonstrate the feasibility of the model to detect θ within an accuracy of 0.001 to 0.022 m3 m-3. Implementation of the Dual Heated Pulsed Probe (DPHP) theory for measurement of volumetric heat capacity (C) and water content (θ) with Distributed Temperature Sensing (DTS) heated fiber optic (FO) systems presents an unprecedented opportunity for environmental monitoring. We test the method using different combinations of FO cables and heat sources at a range of spacings in a laboratory setting. The amplitude and phase-shift in the heat signal with distance was found to be a function of the soil volumetric heat capacity (referred, here, to as Cs). Estimations of Cs at a range of θ suggest feasibility via responsiveness to the changes in θ (we observed a linear relationship in all FO combinations), though observed bias with decreasing soil water contents (up to 22%) was also reported. Optimization will require further models to account for the finite radius and thermal influence of the FO cables, employed here as “needle probes”. Also, consideration of the range of soil conditions and cable spacing and jacket configurations, suggested here to be valuable subjects of further study and development.
Resumo:
The Actively Heated Fiber Optic (AHFO) method is shown to be capable of measuring soil water content several times per hour at 0.25 m spacing along cables of multiple kilometers in length. AHFO is based on distributed temperature sensing (DTS) observation of the heating and cooling of a buried fiber-optic cable resulting from an electrical impulse of energy delivered from the steel cable jacket. The results presented were collected from 750 m of cable buried in three 240 m colocated transects at 30, 60, and 90 cm depths in an agricultural field under center pivot irrigation. The calibration curve relating soil water content to the thermal response of the soil to a heat pulse of 10 W m−1 for 1 min duration was developed in the lab. This calibration was found applicable to the 30 and 60 cm depth cables, while the 90 cm depth cable illustrated the challenges presented by soil heterogeneity for this technique. This method was used to map with high resolution the variability of soil water content and fluxes induced by the nonuniformity of water application at the surface.