25 resultados para Robotic Assisted Minimally Invasive Surgery (RAMIS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Surgical simulators are currently essential within any laparoscopic training program because they provide a low-stakes, reproducible and reliable environment to acquire basic skills. The purpose of this study is to determine the training learning curve based on different metrics corresponding to five tasks included in SINERGIA laparoscopic virtual reality simulator. Methods: Thirty medical students without surgical experience participated in the study. Five tasks of SINERGIA were included: Coordination, Navigation, Navigation and touch, Accurate grasping and Coordinated pulling. Each participant was trained in SINERGIA. This training consisted of eight sessions (R1–R8) of the five mentioned tasks and was carried out in two consecutive days with four sessions per day. A statistical analysis was made, and the results of R1, R4 and R8 were pair-wise compared with Wilcoxon signed-rank test. Significance is considered at P value <0.005. Results: In total, 84.38% of the metrics provided by SINERGIA and included in this study show significant differences when comparing R1 and R8. Metrics are mostly improved in the first session of training (75.00% when R1 and R4 are compared vs. 37.50% when R4 and R8 are compared). In tasks Coordination and Navigation and touch, all metrics are improved. On the other hand, Navigation just improves 60% of the analyzed metrics. Most learning curves show an improvement with better results in the fulfillment of the different tasks. Conclusions: Learning curves of metrics that assess the basic psychomotor laparoscopic skills acquired in SINERGIA virtual reality simulator show a faster learning rate during the first part of the training. Nevertheless, eight repetitions of the tasks are not enough to acquire all psychomotor skills that can be trained in SINERGIA. Therefore, and based on these results together with previous works, SINERGIA could be used as training tool with a properly designed training program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Auxetic materials (or metamaterials) are those with a negative Poisson ratio (NPR) and display the unexpected property of lateral expansion when stretched, as well as an equal and opposing densification when compressed. Such geometries are being progressively employed in the development of novel products, especially in the fields of intelligent expandable actuators, shape morphing structures and minimally invasive implantable devices. Although several auxetic and potentially auxetic geometries have been summarized in previous reviews and research, precise information regarding relevant properties for design tasks is not always provided. In this study we present a comparative study of two-dimensional and three-dimensional auxetic geometries carried out by means of computer-aided design and engineering tools (from now on CAD–CAE). The first part of the study is focused on the development of a CAD library of auxetics. Once the library is developed we simulate the behavior of the different auxetic geometries and elaborate a systematic comparison, considering relevant properties of these geometries, such as Poisson ratio(s), maximum volume or area reductions attainable and equivalent Young's modulus, hoping it may provide useful information for future designs of devices based on these interesting structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To propose an automated patient-specific algorithm for the creation of accurate and smooth meshes of the aortic anatomy, to be used for evaluating rupture risk factors of abdominal aortic aneurysms (AAA). Finite element (FE) analyses and simulations require meshes to be smooth and anatomically accurate, capturing both the artery wall and the intraluminal thrombus (ILT). The two main difficulties are the modeling of the arterial bifurcations, and of the ILT, which has an arbitrary shape that is conforming to the aortic wall.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is twofold: first, to develop a process to automatically create parametric models of the aorta that can adapt to any possible intraoperative deformation of the vessel. Second, it intends to provide the tools needed to perform this deformation in real time, by means of a non-rigid registration method. This dynamically deformable model will later be used in a VR-based surgery guidance system for aortic catheterism procedures, showing the vessel changes in real time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Auxetic materials (or metamaterials) have negative Poisson ratios (NPR) and display the unexpected properties of lateral expansion when stretched, and equal and opposing densification when compressed. Such auxetic materials are being used more frequently in the development of novel products, especially in the fields of intelligent expandable actuators, shape-morphing structures, and minimally invasive implantable devices. Although several micromanufacturing technologies have already been applied to the development of auxetic materials and devices, additional precision is needed to take full advantage of their special mechanical properties. In this study, we present a very promising approach for the development of auxetic materials and devices based on the use of deep reactive ion etching (DRIE). The process stands out for its precision and its potential applications to mass production. To our knowledge, it represents the first time this technology has been applied to the manufacture of auxetic materials with nanometric details. We take into account the present capabilities and challenges linked to the use of DRIE in the development of auxetic materials and auxetic-based devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assessment of diastolic chamber properties of the right ventricle by global fitting of pressure-volume data and conformational analysis of 3D + T echocardiographic sequences

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laparoscopic instrument tracking systems are an essential component in image-guided interventions and offer new possibilities to improve and automate objective assessment methods of surgical skills. In this study we present our system design to apply a third generation optical pose tracker (Micron- Tracker®) to laparoscopic practice. A technical evaluation of this design is performed in order to analyze its accuracy in computing the laparoscopic instrument tip position. Results show a stable fluctuation error over the entire analyzed workspace. The relative position errors are 1.776±1.675 mm, 1.817±1.762 mm, 1.854±1.740 mm, 2.455±2.164 mm, 2.545±2.496 mm, 2.764±2.342 mm, 2.512±2.493 mm for distances of 50, 100, 150, 200, 250, 300, and 350 mm, respectively. The accumulated distance error increases with the measured distance. The instrument inclination covered by the system is high, from 90 to 7.5 degrees. The system reports a low positional accuracy for the instrument tip.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. The aim of this paper was to establish the probable thermal difference between the beginning and the end of the anterior cruciate ligament (ACL) rehabilitation process after surgery. For this purpose thermograms from 25 ACL surgically operated patients (2 women, 23 men) were taken on the first and last day of a six-week rehabilitation program. A FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). The results showed significant temperature increases in the posterior thigh area between the first and the last week of the rehabilitation process probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and non-injured leg has increased from the first to the last day of the rehabilitation process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plant diseases represent a major economic and environmental problem in agriculture and forestry. Upon infection, a plant develops symptoms that affect different parts of the plant causing a significant agronomic impact. As many such diseases spread in time over the whole crop, a system for early disease detection can aid to mitigate the losses produced by the plant diseases and can further prevent their spread [1]. In recent years, several mathematical algorithms of search have been proposed [2,3] that could be used as a non-invasive, fast, reliable and cost-effective methods to localize in space infectious focus by detecting changes in the profile of volatile organic compounds. Tracking scents and locating odor sources is a major challenge in robotics, on one hand because odour plumes consists of non-uniform intermittent odour patches dispersed by the wind and on the other hand because of the lack of precise and reliable odour sensors. Notwithstanding, we have develop a simple robotic platform to study the robustness and effectiveness of different search algorithms [4], with respect to specific problems to be found in their further application in agriculture, namely errors committed in the motion and sensing and to the existence of spatial constraints due to land topology or the presence of obstacles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared thermography (IRT) is a safe and non-invasive tool used for examining physiological functions based on skin temperature (Tsk) control. Thermograms from 25 anterior cruciate ligament (ACL) surgically operated patients (2 female, 23 male) were taken with a FLIR infrared camera according to the protocol established by the International Academy of Clinical Thermology (IACT). This work consists of 4 studies. Studies 1 and 3 were related to establish the probable thermal difference among different moments of an ACL rupture after surgery: before starting the rehabilitation (P0), at the end of rehabilitation (P1) and 18 months from the end of rehabilitation (P2). For this purpose, on the other hand, studies 2 and 4 were related to establish the skin thermal difference (Tsk) between the injured and the non-injured leg in P0, P1 and P2. Results of the first study showed significant temperature increases in the posterior thigh area between P0 and P1 probably due to a compensatory mechanism. According to this, we can conclude that temperature of the posterior area of the injured and noninjured leg has increased from the first to the last day of the rehabilitation process. In the second study we found significant temperature differences between the injured and non-injured leg in both stages of rehabilitation (p<.01). On the one hand, the temperature of the injured leg is higher in the anterior view and the temperature of the non-injured leg is higher in the posterior view. By the time the patients had recovered from the reconstruction, thermal imbalances should have not been shown between symmetrical parts, but differences seemed to be still latent.. Study 3 shows that temperatures seem to be higher after a year and a half (P2) than in P1. Study 4 shows how thermal values 18 months later seemed to be normalized between both legs. No significant differences were found between the injured leg and the noninjured leg after one year and a half of the rehabilitation process. Considering results from Study 3 and 4 we can conclude that patients seemed to have recovered from a thermal point of view. The temperature in P2 was higher but symmetrical. RESUMEN La termografía infrarroja (IRT) es una herramienta segura y no invasiva utilizada para examinar funciones fisiológicas que se basan en el control de temperatura de la piel (Tsk). Termogramas de 25 pacientes intervenidos quirúrgicamente del ligamento cruzado anterior (LCA) (2 mujeres, 23 hombres) fueron tomadas con una cámara de infrarrojos FLIR de acuerdo con el protocolo establecido por la Academia Internacional de Termología Clínica (IACT). Este trabajo consiste en 4 estudios. Los estudios 1 y 3 describen la diferencia térmica entre los diferentes momentos tras la operación del ligamento cruzado anterior: antes de comenzar la rehabilitación (P0), al final de la rehabilitación (P1) y 18 meses tras finalizar la rehabilitación (P2). Por otra parte, los estudios 2 y 4 describen la diferencia de temperatura de la piel (Tsk) entre la pierna lesionada y la pierna no lesionada en P0, P1 y P2. Los resultados del primer estudio mostraron aumentos significativos de temperatura en la zona posterior de los muslos entre P0 y P1, probablemente debido a un mecanismo de compensación. De acuerdo con esto, se puede concluir que la temperatura de la zona posterior de la pierna lesionada y no lesionada se ha incrementado desde el primero hasta el último día del proceso de rehabilitación. En el segundo estudio se encontraron diferencias significativas de temperatura entre la pierna lesionada y no lesionada en ambas etapas de la rehabilitación (p<.01). Por un lado, la temperatura de la pierna lesionada es mayor en la vista anterior. Por otro lado, la temperatura de la pierna no lesionada es mayor en la vista posterior. Una vez que los pacientes se han recuperado de todo el proceso, no deberían existir desequilibrios térmicos entre partes simétricas del cuerpo, pero las diferencias todavía estaban latentes. El tercer estudio muestra que la temperatura es más alta en P2 que en P1. El cuarto estudio muestra cómo los valores térmicos entre ambas piernas en P2 se han normalizado entre ambas piernas. No se encontraron diferencias significativas entre la pierna lesionada y la pierna no lesionada después de 18 meses tras el proceso de rehabilitación. Considerando los resultados del studio 3 y 4, podemos concluir que se ha llegado a la recuperación total desde un punto de vista térmico. La temperatura es más elevada en P2 pero simétrica.