39 resultados para Power systems simulation
Resumo:
This paper presents results of the validity study of the use of MATLAB/Simulink synchronous-machine block for power-system stability studies. Firstly, the waveforms of the theoretical synchronous-generator short-circuit currents are described. Thereafter, the comparison between the currents obtained through the simulation model in the sudden short-circuit test, are compared to the theoretical ones. Finally, the factory tests of two commercial generating units are compared to the response of the synchronous generator simulation block during sudden short-circuit, set with the same real data, with satisfactory results. This results show the validity of the use of this generator block for power plant simulation.
Resumo:
I. GENERALIDADES 1.1. Introducción Entre los diversos tipos de perturbaciones eléctricas, los huecos de tensión son considerados el problema de calidad de suministro más frecuente en los sistemas eléctricos. Este fenómeno es originado por un aumento extremo de la corriente en el sistema, causado principalmente por cortocircuitos o maniobras inadecuadas en la red. Este tipo de perturbación eléctrica está caracterizado básicamente por dos parámetros: tensión residual y duración. Típicamente, se considera que el hueco se produce cuando la tensión residual alcanza en alguna de las fases un valor entre 0.01 a 0.9 pu y tiene una duración de hasta 60 segundos. Para un usuario final, el efecto más relevante de un hueco de tensión es la interrupción o alteración de la operación de sus equipos, siendo los dispositivos de naturaleza electrónica los principalmente afectados (p. ej. ordenador, variador de velocidad, autómata programable, relé, etc.). Debido al auge tecnológico de las últimas décadas y a la búsqueda constante de automatización de los procesos productivos, el uso de componentes electrónicos resulta indispensable en la actualidad. Este hecho, lleva a que los efectos de los huecos de tensión sean más evidentes para el usuario final, provocando que su nivel de exigencia de la calidad de energía suministrada sea cada vez mayor. De forma general, el estudio de los huecos de tensión suele ser abordado bajo dos enfoques: en la carga o en la red. Desde el punto de vista de la carga, se requiere conocer las características de sensibilidad de los equipos para modelar su respuesta ante variaciones súbitas de la tensión del suministro eléctrico. Desde la perspectiva de la red, se busca estimar u obtener información adecuada que permita caracterizar su comportamiento en términos de huecos de tensión. En esta tesis, el trabajo presentado se encuadra en el segundo aspecto, es decir, en el modelado y estimación de la respuesta de un sistema eléctrico de potencia ante los huecos de tensión. 1.2. Planteamiento del problema A pesar de que los huecos de tensión son el problema de calidad de suministro más frecuente en las redes, hasta la actualidad resulta complejo poder analizar de forma adecuada este tipo de perturbación para muchas compañías del sector eléctrico. Entre las razones más comunes se tienen: - El tiempo de monitorización puede llegar a ser de varios años para conseguir una muestra de registros de huecos estadísticamente válida. - La limitación de recursos económicos para la adquisición e instalación de equipos de monitorización de huecos. - El elevado coste operativo que implica el análisis de los datos de los medidores de huecos de tensión instalados. - La restricción que tienen los datos de calidad de energía de las compañías eléctricas. Es decir, ante la carencia de datos que permitan analizar con mayor detalle los huecos de tensión, es de interés de las compañías eléctricas y la academia poder crear métodos fiables que permitan profundizar en el estudio, estimación y supervisión de este fenómeno electromagnético. Los huecos de tensión, al ser principalmente originados por eventos fortuitos como los cortocircuitos, son el resultado de diversas variables exógenas como: (i) la ubicación de la falta, (ii) la impedancia del material de contacto, (iii) el tipo de fallo, (iv) la localización del fallo en la red, (v) la duración del evento, etc. Es decir, para plantear de forma adecuada cualquier modelo teórico sobre los huecos de tensión, se requeriría representar esta incertidumbre combinada de las variables para proveer métodos realistas y, por ende, fiables para los usuarios. 1.3. Objetivo La presente tesis ha tenido como objetivo el desarrollo diversos métodos estocásticos para el estudio, estimación y supervisión de los huecos de tensión en los sistemas eléctricos de potencia. De forma específica, se ha profundizado en los siguientes ámbitos: - En el modelado realista de las variables que influyen en la caracterización de los huecos. Esto es, en esta Tesis se ha propuesto un método que permite representar de forma verosímil su cuantificación y aleatoriedad en el tiempo empleando distribuciones de probabilidad paramétricas. A partir de ello, se ha creado una herramienta informática que permite estimar la severidad de los huecos de tensión en un sistema eléctrico genérico. - Se ha analizado la influencia la influencia de las variables de entrada en la estimación de los huecos de tensión. En este caso, el estudio se ha enfocado en las variables de mayor divergencia en su caracterización de las propuestas existentes. - Se ha desarrollado un método que permite estima el número de huecos de tensión de una zona sin monitorización a través de la información de un conjunto limitado de medidas de un sistema eléctrico. Para ello, se aplican los principios de la estadística Bayesiana, estimando el número de huecos de tensión más probable de un emplazamiento basándose en los registros de huecos de otros nudos de la red. - Plantear una estrategia para optimizar la monitorización de los huecos de tensión en un sistema eléctrico. Es decir, garantizar una supervisión del sistema a través de un número de medidores menor que el número de nudos de la red. II. ESTRUCTURA DE LA TESIS Para plantear las propuestas anteriormente indicadas, la presente Tesis se ha estructurado en seis capítulos. A continuación, se describen brevemente los mismos. A manera de capítulo introductorio, en el capítulo 1, se realiza una descripción del planteamiento y estructura de la presente tesis. Esto es, se da una visión amplia de la problemática a tratar, además de describir el alcance de cada capítulo de la misma. En el capítulo 2, se presenta una breve descripción de los fundamentos y conceptos generales de los huecos de tensión. Los mismos, buscan brindar al lector de una mejor comprensión de los términos e indicadores más empleados en el análisis de severidad de los huecos de tensión en las redes eléctricas. Asimismo, a manera de antecedente, se presenta un resumen de las principales características de las técnicas o métodos existentes aplicados en la predicción y monitorización óptima de los huecos de tensión. En el capítulo 3, se busca fundamentalmente conocer la importancia de las variables que determinen la frecuencia o severidad de los huecos de tensión. Para ello, se ha implementado una herramienta de estimación de huecos de tensión que, a través de un conjunto predeterminado de experimentos mediante la técnica denominada Diseño de experimentos, analiza la importancia de la parametrización de las variables de entrada del modelo. Su análisis, es realizado mediante la técnica de análisis de la varianza (ANOVA), la cual permite establecer con rigor matemático si la caracterización de una determinada variable afecta o no la respuesta del sistema en términos de los huecos de tensión. En el capítulo 4, se propone una metodología que permite predecir la severidad de los huecos de tensión de todo el sistema a partir de los registros de huecos de un conjunto reducido de nudos de dicha red. Para ello, se emplea el teorema de probabilidad condicional de Bayes, el cual calcula las medidas más probables de todo el sistema a partir de la información proporcionada por los medidores de huecos instalados. Asimismo, en este capítulo se revela una importante propiedad de los huecos de tensión, como es la correlación del número de eventos de huecos de tensión en diversas zonas de las redes eléctricas. En el capítulo 5, se desarrollan dos métodos de localización óptima de medidores de huecos de tensión. El primero, que es una evolución metodológica del criterio de observabilidad; aportando en el realismo de la pseudo-monitorización de los huecos de tensión con la que se calcula el conjunto óptimo de medidores y, por ende, en la fiabilidad del método. Como una propuesta alternativa, se emplea la propiedad de correlación de los eventos de huecos de tensión de una red para plantear un método que permita establecer la severidad de los huecos de todo el sistema a partir de una monitorización parcial de dicha red. Finalmente, en el capítulo 6, se realiza una breve descripción de las principales aportaciones de los estudios realizados en esta tesis. Adicionalmente, se describen diversos temas a desarrollar en futuros trabajos. III. RESULTADOS En base a las pruebas realizadas en las tres redes planteadas; dos redes de prueba IEEE de 24 y 118 nudos (IEEE-24 e IEEE-118), además del sistema eléctrico de la República del Ecuador de 357 nudos (EC-357), se describen los siguientes puntos como las observaciones más relevantes: A. Estimación de huecos de tensión en ausencia de medidas: Se implementa un método estocástico de estimación de huecos de tensión denominado PEHT, el cual representa con mayor realismo la simulación de los eventos de huecos de un sistema a largo plazo. Esta primera propuesta de la tesis, es considerada como un paso clave para el desarrollo de futuros métodos del presente trabajo, ya que permite emular de forma fiable los registros de huecos de tensión a largo plazo en una red genérica. Entre las novedades más relevantes del mencionado Programa de Estimación de Huecos de Tensión (PEHT) se tienen: - Considerar el efecto combinado de cinco variables aleatorias de entrada para simular los eventos de huecos de tensión en una pseudo-monitorización a largo plazo. Las variables de entrada modeladas en la caracterización de los huecos de tensión en el PEHT son: (i) coeficiente de fallo, (ii) impedancia de fallo, (iii) tipo de fallo, (iv) localización del fallo y (v) duración. - El modelado estocástico de las variables de entrada impedancia de fallo y duración en la caracterización de los eventos de huecos de tensión. Para la parametrización de las variables mencionadas, se realizó un estudio detallado del comportamiento real de las mismas en los sistemas eléctricos. Asimismo, se define la función estadística que mejor representa la naturaleza aleatoria de cada variable. - Considerar como variables de salida del PEHT a indicadores de severidad de huecos de uso común en las normativas, como es el caso de los índices: SARFI-X, SARFI-Curve, etc. B. Análisis de sensibilidad de los huecos de tensión: Se presenta un estudio causa-efecto (análisis de sensibilidad) de las variables de entrada de mayor divergencia en su parametrización entre las referencias relacionadas a la estimación de los huecos de tensión en redes eléctricas. De forma específica, se profundiza en el estudio de la influencia de la parametrización de las variables coeficiente de fallo e impedancia de fallo en la predicción de los huecos de tensión. A continuación un resumen de las conclusiones más destacables: - La precisión de la variable de entrada coeficiente de fallo se muestra como un parámetro no influyente en la estimación del número de huecos de tensión (SARFI-90 y SARFI-70) a largo plazo. Es decir, no se requiere de una alta precisión del dato tasa de fallo de los elementos del sistema para obtener una adecuada estimación de los huecos de tensión. - La parametrización de la variable impedancia de fallo se muestra como un factor muy sensible en la estimación de la severidad de los huecos de tensión. Por ejemplo, al aumentar el valor medio de esta variable aleatoria, se disminuye considerablemente la severidad reportada de los huecos en la red. Por otra parte, al evaluar el parámetro desviación típica de la impedancia de fallo, se observa una relación directamente proporcional de este parámetro con la severidad de los huecos de tensión de la red. Esto es, al aumentar la desviación típica de la impedancia de fallo, se evidencia un aumento de la media y de la variación interanual de los eventos SARFI-90 y SARFI-70. - En base al análisis de sensibilidad desarrollado en la variable impedancia de fallo, se considera muy cuestionable la fiabilidad de los métodos de estimación de huecos de tensión que omiten su efecto en el modelo planteado. C. Estimación de huecos de tensión en base a la información de una monitorización parcial de la red: Se desarrolla un método que emplea los registros de una red parcialmente monitorizada para determinar la severidad de los huecos de todo el sistema eléctrico. A partir de los casos de estudio realizados, se observa que el método implementado (PEHT+MP) posee las siguientes características: - La metodología propuesta en el PEHT+MP combina la teoría clásica de cortocircuitos con diversas técnicas estadísticas para estimar, a partir de los datos de los medidores de huecos instalados, las medidas de huecos de los nudos sin monitorización de una red genérica. - El proceso de estimación de los huecos de tensión de la zona no monitorizada de la red se fundamenta en la aplicación del teorema de probabilidad condicional de Bayes. Es decir, en base a los datos observados (los registros de los nudos monitorizados), el PEHT+MP calcula de forma probabilística la severidad de los huecos de los nudos sin monitorización del sistema. Entre las partes claves del procedimiento propuesto se tienen los siguientes puntos: (i) la creación de una base de datos realista de huecos de tensión a través del Programa de Estimación de Huecos de Tensión (PEHT) propuesto en el capítulo anterior; y, (ii) el criterio de máxima verosimilitud empleado para estimar las medidas de huecos de los nudos sin monitorización de la red evaluada. - Las predicciones de medidas de huecos de tensión del PEHT+MP se ven potenciadas por la propiedad de correlación de los huecos de tensión en diversas zonas de un sistema eléctrico. Esta característica intrínseca de las redes eléctricas limita de forma significativa la respuesta de las zonas fuertemente correlacionadas del sistema ante un eventual hueco de tensión. Como el PEHT+MP está basado en principios probabilísticos, la reducción del rango de las posibles medidas de huecos se ve reflejado en una mejor predicción de las medidas de huecos de la zona no monitorizada. - Con los datos de un conjunto de medidores relativamente pequeño del sistema, es posible obtener estimaciones precisas (error nulo) de la severidad de los huecos de la zona sin monitorizar en las tres redes estudiadas. - El PEHT+MP se puede aplicar a diversos tipos de indicadores de severidad de los huecos de tensión, como es el caso de los índices: SARFI-X, SARFI-Curve, SEI, etc. D. Localización óptima de medidores de huecos de tensión: Se plantean dos métodos para ubicar de forma estratégica al sistema de monitorización de huecos en una red genérica. La primera propuesta, que es una evolución metodológica de la localización óptima de medidores de huecos basada en el criterio de observabilidad (LOM+OBS); y, como segunda propuesta, un método que determina la localización de los medidores de huecos según el criterio del área de correlación (LOM+COR). Cada método de localización óptima de medidores propuesto tiene un objetivo concreto. En el caso del LOM+OBS, la finalidad del método es determinar el conjunto óptimo de medidores que permita registrar todos los fallos que originen huecos de tensión en la red. Por otro lado, en el método LOM+COR se persigue definir un sistema óptimo de medidores que, mediante la aplicación del PEHT+MP (implementado en el capítulo anterior), sea posible estimar de forma precisa las medidas de huecos de tensión de todo el sistema evaluado. A partir del desarrollo de los casos de estudio de los citados métodos de localización óptima de medidores en las tres redes planteadas, se describen a continuación las observaciones más relevantes: - Como la generación de pseudo-medidas de huecos de tensión de los métodos de localización óptima de medidores (LOM+OBS y LOM+COR) se obtienen mediante la aplicación del algoritmo PEHT, la formulación del criterio de optimización se realiza en base a una pseudo-monitorización realista, la cual considera la naturaleza aleatoria de los huecos de tensión a través de las cinco variables estocásticas modeladas en el PEHT. Esta característica de la base de datos de pseudo-medidas de huecos de los métodos LOM+OBS y LOM+COR brinda una mayor fiabilidad del conjunto óptimo de medidores calculado respecto a otros métodos similares en la bibliografía. - El conjunto óptimo de medidores se determina según la necesidad del operador de la red. Esto es, si el objetivo es registrar todos los fallos que originen huecos de tensión en el sistema, se emplea el criterio de observabilidad en la localización óptima de medidores de huecos. Por otra parte, si se plantea definir un sistema de monitorización que permita establecer la severidad de los huecos de tensión de todo el sistema en base a los datos de un conjunto reducido de medidores de huecos, el criterio de correlación resultaría el adecuado. De forma específica, en el caso del método LOM+OBS, basado en el criterio de observabilidad, se evidenciaron las siguientes propiedades en los casos de estudio realizados: - Al aumentar el tamaño de la red, se observa la tendencia de disminuir el porcentaje de nudos monitorizados de dicho sistema. Por ejemplo, para monitorizar los fallos que originan huecos en la red IEEE-24, se requiere monitorizar el 100\% de los nudos del sistema. En el caso de las redes IEEE-118 y EC-357, el método LOM+OBS determina que con la monitorización de un 89.5% y 65.3% del sistema, respectivamente, se cumpliría con el criterio de observabilidad del método. - El método LOM+OBS permite calcular la probabilidad de utilización del conjunto óptimo de medidores a largo plazo, estableciendo así un criterio de la relevancia que tiene cada medidor considerado como óptimo en la red. Con ello, se puede determinar el nivel de precisión u observabilidad (100%, 95%, etc.) con el cual se detectarían los fallos que generan huecos en la red estudiada. Esto es, al aumentar el nivel de precisión de detección de los fallos que originan huecos, se espera que aumente el número de medidores requeridos en el conjunto óptimo de medidores calculado. - El método LOM+OBS se evidencia como una técnica aplicable a todo tipo de sistema eléctrico (radial o mallado), el cual garantiza la detección de los fallos que originan huecos de tensión en un sistema según el nivel de observabilidad planteado. En el caso del método de localización óptima de medidores basado en el criterio del área de correlación (LOM+COR), las diversas pruebas realizadas evidenciaron las siguientes conclusiones: - El procedimiento del método LOM+COR combina los métodos de estimación de huecos de tensión de capítulos anteriores (PEHT y PEHT+MP) con técnicas de optimización lineal para definir la localización óptima de los medidores de huecos de tensión de una red. Esto es, se emplea el PEHT para generar los pseudo-registros de huecos de tensión, y, en base al criterio planteado de optimización (área de correlación), el LOM+COR formula y calcula analíticamente el conjunto óptimo de medidores de la red a largo plazo. A partir de la información registrada por este conjunto óptimo de medidores de huecos, se garantizaría una predicción precisa de la severidad de los huecos de tensión de todos los nudos del sistema con el PEHT+MP. - El método LOM+COR requiere un porcentaje relativamente reducido de nudos del sistema para cumplir con las condiciones de optimización establecidas en el criterio del área de correlación. Por ejemplo, en el caso del número total de huecos (SARFI-90) de las redes IEEE-24, IEEE-118 y EC-357, se calculó un conjunto óptimo de 9, 12 y 17 medidores de huecos, respectivamente. Es decir, solamente se requeriría monitorizar el 38\%, 10\% y 5\% de los sistemas indicados para supervisar los eventos SARFI-90 en toda la red. - El método LOM+COR se muestra como un procedimiento de optimización versátil, el cual permite reducir la dimensión del sistema de monitorización de huecos de redes eléctricas tanto radiales como malladas. Por sus características, este método de localización óptima permite emular una monitorización integral del sistema a través de los registros de un conjunto pequeño de monitores. Por ello, este nuevo método de optimización de medidores sería aplicable a operadores de redes que busquen disminuir los costes de instalación y operación del sistema de monitorización de los huecos de tensión. ABSTRACT I. GENERALITIES 1.1. Introduction Among the various types of electrical disturbances, voltage sags are considered the most common quality problem in power systems. This phenomenon is caused by an extreme increase of the current in the network, primarily caused by short-circuits or inadequate maneuvers in the system. This type of electrical disturbance is basically characterized by two parameters: residual voltage and duration. Typically, voltage sags occur when the residual voltage, in some phases, reaches a value between 0.01 to 0.9 pu and lasts up to 60 seconds. To an end user, the most important effect of a voltage sags is the interruption or alteration of their equipment operation, with electronic devices the most affected (e.g. computer, drive controller, PLC, relay, etc.). Due to the technology boom of recent decades and the constant search for automating production processes, the use of electronic components is essential today. This fact makes the effects of voltage sags more noticeable to the end user, causing the level of demand for a quality energy supply to be increased. In general, the study of voltage sags is usually approached from one of two aspects: the load or the network. From the point of view of the load, it is necessary to know the sensitivity characteristics of the equipment to model their response to sudden changes in power supply voltage. From the perspective of the network, the goal is to estimate or obtain adequate information to characterize the network behavior in terms of voltage sags. In this thesis, the work presented fits into the second aspect; that is, in the modeling and estimation of the response of a power system to voltage sag events. 1.2. Problem Statement Although voltage sags are the most frequent quality supply problem in electrical networks, thistype of disturbance remains complex and challenging to analyze properly. Among the most common reasons for this difficulty are: - The sag monitoring time, because it can take up to several years to get a statistically valid sample. - The limitation of funds for the acquisition and installation of sag monitoring equipment. - The high operating costs involved in the analysis of the voltage sag data from the installed monitors. - The restrictions that electrical companies have with the registered power quality data. That is, given the lack of data to further voltage sag analysis, it is of interest to electrical utilities and researchers to create reliable methods to deepen the study, estimation and monitoring of this electromagnetic phenomenon. Voltage sags, being mainly caused by random events such as short-circuits, are the result of various exogenous variables such as: (i) the number of faults of a system element, (ii) the impedance of the contact material, (iii) the fault type, (iv) the fault location, (v) the duration of the event, etc. That is, to properly raise any theoretical model of voltage sags, it is necessary to represent the combined uncertainty of variables to provide realistic methods that are reliable for users. 1.3. Objective This Thesis has been aimed at developing various stochastic methods for the study, estimation and monitoring of voltage sags in electrical power systems. Specifically, it has deepened the research in the following areas: - This research furthers knowledge in the realistic modeling of the variables that influence sag characterization. This thesis proposes a method to credibly represent the quantification and randomness of the sags in time by using parametric probability distributions. From this, a software tool was created to estimate the severity of voltage sags in a generic power system. - This research also analyzes the influence of the input variables in the estimation of voltage sags. In this case, the study has focused on the variables of greatest divergence in their characterization of the existing proposals. - A method was developed to estimate the number of voltage sags of an area without monitoring through the information of a limited set of sag monitors in an electrical system. To this end, the principles of Bayesian statistics are applied, estimating the number of sags most likely to happen in a system busbar based in records of other sag network busbars. - A strategy was developed to optimize the monitorization of voltage sags on a power system. Its purpose is to ensure the monitoring of the system through a number of monitors lower than the number of busbars of the network assessed. II. THESIS STRUCTURE To describe in detail the aforementioned proposals, this Thesis has been structured into six chapters. Below is are brief descriptions of them: As an introductory chapter, Chapter 1, provides a description of the approach and structure of this thesis. It presents a wide view of the problem to be treated, in addition to the description of the scope of each chapter. In Chapter 2, a brief description of the fundamental and general concepts of voltage sags is presented to provide to the reader a better understanding of the terms and indicators used in the severity analysis of voltage sags in power networks. Also, by way of background, a summary of the main features of existing techniques or methods used in the prediction and optimal monitoring of voltage sags is also presented. Chapter 3 essentially seeks to know the importance of the variables that determine the frequency or severity of voltage sags. To do this, a tool to estimate voltage sags is implemented that, through a predetermined set of experiments using the technique called Design of Experiments, discusses the importance of the parameters of the input variables of the model. Its analysis is interpreted by using the technique of analysis of variance (ANOVA), which provides mathematical rigor to establish whether the characterization of a particular variable affects the system response in terms of voltage sags or not. In Chapter 4, a methodology to predict the severity of voltage sags of an entire system through the sag logs of a reduced set of monitored busbars is proposed. For this, the Bayes conditional probability theorem is used, which calculates the most likely sag severity of the entire system from the information provided by the installed monitors. Also, in this chapter an important property of voltage sags is revealed, as is the correlation of the voltage sags events in several zones of a power system. In Chapter 5, two methods of optimal location of voltage sag monitors are developed. The first one is a methodological development of the observability criteria; it contributes to the realism of the sag pseudo-monitoring with which the optimal set of sag monitors is calculated and, therefore, to the reliability of the proposed method. As an alternative proposal, the correlation property of the sag events of a network is used to raise a method that establishes the sag severity of the entire system from a partial monitoring of the network. Finally, in Chapter 6, a brief description of the main contributions of the studies in this Thesis is detailed. Additionally, various themes to be developed in future works are described. III. RESULTS. Based on tests on the three networks presented, two IEEE test networks of 24 and 118 busbars (IEEE-24 and IEEE-118) and the electrical system of the Republic of Ecuador (EC-357), the following points present the most important observations: A. Estimation of voltage sags in the absence of measures: A stochastic estimation method of voltage sags, called PEHT, is implemented to represent with greater realism the long-term simulation of voltage sags events in a system. This first proposal of this thesis is considered a key step for the development of future methods of this work, as it emulates in a reliable manner the voltage sag long-term records in a generic network. Among the main innovations of this voltage sag estimation method are the following: - Consideration of the combined effect of five random input variables to simulate the events of voltage sags in long-term monitoring is included. The input variables modeled in the characterization of voltage sags on the PEHT are as follows: (i) fault coefficient, (ii) fault impedance, (iii) type of fault, (iv) location of the fault, and (v) fault duration. - Also included is the stochastic modeling of the input variables of fault impedance and duration in the characterization of the events of voltage sags. For the parameterization of these variables, a detailed study of the real behavior in power systems is developed. Also, the statistical function best suited to the random nature of each variable is defined. - Consideration of sag severity indicators used in standards as PEHT output variables, including such as indices as SARFI-X, SARFI-Curve, etc. B. Sensitivity analysis of voltage sags: A cause-effect study (sensitivity analysis) of the input variables of greatest divergence between reference parameterization related to the estimation of voltage sags in electrical networks is presented. Specifically, it delves into the study of the influence of the parameterization of the variables fault coefficient and fault impedance in the voltage sag estimation. Below is a summary of the most notable observations: - The accuracy of the input variable fault coefficient is shown as a non-influential parameter in the long-term estimation of the number of voltage sags (SARFI-90 and SARFI-70). That is, it does not require a high accuracy of the fault rate data of system elements for a proper voltage sag estimation. - The parameterization of the variable fault impedance is shown to be a very sensitive factor in the estimation of the voltage sag severity. For example, by increasing the average value of this random variable, the reported sag severity in the network significantly decreases. Moreover, in assessing the standard deviation of the fault impedance parameter, a direct relationship of this parameter with the voltage sag severity of the network is observed. That is, by increasing the fault impedance standard deviation, an increase of the average and the interannual variation of the SARFI-90 and SARFI-70 events is evidenced. - Based on the sensitivity analysis developed in the variable fault impedance, the omission of this variable in the voltage sag estimation would significantly call into question the reliability of the responses obtained. C. Voltage sag estimation from the information of a network partially monitored: A method that uses the voltage sag records of a partially monitored network for the sag estimation of all the power system is developed. From the case studies performed, it is observed that the method implemented (PEHT+MP) has the following characteristics: - The methodology proposed in the PEHT+MP combines the classical short-circuit theory with several statistical techniques to estimate, from data the of the installed sag meters, the sag measurements of unmonitored busbars of a generic power network. - The estimation process of voltage sags of the unmonitored zone of the network is based on the application of the conditional probability theorem of Bayes. That is, based on the observed data (monitored busbars records), the PEHT+MP calculates probabilistically the sag severity at unmonitored system busbars. Among the key parts of the proposed procedure are the following: (i) the creation of a realistic data base of voltage sags through of the sag estimation program (PEHT); and, (ii) the maximum likelihood criterion used to estimate the sag indices of system busbars without monitoring. - The voltage sag measurement estimations of PEHT+MP are potentiated by the correlation property of the sag events in power systems. This inherent characteristic of networks significantly limits the response of strongly correlated system zones to a possible voltage sag. As the PEHT+MP is based on probabilistic principles, a reduction of the range of possible sag measurements is reflected in a better sag estimation of the unmonitored area of the power system. - From the data of a set of monitors representing a relatively small portion of the system, to obtain accurate estimations (null error) of the sag severity zones without monitoring is feasible in the three networks studied. - The PEHT+MP can be applied to several types of sag indices, such as: SARFI-X, SARFI-Curve, SEI, etc. D. Optimal location of voltage sag monitors in power systems: Two methods for strategically locating the sag monitoring system are implemented for a generic network. The first proposal is a methodological development of the optimal location of sag monitors based on the observability criterion (LOM + OBS); the second proposal is a method that determines the sag monitor location according to the correlation area criterion (LOM+COR). Each proposed method of optimal location of sag monitors has a specific goal. In the case of LOM+OBS, the purpose of the method is to determine the optimal set of sag monitors to record all faults that originate voltage sags in the network. On the other hand, the LOM+COR method attempts to define the optimal location of sag monitors to estimate the sag indices in all the assessed network with the PEHT+MP application. From the development of the case studies of these methods of optimal location of sag monitors in the three networks raised, the most relevant observations are described below: - As the generation of voltage sag pseudo-measurements of the optimal location methods (LOM+OBS and LOM+COR) are obtained by applying the algorithm PEHT, the formulation of the optimization criterion is performed based on a realistic sag pseudo-monitoring, which considers the random nature of voltage sags through the five stochastic variables modeled in PEHT. This feature of the database of sag pseudo-measurements of the LOM+OBS and LOM+COR methods provides a greater reliability of the optimal set of monitors calculated when compared to similar methods in the bibliography. - The optimal set of sag monitors is determined by the network operator need. That is, if the goal is to record all faults that originate from voltage sags in the system, the observability criterion is used to determine the optimal location of sag monitors (LOM+OBS). Moreover, if the objective is to define a monitoring system that allows establishing the sag severity of the system from taken from information based on a limited set of sag monitors, the correlation area criterion would be appropriate (LOM+COR). Specifically, in the case of the LOM+OBS method (based on the observability criterion), the following properties were observed in the case studies: - By increasing the size of the network, there was observed a reduction in the percentage of monitored system busbars required. For example, to monitor all the faults which cause sags in the IEEE-24 network, then 100% of the system busbars are required for monitoring. In the case of the IEEE-118 and EC-357 networks, the method LOM+OBS determines that with monitoring 89.5 % and 65.3 % of the system, respectively, the observability criterion of the method would be fulfilled. - The LOM+OBS method calculates the probability of using the optimal set of sag monitors in the long term, establishing a relevance criterion of each sag monitor considered as optimal in the network. With this, the level of accuracy or observability (100%, 95%, etc.) can be determined, with which the faults that caused sags in the studied network are detected. That is, when the accuracy level for detecting faults that cause sags in the system is increased, a larger number of sag monitors is expected when calculating the optimal set of monitors. - The LOM + OBS method is demonstrated to be a technique applicable to any type of electrical system (radial or mesh), ensuring the detection of faults that cause voltage sags in a system according to the observability level raised. In the case of the optimal localization of sag monitors based on the criterion of correlation area (LOM+COR), several tests showed the following conclusions: - The procedure of LOM+COR method combines the implemented algorithms of voltage sag estimation (PEHT and PEHT+MP) with linear optimization techniques to define the optimal location of the sag monitors in a network. That is, the PEHT is used to generate the voltage sag pseudo-records, and, from the proposed optimization criterion (correlation area), the LOM+COR formulates and analytically calculates the optimal set of sag monitors of the network in the long term. From the information recorded by the optimal set of sag monitors, an accurate prediction of the voltage sag severity at all the busbars of the system is guaranteed with the PEHT+MP. - The LOM + COR method is shown to be a versatile optimization procedure, which reduces the size of the sag monitoring system both at radial as meshed grids. Due to its characteristics, this optimal location method allows emulation of complete system sag monitoring through the records of a small optimal set of sag monitors. Therefore, this new optimization method would be applicable to network operators that looks to reduce the installation and operation costs of the voltage sag monitoring system.
Resumo:
This report analyzes the basis of hydrogen and power integration strategies, by using water electrolysis processes as a means of flexible energy storage at large scales. It is a prospective study, where the scope is to describe the characteristics of current power systems (like the generation technologies, load curves and grid constraints), and define future scenarios of hydrogen for balancing the electrical grids, considering the efficiency, economy and easiness of operations. We focus in the "Spanish case", which is a good example for planning the transition from a power system holding large reserve capacities, high penetration of renewable energies and limited interconnections, to a more sustainable energy system being capable to optimize the volumes, the regulation modes, the utilization ratios and the impacts of the installations. Thus, we explore a novel aspect of the "hydrogen economy" which is based in the potentials of existing power systems and the properties of hydrogen as energy carrier, by considering the electricity generation and demand globally and determining the optimal size and operation of the hydrogen production processes along the country; e.g. the cost production of hydrogen becomes viable for a base-load scenario with 58 TWh/year of power surplus at 0.025 V/kWh, and large number electrolyzer plants (50 MW) running in variable mode (1-12 kA/m2)
Resumo:
The purpose of this work is to propose a structure for simulating power systems using behavioral models of nonlinear DC to DC converters implemented through a look-up table of gains. This structure is specially designed for converters whose output impedance depends on the load current level, e.g. quasi-resonant converters. The proposed model is a generic one whose parameters can be obtained by direct measuring the transient response at different operating points. It also includes optional functionalities for modeling converters with current limitation and current sharing in paralleling characteristics. The pusposed structured also allows including aditional characteristics of the DC to DC converter as the efficency as a function of the input voltage and the output current or overvoltage and undervoltage protections. In addition, this proposed model is valid for overdamped and underdamped situations.
Resumo:
This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.
Resumo:
The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.
Resumo:
A three-phase transformer with flat conductor layers is proposed in this article. This arrangement is used for high current density transformers. Cost effectiveness in planar magnetic are related with the optimization in the number of layers in each winding. This fact takes more relevance for the medium and high power three-phase transformers where the number of parallels to achieve the required DCR is increased. The proposed method allows the use of off-the-shell core shapes that are used for single phase transformers. Cost impact is significant and design implications become more flexible. The proposed solution has been validated and compared using the conventional and the proposed methodologies to design a high power (20 kW) transformer.
Resumo:
The rotation maize and dry bean provides the main food supply of smallholder farmers in Honduras. Crop model assessment of climate change impacts (2070?2099 compared to a 1961?1990 baseline) on a maize?dry bean rotation for several sites across a range of climatic zones and elevations in Honduras. Low productivity systems, together with an uncertain future climate, pose a high level of risk for food security. The cropping systems simulation dynamic model CropSyst was calibrated and validated upon field trail site at Zamorano, then run with baseline and future climate scenarios based upon general circulation models (GCM) and the ClimGen synthetic daily weather generator. Results indicate large uncertainty in crop production from various GCM simulations and future emissions scenarios, but generally reduced yields at low elevations by 0 % to 22 % in suitable areas for crop production and increased yield at the cooler, on the hillsides, where farming needs to reduce soil erosion with conservation techniques. Further studies are needed to investigate strategies to reduce impacts and to explore adaptation tactics.
Resumo:
Las redes inalámbricas están experimentando un gran crecimiento en el campo de la instrumentación electrónica. En concreto las redes de sensores inalámbricas (WSN de Wireless Sensor Network) suponen la opción más ventajosa para su empleo en la instrumentación electrónica ya que sus principales características se acoplan perfectamente a las necesidades. Las WSN permiten la utilización de un número relativamente alto de nodos, están orientadas a sistemas de bajo consumo y funcionamiento con baterías y poseen un ancho de banda adecuado para las necesidades de la instrumentación electrónica. En este proyecto fin de carrera se ha realizado un estudio de las tecnologías inalámbricas disponibles, se han comparado y se ha elegido la tecnología ZigBeeTM por considerarse la más adecuada y la que más se ajusta a las necesidades descritas. En el desarrollo de mi vida profesional se han conectado dos campos teóricamente distantes como son la instrumentación electrónica y la ingeniería civil. En este proyecto se hace una descripción de la instrumentación que se utiliza para controlar estructuras como presas, túneles y puentes y se proponen casos prácticos en los que las redes WSN aportan valor añadido a instrumentación actual y a los sistemas de comunicaciones utilizados. Se definen tanto los sistemas de comunicaciones utilizados actualmente como una serie de sensores utilizados para medir los principales parámetros a controlar en una obra civil. Por último se ha desarrollado una aplicación de prueba de una red ZigBeeTM basada en equipos comerciales del fabricante Digi. consiste en una aplicación desarrollada en entorno web que maneja de forma remota, a través de Internet, las entradas y salidas digitales y analógicas de los nodos que forman la red. Se forma una red ZigBeeTM con un coordinador, un router y un dispositivo final. El Coordinador está integrado en un Gateway que permite acceder a la red ZigBeeTM a través de internet y conocer el estado de los nodos que forman la red. Con los comandos adecuados se puede leer el estado de las entradas y salidas analógicas y digitales y cambiar el estado de una salida digital. ABSTRACT. Wireless networks are experiencing tremendous growth in the field of electronic instrumentation. In particular wireless sensor networks represent the most advantageous for use in electronic instrumentation since its main characteristics fit perfectly to the needs. The WSN allow the use of a relatively large number of nodes, are aimed at low-power systems and battery operation and have an adequate bandwidth for the needs of electronic instrumentation. In this project has made a study of available wireless technologies have been compared and chosen ZigBeeTM technology was considered the most appropriate to the needs described. In the course of my professional life have connected two fields are theoretically distant as electronic instrumentation and civil engineering. In this project, there is a description of the instrumentation used to control structures such as dams, tunnels and bridges and proposes practical cases in which WSN networks add value to current instrumentation and communications systems used. There are defined as communications systems now being used as a set of sensors used to measure the main parameters to be controlled in a civil structure. Finally, I have developed a test application based ZigBeeTM networking equipment maker Digi trading. It consists of a Web-based application developed to manage remotely, via the Internet, the digital and analog inputs and outputs nodes forming the network. ZigBeeTM It forms a network with a coordinator, router and end device. The Coordinator is built into a gateway that allows access to the ZigBeeTM network through internet and know the status of the nodes forming the network. With the appropriate command can read the status of the digital inputs and outputs and change the state of a digital output.
Resumo:
La Diabetes Mellitus se define como el trastorno del metabolismo de los carbohidratos, resultante de una producción insuficiente o nula de insulina en las células beta del páncreas, o la manifestación de una sensibilidad reducida a la insulina por parte del sistema metabólico. La diabetes tipo 1 se caracteriza por la nula producción de insulina por la destrucción de las células beta del páncreas. Si no hay insulina en el torrente sanguíneo, la glucosa no puede ser absorbida por las células, produciéndose un estado de hiperglucemia en el paciente, que a medio y largo plazo si no es tratado puede ocasionar severas enfermedades, conocidos como síndromes de la diabetes. La diabetes tipo 1 es una enfermedad incurable pero controlable. La terapia para esta enfermedad consiste en la aplicación exógena de insulina con el objetivo de mantener el nivel de glucosa en sangre dentro de los límites normales. Dentro de las múltiples formas de aplicación de la insulina, en este proyecto se usará una bomba de infusión, que unida a un sensor subcutáneo de glucosa permitirá crear un lazo de control autónomo que regule la cantidad optima de insulina aplicada en cada momento. Cuando el algoritmo de control se utiliza en un sistema digital, junto con el sensor subcutáneo y bomba de infusión subcutánea, se conoce como páncreas artificial endocrino (PAE) de uso ambulatorio, hoy día todavía en fase de investigación. Estos algoritmos de control metabólico deben de ser evaluados en simulación para asegurar la integridad física de los pacientes, por lo que es necesario diseñar un sistema de simulación mediante el cual asegure la fiabilidad del PAE. Este sistema de simulación conecta los algoritmos con modelos metabólicos matemáticos para obtener una visión previa de su funcionamiento. En este escenario se diseñó DIABSIM, una herramienta desarrollada en LabViewTM, que posteriormente se trasladó a MATLABTM, y basada en el modelo matemático compartimental propuesto por Hovorka, con la que poder simular y evaluar distintos tipos de terapias y reguladores en lazo cerrado. Para comprobar que estas terapias y reguladores funcionan, una vez simulados y evaluados, se tiene que pasar a la experimentación real a través de un protocolo de ensayo clínico real, como paso previo al PEA ambulatorio. Para poder gestionar este protocolo de ensayo clínico real para la verificación de los algoritmos de control, se creó una interfaz de usuario a través de una serie de funciones de simulación y evaluación de terapias con insulina realizadas con MATLABTM (GUI: Graphics User Interface), conocido como Entorno de Páncreas artificial con Interfaz Clínica (EPIC). EPIC ha sido ya utilizada en 10 ensayos clínicos de los que se han ido proponiendo posibles mejoras, ampliaciones y/o cambios. Este proyecto propone una versión mejorada de la interfaz de usuario EPIC propuesta en un proyecto anterior para gestionar un protocolo de ensayo clínico real para la verificación de algoritmos de control en un ambiente hospitalario muy controlado, además de estudiar la viabilidad de conectar el GUI con SimulinkTM (entorno gráfico de Matlab de simulación de sistemas) para su conexión con un nuevo simulador de pacientes aprobado por la JDRF (Juvenil Diabetes Research Foundation). SUMMARY The diabetes mellitus is a metabolic disorder of carbohydrates, as result of an insufficient or null production of insulin in the beta cellules of pancreas, or the manifestation of a reduced sensibility to the insulin from the metabolic system. The type 1 diabetes is characterized for a null production of insulin due to destruction of the beta cellules. Without insulin in the bloodstream, glucose can’t be absorbed by the cellules, producing a hyperglycemia state in the patient and if pass a medium or long time and is not treated can cause severe disease like diabetes syndrome. The type 1 diabetes is an incurable disease but controllable one. The therapy for this disease consists on the exogenous insulin administration with the objective to maintain the glucose level in blood within the normal limits. For the insulin administration, in this project is used an infusion pump, that permit with a subcutaneous glucose sensor, create an autonomous control loop that regulate the optimal insulin amount apply in each moment. When the control algorithm is used in a digital system, with the subcutaneous senor and infusion subcutaneous pump, is named as “Artificial Endocrine Pancreas” for ambulatory use, currently under investigate. These metabolic control algorithms should be evaluates in simulation for assure patients’ physical integrity, for this reason is necessary to design a simulation system that assure the reliability of PAE. This simulation system connects algorithms with metabolic mathematics models for get a previous vision of its performance. In this scenario was created DIABSIMTM, a tool developed in LabView, that later was converted to MATLABTM, and based in the compartmental mathematic model proposed by Hovorka that could simulate and evaluate several different types of therapy and regulators in closed loop. To check the performance of these therapies and regulators, when have been simulated and evaluated, will be necessary to pass to real experimentation through a protocol of real clinical test like previous step to ambulatory PEA. To manage this protocol was created an user interface through the simulation and evaluation functions od therapies with insulin realized with MATLABTM (GUI: Graphics User Interface), known as “Entorno de Páncreas artificial con Interfaz Clínica” (EPIC).EPIC have been used in 10 clinical tests which have been proposed improvements, adds and changes. This project proposes a best version of user interface EPIC proposed in another project for manage a real test clinical protocol for checking control algorithms in a controlled hospital environment and besides studying viability to connect the GUI with SimulinkTM (Matlab graphical environment in systems simulation) for its connection with a new patients simulator approved for the JDRF (Juvenil Diabetes Research Foundation).
Resumo:
Nuevas aplicaciones tecnológicas y científicas mediante amarras electrodinámicas son analizadas para misiones planetarias. i) Primero, se considera un conjunto de amarras cilíndricas en paralelo (veleros electrosolares) para una misión interplanetaria. Los iones provenientes del viento solar son repelidos por el alto potencial de dichas amarras generando empuje sobre el velero. Para conocer el intercambio de momento que provocan los iones sobre las amarras se ha considerado un modelo de potencial estacionario. Se ha analizado la transferencia orbital de la Tierra a Júpiter siguiendo un método de optimización de trayectoria indirecto. ii) Una vez que el velero se encuentra cerca de Júpiter, se ha considerado el despliegue de una amarra para diferentes objetivos científicos. iia) Una amarra podría ser utilizada para diagnóstico de plasmas, al ser una fuente efectiva de ondas, y también como un generador de auroras artificiales. Una amarra conductora que orbite en la magnetosfera jovial es capaz de producir ondas. Se han analizado las diferentes ondas radiadas por un conductor por el que circula una corriente constante que sigue una órbita polar de alta excentricidad y bajo apoápside, como ocurre en la misión Juno de la NASA. iib) Además, se ha estudiado una misión tentativa que sigue una órbita ecuatorial (LJO) por debajo de los intensos cinturones de radiación. Ambas misiones requiren potencia eléctrica para los sistemas de comunicación e instrumentos científicos. Las amarras pueden generar potencia de manera más eficiente que otros sistemas que utlizan paneles solares o sistemas de potencia de radioisótopos (RPS). La impedancia de radiación es necesaria para determinar la corriente que circula por todo el circuito de la amarra. En un modelo de plasma frío, la radiación ocurre principalmente en los modos de Alfven y magnetosónica rápida, mostrando un elevado índice de refracción. Se ha estudiado la impedancia de radiación en amarras con recubrimiento aislante para los dos modos de radiación y cada una de las misiones. A diferencia del caso ionosférico terrestre, la baja densidad y el intenso campo magnético que aparecen en el entorno de Júpiter consiguen que la girofrecuencia de los electrones sea mucho mayor que la frecuencia del plasma; esto hace que el espectro de potencia para cada modo se modifique substancialmente, aumentando la velocidad de Alfven. Se ha estimado también la impedancia de radiación para amarras sin aislante conductor. En la misión LJO, un vehículo espacial bajando lentamente la altitud de su órbita permitiría estudiar la estructura del campo magnético y composición atmosférica para entender la formación, evolución, y estructura de Júpiter. Adicionalmente, si el contactor (cátodo) se apaga, se dice que la amarra flota eléctricamente, permitiendo emisión de haz de electrones que generan auroras. El continuo apagado y encendido produce pulsos de corriente dando lugar a emisiones de señales, que pueden ser utilizadas para diagnóstico del plasma jovial. En Órbita Baja Jovial, los iones que impactan contra una amarra polarizada negativamente producen electrones secundarios, que, viajando helicoidalmente sobre las líneas de campo magnético de Júpiter, son capaces de alcanzar su atmósfera más alta, y, de esta manera, generar auroras. Se han identificado cuáles son las regiones donde la amarra sería más eficiente para producir auroras. iic) Otra aplicación científica sugerida para la misión LJO es la detección de granos cargados que orbitan cerca de Júpiter. Los electrones de alta energía en este ambiente pueden ser modelados por una distribucción no Maxwelliana conocida como distribución kappa. En escenarios con plasmas complejos, donde los campos eléctricos en Júpiter pueden acelerar las cargas hasta velocidades que superen la velocidad térmica, este tipo de distribuciones son muy útiles. En este caso las colas de las distribuciones de electrones siguen una ley de potencias. Se han estudiado las fluctuaciones de granos cargados para funciones de distribución kappa. iii) La tesis concluye con el análisis para deorbitar satélites con amarras electrodinámicas que siguen una Órbita Baja Terrestre (LEO). Una amarra debe presentar una baja probabilidad de corte por pequeño debris y además debe ser suficientemente ligero para que el cociente entre la masa de la amarra y el satélite sea muy pequeño. En este trabajo se estiman las medidas de la longitud, anchura y espesor que debe tener una amarra para minimizar el producto de la probabilidad de corte por el cociente entre las masas de la amarra y el satélite. Se presentan resultados preliminares del diseño de una amarra con forma de cinta para deorbitar satélites relativamente ligeros como Cryosat y pesados como Envisat. Las misiones espaciales a planetas exteriores y en el ámbito terrestre plantean importantes retos científico-tecnológicos que deben ser abordados y solucionados. Por ello, desde el inicio de la era espacial se han diseñando novedosos métodos propulsivos, sistemas de guiado, navegación y control más robustos, y nuevos materiales para mejorar el rendimiento de los vehículos espaciales (SC). En un gran número de misiones interplanetarias y en todas las misiones a planetas exteriores se han empleado sistemas de radioisótopos (RPS) para generar potencia eléctrica en los vehículos espaciales y en los rovers de exploración. Estos sistemas emplean como fuente de energía el escaso y costoso plutonio-238. La NASA, por medio de un informe de la National Academy of Science (5 de Mayo del 2009), expresó una profunda preocupación por la baja cantidad de plutonio almacenado, insuficiente para desarrollar todas las misiones de exploración planetaria planeadas en el futuro [81, 91]. Esta circustancia ha llevado a dicha Agencia tomar la decisión de limitar el uso de estos sistemas RPS en algunas misiones de especial interés científico y una recomendación de alta prioridad para que el Congreso de los EEUU apruebe el reestablecimiento de la producción de plutonio-238, -son necesarios cerca de 5 kg de este material radiactivo al año-, para salvaguardar las misiones que requieran dichos sistemas de potencia a partir del año 2018. Por otro lado, la Agencia estadounidense ha estado considerando el uso de fuentes de energía alternativa; como la fisión nuclear a través del ambicioso proyecto Prometheus, para llevar a cabo una misión de exploración en el sistema jovial (JIMO). Finalmente, dicha misión fue desestimada por su elevado coste. Recientemente se han estado desarrollando sistemas que consigan energía a través de los recursos naturales que nos aporta el Sol, mediante paneles solares -poco eficientes para misiones a planetas alejados de la luz solar-. En este contexto, la misión JUNO del programa Nuevas Fronteras de la NASA, cuyo lanzamiento fue realizado con éxito en Agosto de 2011, va a ser la primera misión equipada con paneles solares que sobrevolará Júpiter en el 2015 siguiendo una órbita polar. Anteriormente se habían empleado los antes mencionados RPS para las misiones Pioneer 10,11, Voyager 1,2, Ulysses, Cassini-Huygens y Galileo (todas sobrevuelos excepto Galileo). Dicha misión seguirá una órbita elíptica de alta excentricidad con un periápside muy cercano a Júpiter, y apoápside lejano, evitando que los intensos cinturones de radiación puedan dañar los instrumentos de navegación y científicos. Un tether o amarra electrodinámica es capaz de operar como sistema propulsivo o generador de potencia, pero también puede ser considerado como solución científicotecnológica en misiones espaciales tanto en LEO (Órbita Baja Terrestre) como en planetas exteriores. Siguiendo una perspectiva histórica, durante las misiones terrestres TSS-1 (1992) y TSS-1R (1996) se emplearon amarras estandard con recubrimiento aislante en toda su longitud, aplicando como terminal anódico pasivo un colector esférico para captar electrones. En una geometría alternativa, propuesta por J. R. Sanmartín et al. (1993) [93], se consideró dejar la amarra sin recubrimiento aislante (“bare tether”), y sin colector anódico esférico, de forma que recogiera electrones a lo largo del segmento que resulta polarizado positivo, como si se tratara de una sonda de Langmuir de gran longitud. A diferencia de la amarra estandard, el “bare tether” es capaz de recoger electrones a lo largo de una superficie grande ya que este segmento es de varios kilómetros de longitud. Como el radio de la amarra es del orden de la longitud de Debye y pequeño comparado con el radio de Larmor de los electrones, permite una recolección eficiente de electrones en el régimen OML (Orbital Motion Limited) de sondas de Langmuir. La corriente dada por la teoría OML varía en función del perímetro y la longitud. En el caso de una cinta delgada, el perímetro depende de la anchura, que debe ser suficientemente grande para evitar cortes producidos por debris y micrometeoritos, y suficientemente pequeño para que la amarra funcione en dicho régimen [95]. En el experimento espacial TSS-1R mencionado anteriormente, se identificó una recolección de corriente más elevada que la que predecía el modelo teórico de Parker- Murphy, debido posiblemente a que se utilizaba un colector esférico de radio bastante mayor que la longitud de Debye [79]. En el caso de una amarra “bare”, que recoge electrones a lo largo de gran parte de su longitud, se puede producir un fenómeno conocido como atrapamiento adiabático de electrones (adiabatic electron trapping) [25, 40, 60, 73, 74, 97]. En el caso terrestre (LEO) se da la condición mesotérmica en la que la amarra se mueve con una velocidad muy superior a la velocidad térmica de los iones del ambiente y muy inferior a la velocidad térmica de los electrones. J. Laframboise y L. Parker [57] mostraron que, para una función de distribución quasi-isotrópica, la densidad de electrones debe entonces ser necesariamente inferior a la densidad ambiente. Por otra parte, debido a su flujo hipersónico y a la alta polarización positiva de la amarra, la densidad de los iones es mayor que la densidad ambiente en una vasta región de la parte “ram” del flujo, violando la condición de cuasi-neutralidad,-en una región de dimensión mayor que la longitud de Debye-. La solución a esta paradoja podría basarse en el atrapamiento adiabático de electrones ambiente en órbitas acotadas entorno al tether. ABSTRACT New technological and scientific applications by electrodynamic tethers for planetary missions are analyzed: i) A set of cylindrical, parallel tethers (electric solar sail or e-sail) is considered for an interplanetary mission; ions from the solar wind are repelled by the high potential of the tether, providing momentum to the e-sail. An approximated model of a stationary potential for a high solar wind flow is considered. With the force provided by a negative biased tether, an indirect method for the optimization trajectory of an Earth-to-Jupiter orbit transfer is analyzed. ii) The deployment of a tether from the e-sail allows several scientific applications in Jupiter. iia) It might be used as a source of radiative waves for plasma diagnostics and artificial aurora generator. A conductive tether orbiting in the Jovian magnetosphere produces waves. Wave radiation by a conductor carrying a steady current in both a polar, highly eccentric, low perijove orbit, as in NASA’s Juno mission, and an equatorial low Jovian orbit (LJO) mission below the intense radiation belts, is considered. Both missions will need electric power generation for scientific instruments and communication systems. Tethers generate power more efficiently than solar panels or radioisotope power systems (RPS). The radiation impedance is required to determine the current in the overall tether circuit. In a cold plasma model, radiation occurs mainly in the Alfven and fast magnetosonic modes, exhibiting a large refraction index. The radiation impedance of insulated tethers is determined for both modes and either mission. Unlike the Earth ionospheric case, the low-density, highly magnetized Jovian plasma makes the electron gyrofrequency much larger than the plasma frequency; this substantially modifies the power spectrum for either mode by increasing the Alfven velocity. An estimation of the radiation impedance of bare tethers is also considered. iib) In LJO, a spacecraft orbiting in a slow downward spiral under the radiation belts would allow determining magnetic field structure and atmospheric composition for understanding the formation, evolution, and structure of Jupiter. Additionally, if the cathodic contactor is switched off, a tether floats electrically, allowing e-beam emission that generate auroras. On/off switching produces bias/current pulses and signal emission, which might be used for Jovian plasma diagnostics. In LJO, the ions impacting against the negative-biased tether do produce secondary electrons, which racing down Jupiter’s magnetic field lines, reach the upper atmosphere. The energetic electrons there generate auroral effects. Regions where the tether efficiently should produce secondary electrons are analyzed. iic) Other scientific application suggested in LJO is the in-situ detection of charged grains. Charged grains naturally orbit near Jupiter. High-energy electrons in the Jovian ambient may be modeled by the kappa distribution function. In complex plasma scenarios, where the Jovian high electric field may accelerate charges up superthermal velocities, the use of non-Maxwellian distributions should be considered. In these cases, the distribution tails fit well to a power-law dependence for electrons. Fluctuations of the charged grains for non-Mawellian distribution function are here studied. iii) The present thesis is concluded with the analysis for de-orbiting satellites at end of mission by electrodynamic tethers. A de-orbit tether system must present very small tether-to-satellite mass ratio and small probability of a tether cut by small debris too. The present work shows how to select tape dimensions so as to minimize the product of those two magnitudes. Preliminary results of tape-tether design are here discussed to minimize that function. Results for de-orbiting Cryosat and Envisat are also presented.
Resumo:
Juno, the second mission in the NASA New Frontiers Program, will both be a polar Jovian orbiter, and use solar arrays for power, moving away from previous use of radioisotope power systems (RPSs) in spite of the weak solar light reaching Jupiter. The power generation at Jupiter is critical, and a conductive tether could be an alternative source of power. A current-carrying tether orbiting in a magnetized ionosphere/plasmasphere will radiate waves. A magnitude of interest for both power generation and signal emission is the wave impedance. Jupiter has the strongest magnetic field in the Solar Planetary System and its plasma density is low everywhere. This leads to an electron plasma frequency smaller than the electron cyclotron frequency, and a high Alfven velocity. Unlike the low Earth orbit (LEO) case, the electron skin depth and the characteristic size of plasma contactors affect the Alfven impedance.
Resumo:
Wave radiation by a conductor carrying a steady current in both a polar, highly eccentric, low perijove orbit, as in NASA's planned Juno mission, and an equatorial low Jovian orbit (LJO) mission below the intense radiation belts, is considered. Both missions will need electric power generation for scientific instruments and communication systems. Tethers generate power more efficiently than solar panels or radioisotope power systems (RPS). The radiation impedance is required to determine the current in the overall tether circuit. In a cold plasma model, radiation occurs mainly in the Alfven and fast magnetosonic modes, exhibiting a large refraction index. The radiation impedance of insulated tethers is determined for both modes and either mission. Unlike the Earth ionospheric case, the low-density, highly magnetized Jovian plasma makes the electron gyrofrequency much larger than the plasma frequency; this substantially modifies the power spectrum for either mode by increasing the Alfven velocity. Finally, an estimation of the radiation impedance of bare tethers is considered. In LJO, a spacecraft orbiting in a slow downward spiral under the radiation belts would allow determining magnetic field structure and atmospheric composition for understanding the formation, evolution, and structure of Jupiter. Additionally, if the cathodic contactor is switched off, a tether floats electrically, allowing e-beam emission that generate auroras. On/off switching produces bias/current pulses and signal emission, which might be used for Jovian plasma diagnostics.
Resumo:
En el artículo se discute el papel de la energía hidroeléctrica en el marco del sistema eléctrico español, donde existe una elevada penetración de energías no gestionables con una tendencia clara a aumentar en los próximos años. El desarrollo de nuevas centrales hidroeléctricas se basará probablemente en centrales reversibles. La energía hidroeléctrica es una tecnología madura y eficiente para el almacenamiento de energía a gran escala y contribuye por tanto de manera decisiva a la integración de fuentes renovables no gestionables. Los beneficios obtenidos con la operación punta-valle pueden ser insuficientes para compensar el coste de una nueva central. Sin embargo, los ingresos obtenidos pueden incrementarse sustancialmente mediante su participación en los servicios de ajuste del sistema. Ello requeriría un diseño apropiado del mercado eléctrico. La contribución de las centrales hidráulicas reversibles al balance producción-consumo puede extenderse a las horas valle utilizando, bien bombeo en velocidad variable o bien una configuración de cortocircuito hidráulico. La necesidad de mitigar los efectos hidrológicos aguas abajo de las centrales hidroeléctricas puede introducir algunas restricciones en la operación que limitaría de algún modo los servicios descritos más arriba. Sin embargo, cabe esperar que los efectos ambientales provocados por las centrales hidráulicas reversibles sean significativamente menores. In this paper the role of hydropower in electric power systems is discussed, in the framework of the Spanish system, where a high penetration of intermittent power sources exists, showing a clear trend to increase in next years. The development of new hydro power facilities will be likely based on pumped storage hydro power plants. Hydropower is a mature and efficient technology for large-scale energy storage and therefore represents a key contribution for the integration of intermittent power sources, such as wind or photovoltaic. The benefits obtained from load shifting may be insufficient to compensate the costs of a new plant. However, the obtained revenues can significantly increase through its contribution to providing ancillary services. This would require an appropriate design of the electricity market. The contribution of pumped storage hydro power plants to balancing services can be extended to off-peak hours, using either variable speed pumping or the hydraulic shortcircuit configuration. The need to mitigate hydrological effects downstream of hydro plants may introduce some operational constraints which could limit to some extent the services described above. However environmental effects caused by pumped storage hydro power plants are expected to be significantly smaller.
Resumo:
As is well known B.E.M. is obtained as a mixture of the integral representation formula of classical elasticity and the discretization philosophy of the finite element method (F.E.M.). The paper presents the application of B.E.M. to elastodynamic problems. Both the transient and steady state solutions are presented as well as some techniques to simplify problems with a free-stress boundary.