63 resultados para Nonlinear Dynamic Response


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The city of Lorca (Spain) was hit on May 11th 2011 by two consecutive earthquakes with 4.6 and 5.2 Mw respectively, causing casualties and important damage in buildings. Lorca is located in the south-east region of Spain and settled on the trace of the Murcia-Totana-Lorca fault. Although the magnitudes of these ground motions were not severe, the damage observed was considerable over a great amount of buildings. More than 300 of them have been demolished and many others are being retrofitted. This paper reports a field study on the damage caused by these earthquakes. The observed damage is related with the structural typology. Further, prototypes of the damaged buildings are idealized with nonlinear numerical models and their seismic behavior and proneness to damage concentration is further investigated through dynamic response analyses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

High switching frequencies (several MHz) allow the integration of low power DC/DC converters. Although, in theory, a high switching frequency would make possible to implement a conventional Voltage Mode control (VMC) or Peak Current Mode control (PCMC) with very high bandwidth, in practice, parasitic effects and robustness limits the applicability of these control techniques. This paper compares VMC and CMC techniques with the V2IC control. This control is based on two loops. The fast internal loop has information of the output capacitor current and the error voltage, providing fast dynamic response under load and voltage reference steps, while the slow external voltage loop provides accurate steady state regulation. This paper shows the fast dynamic response of the V2IC control under load and output voltage reference steps and its robustness operating with additional output capacitors added by the customer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A notorious advantage of wireless transmission is a significant reduction and simplification in wiring and harness. There are a lot of applications of wireless systems, but in many occasions sensor nodes require a specific housing to protect the electronics from hush environmental conditions. Nowadays the information is scarce and nonspecific on the dynamic behaviour of WSN and RFID. Therefore the purpose of this study is to evaluate the dynamic behaviour of the sensors. A series of trials were designed and performed covering temperature steps between cold room (5 °C), room temperature (23 °C) and heated environment (35 °C). As sensor nodes: three Crossbow motes, a surface mounted Nlaza module (with sensor Sensirion located on the motherboard), an aerial mounted Nlaza where the Sensirion sensor stayed at the end of a cable), and four tags RFID Turbo Tag (T700 model with and without housing), and 702-B (with and without housing). To assess the dynamic behaviour a first order response approach is used and fitted with dedicated optimization tools programmed in Matlab that allow extracting the time response (?) and corresponding determination coefficient (r2) with regard to experimental data. The shorter response time (20.9 s) is found for the uncoated T 700 tag which encapsulated version provides a significantly higher response (107.2 s). The highest ? corresponds to the Crossbow modules (144.4 s), followed by the surface mounted Nlaza module (288.1 s), while the module with aerial mounted sensor gives a response certainly close above to the T700 without coating (42.8 s). As a conclusion, the dynamic response of temperature sensors within wireless and RFID nodes is dramatically influenced by the way they are housed (to protect them from the environment) as well as by the heat released by the node electronics itself; its characterization is basic to allow monitoring of high rate temperature changes and to certify the cold chain. Besides the time to rise and to recover is significantly different being mostly higher for the latter than for the former.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Underpasses are common in modern railway lines. Wildlife corridors and drainage conduits often fall into this category of partially buried structures. Their dynamic behaviour has received far less attention than that of other structures such as bridges, but their large number makes their study an interesting challenge in order to achieve safe and cost-effective structures. As ballast operations are a key life cycle cost, and excessive vibrations increase the need of ballast regulation in order to ensure track geometry, special attention is paid to accelerations, the values of which should be limited to avoid track instability according to Eurocode. In this paper, the data obtained during on site measurements on culverts belonging to a Spanish high-speed train line are presented. A set of six rectangular-shaped, closed-frame underpasses were monitored under traffic loading. Acceleration records at different points of the structures are presented and discussed. They reveal a non-uniform dynamic response of the roof-slab, with the highest observed values below the occupied track. Also, they indicate that the dynamic response is important up to frequencies higher than those usually observed for standard simply supported bridges. Finally, they are used to obtain a heuristic rule to estimate acceleration levels on the roof-slab.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Strong motion obtained in instrumental short-span bridges show the importance of the abutments in the dynamic response of the whole structure. Many models have been used in order to take into account the influence of pier foundations although no reliable ones have been used to analyse the abutment performance. In this work three-dimensional Boundary Element models in frequency domain have been proposed and dimensionless dynamic stiffness of standard bridge abutments have been obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, a methodology is proposed to find the dynamic poles of a capacitive pressure transmitter in order to enhance and extend the online surveillance of this type of sensor based on the response time measurement by applying noise analysis techniques and the dynamic data system procedure. Several measurements taken from a pressurized water reactor have been analyzed. The methodology proposes an autoregressive fit whose order is determined by the sensor dynamic poles. Nevertheless, the signals that have been analyzed could not be filtered properly in order to remove the plant noise; thus, this was considered as an additional pair of complex conjugate poles. With this methodology we have come up with the numerical value of the sensor second real pole in spite of its low influence on the sensor dynamic response. This opens up a more accurate online sensor surveillance since the previous methods were achieved by considering one real pole only.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this article, a model for the determination of displacements, strains, and stresses of a submarine pipeline during its construction is presented. Typically, polyethylene outfall pipelines are the ones treated by this model. The process is carried out from an initial floating situation to the final laying position on the seabed. The following control variables are considered in the laying process: the axial load in the pipe, the flooded inner length, and the distance of the control barge from the coast. External loads such as self-weight, dead loads, and forces due to currents and small waves are also taken into account.This paper describes both the conceptual framework for the proposed model and its practical application in a real engineering situation. The authors also consider how the model might be used as a tool to study how sensitive the behavior of the pipeline is to small changes in the values of the control variables. A detailed description of the actions is considered, especially the ones related to the marine environment such as buoyancy, current, and sea waves. The structural behavior of the pipeline is simulated in the framework of a geometrically nonlinear dynamic analysis. The pipeline is assumed to be a two-dimensional Navier_Bernoulli beam. In the nonlinear analysis an updated Lagrangian formulation is used, and special care is taken regarding the numerical aspects of sea bed contact, follower forces due to external water pressures, and dynamic actions. The paper concludes by describing the implementation of the proposed techniques, using the ANSYS computer program with a number of subroutines developed by the authors. This implementation permits simulation of the two-dimensional structural pipe behavior of the whole construction process. A sensitivity analysis of the bending moments, axial forces, and stresses for different values of the control variables is carried out. Using the techniques described, the engineer may optimize the construction steps in the pipe laying process

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El gran desarrollo experimentado por la alta velocidad en los principales países de la Unión Europea, en los últimos 30 años, hace que este campo haya sido y aún sea uno de los principales referentes en lo que a investigación se refiere. Por otra parte, la aparición del concepto super − alta velocidad hace que la investigación en el campo de la ingeniería ferroviaria siga adquiriendo importancia en los principales centros de investigación de los países en los que se desea implantar este modo de transporte, o en los que habiendo sido ya implantado, se pretenda mejorar. Las premisas de eficacia, eficiencia, seguridad y confort, que este medio de transporte tiene como razón de ser pueden verse comprometidas por diversos factores. Las zonas de transición, definidas en la ingeniería ferroviaria como aquellas secciones en las que se produce un cambio en las condiciones de soporte de la vía, pueden afectar al normal comportamiento para el que fue diseñada la infraestructura, comprometiendo seriamente los estándares de eficiencia en el tiempo de viaje, confort de los pasajeros y aumentando considerablemente los costes de mantenimiento de la vía, si no se toman las medidas oportunas. En esta tesis se realiza un estudio detallado de la zonas de transición, concretamente de aquellas en las que existe una cambio en la rigidez vertical de la vía debido a la presencia de un marco hidráulico. Para realizar dicho estudio se lleva a cabo un análisis numérico de interacción entre el vehículo y la estructura, con un modelo bidimensional de elemento finitos, calibrado experimentalmente, en estado de tensión plana. En este análisis se tiene en cuenta el efecto de las irregularidades de la vía y el comportamiento mecánico de la interfaz suelo-estructura, con el objetivo de reproducir de la forma más real posible el efecto de interacción entre el vehículo, la vía y la estructura. Otros efectos como la influencia de la velocidad del tren y los asientos diferenciales, debidos a deformaciones por consolidación de los terraplenes a ambos lados el marco hidráulico, son también analizados en este trabajo. En esta tesis, los cálculos de interacción se han llevado a cabo en dos fases diferentes. En la primera, se ha considerado una interacción sencilla debida al paso de un bogie de un tren Eurostar. Los cálculos derivados de esta fase se han denominado cálculos a corto plazo. En la segunda, se ha realizado un análisis considerando múltiples pasos de bogie del tren Eurostar, conformando un análisis de degradación en el que se tiene en cuenta, en cada ciclo, la deformación de la capa de balasto. Los cálculos derivados de esta fase, son denominados en el texto como cálculos a largo plazo. Los resultados analizados muestran que la utilización de los denominados elementos de contacto es fundamental cuando se desea estudiar la influencia de asientos diferenciales, especialmente en transiciones terraplén-estructura en las que la cuña de cimentación no llega hasta la base de cimentación de la estructura. Por otra parte, tener en cuenta los asientos del terraplén, es sumamente importante, cuando se desea realizar un análisis de degradación de la vía ya que su influencia en la interacción entre el vehículo y la vía es muy elevada, especialmente para valores altos de velocidad del tren. En cuanto a la influencia de las irregularidades de la vía, en los cálculos efectuados, se revela que su importancia es muy notable, siendo su influencia muy destacada cuanto mayor sea la velocidad del tren. En este punto cabe destacar la diferencia de resultados derivada de la consideración de perfiles de irregularidades de distinta naturaleza. Los resultados provenientes de considerar perfiles artificiales son en general muy elevados, siendo estos más apropiados para realizar estudios de otra índole, como por ejemplo de seguridad al descarrilamiento. Los resultados provenientes de perfiles reales, dados por diferentes Administradores ferroviarios, presentan resultados menos elevados y más propios del problema analizar. Su influencia en la interacción dinámica entre el vehículo y la vía es muy importante, especialmente para velocidades elevadas del tren. Además el fenómeno de degradación conocido como danza de traviesas, asociado a zonas de transición, es muy susceptible a la consideración de irregularidades de la vía, tal y como se desprende de los cálculos efectuados a largo plazo. The major development experienced by high speed in the main countries of the European Union, in the last 30 years, makes railway research one of the main references in the research field. It should also be mentioned that the emergence of the concept superhigh − speed makes research in the field of Railway Engineering continues to gain importance in major research centers in the countries in which this mode of transportation is already implemented or planned to be implemented. The characteristics that this transport has as rationale such as: effectiveness, efficiency, safety and comfort, may be compromised by several factors. The transition zones are defined in railway engineering as a region in which there is an abrupt change of track stiffness. This stiffness variation can affect the normal behavior for which the infrastructure has been designed, seriously compromising efficiency standards in the travel time, passenger comfort and significantly increasing the costs of track maintenance, if appropriate measures are not taken. In this thesis a detailed study of the transition zones has been performed, particularly of those in which there is a change in vertical stiffness of the track due to the presence of a reinforced concrete culvert. To perform such a study a numerical interaction analysis between the vehicle, the track and the structure has been developed. With this purpose a two-dimensional finite element model, experimentally calibrated, in a state of plane stress, has been used. The implemented numerical models have considered the effects of track irregularities and mechanical behavior of soil-structure interface, with the objective of reproducing as accurately as possible the dynamic interaction between the vehicle the track and the structure. Other effects such as the influence of train speed and differential settlement, due to secondary consolidation of the embankments on both sides of culvert, have also been analyzed. In this work, the interaction analysis has been carried out in two different phases. In the first part a simple interaction due to the passage of a bogie of a Eurostar train has been considered. Calculations derived from this phase have been named short-term analysis. In the second part, a multi-load assessment considering an Eurostar train bogie moving along the transition zone, has been performed. The objective here is to simulate a degradation process in which vertical deformation of the ballast layer was considered. Calculations derived from this phase have been named long-term analysis. The analyzed results show that the use of so-called contact elements is essential when one wants to analyze the influence of differential settlements, especially in embankment-structure transitions in which the wedge-shaped backfill does not reach the foundation base of the structure. Moreover, considering embankment settlement is extremely important when it is desired to perform an analysis of track degradation. In these cases the influence on the interaction behaviour between the vehicle and the track is very high, especially for higher values of speed train. Regarding the influence of the track irregularities, this study has proven that the track’s dynamic response is heavily influenced by the irregularity profile and that this influence is more important for higher train velocities. It should also be noted that the difference in results derived from consideration of irregularities profiles of different nature. The results coming from artificial profiles are generally very high, these might be more appropriate in order to study other effects, such as derailment safety. Results from real profiles, given by the monitoring works of different rail Managers, are softer and they fit better to the context of this thesis. The influence of irregularity profiles on the dynamic interaction between the train and the track is very important, especially for high-speeds of the train. Furthermore, the degradation phenomenon known as hanging sleepers, associated with transition zones, is very susceptible to the consideration of track irregularities, as it can be concluded from the long-term analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Es conocido que las dimensiones de los puentes de ferrocarril han ido cambiando debido a las estrictas condiciones de trazado impuestas en las líneas de alta velocidad. Además, la creciente preocupación de la sociedad por cuidar y proteger el medio ambiente, reflejado en la correspondiente normativa, ha generado nuevos condicionantes en el diseño de estas infraestructuras. En concreto, se ha limitado el movimiento de grandes volúmenes de terreno particularmente en los espacios protegidos. Por estas razones, hoy en día se proyectan y construyen puentes de ferrocarril más altos y más largos en todo el mundo. En España se han construido varios viaductos de pilas altas para líneas de alta velocidad. Ejemplos de estas infraestructuras son el Viaducto O’Eixo y el Viaducto de Barbantiño, situados en la línea de alta velocidad Madrid-Galicia, Estos viaductos altos se caracterizan por tener una mayor flexibilidad lateral y una frecuencia fundamental de oscilación baja, de hasta 0.2 Hz. La respuesta dinámica de este tipo de estructura puede aumentar como consecuencia de la aproximación entre la frecuencias propias de la misma y las de excitación debidas al paso del tren y a la acción del viento. Por lo tanto, estas estructuras pueden presentar problemas a la hora de cumplir con las limitaciones impuestas en las normas de diseño de puentes de ferrocarril, y otras, para garantizar la seguridad del tráfico y el confort de los viajeros. La respuesta dinámica lateral de viaductos de pilas altas no ha sido suficientemente estudiada en la literatura científica. Se pueden intuir varios de los motivos para explicar esta carencia. El primero es la relativamente reciente aparición de este tipo de viaductos asociados al desarrollo de la alta velocidad. Por otro lado, se hace necesario, para estudiar este tema, construir nuevos modelos numéricos adecuados para el estudio de la interacción dinámica lateral del puente y del tren. La interacción entre el puente y un tren viajando sobre él es un problema dinámico no lineal, dependiente del tiempo y de acoplamiento entre los dos subsistemas que intervienen (vehículo y puente). Los dos subsistemas, que pueden ser modelados como estructuras elásticas, interaccionan el uno con el otro a través de las fuerzas de contacto, que tiene una marcada naturaleza no lineal por el rozamiento entre rueda y carril, y por la geometría de los perfiles de estos dos elementos en contacto. En esta tesis, se desarrolla la formulación completa de un modelo no lineal de interacción tren-vía-puente-viento que reproduce adecuadamente las fuerzas laterales de contacto rueda-carril, fuerzas que van a tener una gran influencia en los índices de seguridad del tráfico. Este modelo se ha validado a partir de casos resueltos en la literatura científica, y de medidas experimentales tomadas en eventos dinámicos ocurridos en los viaductos de Arroyo de Valle y Arroyo de las Piedras. Puentes altos que han estado monitorizados en servicio durante dos años. En los estudios realizados en este trabajo, se cuantifican, empleando el modelo construido, los niveles de seguridad del tráfico y de confort de los pasajeros de trenes ligeros de alta velocidad, como el tren articulado AVE S-100, que viajan sobre viaductos altos sometidos, o no, a fuertes vientos laterales racheados. Finalmente, se ha obtenido el grado de mejora de la seguridad del tráfico y del confort de los viajeros, cuando se emplean pantallas anti-viento en el tablero y amortiguadores de masa sintonizados en la cabeza de las pilas de un viaducto alto. Resultando, el uso simultaneo de estos dos dispositivos (pantallas y amortiguadores de masa), en puentes altos de líneas de alta velocidad, una opción a considerar en la construcción de estas estructuras para elevar significativamente el nivel de servicio de las mismas. It is known that dimensions of railway bridges have been changing due to the strict high-speed lines layout parameters. Moreover, the growing concern of society to take care of and protect the environment, reflected in the corresponding regulations, has created new environment requirements for the design of these infrastructures. Particularly, the mentioned regulations do not allow designers to move far from terrain to build these railway lines. Due to all these reasons, longer and higher railway bridges are being designed and built around the world. In Spain, several high pier railway viaducts have been built for high speed lines. Barbantiño Viaduct and Eixo Viaduct, belonging to the Madrid-Galicia high speed line, are examples of this kind of structures. These high viaducts have great lateral flexibility and a low fundamental vibration frequency of down to 0.2 Hz. The dynamic response of high speed railway bridges may increase because of the approximation between the natural viaduct frequencies and the excitation ones due to the train travel and the wind action. Therefore, this bridge response could not satisfy the serviceability limits states, for traffic safety and for passenger comfort, considered by the design standards of high speed bridges. It is difficult to find papers in the scientific literature about the lateral response of high-speed trains travel over long viaducts with high piers. Several reasons could explain this issue. On one hand, the construction of this kind of viaduct is relatively recent and it is associated to the development of the high speed railway. On the other hand, in order to study the dynamic lateral interaction between the train and the high bridge, it is necessary to build new numerical and complex models. The interaction between the bridge-track subsystem and the vehicle subsystem travelling over the bridge is a coupling, nonlinear and time dependent problem. Both subsystems, train and bridge, which can be modelled as elastic structures, interact each other through the contact forces. These forces have a strong nonlinear nature due to the friction and the geometry of rail and wheel profiles. In this thesis, the full formulation of a train-track-bridge-wind nonlinear interaction model is developed. This model can reproduce properly the lateral contact wheel-rail forces, which have a great influence on traffic safety indices. The validation of the model built has been reached through interaction solved cases found in the scientific literature and experimental measures taken in dynamic events which happened at Arroyo de las Piedras and Arroyo del Valle Viaducts. These high bridges have been controlled during two years of service by means of structural health monitoring. In the studies carried out for this thesis, the levels of traffic safety and passenger comfort are quantified using the interaction model built, in the cases of high speed and light trains, as AVE S-100, travelling over high pier bridges and with or without lateral turbulent winds acting. Finally, the improvement rate of the traffic safety and passenger comfort has been obtained, when wind barriers are used at the bridge deck and tuned mass dampers are installed at the pier heads of a high viaduct. The installation of both devices, wind barriers and tuned mass damper, at the same time, turned out to be a good option to be considered in the design of high pier railway viaducts, to improve significantly the serviceability level of this kind of structures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Esta tesis propone una completa formulación termo-mecánica para la simulación no-lineal de mecanismos flexibles basada en métodos libres de malla. El enfoque se basa en tres pilares principales: la formulación de Lagrangiano total para medios continuos, la discretización de Bubnov-Galerkin, y las funciones de forma libres de malla. Los métodos sin malla se caracterizan por la definición de un conjunto de funciones de forma en dominios solapados, junto con una malla de integración de las ecuaciones discretas de balance. Dos tipos de funciones de forma se han seleccionado como representación de las familias interpolantes (Funciones de Base Radial) y aproximantes (Mínimos Cuadrados Móviles). Su formulación se ha adaptado haciendo sus parámetros compatibles, y su ausencia de conectividad predefinida se ha aprovechado para interconectar múltiples dominios de manera automática, permitiendo el uso de mallas de fondo no conformes. Se propone una formulación generalizada de restricciones, juntas y contactos, válida para sólidos rígidos y flexibles, siendo estos últimos discretizados mediante elementos finitos (MEF) o libres de malla. La mayor ventaja de este enfoque reside en que independiza completamente el dominio con respecto de las uniones y acciones externas a cada sólido, permitiendo su definición incluso fuera del contorno. Al mismo tiempo, también se minimiza el número de ecuaciones de restricción necesarias para la definición de uniones realistas. Las diversas validaciones, ejemplos y comparaciones detalladas muestran como el enfoque propuesto es genérico y extensible a un gran número de sistemas. En concreto, las comparaciones con el MEF indican una importante reducción del error para igual número de nodos, tanto en simulaciones mecánicas, como térmicas y termo-mecánicas acopladas. A igualdad de error, la eficiencia numérica de los métodos libres de malla es mayor que la del MEF cuanto más grosera es la discretización. Finalmente, la formulación se aplica a un problema de diseño real sobre el mantenimiento de estructuras masivas en el interior de un reactor de fusión, demostrando su viabilidad en análisis de problemas reales, y a su vez mostrando su potencial para su uso en simulación en tiempo real de sistemas no-lineales. A new complete formulation is proposed for the simulation of nonlinear dynamic of multibody systems with thermo-mechanical behaviour. The approach is founded in three main pillars: total Lagrangian formulation, Bubnov-Galerkin discretization, and meshfree shape functions. Meshfree methods are characterized by the definition of a set of shape functions in overlapping domains, and a background grid for integration of the Galerkin discrete equations. Two different types of shape functions have been chosen as representatives of interpolation (Radial Basis Functions), and approximation (Moving Least Squares) families. Their formulation has been adapted to use compatible parameters, and their lack of predefined connectivity is used to interconnect different domains seamlessly, allowing the use of non-conforming meshes. A generalized formulation for constraints, joints, and contacts is proposed, which is valid for rigid and flexible solids, being the later discretized using either finite elements (FEM) or meshfree methods. The greatest advantage of this approach is that makes the domain completely independent of the external links and actions, allowing to even define them outside of the boundary. At the same time, the number of constraint equations needed for defining realistic joints is minimized. Validation, examples, and benchmarks are provided for the proposed formulation, demonstrating that the approach is generic and extensible to further problems. Comparisons with FEM show a much lower error for the same number of nodes, both for mechanical and thermal analyses. The numerical efficiency is also better when coarse discretizations are used. A final demonstration to a real problem for handling massive structures inside of a fusion reactor is presented. It demonstrates that the application of meshfree methods is feasible and can provide an advantage towards the definition of nonlinear real-time simulation models.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El objetivo de esta tesis es el estudio de la respuesta estructural de los gasoductos sometidas a solicitaciones estáticas y dinámicas, enfocando prioritariamente en la respuesta sísmica. Los gasoductos, como las tuberías en general, se utilizan principalmente para la transportación de fluidos, como agua, gas o petróleo, de ahí la importancia de que el diseño y la estructura se realicen adecuadamente. La tubería debe ser capaz de soportar tanto los efectos de cargas estáticas como las debidas al peso propio o de la presión de la tierra, así como los diferentes tipos de cargas dinámicas ocurridas durante un evento sísmico, como los debidos a las ondas o el desplazamiento de fallas. En la primera parte de la tesis se describen aspectos generales de la tubería y su uso, y se da una breve historia de uso en la industria y las redes de abastecimiento urbano. Aparte de otros aspectos, se discuten las ventajas y desventajas de los diferentes materiales de las tuberías. En la segunda parte de la tesis se desarrollan las ecuaciones de equilibrio de una sección transversal de la tubería bajo cargas estáticas, tales como la presión interna, peso propio, presión de la tierra y las cargas externas. Un número de diferentes combinaciones de carga es analizado por medio de programas codificados como Matlab, los cuales se han desarrollado específicamente para este propósito. Los resultados se comparan con los obtenidos en Ansys utilizando un código de elementos finitos. En la tercera parte se presenta la respuesta dinámica de las tuberías, que abarca los efectos de las ondas y los desplazamientos de fallas. Se presentan las características relevantes del suelo como las velocidades de ondas, así como los métodos para estimar el desplazamiento máximo de las fallas. Un estudio paramétrico se emplea para ilustrar la influencia de estos parámetros en la respuesta estructural de la tubería. Con este fin se han utilizado dos métodos, el Pseudoestático y el Simplificado. En la última parte de la tesis son desarrollados los modelos de elementos finitos que permiten simular adecuadamente el comportamiento no lineal del suelo y la tubería. Los resultados se comparan con los obtenidos por un método simplificado utilizado con frecuencia que fue propuesto por Kennedy en 1977. Estudios paramétricos se presentan con el fin de examinar la validez de las hipótesis del método de Kennedy. La tesis concluye con recomendaciones que indican en qué casos los resultados obtenidos por el método de Kennedy son conservadores y cuando es preferible utilizar modelos de elementos finitos para estimar la respuesta de las tuberías durante los terremotos. ABSTRACT The subject of this thesis is the study of the structural response of pipelines subjected to static and dynamic loads with special attention to seismic design loads. Pipelines, as pipes in general, are used primarily for the transportation of fluids like water, gas or oil, hence the importance of an adequate design and structural behaviour. The pipe must be able to withstand both the effects of static loads like those due to self-weight or earth pressure as well as the different types of dynamic loads during a seismic event like those due to wave passing or fault displacements. In the first part of the thesis general aspects of pipelines and their use are described and a brief history of their usage in industry and for urban supply networks is given. Apart from other aspects, the advantages and disadvantages of different pipe materials are discussed. In the second part of the thesis the equilibrium equations of a transverse section of the pipe under static loads such as internal pressure, self-weight, earth pressure and external loads are developed. A number of different load combinations is analysed by means of programs coded in Matlab that have been specifically developed for this purpose. The results are compared to those obtained with the commercial Finite Element code Ansys. In the third part the dynamic response of pipelines during earthquakes is presented, covering the effects of passing waves and fault displacements. Relevant soil characteristics like wave propagation velocities as well as methods to estimate the maximum fault displacements are presented. A parametric study is employed to illustrate the influences of these parameters on the structural response of the pipe. To this end two methods have been used, the Pseudostatic and the Simplified method. In the last part of the thesis Finite Element models are developed which allow to adequately simulate the nonlinear behaviour of the soil and the pipe. The results are compared to those obtained by a frequently used simplified method which was proposed by Kennedy in 1977. Parametric studies are presented in order to examine the validity of the hypotheses Kennedys’ method is based on. The thesis concludes with recommendations indicating in which cases the results obtained by Kennedy’s method are conservative and when it is preferable to use Finite Element models to estimate the response of pipelines during earthquakes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Laminatedglass is composed of two glass layers and a thin intermediate PVB layer, strongly influencing PVB's viscoelastic behaviour its dynamic response. While natural frequencies are relatively easily identified even with simplified FE models, damping ratios are not identified with such an ease. In order to determine to what extent external factors influence dampingidentification, different tests have been carried out. The external factors considered, apart from temperature, are accelerometers, connection cables and the effect of the glass layers. To analyse the influence of the accelerometers and their connection cables a laser measuring device was employed considering three possibilities: sample without instrumentation, sample with the accelerometers fixed and sample completely instrumented. When the sample is completely instrumented, accelerometer readings are also analysed. To take into consideration the effect of the glass layers, tests were realised both for laminatedglass and monolithic samples. This paper presents in depth data analysis of the different configurations and establishes criteria for data acquisition when testing laminatedglass.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Laminated glass is a sandwich element consisting of two or more glass sheets, with one or more interlayers of polyvinyl butyral (PVB). The dynamic response of laminated glass beams and plates can be predicted using analytical or numerical models in which the glass and the PVB are usually modelled as linear-elastic and linear viscoelastic materials, respectively. In this work the dynamic behavior of laminated glass beams are predicted using a finite element model and the analytical model of Ross-Kerwin-Ungar. The numerical and analytical results are compared with those obtained by operational modal analysis performed at different temperatures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The operation of a multiphase topology, ideally, without energy storage presents the advantage of achieving very high efficiency over a wide load range as well as a fast dynamic response. However, ideal no-energy storage operation also implies a limitation in the regulation capability of the topology, the output voltage can only take discrete values. These features (high efficiency and discrete regulation capability) of the proposed energy conversion strategy enable the topology as a candidate for `DC-DC transformer' applications. The advantages, drawbacks and the operating principle of this concept, implemented with a `closed chain' magnetic structure have been already presented. In this work, the minimum energy storage operation, is applied to two different magnetic structures. These magnetic structures are called `closed chain' and `pyramidal' the main advantage of the `pyramidal' coupling structure is to improve the size of the converter without increasing the operating frequency. Both magnetic structures are analyzed, compared and experimentally implemented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There are many the requirements that modern power converters should fulfill. Most of the applications where these converters are used, demand smaller converters with high efficiency, improved power density and a fast dynamic response. For instance, loads like microprocessors demand aggressive current steps with very high slew rates (100A/mus and higher); besides, during these load steps, the supply voltage of the microprocessor should be kept within tight limits in order to ensure its correct performance. The accomplishment of these requirements is not an easy task; complex solutions like advanced topologies - such as multiphase converters- as well as advanced control strategies are often needed. Besides, it is also necessary to operate the converter at high switching frequencies and to use capacitors with high capacitance and low ESR. Improving the dynamic response of power converters does not rely only on the control strategy but also the power topology should be suited to enable a fast dynamic response. Moreover, in later years, a fast dynamic response does not only mean accomplishing fast load steps but output voltage steps are gaining importance as well. At least, two applications that require fast voltage changes can be named: Low power microprocessors. In these devices, the voltage supply is changed according to the workload and the operating frequency of the microprocessor is changed at the same time. An important reduction in voltage dependent losses can be achieved with such changes. This technique is known as Dynamic Voltage Scaling (DVS). Another application where important energy savings can be achieved by means of changing the supply voltage are Radio Frequency Power Amplifiers. For example, RF architectures based on ‘Envelope Tracking’ and ‘Envelope Elimination and Restoration’ techniques can take advantage of voltage supply modulation and accomplish important energy savings in the power amplifier. However, in order to achieve these efficiency improvements, a power converter with high efficiency and high enough bandwidth (hundreds of kHz or even tens of MHz) is necessary in order to ensure an adequate supply voltage. The main objective of this Thesis is to improve the dynamic response of DC-DC converters from the point of view of the power topology. And the term dynamic response refers both to the load steps and the voltage steps; it is also interesting to modulate the output voltage of the converter with a specific bandwidth. In order to accomplish this, the question of what is it that limits the dynamic response of power converters should be answered. Analyzing this question leads to the conclusion that the dynamic response is limited by the power topology and specifically, by the filter inductance of the converter which is found in series between the input and the output of the converter. The series inductance is the one that determines the gain of the converter and provides the regulation capability. Although the energy stored in the filter inductance enables the regulation and the capability of filtering the output voltage, it imposes a limitation which is the concern of this Thesis. The series inductance stores energy and prevents the current from changing in a fast way, limiting the slew rate of the current through this inductor. Different solutions are proposed in the literature in order to reduce the limit imposed by the filter inductor. Many publications proposing new topologies and improvements to known topologies can be found in the literature. Also, complex control strategies are proposed with the objective of improving the dynamic response in power converters. In the proposed topologies, the energy stored in the series inductor is reduced; examples of these topologies are Multiphase converters, Buck converter operating at very high frequency or adding a low impedance path in parallel with the series inductance. Control techniques proposed in the literature, focus on adjusting the output voltage as fast as allowed by the power stage; examples of these control techniques are: hysteresis control, V 2 control, and minimum time control. In some of the proposed topologies, a reduction in the value of the series inductance is achieved and with this, the energy stored in this magnetic element is reduced; less stored energy means a faster dynamic response. However, in some cases (as in the high frequency Buck converter), the dynamic response is improved at the cost of worsening the efficiency. In this Thesis, a drastic solution is proposed: to completely eliminate the series inductance of the converter. This is a more radical solution when compared to those proposed in the literature. If the series inductance is eliminated, the regulation capability of the converter is limited which can make it difficult to use the topology in one-converter solutions; however, this topology is suitable for power architectures where the energy conversion is done by more than one converter. When the series inductor is eliminated from the converter, the current slew rate is no longer limited and it can be said that the dynamic response of the converter is independent from the switching frequency. This is the main advantage of eliminating the series inductor. The main objective, is to propose an energy conversion strategy that is done without series inductance. Without series inductance, no energy is stored between the input and the output of the converter and the dynamic response would be instantaneous if all the devices were ideal. If the energy transfer from the input to the output of the converter is done instantaneously when a load step occurs, conceptually it would not be necessary to store energy at the output of the converter (no output capacitor COUT would be needed) and if the input source is ideal, the input capacitor CIN would not be necessary. This last feature (no CIN with ideal VIN) is common to all power converters. However, when the concept is actually implemented, parasitic inductances such as leakage inductance of the transformer and the parasitic inductance of the PCB, cannot be avoided because they are inherent to the implementation of the converter. These parasitic elements do not affect significantly to the proposed concept. In this Thesis, it is proposed to operate the converter without series inductance in order to improve the dynamic response of the converter; however, on the other side, the continuous regulation capability of the converter is lost. It is said continuous because, as it will be explained throughout the Thesis, it is indeed possible to achieve discrete regulation; a converter without filter inductance and without energy stored in the magnetic element, is capable to achieve a limited number of output voltages. The changes between these output voltage levels are achieved in a fast way. The proposed energy conversion strategy is implemented by means of a multiphase converter where the coupling of the phases is done by discrete two-winding transformers instead of coupledinductors since transformers are, ideally, no energy storing elements. This idea is the main contribution of this Thesis. The feasibility of this energy conversion strategy is first analyzed and then verified by simulation and by the implementation of experimental prototypes. Once the strategy is proved valid, different options to implement the magnetic structure are analyzed. Three different discrete transformer arrangements are studied and implemented. A converter based on this energy conversion strategy would be designed with a different approach than the one used to design classic converters since an additional design degree of freedom is available. The switching frequency can be chosen according to the design specifications without penalizing the dynamic response or the efficiency. Low operating frequencies can be chosen in order to favor the efficiency; on the other hand, high operating frequencies (MHz) can be chosen in order to favor the size of the converter. For this reason, a particular design procedure is proposed for the ‘inductorless’ conversion strategy. Finally, applications where the features of the proposed conversion strategy (high efficiency with fast dynamic response) are advantageus, are proposed. For example, in two-stage power architectures where a high efficiency converter is needed as the first stage and there is a second stage that provides the fine regulation. Another example are RF power amplifiers where the voltage is modulated following an envelope reference in order to save power; in this application, a high efficiency converter, capable of achieving fast voltage steps is required. The main contributions of this Thesis are the following: The proposal of a conversion strategy that is done, ideally, without storing energy in the magnetic element. The validation and the implementation of the proposed energy conversion strategy. The study of different magnetic structures based on discrete transformers for the implementation of the proposed energy conversion strategy. To elaborate and validate a design procedure. To identify and validate applications for the proposed energy conversion strategy. It is important to remark that this work is done in collaboration with Intel. The particular features of the proposed conversion strategy enable the possibility of solving the problems related to microprocessor powering in a different way. For example, the high efficiency achieved with the proposed conversion strategy enables it as a good candidate to be used for power conditioning, as a first stage in a two-stage power architecture for powering microprocessors.