111 resultados para Micromachined Beams
Resumo:
An impedance-based midspan debonding identification method for RC beams strengthened with FRP strips is presented in this paper using piezoelectric ceramic (PZT) sensor?actuators. To reach this purpose, firstly, a two-dimensional electromechanical impedance model is proposed to predict the electrical admittance of the PZT transducer bonded to the FRP strips of an RC beam. Considering the impedance is measured in high frequencies, a spectral element model of the bonded-PZT?FRP strengthened beam is developed. This model, in conjunction with experimental measurements of PZT transducers, is used to present an updating methodology to quantitatively detect interfacial debonding of these kinds of structures. To improve the performance and accuracy of the detection algorithm in a challenging problem such as ours, the structural health monitoring approach is solved with an ensemble process based on particle of swarm. An adaptive mesh scheme has also been developed to increase the reliability in locating the area in which debonding initiates. Predictions carried out with experimental results have showed the effectiveness and potential of the proposed method to detect prematurely at its earliest stages a critical failure mode such as that due to midspan debonding of the FRP strip.
Resumo:
Fiber reinforced polymer composites (FRP) have found widespread usage in the repair and strengthening of concrete structures. FRP composites exhibit high strength-to-weight ratio, corrosion resistance, and are convenient to use in repair applications. Externally bonded FRP flexural strengthening of concrete beams is the most extended application of this technique. A common cause of failure in such members is associated with intermediate crack-induced debonding (IC debonding) of the FRP substrate from the concrete in an abrupt manner. Continuous monitoring of the concrete?FRP interface is essential to pre- vent IC debonding. Objective condition assessment and performance evaluation are challenging activities since they require some type of monitoring to track the response over a period of time. In this paper, a multi-objective model updating method integrated in the context of structural health monitoring is demonstrated as promising technology for the safety and reliability of this kind of strengthening technique. The proposed method, solved by a multi-objective extension of the particle swarm optimization method, is based on strain measurements under controlled loading. The use of permanently installed fiber Bragg grating (FBG) sensors embedded into the FRP-concrete interface or bonded onto the FRP strip together with the proposed methodology results in an automated method able to operate in an unsupervised mode.
Resumo:
There are significant levels of concern about the relevance and the difficulty of learning some issues on Strength of Materials and Structural Analysis. Most students of Continuum Mechanics and Structural Analysis in Civil Engineering usually point out some key learning aspects as especially difficult for acquiring specific skills. These key concepts entail comprehension difficulties but ease access and applicability to structural analysis in more advanced subjects. Likewise, some elusive but basic structural concepts, such as flexibility, stiffness or influence lines, are paramount for developing further skills required for advanced structural design: tall buildings, arch-type structures as well as bridges. As new curricular itineraries are currently being implemented, it appears appropriate to devise a repository of interactive web-based applications for training in those basic concepts. That will hopefully train the student to understand the complexity of such concepts, to develop intuitive knowledge on actual structural response and to improve their preparation for exams. In this work, a web-based learning assistant system for influence lines on continuous beams is presented. It consists of a collection of interactive user-friendly applications accessible via Web. It is performed in both Spanish and English languages. Rather than a “black box” system, the procedure involves open interaction with the student, who can simulate and virtually envisage the structural response. Thus, the student is enabled to set the geometric, topologic and mechanic layout of a continuous beam and to change or shift the loading and the support conditions. Simultaneously, the changes in the beam response prompt on the screen, so that the effects of the several issues involved in structural analysis become apparent. The system is performed through a set of web pages which encompasses interactive exercises and problems, written in JavaScript under JQuery and DyGraphs frameworks, given that their efficiency and graphic capabilities are renowned. Students can freely boost their self-study on this subject in order to face their exams more confidently. Besides, this collection is expected to be added to the "Virtual Lab of Continuum Mechanics" of the UPM, launched in 2013 (http://serviciosgate.upm.es/laboratoriosvirtuales/laboratorios/medios-continuos-en-construcci%C3%B3n)
Resumo:
It is common to find structures that need to be reinforced due to deterioration or because the function of the building changes. The economic cost involved in these forms of interventions is considerable. Therefore, it is interesting to progress in the existing strengthening techniques and the study of new reinforcement systems. This paper analyses the behaviour of timber beams reinforced with carbon and basalt fiber composite materials. The main objective of this study is to test the stiffness increase produced by the carbon and basalt FRP on reinforced beams. The results show the stiffness increase produced by the different types of reinforcement.
Resumo:
Silicon micromachined waveguide components operating in the WM-250 (WR-1) waveguide band (0.75 to 1.1 THz) are measured. Through lines are used to characterize the waveguide loss with and without an oxide etch to reduce the surface roughness. A sidewall roughness of 100nm is achieved, enabling a waveguide loss of 0.2dB/mm. A 1THz band-pass filter is also measured to characterize the precision of fabrication process. A 1.8% shift in frequency is observed and can be accounted for by the 0.5deg etch angle and 2um expansion of the features by the oxide etch. The measured filter has a 13% 3dB bandwidth and 2.5dB insertion loss through the passband.
Resumo:
Advanced composite materials are increasingly used in the strengthening of reinforced concrete (RC) structures. The use of externally bonded strips made of fibre-reinforced plastics (FRP) as strengthening method has gained widespread acceptance in recent years since it has many advantages over the traditional techniques. However, unfortunately, this strengthening method is often associated with a brittle and sudden failure caused by some form of FRP bond failure, originated at the termination of the FRP material or at intermediate areas in the vicinity of flexural cracks in the RC beam. Up to date, little effort in the early prediction of the debonding in its initial instants even though this effect is not noticeable by simple visual observation. An early detection of this phenomenon might help in taking actions to prevent future catastrophes. Fibre-optic Bragg grating (FBG) sensors are able to measure strains locally with high resolution and accuracy. Furthermore, as their physical size is extremely small compared with other strain measuring components, it enables to be embedded at the concrete-FRP interface for determining the strain distribution without influencing the mechanical properties of the host materials. This paper shows the development of a debonding identification methodology based on strains experimentally measured. For, it a simplified model is implemented to simulate the behaviour of FRP-strengthened reinforced concrete beams. This model is taken as a basis to. develop an model updating procedure able to detect minor debonding at the concrete-FRP interface from experimental strains obtained by using FBG sensors embedded at the interface
A simplified spectral approachfor impedance-based damage identification of frp-strengthened rc beams
Resumo:
Hoy en día, el refuerzo y reparación de estructuras de hormigón armado mediante el pegado de bandas de polímeros reforzados con fibras (FRP) se emplea cada vez con más frecuencia a causa de sus numerosas ventajas. Sin embargo, las vigas reforzadas con esta técnica pueden experimentar un modo de fallo frágil a causa del despegue repentino de la banda de FRP a partir de una fisura intermedia. A pesar de su importancia, el número de trabajos que abordan el estudio de este mecanismo de fallo y su monitorización es muy limitado. Por ello, el desarrollo de metodologías capaces de monitorizar a largo plazo la adherencia de este refuerzo a las estructuras de hormigón e identificar cuándo se inicia el despegue de la banda constituyen un importante desafío a abordar. El principal objetivo de esta tesis es la implementación de una metodología fiable y efectiva, capaz de detectar el despegue de una banda de FRP en una viga de hormigón armado a partir de una fisura intermedia. Para alcanzar este objetivo se ha implementado un procedimiento de calibración numérica a partir de ensayos experimentales. Para ello, en primer lugar, se ha desarrollado un modelo numérico unidimensional simple y no costoso representativo del comportamiento de este tipo vigas de hormigón reforzadas con FRP, basado en un modelo de fisura discreta para el hormigón y el método de elementos espectrales. La formación progresiva de fisuras a flexion y el consiguiente despegue en la interface entre el hormigón y el FRP se formulan mediante la introducción de un nuevo elemento capaz de representar ambos fenómenos simultáneamente sin afectar al procedimiento numérico. Además, con el modelo propuesto, se puede obtener de una forma sencilla la respuesta dinámica en altas frecuencias de este tipo de estructuras, lo cual puede hacer muy útil su uso como herramienta de diagnosis y detección del despegue en su fase inicial mediante una monitorización de la variación de las características dinámicas locales de la estructura. Un método de evaluación no destructivo muy prometedor para la monitorización local de las estructuras es el método de la impedancia usando sensores-actuadores piezoeléctricos (PZT). La impedancia eléctrica de los sensores PZT se puede relacionar con la impedancia mecánica de las estructuras donde se encuentran adheridos Ya que la impedancia mecánica de una estructura se verá afectada por su deterioro, se pueden implementar indicadores de daño mediante una comparación del espectro de admitancia (inversa de la impedancia) a lo largo de distintas etapas durante el periodo de servicio de una estructura. Cualquier cambio en el espectro se podría interpretar como una variación en la integridad de la estructura. La impedancia eléctrica se mide a altas frecuencias con lo cual esta metodología debería ser muy sensible a la detección de estados de daño incipiente local, tal como se desea en la aplicación de este trabajo. Se ha implementado un elemento espectral PZT-FRP como extensión del modelo previamente desarrollado, con el objetivo de poder calcular numéricamente la impedancia eléctrica de sensores PZT adheridos a bandas de FRP sobre una viga de hormigón armado. El modelo, combinado con medidas experimentales captadas mediante sensores PZT, se implementa en el marco de una metodología de calibración de modelos para detectar cuantitativamente el despegue en la interfase entre una banda de FRP y una viga de hormigón. El procedimiento de optimización se resuelve empleando el método del enjambre cooperativo con un algoritmo bagging. Los resultados muestran una gran aproximación en la estimación del daño para el problema propuesto. Adicionalmente, se ha desarrollado también un método adaptativo para el mallado de elementos espectrales con el objetivo de localizar las zonas dañadas a partir de los resultados experimentales, el cual contribuye a aumentar la robustez y efectividad del método propuesto a la hora de identificar daños incipientes en su aparición inicial. Finalmente, se ha llevado a cabo un procedimiento de optimización multi-objetivo para detectar el despegue inicial en una viga de hormigón a escala real reforzada con FRP a partir de las impedancias captadas con una red de sensores PZT instrumentada a lo largo de la longitud de la viga. Cada sensor aporta los datos para definir cada una de las funciones objetivo que definen el procedimiento. Combinando el modelo previo de elementos espectrales con un algoritmo PSO multi-objetivo el procedimiento de detección de daño resultante proporciona resultados satisfactorios considerando la escala de la estructura y todas las incertidumbres características ligadas a este proceso. Los resultados obtenidos prueban la viabilidad y capacidad de los métodos antes mencionados y también su potencial en aplicaciones reales. Abstract Nowadays, the external bonding of fibre reinforced polymer (FRP) plates or sheets is increasingly used for the strengthening and retrofitting of reinforced concrete (RC) structures due to its numerous advantages. However, this kind of strengthening often leads to brittle failure modes being the most dominant failure mode the debonding induced by an intermediate crack (IC). In spite of its importance, the number of studies regarding the IC debonding mechanism and bond health monitoring is very limited. Methodologies able to monitor the long-term efficiency of bonding and successfully identify the initiation of FRP debonding constitute a challenge to be met. The main purpose of this thesisis the implementation of a reliable and effective methodology of damage identification able to detect intermediate crack debonding in FRP-strengthened RC beams. To achieve this goal, a model updating procedure based on numerical simulations and experimental tests has been implemented. For it, firstly, a simple and non-expensive one-dimensional model based on the discrete crack approach for concrete and the spectral element method has been developed. The progressive formation of flexural cracks and subsequent concrete-FRP interfacial debonding is formulated by the introduction of a new element able to represent both phenomena simultaneously without perturbing the numerical procedure. Furthermore, with the proposed model, high frequency dynamic response for these kinds of structures can also be obtained in a very simple and non-expensive way, which makes this procedure very useful as a tool for diagnoses and detection of debonding in its initial stage by monitoring the change in local dynamic characteristics. One very promising active non-destructive evaluation method for local monitoring is impedance-based structural health monitoring(SHM)using piezoelectric ceramic (PZT) sensor-actuators. The electrical impedance of the PZT can be directly related to the mechanical impedance of the host structural component where the PZT transducers are attached. Since the structural mechanical impedance will be affected by the presence of structural damage, comparisons of admittance (inverse of impedance) spectra at various times during the service period of the structure can be used as damage indicator. Any change in the spectra might be an indication of a change in the structural integrity. The electrical impedance is measured at high frequencies with which this methodology appears to be very sensitive to incipient damage in structural systems as desired for our application. Abonded-PZT-FRP spectral beam element approach based on an extension of the previous discrete crack approach is implemented in the calculation of the electrical impedance of the PZT transducer bonded to the FRP plates of a RC beam. This approach in conjunction with the experimental measurements of PZT actuator-sensors mounted on the structure is used to present an updating methodology to quantitatively detect interfacial debonding between a FRP strip and the host RC structure. The updating procedure is solved by using an ensemble particle swarm optimization approach with abagging algorithm, and the results demonstrate a big improvement for the performance and accuracy of the damage detection in the proposed problem. Additionally, an adaptive strategy of spectral element mesh has been also developed to detect damage location with experimental results, which shows the robustness and effectiveness of the proposed method to identify initial and incipient damages at its early stage. Lastly, multi-objective optimization has been carried out to detect debonding damage in a real scale FRP-strengthened RC beam by using impedance signatures. A net of PZT sensors is distributed along the beam to construct impedance-based multiple objectives under gradually induced damage scenario. By combining the spectral element model presented previously and an ensemble multi-objective PSO algorithm, the implemented damage detection process yields satisfactory predictions considering the scale and uncertainties of the structure. The obtained results prove the feasibility and capability of the aforementioned methods and also their potentials in real engineering applications.
Resumo:
Esta Tesis tiene como objetivo principal el desarrollo de métodos de identificación del daño que sean robustos y fiables, enfocados a sistemas estructurales experimentales, fundamentalmente a las estructuras de hormigón armado reforzadas externamente con bandas fibras de polímeros reforzados (FRP). El modo de fallo de este tipo de sistema estructural es crítico, pues generalmente es debido a un despegue repentino y frágil de la banda del refuerzo FRP originado en grietas intermedias causadas por la flexión. La detección de este despegue en su fase inicial es fundamental para prevenir fallos futuros, que pueden ser catastróficos. Inicialmente, se lleva a cabo una revisión del método de la Impedancia Electro-Mecánica (EMI), de cara a exponer sus capacidades para la detección de daño. Una vez la tecnología apropiada es seleccionada, lo que incluye un analizador de impedancias así como novedosos sensores PZT para monitorización inteligente, se ha diseñado un procedimiento automático basado en los registros de impedancias de distintas estructuras de laboratorio. Basándonos en el hecho de que las mediciones de impedancias son posibles gracias a una colocación adecuada de una red de sensores PZT, la estimación de la presencia de daño se realiza analizando los resultados de distintos indicadores de daño obtenidos de la literatura. Para que este proceso sea automático y que no sean necesarios conocimientos previos sobre el método EMI para realizar un experimento, se ha diseñado e implementado un Interfaz Gráfico de Usuario, transformando la medición de impedancias en un proceso fácil e intuitivo. Se evalúa entonces el daño a través de los correspondientes índices de daño, intentando estimar no sólo su severidad, sino también su localización aproximada. El desarrollo de estos experimentos en cualquier estructura genera grandes cantidades de datos que han de ser procesados, y algunas veces los índices de daño no son suficientes para una evaluación completa de la integridad de una estructura. En la mayoría de los casos se pueden encontrar patrones de daño en los datos, pero no se tiene información a priori del estado de la estructura. En este punto, se ha hecho una importante investigación en técnicas de reconocimiento de patrones particularmente en aprendizaje no supervisado, encontrando aplicaciones interesantes en el campo de la medicina. De ahí surge una idea creativa e innovadora: detectar y seguir la evolución del daño en distintas estructuras como si se tratase de un cáncer propagándose por el cuerpo humano. En ese sentido, las lecturas de impedancias se emplean como información intrínseca de la salud de la propia estructura, de forma que se pueden aplicar las mismas técnicas que las empleadas en la investigación del cáncer. En este caso, se ha aplicado un algoritmo de clasificación jerárquica dado que ilustra además la clasificación de los datos de forma gráfica, incluyendo información cualitativa y cuantitativa sobre el daño. Se ha investigado la efectividad de este procedimiento a través de tres estructuras de laboratorio, como son una viga de aluminio, una unión atornillada de aluminio y un bloque de hormigón reforzado con FRP. La primera ayuda a mostrar la efectividad del método en sencillos escenarios de daño simple y múltiple, de forma que las conclusiones extraídas se aplican sobre los otros dos, diseñados para simular condiciones de despegue en distintas estructuras. Demostrada la efectividad del método de clasificación jerárquica de lecturas de impedancias, se aplica el procedimiento sobre las estructuras de hormigón armado reforzadas con bandas de FRP objeto de esta tesis, detectando y clasificando cada estado de daño. Finalmente, y como alternativa al anterior procedimiento, se propone un método para la monitorización continua de la interfase FRP-Hormigón, a través de una red de sensores FBG permanentemente instalados en dicha interfase. De esta forma, se obtienen medidas de deformación de la interfase en condiciones de carga continua, para ser implementadas en un modelo de optimización multiobjetivo, cuya solución se haya por medio de una expansión multiobjetivo del método Particle Swarm Optimization (PSO). La fiabilidad de este último método de detección se investiga a través de sendos ejemplos tanto numéricos como experimentales. ABSTRACT This thesis aims to develop robust and reliable damage identification methods focused on experimental structural systems, in particular Reinforced Concrete (RC) structures externally strengthened with Fiber Reinforced Polymers (FRP) strips. The failure mode of this type of structural system is critical, since it is usually due to sudden and brittle debonding of the FRP reinforcement originating from intermediate flexural cracks. Detection of the debonding in its initial stage is essential thus to prevent future failure, which might be catastrophic. Initially, a revision of the Electro-Mechanical Impedance (EMI) method is carried out, in order to expose its capabilities for local damage detection. Once the appropriate technology is selected, which includes impedance analyzer as well as novel PZT sensors for smart monitoring, an automated procedure has been design based on the impedance signatures of several lab-scale structures. On the basis that capturing impedance measurements is possible thanks to an adequately deployed PZT sensor network, the estimation of damage presence is done by analyzing the results of different damage indices obtained from the literature. In order to make this process automatic so that it is not necessary a priori knowledge of the EMI method to carry out an experimental test, a Graphical User Interface has been designed, turning the impedance measurements into an easy and intuitive procedure. Damage is then assessed through the analysis of the corresponding damage indices, trying to estimate not only the damage severity, but also its approximate location. The development of these tests on any kind of structure generates large amounts of data to be processed, and sometimes the information provided by damage indices is not enough to achieve a complete analysis of the structural health condition. In most of the cases, some damage patterns can be found in the data, but none a priori knowledge of the health condition is given for any structure. At this point, an important research on pattern recognition techniques has been carried out, particularly on unsupervised learning techniques, finding interesting applications in the medicine field. From this investigation, a creative and innovative idea arose: to detect and track the evolution of damage in different structures, as if it were a cancer propagating through a human body. In that sense, the impedance signatures are used to give intrinsic information of the health condition of the structure, so that the same clustering algorithms applied in the cancer research can be applied to the problem addressed in this dissertation. Hierarchical clustering is then applied since it also provides a graphical display of the clustered data, including quantitative and qualitative information about damage. The performance of this approach is firstly investigated using three lab-scale structures, such as a simple aluminium beam, a bolt-jointed aluminium beam and an FRP-strengthened concrete specimen. The first one shows the performance of the method on simple single and multiple damage scenarios, so that the first conclusions can be extracted and applied to the other two experimental tests, which are designed to simulate a debonding condition on different structures. Once the performance of the impedance-based hierarchical clustering method is proven to be successful, it is then applied to the structural system studied in this dissertation, the RC structures externally strengthened with FRP strips, where the debonding failure in the interface between the FRP and the concrete is successfully detected and classified, proving thus the feasibility of this method. Finally, as an alternative to the previous approach, a continuous monitoring procedure of the FRP-Concrete interface is proposed, based on an FBGsensors Network permanently deployed within that interface. In this way, strain measurements can be obtained under controlled loading conditions, and then they are used in order to implement a multi-objective model updating method solved by a multi-objective expansion of the Particle Swarm Optimization (PSO) method. The feasibility of this last proposal is investigated and successfully proven on both numerical and experimental RC beams strengthened with FRP.
Resumo:
A special Working Group, to study and develop standars related to Building Restoration, Rehabilitation and Maintenance, was formed in January 2001 in AENOR (Spanish Association for Codes and Standars) under the management of the Department of Building Construction of the School of Architecture of Madrid (DCTA-UPM). Three groups were organized to deal with different topics: Diagnosis, Techiques and Materials, and Maintenance. In this paper the differents topics in which the Diagnosis Subgroup is working are described: historical studies, constructive description of the building and building pathology. These will be basic to carry out a correct diagnosis of any type of building, whether it is historic or not. In the development of such topics, the recognizable architectural values are justified as they are prior to the diagnosis stage. As an example of the subgroup work, several pathology cards are shown which include: longitudinal cracks of mechanical origin in beams of concrete structures, façade closings and claddings, and general symptoms of installation services.
Resumo:
This thesis contributes to the analysis and design of printed reflectarray antennas. The main part of the work is focused on the analysis of dual offset antennas comprising two reflectarray surfaces, one of them acts as sub-reflector and the second one acts as mainreflector. These configurations introduce additional complexity in several aspects respect to conventional dual offset reflectors, however they present a lot of degrees of freedom that can be used to improve the electrical performance of the antenna. The thesis is organized in four parts: the development of an analysis technique for dualreflectarray antennas, a preliminary validation of such methodology using equivalent reflector systems as reference antennas, a more rigorous validation of the software tool by manufacturing and testing a dual-reflectarray antenna demonstrator and the practical design of dual-reflectarray systems for some applications that show the potential of these kind of configurations to scan the beam and to generate contoured beams. In the first part, a general tool has been implemented to analyze high gain antennas which are constructed of two flat reflectarray structures. The classic reflectarray analysis based on MoM under local periodicity assumption is used for both sub and main reflectarrays, taking into account the incident angle on each reflectarray element. The incident field on the main reflectarray is computed taking into account the field radiated by all the elements on the sub-reflectarray.. Two approaches have been developed, one which employs a simple approximation to reduce the computer run time, and the other which does not, but offers in many cases, improved accuracy. The approximation is based on computing the reflected field on each element on the main reflectarray only once for all the fields radiated by the sub-reflectarray elements, assuming that the response will be the same because the only difference is a small variation on the angle of incidence. This approximation is very accurate when the reflectarray elements on the main reflectarray show a relatively small sensitivity to the angle of incidence. An extension of the analysis technique has been implemented to study dual-reflectarray antennas comprising a main reflectarray printed on a parabolic surface, or in general in a curved surface. In many applications of dual-reflectarray configurations, the reflectarray elements are in the near field of the feed-horn. To consider the near field radiated by the horn, the incident field on each reflectarray element is computed using a spherical mode expansion. In this region, the angles of incidence are moderately wide, and they are considered in the analysis of the reflectarray to better calculate the actual incident field on the sub-reflectarray elements. This technique increases the accuracy for the prediction of co- and cross-polar patterns and antenna gain respect to the case of using ideal feed models. In the second part, as a preliminary validation, the proposed analysis method has been used to design a dual-reflectarray antenna that emulates previous dual-reflector antennas in Ku and W-bands including a reflectarray as subreflector. The results for the dualreflectarray antenna compare very well with those of the parabolic reflector and reflectarray subreflector; radiation patterns, antenna gain and efficiency are practically the same when the main parabolic reflector is substituted by a flat reflectarray. The results show that the gain is only reduced by a few tenths of a dB as a result of the ohmic losses in the reflectarray. The phase adjustment on two surfaces provided by the dual-reflectarray configuration can be used to improve the antenna performance in some applications requiring multiple beams, beam scanning or shaped beams. Third, a very challenging dual-reflectarray antenna demonstrator has been designed, manufactured and tested for a more rigorous validation of the analysis technique presented. The proposed antenna configuration has the feed, the sub-reflectarray and the main-reflectarray in the near field one to each other, so that the conventional far field approximations are not suitable for the analysis of such antenna. This geometry is used as benchmarking for the proposed analysis tool in very stringent conditions. Some aspects of the proposed analysis technique that allow improving the accuracy of the analysis are also discussed. These improvements include a novel method to reduce the inherent cross polarization which is introduced mainly from grounded patch arrays. It has been checked that cross polarization in offset reflectarrays can be significantly reduced by properly adjusting the patch dimensions in the reflectarray in order to produce an overall cancellation of the cross-polarization. The dimensions of the patches are adjusted in order not only to provide the required phase-distribution to shape the beam, but also to exploit the crosses by zero of the cross-polarization components. The last part of the thesis deals with direct applications of the technique described. The technique presented is directly applicable to the design of contoured beam antennas for DBS applications, where the requirements of cross-polarisation are very stringent. The beam shaping is achieved by synthesithing the phase distribution on the main reflectarray while the sub-reflectarray emulates an equivalent hyperbolic subreflector. Dual-reflectarray antennas present also the ability to scan the beam over small angles about boresight. Two possible architectures for a Ku-band antenna are also described based on a dual planar reflectarray configuration that provides electronic beam scanning in a limited angular range. In the first architecture, the beam scanning is achieved by introducing a phase-control in the elements of the sub-reflectarray and the mainreflectarray is passive. A second alternative is also studied, in which the beam scanning is produced using 1-bit control on the main reflectarray, while a passive subreflectarray is designed to provide a large focal distance within a compact configuration. The system aims to develop a solution for bi-directional satellite links for emergency communications. In both proposed architectures, the objective is to provide a compact optics and simplicity to be folded and deployed.
Resumo:
The electromechanical response of piezoelectrically-actuated AlN micromachined bridge resonators has been characterized using laser interferometry and electrical admittance measurements. We compare the response of microbridges with different dimensions and buckling (induced by the initial residual stress of the layers). The resonance frequencies are in good agreement with numerical simulations of the electromechanical behavior of the structures. We show that it is possible to perform a rough tuning of the resonance frequencies by allowing a determined amount of builtin stress in the microbridge during its fabrication. Once the resonator is made, a DC bias added to the AC excitation signal allows to fine-tune the frequency. Our microbridges yield a tuning factor of around 88 Hz/V for a 500 ?m-long microbridge.
Resumo:
El presente trabajo se refiere al estudio teórico-experimental del comportamiento de pilares y vigas de hormigón armado reforzados con fibra de carbono o CFRP. El análisis se realiza considerando que los pilares se refuerzan mediante la técnica de adhesión de tejidos de fibra de carbono, generando un efecto de confinamiento. Las vigas se refuerzan mediante la incorporación de barras del mismo material, con refuerzos a cortante. El objetivo es poder comparar el estudio analítico de este tipo de refuerzos con resultados experimentales obtenidos con anterioridad a la realización de este documento, y así poder obtener conclusiones de las posibles diferencias. Hay que señalar que los modelos experimentales no forman parte de este estudio. Los ensayos en pilares fueron realizados en sección cuadrada y circular evaluando la rotura a compresión de las piezas, habiendo sido éstas escaladas con un factor de reducción de 2,3. Los ensayos correspondientes a vigas se realizaron en sección rectangular, centrándose en la evaluación de la rotura a flexión y habiendo sido escaladas igualmente, pero con un factor de reducción de 1:2. El documento se estructura en cuatro capítulos, cuyo contenido se expone de forma concisa a continuación. En el capítulo uno o marco teórico se exponen los principios de comportamiento y tipologías de los pilares y vigas de hormigón armado, las bases teóricas de su refuerzo y confinamiento, así como las diversas técnicas de refuerzo existentes. Se detalla la técnica con FRP, comparando y analizando sus ventajas e inconvenientes. En el capítulo dos se expone el proceso de fabricación, refuerzo y resultados de los modelos experimentales realizados para ambos elementos estructurales. La obtención de los modelos teóricos forma parte del capítulo tres, comparándose con los resultados experimentales en el cuarto capítulo. Finalmente, en el último capítulo se presentan las conclusiones obtenidas al realizar esta comparativa en el refuerzo de vigas y pilares con fibra de carbono. This work refers to the theoretical and experimental study of the behavior of CFRP reinforced concrete columns and beams. The analysis was done considering that the pillars are reinforced by CFRP wrapping technique, resulting in a confinement effect. The beams are reinforced by the addition of bars of the same material, with shear reinforcements. The objective is to compare the analytical study of this type of reinforcement with experimental results obtained prior to the performance of this document, and draw conclusions for any differences. Notice that experimental models are not part of this study. The tests were performed on circular and square section pillars, evaluating compression fracture of the pieces, having been scaled down with a factor of 2.3. The tests were performed on rectangular section beams, focusing on evaluation of the bending fracture and being scaled down equally, but with a factor of 1:2. The document is divided into four chapters, whose content is set out concisely below. The chapter one or theoretical framework sets out the principles of behavior and types of columns and beams of reinforced concrete, the theoretical basis of its reinforcement and confinement, as well as various existing reinforcement techniques. CFRP technique it’s detailed, comparing and analyzing their advantages and disadvantages. Chapter two describes the process of manufacture, reinforcement and results of experimental models made for both structural elements. Chapter three shows the obtaining of the theoretical models, comparing them with the experimental results in the fourth chapter. Finally, the last chapter presents the conclusions to make this comparison in the strengthening of beams and columns with carbon fiber.
Resumo:
Los polímeros armados con fibras (FRP) se utilizan en refuerzos de estructuras de hormigón debido sobre todo a sus excelentes propiedades mecánicas, su resistencia a la corrosión y a su ligereza que se traduce en facilidad y ahorro en el transporte, puesta en obra y aplicación, la cual se realiza de forma muy rápida, con pocos operarios y utilizando medios auxiliares ligeros, minimizándose las interrupciones del uso de la estructura y las molestias a los usuarios. Las razones presentadas anteriormente, han despertado un gran inter´es por parte de diferentes grupos de investigación a nivel mundial y que actualmente se encuentran desarrollando nuevas técnicas de aplicación y métodos de cálculo. Sin embargo, las investigaciones realizadas hasta la fecha, muestran un procedimiento bien definido y aceptado en lo referente al cálculo a flexión, lo cual no ocurre con el refuerzo a cortante y aunque se ha demostrado que el refuerzo con FRP es un sistema eficaz para incrementar la capacidad ´ultima frente a esfuerzos cortantes, también se pone de manifiesto la necesidad de más estudios experimentales y teóricos para avanzar en el entendimiento de los mecanismos involucrados para este tipo de refuerzo y establecer un procedimiento de diseño apropiado que maximice las excelentes propiedades de este material. Los modelos que explican el comportamiento del refuerzo a cortante de elementos de hormigón armado son complejos y sin transposición directa a fórmulas ingenieriles. Las normas actualmente en vigor, generalmente, establecen empíricamente la capacidad cortante como la suma de las capacidades del hormigón y el refuerzo transversal de acero. Cuando un elemento es reforzado externamente con FRP, los modelos son evidentemente aun más complejos. Las guías y recomendaciones existentes proponen calcular la capacidad del elemento añadiendo la resistencia aportada por el refuerzo externo de FRP a la ya dada por el hormigón y acero transversal. Sin embargo, la idoneidad de este acercamiento es cuestionable puesto que no tiene en cuenta una posible interacción entre refuerzos. Con base en lo anterior se da origen al tema objeto de este trabajo, el cual está orientado al estudio a cortante de elementos de hormigón armado (HA), reforzados externamente con material compuesto de tejido unidireccional de fibra de carbono y resina epoxi. Inicialmente se hace una completa revisión del estado actual del conocimiento de la resistencia a cortante en elementos de hormigón armado con y sin refuerzo externo de FRP, prestando especial atención en los mecanismos actuantes estudiados hasta la fecha. La bibliografía consultada ha sido exhaustiva y actualizada lo que ha permitido el estudio de los modelos propuestos más importantes, tanto para la descripción del fenómeno de adherencia entre hormigón-FRP como de la valoración del aporte al cortante total hecho por el FRP, a través de sendas bases de datos de ensayos de pull-out y de vigas de hormigón armado ensayadas a cortante. Con base en todo lo anterior, se expusieron los mecanismos actuantes en el aporte a cortante hecho por el FRP en elementos de hormigón armado y la forma como las principales guías de cálculo existentes hasta la fecha los abordan. De igual forma se define un modelo de resistencia de esfuerzos para el FRP y se proponen dos modelos para el cálculo de las tensiones o deformaciones efectivas, de los cuales uno esta basado en el modelo de adherencia propuesto por Oller (2005) y el otro en una regresión multivariante para los mecanismos expuestos. Como complemento del estudio de los trabajos encontrados en la literatura, se lleva acabo un programa experimental que, además de aportar más registros a la exigua base de datos existentes, aporte mayor luz a los puntos que se consideran están deficientemente resueltos. Dentro de este programa se realizaron 32 ensayos sobre 16 vigas de 4.5 m de longitud (dos ensayos por viga), reforzadas a cortante con tejido unidireccional de CFRP. Finalmente, estos estudios han permitido proponer modificaciones a las formulaciones existentes en los códigos y guías en vigor. Abstract Its excellent mechanical properties, as well as its corrosion resistance and light weight, which make it easy to apply and inexpensive to ship to the worksite, are the basis of the extended use of fiber reinforced polymer (FRP) as external strengthening for structures. FRP strengthening is a rapid operation calling for only limited labor and lightweight ancillary equipment, all of which minimizes both the interruption of facility usage and user inconvenience. These advantages have aroused considerable interest in civil engineering science and technology and have led to countless applications the world over. Research studies on the shear strength of FRP-strengthened members have been much fewer in number and more controversial than the research on flexural strengthening, for which a more or less standardized and generally accepted procedure has been established. The research conducted and a host of applications around the world have shown that FRP strengthening is an effective technique for raising ultimate shear strength, but it has also revealed a need for further experimental and theoretical research to advance in the understanding of the mechanisms involved and establish suitable design procedures that optimize the excellent properties of this material The models that explain reinforced concrete (RC) shear strength behavior are complex and cannot be directly transposed to engineering formulas. The standards presently in place generally establish shear capacity empirically as the sum of the capacities of the concrete and the passive reinforcement. When members are externally strengthened with FRP, the models are obviously even more complex. The existing guides and recommendations propose calculating capacity by adding the external strength provided by the FRP to the contributions of the concrete and passive reinforcement. The suitability of this approach is questionable, however, because it fails to consider the interaction between passive reinforcement and external strengthening. The subject of this work is based in above, which is focused on externally shear strengthening for reinforced concrete members with unidirectional carbon fiber sheets bonded with epoxy resin. v Initially a thorough literature review on shear of reinforced concrete beams with and without external FRP strengthening was performed, paying special attention to the acting mechanisms studied to date, which allowed the study of the most important models both to describe the bond phenomenon as well as calculating the FRP shear contribution, through separate databases of pull-out tests and shear tests on reinforced concrete beams externally strengthened with FRP. Based on above, they were exposed the acting mechanisms in a FRP shear strengthening on reinforced concrete beams and how guidelines deal the topic. The same way, it is defined a FRP stress strength model and two more models are proposed for calculating the effective stress, one of these is based on the Oller (2005) bond model and another one is the data best fit, taking into account most of the acting mechanisms. To complement the theoretical part we develop an experimental program that, in addition to providing more records to the meager existing database provide greater understanding to the points considered poorly resolved. The test program included 32 tests of 16 beams (2 per beam) of 4.5 m long, shear strengthened with FRP, externally. Finally, modifications to the existing codes and guidelines are proposed.
Resumo:
El uso de materiales compuestos para el refuerzo, reparación y rehabilitación de estructuras de hormigón se ha convertido en una técnica muy utilizada en la última década. Con independencia de la técnica del refuerzo, uno de los principales condicionantes del diseño es el fallo de la adherencia entre el hormigón y el material compuesto, atribuida generalmente a las tensiones en la interfaz de estos materiales. Las propiedades mecánicas del hormigón y de los materiales compuestos son muy distintas. Los materiales compuestos comúnmente utilizados en ingeniería civil poseen alta resistencia a tracción y tienen un comportamiento elástico y lineal hasta la rotura, lo cual, en contraste con el ampliamente conocido comportamiento del hormigón, genera una clara incompatibilidad para soportar esfuerzos de forma conjunta. Esta incompatibilidad conduce a fallos relacionados con el despegue del material compuesto del sustrato de hormigón. En vigas de hormigón reforzadas a flexión o a cortante, el despegue del material compuesto es un fenómeno que frecuentemente condiciona la capacidad portante del elemento. Existen dos zonas potenciales de iniciación del despegue: los extremos y la zona entre fisuras de flexión o de flexión-cortante. En el primer caso, la experiencia a través de los últimos años ha demostrado que se puede evitar prolongando el refuerzo hasta los apoyos o mediante el empleo de algún sistema de anclaje. Sin embargo, las recomendaciones para evitar el segundo caso de despegue aún se encuentran lejos de poder prever el fallo de forma eficiente. La necesidad de medir la adherencia experimentalmente de materiales FRP adheridos al hormigón ha dado lugar a desarrollar diversos métodos por la comunidad de investigadores. De estas campañas experimentales surgieron modelos para el pronóstico de la resistencia de adherencia, longitud efectiva y relación tensión-deslizamiento. En la presente tesis se propone un ensayo de beam-test, similar al utilizado para medir la adherencia de barras de acero, para determinar las características de adherencia del FRP al variar la resistencia del hormigón y el espesor del adhesivo. A la vista de los resultados, se considera que este ensayo puede ser utilizado para investigar diferentes tipos de adhesivos y otros métodos de aplicación, dado que representa con mayor realidad el comportamiento en vigas reforzadas. Los resultados experimentales se trasladan a la comprobación del fallo por despegue en la región de fisuras de flexión o flexión cortante en vigas de hormigón presentando buena concordancia. Los resultados condujeron a la propuesta de que la limitación de la deformación constituye una alternativa simple y eficiente para prever el citado modo de fallo. Con base en las vigas analizadas, se propone una nueva expresión para el cálculo de la limitación de la deformación del laminado y se lleva a cabo una comparación entre los modelos existentes mediante un análisis estadístico para evaluar su precisión. Abstract The use of composite materials for strengthening, repairing or rehabilitating concrete structures has become more and more popular in the last ten years. Irrespective of the type of strengthening used, design is conditioned, among others, by concrete-composite bond failure, normally attributed to stresses at the interface between these two materials. The mechanical properties of concrete and composite materials are very different. Composite materials commonly used in civil engineering possess high tensile strength (both static and long term) and they are linear elastic to failure, which, in contrast to the widely known behavior of concrete, there is a clear incompatibility which leads to bond-related failures. Bond failure in the composite material in bending- or shear-strengthened beams often controls bearing capacity of the strengthened member. Debonding failure of RC beams strengthened in bending by externally-bonded composite laminates takes place either, at the end (plate end debonding) or at flexure or flexure-shear cracks (intermediate crack debonding). In the first case, the experience over the past years has shown that this can be avoided by extending laminates up to the supports or by using an anchoring system. However, recommendations for the second case are still considered far from predicting failure efficiently. The need to experimentally measure FRP bonding to concrete has induced the scientific community to develop test methods for that purpose. Experimental campaigns, in turn, have given rise to models for predicting bond strength, effective length and the stress-slip relationship. The beam-type test proposed and used in this thesis to determine the bonding characteristics of FRP at varying concrete strengths and adhesive thicknesses was similar to the test used for measuring steel reinforcement to concrete bonding conditions. In light of the findings, this test was deemed to be usable to study different types of adhesives and application methods, since it reflects the behavior of FRP in strengthened beams more accurately than the procedures presently in place. Experimental results are transferred to the verification of peeling-off at flexure or flexure-shear cracks, presenting a good general agreement. Findings led to the conclusion that the strain limitation of laminate produces accurate predictions of intermediate crack debonding. A new model for strain limitation is proposed. Finally, a comprehensive evaluation based on a statistical analysis among existing models is carried out in order to assess their accuracy.
Resumo:
Los nudos son los defectos que más disminuyen la resistencia de piezas de madera en la escala estructural, al ocasionar no solo una discontinuidad material, sino también la desviación de las fibras que se encuentran a su alrededor. En la década de los 80 se introdujo la teoría de la analogía fluido-fibra, como un método que aproximaba adecuadamente todas estas desviaciones. Sin embargo en su aplicación tridimensional, nunca se consideraron las diferencias geométricas en el sentido perpendicular al eje longitudinal de las piezas estructurales, lo cual imposibilitaba la simulación numérica de algunos de los principales tipos de nudos, y disminuía la precisión obtenida en aquellos nudos en los que la modelización sí era viable. En este trabajo se propone un modelo programado en lenguaje paramétrico de un software de elementos finitos que, bajo una formulación en tres dimensiones más general, permitirá estudiar de forma automatizada el comportamiento estructural de la madera bajo la influencia de los principales tipos de nudos, a partir de la geometría visible de los mismos y la posición de la médula en la pieza, y el cual ha sido contrastado experimentalmente, simulando de forma muy precisa el comportamiento mecánico de vigas sometidas a ensayos de flexión a cuatro puntos. Knots are the defects that most reduce the strength of lumber at the structural level, by causing not only a material discontinuity but also the deviation of the fibers that surround them. In the 80's it was introduced the theory of the flow-grain analogy as a method to approximating adequately these deviations. However, in three-dimensional applications, geometrical differences in the direction perpendicular to the longitudinal axis of the structural specimens were never considered before, which prevented the numerical simulation of some of the main types of knots, and decreased the achieved precision in those kind of knots where modeling itself was possible. This paper purposes a parametric model programmed in a finite element software, in the way that with a more general three-dimensional formulation, an automated study of the structural behavior of timber under the influence of the main types of knots is allowed by only knowing the visible geometry of such defects, and the position of the pith. Furthermore that has been confirmed experimentally obtaining very accurately simulations of the mechanical behavior of beams under four points bending test.