29 resultados para Materiali compositi, CFRP, Combined Loading Compression (CLC) test method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanical response under compression of LiF single crystal micropillars oriented in the [111] direction was studied. Micropillars of different diameter (in the range 1–5 lm) were obtained by etching the matrix in directionally-solidified NaCl–LiF and KCl–LiF eutectic compounds. Selected micropillars were exposed to high-energy Ga+ ions to ascertain the effect of ion irradiation on the mechanical response. Ion irradiation led to an increase of approximately 30% in the yield strength and the maximum compressive strength but no effect of the micropillar diameter on flow stress was found in either the as-grown or the ion irradiated pillars. The dominant deformation micromechanisms were analyzed by means of crystal plasticity finite element simulations of the compression test, which explained the strong effect of micropillar misorientation on the mechanical response. Finally, the lack of size effect on the flow stress was discussed to the light of previous studies in LiF and other materials which show high lattice resistance to dislocation motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El hormigón es uno de los materiales de construcción más empleados en la actualidad debido a sus buenas prestaciones mecánicas, moldeabilidad y economía de obtención, entre otras ventajas. Es bien sabido que tiene una buena resistencia a compresión y una baja resistencia a tracción, por lo que se arma con barras de acero para formar el hormigón armado, material que se ha convertido por méritos propios en la solución constructiva más importante de nuestra época. A pesar de ser un material profusamente utilizado, hay aspectos del comportamiento del hormigón que todavía no son completamente conocidos, como es el caso de su respuesta ante los efectos de una explosión. Este es un campo de especial relevancia, debido a que los eventos, tanto intencionados como accidentales, en los que una estructura se ve sometida a una explosión son, por desgracia, relativamente frecuentes. La solicitación de una estructura ante una explosión se produce por el impacto sobre la misma de la onda de presión generada en la detonación. La aplicación de esta carga sobre la estructura es muy rápida y de muy corta duración. Este tipo de acciones se denominan cargas impulsivas, y pueden ser hasta cuatro órdenes de magnitud más rápidas que las cargas dinámicas impuestas por un terremoto. En consecuencia, no es de extrañar que sus efectos sobre las estructuras y sus materiales sean muy distintos que las que producen las cargas habitualmente consideradas en ingeniería. En la presente tesis doctoral se profundiza en el conocimiento del comportamiento material del hormigón sometido a explosiones. Para ello, es crucial contar con resultados experimentales de estructuras de hormigón sometidas a explosiones. Este tipo de resultados es difícil de encontrar en la literatura científica, ya que estos ensayos han sido tradicionalmente llevados a cabo en el ámbito militar y los resultados obtenidos no son de dominio público. Por otra parte, en las campañas experimentales con explosiones llevadas a cabo por instituciones civiles el elevado coste de acceso a explosivos y a campos de prueba adecuados no permite la realización de ensayos con un elevado número de muestras. Por este motivo, la dispersión experimental no es habitualmente controlada. Sin embargo, en elementos de hormigón armado sometidos a explosiones, la dispersión experimental es muy acusada, en primer lugar, por la propia heterogeneidad del hormigón, y en segundo, por la dificultad inherente a la realización de ensayos con explosiones, por motivos tales como dificultades en las condiciones de contorno, variabilidad del explosivo, o incluso cambios en las condiciones atmosféricas. Para paliar estos inconvenientes, en esta tesis doctoral se ha diseñado un novedoso dispositivo que permite ensayar hasta cuatro losas de hormigón bajo la misma detonación, lo que además de proporcionar un número de muestras estadísticamente representativo, supone un importante ahorro de costes. Con este dispositivo se han ensayado 28 losas de hormigón, tanto armadas como en masa, de dos dosificaciones distintas. Pero además de contar con datos experimentales, también es importante disponer de herramientas de cálculo para el análisis y diseño de estructuras sometidas a explosiones. Aunque existen diversos métodos analíticos, hoy por hoy las técnicas de simulación numérica suponen la alternativa más avanzada y versátil para el cálculo de elementos estructurales sometidos a cargas impulsivas. Sin embargo, para obtener resultados fiables es crucial contar con modelos constitutivos de material que tengan en cuenta los parámetros que gobiernan el comportamiento para el caso de carga en estudio. En este sentido, cabe destacar que la mayoría de los modelos constitutivos desarrollados para el hormigón a altas velocidades de deformación proceden del ámbito balístico, donde dominan las grandes tensiones de compresión en el entorno local de la zona afectada por el impacto. En el caso de los elementos de hormigón sometidos a explosiones, las tensiones de compresión son mucho más moderadas, siendo las tensiones de tracción generalmente las causantes de la rotura del material. En esta tesis doctoral se analiza la validez de algunos de los modelos disponibles, confirmando que los parámetros que gobiernan el fallo de las losas de hormigón armado ante explosiones son la resistencia a tracción y su ablandamiento tras rotura. En base a los resultados anteriores se ha desarrollado un modelo constitutivo para el hormigón ante altas velocidades de deformación, que sólo tiene en cuenta la rotura por tracción. Este modelo parte del de fisura cohesiva embebida con discontinuidad fuerte, desarrollado por Planas y Sancho, que ha demostrado su capacidad en la predicción de la rotura a tracción de elementos de hormigón en masa. El modelo ha sido modificado para su implementación en el programa comercial de integración explícita LS-DYNA, utilizando elementos finitos hexaédricos e incorporando la dependencia de la velocidad de deformación para permitir su utilización en el ámbito dinámico. El modelo es estrictamente local y no requiere de remallado ni conocer previamente la trayectoria de la fisura. Este modelo constitutivo ha sido utilizado para simular dos campañas experimentales, probando la hipótesis de que el fallo de elementos de hormigón ante explosiones está gobernado por el comportamiento a tracción, siendo de especial relevancia el ablandamiento del hormigón. Concrete is nowadays one of the most widely used building materials because of its good mechanical properties, moldability and production economy, among other advantages. As it is known, it has high compressive and low tensile strengths and for this reason it is reinforced with steel bars to form reinforced concrete, a material that has become the most important constructive solution of our time. Despite being such a widely used material, there are some aspects of concrete performance that are not yet fully understood, as it is the case of its response to the effects of an explosion. This is a topic of particular relevance because the events, both intentional and accidental, in which a structure is subjected to an explosion are, unfortunately, relatively common. The loading of a structure due to an explosive event occurs due to the impact of the pressure shock wave generated in the detonation. The application of this load on the structure is very fast and of very short duration. Such actions are called impulsive loads, and can be up to four orders of magnitude faster than the dynamic loads imposed by an earthquake. Consequently, it is not surprising that their effects on structures and materials are very different than those that cause the loads usually considered in engineering. This thesis broadens the knowledge about the material behavior of concrete subjected to explosions. To that end, it is crucial to have experimental results of concrete structures subjected to explosions. These types of results are difficult to find in the scientific literature, as these tests have traditionally been carried out by armies of different countries and the results obtained are classified. Moreover, in experimental campaigns with explosives conducted by civil institutions the high cost of accessing explosives and the lack of proper test fields does not allow for the testing of a large number of samples. For this reason, the experimental scatter is usually not controlled. However, in reinforced concrete elements subjected to explosions the experimental dispersion is very pronounced. First, due to the heterogeneity of concrete, and secondly, because of the difficulty inherent to testing with explosions, for reasons such as difficulties in the boundary conditions, variability of the explosive, or even atmospheric changes. To overcome these drawbacks, in this thesis we have designed a novel device that allows for testing up to four concrete slabs under the same detonation, which apart from providing a statistically representative number of samples, represents a significant saving in costs. A number of 28 slabs were tested using this device. The slabs were both reinforced and plain concrete, and two different concrete mixes were used. Besides having experimental data, it is also important to have computational tools for the analysis and design of structures subjected to explosions. Despite the existence of several analytical methods, numerical simulation techniques nowadays represent the most advanced and versatile alternative for the assessment of structural elements subjected to impulsive loading. However, to obtain reliable results it is crucial to have material constitutive models that take into account the parameters that govern the behavior for the load case under study. In this regard it is noteworthy that most of the developed constitutive models for concrete at high strain rates arise from the ballistic field, dominated by large compressive stresses in the local environment of the area affected by the impact. In the case of concrete elements subjected to an explosion, the compressive stresses are much more moderate, while tensile stresses usually cause material failure. This thesis discusses the validity of some of the available models, confirming that the parameters governing the failure of reinforced concrete slabs subjected to blast are the tensile strength and softening behaviour after failure. Based on these results we have developed a constitutive model for concrete at high strain rates, which only takes into account the ultimate tensile strength. This model is based on the embedded Cohesive Crack Model with Strong Discontinuity Approach developed by Planas and Sancho, which has proved its ability in predicting the tensile fracture of plain concrete elements. The model has been modified for its implementation in the commercial explicit integration program LS-DYNA, using hexahedral finite elements and incorporating the dependence of the strain rate, to allow for its use in dynamic domain. The model is strictly local and does not require remeshing nor prior knowledge of the crack path. This constitutive model has been used to simulate two experimental campaigns, confirming the hypothesis that the failure of concrete elements subjected to explosions is governed by their tensile response, being of particular relevance the softening behavior of concrete.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the effective width of reinforced concrete flat slab structures subjected to seismic loading on the basis of dynamic shaking table tests. The study is focussed on the behavior of corner slab? column connections with structural steel I- or channel-shaped sections (shearheads) as shear punching reinforcement. To this end, a 1/2 scale test model consisting of a flat slab supported on four box-type steel columns was subjected to several seismic simulations of increasing intensity. It is found from the test results that the effective width tends to increase with the intensity of the seismic simulation, and this increase is limited by the degradation of adherence between reinforcing steel and concrete induced by the strain reversals caused by the earthquake. Also, significant differences are found between the effective width obtained from the tests and the values predicted by formula proposed in the literature. These differences are attributed to the stiffening effect provided by the steel profiles that constitute the punching shear reinforcement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research investigates the ultimate earthquake resistance of typical RC moment resisting frames designed accordingly to current standards, in terms of ultimate energy absorption/dissipation capacity. Shake table test of a 2/5 scale model, under several intensities of ground motion, are carried out. The loading effect of the earthquake is expressed as the total energy that the quake inputs to the structure, and the seismic resistance is interpreted as the amount of energy that the structure dissipates in terms of cumulative inelastic strain energy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Permanently bonded onto a structure, an integrated Phased Array (PhA II) transducer that can provide reliable electromechanical connection with corresponding sophisticated miniaturized ?all in one? SHM electronic device installed directly above it, without need for any interface cabling, during all aerospace structure lifecycle phases and for a huge variety of real harsh service environments of structures to be monitored is presented. This integrated PhA II transducer [1], as a key component of the PAMELA SHM? (Phased Array Monitoring for Enhanced Life Assessment) system, has two principal tasks at the same time, reliably transceive elastic waves in real aerospace service environments and serves as a reliable sole carrier or support for associated integrated on-board SHM electronic device attached above. The PhA II transducer successfully accomplished both required task throughout extensive test campaigns which included low to high temperature tests, temperature cycling, mechanical loading, combined thermo- mechanical loading and vibration resistance, etc. both with and without SHM device attached above due to RTCA DO-160F.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El refuerzo de estructuras existentes mediante el encolado exterior de láminas de polímeros reforzados con fibras (FRP) se ha convertido en la aplicación más común de los materiales compuestos avanzados en construcción. Estos materiales presentan muchas ventajas frente a los materiales convencionales (sin corrosión, ligeros, de fácil aplicación, etc.). Pero a pesar de las numerosas investigaciones realizadas, aún persisten ciertas dudas sobre algunos aspectos de su comportamiento y las aplicaciones prácticas se llevan a cabo sólo con la ayuda de guías, sin que haya una normativa oficial. El objetivo de este trabajo es incrementar el conocimiento sobre esta técnica de refuerzo, y más concretamente, sobre el refuerzo a flexión de estructuras de fábrica. Con frecuencia el elemento reforzado es de hormigón armado y las láminas de FRP encoladas al exterior sirven para mejorar su resistencia a flexión, cortante o compresión (encamisados). Sin embargo su empleo en otros materiales como las estructuras de fábrica resulta muy prometedor. Las fábricas se caracterizan por soportar muy bien los esfuerzos de compresión pero bastante mal los de tracción. Adherir láminas de materiales compuestos puede servir para mejorar la capacidad resistente de elementos de fábrica sometidos a esfuerzos de flexión. Pero para ello, debe quedar garantizada una correcta adherencia entre el FRP y la fábrica, especialmente en edificios antiguos cuya superficie puede estar deteriorada por encontrarse a la intemperie o por el propio paso del tiempo. En el capítulo II se describen los objetivos fundamentales del trabajo y el método seguido. En el capítulo III se hace una amplia revisión del estado de conocimiento sobre el tema. En el apartado III.1 se detallan las principales características y propiedades mecánicas de fibras, matrices y materiales compuestos así como sus principales aplicaciones, haciendo especial hincapié en aspectos relativos a su durabilidad. En el apartado III.2 se incluye una revisión histórica de las líneas de investigación, tanto teóricas como empíricas, publicadas sobre estructuras de hormigón reforzadas a flexión encolando materiales compuestos. El apartado III.3 se centra en el aspecto fundamental de la adherencia refuerzo-soporte. Se hace un repaso a distintos modelos propuestos para prevenir el despegue distinguiendo si éste se inicia en la zona de anclaje o si está inducido por fisuras en la zona interior del elemento. Se observa falta de consenso en las propuestas. Además en este punto se relatan las campañas experimentales publicadas acerca de la adherencia entre materiales compuestos y fábricas. En el apartado III.4 se analizan las particularidades de las estructuras de fábrica. Además, se revisan algunas de las investigaciones relativas a la mejora de su comportamiento a flexión mediante láminas de FRP. El comportamiento mecánico de muros reforzados solicitados a flexión pura (sin compresión) ha sido documentado por varios autores, si bien es una situación poco frecuente en fábricas reales. Ni el comportamiento mecánico de muros reforzados solicitados a flexocompresión ni la incidencia que el nivel de compresión soportado por la fábrica tiene sobre la capacidad resistente del elemento reforzado han sido suficientemente tratados. En cuanto a los trabajos teóricos, las diferentes propuestas se basan en los métodos utilizados para hormigón armado y comparten los principios habituales de cálculo. Sin embargo, presentan diferencias relativas, sobre todo, a tres aspectos: 1) la forma de modelar el comportamiento de la fábrica, 2) el valor de deformación de cálculo del refuerzo, y 3) el modo de fallo que se considera recomendable buscar con el diseño. A pesar de ello, el ajuste con la parte experimental de cada trabajo suele ser bueno debido a una enorme disparidad en las variables consideradas. Cada campaña presenta un modo de fallo característico y la formulación que se propone resulta apropiada para él. Parece necesario desarrollar un método de cálculo para fábricas flexocomprimidas reforzadas con FRP que pueda ser utilizado para todos los posibles fallos, tanto atribuibles a la lámina como a la fábrica. En el apartado III.4 se repasan algunas lesiones habituales en fábricas solicitadas a flexión y se recogen ejemplos de refuerzos con FRP para reparar o prevenir estos daños. Para mejorar el conocimiento sobre el tema, se llevan a cabo dos pequeñas campañas experimentales realizadas en el Instituto de Ciencias de la Construcción Eduardo Torroja. La primera acerca de la adherencia de materiales compuestos encolados a fábricas deterioradas (apartado IV.1) y la segunda sobre el comportamiento estructural a flexocompresión de probetas de fábrica reforzadas con estos materiales (apartado IV.2). En el capítulo V se analizan algunos de los modelos de adherencia propuestos para prevenir el despegue del extremo del refuerzo. Se confirma que las predicciones obtenidas con ellos resultan muy dispares. Se recopila una base de datos con los resultados experimentales de campañas sobre adherencia de FRP a fábricas extraídas de la literatura y de los resultados propios de la campaña descrita en el punto IV.1. Esta base de datos permite conocer cual de los métodos analizados resulta más adecuado para dimensionar el anclaje de láminas de FRP adheridas a fábricas. En el capítulo VI se propone un método para la comprobación en agotamiento de secciones de fábrica reforzadas con materiales compuestos sometidas a esfuerzos combinados de flexión y compresión. Está basado en el procedimiento de cálculo de la capacidad resistente de secciones de hormigón armado pero adaptado a las fábricas reforzadas. Para ello, se utiliza un diagrama de cálculo tensión deformación de la fábrica de tipo bilineal (acorde con el CTE DB SE-F) cuya simplicidad facilita el desarrollo de toda la formulación al tiempo que resulta adecuado para predecir la capacidad resistente a flexión tanto para fallos debidos al refuerzo como a la fábrica. Además se limita la deformación de cálculo del refuerzo teniendo en consideración ciertos aspectos que provocan que la lámina adherida no pueda desarrollar toda su resistencia, como el desprendimiento inducido por fisuras en el interior del elemento o el deterioro medioambiental. En concreto, se propone un “coeficiente reductor por adherencia” que se determina a partir de una base de datos con 68 resultados experimentales procedentes de publicaciones de varios autores y de los ensayos propios de la campaña descrita en el punto IV.2. También se revisa la formulación propuesta con ayuda de la base de datos. En el capítulo VII se estudia la incidencia de las principales variables, como el axil, la deformación de cálculo del refuerzo o su rigidez, en la capacidad final del elemento. Las conclusiones del trabajo realizado y las posibles líneas futuras de investigación se exponen en el capítulo VIII. ABSTRACT Strengthening of existing structures with externally bonded fiber reinforced polymers (FRP) has become the most common application of advanced composite materials in construction. These materials exhibit many advantages in comparison with traditional ones (corrosion resistance, light weight, easy to apply, etc.). But despite countless researches have been done, there are still doubts about some aspects of their behaviour and applications are carried out only with the help of guidelines, without official regulations. The aim of this work is to improve the knowledge on this retrofitting technique, particularly in regard to flexural strengthening of masonry structures. Reinforced concrete is often the strengthened material and external glued FRP plates are used to improve its flexural, shear or compressive (by wrapping) capacity. However the use of this technique on other materials like masonry structures looks promising. Unreinforced masonry is characterized for being a good material to support compressive stresses but really bad to withstand tensile ones. Glue composite plates can improve the flexural capacity of masonry elements subject to bending. But a proper bond between FRP sheet and masonry must be ensured to do that, especially in old buildings whose surface can be damaged due to being outside or ageing. The main objectives of the work and the methodology carried out are described In Chapter II. An extensive overview of the state of art is done in Chapter III. In Section III.1 physical and mechanical properties of fibers, matrix and composites and their main applications are related. Durability aspects are especially emphasized. Section III.2 includes an historical overview of theoretical and empirical researches on concrete structures strengthened gluing FRP plates to improve their flexural behaviour. Section III.3 focuses on the critical point of bonding between FRP and substrate. Some theoretical models to prevent debonding of FRP laminate are reviewed, it has made a distinction between models for detachment at the end of the plate or debonding in the intermediate zones due to the effects of cracks. It is observed a lack of agreement in the proposals. Some experimental studies on bonding between masonry and FRP are also related in this chapter. The particular characteristics of masonry structures are analyzed in Section III.4. Besides some empirical and theoretical investigations relative to improve their flexural capacity with FRP sheets are reviewed. The mechanical behaviour of strengthened walls subject to pure bending (without compression) has been established by several authors, but this is an unusual situation for real masonry. Neither mechanical behaviour of walls subject to bending and compression nor influence of axial load in the final capacity of the strengthened element are adequately studied. In regard to theoretical studies, the different proposals are based on reinforced concrete analytical methods and share common design principles. However, they present differences, especially, about three aspects: 1) the constitutive law of masonry, 2) the value of ultimate FRP strain and 3) the desirable failure mode that must be looked for. In spite of them, a good agreement between each experimental program and its theoretical study is often exhibited due to enormous disparity in considered test parameters. Each experimental program usually presents a characteristic failure mode and the proposed formulation results appropriate for this one. It seems necessary to develop a method for FRP strengthened walls subject to bending and compression enable for all failure modes (due to FRP or masonry). Some common damages in masonry subject to bending are explained in Section III.4. Examples of FRP strengthening to repair or prevent these damages are also written. Two small experimental programs are carried out in Eduardo Torroja Institute to improve the knowledge on this topic. The first one is concerned about the bond between FRP plates and damaged masonry (section IV.1) and the second one is related to the mechanical behaviour of the strengthened masonry specimens subject to out of plane bending combined with axial force (section IV.2). In the Chapter V some bond models to prevent the debonding at the FRP plate end are checked. It is confirmed that their predictions are so different. A pure-shear test database is compiled with results from the existing literature and others from the experimental program described in section IV.1. This database lets know which of the considered model is more suitable to design anchorage lengths of glued FRP to masonry. In the Chapter VI a method to check unreinforced masonry sections with external FRP strengthening subject to bending and compression to the ultimate limit state is proposed. This method is based on concrete reinforced one, but it is adapted to strengthened masonry. A bilinear constitutive law is used for masonry (according to CTE DB SE-F). Its simplicity helps to develop the model formulation and it has proven to be suitable to predict bending capacity either for FRP failures or masonry crushing. With regard to FRP, the design strain is limited. It is taken into account different aspects which cause the plate can’t reach its ultimate strength, like intermediate FRP debonding induced by opening cracking or environmental damage. A “bond factor” is proposed. It is obtained by means of an experimental bending test database that includes 68 results from the existing literature and from the experimental program described in section IV.2. The proposed formulation has also been checked with the help of bending database. The effects of the main parameters, like axial load, FRP design effective strain or FRP stiffness, on the bending capacity of the strengthened element are studied in Chapter VII. Finally, the main conclusions from the work carried out are summarized in Chapter VIII. Future lines of research to be explored are suggested as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical damage to fruits results from a combination of fruit properties and of damage inflicting effects by the handling equipment. Treatments were applied to fruits which affect mechanical damage susceptibility: precooling for stone fruits and degreening to citrus fruits. Laboratory tests (compression, impact, tumbling, abrasion) and field tests (damage in the handling lines) were applied to (3) peach, (2) apricot, (2) orange and (1) lemon varieties. Hydroor-air-cooling influence positively peach and apricot firmness and cause a significant reduction in: number of bruised fruits, and size of visible bruise, when combined with a low level of loading during handling. Degreening also affects the resistance of citrus fruits to handling, when compared to green fruits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thermal and mechanical behaviour of isotactic polypropylene (iPP) nanocomposites reinforced with different loadings of inorganic fullerene-like tungsten disulfide (IF-WS2) nanoparticles was investigated. The IF-WS2 noticeably enhanced the polymer stiffness and strength, ascribed to their uniform dispersion, the formation of a large nanoparticle?matrix interface combined with a nucleating effect on iPP crystallization. Their reinforcement effect was more pronounced at high temperatures. However, a drop in ductility and toughness was found at higher IF-WS2 concentrations. The tensile behaviour of the nanocomposites was extremely sensitive to the strain rate and temperature, and their yield strength was properly described by the Eyring s equation. The activation energy increased while the activation volume decreased with increasing nanoparticle loading, indicating a reduction in polymer chain motion. The nanoparticles improved the thermomechanical properties of iPP: raised the glass transition and heat deflection temperatures while decreased the coefficient of thermal expansion. The nanocomposites also displayed superior flame retardancy with longer ignition time and reduced peak heat release rate. Further, a gradual rise in thermal conductivity was found with increasing IF-WS2 loading both in the glassy and rubbery states. The results presented herein highlight the benefits and high potential of using IF-nanoparticles for enhancing the thermomechanical properties of thermoplastic polymers compared to other nanoscale fillers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of the temperature on the compressive stress–strain behavior of Al/SiC nanoscale multilayers was studied by means of micropillar compression tests at 23 °C and 100 °C. The multilayers (composed of alternating layers of 60 nm in thickness of nanocrystalline Al and amorphous SiC) showed a very large hardening rate at 23 °C, which led to a flow stress of 3.1 ± 0.2 GPa at 8% strain. However, the flow stress (and the hardening rate) was reduced by 50% at 100 °C. Plastic deformation of the Al layers was the dominant deformation mechanism at both temperatures, but the Al layers were extruded out of the micropillar at 100 °C, while Al plastic flow was constrained by the SiC elastic layers at 23 °C. Finite element simulations of the micropillar compression test indicated the role played by different factors (flow stress of Al, interface strength and friction coefficient) on the mechanical behavior and were able to rationalize the differences in the stress–strain curves between 23 °C and 100 °C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La actuación de cargas sobre un suelo saturado, produce, en función de la naturaleza de la solicitación, del tipo de suelo y de las condiciones de drenaje del terreno, un incremento de la presión sobre el agua de los intersticios. Se ha abordado el estudio de la generación de dicha presión intersticial a partir de muestras de suelo blando, normalmente consolidadas, procedentes del subsuelo del Puerto de Barcelona. Para ello se han utilizado los datos de una completa campaña experimental utilizando la máquina de ensayo de corte simple, y tras la adecuada interpretación del ensayo, se identifican los aspectos que se consideran clave para el proceso de generación de presión intersticial en el suelo, según las diferentes situaciones de carga actuante. Como conclusión, se plantea la generalización de la clásica ecuación que Skempton formuló hace casi 60 años y que permite interpretar la generación de presión intersticial para el aparato de ensayo triaxial. ncrease in pore pressure depending on the nature of the excitation, the type of soil and the drainage conditions of the ground are generated by loads acting on a saturated soil. It has approached the study of the generation of the pore pressure from usually consolidated soft soil samples from the basement of the Port of Barcelona. Data from an adequate experimental campaign using simple shear machine have been used, and the aspects that are considered key to the process of generation of pore pressure in the soil under different loading conditions acting have been identified. In conclusion, the generalization of Skempton's classical equation (formulated almost 60 years ago) and the interpretation of the pore pressure generation for triaxial test apparatus have been proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The latest technology and architectural trends have significantly improved the use of a large variety of glass products in construction which, in function of their own characteristocs, allow to design and calculate structural glass elements under safety conditions. This paper presents the evaluation and analysis of the damping properties of rectangular laminated glass plates of 1.938 m x 0.876 m with different thickness depending on the number of PVB interlayers arranged. By means of numerical simulation and experimental verification, using modal analysis, natural frequencies and damping of the glass plates were calculated, both under free boundary conditions and operational conditions for the impact test equipment used in the experimental program, as the European standard UNE-EN 12600:2003 specifies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper reports on a collaborative effort between the Swiss Federal Nuclear Safety Inspectorate (ENSI) and their consultants Principia and Stangenberg. As part of the IMPACT III project, reduced scale impact tests of reinforced concrete structures were carried out. The simulation of test X3 is presented here and the numerical results are compared with those obtained in the test, carried out in August 2013. The general object is to improve the safety of nuclear facilities and, more specifically, to demonstrate the capabilities of current simulation techniques to reproduce the behaviour of a reinforced concrete structure impacted by a soft missile. The missile is a steel tube with a mass of 50 kg and travelling at 140 m/s. The target is a 250 mm thick, 2,1 m by 2,1 m reinforced concrete wall, held in a stiff supporting frame. The reinforcement includes both longitudinal and transverse rebars. Calculations were carried out before and after the test with Abaqus (Principia) and SOFiSTiK (Stangenberg). In the Abaqus simulation the concrete is modelled using solid elements and a damaged plasticity formulation, the rebars with embedded beam elements, and the missile with shell elements. In SOFiSTiK the target is modelled with non-linear, layered shell elements for the reinforcement on both sides; non-linear shear deformations of shell/plate elements are approximately included. The results generally indicate a good agreement between calculations and measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El desarrollo de nuevas estructuras aeroespaciales optimizadas, utilizan materiales compuestos, para los componentes críticos y subsistemas, principalmente polímeros reforzados con fibra de carbono (CFRP). Un conocimiento profundo del estado de daño por fatiga de estructuras de CFRP avanzado, es esencial para predecir la vida residual y optimizar los intervalos de inspección estructural, reparaciones y/o sustitución de componentes. Las técnicas actuales se basan principalmente en la medición de cargas estructurales a lo largo de la vida útil de la estructura mediante galgas extensométricas eléctricas. Con esos datos, se estima la vida a fatiga utilizando modelos de acumulación de daño. En la presente tesis, se evalúa la metodología convencional para la estimación de la vida a fatiga de un CFRP aeronáutico. Esta metodología está basada en la regla de acumulación de daño lineal de Palmgren-Miner, y es aplicada para determinar la vida a fatiga de estructuras sometidas a cargas de amplitud variable. Se ha realizado una campaña de ensayos con cargas de amplitud constante para caracterizar un CFRP aeronáutico a fatiga, obteniendo las curvas clásicas S-N, en diferentes relaciones de esfuerzo. Se determinaron los diagramas de vida constante, (CLD), también conocidos como diagramas de Goodman, utilizando redes neuronales artificiales debido a la ausencia de modelos coherentes para materiales compuestos. Se ha caracterizado la degradación de la rigidez debido al daño por fatiga. Se ha ensayado un segundo grupo de probetas con secuencias estandarizadas de cargas de amplitud variable, para obtener la vida a fatiga y la degradación de rigidez en condiciones realistas. Las cargas aplicadas son representativas de misiones de aviones de combate (Falstaff), y de aviones de transporte (Twist). La vida a fatiga de las probetas cicladas con cargas de amplitud variable, se comparó con el índice de daño teórico calculado en base a la regla de acumulación de daño lineal convencional. Los resultados obtenidos muestran predicciones no conservativas. Esta tesis también presenta el estudio y desarrollo, de una nueva técnica de no contacto para evaluar el estado de daño por fatiga de estructuras de CFRP por medio de cambios de los parámetros de rugosidad. La rugosidad superficial se puede medir fácilmente en campo con métodos sin contacto, mediante técnicas ópticas tales como speckle y perfilómetros ópticos. En el presente estudio, se han medido parámetros de rugosidad superficial, y el factor de irregularidad de la superficie, a lo largo de la vida de las probetas cicladas con cargas de amplitud constante y variable, Se ha obtenido una buena tendencia de ajuste al correlacionar la magnitud de la rugosidad y el factor de irregularidad de la superficie con la degradación de la rigidez de las probetas fatigadas. Estos resultados sugieren que los cambios en la rugosidad superficial medida en zonas estratégicas de componentes y estructuras hechas de CFRP, podrían ser indicativas del nivel de daño interno debido a cargas de fatiga. Los resultados también sugieren que el método es independiente del tipo de carga de fatiga que ha causado el daño. Esto último hace que esta técnica de medición sea aplicable como inspección para una amplia gama de estructuras de materiales compuestos, desde tanques presurizados con cargas de amplitud constante, estructuras aeronáuticas como alas y colas de aeronaves cicladas con cargas de amplitud variable, hasta aplicaciones industriales como automoción, entre otros. ABSTRACT New optimized aerospace structures use composite materials, mainly carbon fiber reinforced polymer composite (CFRP), for critical components and subsystems. A strong knowledge of the fatigue state of highly advanced (CFRP) structures is essential to predict the residual life and optimize intervals of structural inspection, repairs, and/or replacements. Current techniques are based mostly on measurement of structural loads throughout the service life by electric strain gauge sensors. These sensors are affected by extreme environmental conditions and by fatigue loads in such a way that the sensors and their systems require exhaustive maintenance throughout system life. In the present thesis, the conventional methodology based on linear damage accumulation rules, applied to determine the fatigue life of structures subjected to variable amplitude loads was evaluated for an aeronautical CFRP. A test program with constant amplitude loads has been performed to obtain the classical S-N curves at different stress ratios. Constant life diagrams, CLDs, where determined by means of Artificial Neural Networks due to the absence of consistent models for composites. The stiffness degradation due to fatigue damage has been characterized for coupons under cyclic tensile loads. A second group of coupons have been tested until failure with a standardized sequence of variable amplitude loads, representative of missions for combat aircraft (Falstaff), and representative of commercial flights (Twist), to obtain the fatigue life and the stiffness degradation under realistic conditions. The fatigue life of the coupons cycled with variable amplitude loads were compared to the theoretical damage index calculated based on the conventional linear damage accumulation rule. The obtained results show non-conservative predictions. This thesis also presents the evaluation of a new non-contact technique to evaluate the fatigue damage state of CFRP structures by means of measuring roughness parameters to evaluate changes in the surface topography. Surface roughness can be measured easily on field with non-contact methods by optical techniques such as speckle and optical perfilometers. In the present study, surface roughness parameters, and the surface irregularity factor, have been measured along the life of the coupons cycled with constant and variable amplitude loads of different magnitude. A good agreement has been obtained when correlating the magnitude of the roughness and the surface irregularity factor with the stiffness degradation. These results suggest that the changes on the surface roughness measured in strategic zones of components and structures made of CFRP, could be indicative of the level of internal damage due to fatigue loads. The results also suggest that the method is independent of the type of fatigue load that have caused the damage. It makes this measurement technique applicable for a wide range of inspections of composite materials structures, from pressurized tanks with constant amplitude loads, to variable amplitude loaded aeronautical structures like wings and empennages, up to automotive and other industrial applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Debido al creciente aumento del tamaño de los datos en muchos de los actuales sistemas de información, muchos de los algoritmos de recorrido de estas estructuras pierden rendimento para realizar búsquedas en estos. Debido a que la representacion de estos datos en muchos casos se realiza mediante estructuras nodo-vertice (Grafos), en el año 2009 se creó el reto Graph500. Con anterioridad, otros retos como Top500 servían para medir el rendimiento en base a la capacidad de cálculo de los sistemas, mediante tests LINPACK. En caso de Graph500 la medicion se realiza mediante la ejecución de un algoritmo de recorrido en anchura de grafos (BFS en inglés) aplicada a Grafos. El algoritmo BFS es uno de los pilares de otros muchos algoritmos utilizados en grafos como SSSP, shortest path o Betweeness centrality. Una mejora en este ayudaría a la mejora de los otros que lo utilizan. Analisis del Problema El algoritmos BFS utilizado en los sistemas de computación de alto rendimiento (HPC en ingles) es usualmente una version para sistemas distribuidos del algoritmo secuencial original. En esta versión distribuida se inicia la ejecución realizando un particionado del grafo y posteriormente cada uno de los procesadores distribuidos computará una parte y distribuirá sus resultados a los demás sistemas. Debido a que la diferencia de velocidad entre el procesamiento en cada uno de estos nodos y la transfencia de datos por la red de interconexión es muy alta (estando en desventaja la red de interconexion) han sido bastantes las aproximaciones tomadas para reducir la perdida de rendimiento al realizar transferencias. Respecto al particionado inicial del grafo, el enfoque tradicional (llamado 1D-partitioned graph en ingles) consiste en asignar a cada nodo unos vertices fijos que él procesará. Para disminuir el tráfico de datos se propuso otro particionado (2D) en el cual la distribución se haciá en base a las aristas del grafo, en vez de a los vertices. Este particionado reducía el trafico en la red en una proporcion O(NxM) a O(log(N)). Si bien han habido otros enfoques para reducir la transferecnia como: reordemaniento inicial de los vertices para añadir localidad en los nodos, o particionados dinámicos, el enfoque que se va a proponer en este trabajo va a consistir en aplicar técnicas recientes de compression de grandes sistemas de datos como Bases de datos de alto volume o motores de búsqueda en internet para comprimir los datos de las transferencias entre nodos.---ABSTRACT---The Breadth First Search (BFS) algorithm is the foundation and building block of many higher graph-based operations such as spanning trees, shortest paths and betweenness centrality. The importance of this algorithm increases each day due to it is a key requirement for many data structures which are becoming popular nowadays. These data structures turn out to be internally graph structures. When the BFS algorithm is parallelized and the data is distributed into several processors, some research shows a performance limitation introduced by the interconnection network [31]. Hence, improvements on the area of communications may benefit the global performance in this key algorithm. In this work it is presented an alternative compression mechanism. It differs with current existing methods in that it is aware of characteristics of the data which may benefit the compression. Apart from this, we will perform a other test to see how this algorithm (in a dis- tributed scenario) benefits from traditional instruction-based optimizations. Last, we will review the current supercomputing techniques and the related work being done in the area.