19 resultados para Magnetic Resonance imaging(MRI)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mealiness is a sensory attribute that cannot be defined by a single parameter but through a combination of variables (multidimensional structure). Previous studies propose the definition of mealiness as the lack of crispiness, of hardness and of juiciness. Current aims are focused on establishing non destructive tests for mealiness assessment. MultiSliceMultiEcho Magnetic resonance images (MRI, 64*64pixels) have been taken corresponding to a 3ms of Echo time. Small samples of Top Red apples stored 6 months at controlled atmosphere (expected to be non mealy) and 2°C (expected to be mealy) have been used for MRI imaging. Three out of four apples corresponding to the sample maintained at controlled atmosphere did not develop mealiness while three out of four fruits corresponding to the sample stored at 2°C became mealy after 6 month of storage. The minimum T2 values/image obtained for the mealy apples shows to be significantly lower when compared with non mealy apples pointing that a more dis-aggregated structure leads to a quicker loss of signal Also, there is a significant linear correlation (r=-0.76) between the number of pixels with a T2 value below 35ms within a fruit image and the deformation parameter registered during the Magness-Taylor firmness test. Finally, all the T2 images of the mealy apples show a regional variation of contrast which is not shown for non mealy apples. This variation of contrast is similar to the MRI images of water-cored apples indicating that in these cases there is a differential water movement that may precede the internal browning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background DCE@urLAB is a software application for analysis of dynamic contrast-enhanced magnetic resonance imaging data (DCE-MRI). The tool incorporates a friendly graphical user interface (GUI) to interactively select and analyze a region of interest (ROI) within the image set, taking into account the tissue concentration of the contrast agent (CA) and its effect on pixel intensity. Results Pixel-wise model-based quantitative parameters are estimated by fitting DCE-MRI data to several pharmacokinetic models using the Levenberg-Marquardt algorithm (LMA). DCE@urLAB also includes the semi-quantitative parametric and heuristic analysis approaches commonly used in practice. This software application has been programmed in the Interactive Data Language (IDL) and tested both with publicly available simulated data and preclinical studies from tumor-bearing mouse brains. Conclusions A user-friendly solution for applying pharmacokinetic and non-quantitative analysis DCE-MRI in preclinical studies has been implemented and tested. The proposed tool has been specially designed for easy selection of multi-pixel ROIs. A public release of DCE@urLAB, together with the open source code and sample datasets, is available at http://www.die.upm.es/im/archives/DCEurLAB/ webcite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to provide the necessary methods to register and fuse the endo-epicardial signal intensity (SI) maps extracted from contrast-enhanced magnetic resonance imaging (ceMRI) with X-ray coronary ngiograms using an intrinsic registrationbased algorithm to help pre-planning and guidance of catheterization procedures. Fusion of angiograms with SI maps was treated as a 2D-3D pose estimation, where each image point is projected to a Plücker line, and the screw representation for rigid motions is minimized using a gradient descent method. The resultant transformation is applied to the SI map that is then projected and fused on each angiogram. The proposed method was tested in clinical datasets from 6 patients with prior myocardial infarction. The registration procedure is optionally combined with an iterative closest point algorithm (ICP) that aligns the ventricular contours segmented from two ventriculograms.