21 resultados para Low Frequency Electromagnetic Wave


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 6 cylinder servo-hydraulic loading system of CEDEX's track box (250 kN, 50 Hz) has been recently implemented with a new piezoelectric loading system (±20 kN, 300 Hz) allowing the incorporation of low amplitude high frequency dynamic load time histories to the high amplitude low frequency quasi-static load time histories used so far in the CEDEX's track box to assess the inelastic long term behavior of ballast under mixed traffic in conventional and high- speed lines. This presentation will discuss the results obtained in the first long-duration test performed at CEDEX's track box using simultaneously both loading systems, to simulate the pass-by of 6000 freight vehicles (1M of 225 kN axle loads) travelling at a speed of 120 km/h over a line with vertical irregularities corresponding to a medium quality lin3e level. The superstructure of the track tested at full scale consisted of E 60 rails, stiff rail pads (mayor que 450 kN/mm), B90.2 sleepers with USP 0.10 N/mm and a 0.35 m thick ballast layer of ADIF first class. A shear wave velocity of 250 m/s can be assumed for the different layers of the track sub-base. The ballast long-term settlements will be compared with those obtained in a previous long-duration quasi- static test performed in the same track, for the RIVAS [EU co-funded] project, in which no dynamic loads where considered. Also, the results provided by a high diameter cyclic triaxial cell with ballast tested in full size will be commented. Finally, the progress made at CEDEX's Geotechnical Laboratory to reproduce numerically the long term behavior of ballast will be discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detectors designing is a key aspect for the development of the new millimeter wave systems. In this paper two detectors in microstrip technology are presented. They use zero bias Schottky diodes to detect signals from low frequency to 40 GHz. High sensibility, flat frequency response and ultrabroadband are the main features of these designs. They are also cheap and easy to mount because they have been built using microstrip technology. This paper explains most technological questions which must be taken into account to design such detectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo se centra en el estudio de problemas aeroacústicos en los trenes de alta velocidad. Se han considerado dos escenarios en los que las ondas de presión generadas son críticos para el confort de los pasajeros. Uno es el debido a las ondas de presión que genera el tren cuando entra y sale de un túnel, que a su vez producen saltos de presión de baja frecuencia en el tren (cuando se cruzan con él) y en los alrededores del túnel cuando alcanzan la salida. Se estudia este fenómeno, y se propone un sistema aeroelástico basado en el galope transversal para disminuir la energía de estas ondas, y se analiza la energía extraíble de las ondas utilizando cuerpos con diferentes secciones transversales [Sorribes-Palmer and Sanz-Andres, 2013]. La influencia de la geometría de los portales en la energía radiada hacia el exterior de túnel es analizada experimentalmente, prestando especial atención a las boquillas porosas. Las ondas de presión en el interior del túnel se han analizado mediante el método de las características. Se han realizado ensayos experimentales para estimar la energía reflejada hacia el interior del túnel al alcanzar las ondas de presión el portal de salida del túnel. Se ha estudiado la formación e interacción entre el portal del túnel y la onda de choque generada en los túneles de gran longitud y pequeña fricción. Se propone un método para describir de forma aproximada el ruido radiado al exterior. Por otro lado se ha estudiado el ruido de media y alta frecuencia de origen aerodinámico. Se ha estudiado la influencia del desprendimiento de la capa límite sobre el tren. Se propone una metodología basada en una sección de tren característica para predecir rápidamente el nivel de presión de sonido dentro y fuera del tren para todo el rango de frecuencias. Se han realizado medidas experimentales en vía de los espectros de presión sobre la superficie del tren, y de la transmisibilidad de las uniones entre estructura y revestimiento. Los resultados experimentales se han utilizado en los modelos vibroacústicos. El método de la sección del tren característica es especialmente útil a altas frecuencias cuando todo el tren se puede modelar mediante el ensamblaje de diferentes secciones características utilizando el análisis estadístico de la energía. ABSTRACT This work is focused on the study of aeroacoustic problems in high speed trains. We have considered two scenarios in which the pressure waves generated are critical for passengers comfort. The first one is due to the pressure waves generated by a train entering in a tunnel. These waves generate pressure gauges inside the train (when they find each other) and outside of the tunnel portals. This phenomenon has been studied, and an aeroelastic system based on transverse galloping to reduce the energy of these waves is proposed. The maximum extractable energy by using bodies with different cross-section shapes is analyzed. The influence of the portals geometry in the energy radiated outwards the tunnel is analyzed experimentally, with particular attention to the porous exits. The pressure waves inside the tunnel have been analyzed using the method of characteristics. Experimental tests to estimate the energy reflected into the tunnel when the pressure waves reach the tunnel portal have been performed. We have studied the generation and interaction between the tunnel portal and a shock wave generated in long tunnels with small friction. A method to describe in an approximated way the pressure radiated outside the tunnel is proposed. In the second scenario, middle and high frequency noise generated aerodynamically has been studied, including the influence of the detachment of the boundary layer around the train. A method based on a train section to quickly predict the sound pressure level inside and outside the train has been proposed. Experimental test have been performed on board to evaluate the pressure power spectra on the surface of the train, and the transmissibility of the junctions between the structure and trim. These experimental results have been used in the vibroacoustic models. The low frequency pressure waves generated with the train during the tunnel crossing has been identified in the pressure spectrum. The train characteristic section method is especially useful at high frequencies, when the whole train can be modeled by assembling different sections using the statistical energy analysis. The sound pressure level inside the train is evaluated inside and outside the tunnel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, various turbulent solutions of the two-dimensional (2D) and three-dimensional compressible Reynolds averaged Navier?Stokes equations are analyzed using global stability theory. This analysis is motivated by the onset of flow unsteadiness (Hopf bifurcation) for transonic buffet conditions where moderately high Reynolds numbers and compressible effects must be considered. The buffet phenomenon involves a complex interaction between the separated flow and a shock wave. The efficient numerical methodology presented in this paper predicts the critical parameters, namely, the angle of attack and Mach and Reynolds numbers beyond which the onset of flow unsteadiness appears. The geometry, a NACA0012 profile, and flow parameters selected reproduce situations of practical interest for aeronautical applications. The numerical computation is performed in three steps. First, a steady baseflow solution is obtained; second, the Jacobian matrix for the RANS equations based on a finite volume discretization is computed; and finally, the generalized eigenvalue problem is derived when the baseflow is linearly perturbed. The methodology is validated predicting the 2D Hopf bifurcation for a circular cylinder under laminar flow condition. This benchmark shows good agreement with the previous published computations and experimental data. In the transonic buffet case, the baseflow is computed using the Spalart?Allmaras turbulence model and represents a mean flow where the high frequency content and length scales of the order of the shear-layer thickness have been averaged. The lower frequency content is assumed to be decoupled from the high frequencies, thus allowing a stability analysis to be performed on the low frequency range. In addition, results of the corresponding adjoint problem and the sensitivity map are provided for the first time for the buffet problem. Finally, an extruded three-dimensional geometry of the NACA0012 airfoil, where all velocity components are considered, was also analyzed as a Triglobal stability case, and the outcoming results were compared to the previous 2D limited model, confirming that the buffet onset is well detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The three-dimensional wall-bounded open cavity may be considered as a simplified geometry found in industrial applications such as leading gear or slotted flats on the airplane. Understanding the three-dimensional complex flow structure that surrounds this particular geometry is therefore of major industrial interest. At the light of the remarkable former investigations in this kind of flows, enough evidences suggest that the lateral walls have a great influence on the flow features and hence on their instability modes. Nevertheless, even though there is a large body of literature on cavity flows, most of them are based on the assumption that the flow is two-dimensional and spanwise-periodic. The flow over realistic open cavity should be considered. This thesis presents an investigation of three-dimensional wall-bounded open cavity with geometric ratio 6:2:1. To this aim, three-dimensional Direct Numerical Simulation (DNS) and global linear instability have been performed. Linear instability analysis reveals that the onset of the first instability in this open cavity is around Recr 1080. The three-dimensional shear layer mode with a complex structure is shown to be the most unstable mode. I t is noteworthy that the flow pattern of this high-frequency shear layer mode is similar to the observed unstable oscillations in supercritical unstable case. DNS of the cavity flow carried out at different Reynolds number from steady state until a nonlinear saturated state is obtained. The comparison of time histories of kinetic energy presents a clearly dominant energetic mode which shifts between low-frequency and highfrequency oscillation. A complete flow patterns from subcritical cases to supercritical case has been put in evidence. The flow structure at the supercritical case Re=1100 resembles typical wake-shedding instability oscillations with a lateral motion existed in the subcritical cases. Also, This flow pattern is similar to the observations in experiments. In order to validate the linear instability analysis results, the topology of the composite flow fields reconstructed by linear superposition of a three-dimensional base flow and its leading three-dimensional global eigenmodes has been studied. The instantaneous wall streamlines of those composited flows display distinguish influence region of each eigenmode. Attention has been focused on the leading high-frequency shear layer mode; the composite flow fields have been fully recognized with respect to the downstream wave shedding. The three-dimensional shear layer mode is shown to give rise to a typical wake-shedding instability with a lateral motions occurring downstream which is in good agreement with the experiment results. Moreover, the spanwise-periodic, open cavity with the same length to depth ratio has been also studied. The most unstable linear mode is different from the real three-dimensional cavity flow, because of the existence of the side walls. Structure sensitivity of the unstable global mode is analyzed in the flow control context. The adjoint-based sensitivity analysis has been employed to localized the receptivity region, where the flow is more sensible to momentum forcing and mass injection. Because of the non-normality of the linearized Navier-Stokes equations, the direct and adjoint field has a large spatial separation. The strongest sensitivity region is locate in the upstream lip of the three-dimensional cavity. This numerical finding is in agreement with experimental observations. Finally, a prototype of passive flow control strategy is applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La perspectiva del arquitecto en calidad ambiental, y salud en un contexto sostenible, se amplía al considerar las radiaciones electromagnéticas no ionizantes en el diseño arquitectónico. En ese sentido, además del confort higrotérmico, acústico, lumínico y de la calidad del aire, se podría considerar el confort electromagnético de un lugar. Dado que existe gran controversia en cuales han de ser los límites de exposición a radiaciones electromagnéticas no ionizantes, establezco como punto de referencia los valores límite más restrictivos, que son los recomendados por la norma SBM-2008, desarrollada por el Institut für Baubiologie & Oekologie Neubeuern (IBN)1. Se plantean como hipótesis que podemos modificar el entorno electromagnético con materiales de construcción y geometría; y que determinados trazados geométricos tienen la capacidad de reducir el impacto de los campos electromagnéticos sobre los organismos vivos. El objetivo consiste en demostrar experimentalmente que podemos trabajar sobre la calidad ambiental electromagnética de un espacio, a través de la elección de materiales de construcción y trazados geométricos, intentando demostrar que existe una relación causa - efecto entre ambos. La metodología plantea tres aproximaciones experimentales, cada una con un tipo de radiación electromagnética, pues se pretende abarcar las situaciones que comúnmente se pueden presentar en un entorno habitado, ya sea urbano o rural. La primera aproximación trata sobre las alteraciones del campo geomagnético natural (nT / m) provocadas por los materiales de construcción. Utilizo el geomagnetómetro BPM 2010, para realizar un ensayo con cuatro tipos de materiales de distinta procedencia: origen vegetal muy poco procesado (corcho aglomerado negro) y más procesado (OSB), origen derivado del petróleo (tablero rígido de poliuretano) y de origen mineral metálico (chapa minionda). De la lectura de los datos se observa relación causa-efecto entre los materiales de construcción estudiados y las modificaciones que pueden ejercer sobre el campo magnético de un lugar. A continuación se estudia el entorno de radiación electromagnética artificial a baja frecuencia (3 Hz a 3 kHz) y a alta frecuencia, (800 MHz a 10 GHz) en vivienda y en oficina utilizando unas geometrías concretas: las tarjetas de corrección de radiaciones. Estas tarjetas se ubican en paramentos verticales y horizontales de un espacio sometido a radiación propia de un entorno urbano. Se concluye que en una habitación inciden múltiples variables simultáneas muy difíciles de trabajar por separado y que aparentemente no se pueden identificar cambios significativos en las mediciones con y sin las tarjetas de corrección de radiaciones. A continuación estudio el entorno de radiación electromagnética artificial a baja frecuencia asociada a la red de distribución eléctrica. Para poder ver cómo este entorno electromagnético lo podemos modificar, utilizo las tarjetas de corrección de radiaciones ubicadas en relación directa con organismos vivos, por un lado germinados de semillas de haba mungo sometidas a campos electromagnéticos complejos a alta y baja frecuencia, propios de una oficina; y por otro lado germinados de semillas de haba mungo, sometidas a campos electromagnéticos puros a 50 Hz, sin influencias de radiación a alta frecuencia. Se concluye que se observa relación causa - efecto entre los trazados geométricos estudiados y su capacidad para reducir el impacto de los campos electromagnéticos a altas y bajas frecuencias sobre las semillas de haba mungo. También utilizo las tarjetas de corrección de radiaciones en un ensayo normalizado en el laboratorio de bioelectromagnetismo del Hospital Universitario Ramón y Cajal, con células de neuroblastoma humano. Se concluye que se observa relación causa - efecto entre los trazados geométricos estudiados y su capacidad para reducir el impacto de los campos electromagnéticos de 50 Hz Y 100 μT sobre células de neuroblastoma humano y además disminuyen la velocidad de proliferación celular respecto del grupo de células de control. Finalmente se estudia el entorno de radiación electromagnética artificial a alta frecuencia, asociado a comunicaciones inalámbricas. Para ello realizo simulaciones con el software CST Studio, sobre las tarjetas de corrección de radiaciones a alta frecuencia. A la luz de los datos se observa relación causa - efecto entre el trazado geométrico estudiado y su capacidad para reducir radiaciones electromagnéticas de alta frecuencia. Se comprueba además que, las tarjetas de corrección de radiaciones disminuyen la intensidad de la radiación acercándose a los límites de exposición establecidos por el instituto de la biología de la construcción alemán, que podrían estar señalando los estándares de biocompatibilidad. ABSTRACT The perspective of the architect in environmental quality, and health in a sustainable context is extended to consider non-ionizing electromagnetic radiation in architectural design. In that sense, besides the hygrothermal, acoustic, lighting and air quality comfort, the electromagnetic comfort of an indoor space could be considered. There is still great controversy about which should be the limits of exposure to nonionizing electromagnetic radiation, as a benchmark, the more restrictive limits are considered, by the SBM- 2008 standard, developed by the Institut für Baubiologie & Oekologie Neubeuern (IBN). The hypotheses that arise are the following: the electromagnetic environment can be modified by using certain construction materials and geometry; and certain geometric design have the ability to reduce the impact of electromagnetic fields on living organisms. The aim is to demonstrate experimentally that we can work on electromagnetic environmental quality of a indoor space, by using certain construction materials and geometric design, trying to demonstrate a cause - effect relationship between them. The methodology raises three experimental approaches, each with a type of radiation, it is intend to cover situations commonly may occur in an inhabited environment, whether urban or rural. The first approach discusses the alteration of the natural magnetic field (nT / m) caused by the building materials. Geomagnetometre BPM 2010 is used for conducting a test with four types of materials from different sources: vegetable origin less processing (black agglomerate cork) and vegetable origin more processed (OSB), petroleum origin (rigid polyurethane board) and metallic origin (miniwave plate). It is observed across the data information that exist cause-effect relationship between the construction materials studied and the modifications that they can exercise on the magnetic field of a place. Then I study the environment of artificial electromagnetic radiation at low frequency (3 Hz to 3 kHz) and high frequency (800 MHz to 10 GHz) in housing and office, using some specific geometries: correcting radiation cards. These cards are placed in vertical and horizontal surfaces of an indoor space concerned by radiation. I conclude that an indoor space is affected by multiple simultaneous variables difficult to work separately and apparently it is not possible identify significant changes in measurements with and without correcting radiation cards. Then the artificial electromagnetic environment of low-frequency radiation associated with the electricity distribution network is studied. To see how the electromagnetic environment can be changed, correcting radiation cards are placed directly related to living organisms. On one hand, mung bean seeds subject to complex electromagnetic fields at low and high frequency, typical of an office; and on the other hand mung bean seeds, subjected to pure electromagnetic fields at 50 Hz, no influenced by high frequency radiation. It is observed that exist cause-effect relationship between the geometric design and their ability to reduce the impact of electromagnetic fields at high and low frequencies that arrives on on mung bean seeds. The correcting radiation cards were also used in a standard test in the bioelectromagnetics laboratory of Ramón y Cajal University Hospital, on human neuroblastoma cells. It is observed that exist cause-effect relationship between the geometric design and their ability to reduce the impact of electromagnetic fields at 50 Hz and 100 μT on human neuroblastoma cells and also decrease the rate of cell proliferation compared to the group of cells control. Finally the artificial electromagnetic radiation environment at high frequency associated with wireless communications was studied. Simulations with CST Study software were made to determine the behavior of correcting radiation cards in high-frequency. It is observed across the data information that exist causeeffect relationship between the geometric design and the ability to reduce the levels of high-frequency electromagnetic radiation. It also checks that radiation correcting cards decrease the intensity of radiation approaching exposure limits established by Institut für Baubiologie & Oekologie Neubeuern (IBN), which could be signaling biocompatibility standards.