27 resultados para Grid-Connected InvertersInverter
Resumo:
The manufacture of photovoltaic (PV) modules has greatly increased in the past few years. The classical PV module is based on crystalline silicon (e-Si) , nevertheless the so called thinfilm technology is gaining importance each year. In this research paper we present a experimental grid-connected solar plant situated in one of the buildings of the Technical University of Madrid, with two main objectives.
Resumo:
The impedance-based stability-assessment method has turned out to be a very effective tool and its usage is rapidly growing in different applications ranging from the conventional interconnected dc/dc systems to the grid-connected renewable energy systems. The results are sometime given as a certain forbidden region in the complex plane out of which the impedance ratio--known as minor-loop gain--shall stay for ensuring robust stability. This letter discusses the circle-like forbidden region occupying minimum area in the complex plane, defined by applying maximum peak criteria, which is well-known theory in control engineering. The investigation shows that the circle-like forbidden region will ensure robust stability only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem within the interconnected system. Experimental evidence is provided based on a small-scale dc/dc distributed system.
Resumo:
With recent technological developments within the field of power conditioning and the progressive decrease of incentives for PV electricity in grid-connected markets, new operation modes for PV systems should be explored beyond the traditional maximization of PV electri city feed-in. An example can be found in the domestic sector, where the use of modern PV hybrid systems combin ed with efficient electrical appliances and demand side management strategies can significantly enhance the PV value for the user. This paper presents an active demand side management system able to displace the consumer’s load curve in response to local (PV hybrid system, user) and external conditions (external grid). In this way, th e consumer becomes an “active consumer” that can also cooperate with others and the grid, increasing even more the PV value for the electrical system.
Resumo:
Grid connected solar plants are a good opportunity for their use for research as a secondary objective. In countries were feed-in tariffs are still active, it is possible to include in the design of the solar plant elements for its use for research. In the case of the solar plant presented here both objectives are covered. The solar plant of this work is formed by PV modules of three different technologies: Multicrystalline, amorphous and CdTe. In one part of the solar plant, the three technologies are working at the same conditions, not only ambient conditions but also similar voltage and current input to the inverters. Both the commercial and the experimental parts of the solar plant have their own independent inverters with their meters but are finally connected to the same meter to inject. In this work we analyse the results for the first year of operation of the experimental solar plant. Productions of three different technologies in exactly the same conditions are compared and presented. According to the results, all the three technologies have conversion efficiencies dropping when the temperature increases. Amorphous module experiences the lesser reduction, whereas the multicrystalline module suffers the most.
Resumo:
Short-term variability in the power generated by large grid-connected photovoltaic (PV) plants can negatively affect power quality and the network reliability. New grid-codes require combining the PV generator with some form of energy storage technology in order to reduce short-term PV power fluctuation. This paper proposes an effective method in order to calculate, for any PV plant size and maximum allowable ramp-rate, the maximum power and the minimum energy storage requirements alike. The general validity of this method is corroborated with extensive simulation exercises performed with real 5-s one year data of 500 kW inverters at the 38.5 MW Amaraleja (Portugal) PV plant and two other PV plants located in Navarra (Spain), at a distance of more than 660 km from Amaraleja.
Resumo:
In recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent generation and energy storage. However, they pose safety issues in being able to support a local island in case of utility disconnection. Thus, in the event of an unintentional island situation, they should be able to detect the loss of mains and disconnect for self-protection and safety reasons. Most of the anti-islanding schemes are implemented within control of single generation devices, such as dc-ac inverters used with solar electric systems being incompatible with the concept of microgrids due to the variety and multiplicity of sources within the microgrid. In this paper, a passive islanding detection method based on the change of the 5th harmonic voltage magnitude at the point of common coupling between grid-connected and islanded modes of operation is presented. Hardware test results from the application of this approach to a laboratory scale microgrid are shown. The experimental results demonstrate the validity of the proposed method, in meeting the requirements of IEEE 1547 standards.
Resumo:
En la última década la potencia instalada de energía solar fotovoltaica ha crecido una media de un 49% anual y se espera que alcance el 16%del consumo energético mundial en el año 2050. La mayor parte de estas instalaciones se corresponden con sistemas conectados a la red eléctrica y un amplio porcentaje de ellas son instalaciones domésticas o en edificios. En el mercado ya existen diferentes arquitecturas para este tipo de instalaciones, entre las que se encuentras los módulos AC. Un módulo AC consiste en un inversor, también conocido como micro-inversor, que se monta en la parte trasera de un panel o módulo fotovoltaico. Esta tecnología ofrece modularidad, redundancia y la extracción de la máxima potencia de cada panel solar de la instalación. Además, la expansión de esta tecnología posibilitará una reducción de costes asociados a las economías de escala y a la posibilidad de que el propio usuario pueda componer su propio sistema. Sin embargo, el micro-inversor debe ser capaz de proporcionar una ganancia de tensión adecuada para conectar el panel solar directamente a la red, mientras mantiene un rendimiento aceptable en un amplio rango de potencias. Asimismo, los estándares de conexión a red deber ser satisfechos y el tamaño y el tiempo de vida del micro-inversor son factores que han de tenerse siempre en cuenta. En esta tesis se propone un micro-inversor derivado de la topología “forward” controlado en el límite entre los modos de conducción continuo y discontinuo (BCM por sus siglas en inglés). El transformador de la topología propuesta mantiene la misma estructura que en el convertidor “forward” clásico y la utilización de interruptores bidireccionales en el secundario permite la conexión directa del inversor a la red. Asimismo el método de control elegido permite obtener factor de potencia cercano a la unidad con una implementación sencilla. En la tesis se presenta el principio de funcionamiento y los principales aspectos del diseño del micro-inversor propuesto. Con la idea de mantener una solución sencilla y de bajo coste, se ha seleccionado un controlador analógico que está originalmente pensado para controlar un corrector del factor de potencia en el mismo modo de conducción que el micro-inversor “forward”. La tesis presenta las principales modificaciones necesarias, con especial atención a la detección del cruce por cero de la corriente (ZCD por sus siglas en inglés) y la compatibilidad del controlador con la inclusión de un algoritmo de búsqueda del punto de máxima potencia (MPPT por sus siglas en inglés). Los resultados experimentales muestran las limitaciones de la implementación elegida e identifican al transformador como el principal contribuyente a las pérdidas del micro-inversor. El principal objetivo de esta tesis es contribuir a la aplicación de técnicas de control y diseño de sistemas multifase en micro-inversores fotovoltaicos. En esta tesis se van a considerar dos configuraciones multifase diferentes aplicadas al micro-inversor “forward” propuesto. La primera consiste en una variación con conexión paralelo-serie que permite la utilización de transformadores con una relación de vueltas baja, y por tanto bien acoplados, para conseguir una ganancia de tensión adecuada con un mejor rendimiento. Esta configuración emplea el mismo control BCM cuando la potencia extraída del panel solar es máxima. Este método de control implica que la frecuencia de conmutación se incrementa considerablemente cuando la potencia decrece, lo que compromete el rendimiento. Por lo tanto y con la intención de mantener unos bueno niveles de rendimiento ponderado, el micro-inversor funciona en modo de conducción discontinuo (DCM, por sus siglas en inglés) cuando la potencia extraía del panel solar es menor que la máxima. La segunda configuración multifase considerada en esta tesis es la aplicación de la técnica de paralelo con entrelazado. Además se han considerado dos técnicas diferentes para decidir el número de fases activas: dependiendo de la potencia continua extraída del panel solar y dependiendo de la potencia instantánea demandada por el micro-inversor. La aplicación de estas técnicas es interesante en los sistemas fotovoltaicos conectados a la red eléctrica por la posibilidad que brindan de obtener un rendimiento prácticamente plano en un amplio rango de potencia. Las configuraciones con entrelazado se controlan en DCM para evitar la necesidad de un control de corriente, lo que es importante cuando el número de fases es alto. Los núcleos adecuados para todas las configuraciones multifase consideradas se seleccionan usando el producto de áreas. Una vez seleccionados los núcleos se ha realizado un diseño detallado de cada uno de los transformadores. Con la información obtenida de los diseños y los resultados de simulación, se puede analizar el impacto que el número de transformadores utilizados tiene en el tamaño y el rendimiento de las distintas configuraciones. Los resultados de este análisis, presentado en esta tesis, se utilizan posteriormente para comparar las distintas configuraciones. Muchas otras topologías se han presentado en la literatura para abordar los diferentes aspectos a considerar en los micro-inversores, que han sido presentados anteriormente. La mayoría de estas topologías utilizan un transformador de alta frecuencia para solventar el salto de tensión y evitar problemas de seguridad y de puesta a tierra. En cualquier caso, es interesante evaluar si topologías sin aislamiento galvánico son aptas para su utilización como micro-inversores. En esta tesis se presenta una revisión de inversores con capacidad de elevar tensión, que se comparan bajo las mismas especificaciones. El objetivo es proporcionar la información necesaria para valorar si estas topologías son aplicables en los módulos AC. Las principales contribuciones de esta tesis son: • La aplicación del control BCM a un convertidor “forward” para obtener un micro-inversor de una etapa sencillo y de bajo coste. • La modificación de dicho micro-inversor con conexión paralelo-series de transformadores que permite reducir la corriente de los semiconductores y una ganancia de tensión adecuada con transformadores altamente acoplados. • La aplicación de técnicas de entrelazado y decisión de apagado de fases en la puesta en paralelo del micro-inversor “forward”. • El análisis y la comparación del efecto en el tamaño y el rendimiento del incremento del número de transformadores en las diferentes configuraciones multifase. • La eliminación de las medidas y los lazos de control de corriente en las topologías multifase con la utilización del modo de conducción discontinuo y un algoritmo MPPT sin necesidad de medida de corriente. • La recopilación y comparación bajo las mismas especificaciones de topologías inversoras con capacidad de elevar tensión, que pueden ser adecuadas para la utilización como micro-inversores. Esta tesis está estructurada en seis capítulos. El capítulo 1 presenta el marco en que se desarrolla la tesis así como el alcance de la misma. En el capítulo 2 se recopilan las topologías existentes de micro-invesores con aislamiento y aquellas sin aislamiento cuya implementación en un módulo AC es factible. Asimismo se presenta la comparación entre estas topologías bajo las mismas especificaciones. El capítulo 3 se centra en el micro-inversor “forward” que se propone originalmente en esta tesis. La aplicación de las técnicas multifase se aborda en los capítulos 4 y 5, en los que se presentan los análisis en función del número de transformadores. El capítulo está orientado a la propuesta paralelo-serie mientras que la configuración con entrelazado se analiza en el capítulo 5. Por último, en el capítulo 6 se presentan las contribuciones de esta tesis y los trabajos futuros. ABSTRACT In the last decade the photovoltaic (PV) installed power increased with an average growth of 49% per year and it is expected to cover the 16% of the global electricity consumption by 2050. Most of the installed PV power corresponds to grid-connected systems, with a significant percentage of residential installations. In these PV systems, the inverter is essential since it is the responsible of transferring into the grid the extracted power from the PV modules. Several architectures have been proposed for grid-connected residential PV systems, including the AC-module technology. An AC-module consists of an inverter, also known as micro-inverter, which is attached to a PV module. The AC-module technology offers modularity, redundancy and individual MPPT of each module. In addition, the expansion of this technology will enable the possibility of economies of scale of mass market and “plug and play” for the user, thus reducing the overall cost of the installation. However, the micro-inverter must be able to provide the required voltage boost to interface a low voltage PV module to the grid while keeping an acceptable efficiency in a wide power range. Furthermore, the quality standards must be satisfied and size and lifetime of the solutions must be always considered. In this thesis a single-stage forward micro-inverter with boundary mode operation is proposed to address the micro-inverter requirements. The transformer in the proposed topology remains as in the classic forward converter and bidirectional switches in the secondary side allows direct connection to the grid. In addition the selected control strategy allows high power factor current with a simple implementation. The operation of the topology is presented and the main design issues are introduced. With the intention to propose a simple and low-cost solution, an analog controller for a PFC operated in boundary mode is utilized. The main necessary modifications are discussed, with the focus on the zero current detection (ZCD) and the compatibility of the controller with a MPPT algorithm. The experimental results show the limitations of the selected analog controller implementation and the transformer is identified as a main losses contributor. The main objective of this thesis is to contribute in the application of control and design multiphase techniques to the PV micro-inverters. Two different multiphase configurations have been applied to the forward micro-inverter proposed in this thesis. The first one consists of a parallel-series connected variation which enables the use of low turns ratio, i.e. well coupled, transformers to achieve a proper voltage boost with an improved performance. This multiphase configuration implements BCM control at maximum load however. With this control method the switching frequency increases significantly for light load operation, thus jeopardizing the efficiency. Therefore, in order to keep acceptable weighted efficiency levels, DCM operation is selected for low power conditions. The second multiphase variation considered in this thesis is the interleaved configuration with two different phase shedding techniques: depending on the DC power extracted from the PV panel, and depending on the demanded instantaneous power. The application of interleaving techniques is interesting in PV grid-connected inverters for the possibility of flat efficiency behavior in a wide power range. The interleaved variations of the proposed forward micro-inverter are operated in DCM to avoid the current loop, which is important when the number of phases is large. The adequate transformer cores for all the multiphase configurations are selected according to the area product parameter and a detailed design of each required transformer is developed. With this information and simulation results, the impact in size and efficiency of the number of transformer used can be assessed. The considered multiphase topologies are compared in this thesis according to the results of the introduced analysis. Several other topological solutions have been proposed to solve the mentioned concerns in AC-module application. The most of these solutions use a high frequency transformer to boost the voltage and avoid grounding and safety issues. However, it is of interest to assess if the non-isolated topologies are suitable for AC-module application. In this thesis a review of transformerless step-up inverters is presented. The compiled topologies are compared using a set benchmark to provide the necessary information to assess whether non-isolated topologies are suitable for AC-module application. The main contributions of this thesis are: • The application of the boundary mode control with constant off-time to a forward converter, to obtain a simple and low-cost single-stage forward micro-inverter. • A modification of the forward micro-inverter with primary-parallel secondary-series connected transformers to reduce the current stress and improve the voltage gain with highly coupled transformers. •The application of the interleaved configuration with different phase shedding strategies to the proposed forward micro-inverter. • An analysis and comparison of the influence in size and efficiency of increasing the number of transformers in the parallel-series and interleaved multiphase configurations. • Elimination of the current loop and current measurements in the multiphase topologies by adopting DCM operation and a current sensorless MPPT. • A compilation and comparison with the same specifications of suitable non-isolated step-up inverters. This thesis is organized in six chapters. In Chapter 1 the background of single-phase PV-connected systems is discussed and the scope of the thesis is defined. Chapter 2 compiles the existing solutions for isolated micro-inverters and transformerless step-up inverters suitable for AC-module application. In addition, the most convenient non-isolated inverters are compared using a defined benchmark. Chapter 3 focuses on the originally proposed single-stage forward micro-inverter. The application of multiphase techniques is addressed in Chapter 4 and Chapter 5, and the impact in different parameters of increasing the number of phases is analyzed. In Chapter 4 an original primary-parallel secondary-series variation of the forward micro-inverter is presented, while Chapter 5 focuses on the application of the interleaved configuration. Finally, Chapter 6 discusses the contributions of the thesis and the future work.
Resumo:
The growth of wind power as an electric energy source is profitable from an environmental point of view and improves the energetic independence of countries with little fossil fuel resources. However, the wind resource randomness poses a great challenge in the management of electric grids. This study raises the possibility of using hydrogen as a mean to damp the variability of the wind resource. Thus, it is proposed the use of all the energy produced by a typical wind farm for hydrogen generation, that will in turn be used after for suitable generation of electric energy according to the operation rules in a liberalized electric market.
Resumo:
Isolated electrical systems lack electrical interconnection to other networks and are usually placed in geographically isolated areas—mainly islands or locations in developing countries. Until recently, only diesel generators were able to assure a safe and reliable supply in exchange for very high costs for fuel transportation and system operation. Transmission system operators (TSOs) are increasingly seeking to replace traditional energy models based on large groups of conventional generation units with mixed solutions where diesel groups are held as backup generation and important advantages are provided by renewable energy sources. The grid codes determine the technical requirements to be fulfilled by the generators connected in any electrical network, but regulations applied to isolated grids are more demanding. In technical literature it is rather easy to find and compare grid codes for interconnected electrical systems. However, the existing literature is incomplete and sparse regarding isolated grids. This paper aims to review the current state of isolated systems and grid codes applicable to them, specifying points of comparison and defining the guidelines to be followed by the upcoming regulations.
Resumo:
Electrical power systems are changing their traditional structure, which was based on a little number of large generating power plants placed at great distances from loads by new models that tend to split the big production nodes in many smaller ones. The set of small groups which are located close to consumers and provide safe and quality energy is called distributed generation (DG). The proximity of the sources to the loads reduces losses associated with transportation and increases overall system efficiency. DG also favors the inclusion of renewable energy sources in isolated electrical systems or remote microgrids, because they can be installed where the natural resource is located. In both cases, as weak grids unable to get help from other nearby networks, it is essential to ensure appropriate behavior of DG sources to guarantee power system safety and stability. The grid codes sets out the technical requirements to be fulfilled for the sources connected in these electrical networks. In technical literature it is rather easy to find and compare grid codes for interconnected electrical systems. However, the existing literature is incomplete and sparse regarding isolated electrical systems and this happens due to the difficulties inherent in the pursuit of codes. Some countries have developed their own legislation only for their island territory (as Spain or France), others apply the same set of rules as in mainland, another group of island countries have elaborated a complete grid code for all generating sources and some others lack specific regulation. This paper aims to make a complete review of the state of the art in grid codes applicable to isolated systems, setting the comparison between them and defining the guidelines predictably followed by the upcoming regulations in these particular systems.
Resumo:
This paper presents a novel vehicle to vehicle energy exchange market (V2VEE) between electric vehicles (EVs) for decreasing the energy cost to be paid by some users whose EVs must be recharged during the day to fulfil their daily scheduled trips and also reducing the impact of charging on the electric grid. EVs with excess of energy in their batteries can transfer this energy among other EVs which need charge during their daily trips. These second type of owners can buy the energy directly to the electric grid or they can buy the energy from other EV at lower price. An aggregator is responsible for collecting all information among vehicles located in the same area at the same time and make possible this energy transfer.
Resumo:
The search for new energy models arises as a necessity to have a sustainable power supply. The inclusion of distributed generation sources (DG) allows to reduce the cost of facilities, increase the security of the grid or alleviate problems of congestion through the redistribution of power flows. In remote microgrids it is needed in a particular way a safe and reliable supply, which can cover the demand for a low cost; due to this, distributed generation is an alternative that is being widely introduced in these grids. But the remote microgrids are especially weak grids because of their small size, low voltage level, reduced network mesh and distribution lines with a high ratio R/X. This ratio affects the coupling between grid voltages and phase shifts, and stability becomes an issue of greater importance than in interconnected systems. To ensure the appropriate behavior of generation sources inserted in remote microgrids -and, in general, any electrical equipment-, it is essential to have devices for testing and certification. These devices must, not only faithfully reproduce disturbances occurring in remote microgrids, but also to behave against the equipment under test (EUT) as a real weak grid. This also makes the device commercially competitive. To meet these objectives and based on the aforementioned, it has been designed, built and tested a voltage disturbances generator, in order to provide a simple, versatile, full and easily scalable device to manufacturers and laboratories in the sector.