17 resultados para Drilled shaft foundations
Resumo:
This research in Cordoba's mosque tower main objective was to analyze and characterize the foundations and the underlying soil, calculating the stability of the monument as well as the settlement and deformations performed, using traditional calculation methods and also by finite elements, and to determine differences between both, as well as the stability factor of the Minaret Tower. The works done to study the soil, were drill bores and dynamic penetration tests, classification of samples by size, Atterberg limits, physical and chemical analysis, showing the typical geotechnical composition of the Guadalquivir valley: an alluvial material composed by sand, gravels and silt clays. To study the foundations, inclined bore samples were extracted with 10-65º, showing calcarenite stone ashlars and lime concrete alternating with stone and brick masonry.
Resumo:
Current design practices recommend to comply with the capacity protection principle, which pays special attention to ensuring an elastic response of the foundations under ground motion events. However, in cases such as elevated reinforced concrete (RC) pile-cap foundation typologies, this design criterion may lead to conservative designs, with excessively high construction costs. Reinforced concrete elevated pile-cap foundations is a system formed by a group of partially embedded piles connected through an aboveground stayed cap and embedded in soil. In the cases when they are subjected to ground motions, the piles suffer large bending moments that make it difficult to maintain their behavior within the elastic range of deformations. Aiming to make an in-depth analysis of the nonlinear behavior of elevated pile-cap foundations, a cyclic loading test was performed on a concrete 2x3 pile configuration specimen of elevated pile-cap foundation. Two results of this test, the failure mechanism and the ductile behavior, were used for the calibration of a numerical model built in OpenSees framework, by using a pushover analysis. The calibration of the numerical model enabled an in-depth study of the seismic nonlinear response of this kind of foundations. A parametric analysis was carried for this purpose, aiming to study how sensitive RC elevated pile-cap foundations are, when subjected to variations in the diameter of piles, reinforcement ratios, external loads, soil density or multilayer configurations. This analysis provided a set of ductility factors that can be used as a reference for design practices and which correspond to each of the cases analyzed.