19 resultados para Compact fluorescent lamps (CFLs)
Resumo:
A compact 680-GHz waveguide orthomode transducer (OMT) and circular horn combination has been designed, tested, and characterized in a radar transceiver's duplexer. The duplexing capability is implemented by a hybrid waveguide quasi optical solution, combining a linear polarization OMT and an external grating polarizer. Isolation between the OMT's orthogonal ports' flanges was measured with a vector network analyzer to exceed 33 dB over a >10% bandwidth between 630 and 710 GHz. Calibrated Y-factor measurements using a mixer attached to the OMT ports reveal losses through the transmit and receive paths that sum to an average of 4.7 dB of two-way loss over 660-690 GHz. This is consistent with radar sensitivity measurements comparing the new OMT/horn with a quasi-optical wire grid beam splitter. Moreover, the radar performance assessment validates the OMT as a suitable compact substitute of the wire grid for the JPL's short-range 680-GHz imaging radar.
Resumo:
Esta tesis considera dos tipos de aplicaciones del diseño óptico: óptica formadora de imagen por un lado, y óptica anidólica (nonimaging) o no formadora de imagen, por otro. Las ópticas formadoras de imagen tienen como objetivo la obtención de imágenes de puntos del objeto en el plano de la imagen. Por su parte, la óptica anidólica, surgida del desarrollo de aplicaciones de concentración e iluminación, se centra en la transferencia de energía en forma de luz de forma eficiente. En general, son preferibles los diseños ópticos que den como resultado sistemas compactos, para ambos tipos de ópticas (formadora de imagen y anidólica). En el caso de los sistemas anidólicos, una óptica compacta permite tener costes de producción reducidos. Hay dos razones: (1) una óptica compacta presenta volúmenes reducidos, lo que significa que se necesita menos material para la producción en masa; (2) una óptica compacta es pequeña y ligera, lo que ahorra costes en el transporte. Para los sistemas ópticos de formación de imagen, además de las ventajas anteriores, una óptica compacta aumenta la portabilidad de los dispositivos, que es una gran ventaja en tecnologías de visualización portátiles, tales como cascos de realidad virtual (HMD del inglés Head Mounted Display). Esta tesis se centra por tanto en nuevos enfoques de diseño de sistemas ópticos compactos para aplicaciones tanto de formación de imagen, como anidólicas. Los colimadores son uno de los diseños clásicos dentro la óptica anidólica, y se pueden utilizar en aplicaciones fotovoltaicas y de iluminación. Hay varios enfoques a la hora de diseñar estos colimadores. Los diseños convencionales tienen una relación de aspecto mayor que 0.5. Con el fin de reducir la altura del colimador manteniendo el área de iluminación, esta tesis presenta un diseño de un colimador multicanal. En óptica formadora de imagen, las superficies asféricas y las superficies sin simetría de revolución (o freeform) son de gran utilidad de cara al control de las aberraciones de la imagen y para reducir el número y tamaño de los elementos ópticos. Debido al rápido desarrollo de sistemas de computación digital, los trazados de rayos se pueden realizar de forma rápida y sencilla para evaluar el rendimiento del sistema óptico analizado. Esto ha llevado a los diseños ópticos modernos a ser generados mediante el uso de diferentes técnicas de optimización multi-paramétricas. Estas técnicas requieren un buen diseño inicial como punto de partida para el diseño final, que será obtenido tras un proceso de optimización. Este proceso precisa un método de diseño directo para superficies asféricas y freeform que den como resultado un diseño cercano al óptimo. Un método de diseño basado en ecuaciones diferenciales se presenta en esta tesis para obtener un diseño óptico formado por una superficie freeform y dos superficies asféricas. Esta tesis consta de cinco capítulos. En Capítulo 1, se presentan los conceptos básicos de la óptica formadora de imagen y de la óptica anidólica, y se introducen las técnicas clásicas del diseño de las mismas. El Capítulo 2 describe el diseño de un colimador ultra-compacto. La relación de aspecto ultra-baja de este colimador se logra mediante el uso de una estructura multicanal. Se presentará su procedimiento de diseño, así como un prototipo fabricado y la caracterización del mismo. El Capítulo 3 describe los conceptos principales de la optimización de los sistemas ópticos: función de mérito y método de mínimos cuadrados amortiguados. La importancia de un buen punto de partida se demuestra mediante la presentación de un mismo ejemplo visto a través de diferentes enfoques de diseño. El método de las ecuaciones diferenciales se presenta como una herramienta ideal para obtener un buen punto de partida para la solución final. Además, diferentes técnicas de interpolación y representación de superficies asféricas y freeform se presentan para el procedimiento de optimización. El Capítulo 4 describe la aplicación del método de las ecuaciones diferenciales para un diseño de un sistema óptico de una sola superficie freeform. Algunos conceptos básicos de geometría diferencial son presentados para una mejor comprensión de la derivación de las ecuaciones diferenciales parciales. También se presenta un procedimiento de solución numérica. La condición inicial está elegida como un grado de libertad adicional para controlar la superficie donde se forma la imagen. Basado en este enfoque, un diseño anastigmático se puede obtener fácilmente y se utiliza como punto de partida para un ejemplo de diseño de un HMD con una única superficie reflectante. Después de la optimización, dicho diseño muestra mejor rendimiento. El Capítulo 5 describe el método de las ecuaciones diferenciales ampliado para diseños de dos superficies asféricas. Para diseños ópticos de una superficie, ni la superficie de imagen ni la correspondencia entre puntos del objeto y la imagen pueden ser prescritas. Con esta superficie adicional, la superficie de la imagen se puede prescribir. Esto conduce a un conjunto de tres ecuaciones diferenciales ordinarias implícitas. La solución numérica se puede obtener a través de cualquier software de cálculo numérico. Dicho procedimiento también se explica en este capítulo. Este método de diseño da como resultado una lente anastigmática, que se comparará con una lente aplanática. El diseño anastigmático converge mucho más rápido en la optimización y la solución final muestra un mejor rendimiento. ABSTRACT We will consider optical design from two points of view: imaging optics and nonimaging optics. Imaging optics focuses on the imaging of the points of the object. Nonimaging optics arose from the development of concentrators and illuminators, focuses on the transfer of light energy, and has wide applications in illumination and concentration photovoltaics. In general, compact optical systems are necessary for both imaging and nonimaging designs. For nonimaging optical systems, compact optics use to be important for reducing cost. The reasons are twofold: (1) compact optics is small in volume, which means less material is needed for mass-production; (2) compact optics is small in size and light in weight, which saves cost in transportation. For imaging optical systems, in addition to the above advantages, compact optics increases portability of devices as well, which contributes a lot to wearable display technologies such as Head Mounted Displays (HMD). This thesis presents novel design approaches of compact optical systems for both imaging and nonimaging applications. Collimator is a typical application of nonimaging optics in illumination, and can be used in concentration photovoltaics as well due to the reciprocity of light. There are several approaches for collimator designs. In general, all of these approaches have an aperture diameter to collimator height not greater than 2. In order to reduce the height of the collimator while maintaining the illumination area, a multichannel design is presented in this thesis. In imaging optics, aspheric and freeform surfaces are useful in controlling image aberrations and reducing the number and size of optical elements. Due to the rapid development of digital computing systems, ray tracing can be easily performed to evaluate the performance of optical system. This has led to the modern optical designs created by using different multi-parametric optimization techniques. These techniques require a good initial design to be a starting point so that the final design after optimization procedure can reach the optimum solution. This requires a direct design method for aspheric and freeform surface close to the optimum. A differential equation based design method is presented in this thesis to obtain single freeform and double aspheric surfaces. The thesis comprises of five chapters. In Chapter 1, basic concepts of imaging and nonimaging optics are presented and typical design techniques are introduced. Readers can obtain an understanding for the following chapters. Chapter 2 describes the design of ultra-compact collimator. The ultra-low aspect ratio of this collimator is achieved by using a multichannel structure. Its design procedure is presented together with a prototype and its evaluation. The ultra-compactness of the device has been approved. Chapter 3 describes the main concepts of optimizing optical systems: merit function and Damped Least-Squares method. The importance of a good starting point is demonstrated by presenting an example through different design approaches. The differential equation method is introduced as an ideal tool to obtain a good starting point for the final solution. Additionally, different interpolation and representation techniques for aspheric and freeform surface are presented for optimization procedure. Chapter 4 describes the application of differential equation method in the design of single freeform surface optical system. Basic concepts of differential geometry are presented for understanding the derivation of partial differential equations. A numerical solution procedure is also presented. The initial condition is chosen as an additional freedom to control the image surface. Based on this approach, anastigmatic designs can be readily obtained and is used as starting point for a single reflective surface HMD design example. After optimization, the evaluation shows better MTF. Chapter 5 describes the differential equation method extended to double aspheric surface designs. For single optical surface designs, neither image surface nor the mapping from object to image can be prescribed. With one more surface added, the image surface can be prescribed. This leads to a set of three implicit ordinary differential equations. Numerical solution can be obtained by MATLAB and its procedure is also explained. An anastigmatic lens is derived from this design method and compared with an aplanatic lens. The anastigmatic design converges much faster in optimization and the final solution shows better performance.
Resumo:
La preservación del medio ambiente, el avance en las técnicas para que el impacto de la actividad humana sobre la fauna y flora sea lo menor posible, hacen que se deban monitorizar los diversos indicadores de calidad. El presente estudio viene motivado debido a que actualmente existen sistemas de medida y control en continuo de la calidad de las aguas, al margen de los estudios de laboratorio por toma de muestras, a través de los cuales se obtienen indicadores de calidad. El desarrollo tecnológico en analizadores en continuo para la medida de fósforo, amonio, DBO y otros, hacen que cada vez se consiga un control más exhaustivo de la calidad en tiempo real. Sin embargo, la detección temprana de contaminantes que no deben encontrarse presentes en el agua, hacen que el desarrollo de sensores de detección de estos contaminantes sea de gran utilidad. A este respecto, las técnicas mediante fluorescencia presentan enormes ventajas, ya que no existe contacto directo con la muestra, reduciéndose el desgaste y alargando el tiempo entre mantenimientos, como se ha comprobado en numerosos desarrollos con tecnología láser. Para la producir fluorescencia, tradicionalmente se vienen utilizando en el laboratorio principalmente lámparas de gas y monocromadores. Los nuevos LED de alta potencia en el espectro ultravioleta son una alternativa muy interesante que además puede ser aplicada en los mencionados sistemas de medición en continuo. En este trabajo se realiza un estudio de viabilidad de estos dispositivos como fuentes de excitación para la producción de fluorescencia tomando como contaminantes los hidrocarburos. El funcionamiento en estaciones en continuo hace que se tenga que realizar además ensayos de vida acelerados, así como estudios de modos de trabajo. Al respecto de la fluorescencia producida, se estudia la influencia de factores que pueden afectar a las medidas, tales como la temperatura. El estudio del espectro y su análisis para la identificación del contaminante es otro de los puntos desarrollados en este trabajo. Por último, y dado que la monitorización se realiza en modo continuo, es necesario un sistema de comunicaciones compacto y fiable: en este apartado se analizan los metamateriales como solución tecnológica, ya que se adapta perfectamente a la filosofía de estas estaciones de medición. ABSTRACT Currently the monitoring of quality indicators is a need to preserve the environment and minimize the impact of human activity on the fauna and flora. Currently there are measuring systems and continuous monitoring of water quality, regardless of sampling laboratory studies, through which quality indicators are obtained. Technological development in continuous analyzers for the measurement of phosphorus, ammonia, BOD and others increasingly make a more comprehensive real-time quality control is achieved. However, early detection of contaminants that should not be present in the water, make the development of sensors for detecting these contaminants is very useful. In this regard, fluorescence techniques have huge advantages, since there is no direct contact with the sample, reducing wear and extending the time between maintenance, as has been demonstrated in numerous developments in laser technology. To produce fluoresce, traditionally are being used mainly gas lamps and monochromators at the laboratory. The new high-power LEDs in the ultraviolet spectrum are a very interesting alternative that can also be applied in the above continuous measurement systems. In this paper a viability study of these devices as excitation sources to produce fluorescence using hydrocarbon as contaminants is performed. The stations in continuous operation makes it necessary to also perform accelerated life tests and studies operating modes. In regard to the fluorescence produced, the influence of factors that may affect the measurements, such as temperature is studied. The study of the spectrum and analysis to identify the contaminant is another of the points developed in this work. Finally, since the monitoring is carried out in continuous mode, a compact and reliable communication is necessary: in this section metamaterials as a technological solution is analyzed since it fits perfectly with the philosophy of these measuring stations.
Resumo:
We demonstrate that standard polycarbonate compact disk surfaces can provide unique adhesion to Al films that is both strong enough to permit Al film nanopatterning and weak enough to allow easy nanopatterned Al film detachment using Scotch tape. Transferred Al nanohole arrays on Scotch tape exhibit excellent optical and plasmonic performance.