348 resultados para Sistemas de energía eléctrica
Resumo:
The optimization of power architectures is a complex problem due to the plethora of different ways to connect various system components. This issue has been addressed by developing a methodology to design and optimize power architectures in terms of the most fundamental system features: size, cost and efficiency. The process assumes various simplifications regarding the utilized DC/DC converter models in order to prevent the simulation time to become excessive and, therefore, stability is not considered. The objective of this paper is to present a simplified method to analyze small-signal stability of a system in order to integrate it into the optimization methodology. A black-box modeling approach, applicable to commercial converters with unknown topology and components, is based on frequency response measurements enabling the system small-signal stability assessment. The applicability of passivity-based stability criterion is assessed. The stability margins are stated utilizing a concept of maximum peak criteria derived from the behavior of the impedance-based sensitivity function that provides a single number to state the robustness of the stability of a well-defined minor-loop gain.
Resumo:
La protección radiológica en la rehabilitación de Fukushima
Resumo:
En este artículo se presenta un convertidor CC-CC de una etapa para un amplificador de envolvente de alto rendimiento y alto ancho de banda. Se ha aplicado la técnica de cancelación de rizado a un convertidor reductor síncrono para cancelar el rizado de corriente de salida y así poder disminuir la frecuencia de conmutación sin una reducción en el ancho de banda de gran señal. Se ha modelado el convertidor reductor con red de cancelación de rizado y se detalla el nuevo diseño del mismo, presentándose las ventajas del diseño propuesto así como la validación experimental. La función de transferencia del filtro de salida del convertidor reductor con red de cancelación de rizado se ha modelado y comparado con medidas experimentales, mostrando una buena correspondencia. Se ha validado experimentalmente el diseño propuesto para una frecuencia de conmutación de 4MHz para tensión de salida continua y con una referencia inusoidal. Asimismo, se incluye una validación experimental adicional, donde se compara el rendimiento de esta solución con el del diseño equivalente (mismo ancho de banda y rizado de tensión de salida) del convertidor reductor síncrono convencional.
Resumo:
In this paper a novel bidirectional multiple port dc/dc transformer topology is presented. The novel concept for dc/dc transformer is based on the Series Resonant Converter (SRC)topology operated at its resonant frequency point. This allows for higher switching frequency to be adopted and enables high efficiency/high power density operation. The feasibility of the proposed concept is verified on a 300W, 700 kHz three port prototype with 390V input voltage and 48V and 12V output voltages. A peak overall efficiency of 93% is measured at full load. A very good load and cross regulation characteristic of the converter is observed in the whole load range, from full load to open circuit. The sensitivity analysis of the resonant capacitance is also performed showing very slight deterioration in the converter performances when a resonant capacitor is changed ±30% of its nominal value.
Resumo:
In this paper a novel bidirectional multiple port dc/dc transformer topology is presented. The novel concept for dc/dc transformer is based on the Series Resonant Converter (SRC) topology operated at its resonant frequency point. This allows for higher switching frequency to be adopted and enables high efficiency/high power density operation. The feasibility of the proposed concept is verified on a 300W, 700 kHz three port prototype with 390V input voltage and 48V and 12V output voltages. A peak overall efficiency of 93% is measured at full load. A very good load and cross regulation characteristic of the converter is observed in the whole load range, from full load to open circuit. The sensitivity analysis of the resonant capacitance is also performed showing very slight deterioration in the converter performances when a resonant capacitor is changed ±30% of its nominal value.
Resumo:
In the E2KW Conference we present the research we are following in collaboration with ANESE (Asociación de Empresas de Servicios Energéticos) to check the interaction among barriers that previous studies have identified. We focus our research question in the information problems that include a number of specific problems such as lack of information, asymmetric information and the well-documented principle-agent problem. Asymmetric information problems occur when one party involved in a transaction has more information that the other, which may lead to suboptimal energy decisions. The fact that energy efficiency cannot be observed (ie. it is ?invisible?) further intensifies this asymmetric information barrier.
Resumo:
Leakage power consumption is a com- ponent of the total power consumption in data cen- ters that is not traditionally considered in the set- point temperature of the room. However, the effect of this power component, increased with temperature, can determine the savings associated with the careful management of the cooling system, as well as the re- liability of the system. The work presented in this paper detects the need of addressing leakage power in order to achieve substantial savings in the energy consumption of servers. In particular, our work shows that, by a careful detection and management of two working regions (low and high impact of thermal- dependent leakage), energy consumption of the data- center can be optimized by a reduction of the cooling budget.
Resumo:
High-Performance Computing, Cloud computing and next-generation applications such e-Health or Smart Cities have dramatically increased the computational demand of Data Centers. The huge energy consumption, increasing levels of CO2 and the economic costs of these facilities represent a challenge for industry and researchers alike. Recent research trends propose the usage of holistic optimization techniques to jointly minimize Data Center computational and cooling costs from a multilevel perspective. This paper presents an analysis on the parameters needed to integrate the Data Center in a holistic optimization framework and leverages the usage of Cyber-Physical systems to gather workload, server and environmental data via software techniques and by deploying a non-intrusive Wireless Sensor Net- work (WSN). This solution tackles data sampling, retrieval and storage from a reconfigurable perspective, reducing the amount of data generated for optimization by a 68% without information loss, doubling the lifetime of the WSN nodes and allowing runtime energy minimization techniques in a real scenario.
Resumo:
Reducing the energy consumption for computation and cooling in servers is a major challenge considering the data center energy costs today. To ensure energy-efficient operation of servers in data centers, the relationship among computa- tional power, temperature, leakage, and cooling power needs to be analyzed. By means of an innovative setup that enables monitoring and controlling the computing and cooling power consumption separately on a commercial enterprise server, this paper studies temperature-leakage-energy tradeoffs, obtaining an empirical model for the leakage component. Using this model, we design a controller that continuously seeks and settles at the optimal fan speed to minimize the energy consumption for a given workload. We run a customized dynamic load-synthesis tool to stress the system. Our proposed cooling controller achieves up to 9% energy savings and 30W reduction in peak power in comparison to the default cooling control scheme.
Resumo:
This work is related to the output impedance improvement of a Multiphase Buck converter with Peak Current Mode Control (PCMC) by means of introducing an additional power path that virtually increases the output capacitance during transients. Various solutions that can be employed to improve the dynamic behavior of the converter system exist, but nearly all solutions are developed for a Single Phase Buck converter with Voltage Mode Control (VMC), while in the VRM applications, due to the high currents, the system is usually implemented as a Multiphase Buck Converter with Current Mode Control. The Output Impedance Correction Circuit (OICC) is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. Furthermore, this work extends the OICC concept to a Multiphase Buck Converter system while comparing proposed solution with the system that has n times bigger output capacitor. In addition, the OICC is implemented as a Synchronous Buck Converter with PCMC, thus reducing its influence on the system efficiency
Resumo:
En este artículo se presenta la fuente de alimentación que se está diseñando para alimentar los imanes superconductores del acelerador de partículas europeo XFEL que se está construyendo en Hamburgo, cuyas características le hacen el más avanzado del mundo. Un imán superconductor es una carga muy inductiva que debe ser controlada en corriente y que presenta una caída de tensión muy baja cuando está en modo superconductor. La fuente debe ser capaz de alimentar esta carga con una alta fiabilidad e incorporar varias protecciones que protejan esta carga tan especial.
Resumo:
Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze commercial solar panel performance (i.e., the current-voltage–I-V–curve) at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer’s datasheet.
Resumo:
Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze the performance (i.e., the I - V curve) of a commercial solar panel at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer's datasheet.
Resumo:
Correct modeling of the equivalent circuits regarding solar cell and panels is today an essential tool for power optimization. However, the parameter extraction of those circuits is still a quite difficult task that normally requires both experimental data and calculation procedures, generally not available to the normal user. This paper presents a new analytical method that easily calculates the equivalent circuit parameters from the data that manufacturers usually provide. The analytical approximation is based on a new methodology, since methods developed until now to obtain the aforementioned equivalent circuit parameters from manufacturer's data have always been numerical or heuristic. Results from the present method are as accurate as the ones resulting from other more complex (numerical) existing methods in terms of calculation process and resources.
Resumo:
Short-run forecasting of electricity prices has become necessary for power generation unit schedule, since it is the basis of every profit maximization strategy. In this article a new and very easy method to compute accurate forecasts for electricity prices using mixed models is proposed. The main idea is to develop an efficient tool for one-step-ahead forecasting in the future, combining several prediction methods for which forecasting performance has been checked and compared for a span of several years. Also as a novelty, the 24 hourly time series has been modelled separately, instead of the complete time series of the prices. This allows one to take advantage of the homogeneity of these 24 time series. The purpose of this paper is to select the model that leads to smaller prediction errors and to obtain the appropriate length of time to use for forecasting. These results have been obtained by means of a computational experiment. A mixed model which combines the advantages of the two new models discussed is proposed. Some numerical results for the Spanish market are shown, but this new methodology can be applied to other electricity markets as well