37 resultados para masonry walls


Relevância:

80.00% 80.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The effect of infill walls on the behaviour of frames is widely recognized, and, for several decades now, has been the subject of numerous experimental investigations. However, the analytical modeling of infilled panels and frames under in-plane loading is difficult and generally unreliable. From the point of view of the simulation technique the models may be divided into micromodels and simplified (or macro-) models. Based on the equivalent strut approach (simplified model), in this paper a damage model is proposed for the characterization of masonry walls submitted to lateral cyclic loads. The model, developed along the lines of the Continuum Damage Mechanics, have the advantages of including explicitly the coupling between damage and mechanical behaviour and so is consistent with the definition of damage as a phenomenon with mechanical consequences.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper analyzed the building techniques based in the use of rammed earth in the Late Medieval fortifications in the province of Soria, Spain. The manorial castles of Serón de Nágima and Yanguas were built completely with rammed earth. However, these techinques are different. Through the study of the constructive signals, we can reconstruct the constructive process and made an hypothesis of the auxiliary scaffolding necessary for the construction. After, other four cases in which there is presence of rammed earth are described: Ágreda, Arcos de Jalón, Caracena and the tower of Martín González or castle of La Raya (the Border). Rammed earth is used in some secondary architectural elements and also as a filling of the masonry walls, but somtimes there are ancient rammed earth walls overlaid with stone masonry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La envolvente de la edificación es la responsable de equilibrar el intercambio energético entre el interior y el exterior, por lo tanto cualquier actuación encaminada a la reducción del consumo energético ha de establecer, como uno de sus objetivos prioritarios, la mejora del comportamiento de la misma. Las edificaciones anteriores a 1940 constituyen la mayor parte de las existentes en áreas rurales y centros urbanos. En ellas, la repercusión de la fachada sobre las transmitancias globales pone de manifiesto la necesidad de intervención. Sin embargo, su elevada inercia térmica y los importantes saltos térmicos característicos de gran parte de España plantean la importancia de que aquélla se efectúe por el exterior. A tal respecto, la falta de disponibilidad de espesor suficiente para implantar sistemas tipo SATE deriva en que, frecuentemente, la única solución viable sea la de aislar por el interior perdiendo con ello la capacidad de acumulación térmica del muro y con el asociado riesgo de condensaciones. La amplia tradición en el empleo de revestimientos, especialmente en base de cal, permiten que éstos sean utilizados no sólo como elemento estético o de protección de la obra de fábrica antigua sino también para la mejora del comportamiento térmico del soporte, si se aprovecha el mecanismo de transmisión térmica por radiación. Éste es el objetivo de la presente Tesis Doctoral en la que se estudia la modificación de las propiedades radiantes de los morteros de revestimiento para la mejora de la eficiencia energética de las construcciones históricas, principalmente las constituidas por muros monolíticos, aunque podría ser de aplicación a otro tipo de construcciones compuestas por diversas capas. Como punto de partida, se estudió y revisó la documentación disponible sobre las investigaciones de las tres áreas científico-tecnológicas que convergen en la Tesis Doctoral: rehabilitación, material y comportamiento térmico, a partir de lo cual se comprobó la inexistencia de estudios similares al objeto de la presente Tesis Doctoral. Complementariamente, se analizaron los revestimientos en lo concerniente a los materiales que los constituyen, la composición de las mezclas y características de cada una de las capas así como al enfoque que, desde el punto de vista térmico, se estimaba más adecuado para la obtención de los objetivos propuestos. Basándonos en dichos análisis, se preseleccionaron ochenta materiales que fueron ensayados en términos de reflectancia y emisividad para elegir cuatro con los que se continuó la investigación. Éstos, junto con la cal elegida para la investigación y el árido marmóreo característico de la última capa de revestimiento, fueron caracterizados térmicamente, de forma pormenorizada, así como química y físicamente. Los fundamentos teóricos y los estudios preliminares desarrollados con distintos materiales, en estado fresco y endurecido, fueron empleados en la dosificación de componentes de las mezclas, en dos proporciones distintas, para el estudio del efecto del agregado. Éstas se ensayaron en estado fresco, para comprobar su adecuación de puesta en obra y prever su VI adherencia al soporte, así como en estado endurecido a 28 y 90 días de curado, para conocer las propiedades que permitieran prever su compatibilidad con aquél y estimar el alcance de la reducción de transferencias térmicas lograda. Además, se estudiaron las características generales de las mezclas que sirvieron para establecer correlaciones entre distintas propiedades y entender los resultados mecánicos, físicos (comportamiento frente al agua) y energéticos. Del estudio conjunto de las distintas propiedades analizadas se propusieron dos mezclas, una blanca y otra coloreada, cuyas características permiten garantizar la compatibilidad con la obra de fábrica antigua, desde el punto de vista físico y mecánico, y preservar la autenticidad de los revestimientos, en cuanto a la técnica de aplicación tradicional en sistemas multicapa. El comportamiento térmico de las mismas, sobre una obra de fábrica de 40 cm de espesor, se estimó, en estado estacionario y pseudo-transitorio, demostrándose reducciones del flujo térmico entre 16-48%, en condiciones de verano, y entre el 6-11%, en invierno, en función de la coloración y de la rugosidad de la superficie, en comparación con el empleo de la mezcla tradicional. Por lo que, se constata la viabilidad de los materiales compuestos propuestos y su adecuación al objetivo de la investigación. VII ABSTRACT The envelope is responsible for balancing the energy exchange between the inside and outside in buildings. For this reason, any action aimed at reducing energy consumption must establish, as one of its key priorities, its improvement. In rural areas and urban centers, most of the constructions were built before 1940. In them, the impact of the façade on the global transmittance highlights the need for intervention. However, its high thermal inertia and fluctuation of temperatures in the majority of Spain bring up that it should be placed outside the insulation. In this regard, the lack of availability of enough thickness to implement systems such as ETICS results in that often the only viable solution is to isolate the interior, losing thereby the wall’s heat storage capacity with the associated risk of condensation. The tradition in the use of renders, especially lime-based, allows us to use them not only as an aesthetic element or to protect the ancient masonry, but also for improved thermal performance of the support by taking advantage of the heat transfer mechanism by radiation. This is the aim of this Doctoral Thesis in which the modification of the radiative properties of lime mortars for renders to improve the energy efficiency of historic buildings, mainly composed of monolithic walls, is studied, although it could be applied to other structures composed of several layers. As a starting point, the available literature in the three scientific-technological areas that converge at the Doctoral Thesis: rehabilitation, material and thermal behaviour, was reviewed, and confirmed the absence of researches similar to this Doctoral Thesis. Additionally, the renders were studied with regard to the materials that constitute them, the composition of the mixtures and the characteristics of each layer, as well as to the approach which, from a thermal point of view, was deemed the most suitable for achieving the objectives sets. Based on thre aforementioned analysis, eighty materials tested in terms of reflectance and emissivity were pre-selected, to choose four with which the research was continued. Common marble sand, used in the last layer of the renders, together with the appointed materials and hydrated lime were characterized thermally, in detail, as well as chemically and physically. The theoretical bases and preliminary studies with different materials, in fresh and hardened state, were used in the dosage of the composition of the mixtures. In order to study their effect they were used in two different proportions, that is, ten mixtures in total. These were tested in their fresh state to evaluate their setting-up suitability and foresee their adhesion to the support, as well as in their hardened state, at 28 and 90 days of curing, to establish the properties which enabled us to anticipate their compatibility with the old masonry walls and estimate the scope of the reduction of heat transfers achieved. In addition, the general characteristics of the mixtures used to establish correlations and to understand the mechanical, physical and energy results were studied. Two mixtures, one white and one colored, were proposed as the result of the different properties analysed, whose characteristics allow the guarantee of mechanical and physical compatibility VIII with the old masonry and preserve the authenticity of the renders. The thermal behavior of both, applied on a masonry wall 40 cm thick, was estimated at a steady and pseudo-transient state, with heat flow reductions between 16-48% during summertime and 6-11% during wintertime, depending on the color and surface roughness, compared to the use of the traditional mixture. So, the viability of the proposed composite materials and their fitness to the aim of the research are established.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A diferencia de otros parámetros, el efecto de la existencia de huecos en la aparición y desarrollo de los procesos de fisuración en los paños de fábrica no ha sido considerado por las distintas normativas existentes en la actualidad. En nuestros días se emplea una variada gama de tipologías de elementos de cerramiento para realizar las particiones en las obras de edificación, cada una de ellas con características mecánicas diferentes y distinta metodología de ejecución, siendo de aplicación la misma normativa relativa al cálculo y control de las deformaciones. Tal y como expresamos en el Capitulo 1, en el que se analiza el Estado del Conocimiento, los códigos actuales determinan de forma analítica la flecha probable que se alcanza en los elementos portantes estructurales bajo diferentes condiciones de servicio. Las distintas propuestas que existen respecto para la limitación de la flecha activa, una vez realizado el cálculo de las deformaciones, bien por el método de Branson ó mediante los métodos de integración de curvaturas, no contemplan como parámetro a considerar en la limitación de la flecha activa la existencia y tipología de huecos en un paño de fábrica soportado por la estructura. Sin embargo se intuye y podríamos afirmar que una discontinuidad en cualquier elemento sometido a esfuerzos tiene influencia en el estado tensional del mismo. Si consideramos que, de forma general, los procesos de fisuración se producen al superarse la resistencia a tracción de material constitutivo de la fábrica soportada, es claro que la variación tensional inducida por la existencia de huecos ha de tener cierta influencia en la aparición y desarrollo de los procesos de fisuración en los elementos de partición o de cerramiento de las obras de edificación. En los Capítulos 2 y 3 tras justificar la necesidad de realizar una investigación encaminada a confirmar la relación entre la existencia de huecos en un paño de fábrica y el desarrollo de procesos de fisuración en el mismo, se establece este aspecto como principal Objetivo y se expone la Metodología para su análisis. Hemos definido y justificado en el Capítulo 4 el modelo de cálculo que hemos utilizado para determinar las deformaciones y los procesos de fisuración que se producen en los casos a analizar, en los que se han considerado como variables: los valores de la luz del modelo, el estado de fisuración de los elementos portantes, los efectos de la fluencia y el porcentaje de transmisión de cargas desde el forjado superior al paño de fábrica en estudio. Además se adoptan dos valores de la resistencia a tracción de las fábricas, 0.75MPa y 1.00MPa. La capacidad de representar la fisuración, así como la robustez y fiabilidad ha condicionado y justificado la selección del programa de elementos finitos que se ha utilizado para realizar los cálculos. Aprovechando la posibilidad de reproducir de forma ajustada las características introducidas para cada parámetro, hemos planteado y realizado un análisis paramétricos que considera 360 cálculos iterativos, de cuya exposición es objeto el Capítulo 5, para obtener una serie representativa de resultados sobre los que se realizará el análisis posterior. En el Capítulo 6, de análisis de los resultados, hemos estudiado los valores de deformaciones y estados de fisuración obtenidos para los casos analizados. Hemos determinado la influencia que tiene la presencia de huecos en la aparición de los procesos de fisuración y en las deformaciones que se producen en las diferentes configuraciones estructurales. Las conclusiones que hemos obtenido tras analizar los resultados, incluidas en el Capítulo 7, no dejan lugar a dudas: la presencia, la posición y la tipología de los huecos en los elementos de fábricas soportadas sobre estructuras deformables son factores determinantes respecto de la fisuración y pueden tener influencia en las deformaciones que constituyen la flecha activa del elemento, lo que obliga a plantear una serie de recomendaciones frente al proyecto y frente a la reglamentación técnica. La investigación desarrollada para esta Tesis Doctoral y la metodología aplicada para su desarrollo abre nuevas líneas de estudio, que se esbozan en el Capítulo 8, para el análisis de otros aspectos que no han sido cubiertos por esta investigación a fin de mejorar las limitaciones que deberían establecerse para los Estados Límite de Servicio de Deformaciones correspondientes a las estructuras de edificación. SUMMARY. Unlike other parameters, the effect of the existence of voids in the arising and development of cracking processes in the masonry walls has not been considered by current Codes. Nowadays, a huge variety of enclosure elements types is used to execute partitions in buildings, each one with different mechanical characteristics and different execution methodology, being applied the same rules concerning deflection calculation and control. As indicated in Chapter 1, which analyzes the State of Art, current codes analytically determine the deflection likely to be achieved in structural supporting elements under different service conditions. The different proposals that exist related to live deflection limitation, once performed deformations calculation, either by Branson´s method or considering curvatures integration methods, do not consider in deflection limitation the existence and typology of voids in a masonry wall structured supported. But is sensed and it can be affirmed that a discontinuity in any element under stress influences the stress state of it. If we consider that, in general, cracking processes occur when masonry material tensile strength is exceeded, it is clear that tension variation induced by the existence of voids must have some influence on the emergence and development of cracking processes in enclosure elements of building works. In Chapters 2 and 3, after justifying the need for an investigation to confirm the relationship between the existence of voids in a masonry wall and the development of cracking process in it, is set as the main objective and it is shown the analysis Methodology. We have defined and justified in Chapter 4 the calculation model used to determine the deformation and cracking processes that occur in the cases analyzed, in which were considered as variables: model span values, bearing elements cracking state, creep effects and load transmission percentage from the upper floor to the studied masonry wall. In addition, two masonry tensile strength values 0.75MPa and 1.00MPa have been considered. The cracking consideration ability, robustness and reliability has determined and justified the selection of the finite element program that was used for the calculations. Taking advantage of the ability of accurately consider the characteristics introduced for each parameter, we have performed a parametric analyses that considers 360 iterative calculations, whose results are included in Chapter 5, in order to obtain a representative results set that will be analyzed later. In Chapter 6, results analysis, we studied the obtained values of deformation and cracking configurations for the cases analyzed. We determined the influence of the voids presence in the occurrence of cracking processes and deformations in different structural configurations. The conclusions we have obtained after analyzing the results, included in Chapter 7, leave no doubt: the presence, position and type of holes in masonry elements supported on deformable structures are determinative of cracking and can influence deformations which are the element live deflection, making necessary to raise a number of recommendations related to project and technical regulation. The research undertaken for this Doctoral Thesis and the applied methodology for its development opens up new lines of study, outlined in Chapter 8, for the analysis of other aspects that are not covered by this research, in order to improve the limitations that should be established for Deflections Serviceability Limit States related to building structures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the common pathologies of brickwork masonry structural elements and walls is the cracking associated with the differential settlements and/or excessive deflections of the slabs along the life of the structure. The scarce capacity of the masonry in order to accompany the structural elements that surround it, such as floors, beams or foundations, in their movements makes the brickwork masonry to be an element that frequently presents this kind of problem. This problem is a fracture problem, where the wall is cracked under mixed mode fracture: tensile and shear stresses combination, under static loading. Consequently, it is necessary to advance in the simulation and prediction of brickwork masonry mechanical behaviour under tensile and shear loading. The quasi-brittle behaviour of the brickwork masonry can be studied using the cohesive crack model whose application to other quasibrittle materials like concrete has traditionally provided very satisfactory results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large number of reinforced concrete (RC) frame structures built in earthquake-prone areas such as Haiti are vulnerable to strong ground motions. Structures in developing countries need low-cost seismic retrofit solutions to reduce their vulnerability. This paper investigates the feasibility of using masonry infill walls to reduce deformations and damage caused by strong ground motions in brittle and weak RC frames designed only for gravity loads. A numerical experiment was conducted in which several idealized prototypes representing RC frame structures of school buildings damaged during the Port-au-Prince earthquake (Haiti, 2010) were strengthened by adding elements representing masonry infill walls arranged in different configurations. Each configuration was characterized by the ratio Rm of the area of walls in the direction of the ground motion (in plan) installed in each story to the total floor area. The numerical representations of these idealized RC frame structures with different values of Rm were (hypothetically) subjected to three major earthquakes with peak ground accelerations of approximately 0.5g. The results of the non-linear dynamic response analyses were summarized in tentative relationships between Rm and four parameters commonly used to characterize the seismic response of structures: interstory drift, Park and Ang indexes of damage, and total amount of energy dissipated by the main frame. It was found that Rm=4% is a reasonable minimum design value for seismic retrofitting purposes in cases in which available resources are not sufficient to afford conventional retrofit measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the application of the Integral Masonry System (IMS) to the construction of earthquake resistant houses and its experimental study. To verify the security of this new type of building in seismic areas of the third world two prototypes have been tested, one with adobe and the other with hollow brick. In both cases it’s a two-story 6x6x6 m3 house built to scale 1/2. The tests are carried out at the Laboratory of Antiseismic Structures of the Department of Engineering, Pontifical Catholic University of Peru in Lima, in collaboration with the UPM (Technical University of Madrid). This article shows the design process of the prototypes to test, including the sizing of the reinforcements, the characteristics of the tests and the results obtained. These results show that the IMS with adobe or brick remains stable with no significant cracks faced with a severe earthquake, with an estimated acceleration of 1.8 g. Este artículo presenta una aplicación del Sistema de Albañilería Integral (SAI) a la construcción de viviendas sismorresistentes y su estudio experimental. Para verificar su seguridad para su construcción en zonas sísmicas del tercer mundo se han ensayado dos prototipos, uno con adobe, y otro con ladrillo hueco. Se trata de una vivienda de 6x6x6 m3 y dos plantas que se construyen a escala 1/2. Los ensayos se realizaron en el Laboratorio de Estructuras Antisísmicas del Departamento de Ingeniería de la Pontificia Católica Universidad del Perú (PUCP) de Lima en colaboración con la UPM (Universidad Politécnica de Madrid). Este artículo muestra el proceso de diseño de los prototipos a ensayar, incluido el dimensionado de los refuerzos, las características de los ensayos y los resultados obtenidos. Estos resultados muestran que el SAI con adobe o ladrillo permanece estable sin grietas significativas ante un sismo severo, con una aceleración estimada de 1,8 g.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Raya or frontier between the kingdoms of Castile and Aragón was fortified with a system of castles and walled-cities that were useful during the several conflicts that took place in the Late Medieval Age. The Serón de Nágima castle defended the communication road between the axis of the Jalón river valley, which flows into the Ebro, and Duero valley. Its uniqueness stems from the fact that it is one of the few fortifications in the area where rammed earth is the only building system used. In this paper, the castle building fundaments are exposed mainly focusing on the techniques and building processes developed from the interpretation of the legible constructive signs in its walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early 18th century treatise writer Tomas Vicente Tosca1 includes in his Tratado de la montea y cortes de Canteria [On Masonry Design and Stone Cutting], what is an important documentary source about the lantern of Valencia Cathedral. Tosca writes about this lantern as an example of vaulting over cross arches without the need of buttresses. A geometrical description is followed by an explanation of the structural behavior which manifests his deep understanding of the mechanics of masonry structures. He tries to demonstrate the absence of buttresses supporting his thesis on the appropriate distribution of loads which will reduce the "empujos" [horizontal thrusts] to the point of not requiring more than the thickness of the walls to stand (Tosca [1727] 1992, 227-230). The present article2 assesses T osca' s appreciation studying how loads and the thrusts they generate are transmitted through the different masonry elements that constitute this ciborium. In order to do so, we first present a geometrical analysis and make considerations regarding its materials and construction methods to, subsequently, analyze its stability adopting an equilibrium approach within the theoretical framework of the lower bound limit analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early 18th century treatise writer Tomas Vicente Tosca1 includes in his Tratado de la montea y cortes de Canteria [On Masonry Design and Stone Cutting], what is an important documentary source about the lantern of Valencia Cathedral. Tosca writes about this lantern as an example of vaulting over cross arches without the need of buttresses. A geometrical description is followed by an explanation of the structural behavior which manifests his deep understanding of the mechanics of masonry structures. He tries to demonstrate the absence of buttresses supporting his thesis on the appropriate distribution of loads which will reduce the "empujos" [horizontal thrusts] to the point of not requiring more than the thickness of the walls to stand (Tosca [1727] 1992, 227-230). The present article2 assesses T osca' s appreciation studying how loads and the thrusts they generate are transmitted through the different masonry elements that constitute this ciborium. In order to do so, we first present a geometrical analysis and make considerations regarding its materials and construction methods to, subsequently, analyze its stability adopting an equilibrium approach within the theoretical framework of the lower bound limit analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanofabrication has allowed the development of new concepts such as magnetic logic and race-track memory, both of which are based on the displacement of magnetic domain walls on magnetic nanostripes. One of the issues that has to be solved before devices can meet the market demands is the stochastic behaviour of the domain wall movement in magnetic nanostripes. Here we show that the stochastic nature of the domain wall motion in permalloy nanostripes can be suppressed at very low fields (0.6-2.7 Oe). We also find different field regimes for this stochastic motion that match well with the domain wall propagation modes. The highest pinning probability is found around the precessional mode and, interestingly, it does not depend on the external field in this regime. These results constitute an experimental evidence of the intrinsic nature of the stochastic pinning of domain walls in soft magnetic nanostripes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plate-bandes are straight masonry arches (they are called, also, flat arches or lintel arches). Ideally they have the surfaces of extrados and intrados plane and horizontal. The stones or bricks have radial joints converging usually in one centre. The voussoirs have the form of wedges and in French they are called "claveaux". A plate-bande is, in fact, a lintel made of several stones and the proportions of lintels and plate-bandes are similar. Proportions of plate-bandes, that is the relationship between the thickness t and the span s (t/s)varies, typically between 1/4–1/3 in thick plate-bandes, and is less than 1/20 in the most slender ones. A ratio of circa 1/8 was usual in the 18th Century and follows a simple geometrical rule: the centre form with the intrados an equilateral triangle and the plate-bande should contain an arc of circle. The joints are usually plane, but in some cases present a «rebated» or «stepped» form. Plate-bandes exert an inclined thrust as any masonry arch. This thrust is usually very high and it requires either massive buttresses, or to be built in the middle of thick walls. Master builders and architects have tried since antiquity to calculate the abutment necessary for any arch. A modern architect or engineer will measure the arch thrust in units of force, kN or tons. Traditionally, the thrust has been measured as the size of the buttresses to resist it safely. Old structural rules, then, addressed the design problem establishing a relationship between the span and the depth of the buttress. These were empirical rules, particular for every type of arch or structure in every epoch. Thus, the typical gothic buttress is 1/4 of the vault span, but a Renaissance or baroque barrel vault will need more than 1/3 of the span. A plate-bande would require more than one half of the span; this is precisely the rule cited by the French engineer Gautier, who tried unsuccessfully to justify it by static reasons. They were used, typically, to form the lintels of windows or doors (1-2 m, typically); in Antiquity they were used, also, though rarely, at the gates of city walls or in niches (ca. 2 m, reaching 5.2 m). Plate-bandes may show particular problems: it is not unusual that some sliding of the voussoirs can be observed, particularly in thick plate-bandes. The stepped joints on Fig. 1, left, were used to avoid this problem. There are other «hidden» methods, like iron cramps or the use of stone wedges, etc. In seismic zones these devices were usual. Another problem relates to the deformation; a slight yielding of the abutments, or even the compression of the mortar joints, may lead to some cracking and the descent of the central keystone. Even a tiny descent will convert the original straight line of the intrados in a broken line with a visible «kink» or angle in the middle. Of course, both problems should be avoided. Finally, the wedge form of the voussoirs lead to acute angles in the stones and this can produce partial fractures; this occurs usually at the inferior border of the springers at the abutments. It follows, that to build a successful plate-bande is not an easy matter. Also, the structural study of plate-bandes is far from simple, and mechanics and geometry are related in a particular way. In the present paper we will concentrate on the structural aspects and their constructive consequences, with a historical approach. We will outline the development of structural analysis of plate-bandes from ca. 1700 until today. This brief history has a more than purely academic interest. Different approaches and theories pointed to particular problem, and though the solution given may have been incorrect, the question posed was often pertinent. The paper ends with the application of modern Limit Analysis of Masonry Structures, developed mainly by professor Heyman in the last fifty years. The work aims, also, to give some clues for the actual architect and engineer involved in the analysis or restoration of masonry buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Colegio de Nuestra Señora de la Antigua de Monforte de Lemos (1593-1619) constituye el principal ejemplo del clasicismo herreriano de Galicia. Esta tesis analiza los aspectos técnicos de la construcción de sus bóvedas de cantería, en el marco disciplinar de la Historia de la Construcción. El Colegio contiene varios tipos de bóvedas entre las que destacan su cúpula trasdosada y su escalera monumental. Además, se conservan los documentos notariales históricos que describen las obras y una de las monteas más importantes de Galicia. Las bóvedas han sufrido movimientos y algunas presentan importantes deformaciones, que han suscitado preocupación sobre su estabilidad. El estudio se organiza en tres epígrafes: geometría, construcción y mecánica, tres aspectos estrechamente interrelacionados en este tipo de estructuras. La parte de estudio geométrico parte de un levantamiento en el que se emplea una estación total sin reflectante, una técnica que permite una medición muy precisa de la forma real de las bóvedas. Como complemento se ha recurrido a técnicas de escáner fotográfico. Con los datos de las mediciones se han elaborado los dibujos de las bóvedas, y analizado sus medidas e irregularidades. Se ha incluido un análisis metrológico por métodos inductivos, que ha puesto de manifiesto la unidad utilizada en la construcción. El estudio se completa con la recopilación de las reglas de dimensionamiento que figuran en los tratados, que se comparan con las dimensiones de las bóvedas analizadas. En el estudio constructivo se registran los despieces y la configuración constructiva y se contrastan, por un lado, con las soluciones que aparecen en los principales tratados de los siglos XVI, XVII y XVIII, y por otro, con las descripciones que se encuentran en los documentos históricos del Colegio. Se ha prestado especial atención al estudio de estos documentos, que han permitido conocer algunos aspectos originales del proceso de construcción de estas bóvedas. En una de las paredes del claustro se ha identificado una montea inédita cuyo levantamiento y análisis se incorpora en esta parte. En el estudio mecánico se analiza la estabilidad dentro del marco teórico del Moderno Análisis Límite de Estructuras de Fábricas. La comprensión del comportamiento estructural, unida a la precisión de los levantamientos, ha permitido explicar los movimientos de las fábricas e inferir la geometría original de algunas de las bóvedas, no siempre evidente en los casos de fuertes deformaciones. Los estudios realizados hasta ahora en bóvedas de los siglos XVI y XVII permiten vislumbrar un panorama de soluciones constructivas más rico que el que recogen los tratados históricos. Las nuevas técnicas de medición sin contacto abren nuevas posibilidades para analizar estas estructuras. Los casos estudiados todavía son escasos y se necesita un conjunto más amplio para poder realizar un análisis general. Esta tesis aporta el estudio de uno de esos casos con el fin de contribuir al mejor conocimiento de la construcción en España en los siglos XVI y XVII. ABSTRACT The Colegio de Nuestra Señora de la Antigua (1593-1619), in Monforte de Lemos, Spain, is the best example in Galicia of the classicism influenced by the Monastery of El Escorial and his architect, Juan de Herrera. This thesis analyzes the technical aspects of the construction of its masonry vaults within the discipline of Construction History. The Colegio exhibits various types of vaults, among which the extradosed ashlar dome and the grand staircase are particularly worth mentioning. In addition, the legal documents containing thorough specifications of the work, as well as one of the construction drawings at actual size —one of the best examples in Galicia—, have both been preserved to this date. Some of the vaults have undergone important deformations that have raised concerns about their stability. The study is organized in three sections: geometry, construction, and mechanics, the three clearly interrelated in this type of structures. The geometrical study starts out with a metric survey using a reflectorless total station, a technique that allows a very precise measurement of the actual shape of the vault. This technique was complemented with the use of a photo-based 3D scanner. The resulting measurements were used to draw the vaults, and analyze their dimensions and irregularities. An inductive metrological analysis, which was able to reveal the exact metric unit utilized during the construction, is included in this section. The section is completed with the gathering of the dimensional rules appearing in the various historical treatises, which are compared with the dimensions of the actual vaults. The construction study deals with the quartering of the structure, whose results are compared, on the one hand, with the approaches appearing in the main treatises of the 16th- 18th centuries, and on the other, with the descriptions in the historical documents of the Colegio itself. Special attention has been paid to the study of these documents, which have revealed some original aspects in the construction process of the vaults. In one of the cloister’s walls, a hitherto unheard-of construction drawing at actual size was found. Its survey and analysis is included in this section. The mechanical study analyzes the Colegio's vaults stability within the theoretical frame of the Modern Limit Analysis of Masonry Structures. The interpretation of the structural behavior, coupled with the precision of the surveys, has allowed a deep understanding of the masonry’s movements and the original geometry of some of the vaults —not always evident in the case of strong deformations— has been inferred. The studies dealing with XVI and XVII century vaults conducted up to this date show a landscape of constructive solutions far richer than the one suggested in the historical treatises. The new contactless measuring techniques offer exciting possibilities for the analysis of these structures. The cases studied are still few and more would be needed before a general analysis can be attempted. This thesis constitutes one such additional case and its goal is to improve our understanding of Spanish construction in the 16th-17th centuries.