32 resultados para Electrical energy
Resumo:
Solar Decathlon Europe (SDE) is an international multidisciplinary competition in which 20 universityteams build and operate energy-efficient solar-powered houses. The aim of SDE is not only scientificbut also educational and divulgative, making visitors to understand the problems presented by realengineering applications and architecture. From a research perspective, the energy data gathered dur-ing the competition constitutes a very promising information for the analysis and understanding of thephotovoltaic systems, grid structures, energy balances and energy efficiency of the set of houses. Thisarticle focuses on the electrical energy components of SDE competition, the energy performance of thehouses and the strategies and behaviors followed by the teams. The rules evaluate the houses? electricalenergy self-sufficiency by looking at the electricity autonomy in terms of aggregated electrical energybalance; the temporary generation-consumption profile pattern correlation; and the use of electricityper measurable area. Although the houses are evaluated under the same climatological and consump-tion conditions, production results are very different due to the specific engineering solutions (differentelectrical topologies, presence or absence of batteries, diverse photovoltaic module solutions, etc.)
Resumo:
This paper shows that today’s modelling of electrical noise as coming from noisy resistances is a non sense one contradicting their nature as systems bearing an electrical noise. We present a new model for electrical noise that including Johnson and Nyquist work also agrees with the Quantum Mechanical description of noisy systems done by Callen and Welton, where electrical energy fluctuates and is dissipated with time. By the two currents the Admittance function links in frequency domain with their common voltage, this new model shows the connection Cause-Effect that exists between Fluctuation and Dissipation of energy in time domain. In spite of its radical departure from today’s belief on electrical noise in resistors, this Complex model for electrical noise is obtained from Nyquist result by basic concepts of Circuit Theory and Thermo- dynamics that also apply to capacitors and inductors.
Resumo:
This paper shows a physically cogent model for electrical noise in resistors that has been obtained from Thermodynamical reasons. This new model derived from the works of Johnson and Nyquist also agrees with the Quantum model for noisy systems handled by Callen and Welton in 1951, thus unifying these two Physical viewpoints. This new model is a Complex or 2-D noise model based on an Admittance that considers both Fluctuation and Dissipation of electrical energy to excel the Real or 1-D model in use that only considers Dissipation. By the two orthogonal currents linked with a common voltage noise by an Admittance function, the new model is shown in frequency domain. Its use in time domain allows to see the pitfall behind a paradox of Statistical Mechanics about systems considered as energy-conserving and deterministic on the microscale that are dissipative and unpredictable on the macroscale and also shows how to use properly the Fluctuation-Dissipation Theorem.
Resumo:
Using a new Admittance-based model for electrical noise able to handle Fluctuations and Dissipations of electrical energy, we explain the phase noise of oscillators that use feedback around L-C resonators. We show that Fluctuations produce the Line Broadening of their output spectrum around its mean frequency f0 and that the Pedestal of phase noise far from f0 comes from Dissipations modified by the feedback electronics. The charge noise power 4FkT/R C2/s that disturbs the otherwise periodic fluctuation of charge these oscillators aim to sustain in their L-C-R resonator, is what creates their phase noise proportional to Leeson’s noise figure F and to the charge noise power 4kT/R C2/s of their capacitance C that today’s modelling would consider as the current noise density in A2/Hz of their resistance R. Linked with this (A2/Hz?C2/s) equivalence, R becomes a random series in time of discrete chances to Dissipate energy in Thermal Equilibrium (TE) giving a similar series of discrete Conversions of electrical energy into heat when the resonator is out of TE due to the Signal power it handles. Therefore, phase noise reflects the way oscillators sense thermal exchanges of energy with their environment.
Resumo:
Using a new Admittance-based model for electrical noise able to handle Fluctuations and Dissipations of electrical energy, we explain the phase noise of oscillators that use feedback around L-C resonators. We show that Fluctuations produce the Line Broadening of their output spectrum around its mean frequency f0 and that the Pedestal of phase noise far from f0 comes from Dissipations modified by the feedback electronics. The charge noise power 4FkT/R C2/s that disturbs the otherwise periodic fluctuation of charge these oscillators aim to sustain in their L-C-R resonator, is what creates their phase noise proportional to Leeson’s noise figure F and to the charge noise power 4kT/R C2/s of their capacitance C that today’s modelling would consider as the current noise density in A2/Hz of their resistance R. Linked with this (A2/Hz?C2/s) equivalence, R becomes a random series in time of discrete chances to Dissipate energy in Thermal Equilibrium (TE) giving a similar series of discrete Conversions of electrical energy into heat when the resonator is out of TE due to the Signal power it handles. Therefore, phase noise reflects the way oscillators sense thermal exchanges of energy with their environment
Resumo:
With the rising prices of the retail electricity and the decreasing cost of the PV technology, grid parity with commercial electricity will soon become a reality in Europe. This fact, together with less attractive PV feed-in-tariffs in the near future and incentives to promote self-consumption suggest, that new operation modes for the PV Distributed Generation should be explored; differently from the traditional approach which is only based on maximizing the exported electricity to the grid. The smart metering is experiencing a growth in Europe and the United States but the possibilities of its use are still uncertain, in our system we propose their use to manage the storage and to allow the user to know their electrical power and energy balances. The ADSM has many benefits studied previously but also it has important challenges, in this paper we can observe and ADSM implementation example where we propose a solution to these challenges. In this paper we study the effects of the Active Demand-Side Management (ADSM) and storage systems in the amount of consumed local electrical energy. It has been developed on a prototype of a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead–acid batteries, controllable appliances and smart metering. We carried out simulations for long-time experiments (yearly studies) and real measures for short and mid-time experiments (daily and weekly studies). Results show the relationship between the electricity flows and the storage capacity, which is not linear and becomes an important design criterion.
Resumo:
Este proyecto tiene por objeto el aprovechamiento de calor residual de corrientes de refinería, con bajo nivel térmico y su transformación en energía eléctrica, mediante el ciclo orgánico de Rankine (ORC). Este proceso es similar al ciclo básico de Rankine pero en vez de agua utiliza un fluido orgánico de elevado peso molecular. Este tipo de ciclos se puede utilizar para recuperar calor de fuentes de baja temperatura. Este calor se convierte en trabajo útil que se transforma en electricidad. El principio de trabajo del ciclo orgánico de Rankine es un fluido de trabajo en fase líquida que se bombea a una caldera, donde se evapora y tras pasar a través de una turbina, se condensa de nuevo para iniciar el ciclo. Para la elección de las tecnologías ORC se realizó un estudio de las disponibles en el mercado y se llevó a cabo un análisis de las corrientes con calor residual disponibles en la refinería. Seleccionadas las tecnologías, se realizó un análisis de viabilidad del uso de ciclos ORC para el aprovechamiento de la energía residual en la refinería. Los resultados confirmaron que la aplicación de estos ciclos ORC es rentable, desde el punto de vista económico, técnico y medioambiental. ABSTRACT The objective of the project is the utilization of waste heat from low thermal refinery streams and its subsequent transformation into electrical energy through the application of Organic Rankine Cycle (ORC). This process is similar to Rankine’s basic cycle but instead of water it uses a heavier molecular organic fluid. This type of cycles can be put into use to recover heat from low temperature sources. The heat transforms into useful energy that is converted into electricity. The working principle of the Organic Rankine Cycle is an active fluid in liquid phase which is pumped into a boiler where it evaporates and, after passing through a turbine, it condenses once more restarting the whole cycle over again. Before choosing the ORC technologies, a study was conducted on those products available in the market and an analysis of the waste streams in the refinery was also carried out. Having chosen the technologies, a feasibility study was performed on the use of ORC cycles for the re-utilization of waste energy in the refinery. The results confirmed that the use of ORC cycles is profitable, making it attractive from an economical, technical and environmental point of view.
Resumo:
An electrodynamic bare-tether mission to Jupiter,following the capture of a spacecraft (SC) into an equatorial highly elliptical orbit with perijove at about 1.3 times the Jovian radius, is discussed. Repeated applications of the propellantless Lorentz drag on a spinning tether, at the perijove vicinity, can progressively lower the apojove at constant perijove, for a tour of Galilean moons. Electrical energy is generated and stored as the SC moves from an orbit at 1 : 1 resonance with a moon, down to resonance with the next moon; switching tether current off, stored power is then used as the SC makes a number of flybys of each moon. Radiation dose is calculated throughout the mission,during capture, flybys and moves between moons. The tour mission is limited by both power needs and accumulated dose. The three-stage apojove lowering down to Ganymede, Io, and Europa resonances would total less than 14 weeks, while 4 Ganymede, 20 Europa, and 16 Io flybys would add up to 18 weeks, with the entire mission taking just over seven months and the accumulated radiation dose keeping under 3 Mrad (Si) at 10-mm Al shield thickness.
Resumo:
Este trabajo presenta un estudio de campo sobre confort térmico basado en la concepción adaptativa, para la determinación de las temperaturas y rangos de confort térmico de sujetos habituados a espacios enfriados mecánicamente en viviendas con aire acondicionado (AA) en el clima cálido y húmedo de la ciudad de Maracaibo (Venezuela) y las consecuentes implicaciones energéticas que tiene la satisfacción de esa demanda de confortabilidad en el sector residencial de la ciudad. Para la estimación de la temperatura de confort (Tc) y el rango de temperaturas de confort se aplican diferentes metodologías de análisis estadístico, las cuales son comparadas con las respectivas calculadas con el índice PMV; se analizan también otros aspectos asociados a la confortabilidad térmica, tales como las respuestas en las diferentes escalas de valoración de la confortabilidad, las preferencias, experiencias y expectativas térmicas de los sujetos. Las implicaciones energéticas se determinan en base al consumo de la energía eléctrica residencial debido exclusivamente a la variación de la Tc, entre la obtenida inicialmente en espacios naturalmente ventilados (NV) en Maracaibo (Bravo y Gonzalez 2001a) y la determinada ahora en espacios con AA. Para ello, se utiliza una metodología que es el resultado de la modificación parcial de la propuesta por Yamtraipat et al (2006). Entre los resultados y conclusiones derivadas de este estudio se encuentra que el 57 % de las personas prefieren las mismas condiciones confortables experimentadas en los ambientes con AA y solamente un 30 % prefieren experimentar ambientes ligeramente fríos y ligeramente calientes. Mientras tanto, las estimaciones de la Tc, y el respectivo rango, varían de acuerdo a la metodología empleada. Con la convencional metodología adaptativa, la Tc se estima en 25 °C en un amplio rango de 6 °C, entre 22 °C y 28 °C; mientras que con la metodología denominada “método de los promedios de los intervalos de las sensaciones térmicas” (Gómez-Azpeitia et al, 2007), la misma Tc se estima en 24 °C, en un rango estrecho de 22,5 °C a 25,5 °C y en un rango ampliado de 21 °C a 27 °C (amplitud 6 °C), donde se encuentran las tres cuartas partes de las personas del estudio. Ambas Tc son muy próximas a la temperatura operativa optima de 24,5 °C (rango de 23 °C a 26 °C) establecida por las normas internacionales ISO 7730:1994 y ASHRAE 55:1992 para el verano en climas templados. Sin embargo, la Tc estimada con los valores de PMV resulta ser superior en 1 °C y 2 °C a la Tc estimada con la metodología adaptativa (25 °C) y con el metodo de los promedios de los intervalos (24 °C), respectivamente. Con la metodología aplicada y la muestra del estudio se estima que de haberse registrado una Tbsint igual o próxima a 28 C (equivalente a la Tc en espacios NV en Maracaibo) en todos los espacios medidos (con Tbsint entre 19 C y 29 C), el ahorro total de la energía anual seria de 1.648,1 GWh en un ano respecto al consumo de AA en el año 2007 (2.522,3 GWh en un ano), mientras que el ahorro de energía asumiendo Tbsint de 24 C y de 25 C, resultan en 651,9 GWh en un ano y 425,7 GWh en un ano, respectivamente. Esto significa respectivos consumos adiciones de energía eléctrica equivalentes al 60,4 % y 74,2 %. Finalmente, los hábitos o conductas adoptadas por las personas de este estudio, sumado a las predominantes manifestaciones de confortabilidad en ambientes enfriados mecánicamente, redundan en mayores adaptaciones a condiciones de frio y exigencias de temperaturas de confort más bajas, con su consecuente consumo energético para proveerlas. ABSTRACT This investigation presents a study on thermal comfort following the adaptive approach for the determination of the thermal comfort temperatures and ranges of subjects accustomed to mechanically refrigerated spaces in dwellings with air conditioning (AA) systems in the hot and humid weather of the city of Maracaibo (Venezuela) and the ensuing energy use implications it has on the satisfaction of such demand of comfortability in the residential sector of the city. For the estimation of the comfort temperature (Tc) and the range of comfort temperatures different statistical analysis methodologies were used, which are then compared to the respective values calculated with the PMV index, also discusses other aspects related with thermal comfortability were analyzed, such as the responses on the different scales of perception of thermal comfortability, preferences, experiences and expectations of the analyzed subjects. The energetic implications are determined through the residential energy consumption related exclusively with the variation of the Tc between the originally calculated for naturally ventilated (NV) spaces in Maracaibo (Bravo y Gonzalez 2001a) and the one calculated on the present study with AA. For this, a new methodology was developed by partially modifying the Yamtraipat et al (2006) proposal. Among the results and conclusions of this study are that 57 % of the studied subjects prefer the same comfortable conditions experienced on AA environments and only a 30 % prefer to experience slightly cooler or warmer environments. Also, estimations of the Tc and its respective range vary according to the used methodology. With the conventional adaptive methodology, the Tc is estimated in 25 °C with a wide range of 6 °C, between 22 °C and 28 °C, while using the “thermal sensation intervals averages method” (Gomez-Azpeitia et al, 2007) the Tc is estimated in 24 °C on a narrow range between 22.5 °C and 25.5 °C and a widened range of 21 °C to 27 °C (6 °C in amplitude), a range where . of the studied subjects are located. Both Tc are very close to the optimum operation temperature of 24.5 °C (with a range between 23 °C and 26 °C) established on the ISO 7730:1994 and ASHRAE 55:1992 international norms for the summer on warm climates. However, the estimated Tc with the PMV indexes results to be 1 °C and 2 °C above the Tc estimated with the adaptive methodology (25 °C) and the thermal sensation intervals averages method (24 °C), respectively. With the applied methodology and this study sample, its estimated that if a Tbsint equal or close to 28 °C (equivalent to the Tc in NV spaces in Maracaibo) was registered in all measured spaces (with Tbsint between 19 °C and 29 °C) the total yearly energy savings would be of 1.648,1 GWh in a year with respect to the AA consumption in the year 2007 (2.522.3 GWh in a year), while the energy savings assuming a Tbinst of 24 °C and 25 °C result in 651.9 GWh and 425.7 Gwh in a year, respectively. This means that the respective additional electrical energy consumption amount to 60.4 % and 74.2 %, respectively. Finally, the habits or behaviors adopted by the subjects analyzed on this study, added to the predominant manifestations of comfortability in mechanically refrigerated environments result in greater adaptations to colder conditions and lower thermal comfort temperature demands, with the consequential increase in power consumption to meet them.
Resumo:
Los sistemas de telealimentación han tomado gran importancia en diferentes campos, incluido el de las telecomunicaciones, algunos ejemplos pueden ser: En la red conmutada telefónica junto con la señal de información y llamada existe una alimentación de 48v que se transmite a través de toda la línea de transmisión hasta los terminales. En algunos ferrocarriles eléctricos, se aprovecha la producción de energía eléctrica cuando un tren baja una cuesta y el motor funciona como generador, devolviendo la energía excedente a la propia catenaria por medio de superposición, y siendo esta recuperada en otro lugar y aprovechada por ejemplo por otro tren que requiere energía. Otro uso en ferrocarriles de la telealimentación es la llamada "tecnología del transpondedor magnético", en la que el tren transmite a las balizas una señal en 27MHz además de otras de información propias, que se convierte en energía útil para estas balizas. En este proyecto pretendemos implementar un pequeño ejemplo de sistema de telealimentación trabajando en 5 MHz (RF). Este sistema transforma una señal de CC en una señal de potencia de CA que podría ser, por ejemplo, transmitida a lo largo de una línea de transmisión o radiada por medio de una antena. Después, en el extremo receptor, esta señal RF se transforma finalmente en DC. El objetivo es lograr el mejor rendimiento de conversión de energía, DC a AC y AC a DC. El sistema se divide en dos partes: El inversor, que es la cadena de conversión DC-AC y el rectificador, que es la cadena de conversión AC-DC. Cada parte va a ser calculada, simulada, implementada físicamente y medida aparte. Finalmente el sistema de telealimentación completo se va a medir mediante la interconexión de cada parte por medio de un adaptador o una línea de transmisión. Por último, se mostrarán los resultados obtenidos. ABSTRACT. Remote powering systems have become very important in different fields, including telecommunications, some examples include: In the switched telephone network with the information signal and call there is a 48v supply that is transmitted across the transmission line to the terminals. In some electric railways, the production of electrical energy is used when a train is coming down a hill and the motor acts as a generator, returning the surplus energy to the catenary itself by overlapping, and this being recovered elsewhere and used by other train. Home TV amplifiers that are located in places (storage, remote locations ..) where there is no outlet, remote power allows to carry information and power signal by the same physical medium, for instance a coax. The AC power signal is transformed into DC at the end to feed the amplifier. In medicine, photovoltaic converters and fiber optics can be used as means for feeding devices implanted in patients. Another use of the remote powering systems on railways is the "magnetic transponder technology", in which the station transmits a beacon signal at 27MHz own as well as other information, which is converted into useful energy to these beacons. In this Project we are pretending to implement a little example of remote powering system working in 5 MHz (RF). This system transform DC into an AC-RF power signal which could be, for instance, transmitted throughout a transmission line or radiated by means of an aerial. At the receiving end, this RF signal is then transformed to DC. The objective is to achieve the best power conversion performance, DC to AC and AC to DC. The system is divided in two parts: The inverter, that is the DC-AC conversion chain and the rectifier that is the AC-DC conversion chain. Each part is going to be calculated, simulated, implemented physically and measured apart. Then the complete remote-powering system is to be measured by interconnecting each part by means of a interconnector or a transmission line. Finally, obtained results will be shown.
Resumo:
En 1966, D. B. Leeson publicó el artículo titulado “A simple model of feedback oscillator noise spectrum” en el que, mediante una ecuación obtenida de forma heurística y basada en parámetros conocidos de los osciladores, proponía un modelo para estimar el espectro de potencia que cuantifica el Ruido de Fase de estos osciladores. Este Ruido de Fase pone de manifiesto las fluctuaciones aleatorias que se producen en la fase de la señal de salida de cualquier oscilador de frecuencia f_0. Desde entonces, los adelantos tecnológicos han permitido grandes progresos en cuanto a la medida del Ruido de Fase, llegando a encontrar una estrecha “zona plana”, alrededor de f_0, conocida con el nombre de Ensanchamiento de Línea (EL) que Leeson no llegó a observar y que su modelo empírico no recogía. Paralelamente han ido surgiendo teorías que han tratado de explicar el Ruido de Fase con mayor o menor éxito. En esta Tesis se propone una nueva teoría para explicar el espectro de potencia del Ruido de Fase de un oscilador realimentado y basado en resonador L-C (Inductancia-Capacidad). Al igual que otras teorías, la nuestra también relaciona el Ruido de Fase del oscilador con el ruido térmico del circuito que lo implementa pero, a diferencia de aquellas, nuestra teoría se basa en un Modelo Complejo de ruido eléctrico que considera tanto las Fluctuaciones de energía eléctrica asociadas a la susceptancia capacitiva del resonador como las Disipaciones de energía eléctrica asociadas a su inevitable conductancia G=1⁄R, que dan cuenta del contacto térmico entre el resonador y el entorno térmico que le rodea. En concreto, la nueva teoría que proponemos explica tanto la parte del espectro del Ruido de Fase centrada alrededor de la frecuencia portadora f_0 que hemos llamado EL y su posterior caída proporcional a 〖∆f〗^(-2) al alejarnos de f_0, como la zona plana o pedestal que aparece en el espectro de Ruido de Fase lejos de esa f_0. Además, al saber cuantificar el EL y su origen, podemos explicar con facilidad la aparición de zonas del espectro de Ruido de Fase con caída 〖∆f〗^(-3) cercanas a la portadora y que provienen del denominado “exceso de ruido 1⁄f” de dispositivos de Estado Sólido y del ruido “flicker” de espectro 1⁄f^β (0,8≤β≤1,2) que aparece en dispositivos de vacío como las válvulas termoiónicas. Habiendo mostrado que una parte del Ruido de Fase de osciladores L-C realimentados que hemos denominado Ruido de Fase Térmico, se debe al ruido eléctrico de origen térmico de la electrónica que forma ese oscilador, proponemos en esta Tesis una nueva fuente de Ruido de Fase que hemos llamado Ruido de Fase Técnico, que se añadirá al Térmico y que aparecerá cuando el desfase del lazo a la frecuencia de resonancia f_0 del resonador no sea 0° o múltiplo entero de 360° (Condición Barkhausen de Fase, CBF). En estos casos, la modulación aleatoria de ganancia de lazo que realiza el Control Automático de Amplitud en su lucha contra ruidos que traten de variar la amplitud de la señal oscilante del lazo, producirá a su vez una modulación aleatoria de la frecuencia de tal señal que se observará como más Ruido de Fase añadido al Térmico. Para dar una prueba empírica sobre la existencia de esta nueva fuente de Ruido de Fase, se diseñó y construyó un oscilador en torno a un resonador mecánico “grande” para tener un Ruido de Fase Térmico despreciable a efectos prácticos. En este oscilador se midió su Ruido de Fase Técnico tanto en función del valor del desfase añadido al lazo de realimentación para apartarlo de su CBF, como en función de la perturbación de amplitud inyectada para mostrar sin ambigüedad la aparición de este Ruido de Fase Técnico cuando el lazo tiene este fallo técnico: que no cumple la Condición Barkhausen de Fase a la frecuencia de resonancia f_0 del resonador, por lo que oscila a otra frecuencia. ABSTRACT In 1966, D. B. Leeson published the article titled “A simple model of feedback oscillator noise spectrum” in which, by means of an equation obtained heuristically and based on known parameters of the oscillators, a model was proposed to estimate the power spectrum that quantifies the Phase Noise of these oscillators. This Phase Noise reveals the random fluctuations that are produced in the phase of the output signal from any oscillator of frequencyf_0. Since then, technological advances have allowed significant progress regarding the measurement of Phase Noise. This way, the narrow flat region that has been found around f_(0 ), is known as Line Widening (LW). This region that Leeson could not detect at that time does not appear in his empirical model. After Leeson’s work, different theories have appeared trying to explain the Phase Noise of oscillators. This Thesis proposes a new theory that explains the Phase Noise power spectrum of a feedback oscillator around a resonator L-C (Inductance-Capacity). Like other theories, ours also relates the oscillator Phase Noise to the thermal noise of the feedback circuitry, but departing from them, our theory uses a new, Complex Model for electrical noise that considers both Fluctuations of electrical energy associated with the capacitive susceptance of the resonator and Dissipations of electrical energy associated with its unavoidable conductance G=1/R, which accounts for the thermal contact between the resonator and its surrounding environment (thermal bath). More specifically, the new theory we propose explains both the Phase Noise region of the spectrum centered at the carrier frequency f_0 that we have called LW and shows a region falling as 〖∆f〗^(-2) as we depart from f_0, and the flat zone or pedestal that appears in the Phase Noise spectrum far from f_0. Being able to quantify the LW and its origin, we can easily explain the appearance of Phase Noise spectrum zones with 〖∆f〗^(-3) slope near the carrier that come from the so called “1/f excess noise” in Solid-State devices and “flicker noise” with 1⁄f^β (0,8≤β≤1,2) spectrum that appears in vacuum devices such as thermoionic valves. Having shown that the part of the Phase Noise of L-C oscillators that we have called Thermal Phase Noise is due to the electrical noise of the electronics used in the oscillator, this Thesis can propose a new source of Phase Noise that we have called Technical Phase Noise, which will appear when the loop phase shift to the resonance frequency f_0 is not 0° or an integer multiple of 360° (Barkhausen Phase Condition, BPC). This Phase Noise that will add to the Thermal one, comes from the random modulation of the loop gain carried out by the Amplitude Automatic Control fighting against noises trying to change the amplitude of the oscillating signal in the loop. In this case, the BPC failure gives rise to a random modulation of the frequency of the output signal that will be observed as more Phase Noise added to the Thermal one. To give an empirical proof on the existence of this new source of Phase Noise, an oscillator was designed and constructed around a “big” mechanical resonator whose Thermal Phase Noise is negligible for practical effects. The Technical Phase Noise of this oscillator has been measured with regard to the phase lag added to the feedback loop to separate it from its BPC, and with regard to the amplitude disturbance injected to show without ambiguity the appearance of this Technical Phase Noise that appears when the loop has this technical failure: that it does not fulfill the Barkhausen Phase Condition at f_0, the resonance frequency of the resonator and therefore it is oscillating at a frequency other than f_0.
Resumo:
El proyecto tiene como objeto analizar desde el punto de vista técnico-económico las posibilidades para mejorar el factor de potencia en los consumos auxiliares de la Central térmica Litoral, perteneciente a Endesa Generación. Debido a un cambio normativo, las tarifas de acceso a las redes de transporte y distribución de energía eléctrica aplicarán ahora también a los consumos propios de las empresas productoras de electricidad dentro del ámbito de aplicación de las tarifas de acceso. Como la energía reactiva se facturará en función del factor de potencia se propone para su compensación la instalación de bancos de condensadores para mejorar el mismo y disminuir la penalización. Para el dimensionamiento de los bancos se han utilizado los consumos horarios de los años 2012 y 2013 de tres fronteras: grupos 1 y 2 de 400 kV y los transformadores auxiliares de arranque (OTAAs) de 6 kV , teniendo en cuenta las peculiaridades de una Central de Generación, ya que sólo serán objeto de estudio (a efecto de penalizaciones) las horas en las que el grupo está parado o arrancando. El resultado final muestra la diferencia en cuanto a los periodos de amortización de una instalación con generación y sin generación, siendo esta última más rentable económicamente. ABSTRACT The goal of this project is to analyse the possibilities to better the power factor in the auxiliary consumption of the Thermal Plant Litoral from an economic and technical viewpoint. Due to a normative changes, the access price rates for the transportation and distribution of electrical energy, will also apply now to the electricity productive companies own consumption within the scope of the access rate. Since reactive power is invoiced based on the potency factor, we propose the installation of capacitor banks to improve the aforementioned power factor as compensation so as to reduce sanctions. We have used the time profiles from 2012 and 2013 to dimension the banks, using 3 borders: Group 1 and 2 (400 kV) and the auxiliary starter transformers (OTAA's) of 6kV, taking into account the special characteristics of a Generation Plant , since we will only study the hours that the group was shut down or powering up (since these are what the penalties cover). The final result shows the difference in regards to repayment periods for both generating and nongenerating installation, being the aforesaid the most economically worthwile of the two
Resumo:
En esta tesis se desarrolla una investigación sobre las técnicas de medida de descargas parciales (DP) que se aplican en medidas on-line, en condiciones normales de operación de las instalaciones eléctricas de alta tensión (AT). También se realiza un estudio de técnicas avanzadas de procesado y análisis de las señales medidas, que permiten realizar diagnósticos precisos del estado de los aislamientos eléctricos de AT. Uno de los objetivos fundamentales de la tesis ha sido disponer de un procedimiento eficaz de medida y procesado de las señales de DP, para la realización de medidas on-line tanto de forma itinerante, como mediante monitorización temporal o permanente. La implementación del nuevo procedimiento de medida permite obtener resultados satisfactorios en la detección, identificación y localización de defectos de aislamiento. Se ha dedicado especial interés al desarrollo de un método de clasificación de señales, que permite separar pulsos de ruido y diferentes fuentes de DP, presentes de forma simultánea en las instalaciones de AT. El estudio de la clasificación de señales se ha completado con la aplicación de un método para la detección de manera asistida, de los diferentes grupos de pulsos de ruido y de DP. La aplicación de este método de detección de grupos de pulsos, facilita la labor de los técnicos especialistas a la hora de diagnosticar el estado de los elementos aislantes. Al efecto de verificar de forma práctica las aportaciones de la tesis, se han realizado medidas de DP tanto en laboratorio como en campo. Las medidas experimentales en laboratorio se han efectuado en el Laboratorio de Alta Tensión de la Escuela Técnica Superior de Ingeniería y Diseño Industrial (LAT-UPM), de la Universidad Politécnica de Madrid. Por otro lado, las medidas experimentales en campo se han llevado a cabo en instalaciones de AT propiedad de compañías de transporte y distribución de energía eléctrica. La realización de ensayos de DP en estas instalaciones ha sido posible, gracias a los proyectos de investigación llevados a cabo por el grupo de trabajo del LAT-UPM, con diferentes empresas del sector durante los diez últimos años. ABSTRACT This thesis develops techniques for measuring partial discharges (PD) that are applied in on-line measurements, under normal operating conditions of the high voltage (HV) electrical installations. In addition there are studied advanced techniques for the processing and analysis of the measured signals, that permit precise diagnostics of the state of HV electrical insulation systems. One of the fundamental objectives of the thesis is to make available an effective procedure for measuring and processing PD signals, for making on-line measurements, either in an itinerant way or in temporary or permanent monitoring. The implementation of the new measurement procedure yields satisfactory results in the detection, identification and localization of insulation defects. Special attention has been devoted to the development of a method for classifying signals, that separates noise pulses and various PD sources present simultaneously in the HV installations. The study of the classification of signals has been completed by the application of a method for detecting, in a user assisted manner, the different groups of noise pulses and of PD. The application of this method for detecting groups of pulses facilitates the work of the specialist technicians to diagnose the condition of the insulation elements. To demonstrate the practical value of the thesis, PD measurements were made in laboratory as well as in field installations. The experimental measurements in laboratory were made in the High Voltage Laboratory (LAT-UPM) of the High Technical School of Engineering and Industrial Design, of the Polytechnic University of Madrid. Field measurements were realized in the HV installations of companies providing electrical energy transport and distribution. The realization of PD tests in these facilities was possible thanks to the research projects carried out by the working group of the LAT-UPM during the last ten years, with different companies operating in the sector.
Resumo:
La situación energética actual es insostenible y como consecuencia se plantea un escenario próximo orientado a conseguir un futuro energético sostenible que permita el desarrollo económico y el bienestar social. La situación ambiental actual está afectada directamente por la combustión de combustibles fósiles que en 2013 constituyeron el 81% de la energía primaria utilizada por el ser humano y son la principal fuente antropogénica de gases de efecto invernadero. Los informes del IPCC1, ponen de manifiesto que el cambio climático se ha consolidado durante los últimos años y en la conferencia de la ONU sobre cambio climático de París que se celebrará a finales de 2015, se pretende que los gobiernos suscriban un acuerdo universal para limitar las emisiones de gases de efecto invernadero y evitar que el incremento de la temperatura media global supere los 2°C. Por otra parte, en el interior de las ciudades es especialmente preocupante, por su efecto directo sobre la salud humana, el impacto ambiental producido por las emisiones de NOx que generan el transporte de personas y mercancías. El sector del transporte fue responsable en 2012 del 27,9% del consumo final de energía. Una vez expuesto el escenario energético y ambiental actual, en esta tesis, se analiza la eficiencia de un sistema autónomo fotovoltaico para la carga de baterías de vehículos eléctricos y el uso del mismo con otras cargas, con el objetivo de aprovechar al máximo la energía eléctrica generada y contribuir a la utilización de energía limpia que no produzca impacto ambiental. Como primer paso para el desarrollo de la tesis se hizo un estudio de trabajos previos comenzando por las primeras aplicaciones de la energía fotovoltaica en los vehículos solares para después pasar a trabajos más recientes enfocados al suministro de energía a los vehículos eléctricos. También se hizo este estudio sobre las metodologías de simulación en los sistemas fotovoltaicos y en el modelado de distintos componentes. Posteriormente se eligieron, dentro de la amplia oferta existente en el mercado, los componentes con características técnicas más adecuadas para este tipo de instalaciones y para las necesidades que se pretenden cubrir. A partir de los parámetros técnicos de los componentes elegidos para configurar la instalación autónoma y utilizando modelos contrastados de distintos componentes, se ha desarrollado un modelo de simulación en ordenador del sistema completo con el que se han hecho simulaciones con distintos modos de demanda de energía eléctrica, según los modos de carga disponibles en el vehículo eléctrico para corriente alterna monofásica de 230 V. También se han simulado distintos tamaños del generador fotovoltaico y del sistema de acumulación de energía eléctrica para poder determinar la influencia de estos parámetros en los balances energéticos del sistema. Utilizando recursos propios el doctorando ha realizado la instalación real de un sistema fotovoltaico que incluye sistema de acumulación e inversor en un edificio de su propiedad. Para la realización de la tesis, La Fundación de Fomento e Innovación Industrial (F2I2) ha facilitado al doctorando un dispositivo que permite realizar la alimentación del vehículo eléctrico en modo 2 (este modo emplea un adaptador que incorpora dispositivos de seguridad y se comunica con el vehículo permitiendo ajustar la velocidad de recarga) y que ha sido necesario para los trabajos desarrollados. Se ha utilizado la red eléctrica como sistema de apoyo de la instalación fotovoltaica para permitir la recarga en el modo 2 que requiere más potencia que la proporcionada por el sistema fotovoltaico instalado. Se han analizado mediante simulación distintos regímenes de carga que se han estudiado experimentalmente en la instalación realizada, a la vez que se han hecho ensayos que se han reproducido mediante simulación con los mismos valores de radiación solar y temperatura con objeto de contrastar el modelo. Se han comparado los resultados experimentales con los obtenidos mediante simulación con objeto de caracterizar el comportamiento del sistema de acumulación (energía eléctrica suministrada y tensión de salida en las baterías) y del generador fotovoltaico (energía eléctrica fotovoltaica suministrada). Por último, se ha realizado un estudio económico de la instalación autónoma fotovoltaica ejecutada y simulada. En el mismo se ha planteado la utilización de fondos propios (como realmente se ha llevado a cabo) y la utilización de financiación, para determinar dos posibles escenarios que pudieran ser de utilidad a un propietario de vehículo eléctrico. Se han comparado los resultados obtenidos en los dos escenarios propuestos del estudio económico del sistema, en cuanto a los parámetros de tiempo de retorno de la inversión, valor actual neto de la inversión y tasa interna de retorno de la misma. Las conclusiones técnicas obtenidas, permiten la utilización del sistema con los modos de carga ensayados y otro tipo de cargas que aprovechen la generación eléctrica del sistema. Las baterías ofrecen mejor comportamiento cuando el aporte fotovoltaico está presente, pero no considera adecuado la conexión de cargas elevadas a un sistema de acumulación de gel (plomo-acido) como el que se ha utilizado, debido al comportamiento de este tipo de baterías ante demandas de intensidad de corriente eléctrica elevadas. Por otra parte, el comportamiento de este tipo de baterías con valores de intensidad de corriente eléctrica inferiores a 10 A en ausencia de energía fotovoltaica, con el objetivo de utilizar la generación de energía eléctrica diaria acumulada en el sistema, sí resulta interesante y ofrece un buen comportamiento del sistema de acumulación. Las circunstancias actuales de mercado, que carece de sistemas de acumulación de litio con precios de compra interesantes, no han permitido poder experimentar este sistema de acumulación en la instalación autónoma fotovoltaica ejecutada, tampoco se ha podido obtener el favor de ningún fabricante para ello. Actualmente hay disponibles sistemas de acumulación en litio que no se comercializan en España y que serían adecuados para el sistema de acumulación de energía propuesto en este estudio, que deja abierta las puertas para futuros trabajos de investigación. Las conclusiones económicas obtenidas, rentabilizan el uso de una instalación autónoma fotovoltaica con consumo instantáneo, sin acumulación de energía eléctrica. El futuro de conexión a red por parte de estas instalaciones, cuando se regule, aportará un incentivo económico para rentabilizar con menos tiempo las instalaciones autónomas fotovoltaicas, esto también deja la puerta abierta a futuros trabajos de investigación. El sistema de acumulación de energía aporta el mayor peso económico de inversión en este tipo de instalaciones. La instalación estudiada aporta indicadores económicos que la hacen rentable, pero se necesitaría que los precios de acumulación de la energía en sistemas eficientes estén comprendidos entre 100-200 €/kWh para que el sistema propuesto en este trabajo resulte atractivo a un potencial propietario de un vehículo eléctrico. ABSTRACT The current energy situation is untenable; it poses a scenario next focused on reaching a sustainable energy future, to allow economic development and social welfare. The environmental current situation is affected directly by the combustion of fossil fuels that in 2013 constituted 81 % of the primary energy used by the human being and they are the principal source human of greenhouse gases. The reports of the IPCC2, they reveal that the climate change has consolidated during the last years and in the conference of the UNO on climate change of Paris that will be celebrated at the end of 2015, there is claimed that the governments sign a universal agreement to limit the emission of greenhouse gases and to prevent that the increase of the global average temperature overcomes them 2°C. On the other hand, inside the cities it is specially worrying, for his direct effect on the human health, the environmental impact produced by the NOx emissions that generate the persons' transport and goods. The sector of the transport was responsible in 2012 of 27,9 % of the final consumption of energy. Once exposed the scenario and present environmental energy, in this thesis, it has analyzed the efficiency of an autonomous photovoltaic system for charging electric vehicles, and the use of the same with other workloads, with the objective to maximize the electrical energy generated and contribute to the use of clean energy that does not produce environmental impact. Since the first step for the development of the thesis did to itself a study of previous works beginning for the first applications of the photovoltaic power in the solar vehicles later to go on to more recent works focused on the power supply to the electrical vehicles. Also this study was done on the methodologies of simulation in the photovoltaic systems and in the shaped one of different components. Later they were chosen, inside the wide existing offer on the market, the components with technical characteristics more adapted for this type of facilities and for the needs that try to cover. From the technical parameters of the components chosen to form the autonomous installation and using models confirmed of different components, a model of simulation has developed in computer of the complete system with which simulations have been done by different manners of demand of electric power, according to the available manners of load in the electrical vehicle for single-phase alternating current of 230 V. Also there have been simulated different sizes of the photovoltaic generator and of the system of accumulation of electric power to be able to determine the influence of these parameters in the energy balances of the system. Using own resources the PhD student has realized a real installation of a photovoltaic system that includes system of accumulation and investing in a building of his property. For the accomplishment of the thesis, The Foundation of Promotion and Industrial Innovation (F2I2) it has facilitated to the PhD student a device that allows to realize the supply of the electrical vehicle in way 2 (this way uses an adapter that incorporates safety devices and communicates with the vehicle allowing to fit the speed of recharges) and that has been necessary for the developed works. The electrical network has been in use as system of support of the photovoltaic installation for allowing it her recharges in the way 2 that more power needs that provided by the photovoltaic installed system. There have been analyzed by means of simulation different rate of load that have been studied experimentally in the realized installation, simultaneously that have done to themselves tests that have reproduced by means of simulation with the same values of solar radiation and temperature in order the model contrasted. The experimental results have been compared by the obtained ones by means of simulation in order to characterize the behavior of the system of accumulation (supplied electric power and tension of exit in the batteries) and of the photovoltaic generator (photovoltaic supplied electric power). Finally, there has been realized an economic study of the autonomous photovoltaic executed and simulated installation. In the same one there has appeared the utilization of own funds (since really it has been carried out) and the utilization of financing, to determine two possible scenes that could be of usefulness to an owner of electrical vehicle. There have been compared the results obtained in both scenes proposed of the economic study of the system, as for the parameters of time of return of the investment, current clear value of the investment and rate hospitalizes of return of the same one. The technical obtained conclusions, they make the utilization of the system viable with the manners of load tested and another type of loads of that they take advantage the electrical generation of the system. The batteries offer better behavior when the photovoltaic contribution is present, but he does not consider to be suitable the connection of loads risen up to a system of accumulation of gel (lead - acid) as the one that has been in use, due to the behavior of this type of batteries before demands of intensity of electrical current raised. On the other hand, the behavior of this type of batteries with low values of intensity of electrical current to 10 To in absence of photovoltaic power, with the aim to use the generation of daily electric power accumulated in the system, yes turns out to be interesting and offers a good behavior of the system of accumulation. The current circumstances of market, which lacks systems of accumulation of lithium with interesting purchase prices, have not allowed to be able to experience this system of accumulation in the autonomous photovoltaic executed installation, neither one could have obtained the favor of any manufacturer for it. Nowadays there are available systems of accumulation in lithium that is not commercialized in Spain and that they would be adapted for the system of accumulation of energy proposed in this study, which makes the doors opened for future works of investigation. The economic obtained conclusions; they make more profitable the use of an autonomous photovoltaic installation with instantaneous consumption, without accumulation of electric power. The future of connection to network on the part of these facilities, when it is regulated, will contribute an economic incentive to make profitable with less time the autonomous photovoltaic facilities, this also leaves the door opened for future works of investigation. The system of accumulation of energy contributes the major economic weight of investment in this type of facilities. The studied installation contributes economic indicators that make her profitable, but it would be necessary that the prices of accumulation of the energy in efficient systems are understood between 100-200 € in order that the system proposed in this work turns out to be attractive to a proprietary potential of an electrical vehicle.
Resumo:
In this paper we present a heterogeneous collaborative sensor network for electrical management in the residential sector. Improving demand-side management is very important in distributed energy generation applications. Sensing and control are the foundations of the “Smart Grid” which is the future of large-scale energy management. The system presented in this paper has been developed on a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead-acid batteries, controllable appliances and smart metering. Therefore, there is a large number of energy variables to be monitored that allow us to precisely manage the energy performance of the house by means of collaborative sensors. The experimental results, performed on a real house, demonstrate the feasibility of the proposed collaborative system to reduce the consumption of electrical power and to increase energy efficiency.