37 resultados para Cold-formed Steel structures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold-drawn steel rods and wires retain significant residual stresses as a consequence of the manufacturing process. These residual stresses are known to be detrimental for the mechanical properties of the wires and their durability in aggressive environments. Steel makers are aware of the problem and have developed post-drawing processes to try and reduce the residual stresses on the wires. The present authors have studied this problem for a number of years and have performed a detailed characterization of the residual stress state inside cold-drawn rods, including both experimental and numerical techniques. High-energy synchrotron sources have been particularly useful for this research. The results have shown how residual stresses evolve as a consequence of cold-drawing and how they change with subsequent post-drawing treatments. The authors have been able to measure for the first time a complete residual strain profile along the diameter in both phases (ferrite and cementite) of a cold-drawn steel rod.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work a constitutive model is developed which permits the simulation of the low cycle fatigue behaviour in steel framed structures. In the elaboration of this model, the concepts of the mechanics of continuum medium are applied on lumped dissipative models. In this type of formulation an explicit coupling between the damage and the structural mechanical behaviour is employed, allowing the possibility of considering as a whole different coupled phenomena. A damage index is defined in order to model elastoplasticity coupled with damage and fatigue damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residual stresses developed during wire drawing influence the mechanical behavior and durability of steel wires used for prestressed concrete structures, particularly the shape of the stress–strain curve, stress relaxation losses, fatigue life, and environmental cracking susceptibility. The availability of general purpose finite element analysis tools and powerful diffraction techniques (X-rays and neutrons) has made it possible to predict and measure accurately residual stress fields in cold-drawn steel wires. Work carried out in this field in the past decade, shows the prospects and limitations of residual stress measurement, how the stress relaxation losses and environmentally-assisted cracking are correlated with the profile of residual stresses and how the performance of steel wires can be improved by modifying such a stress profile

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper summarizes the work developed in order to establish a framework for seismic retrofitting of bridges. In this context, the first objetive is to find a numerical model to evaluate the damage induced in a structure, under seismic action, as an index of its vulnerability. The model used has the adventage that is based on concepts of fracture mechanics and concentrated plasticity. As a result, the work is based on basic principles. The performance of this model is being evaluated. Some results of the computer program developed for this purpose are shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Es cada vez más frecuente la rehabilitación de patrimonio construido, tanto de obras deterioradas como para la adecuación de obras existentes a nuevos usos o solicitaciones. Se ha considerado el estudio del refuerzo de obras de fábrica ya que constituyen un importante número dentro del patrimonio tanto de edificación como de obra civil (sistemas de muros de carga o en estructuras principales porticadas de acero u hormigón empleándose las fábricas como cerramiento o distribución con elementos autoportantes). A la hora de reparar o reforzar una estructura es importante realizar un análisis de las deficiencias, caracterización mecánica del elemento y solicitaciones presentes o posibles; en el apartado 1.3 del presente trabajo se refieren acciones de rehabilitación cuando lo que se precisa no es refuerzo estructural, así como las técnicas tradicionales más habituales para refuerzo de fábricas que suelen clasificarse según se trate de refuerzos exteriores o interiores. En los últimos años se ha adoptado el sistema de refuerzo de FRP, tecnología con origen en los refuerzos de hormigón tanto de elementos a flexión como de soportes. Estos refuerzos pueden ser de láminas adheridas a la fábrica soporte (SM), o de barras incluidas en rozas lineales (NSM). La elección de un sistema u otro depende de la necesidad de refuerzo y tipo de solicitación predominante, del acceso para colocación y de la exigencia de impacto visual. Una de las mayores limitaciones de los sistemas de refuerzo por FRP es que no suele movilizarse la resistencia del material de refuerzo, produciéndose previamente fallo en la interfase con el soporte con el consecuente despegue o deslaminación; dichos fallos pueden tener un origen local y propagarse a partir de una discontinuidad, por lo que es preciso un tratamiento cuidadoso de la superficie soporte, o bien como consecuencia de una insuficiente longitud de anclaje para la transferencia de los esfuerzos en la interfase. Se considera imprescindible una caracterización mecánica del elemento a reforzar. Es por ello que el trabajo presenta en el capítulo 2 métodos de cálculo de la fábrica soporte de distintas normativas y también una formulación alternativa que tiene en cuenta la fábrica histórica ya que su caracterización suele ser más complicada por la heterogeneidad y falta de clasificación de sus materiales, especialmente de los morteros. Una vez conocidos los parámetros resistentes de la fábrica soporte es posible diseñar el refuerzo; hasta la fecha existe escasa normativa de refuerzos de FRP para muros de fábrica, consistente en un protocolo propuesto por la ACI 440 7R-10 que carece de mejoras por tipo de anclaje y aporta valores muy conservadores de la eficacia del refuerzo. Como se ha indicado, la problemática principal de los refuerzos de FRP en muros es el modo de fallo que impide un aprovechamiento óptimo de las propiedades del material. Recientemente se están realizando estudios con distintos métodos de anclaje para estos refuerzos, con lo que se incremente la capacidad última y se mantenga el soporte ligado al refuerzo tras la rotura. Junto con sistemas de anclajes por prolongación del refuerzo (tanto para láminas como para barras) se han ensayado anclajes con llaves de cortante, barras embebidas, o anclajes mecánicos de acero o incluso de FRP. Este texto resume, en el capítulo 4, algunas de las campañas experimentales llevadas a cabo entre los años 2000 y 2013 con distintos anclajes. Se observan los parámetros fundamentales para medir la eficacia del anclajes como son: el modo de fallo, el incremento de resistencia, y los desplazamientos que permite observar la ductilidad del refuerzo; estos datos se analizan en función de la variación de: tipo de refuerzo incluyéndose el tipo de fibra y sistema de colocación, y tipo de anclaje. Existen también parámetros de diseño de los propios anclajes. En el caso de barras embebidas se resumen en diámetro y material de la barra, acabado superficial, dimensiones y forma de la roza, tipo de adhesivo. En el caso de anclajes de FRP tipo pasador la caracterización incluye: tipo de fibra, sistema de fabricación del anclajes y diámetro del mismo, radio de expansión del abanico, espaciamiento longitudinal de anclajes, número de filas de anclajes, número de láminas del refuerzo, longitud adherida tras el anclaje; es compleja la sistematización de resultados de los autores de las campañas expuestas ya que algunos de estos parámetros varían impidiendo la comparación. El capítulo 5 presenta los ensayos empleados para estas campañas de anclajes, distinguiéndose entre ensayos de modo I, tipo tracción directa o arrancamiento, que servirían para sistemas NSM o para cuantificar la resistencia individual de anclajes tipo pasador; ensayos de modo II, tipo corte simple, que se asemeja más a las condiciones de trabajo de los refuerzos. El presente texto se realiza con objeto de abrir una posible investigación sobre los anclajes tipo pasador, considerándose que junto con los sistemas de barra embebida son los que permiten una mayor versatilidad de diseño para los refuerzos de FRP y siendo su eficacia aún difícil de aislar por el número de parámetros de diseño. Rehabilitation of built heritage is becoming increasingly frequent, including repair of damaged works and conditioning for a new use or higher loads. In this work it has been considered the study of masonry wall reinforcement, as most buildings and civil works have load bearing walls or at least infilled masonry walls in concrete and steel structures. Before repairing or reinforcing an structure, it is important to analyse its deficiencies, its mechanical properties and both existing and potential loads; chapter 1, section 4 includes the most common rehabilitation methods when structural reinforcement is not needed, as well as traditional reinforcement techniques (internal and external reinforcement) In the last years the FRP reinforcement system has been adopted for masonry walls. FRP materials for reinforcement were initially used for concrete pillars and beams. FRP reinforcement includes two main techniques: surface mounted laminates (SM) and near surface mounted bars (NSM); one of them may be more accurate according to the need for reinforcement and main load, accessibility for installation and aesthetic requirements. One of the main constraints of FRP systems is not reaching maximum load for material due to premature debonding failure, which can be caused by surface irregularities so surface preparation is necessary. But debonding (or delamination for SM techniques) can also be a consequence of insufficient anchorage length or stress concentration. In order to provide an accurate mechanical characterisation of walls, chapter 2 summarises the calculation methods included in guidelines as well as alternative formulations for old masonry walls as historic wall properties are more complicated to obtain due to heterogeneity and data gaps (specially for mortars). The next step is designing reinforcement system; to date there are scarce regulations for walls reinforcement with FRP: ACI 440 7R-10 includes a protocol without considering the potential benefits provided by anchorage devices and with conservative values for reinforcement efficiency. As noted above, the main problem of FRP masonry walls reinforcement is failure mode. Recently, some authors have performed studies with different anchorage systems, finding that these systems are able to delay or prevent debonding . Studies include the following anchorage systems: Overlap, embedded bars, shear keys, shear restraint and fiber anchors. Chapter 4 briefly describes several experimental works between years 2000 and 2013, concerning different anchorage systems. The main parameters that measure the anchorage efficiency are: failure mode, failure load increase, displacements (in order to evaluate the ductility of the system); all these data points strongly depend on: reinforcement system, FRP fibers, anchorage system, and also on the specific anchorage parameters. Specific anchorage parameters are a function of the anchorage system used. The embedded bar system have design variables which can be identified as: bar diameter and material, surface finish, groove dimensions, and adhesive. In FRP anchorages (spikes) a complete design characterisation should include: type of fiber, manufacturing process, diameter, fan orientation, anchor splay width, anchor longitudinal spacing and number or rows, number or FRP sheet plies, bonded length beyond anchorage devices,...the parameters considered differ from some authors to others, so the comparison of results is quite complicated. Chapter 5 includes the most common tests used in experimental investigations on bond-behaviour and anchorage characterisation: direct shear tests (with variations single-shear and double-shear), pullout tests and bending tests. Each of them may be used according to the data needed. The purpose of this text is to promote further investigation of anchor spikes, accepting that both FRP anchors and embedded bars are the most versatile anchorage systems of FRP reinforcement and considering that to date its efficiency cannot be evaluated as there are too many design uncertainties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Para el proyecto y cálculo de estructuras metálicas, fundamentalmente pórticos y celosías de cubierta, la herramienta más comúnmente utilizada son los programas informáticos de nudos y barras. En estos programas se define la geometría y sección de las barras, cuyas características mecánicas son perfectamente conocidas, y sobre las cuales obtenemos unos resultados de cálculo concretos en cuanto a estados tensionales y de deformación. Sin embargo el otro componente del modelo, los nudos, presenta mucha mayor complejidad a la hora de establecer sus propiedades mecánicas, fundamentalmente su rigidez al giro, así como de obtener unos resultados de estados tensionales y de deformación en los mismos. Esta “ignorancia” sobre el comportamiento real de los nudos, se salva generalmente asimilando a los nudos del modelo la condición de rígidos o articulados. Si bien los programas de cálculo ofrecen la posibilidad de introducir nudos con una rigidez intermedia (nudos semirrígidos), la rigidez de cada nudo dependerá de la geometría real de la unión, lo cual, dada la gran variedad de geometrías de uniones que en cualquier proyecto se nos presentan, hace prácticamente inviable introducir los coeficientes correspondientes a cada nudo en los modelos de nudos y barras. Tanto el Eurocódigo como el CTE, establecen que cada unión tendrá asociada una curva momento-rotación característica, que deberá ser determinada por los proyectistas mediante herramientas de cálculo o procedimientos experimentales. No obstante, este es un planteamiento difícil de llevar a cabo para cada proyecto. La consecuencia de esto es, que en la práctica, se realizan extensas comprobaciones y justificaciones de cálculo para las barras de las estructuras, dejando en manos de la práctica común la solución y puesta en obra de las uniones, quedando sin justificar ni comprobar la seguridad y el comportamiento real de estas. Otro aspecto que conlleva la falta de caracterización de las uniones, es que desconocemos como afecta el comportamiento real de éstas en los estados tensionales y de deformación de las barras que acometen a ellas, dudas que con frecuencia nos asaltan, no sólo en la fase de proyecto, sino también a la hora de resolver los problemas de ejecución que inevitablemente se nos presentan en el desarrollo de las obras. El cálculo mediante el método de los elementos finitos, es una herramienta que nos permite introducir la geometría real de perfiles y uniones, y nos permite por tanto abordar el comportamiento real de las uniones, y que está condicionado por su geometría. Por ejemplo, un caso típico es el de la unión de una viga a una placa o a un soporte soldando sólo el alma. Es habitual asimilar esta unión a una articulación. Sin embargo, el modelo por elementos finitos nos ofrece su comportamiento real, que es intermedio entre articulado y empotrado, ya que se transmite un momento y el giro es menor que el del apoyo simple. No obstante, la aplicación del modelo de elementos finitos, introduciendo la geometría de todos los elementos estructurales de un entramado metálico, tampoco resulta en general viable desde un punto de vista práctico, dado que requiere invertir mucho tiempo en comparación con el aumento de precisión que obtenemos respecto a los programas de nudos y barras, mucho más rápidos en la fase de modelización de la estructura. En esta tesis se ha abordado, mediante la modelización por elementos finitos, la resolución de una serie de casos tipo representativos de las uniones más comúnmente ejecutadas en obras de edificación, como son las uniones viga-pilar, estableciendo el comportamiento de estas uniones en función de las variables que comúnmente se presentan, y que son: •Ejecución de uniones viga-pilar soldando solo por el alma (unión por el alma), o bien soldando la viga al pilar por todo su perímetro (unión total). •Disposición o no de rigidizadores en los pilares •Uso de pilares de sección 2UPN en cajón o de tipo HEB, que son los tipos de soporte utilizados en casi el 100% de los casos en edificación. Para establecer la influencia de estas variables en el comportamiento de las uniones, y su repercusión en las vigas, se ha realizado un análisis comparativo entre las variables de resultado de los casos estudiados:•Estados tensionales en vigas y uniones. •Momentos en extremo de vigas •Giros totales y relativos en nudos. •Flechas. Otro de los aspectos que nos permite analizar la casuística planteada, es la valoración, desde un punto de vista de costos de ejecución, de la realización de uniones por todo el perímetro frente a las uniones por el alma, o de la disposición o no de rigidizadores en las uniones por todo el perímetro. Los resultados a este respecto, son estrictamente desde un punto de vista económico, sin perjuicio de que la seguridad o las preferencias de los proyectistas aconsejen una solución determinada. Finalmente, un tercer aspecto que nos ha permitido abordar el estudio planteado, es la comparación de resultados que se obtienen por el método de los elementos finitos, más próximos a la realidad, ya que se tiene en cuenta los giros relativos en las uniones, frente a los resultados obtenidos con programas de nudos y barras. De esta forma, podemos seguir usando el modelo de nudos y barras, más versátil y rápido, pero conociendo cuáles son sus limitaciones, y en qué aspectos y en qué medida, debemos ponderar sus resultados. En el último apartado de la tesis se apuntan una serie de temas sobre los que sería interesante profundizar en posteriores estudios, mediante modelos de elementos finitos, con el objeto de conocer mejor el comportamiento de las uniones estructurales metálicas, en aspectos que no se pueden abordar con los programas de nudos y barras. For the project and calculation of steel structures, mainly building frames and cover lattices, the tool more commonly used are the node and bars model computer programs. In these programs we define the geometry and section of the bars, whose mechanical characteristics are perfectly known, and from which we obtain the all calculation results of stresses and displacements. Nevertheless, the other component of the model, the nodes, are much more difficulty for establishing their mechanical properties, mainly the rotation fixity coefficients, as well as the stresses and displacements. This "ignorance" about the real performance of the nodes, is commonly saved by assimilating to them the condition of fixed or articulated. Though the calculation programs offer the possibility to introducing nodes with an intermediate fixity (half-fixed nodes), the fixity of every node will depend on the real connection’s geometry, which, given the great variety of connections geometries that in a project exist, makes practically unviable to introduce the coefficients corresponding to every node in the models of nodes and bars. Both Eurocode and the CTE, establish that every connection will have a typical moment-rotation associated curve, which will have to be determined for the designers by calculation tools or experimental procedures. Nevertheless, this one is an exposition difficult to carry out for each project. The consequence of this, is that in the practice, in projects are extensive checking and calculation reports about the bars of the structures, trusting in hands of the common practice the solution and execution of the connections, resulting without justification and verification their safety and their real behaviour. Another aspect that carries the lack of the connections characterization, is that we don´t know how affects the connections real behaviour in the stresses and displacements of the bars that attack them, doubts that often assault us, not only in the project phase, but also at the moment of solving the execution problems that inevitably happen in the development of the construction works. The calculation by finite element model is a tool that allows us to introduce the real profiles and connections geometry, and allows us to know about the real behaviour of the connections, which is determined by their geometry. Typical example is a beam-plate or beam-support connection welding only by the web. It is usual to assimilate this connection to an articulation or simple support. Nevertheless, the finite element model determines its real performance, which is between articulated and fixed, since a moment is transmitted and the relative rotation is less than the articulation’s rotation. Nevertheless, the application of the finite element model, introducing the geometry of all the structural elements of a metallic structure, does not also turn out to be viable from a practical point of view, provided that it needs to invest a lot of time in comparison with the precision increase that we obtain opposite the node and bars programs, which are much more faster in the structure modelling phase. In this thesis it has been approached, by finite element modelling, the resolution of a representative type cases of the connections commonly used in works of building, since are the beam-support connections, establishing the performance of these connections depending on the variables that commonly are present, which are: •Execution of beam-support connections welding only the web, or welding the beam to the support for the whole perimeter. •Disposition of stiffeners in the supports •Use 2UPN in box section or HEB section, which are the support types used in almost 100% building cases. To establish the influence of these variables in the connections performance, and the repercussion in the beams, a comparative analyse has been made with the resulting variables of the studied cases: •Stresses states in beams and connections. •Bending moments in beam ends. •Total and relative rotations in nodes. •Deflections in beams. Another aspect that the study allows us to analyze, is the valuation, from a costs point of view, of the execution of connections for the whole perimeter opposite to the web connections, or the execution of stiffeners. The results of this analyse, are strictly from an economic point of view, without prejudice that the safety or the preferences of the designers advise a certain solution. Finally, the third aspect that the study has allowed us to approach, is the comparison of the results that are obtained by the finite element model, nearer to the real behaviour, since the relative rotations in the connections are known, opposite to the results obtained with nodes and bars programs. So that, we can use the nodes and bars models, more versatile and quick, but knowing which are its limitations, and in which aspects and measures, we must weight the results. In the last part of the tesis, are relationated some of the topics on which it would be interesting to approach in later studies, with finite elements models, in order to know better the behaviour of the structural steel connections, in aspects that cannot be approached by the nodes and bars programs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

System identification deals with the problem of building mathematical models of dynamical systems based on observed data from the system" [1]. In the context of civil engineering, the system refers to a large scale structure such as a building, bridge, or an offshore structure, and identification mostly involves the determination of modal parameters (the natural frequencies, damping ratios, and mode shapes). This paper presents some modal identification results obtained using a state-of-the-art time domain system identification method (data-driven stochastic subspace algorithms [2]) applied to the output-only data measured in a steel arch bridge. First, a three dimensional finite element model was developed for the numerical analysis of the structure using ANSYS. Modal analysis was carried out and modal parameters were extracted in the frequency range of interest, 0-10 Hz. The results obtained from the finite element modal analysis were used to determine the location of the sensors. After that, ambient vibration tests were conducted during April 23-24, 2009. The response of the structure was measured using eight accelerometers. Two stations of three sensors were formed (triaxial stations). These sensors were held stationary for reference during the test. The two remaining sensors were placed at the different measurement points along the bridge deck, in which only vertical and transversal measurements were conducted (biaxial stations). Point estimate and interval estimate have been carried out in the state space model using these ambient vibration measurements. In the case of parametric models (like state space), the dynamic behaviour of a system is described using mathematical models. Then, mathematical relationships can be established between modal parameters and estimated point parameters (thus, it is common to use experimental modal analysis as a synonym for system identification). Stable modal parameters are found using a stabilization diagram. Furthermore, this paper proposes a method for assessing the precision of estimates of the parameters of state-space models (confidence interval). This approach employs the nonparametric bootstrap procedure [3] and is applied to subspace parameter estimation algorithm. Using bootstrap results, a plot similar to a stabilization diagram is developed. These graphics differentiate system modes from spurious noise modes for a given order system. Additionally, using the modal assurance criterion, the experimental modes obtained have been compared with those evaluated from a finite element analysis. A quite good agreement between numerical and experimental results is observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

El presente trabajo trata de elementos reforzados con barras de armadura y Fibras Metálicas Recicladas (FMR). El objetivo principal es mejorar el comportamiento a fisuración de elementos sometidos a flexión pura y a flexión compuesta, aumentando en consecuencia las prestaciones en servicio de aquellas estructuras con requerimientos estrictos con respecto al control de fisuración. Entre éstas últimas se encuentran las estructuras integrales, es decir aquellas estructuras sin juntas (puentes o edificios), sometidas a cargas gravitatorias y deformaciones impuestas en los elementos horizontales debidas a retracción, fluencia y temperatura. Las FMR son obtenidas a partir de los neumáticos fuera de uso, y puesto que el procedimiento de reciclado se centra en el caucho en vez que en el acero, su forma es aleatoria y con longitud variable. A pesar de que la eficacia del fibrorefuerzo mediante FMR ha sido demostrada en investigaciones anteriores, la innovación que representa este trabajo consiste en proponer la acción combinada de barras convencionales y FMR en la mejora del comportamiento a fisuración. El objetivo es por tanto mejorar la sostenibilidad del proyecto de la estructura en HA al utilizar materiales reciclados por un lado, y aumentando por el otro la durabilidad. En primer lugar, se presenta el estado del arte con respecto a la fisuración en elementos de HA, que sucesivamente se amplía a elementos reforzados con barras y fibras. Asimismo, se resume el método simplificado para el análisis de columnas de estructuras sin juntas ya propuesto por Pérez et al., con particular énfasis en aquellos aspectos que son incompatibles con la acción de las fibras a nivel seccional. A continuación, se presenta un modelo para describir la deformabilidad seccional y la fisuración en elementos en HA, que luego se amplía a aquellos elementos reforzados con barras y fibras, teniendo en cuenta también los efectos debidos a la retracción (tension stiffening negativo). El modelo es luego empleado para ampliar el método simplificado para el análisis de columnas. La aportación consiste por tanto en contar con una metodología amplia de análisis para este tipo de elementos. Seguidamente, se presenta la campaña experimental preliminar que ha involucrado vigas a escala reducida sometidas a flexión simple, con el objetivo de validar la eficiencia y la usabilidad en el hormigón de las FMR de dos diferentes tipos, y su comportamiento con respecto a fibras de acero comerciales. Se describe a continuación la campaña principal, consistente en ensayos sobre ocho vigas en flexión simple a escala 1:1 (variando contenido en FRM, Ø/s,eff y recubrimiento) y doce columnas a flexión compuesta (variando contenido en FMR, Ø/s,eff y nivel de fuerza axil). Los resultados obtenidos en la campaña principal son presentados y comentados, resaltando las mejoras obtenidas en el comportamiento a fisuración de las vigas y columnas, y la rigidez estructural de las columnas. Estos resultados se comparan con las predicciones del modelo propuesto. Los principales parámetros estudiados para describir la fisuración y el comportamiento seccional de las vigas son: la separación entre fisuras, el alargamiento medio de las armaduras y la abertura de fisura, mientras que en los ensayos de las columnas se ha contrastado las leyes momento/curvatura, la tensión en las barras de armadura y la abertura de fisura en el empotramiento en la base. La comparación muestra un buen acuerdo entre las predicciones y los resultados experimentales. Asimismo, se nota la mejora en el comportamiento a fisuración debido a la incorporación de FMR en aquellos elementos con cuantías de armadura bajas en flexión simple, en elementos con axiles bajos y para el control de la fisuración en elementos con grandes recubrimientos, siendo por tanto resultados de inmediato impacto en la práctica ingenieril (diseño de losas, tanques, estructuras integrales, etc.). VIIIComo punto final, se presentan aplicaciones de las FMR en estructuras reales. Se discuten dos casos de elementos sometidos a flexión pura, en particular una viga simplemente apoyada y un tanque para el tratamiento de agua. En ambos casos la adicción de FMR al hormigón lleva a mejoras en el comportamiento a fisuración. Luego, utilizando el método simplificado para el análisis en servicio de columnas de estructuras sin juntas, se calcula la máxima longitud admisible en casos típicos de puentes y edificación. En particular, se demuestra que las limitaciones de la práctica ingenieril actual (sobre todo en edificación) pueden ser aumentadas considerando el comportamiento real de las columnas en HA. Finalmente, los mismos casos son modificados para considerar el uso de MFR, y se presentan las mejoras tanto en la máxima longitud admisible como en la abertura de fisura para una longitud y deformación impuesta. This work deals with elements reinforced with both rebars and Recycled Steel Fibres (RSFs). Its main objective is to improve cracking behaviour of elements subjected to pure bending and bending and axial force, resulting in better serviceability conditions for these structures demanding keen crack width control. Among these structures a particularly interesting type are the so-called integral structures, i.e. long jointless structures (bridges and buildings) subjected to gravitational loads and imposed deformations due to shrinkage, creep and temperature. RSFs are obtained from End of Life Tyres, and due to the recycling process that is focused on the rubber rather than on the steel they come out crooked and with variable length. Although the effectiveness of RSFs had already been proven by previous research, the innovation of this work consists in the proposing the combined action of conventional rebars and RSFs to improve cracking behaviour. Therefore, the objective is to improve the sustainability of RC structures by, on the one hand, using recycled materials, and on the other improving their durability. A state of the art on cracking in RC elements is firstly drawn. It is then expanded to elements reinforced with both rebars and fibres (R/FRC elements). Finally, the simplified method for analysis of columns of long jointless structures already proposed by Pérez et al. is resumed, with a special focus on the points that conflict when taking into account the action of fibres. Afterwards, a model to describe sectional deformability and cracking of R/FRC elements is presented, taking also into account the effect of shrinkage (negative tension stiffening). The model is then used to implement the simplified method for columns. The novelty represented by this is that a comprehensive methodology to analyse this type of elements is presented. A preliminary experimental campaign consisting in small beams subjected to pure bending is described, with the objective of validating the effectiveness and usability in concrete of RSFs of two different types, and their behaviour when compared with commercial steel fibres. With the results and lessons learnt from this campaign in mind, the main experimental campaign is then described, consisting in cracking tests of eight unscaled beams in pure bending (varying RSF content, Ø/s,eff and concrete cover) and twelve columns subjected to imposed displacement and axial force (varying RSF content, Ø/s,eff and squashing load ratio). The results obtained from the main campaign are presented and discussed, with particular focus on the improvement in cracking behaviour for the beams and columns, and structural stiffness for the columns. They are then compared with the proposed model. The main parameters studied to describe cracking and sectional behaviours of the beam tests are crack spacing, mean steel strain and crack width, while for the column tests these were moment/curvature, stress in rebars and crack with at column embedment. The comparison showed satisfactory agreement between experimental results and model predictions. Moreover, it is pointed out the improvement in cracking behaviour due to the addition of RSF for elements with low reinforcement ratios, elements with low squashing load ratios and for crack width control of elements with large concrete covers, thus representing results with a immediate impact in engineering practice (slab design, tanks, integral structures, etc.). Applications of RSF to actual structures are finally presented. Two cases of elements in pure bending are presented, namely a simple supported beam and a water treatment tank. In both cases the addition of RSF to concrete leads to improvements in cracking behaviour. Then, using the simplified model for the serviceability analysis of columns of jointless structures, the maximum achievable jointless length of typical cases of a bridge and building is obtained. In XIIparticular, it is shown how the limitations of current engineering practice (this is especially the case of buildings) can be increased by considering the actual behaviour of RC supports. Then, the same cases are modified considering the use of RSF, and the improvements both in maximum achievable length and in crack width for a given length and imposed strain at the deck/first floor are shown.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The carbonation of concrete or the chlorides ingress in such quantity to reach the level of bars is triggers of reinforcement corrosion. One of the most significant effects of reinforcing steel corrosion on reinforced concrete structures is the decline in the ductility-related properties of the steel. Reinforcement ductility has a decisive effect on the overall ductility of reinforced concrete structures. Different Codes classify the type of steel depending on their ductility defined by the minimum values of several parameters. Using indicators of ductility associating different properties can be advantageous on many occasions. It is considered necessary to define the ductility by means of a single parameter that considers strength values and deformation simultaneously. There are a number of criteria for defining steel ductility by a single parameter. The present experimental study addresses the variation in the ductility of concrete-embedded steel bars when exposed to accelerated corrosion. This paper analyzes the suitability of a new indicator of ductility used in corroded bars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prestressed structures are susceptible to relaxation losses which are of significant importance in structural design. After being manufactured, prestressing wires are coiled to make their storage and transportation easier. The possible deleterious effects of this operation on the stress relaxation behavior of prestressing steel wires are usually neglected, though it has been noticed by manufacturers and contractors that when relaxation tests are carried out after a long-time storage, on occasions relaxation losses are higher than those measured a short time after manufacturing. The influence of coiling on the relaxation losses is checked by means of experimental work and confirmed with a simple analytical model. The results show that some factors like initial residual stresses, excessively long-time storage or storage at high temperatures, can trigger or accentuate this damage. However, it is also shown that if the requirements of standards are fulfilled (minimum coiling diameters) these effects can be neglected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of reinforcing stainless steels (SS) in concrete have proved to be one of the most effective methods to guarantee the passivity of reinforced concrete structures exposed to chloride contaminated environment. The present research studies the corrosion behaviour of a new duplex SS reinforcements with low nickel content (LND) (more economicaly compatible) is compared with the conventional austenitic AISI 304 SS and duplex AISI 2304 SS. Corrosion behaviour of ribbed SS reinforcements was studied in mortars with chloride content (0, 0.4, 2 and 4% Cl ⎯ ) using linear polarization resistance and potentiostatic pulses technique, Ecorr and Rp values were monitored over the exposure time. The obtained icorr data for the new duplex stainless steel LND no afforded passivity breakdown after one year exposure

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water storage tanks of hotel trains suffered pitting corrosion. To identify the cause, the tanks were subjected to a detailed metallographic study and the chemical composition of the austenitic stainless steels used in their construction was determined. Both the tank water and the corrosion products were further examined by physicochemical and microbiological testing. Corrosion was shown to be related to an incompatibility between the chloride content of the water and the base and filler metals of the tanks. These findings formed the basis of recommendations aimed at the prevention and control of corrosion in such tanks. Se han detectado problemas de corrosión por picaduras en los depósitos de agua de trenes hotel. Para identificar las causas se llevó a cabo un detallado estudio metalográfico así como de la composición química de los aceros inoxidables austeníticos utilizados en su construcción. También se realizaron estudios fisicoquímicos y microbiológicos de los productos de corrosión. Se ha encontrado que los problemas de corrosión están relacionados con la incompatibilidad entre el contenido en cloruros del agua y los metales base y de aporte de la soldadura de los tanques. En base a estos hallazgos se proponen una serie de recomendaciones encaminadas a la prevención y control de la corrosión de dichos depósitos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of the temperature and stretching levels used in the stress-relieving treatment of cold-drawn eutectoid steel wires are evaluated with the aim of improving the stress relaxation behavior and the resistance to hydrogen embrittlement. Five industrial treatments are studied, combining three temperatures (330, 400, and 460 °C) and three stretching levels (38, 50 and 64% of the rupture load). The change of the residual stress produced by the treatments is taken into consideration to account for the results. Surface residual stresses allow us to explain the time to failure in standard hydrogen embrittlement tests

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present and discuss an algorithm to identify and characterize the long icosahedral structures (staggered pentagonal nanowires with 1-5-1-5 atomic structure) that appear in Molecular Dynamics simulations of metallic nanowires of different species subjected to stretching. The use of this algorithm allows the identification of pentagonal rings forming the icosahedral structure as well as the determination of its number np , and the maximum length of the pentagonal nanowire Lpm. The algorithm is tested with some ideal structures to show its ability to discriminate between pentagonal rings and other ring structures. We applied the algorithm to Ni nanowires with temperatures ranging between 4K and 865K, stretched along the [111], [100] and [110] directions. We studied statistically the formation of pentagonal nanowires obtaining the distributions of length Lpm and number of rings np as function of the temperature. The Lpm distribution presents a peaked shape, with peaks located at fixed distances whose separation corresponds to the distance between two consecutive pentagonal rings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La durabilidad de las estructuras de hormigón armado no es ilimitada, en especial en determinados ambientes. El ingreso de agentes agresivos en el hormigón, fundamentalmente dióxido de carbono e iones cloruros, rebasando el espesor del recubrimiento y alcanzando las armaduras, reducen el alto pH del hormigón hasta alcanzar un umbral crítico, por debajo del cual, el acero queda despasivado. Posteriormente, si existe el suficiente aporte de humedad y oxígeno, el acero se corroe, lo que supone drásticas reducciones de la vida de servicio de estas estructuras y su inevitable reparación. La utilización de armaduras de acero inoxidable es una alternativa que está recibiendo cada vez más consideración. Su resistencia a la corrosión en los ambientes más agresivos, incluso con ataque de cloruros, lo convierte en el material idóneo para prolongar de forma muy considerable la vida útil de la estructura. En este trabajo se ha evaluado el comportamiento mecánico y estructural, y de resistencia a la corrosión, de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el EN 1.4482 (AISI 2001), y se ha comparado con el inoxidable austenítico más utilizado, el EN 1.4301 (AISI 304), con el dúplex EN 1.4362 (AISI 2304) y con el tradicional acero al carbono B-500-SD. El estudio mecánico y estructural se ha realizado en tres niveles diferentes: a nivel de barra, estudiando las propiedades mecánicas y de ductilidad de los cuatro aceros citados; a nivel de sección, estudiando su comportamiento a flexión con diferentes cuantías de armado por medio de los diagramas momento-curvatura; y a nivel de pieza, ensayando una serie de vigas armadas con diferentes aceros y cuantías, y comprobando su comportamiento a desplazamiento y resistencia por medio de los diagramas carga-desplazamiento. El estudio de resistencia a la corrosión se ha realizado embebiendo barras corrugadas, de los tres aceros inoxidables mencionados, en probetas de mortero contaminadas con diferentes cantidades de cloruros, y realizando mediciones electroquímicas durante un periodo de al menos un año. Se han preparado probetas de mortero para dos comparativas diferentes. La primera, manteniendo las probetas en un desecador con el 95 % de humedad relativa durante todo el periodo de mediciones. La segunda, sumergiendo parcialmente las probetas en una solución tampón para carbonatar el mortero. Los resultados de los ensayos mecánicos han demostrado dos aspectos diferentes. Uno, que las armaduras de acero inoxidable tienen un comportamiento muy similar a las de acero al carbono en lo referente a las resistencias alcanzadas, en el límite elástico y en rotura, pero distinto en cuanto al módulo de deformación longitudinal, cuyo valor es claramente inferior al del acero al carbono, por lo que su utilización en las estructuras de hormigón necesita tener en cuenta ese dato en los análisis lineales de cálculo. El segundo aspecto es que las armaduras de acero inoxidable laminadas en caliente presentan una ductilidad muy superior a las de acero al carbono, por lo que ofrecen una mayor seguridad frente a su rotura o al colapso de la estructura, lo que se debe tener en cuenta en el análisis de cálculo plástico. En cambio, las armaduras de acero inoxidable laminadas en frío sólo cumplen con los límites mínimos de ductilidad establecidos en la instrucción EHE-08 para los aceros soldables, y no para los aceros con características especiales de ductilidad. El estudio a nivel de sección refleja la paradoja de obtener secciones menos dúctiles con las armaduras de acero inoxidable laminadas en caliente que con las armaduras de acero al carbono. Para subsanarlo, se definen los conceptos de curvatura última de rotura y ductilidad de la sección en rotura, que tienen en cuenta las altas deformaciones alcanzadas por las armaduras de acero inoxidable. Los resultados a nivel de pieza permiten identificar el comportamiento estructural del hormigón armado con barras corrugadas de acero inoxidable y compararlo con el de las estructuras de hormigón armado convencionales, verificando los resultados experimentales con los teóricos obtenidos con la formulación recogida en la instrucción EHE- 08. Los ensayos de resistencia a la corrosión por cloruros demuestran, durante el primer año y medio de vida de las probetas, un comportamiento muy similar entre el nuevo acero inoxidable dúplex bajo en níquel y el austenítico y el dúplex utilizados para la comparación, incluso para las probetas carbonatadas. Por último, se añade una comparativa económica, realizada sobre dos edificaciones tipo, para cuantificar el sobrecoste que supone la utilización de armaduras de acero inoxidable respecto a las de acero al carbono. El alto coste inicial de las armaduras de acero inoxidable se ve compensado en el coste final de la estructura de muy diferentes formas, principalmente dependiendo del grado de acero elegido y de si se emplean en el total de la estructura o solamente en los elementos más expuestos. The durability of the concrete structures is limited, especially in certain environments. The attack of aggressive agents in the concrete, mainly carbon dioxide and chloride ions, penetrating the thickness of concrete cover and reaching the reinforcements, reduce the high pH of concrete to the point of reaching a critical threshold, under which, the steel despasivates. Therefore, if there is enough humidity and oxygen, the steel corroes, causing drastic reductions in the service life of these structures and its inevitable repair. Despite the high initial cost compared to carbon steel, the usage of stainless steel reinforcements is an alternative with a major consideration nowadays. Its resistance to corrosion in the most aggressive atmospheres, including chlorides attack, makes the stainless steel a suitable material to extend considerably its lifetime. In this study, it’s been evaluated the mechanical and structural behaviour, and the corrosion resistance, of a new low-nickel duplex stainless steel EN 1.4482 (AISI 2001), and it has been compared with the most widely used austenitic type EN 1.4301 (AISI 304), with duplex steel EN 1.4362 (AISI 2304) and with the traditional carbon steel B-500-SD. The mechanical and structural study has been carried out in three different levels: bar level, studying mechanical properties and ductility of the four steels; section level, studying its behaviour when blending with different amounts of reinforcement through the moment-curvature diagrams; and structural element level, testing a series of reinforced beams with different steels and amounts, and checking its sag and resistance through the load-deflection diagrams. The corrosion resistance study was performed by embedding ribbed bars, using the three stainless steel listed, on mortar specimens contaminated with different amounts of chlorides, and taking electrochemical measurements over a period of at least one year. Mortar specimens have been prepared for two different comparisons. The first, keeping the specimens at 95% of relative humidity during the measurement period. The second, immersing the specimens partially in a carbonate buffer solution. The results of those tests have proved two different aspects. Firstly, that stainless steel reinforcements show a very similar behaviour to carbon steel, according to the reached levels of mechanical resistance, yield stress and steel strength, but a different behaviour in Young’s modulus, which value is clearly lower than the carbon steel. Therefore, when using in concrete structures it is need to consider on that point the existing calculus of linear analysis. The second aspect is that stainless steel reinforcement manufactured by hot-rolling process show a very higher ductility than carbon steel, offering a better security on cracks or structure collapse, which it has to be taken into account on plastic calculus analysis. However, the stainless steel reinfor9 cement cold-rolled bars only meet the minimum thresholds of ductility established by EHE-08 for welded steel, and not for steels with special ductility. The results at the section level reflect the paradox of getting less ductile sections with hot rolled stainless steel reinforcement than with carbon steel reinforcements. To overcome that, the concepts of last break curvature and break ductility section have been defined, which take into account the high deformation value achieved by stainless steel reinforcements. The results at the structural element level allow to identify the structural behaviour of reinforced concrete with stainless steel reinforcements and compared with that of conventional steel reinforcement, contrasting the experimental with the theoretical results obtained from the formulation contained in the instruction EHE-08. Tests on resistance of chloride corrosion show during the first year and a half of specimens life, a similar behaviour between the new low nickel duplex stainless steel and austenitic and duplex used for comparison, even for carbonated specimens. Finally, it has been included an economic comparison on two differents building types, to quantify the additional cost involved on the use of stainless steel reinforcement compared to that of carbon steel. The high initial cost of stainless steel reinforcements is offset in the final cost of the structure in many different ways, mainly depending on the chosen steel grade and whether the reinforcement is used in the total structure or only in risky structural elements.