25 resultados para AC Generator
Resumo:
This paper describes a practical activity, part of the renewable energy course where the students have to build their own complete wind generation system, including blades, PM-generator, power electronics and control. After connecting the system to the electric grid the system has been tested during real wind scenarios. The paper will describe the electric part of the work surface-mounted permanent magnet machine design criteria as well as the power electronics part for the power control and the grid connection. A Kalman filter is used for the voltage phase estimation and current commands obtained in order to control active and reactive power. The connection to the grid has been done and active and reactive power has been measured in the system.
Resumo:
The implementation of abstract machines involves complex decisions regarding, e.g., data representation, opcodes, or instruction specialization levéis, all of which affect the final performance of the emulator and the size of the bytecode programs in ways that are often difficult to foresee. Besides, studying alternatives by implementing abstract machine variants is a time-consuming and error-prone task because of the level of complexity and optimization of competitive implementations, which makes them generally difficult to understand, maintain, and modify. This also makes it hard to genérate specific implementations for particular purposes. To ameliorate those problems, we propose a systematic approach to the automatic generation of implementations of abstract machines. Different parts of their definition (e.g., the instruction set or the infernal data and bytecode representation) are kept sepárate and automatically assembled in the generation process. Alternative versions of the abstract machine are therefore easier to produce, and variants of their implementation can be created mechanically, with specific characteristics for a particular application if necessary. We illustrate the practicality of the approach by reporting on an implementation of a generator of production-quality WAMs which are specialized for executing a particular fixed (set of) program(s). The experimental results show that the approach is effective in reducing emulator size.
Resumo:
We describe lpdoc, a tool which generates documentation manuals automatically from one or more logic program source files, written in Ciao, ISO-Prolog, and other (C)LP languages. It is particularly useful for documenting library modules, for which it automatically generates a rich description of the module interface. However, it can also be used quite successfully to document full applications. A fundamental advantage of using lpdoc is that it helps maintaining a true correspondence between the program and its documentation, and also identifying precisely to what versión of the program a given printed manual corresponds. The quality of the documentation generated can be greatly enhanced by including within the program text assertions (declarations with types, modes, etc. ...) for the predicates in the program, and machine-readable comments. One of the main novelties of lpdoc is that these assertions and comments are written using the Ciao system asseriion language, which is also the language of communication between the compiler and the user and between the components of the compiler. This allows a significant synergy among specification, debugging, documentation, optimization, etc. A simple compatibility library allows conventional (C)LP systems to ignore these assertions and comments and treat normally programs documented in this way. The documentation can be generated interactively from emacs or from the command line, in many formats including texinfo, dvi, ps, pdf, info, ascii, html/css, Unix nroff/man, Windows help, etc., and can include bibliographic citations and images, lpdoc can also genérate "man" pages (Unix man page format), nicely formatted plain ASCII "readme" files, installation scripts useful when the manuals are included in software distributions, brief descriptions in html/css or info formats suitable for inclusión in on-line Índices of manuals, and even complete WWW and info sites containing on-line catalogs of documents and software distributions. The lpdoc manual, all other Ciao system manuals, and parts of this paper are generated by lpdoc.
Resumo:
We describe lpdoc, a tool which generates documentation manuals automatically from one or more logic program source files, written in ISO-Prolog, Ciao, and other (C)LP languages. It is particularly useful for documenting library modules, for which it automatically generates a rich description of the module interface. However, it can also be used quite successfully to document full applications. The documentation can be generated in many formats including t e x i n f o, dvi, ps, pdf, inf o, html/css, Unix nrof f/man, Windows help, etc., and can include bibliographic citations and images, lpdoc can also genérate "man" pages (Unix man page format), nicely formatted plain ascii "readme" files, installation scripts useful when the manuals are included in software distributions, brief descriptions in html/css or inf o formats suitable for inclusión in on-line Índices of manuals, and even complete WWW and inf o sites containing on-line catalogs of documents and software distributions. A fundamental advantage of using lpdoc is that it helps maintaining a true correspondence between the program and its documentation, and also identifying precisely to what versión of the program a given printed manual corresponds. The quality of the documentation generated can be greatly enhanced by including within the program text assertions (declarations with types, modes, etc. ...) for the predicates in the program, and machine-readable comments. These assertions and comments are written using the Ciao system assertion language. A simple compatibility library allows conventional (C)LP systems to ignore these assertions and comments and treat normally programs documented in this way. The lpdoc manual, all other Ciao system manuals, and most of this paper, are generated by lpdoc.
Resumo:
Lpdoc is an automatic program documentation generator for (C)LP systems. Lpdoc generates a reference manual automatically from one or more source files for a logic program (including ISO-Prolog, Ciao, many CLP systems, ...). It is particularly useful for documenting library modules, for which it automatically generates a description of the module interface. However, lpdoc can also be used quite successfully to document full applications and to generate nicely formatted plain ascii "readme" files. A fundamental advantage of using lpdoc to document programs is that it is much easier to maintain a true correspondence between the program and its documentation, and to identify precisely to what version of the program a given printed manual corresponds. The quality of the documentation generated can be greatly enhanced by including within the program text: • assertions (types, modes, etc. ...) for the predicates in the program, and • machine-readable comments (in the "literate programming" style). The assertions and comments included in the source file need to be written using the Ciao system assertion language. A simple compatibility library is available to make traditional (constraint) logic programming systems ignore these assertions and comments allowing normal treatment of programs documented in this way. The documentation is currently generated in HTML or texinf o format. From the texinf o output, printed and on-line manuals in several formats (dvi, ps, info, etc.) can be easily generated automatically, using publicly available tools, lpdoc can also generate 'man' pages (Unix man page format) as well as brief descriptions in html or emacs info formats suitable for inclusion in an on-line index of applications. In particular, lpdoc can create and maintain fully automatically WWW and info sites containing on-line versions of the documents it produces. The lpdoc manual (and the Ciao system manuals) are generated by lpdoc. Lpdoc is distributed under the GNU general public license. Note: lpdoc is fully supported on Linux, Mac OS X, and other Un*x-like systems. Due to the use of several Un*x-related utilities, some documentation back-ends may require Cygwin under Win32. This documentation corresponds to version 3.0 (2011/7/7, 16:33:15 CEST).
Resumo:
Mersenne Twister (MT) uniform random number generators are key cores for hardware acceleration of Monte Carlo simulations. In this work, two different architectures are studied: besides the classical table-based architecture, a different architecture based on a circular buffer and especially targeting FPGAs is proposed. A 30% performance improvement has been obtained when compared to the fastest previous work. The applicability of the proposed MT architectures has been proven in a high performance Gaussian RNG.
Resumo:
Renewable energy hybrid systems and mini-grids for electrification of rural areas are known to be reliable and more cost efficient than grid extension or only-diesel based systems. However, there is still some uncertainty in some areas, for example, which is the most efficient way of coupling hybrid systems: AC, DC or AC-DC? With the use of Matlab/Simulink a mini-grid that connects a school, a small hospital and an ecotourism hostel has been modelled. This same mini grid has been coupled in the different possible ways and the system’s efficiency has been studied. In addition, while keeping the consumption constant, the generation sources and the consumption profile have been modified and the effect on the efficiency under each configuration has also been analysed. Finally different weather profiles have been introduced and, again, the effect on the efficiency of each system has been observed.
Resumo:
The Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Safety Council (CSN), has been applied to a thermo-hydraulical analysis of a Westinghouse 3-loop PWR plant by means of the dynamic event trees (DET) for Steam Generator Tube Rupture (SGTR) sequences. The ISA methodology allows obtaining the SGTR Dynamic Event Tree taking into account the operator actuation times. Simulations are performed with SCAIS (Simulation Code system for Integrated Safety Assessment), which includes a dynamic coupling with MAAP thermal hydraulic code. The results show the capability of the ISA methodology and SCAIS platform to obtain the DET of complex sequences.
Resumo:
This paper analyzes the correlation between the fluctuations of the electrical power generated by the ensemble of 70 DC/AC inverters from a 45.6 MW PV plant. The use of real electrical power time series from a large collection of photovoltaic inverters of a same plant is an impor- tant contribution in the context of models built upon simplified assumptions to overcome the absence of such data. This data set is divided into three different fluctuation categories with a clustering proce- dure which performs correctly with the clearness index and the wavelet variances. Afterwards, the time dependent correlation between the electrical power time series of the inverters is esti- mated with the wavelet transform. The wavelet correlation depends on the distance between the inverters, the wavelet time scales and the daily fluctuation level. Correlation values for time scales below one minute are low without dependence on the daily fluctuation level. For time scales above 20 minutes, positive high correlation values are obtained, and the decay rate with the distance depends on the daily fluctuation level. At intermediate time scales the correlation depends strongly on the daily fluctuation level. The proposed methods have been implemented using free software. Source code is available as supplementary material.
Resumo:
The cutoff frequencies of an EMI filter are normally given by the noise attenuation requirements the filter has to fulfill. In order to select the component values of the filter elements, i.e. inductances and capacitances, an additional design criterium is needed. In this paper the effect of the EMI filter input and output impedances are considered. The input impedance influences the filters effect on the system displacement power factor and the output impedance plays a key role in the system stability. The effect of filter element values, the number of filter stages as well as additional damping networks are considered and a design procedure is provided. For this analysis a two-port description of the input filters employing ABCD-parameters is used.
Resumo:
El objeto de esta construcción es un Viaducto que permite salvar la carretera de Baños de Arteixo, ofreciendo una continuidad al trazado de la Tercera Ronda y separando el tráfico entre ambas. La Tercera Ronda es una vía de circulación que permite rodear la ciudad de A Coruña, comunicando diferentes zonas de la ciudad y permitiendo la conexión con la AC-552, AG-55 y A-6, desahogando así el tráfico de las principales calles de la ciudad y despejando el centro de la misma. Esta obra supone alcanzar una serie de objetivos generales que se pueden concretar en que constituye una nueva alternativa de circulación gratuita y un acceso rápido y cómodo al Centro Comercial Marineda, a cuantos allí acuden y a todas las empresas y compañías con sus negocios allí instalados.
Resumo:
The maximum performance of bare electrodynamic tethers as power generating systems under OML-theory is analyzed. Results show that best performance in terms of power density is achieved by designing the tether in such a way to increase ohmic impedance with respect to plasma contact impedance, hence favoring longer and thinner tethers. In such condition the corresponding optimal value of the load impedance is seen to approach the ohmic impedance of the conducting tether. At the other extreme, when plasma contact impedance dominates (which is not optimal but can be relevant for some applications) optimum power generation is found by matching the load impedance with an effective tether-plasma contact impedance whose expression is derived.
Resumo:
A new simple concept for electron collection by an electrodynamic tether is presented. No anodic contactor Is needed, the tether itself, left bare, drawing a current with neither shielding nor magnetic effects. Application to a generator is discussed.
Resumo:
The degradation observed on a 7-kWp Si-x photovoltaic array after 17 years of exposure on the roof of the Solar Energy Institute of the Polytechnic University of Madrid is presented. The mean peak power degradation has been 9% over this time, or an equivalent to 0.53% per year, whereas peak power standard deviation has remained constant. The main visual defects are backsheet delamination at the polyester/polyvinyl fluoride outer interface and cracks in the terminal boxes and at the joint between the frame and the laminate. Insulation resistance complies well with the requirements of the International Electrotechnical Commission 61215 tests.
Resumo:
This paper presents the measurement of the I-V curve of a 500-kW PV generator by means of an own-made capacitive load. It is shown that I-V curve analysis can also be applied to big PV generators and that when measuring the operation conditions with reference modules and taking some precautions (especially regarding the operation cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.