3 resultados para polyethylene glycols
em Massachusetts Institute of Technology
Resumo:
Biotinylated and non-biotinylated copolymers of ethylene oxide (EO) and 2-(diethylamino)ethyl methacrylate (DEAEMA) were synthesized by the atom transfer radical polymerization technique (ATRP). The chemical compositions of the copolymers as determined by NMR are represented by PEO₁₁₃PDEAEMA₇₀ and biotin-PEO₁₀₄PDEAEMA₉₃ respectively. The aggregation behavior of these polymers in aqueous solutions at different pHs and ionic strengths was studied using a combination of potentiometric titration, dynamic light scattering (DLS), static light scattering (SLS), and transmission electron microscopy (TEM). Both PEO-b-PDEAEMA and biotin-PEO-b-PDEAEMA diblock copolymers form micelles at high pH with hydrodynamic radii (Rh) of about 19 and 23 nm, respectively. At low pH, the copolymers are dispersed as unimers in solution with Rh of about 6-7 nm. However, at a physiological salt concentration (cs) of about 0.16M NaCl and a pH of 7-8, the copolymers form large loosely packed Guassian chains, which were not present at the low cs of 0.001M NaCl. The critical micelle concentrations (CMC) and the cytotoxicity of the copolymers were investigated to determine a suitable polymer concentration range for future biological applications. Both PEO-b-PDEAEMA and biotin-PEO-b-PDEAEMA diblock copolymers possess identical CMC values of about 0.0023 mg/g, while the cytotoxicity test indicated that the copolymers are not toxic up to 0.05mg/g (> 83% cell survival at this concentration).
Resumo:
BALB/c nude mice 6 weeks old were inoculated with glioma C6 cell-line and the efficacy of the different amount of Etanidazole-discs and Taxol-microspheres was investigated. Poly (D,L-lactic-co-glycolic acid) (PLGA) was used as the main encapsulating polymer and polyethylene glycol was added to increase the porosity. The 1% drug loading microspheres of each drug were produced by spray drying and the discs were obtained by compressing the Etanidazole-microspheres. Intra-tumoral injection followed by irradiation resulted in high systemic dosage and thus systemic toxicity. Tumors grown for 6 days, 9 days and 16 days were implanted with 0.5 mg or 1.0 mg or 1.5 mg of the drug. A radiation dosage of 2 Gy each time for a number of times was given for animals implanted with Etanidazole and no irradiation was given for animals implanted with Taxol. Increasing the number of doses clearly decreased the rate of tumor growth. The increase in the amount of drug on smaller sized tumors controlled the tumor better and there was agglomeration of the microspheres resulting in deviation of release profile of the drug as compared to the in vitro studies. It was observed that 1.0 mg of Taxol given to a tumor grown for 6 days was able to suppress the tumor for a total period of approximately two months and no tumor resurrection was observed during the second month.
The Inertio-Elastic Planar Entry Flow of Low-Viscosity Elastic Fluids in Micro-fabricated Geometries
Resumo:
The non-Newtonian flow of dilute aqueous polyethylene oxide (PEO) solutions through microfabricated planar abrupt contraction-expansions is investigated. The contraction geometries are fabricated from a high-resolution chrome mask and cross-linked PDMS gels using the tools of soft-lithography. The small length scales and high deformation rates in the contraction throat lead to significant extensional flow effects even with dilute polymer solutions having time constants on the order of milliseconds. The dimensionless extra pressure drop across the contraction increases by more than 200% and is accompanied by significant upstream vortex growth. Streak photography and videomicroscopy using epifluorescent particles shows that the flow ultimately becomes unstable and three-dimensional. The moderate Reynolds numbers (0.03 ⤠Re ⤠44) associated with these high Deborah number (0 ⤠De ⤠600) microfluidic flows results in the exploration of new regions of the Re-De parameter space in which the effects of both elasticity and inertia can be observed. Understanding such interactions will be increasingly important in microfluidic applications involving complex fluids and can best be interpreted in terms of the elasticity number, El = De/Re, which is independent of the flow kinematics and depends only on the fluid rheology and the characteristic size of the device.