2 resultados para long night treatment

em Hospitais da Universidade de Coimbra


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Endoscopic injection of N-butyl-2-cyanoacrylate is the current recommended treatment for gastric variceal bleeding. Despite the extensive worldwide use, there are still differences related to the technique, safety, and long term-results. We retrospectively evaluated the efficacy and safety of cyanoacrylate in patients with gastric variceal bleeding. PATIENTS AND METHODS: Between January 1998 and January 2010, 97 patients with gastric variceal bleeding underwent endoscopic treatment with a mixture of N-butyl-2-cyanoacrylate and Lipiodol(TM). Ninety-one patients had cirrhosis and 6 had non-cirrhotic portal hypertension. Child-Pugh score at presentation for cirrhotic patients was A-12.1 %; B-53.8 %; C-34.1 % and median MELD score at admission was 13 (3-26). Successful hemostasis, rebleeding rate and complications were reviewed. Median time of follow up was 19 months (0.5-126). RESULTS: A median mixture volume of 1.5 mL (0.6 to 5 mL), in 1 to 8 injections, was used, with immediate hemostasis rate of 95.9 % and early rebleeding rate of 14.4 %. One or more complications occurred in 17.5 % and were associated with the use of Sengstaken-Blakemore tube before cyanoacrylate and very early rebleeding (p < 0.05). Hospital mortality rate during initial bleeding episode was 9.3 %. Very early rebleeding was a strong and independent predictor for in-hospital mortality (p < 0.001). Long-term mortality rate was 58.8 %, in most of the cases secondary to hepatic failure. CONCLUSION: N-butyl-2-cyanoacrylate is a rapid, easy and highly effective modality for immediate hemostasis of gastric variceal bleeding with an acceptable rebleeding rate. Patients with very early rebleeding are at higher risk of death.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This review evaluates the outcomes of intrastromal corneal ring segment (ICRS) implantation for the treatment of keratoconus considering a new grading system based on the preoperative visual impairment of the patient. Additionally, a five-year follow-up analysis of patients with stable and progressive keratoconus is performed in order to assess the long term stability of the surgical procedure. Corrected distance visual acuity decreased statistically significantly in patients with mild keratoconus (P < 0.01) but statistically significantly increased in all other grades (P < 0.05). The improvement in visual acuity and the decrease of keratometric and aberrometric values were stable throughout a long period of time in patients with stable keratoconus. In patients with progressive form keratoconus, a significant improvement was found immediately after the procedure, however clinically relevant regression greater than 3 D was observed at the end of the follow up period.