4 resultados para Capsule anchor implantation

em Hospitais da Universidade de Coimbra


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The value of capsule endoscopy in the setting of inflammatory bowel disease type unclassified (IBDU) and indeterminate colitis (IC) remains obscure. The aim was to evaluate the clinical impact of capsule endoscopy on IBDU/IC patients with negative serology. METHODS: Eighteen patients with long-standing IBDU (n = 14) and IC (n = 4) were enrolled to undergo a capsule endoscopy and then followed prospectively. Lesions considered diagnostic of Crohn's disease (CD) were 4 or more erosions/ulcers and/or a stricture. The median follow-up time after capsule endoscopy was 32 ± 11 months (23-54 months). RESULTS: Total enteroscopy was possible in all patients. In 2 patients the examination was normal (Group 1). In 9 patients subtle findings were observed (Group 2): focal villi denudation (n = 1) and fewer than 4 erosions/ulcers (n = 8). In 7 patients, 4 or more erosions/ulcers were detected (Group 3), leading to a diagnosis of CD. However, their treatment was not reassessed on the basis of the capsule findings. Until now, a definitive diagnosis has been achieved in 2 additional patients: 1 from Group 1 (ulcerative colitis) and another patient from Group 2 (CD), who began infliximab infusions. Nine patients remained indeterminate at follow-up. CONCLUSIONS: Although capsule endoscopy enabled the diagnosis of CD in 7 patients, in none of them was the clinical management changed. Moreover, a change in therapy due to a diagnosis of CD was made for only 1 patient, who presented nonspecific findings. Our results suggest that capsule findings are not helpful in the work-up of these patients

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: With capsule endoscopy (CE) it is possible to examine the entire small bowel. The present study assessed the diagnostic yield of CE in severe obscure-overt gastrointestinal bleeding (OOGIB). METHODS: During a 3-year period, 15 capsule examinations (4.5% of all CE in a single institution) were carried out in 15 patients (11 men; mean age 69.9 +/- 20.1 years) with severe ongoing bleeding, defined as persistent melena and/or hematochezia, with hemodynamic instability and the need for significant red blood cell transfusion. CE was carried out after non-diagnostic standard upper and lower endoscopy. The mean time from admission until CE was 4.1 +/- 4.4 days (0-15 days). RESULTS: CE revealed active bleeding in seven patients and signs of recent bleeding in four. Etiology of bleeding was correctly diagnosed in 11 patients (73.3%) (portal hypertension enteropathy, three patients; subepithelial ulcerated lesion, two patients; angiodysplasia, two patients; jejunal ulcer with visible vessel, one patient; multiple small bowel ulcers, one patient; jejunal tumor, one patient; jejunal mucosa irregularity with adherent clot, one patient). One patient (6.7%) had active bleeding but no visible lesion. As a consequence of the capsule findings, specific therapeutic measures were undertaken in 11 patients (73.3%) with five managed conservatively, four endoscopically and two surgically. Two patients experienced bleeding recurrence. One of them, with a probable small bowel tumor, refused any other interventions. CONCLUSIONS: CE is useful in patients with severe OOGIB by providing positive findings in the majority of patients, with subsequent impact on therapeutic procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical utility of prokinetics in capsule endoscopy (CE) is not clearly established. The objective of this prospective, randomized, single-blind, controlled trial was to determine if metoclopramide is useful in CE by increasing the rate of complete enteroscopy. Ninety-five patients referred for CE were randomized to no metoclopramide (group B, n = 48) or 10 mg metoclopramide (group A, n = 47). Complete enteroscopy was possible in 38 patients of group A (80.9%) and 37 of group B (77.1%) (P = 0.422) with two cases of gastric retention in group B (4.2%; P = 0.253). Median gastric transit time was 26 min (1-211) in group A and 28 min (4-200) in group B (P = 0.511). Mean small bowel transit time, calculated after excluding 20 patients with incomplete enteroscopy, was similar in both groups (221.2 +/- 89 min vs. 256 +/- 82.2 min; P = 0.083). There were also no differences in the total number of findings (group A 4.5 +/- 4.7; group B 4.7 +/- 3.7, P = 0.815). Administration of 10 mg metoclopramide orally 15 min before capsule ingestion did not significantly increase the rate of total enteroscopies and had no effect on transit times. It also did not modify CE diagnostic yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.