2 resultados para Increasing hazard ratio

em RCAAP - Repositório Científico de Acesso Aberto de Portugal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Malignant ascites is debilitating for patients with advanced cancer. As shown previously, tumour cell production of vascular endothelial growth factor might be a major cause of the formation of malignant ascites. Intraperitoneal bevacizumab could therefore be an option for symptom control in refractory ascites. PATIENTS AND METHODS: Patients with advanced gastrointestinal cancer and malignant ascites who had undergone paracentesis at least twice within the past 4 weeks were randomly assigned in a 2:1 ratio to intraperitoneal bevacizumab (400 mg absolute) or placebo after paracentesis. During the 8-week treatment period, a minimum interval of 14 d was kept between the applications of the study drug. Primary end-point was paracentesis-free survival (ParFS). RESULTS: Fifty-three patients (median age 63 years) were randomised. Forty-nine patients received at least one study drug application and qualified for the main analysis. The proportion of patients with at least one common toxicity criteria grade III-V event was similar with 20/33 (61%) on bevacizumab and 11/16 (69%) on placebo. Median ParFS was 14 d (95% confidence interval [CI]: 11-17) in the bevacizumab arm and 10.5 d (95% CI: 7-21) on placebo (hazard ratio 0.74, 95% CI: 0.40-1.37; P = 0.16). The longest paracentesis-free period was 19 d on bevacizumab (range 6-66 d) and 17.5 d in the placebo arm (range 4-42) (P = 0.85). Median overall survival was 64 d (95% CI: 45-103) on bevacizumab compared to 31.5 d (95% CI: 20-117) on placebo (P = 0.31). CONCLUSION: Intraperitoneal bevacizumab was well tolerated. Overall, treatment did not result in a significantly better symptom control of malignant ascites. However, patients defined by specific immune characteristics may benefit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of the image of 18F-FDG PET/CT scans in overweight patients is commonly degraded. This study evaluates, retrospectively, the relation between SNR, weight and dose injected in 65 patients, with a range of weights from 35 to 120 kg, with scans performed using the Biograph mCT using a standardized protocol in the Nuclear Medicine Department at Radboud University Medical Centre in Nijmegen, The Netherlands. Five ROI’s were made in the liver, assumed to be an organ of homogenous metabolism, at the same location, in five consecutive slices of the PET/CT scans to obtain the mean uptake (signal) values and its standard deviation (noise). The ratio of both gave us the Signal-to- Noise Ratio in the liver. With the help of a spreadsheet, weight, height, SNR and Body Mass Index were calculated and graphs were designed in order to obtain the relation between these factors. The graphs showed that SNR decreases as the body weight and/or BMI increased and also showed that, even though the dose injected increased, the SNR also decreased. This is due to the fact that heavier patients receive higher dose and, as reported, heavier patients have less SNR. These findings suggest that the quality of the images, measured by SNR, that were acquired in heavier patients are worst than thinner patients, even though higher FDG doses are given. With all this taken in consideration, it was necessary to make a new formula to calculate a new dose to give to patients and having a good and constant SNR in every patient. Through mathematic calculations, it was possible to reach to two new equations (power and exponential), which would lead to a SNR from a scan made with a specific reference weight (86 kg was the considered one) which was independent of body mass. The study implies that with these new formulas, patients heavier than the reference weight will receive higher doses and lighter patients will receive less doses. With the median being 86 kg, the new dose and new SNR was calculated and concluded that the quality of the image remains almost constant as the weight increases and the quantity of the necessary FDG remains almost the same, without increasing the costs for the total amount of FDG used in all these patients.