3 resultados para CT scan

em RCAAP - Repositório Científico de Acesso Aberto de Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 66-year-old female with history of endometrioid endometrial carcinoma was admitted to our institution with abdominal and pelvic pain. A CT scan revealed a mass within the right upper kidney with a tumour thrombus that extended through the right renal vein up to the point of confluence with the inferior vena cava (IVC). The imaging features of the mass strongly suggested a diagnosis of renal angiomyolipoma (AML) with renal vein thrombosis. The patient was proposed an open radical right nephrectomy with right renal thrombectomy for histopathological confirmation of the diagnosis of AML with extension to the right renal vein and preventing complications such as potentially fatal pulmonary thromboembolism. The implantation of a temporary IVC filter before surgery was recommended.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a case of a 5th Lumbar Vertebra (L5) spinous process osteochondroma as a rare cause of lumbar pain in an old patient. A 70-year-old male presented with progressive and disabling lower lumbar pain. Tenderness over the central and left paraspinal area of the lower lumbar region and a palpable mass were evident. CT scan showed a mass arising from the spinous process of L5. Marginal resection of the tumor was performed through a posterior approach. The histological study revealed an osteochondroma. After surgery, pain was completely relieved. After one year there was no evidence of local recurrence or symptoms. Osteochondromas rarely involve the spine, but when they do symptoms like pain, radiculopathy/myelopathy, or cosmetic deformity may occur. The imagiologic exam of election for diagnosis is CT scan. When symptomatic the treatment of choice is surgical resection. The most concerning complication of osteochondromas is malignant transformation, a rare event.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of the image of 18F-FDG PET/CT scans in overweight patients is commonly degraded. This study evaluates, retrospectively, the relation between SNR, weight and dose injected in 65 patients, with a range of weights from 35 to 120 kg, with scans performed using the Biograph mCT using a standardized protocol in the Nuclear Medicine Department at Radboud University Medical Centre in Nijmegen, The Netherlands. Five ROI’s were made in the liver, assumed to be an organ of homogenous metabolism, at the same location, in five consecutive slices of the PET/CT scans to obtain the mean uptake (signal) values and its standard deviation (noise). The ratio of both gave us the Signal-to- Noise Ratio in the liver. With the help of a spreadsheet, weight, height, SNR and Body Mass Index were calculated and graphs were designed in order to obtain the relation between these factors. The graphs showed that SNR decreases as the body weight and/or BMI increased and also showed that, even though the dose injected increased, the SNR also decreased. This is due to the fact that heavier patients receive higher dose and, as reported, heavier patients have less SNR. These findings suggest that the quality of the images, measured by SNR, that were acquired in heavier patients are worst than thinner patients, even though higher FDG doses are given. With all this taken in consideration, it was necessary to make a new formula to calculate a new dose to give to patients and having a good and constant SNR in every patient. Through mathematic calculations, it was possible to reach to two new equations (power and exponential), which would lead to a SNR from a scan made with a specific reference weight (86 kg was the considered one) which was independent of body mass. The study implies that with these new formulas, patients heavier than the reference weight will receive higher doses and lighter patients will receive less doses. With the median being 86 kg, the new dose and new SNR was calculated and concluded that the quality of the image remains almost constant as the weight increases and the quantity of the necessary FDG remains almost the same, without increasing the costs for the total amount of FDG used in all these patients.