5 resultados para air contamination

em Instituto Nacional de Saúde de Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in one Portuguese maternity. Sixty air samples were collected through impaction method. Air sampling was performed in food storage facilities, kitchen, food plating, canteen, pharmacy, sterilization areas, genecology wards, intensive care unit, operating rooms, urgency and also, outside premises, since this was the place regarded as reference. Besides air samples, forty three samples were collected by swabbing the surfaces using a 10 by 10 cm square stencil. Simultaneously, temperature, relative humidity and particles counting (PM10) were registered. Twenty three species of fungi were identified in air, being the two most commonly isolated the genera Penicillium (41,5%) and Cladosporium (28,4%). Regarding yeasts, only Rhodotorula sp. (45,2%), Trichosporon mucoides (51,6%) and Cryptococcus neoformans (3,2%) were found. Thirteen species of fungi were identified in surfaces, being the most frequent the Penicillium genus (91,6%). Concerning yeasts found in surfaces, four species were identified being Rhodotorula sp. (29,1%) the most frequent. There was no coincidence between prevailing genera indoors and outside premises. Moreover, some places presented fungal species different from the ones isolated outside. In the inside environment, Aspergillus species were isolated in air and surfaces. There was no significant relationship (p>0,05) between fungal contamination and the studied environmental variables. Keywords: air, surfaces, fungal contamination, environmental variables, maternity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A descriptive study was developed to compare air and surfaces fungal contamination in ten hospitals’ food units and two food units from companies. Fifty air samples of 250 litres through impaction method were collected from hospitals’ food units and 41 swab samples from surfaces were also collected, using a 10 by 10 cm square stencil. Regarding the two companies, ten air samples and eight surface samples were collected. Air and surface samples were collected in food storage facilities, kitchen, food plating and canteen. Outdoor air was also collected since this is the place regarded as a reference. Simultaneously, temperature, relative humidity and meal numbers were registered. Concerning air from hospitals’ food units, 32 fungal species were identified, being the two most commonly isolated genera Penicillium sp.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study developed in order to know the carpet influence when used in the floor of a hotel room. Twelve air samples of 250L (six in a room with carpet and six more in a room with wood floor) were collected through an impaction method with a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore), during cleaning activities. Outdoor sample was also performed to be used as a reference. Surface samples from floor and desks, taken at the same time, were collected by the swabbing method. to 7 days. Besides fungal contamination, we also assessed particulate matter contamination in both rooms during the same cleaning tasks. In the analyzed sur- faces, isolates belonging to Aspergillus fumigatus complex were the only fungi found in the carpeted room, whereas in the other room we found Penicllium sp. (63.6%) and Aspergillus sp. (13.6%) as the most frequent genera. In the case of particles the room with carpet obtained significant higher values for both metrics (PMC and PNC), showing that carpet may has influence on particles’ contamination of the room.