3 resultados para Repetitive-element-based PCR assays

em Instituto Nacional de Saúde de Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a dataset proving the simultaneous presence of a 5′UTR-truncated PDHA1 mRNA and a full-length PDHA2 mRNA in the somatic cells of a PDC-deficient female patient and all members of her immediate family (parents and brother). We have designed a large set of primer pairs in order to perform detailed RT-PCR assays allowing the clear identification of both PDHA1 and PDHA2 mRNA species in somatic cells. In addition, two different experimental approaches were used to elucidate the copy number of PDHA1 gene in the patient and her mother. The interpretation and discussion of these data, along with further extensive experiments concerning the origin of this altered gene expression and its potential therapeutic consequences, can be found in “Complex genetic findings in a female patient with pyruvate dehydrogenase complex deficiency: null mutations in the PDHX gene associated with unusual expression of the testis-specific PDHA2 gene in her somatic cells” (A. Pinheiro, M.J. Silva, C. Florindo, et al., 2016).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diagnostic techniques based on PCR have two major problems: false-positive reactions due to contamination with DNA fragments from previous PCRs (amplicons) and false-negative reactions caused by inhibitors that interfere with the PCR. We have improved our previously reported PCR based on the amplification of a fragment of the Mycobacterium tuberculosis complex-specific insertion element IS6110 with respect to both problems. False-positive reactions caused by amplicon contamination were prevented by the use of uracil-N-glycosylase and dUTP instead of dTTP. We selected a new set of primers outside the region spanned by the formerly used primers to avoid false-positive reactions caused by dTTP-containing amplicons still present in the laboratory. With this new primer set, 16 copies of the IS6110 insertion element, the equivalent of two bacteria, could be amplified 10(10) times in 40 cycles, resulting in a mean efficiency of 77% per cycle. To detect the presence of inhibitors of the Taq polymerase, which may cause false-negative reactions, part of each sample was spiked with M. tuberculosis DNA. The DNA purification method using guanidinium thiocyanate and diatoms effectively removed most or all inhibitors of the PCR. However, this was not suitable for blood samples, for which we developed a proteinase K treatment followed by phenol-chloroform extraction. This method permitted detection of 20 M. tuberculosis bacteria per ml of whole blood. Various laboratory procedures were introduced to reduce failure or inhibition of PCR and avoid DNA cross contamination. We have tested 218 different clinical specimens obtained from patients suspected of having tuberculosis. The samples included sputum (n=145), tissue biopsy samples (n=25), cerebrospinal fluid (n=15), blood (n=14), pleural fluid (n=9), feces, (n=7), fluid from fistulae (n=2), and pus from a wound (n=1). The results obtained by PCR were consistent with those obtained with culture, which is the "gold standard." We demonstrate that PCR is a useful technique for the rapid diagnosis of tuberculosis at various sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento em Biologia apresentada à Faculdade de Ciências da Universidade do Porto, 2015.